MICHAEL J. WITTE 1 AND CHRISTIAN G. PARIGGER 1,a

Similar documents
DIAGNOSTIC OF A LASER-INDUCED OPTICAL BREAKDOWN BASED ON HALF-WIDTH AT HALF AREA OF H LINES , H , AND H

Aluminum Monoxide Emission Measurements Following Laser-Induced Breakdown for Plasma Characterization

Quantitative Analysis of Carbon Content in Bituminous Coal by Laser-Induced Breakdown Spectroscopy Using UV Laser Radiation

Measurements of plasma temperature and electron density in laser-induced copper plasma by time-resolved spectroscopy of neutral atom and ion emissions

I R A M P 3(1), June 2012, pp

Differential Spectral Imaging of the CN Violet Band in Laser-Induced Plasmas on TNT Simulant Molecules

Time-Resolved Emission Spectroscopic Study of Laser-Induced Steel Plasmas

Measurements of egg shell plasma parameters using laser-induced breakdown spectroscopy

CARBON DIOXIDE SPLITTING INTO CARBON MONOXIDE AND OXYGEN USING ATMOSPHERIC ELECTRODELESS MICROWAVE PLASMA

Fine structure in the time of flight distribution of C2 in laser produced plasma from graphite

LIBSlab ANALYZERS ANALYZERS

Characterisation & Use of Array Spectrometers

Because light behaves like a wave, we can describe it in one of two ways by its wavelength or by its frequency.

Optical Emission Studies of a Plume Produced by Laser Ablation of a Graphite Target in a Nitrogen Atmosphere

Use of a High-Resolution Overview Spectrometer for the Visible Range in the TEXTOR Boundary Plasma

Underwater Raman Sensor for Detecting High Explosives and Homemade Explosives (HMEs)

Expansion dynamics of laser ablated carbon plasma plume in helium ambient

Experiment 4 Radiation in the Visible Spectrum

I R A M P 7(1), June 2016, pp

Title duration on laser ablation in liqui. Rightc 2009 Elsevier B.V. All rights res

Atomic Spectroscopy. Absorption and Emission Spectra. Lodovico Lappetito. SpettroscopiaAtomica - 15/07/2015 Pag. 1

Laser heating of noble gas droplet sprays: EUV source efficiency considerations

ARC SPECTRUM OF IRON /COPPER / BRASS

University of Cyprus. Reflectance and Diffuse Spectroscopy

High resolution optogalvanic spectrum of N2-rotational structure of (11, 7) band in the first positive system

Visualization of Xe and Sn Atoms Generated from Laser-Produced Plasma for EUV Light Source

Plasma Temperature Measurements in the Context of Spectral Interference

Lead and Arsenic concentration in the Marseille Calanques measured by Laser Induced Breakdown Spectroscopy. by T. Sarnet and J.

Investigation of fundamental mechanisms related to ambient gas heating and hydrodynamics of laser-induced plasmas

ablation Batikan Koroglu, Harry B. Radousky, Joseph M. Zaug, Michael R. Armstrong, Brett H. Isselhardt, Michael R. Savina

Any first year text, sections on atomic structure, spectral lines and spectrometers

Lab 11: Must what goes in be the same as what comes out? Spectroscopy & Fluorescence in Chlorophyll.

Lab VI Light Emitting Diodes ECE 476

Laser-produced extreme ultraviolet (EUV) light source plasma for the next generation lithography application

Measurements of Ionization Potentials with Laser-induced Plasma Spectroscopy International Science Press ISSN:

Laser Induced Fluorescence of Iodine

APAS Laboratory { PAGE } Spectroscopy SPECTROSCOPY

n ( λ ) is observed. Further, the bandgap of the ZnTe semiconductor is

Generation of high-temperature and low-density plasmas for improved spectral resolutions in laser-induced breakdown spectroscopy

Rejection of Recombination and Electron Collision Process in the Laser Plasma Generated by the Nd-YAG Laser Irradiation at Low Pressures

Laser Ablation for Chemical Analysis: 50 Years. Rick Russo Laser Damage Boulder, CA September 25, 2012

high temp ( K) Chapter 20: Atomic Spectroscopy

Vibrational Spectra of Chloroform, Freon-11 and Selected Isotopomers in the THz Frequency Region

EMISSION SPECTROSCOPY

Spatial analysis of C 2 band emission from laser produced plasma

PAPER No. 12: ORGANIC SPECTROSCOPY MODULE No. 7: Instrumentation for IR spectroscopy

The relationship between these aspects is described by the following equation: E = hν =

Mechanisms of Visible Photoluminescence from Size-Controlled Silicon Nanoparticles

Dynamics of carbon and tungsten colliding plumes

CHEM*3440. Photon Energy Units. Spectrum of Electromagnetic Radiation. Chemical Instrumentation. Spectroscopic Experimental Concept.

