Nontarget Analysis via LC-QTOF-MS to Assess the Release of Organic Substances from Polyurethane Coating

Similar documents
Overview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada)

Overview. Introduction. André Schreiber 1 and Yun Yun Zou 1 1 AB SCIEX, Concord, Ontario, Canada

PesticideScreener. Innovation with Integrity. Comprehensive Pesticide Screening and Quantitation UHR-TOF MS

Application Note LCMS-116 What are we eating? MetaboScape Software; Enabling the De-replication and Identification of Unknowns in Food Metabolomics

Making Sense of Differences in LCMS Data: Integrated Tools

RMassBank: Automatic Recalibration and Processing of Tandem HR-MS Spectra for MassBank

Application Note. Edgar Naegele. Abstract

Proposal: criteria for positive identification in LC-MS analysis

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

Application Note LCMS-112 A Fully Automated Two-Step Procedure for Quality Control of Synthetic Peptides

Rapid and Accurate Forensics Analysis using High Resolution All Ions MS/MS

AB SCIEX SelexION Technology Used to Improve Mass Spectral Library Searching Scores by Removal of Isobaric Interferences

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

Metabolomic Profiling of Accurate Mass LC-MS/MS Data to Identify Unexpected Environmental Pollutants

MassHunter TOF/QTOF Users Meeting

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

Quantitation of High Resolution MS Data Using UNIFI: Acquiring and Processing Full Scan or Tof-MRM (Targeted HRMS) Datasets for Quantitative Assays

Application Note. David A. Weil Zoltan Timar Michael Zumwalt Edgar Naegele. Abstract

Determination of Beta-Blockers in Urine Using Supercritical Fluid Chromatography and Mass Spectrometry

Multi-residue analysis of pesticides by GC-HRMS

WADA Technical Document TD2003IDCR

SUSPECT AND NON-TARGET SCREENING OF ORGANIC MICROPOLLUTANTS IN WASTEWATER THROUGH THE DEVELOPMENT OF A LC-HRMS BASED WORKFLOW

Key Features of Targeted Metabolite Screening. Using the TripleTOF System, an Accurate Mass Metabolite Spectral Library and MasterView Software

Supporting Information

5Cl-AKB48 and 5Br-AKB48

Achieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer

Profiling of Diferulates (Plant Cell Wall Cross- Linkers) Using Ultrahigh-performance Liquid. Chromatography-Tandem Mass Spectrometry

TargetScreener. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS

Identification and Characterization of an Isolated Impurity Fraction: Analysis of an Unknown Degradant Found in Quetiapine Fumarate

Quantitative Analysis and Identification of Migrants in Food Packaging Using LC-MS/MS

NEW TOOLS FOR FINDING AND IDENTIFYING METABOLITES IN A METABOLOMICS WORKFLOW

A Workflow Approach for the Identification and Structural Elucidation of Impurities of Quetiapine Hemifumarate Drug Substance

Applying MRM Spectrum Mode and Library Searching for Enhanced Reporting Confidence in Routine Pesticide Residue Analysis

Supporting Information. Sweetened Swimming Pools and Hot Tubs

Low-level Determination of 4-Hydrazino Benzoic Acid in Drug Substance by High Performance Liquid Chromatography/Mass Spectrometry

N-(1-carbamoyl-2-methyl-propyl)-1-(5-chloropentyl)indazole-3- carboxamide

Methyl 1-[(4-fluorophenyl)methyl]indazole-3-carboxylate

Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS

De Novo Metabolite Chemical Structure Determination. Paul R. West Ph.D. Stemina Biomarker Discovery, Inc.

The Agilent 1260 Infinity Analytical SFC System with Time-of-Flight Mass Spectrometric Detection

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

Quantitative analysis of mitragynine in human urine by high performance liquid chromatography-tandem mass spectrometry

All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

2-[[2-(4-ethyl-2,5-dimethoxy-phenyl)ethylamino]methyl]phenol

Toxicity, Teratogenic and Estrogenic Effects of Bisphenol A and its Alternative. Replacements Bisphenol S, Bisphenol F and Bisphenol AF in Zebrafish.

Analysis of Pharmaceuticals and Personal Care Products in River Water Samples by UHPLC-TOF

The new Water Screening PCDL

Analysis of Polar Metabolites using Mass Spectrometry

Agilent ESI and APCI sources: for polar to non-polar compounds

Food & Environmental. Overview. Introduction. Method Details. André Schreiber and Yun Yun Zou SCIEX, Concord, Ontario, Canada

Identifying Disinfection Byproducts in Treated Water

4-methyl-1-phenyl-2-pyrrolidin-1-yl-pentan-1-one

Untargeted Screening on the X500R QTOF

WADA Technical Document TD2015IDCR

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity

Separation of Enantiomers of Amphetamine-Related Drugs and Their Structural Isomers

Mass Spectrometry. Hyphenated Techniques GC-MS LC-MS and MS-MS

4-Methyldiethcathinone (4-MDEC)

Technical Procedure for Blood Cannabinoid Liquid-Liquid Extraction (BCLLE) for Analysis by LC-MS/MS

1-(1,3-benzodioxol-5-yl)-2-(ethylamino)hexan-1-one

Key Words Q Exactive, Accela, MetQuest, Mass Frontier, Drug Discovery

Welcome! Course 7: Concepts for LC-MS

A Rapid Approach to the Confirmation of Drug Metabolites in Preclinical and Clinical Bioanalysis Studies

Extraction of Aflatoxins and Ochratoxin from Dried Chili Using ISOLUTE. Myco Prior to LC-MS/MS Analysis

MS Interpretation I. Identification of the Molecular Ion

LC-MS Based Metabolomics

The Theory of HPLC. Quantitative and Qualitative HPLC

Q-TOF PREMIER DYNAMIC RANGE ENHANCEMENT AND ACCURATE MASS MEASUREMENT PERFORMANCE

Die Nadel im Heuhaufen

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

Biotransformation of benzotriazoles: insights from transformation product identification and compoundspecific

Report AFK0242/18 TABLE OF CONTENTS

Agilent 6400 Series Triple Quadrupole Users Workshop. MH QQQ Users workshop 2/21/2014 1

Accelerated Impurity Profiling Workflow for Bulk Drugs and Formulations using an Accurate Mass Workhorse

LC/MS/MS qua ntitation of β-estradiol 17-acetate using an Agilent 6460 Triple Quadrupole LC/MS working in ESI negative ion mode

Analysis of Illegal Dyes in Food Matrices using Automated Online Sample Preparation with LC/MS

This document is a preview generated by EVS

An Effective Workflow for Impurity Analysis Incorporating High Quality HRAM LCMS & MSMS with Intelligent Automated Data Mining

Accurate Mass Analysis of Hydraulic Fracturing Waters: Identification of Polyethylene Glycol Surfactants by LC/Q-TOF-MS

Agilent All Ions MS/MS

Overview. Introduction

Accurate Mass Analysis of Hydraulic Fracturing Waters

Certified Reference Material - Certificate of Analysis Methylone, Primary Standard

Clinical Toxicology. Biomass Component Extraction: The uneaten cooked plant specimen was prepared for

Bioanalytical Chem: 4590: LC-MSMS of analgesics LC-MS Experiment Liquid Chromatography Mass Spectrometry (LC/MS)

Lirui Qiao, 1 Rob Lewis, 2 Alex Hooper, 2 James Morphet, 2 Xiaojie Tan, 1 Kate Yu 3

Analysis of a Verapamil Microsomal Incubation using Metabolite ID and Mass Frontier TM

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer

Simultaneous, Fast Analysis of Melamine and Analogues in Pharmaceutical Components Using Q Exactive - Benchtop Orbitrap LC-MS/MS

Analytical Technologies and Compound Identification. Daniel L. Norwood, MSPH, PhD SCĪO Analytical Consulting, LLC.

Using TOF for Screening and Quantitation of Sudan Red Colorants in Food Application

HPLC Praktikum Skript

Improved 6- Plex TMT Quantification Throughput Using a Linear Ion Trap HCD MS 3 Scan Jane M. Liu, 1,2 * Michael J. Sweredoski, 2 Sonja Hess 2 *

Utilizing ELSD and MS as Secondary Detectors for Prep HPLC and Flash Chromatography. Tips and Techniques to Optimize ELSD and MS based Purification

LC-HRMS: Challenges for Routine Implementation

Analyst Software. Automatic Optimization Tutorial

LC/Q-TOF Workflows for Comprehensive Micropollutant Analysis

Improved Automated Sample Preparation for the Analysis of 25-OH-Vitamin D3 by LC/MS/MS

Transcription:

Nontarget Analysis via LC-QTOF-MS to Assess the Release of Organic Substances from Polyurethane Coating Agnessa Luft, Kathrin Bröder, Uwe Kunkel,#, Manoj Schulz, Christian Dietrich, Roland Baier, Peter Heininger and Thomas A. Ternes, * Federal Institute of Hydrology (BfG), Koblenz, Germany # present address: Bavarian Environment Agency, Augsburg, Germany Federal Waterways Engineering and Research Institute, Karlsruhe, Germany * Corresponding author phone: +49 261-1306 5560; fax: +49 261-1306-5363; e-mail: ternes@bafg.de Content Chemicals and Standards... 3 Test Materials... 4 HRMS Analysis via LC-QTOF-MS... 5 Quantification of the Identified Substances verified by Authentic Reference Standards... 6 Data Analysis of Qualitative Screening... 8 Bacterial Screening Toxicity Test... 9 Leaching Experiments DOC, TNb and LC-QTOF-MS Results...10 Identification...19 References...29 Pages: 29 Tables: 7 Figures: 12 Tables Table S1. Seven reference standards used in the study.... 3 Table S2. Organic substances in the used 1C-PU coating according to manufacturer declaration.... 4 Table S3. MS Parameters for measurements in positive and negative ESI mode.... 5 Table S4. Overview of the quantified substances with their mass, limit of quantification (LOQ) and results of the preliminary environmental analysis of three surface waters. Rhine and Mosel samples are composite samples of 3 months (M). Teltowkanal samples are grab samples.... 7 Table S5. Parameter for peak extraction and alignment (MarkerView ).... 9 Table S6. Parameter for gradient separation used a mobile phase consisting of methanol, ethyl acetate and n- hexane.... 9 Table S7. Substances detected in leachates summarized with their retention time, mass, intensity, fragments, and group. The table consists of masses belonging to groups A E, including p-toluenesulfonic acid (1 30), masses without specific group assignment (31 41), masses with insufficient MS 2 spectra (42 47), and mass without MS 2 spectra (48). The masses are sorted by intensity (pos.) within the group. Chemical structures verified by reference standard are highlighted in gray.... 19 Figures Figure S1. Leaching experiment of 1C-PU coating with varying hardening and leaching duration. Sum of peak intensities (I) with and (II) without adducts and isotopes and number of peaks (III) with and (IV) without adducts S1

and isotopes. MQ water was used as leaching water. Analysis was performed in the positive ionization mode using LC-QTOF-MS. The statistical errors of the measurements are given as 95% confidence intervals (n = 3). 10 Figure S2. TNb in samples of leachate from the leaching experiment with varying polymer hardening (t= 0, 24 h and 14 d) and leaching duration. MQ water was used as leaching water.... 11 Figure S3. Peak intensities of masses belonging to groups A E in leachate samples from the leaching experiment with varying polymer hardening (t = 0, 24 h and 14 d). MQ water was used as leaching water. Analyses were performed in the positive ionization mode using LC-QTOF-MS (only No. 11 was measured in negative ionization mode). The statistical errors of the measurements are given as standard deviation (n = 3). Masses obtained by MarkerView. t R is given in min.... 13 Figure S4. (I) Sum of peak intensities, (II) DOC, (III) sum of peak numbers and (IV) TNb in leachate samples from the leaching experiment with varying leaching water, MQ and river water (RW). The polymer hardening duration was 24 h. For (I) and (III), analyses were performed in the positive ionization mode using LC-QTOF- MS.... 14 Figure S5. Peak intensities of masses belonging to groups A E in leachate samples from the leaching experiment with varying leaching water, MQ and river water. The polymer hardening duration was 24 h. Analyses were performed in the positive ionization mode using LC-QTOF-MS. Masses obtained by MarkerView. t R is given in min.... 17 Figure S6. (I) Sum of peak intensities [%] after repetitive water renewals compared to the peak intensities prior to any water renewals. The same comparison using (II) DOC [%], (III) number of peaks [%] and (IV) TNb [%]. Polymer hardening duration was 24 h. Leaching duration before water renewals was 14 d. Leaching duration after each water renewal was 24 h. MQ and river water (RW) were used as leaching water. For (I) and (III), analyses were performed in the positive ionization mode using LC-QTOF-MS.... 18 Figure S7. Final peaks (after subtraction steps) were detected in leachates from leaching experiment I. Peak intensities resulted from hardening duration t = 0 (direct water addition after final material preparation) and leaching duration t = 14 d. Analyses were performed in the positive and negative ionization mode using LC- QTOF-MS. The arrow indicates the one peak that was only visible in negative ionization mode... 19 Figure S8. Examples of one of the numerous possible structural composition of two of the declared prepolymers.... 22 Figure S9. Chemical structures of the first three substances suggested by MetFrag for measured MS 2 spectrum in positive ionization mode.... 23 Figure S10. MS 2 spectra of identified substances of (I) N-(tosyl)carbamate, (II) p-toluenesulfonamide, (III) p- toluenesulfonic acid, (IV) 4,4 -MDI, (V) TDI, and (VI) [C 2 H 4 O] n derivatives. Intensities are on a different scale from PeakView due to data conversion to mzml (open format).... 26 Figure S11. (I) Relative amounts (sum of peak intensities) of the five characterized groups and of the peaks without any structure proposal in total. (II VI) In addition, the relative amount of substances within the groups A E. The sum of peak intensities was formed by summarized the peak intensities over all leaching parameters (leaching duration and hardening). Substances that were identified by reference standard are highlighted in gray. t R is given in min.... 27 Figure S12. Luminescent bacteria inhibition test with Aliivibrio fischeri of leachates from leaching experiments (I) with varying polymer hardening duration, (II) with varying water types and (III) with water renewal. Hardening duration was set to 24 h in (II). (IV) Gradient separation step with leachates from leaching experiments with varying hardening duration and standards. Only MQ was used as leaching water in (I, IV). Dark spots indicate toxicity to Aliivibrio fischeri. The darker the spot, the higher the degree of toxicity. Of all samples, an amount of 10 µl was sprayed on the TLC plate using an automatic TLC sampler. After an exposure time of 10 min the detection was performed with the TLC Visualizer.... 29 S2