LABORATORY OF ELEMENTARY BIOPHYSICS

Spectroscopic Studies of Soft X-Ray Emission from Gadolinium Plasmas

Laser Raman Spectroscopy: Vibrational Spectrum of CCl 4

Richard Miles and Arthur Dogariu. Mechanical and Aerospace Engineering Princeton University, Princeton, NJ 08540, USA

Thermodynamic evolution of phase explosion during high-power nanosecond laser ablation

Chem Homework Set Answers

Evaluation of laser-induced breakdown spectroscopy (LIBS) as a new in situ chemical sensing technique for the deep ocean

Atomic Spectroscopy. Objectives

Set-up for ultrafast time-resolved x-ray diffraction using a femtosecond laser-plasma kev x-ray-source

The Emission Spectra of Light

Atomic Spectra. d sin θ = mλ (1)

Glass surface modification using Nd:YAG laser in SF 6 atmospheres

LASER-COMPTON SCATTERING AS A POTENTIAL BRIGHT X-RAY SOURCE

Observation of Atomic Spectra

Resonance Raman measurements utilizing a deep UV source

X-Rays From Laser Plasmas

The importance of longer wavelength reheating in dual-pulse laser-induced breakdown spectroscopy

Chem 310 rd. 3 Homework Set Answers

Measured Stark shifts of Kr I line profiles in the 5s 5p and 5s 5p transitions

LIDAR. Natali Kuzkova Ph.D. seminar February 24, 2015

Pre-lab Quiz/PHYS 224. Your name Lab section

ATOMIC SPECTRA. To identify elements through their emission spectra. Apparatus: spectrometer, spectral tubes, power supply, incandescent lamp.

Internal magnetic field measurement in tokamak plasmas using a Zeeman polarimeter

( J s)( m/s)

Two-electron systems

Emission characteristics and dynamics of C 2 from laser produced graphite plasma

OPTICAL DETECTION OF SLOW EXCITED NEUTRALS IN PLASMA- ASSISTED EXCIMER LASER ABLATION

EUV Reflectivity measurements on Acktar Sample Magic Black

Pizza Box Spectrometer Data & Report

Spectral analysis of K-shell X-ray emission of magnesium plasma produced by ultrashort high-intensity laser pulse irradiation

Laser Dissociation of Protonated PAHs

Chem 155 Midterm Exam Page 1 of 10 Spring 2010 Terrill

Practical 1P4 Energy Levels and Band Gaps

Electron temperature is the temperature that describes, through Maxwell's law, the kinetic energy distribution of the free electrons.

DIFFRACTION GRATING. OBJECTIVE: To use the diffraction grating in the formation of spectra and in the measurement of wavelengths.

Dynamics of a laser-assisted Z-pinch EUV source

Practical 1P4 Energy Levels and Band Gaps

Fundamental investigation on CO 2 laser-produced Sn plasma for an EUVL source

Laser-induced plasma electron number density: Stark broadening method versus the Saha Boltzmann equation

Stray Light Rejection in Array Spectrometers

Influence of laser energy on the electron temperature of a laser induced Mg plasma

Development of optimized Raman Spectroscopy setup for species detection in flames

Magnetic Assisted Laser Micromachining for Highly Reflective Metals

INTRODUCTION Atomic fluorescence spectroscopy ( AFS ) depends on the measurement of the emission ( fluorescence ) emitted from gasphase analyte atoms

Photoelectric Effect Experiment

Plasma Radiation. Ø Free electrons Blackbody emission Bremsstrahlung

Dense plasma formation on the surface of a ferroelectric cathode

Direct measurement of spectral phase for ultrashort laser pulses

Introduction to FT-IR Spectroscopy

Answers to questions on exam in laser-based combustion diagnostics on March 10, 2006

Transcription:

I R A M P Measurement and Analysis of Carbon Swan Spectra Following Laser-induced Optical Breakdown International in AirScience Press ISSN: 2229-3159 4(1), June 2013, pp. 63-67 Measurement and Analysis of Carbon Swan Spectra Following Laser-induced Optical Breakdown in Air MICHAEL J. WITTE 1 AND CHRISTIAN G. PARIGGER 1,a 1 University of Tennessee Space Institute, Center for Laser Applications, Tullahoma, TN 37388, USA a Corresponding author: cparigge@tennessee.edu ABSTRACT: In this work, we report on measurements of time-resolved Carbon Swan spectra following laser ablation of carbon material. Diatomic molecular C 2 line-strengths are utilized to compute the fitting of the measured data. The C 2 molecule shows that its lowest rotational levels are sensitive to temperature variation. However, we record spectra for time delays for which Local Thermodynamic Equilibrium is expected to be established. In this respect, a single temperature fitting will be viable. For laser ablation of graphene with 190 millijoule, 13 nanosecond Nd:YAG pulses at a wavelength of 1064 and 532 nanometers, our results show temperatures in the range of 4000 to 6500 K for delays in the range of 70 to 20 microseconds after optical breakdown. PACS numbers: 52.50.Jm, 33.20.-t, 78.47.dc, 82.80.-d, 95.55Qf, 95.75.Fg. Keywords: laser-induced breakdown spectroscopy; molecular spectroscopy, time- resolved spectroscopy, laser-induced breakdown, spectroscopy in astronomy. I. INTRODUCTION Laser-induced breakdown spectroscopy (LIBS) can be applied for accurate determination of unknown materials. When faced with an unknown material, direct handling of the material may not be desired, usually due to concerns of the material being radioactive, unstably explosive, or other such hazards. Most of these substances contain carbon compounds. LIBS offers a mostly non-invasive way in looking at the materials spectrum to analyze its composition. In order for this procedure to be effective, a reasonable set of precise and accurate calibration spectra is preferably available or must be acquired. In other words, precision and accuracy are required. Thus, for applications of LIBS with carbon compounds, experiments that address C 2 molecular spectra are desirable together with an accurate analysis. Spectral predictions for diatomic molecules require at least a temperature to determine Boltzmann factors and line-strengths that represent the allowed spectral transitions for the molecule 1. Atomic and molecular spectroscopy techniques 2 allow us to analyze recorded spectra. However, accurate spectral predictions may also include spectral resolution, electron density, reaction rates, collision rates, and pressure. These parameters are adjusted to determine the best fitting model for each spectral measurement. In this investigation, we infer the temperature of C 2 Swan bands for laser ablation events by comparing measured with computed spectra. II. EXPERIMENTAL ARRANGEMENT Frequency doubled laser radiation on the order of 75 mj/pulse is used to generate laser-induced breakdown. The pulse width of the laser radiation amounted to 13 ns, and measurements utilized varying gate widths corresponding to varying time delays ranging from 20 µs to 70 µs, with gate width times increased as needed. The time-resolved spectra were recorded with a EG&G PARC linear diode array to record spectra dispersed with a 1800 grooves/mm grating in a HR640 Jobin-Yvon 0.6 m spectrometer. Sensitivity calibration was accomplished by use of a tungsten International Review of Atomic and Molecular Physics, 4 (1), January-June 2013 63

Michael J. W itte and Christian G. Parigger Figure 1: Photographs of experimental arrangement. Top part shows the Nd:YAG laser (bottom left). Bottom part shows the spectrograph (middle left). standard lamp, measured at an operating temperature of 2910 K. Wavelength calibration was accomplished with a mercury lamp. Figure 1 shows a photograph of the experimental setup. The carbon sample is either manually held or placed on an angled surface, depending on which allowed the best collection of data. The 532-nm laser radiation is focused onto the sample, ablating it, and the plasma emission is imaged onto the spectrometer entrance slit on the right. III. RESULTS The experimental procedures included capture of time-resolved spectra for various time delays, followed by intensity and wavelength calibration. The intensity calibration uses a standard black-body curve calculated for the spectral wavelength band and the recorded intensity profile emitted by a tungsten lamp. The calibration is accomplished using a least-squares algorithm. Analysis of the experimental records is accomplished by sequentially increasing the accuracy of the comparisons of experimentally recorded and computed molecular spectra. The Calibrated spectra are fit with the predicted C2 spectra using a Nelder-Mead algorithm, which allows multi-variable fitting. Intensity- and wavelengthcalibrated data are run through the so-called Nelder-Mead-Temperature (NMT) program with, first, a fixed FWHM of 0.08 nm. A spectral fit is generated, which is used to linearly wavelength calibrate the data. This generates a new spectrum, allowing a repeat of the process, though with quadratic wavelength fitting this time. Subsequently, the FWHM is set to variable and a new fit is computed. This is followed by generating a cubic wavelength fit. The NMT program is then utilized three times to compute the temperature that generates the best fit between the experimental and theory spectra. This procedure is applied for both the 504-517 nm and the 550-564 nm wavelength bands. 64 International Review of Atomic and Molecular Physics, 4 (1), January-June 2013