Chemicals and Standards Stock solutions of reference standards (Table S1) with concentration of 10 mg L -1 were prepared in methanol. Further dilution steps were done to prepare final reference standard solutions to a concentration of 1 µg L -1, 10 µg L -1 and 1000 µg L -1 for calibration. To compare the reference standards with analytes from leachate samples, ultrapure water (MQ) was also used as solvent to avoid any negative effects on the chromatography. The stock solutions were stored in the freezer at 20 C. The diluted standard solutions were stored in the dark at 4 C. Table S1. Seven reference standards used in the study. CAS Substance Molecular weight Molecular Formula - Ethyl N-(3-amino-2-methylphenyl)carbamate 194.23 C 10 H 14 N 2 O 2 7450-62-6 Ethyl N-[5-(ethoxycarbonylamino)-2-methylphenyl]carbamate 266.29 C 13 H 18 N 2 O 4 5577-13-9 Ethyl N-(tosyl)carbamate 243.28 C 10 H 13 NO 4 S 14437-03-7 Methyl N-(tosyl)carbamate 229.25 C 9 H 11 NO 4 S 70-55-3 p-toluenesulfonamide 171.22 C 7 H 9 NO 2 S 6192-52-5 p-toluenesulfonic acid 172.20 C 7 H 8 SO 3 10097-16-2 Diethyl 4,4'-methylenebis(N-phenylcarbamate) 342.40 C 19 H 22 N 2 O 4 S3

Test Materials Table S2. Organic substances in the used 1C-PU coating according to manufacturer declaration. S4

HRMS Analysis via LC-QTOF-MS MQ water with 0.1% formic acid was used as mobile phase A and acetonitrile with 0.1% formic acid as mobile phase B. The gradient of mobile phase A was as follows: start with 98%, after 3 min decrease to 2% within 15 min, kept isocratic for 6 min, returned to the initial conditions (98%) within 0.5 min which was held for the last 5.5 min. The total run time was 30 min. The flow rate was adjusted to 200 µl min -1 and the column oven temperature to 25 C. The injection volume of the sample was 10 µl. A Luna 3 µm C18 column (150 x 2 mm, 3 µm; Phenomenex, Aschaffenburg, Germany) was used for chromatographic separation. MS was performed in full scan TOF-MS and MS/MS mode (high resolution) with information dependent acquisition (IDA) experiments (product ion). The resolution of measurements was 35,000 at m/z = 400 and the mass accuracy below 5 ppm. Further important MS parameters for measurements in positive and negative ESI mode are presented in Table S3. Table S3. MS Parameters for measurements in positive and negative ESI mode. Parameter positive negative m/z range 100-2000 100-2000 m/z range for IDA 30-1200 30-1200 # of IDA experiments / spectra 8 8 Curtain gas / psi 40 40 Ion source gas 1 / psi 35 35 Ion source gas 2 / psi 45 45 IonSpray voltage floating / V 5500-4500 Temperature / C 550 550 Collision energy for IDA / ev 40-40 Declustering potential / V 60-100 An automated external calibration system (Calibrant Delivery System, CDS) was used for mass calibration of the mass spectrometer to maintain the mass accuracy during the batch S5

measurements. This was performed by using an APCI calibration solution (positive and negative polarity solutions). The TOF was calibrated every 2.5 h during the batch measurement in an air-conditioned room at 24 C ± 1 C. When measuring the samples of the first leaching experiment, the samples were injected in triplicate, for subsequent samples no repeat injections were used. Quantification of the Identified Substances verified by Authentic Reference Standards An external calibration with 17 calibration points (0 1000 µg L -1 ) was used. The limit of quantification (LOQ) was defined as the lowest point in the calibration curve with a signal to noise ratio (S/N) of at least 10. Leachate samples were used for analysis, undiluted as well as diluted (1:10, 1:100). S6

Table S4. Overview of the quantified substances with their mass, limit of quantification (LOQ) and results of the preliminary environmental analysis of three surface waters. Rhine and Mosel samples are composite samples of 3 months (M). Teltowkanal samples are grab samples. No./ Substance Ionization Group a Mode Mass b [M+H] + or [M H] LOQ [ g L -1 ] Rhine, Koblenz 2016 [ g L -1 ] Surface water M1-3 M7-9 Mosel, Koblenz 2016 [ g L -1 ] M1-3 M7-9 Teltowkanal, Berlin [ g L -1 ] 2016/09/09 2016/09/11 M4-6 M10-12 M4-6 M10-12 2016/09/10 2016/09/12 1 A 2 A 10 B Ethyl N-(tosyl)carbamate pos. 244.0638 0.06 Methyl N-(tosyl)carbamate pos. 230.0482 0.06 p-toluenesulfonamide pos. 172.0427 10 < LOQ < LOQ < LOQ < LOQ < LOQ < LOQ < LOQ < LOQ < LOQ < LOQ < LOQ < LOQ < LOQ < LOQ < LOQ < LOQ < LOQ < LOQ < LOQ < LOQ < LOQ < LOQ < LOQ < LOQ < LOQ < LOQ < LOQ < LOQ < LOQ < LOQ < LOQ < LOQ < LOQ < LOQ < LOQ < LOQ 11 p-toluenesulfonic acid neg. 171.0121 0.1 < LOQ < LOQ < LOQ < LOQ 11 0.6 < LOQ < LOQ < LOQ < LOQ 4.8 < LOQ 12 C Diethyl 4,4'-methylenebis(Nphenylcarbamate) pos. 343.1652 0.03 < LOQ < LOQ < LOQ < LOQ < LOQ < LOQ < LOQ < LOQ < LOQ < LOQ < LOQ < LOQ 16 D Ethyl N-[5-(ethoxycarbonylamino)- 2-methyl-phenyl]carbamate pos. 267.1339 0.03 < LOQ < LOQ < LOQ < LOQ < LOQ < LOQ < LOQ < LOQ < LOQ < LOQ < LOQ < LOQ 19 D Ethyl N-(3-amino-2- methylphenyl)carbamate pos. 195.1128 0.1 < LOQ < LOQ < LOQ < LOQ < LOQ < LOQ < LOQ < LOQ < LOQ < LOQ < LOQ < LOQ a SI Table S7, b mass range for extraction of ion chromatograms (EICs) /+ 0.01 S7

Data Analysis of Qualitative Screening MS data acquisition was controlled with Analyst TF 1.5.1 software (SCIEX). Data were analyzed using MarkerView 1.2.1, MultiQuant 2.1 and PeakView 1.2.0.3 software (SCIEX). With the MarkerView software the data of all samples measured in one batch were analyzed and presented in lists as so called features consisting of extracted peaks with their respective mass and retention time. Parameters for peak extraction (see Table S5) were set to obtain these data lists. MultiQuant software was used to perform automatic peak integration and, if necessary, to integrate manually. Thus, the peak data was completed by peak intensity in addition to mass and retention time obtained from MarkerView data. Peaks which were also detected with similar intensity in control samples (the ratio of peak intensity of sample and control sample less than 10) were deleted. This was done to eliminate peaks originating from the test system. The programs R 3.0.3 and Tinn-R Editor 2.4.1.7 in combination with the software R package nontarget 1.5 (Eawag, Dübendorf, Switzerland) were used to detect, filter and determine adduct and isotope relations in the MS data set. The following adducts and isotopes were considered in the positive mode: [M+H] +, [M+Na] +, [M+NH 4 ] +, [M+K] + (adducts) and 13 C, 15 N, 34 S, 37 Cl, 81 Br, 41 K (isotopes). Here, the option was set to allow doubly charged ions. S8