Measurement and Analysis of Carbon Swan Spectra Following Laser-induced Optical Breakdown in Air Figure 2: C 2 spectra, with a delay of 30 µs and a gate-width of 1 µs. Calculated temperature amounts to 4300 K, with a spectral resolution FWHM of 0.086 nm. This graph shows the experimental and the superposed computed spectrum. The curved line indicates the background. The bottom spectrum illustrates the difference between the experimental and fitted data. The difference data shows a standard deviation of 175, the background curve average amounts to 448. Figure 2 is a representative display of recorded and fitted C 2 spectra for the C 2 550-564 nm wavelength band. As discussed in Refs. 1,8, carbon shows four band transitions between 550 and 564 nm: (0-1), (1-2), (2-3), and (3-4) bands. The four expected C 2 peaks, the C 2 = 1 Swan band sequences, are visible : two prominent (558.5 nm, 563.5 nm), two not so prominent (550.1 nm, 554.0 nm). The experimental data shows nice agreement with the fitted spectra as they nearly overlap. The difference graphs show an average near zero, with standard deviations below the background averages. The spikes coincide around the C 2 peaks. Figure 3 shows C 2 data for the 504-517 nm bands. The double Swan peaks appear nicely, and the computed spectra line up with the experimental data. The figure also illustrates a near-straight background determined in the fitting procedure. The difference of experiment and computed spectra is shown as well. Figure 4 displays the temperatures for the 550-564 nm wavelength range. For the early time delay, the temperature amounts to 4400 K and demonstrates a slow downward trend with increasing delay times. Fig. 4 also displays results for the 504-517 nm band. The temperature amounts to 6000 K and shows a moderate decrease, though with a dip near 60 µs delay. We further investigated the background a nd the standard deviation(std) of the differ ence between the experimental data and computed spectrum. We find that the 550-564 nm band shows consistently lower STD, while the 504-517 nm band has STD near equal levels to background noise but in one case slightly exceeds it. International Review of Atomic and Molecular Physics, 4 (1), January-June 2013 65

Michael J. Witte and Christian G. Parigger Figure 3: C 2 spectra, with a delay of 20 µs and a gate of 1 µs. Calculated temperature amounts to 6000 K, with a FWHM of 0.096 nm. This graph shows the experimental and the superposed computed spectrum. Below is the background curve and then the difference between the experimental and fitted data. The difference data has a standard deviation of 364, and the background curve average amounts to 442. Figure 4: Shows temperatures at various delays for each bandwidth. Notable is the difference in temperatures and that solitary dip. 66 International Review of Atomic and Molecular Physics, 4 (1), January-June 2013

Measurement and Analysis of Carbon Swan Spectra Following Laser-induced Optical Breakdown in Air IV. CONCLUSIONS Throughout most of the measurements, results have been within expected parameter ranges for temperature, background, and spectral resolution. However, there have been some discrepancies. As seen in figure 4, two major ones are the differences in temperatures between the two bands, and the dip at 60 µs for the 504-517 band. There can be several reasons for the differences. For example, differences can be due to volume-averaging over time, as the laser-induced plasma is recorded over a range of 20 to 70 microseconds time delays after micro-plasma generation during laser ablation with gate widths on the order of 1-10 µs. In addition, the plasma is volume-averaged over space as the linear diode array only allows for a one-dimensional spectrum. This is partially mitigated by the difference graph which can help reinforce the agreement between experiment and theory, and indicate a lower bounds for significant results. Future experimental studies show two main interests. One, increase in spectral resolution by employing a higher grooves/mm grating to possibly address some of the differences in inferred temperature. Two, recording of spatially resolved data will be of interest possibly followed by application of Abel and Radon inverse transformations in order to better study the discrepancies that are indicated. Acknowledgements MJW and CGP thank for support of this work by the Center for Laser Applications at the University of Tennessee Space Institute. References [1] J. O. Hornkohl, L. Nemes, and C.G. Parigger, Spectroscopy of Carbon Containing Diatomic Molecules, in Spectroscopy, Dynamics and Molecular Theory of Carbon Plasmas and Va- pors, Advances in the Understanding of the Most Complex High-Temperature Elemental System, L. Nemes and S. Irle, Eds. (World Scientific), 113-169 (2011). [2] C.G. Parigger, and J.O. Hornkohl, Int. Rev. At. Mol. Phys. 1, 25, (2010). [3] C. G. Parigger, Spectrochim. Acta B 79-80, 4, (2013). [4] V. Motto-Ros, Q.L. Ma, S. Gregoire, W.Q. Lei, X.C. Wang, F. Pelascini, F. Surma, V. Detalle, J. Yu, Spectrochim. Acta B 74-75, 11 (2012). [5] V. K. Unnikrishnan, Kamlesh Alti, Ra jesh Nayak, Rodney Bernard, V. B. Kartha, C. Santhosh, G. P. Gupta, and B. M. Suri, Pramana - J. Phys. 75, 1145, (2010). [6] S. S. Harilal, R. C. Issac, C. V. Bindhu, V. P N. Nampoori, C. P. G. Vallabhan, J. Phys. D: Appl. Phys. 30, 1703, (1997). [7] E. Rohlfing, J. Chem. 89, 6103, (1988). [8] Abhilasha and R.K. Thareja, Phys. Lett. A 184, 99, (1993). International Review of Atomic and Molecular Physics, 4 (1), January-June 2013 67