Table S5. Parameter for peak extraction and alignment (MarkerView ). Peak extraction and alignment Data to process Alignment Filtering Period 1 Experiment 1 Min. Retention Time Max. Retention Time Subtraction Offset MarkerView 1 min Subtraction Mult. Factor 1.3 30 min Noise Threshold 100 Min. Spectral Peak Width Min. RT Peak Width Retention Time Tolerance Mass Tolerance Remove peaks < Use Global Exclusion List 10 scans 80 ppm 4 scans 0.3 min 50 ppm 3 a / - b False Max. Number of Peaks 9000 Perform RT correction False Normalization Perform normalization False a remove peaks for measurements with sample injection in triplicate b no remove peaks for measurements with single sample injection Bacterial Screening Toxicity Test Table S6. Parameter for gradient separation used a mobile phase consisting of methanol, ethyl acetate and n-hexane. Step Methanol [Vol %] Ethyl acetate [Vol %] n-hexane [Vol %] Migration distance [mm] Drying time [min] 1 100 0 0 15 3 2 80 20 0 18 3 3 70 30 0 21 2 4 60 40 0 24 2 5 50 50 0 27 2 6 30 70 0 30 2 7 10 90 0 33 2 8 0 100 0 36 2 9 0 60 40 39 2 10 0 20 80 42 2 11 0 0 100 45 2 S9

Leaching Experiments DOC, TNb and LC-QTOF-MS Results LC-QTOF-MS - Subtraction of Adducts and Isotopes. After a blank subtraction step, adducts and isotope ions were additionally subtracted. By doing so, the sum of peak intensities and peak numbers was reduced as shown in the Figure S1. However, the shape of the curves remained the same. (I) (II) (III) (IV) Figure S1. Leaching experiment of 1C-PU coating with varying hardening and leaching duration. Sum of peak intensities (I) with and (II) without adducts and isotopes and number of peaks (III) with and (IV) without adducts and isotopes. MQ water was used as leaching water. Analysis was performed in the positive ionization mode using LC-QTOF-MS. The statistical errors of the measurements are given as 95% confidence intervals (n = 3). S10

I) Leaching Experiment of varying Polymer Hardening and Leaching Duration. Figure S2. TNb in samples of leachate from the leaching experiment with varying polymer hardening (t= 0, 24 h and 14 d) and leaching duration. MQ water was used as leaching water. 1 A 2 A 3 A 4 A 5 A 6 A S11

7 B 8 B 9 B 10 B 11 12 C 13 C 14 C 15 D 16 D 17 D 18 D S12

19 D 20 D 21 D 22 D 23 D 24 D 25 E 26 E 27 E 28 E 29 E 30 E Figure S3. Peak intensities of masses belonging to groups A E in leachate samples from the leaching experiment with varying polymer hardening (t = 0, 24 h and 14 d). MQ water was used as leaching water. Analyses were performed in the positive ionization mode using LC-QTOF-MS (only No. 11 was measured in negative ionization mode). The statistical errors of the measurements are given as standard deviation (n = 3). Masses obtained by MarkerView. t R is given in min. S13

II) Leaching Experiment with varying Leaching Water. The measured DOC showed no difference between MQ water and river water. A maximum DOC level of 1.1 g C L -1 was measured in contact with MQ water and river water at a leaching duration of 14 d (Figure S4- II). The measured TNb was different in MQ water and river water at a leaching duration of 14 d, whereby a maximum TNb level of 18.2 mg L -1 in river water and 13.9 mg L -1 in MQ water was measured (Figure S4-IV). At 6 h of leaching duration the sum of peak intensities was comparable in MQ water and river water, while between 24 h and 14 d the sum of peak intensities increased in river water with the leaching duration more than in MQ water (Figure S4-I). The number of peaks remained relatively constant at all leaching durations and was similar in MQ water and river water (Figure S4-III). (I) (II) (III) (IV) Figure S4. (I) Sum of peak intensities, (II) DOC, (III) sum of peak numbers and (IV) TNb in leachate samples from the leaching experiment with varying leaching water, MQ and river water (RW). The polymer hardening duration was 24 h. For (I) and (III), analyses were performed in the positive ionization mode using LC-QTOF-MS. S14

Group A Group B Group C S15

Group D S16

Group E Figure S5. Peak intensities of masses belonging to groups A E in leachate samples from the leaching experiment with varying leaching water, MQ and river water. The polymer hardening duration was 24 h. Analyses were performed in the positive ionization mode using LC-QTOF-MS. Masses obtained by MarkerView. t R is given in min. III) Leaching Experiment with Water Renewal. In MQ water, after the first water renewal, the leached DOC was only 6% of what was released during the first 14 d. This was similar in river water. After the third water renewal, the released DOC was less than 2% of the DOC released after 14 d. As with the initial 14 d leaching period (Figure S4-II), after each water renewal, the DOC in MQ water was relatively comparable with the DOC in river water (Figure S6-II). However, with respect to TNb a difference was observed between the two water types (Figure S6-IV) as was observed after the initial 14 d leaching period (Figure S4- IV). After the first water renewal, the TNb was in MQ water 15% of the value before any water renewal and in river water was 5%. A similar difference was also observed after the subsequent two water renewals (Figure S6). S17

The LC-QTOF-MS results showed, as with the DOC results, that further compounds were leached out of the test material (Figure S6-I and S6-III). In MQ water, after the first water renewal, the sum of peak intensities (Figure S6-I) was still 53% of what was released during the first 14 d. Even after the third water renewal, the sum of peak intensities was 37% of the sum prior to any water renewals. Although the trends in DOC and sum of peak intensities corresponded well to one another, the two values measure different properties and therefore are not expected to be proportional. This can be seen when comparing Figure S6-I and S6-II. (I) (II) (III) (IV) Figure S6. (I) Sum of peak intensities [%] after repetitive water renewals compared to the peak intensities prior to any water renewals. The same comparison using (II) DOC [%], (III) number of peaks [%] and (IV) TNb [%]. Polymer hardening duration was 24 h. Leaching duration before water renewals was 14 d. Leaching duration after each water renewal was 24 h. MQ and river water (RW) were used as leaching water. For (I) and (III), analyses were performed in the positive ionization mode using LC-QTOF-MS. S18

Identification Substances detected in positive and negative ionization mode are plotted in Figure S7 and listed in Table S7. Some substances could be measured in both positive and negative ionization mode while one additional substance was detected exclusively in negative ionization mode. Figure S7. Final peaks (after subtraction steps) were detected in leachates from leaching experiment I. Peak intensities resulted from hardening duration t = 0 (direct water addition after final material preparation) and leaching duration t = 14 d. Analyses were performed in the positive and negative ionization mode using LC-QTOF- MS. The arrow indicates the one peak that was only visible in negative ionization mode. Table S7. Substances detected in leachates summarized with their retention time, mass, intensity, fragments, and group. The table consists of masses belonging to groups A E, including p-toluenesulfonic acid (1 30), masses without specific group assignment (31 41), masses with insufficient MS 2 spectra (42 47), and mass without MS 2 spectra (48). The masses are sorted by intensity (pos.) within the group. Chemical structures verified by reference standard are highlighted in gray. Proposed chemical Mass No./ t structures/ R Intensity measd. Fragments in Group a Identification (pos/neg) [min] confidence level b (L) [M+H] + sample / c Five most intense fragments from MS 2 spectra (pos/neg) [M-H] - 1 A L1 15.61 244.0659 8.3E+06 198.0238 155.0179 119.0629 91.0567 65.0427 242.0517 9.5E+06 196.0090 170.0293 155.0180 105.9615 42.0027 2 A L1 14.80 230.0500 6.7E+05 198.0243 155.0180 119.0630 91.0566 65.0423 228.0364 1.4E+06 196.0095 170.0320 155.0189 105.9615 42.0024 3 A L3 16.33 256.0668 5.6E+05 173.0292 155.0181 119.0633 91.0568 65.0422 4 A L3 14.03 274.0772 2.3E+05 198.0252 155.0182 119.0615 91.0571 65.0414 272.0631 1.4E+06 196.0093 170.0297 106.0674 73.0314 42.0022 S19

5 A Side-chain structure could not be proposed due to missing characteristic MS 2 fragments. L4 17.16 471.0927 1.4E+05 256.0666 198.0258 155.0180 102.0578 91.0561 6 A L3 17.27 272.0976 8.8E+04 198.0249 155.0173 119.0630 91.0567 65.0408 270.0838 4.1E+05 196.0089 170.0293 155.0176 105.9611 42.0018 7 B 17.35 280.1395/ 298.1506 d 1.8E+06 155.0178 124.1141 109.1034 91.0569 65.0421 8 B 16.58 280.1387/ 298.1503 d 1.5E+06 155.0180 124.1141 109.1034 91.0568 65.0424 9 B L3 16.05 280.1393/ 298.1507 d 2.4E+05 155.0183 124.1123 109.1036 91.0565 65.0438 10 B L1 13.16 172.0437 1.0E+05 155.0177 119.0646 106.0657 91.0567 65.0424 170.0296 7.3E+05 106.0673 78.9752 61.9730 11 L1 15.85 171.0135 e 3.3E+06 107.0516 79.9588 12 C L1 17.74 343.1686 2.4E+06 297.1269 251.0842 150.0567 132.0460 104.0516 13 C L2 14.99 225.1038 f 1.8E+05 180.0829 132.0466 106.0674 104.0519 77.0413 14 C L2 14.57 402.2070 6.6E+04 384.1950 178.0884 150.0574 132.0464 106.0881 400.1917 5.1E+03 354.1508 295.1101 269.1300 249.0693 223.0895 15 D L3 13.39 429.1794 f 4.5E+05 323.1181 219.0784 193.0993 175.0521 149.0726 427.1649 9.3E+04 321.1038 279.1014 173.0365 147.0572 105.0564 16 D L1 16.04 267.1365 1.4E+05 193.0637 175.0522 147.0571 132.0473 106.0674 17 D L3 12.83 429.1796 f 9.1E+04 323.1185 219.0792 193.0996 175.0523 149.0730 427.1670 2.6E+03 321.1023 279.1011 173.0370 147.0573 105.0567 18 D L2 15.13 267.1371 7.2E+04 193.0626 175.0523 147.0574 132.0455 104.0523 19 D L1 9.63 195.1144 6.0E+04 149.0730 134.0497 121.0779 106.0672 77.0409 20 D L2 10.70 195.1146 3.4E+04 149.0726 121.0775 106.0675 94.0675 77.0412 S20

21 D 13.31 475.2230 1.5E+04 265.1203 221.0941 193.0987 175.0520 149.0725 473.1712 3.7E+03 321.1030 279.1007 173.0365 147.0574 105.0566 22 D L3 14.01 475.2244 1.2E+04 265.1206 221.0948 193.0992 175.0504 149.0726 23 D 9.66 403.2029 6.5E+03 255.1361 193.0996 171.1408 149.0756 106.0673 24 D L3 10.25 403.2022 2.3E+03 255.137 193.1000 171.1398 149.0728 106.0687 25 E L4 12.35 336.1688/ 319.1416 g 1.9E+05 187.0609 143.0350 99.0091 89.0629 45.0375 26 E L4 11.99 275.1150 1.7E+05 143.0354 133.0862 99.0085 89.0610 45.0394 27 E L4 12.59 380.1947/ 363.1682 g 1.7E+05 231.0867 187.0610 143.0357 99.0094 89.0618 28 E L4 11.36 231.0881 1.6E+05 143.0369 133.0873 99.0099 89.0617 45.0379 29 E L4 12.98 336.1688/ 319.1424 g 9.3E+04 275.1129 231.0886 187.0620 143.0354 99.0101 30 E L4 13.06 380.1960/ 363.1693 g 5.6E+04 275.1137 231.0888 187.0621 143.0355 99.0094 31 10.44 180.0825 2.1E+05 152.0638 128.0512 101.0410 77.0412 32 13.13 276.5357 1.5E+05 209.9912 155.0194 119.9446 91.0564 65.0422 33 14.67 133.0668 1.3E+05 115.0564 105.0724 79.0572 77.0415 51.0273 34 11.83 129.0925 1.1E+05 111.0816 91.0569 77.0423 57.0372 43.0233 35 12.42 133.0872 1.1E+05 73.0679 61.0308 45.0394 41.0446 39.0295 36 16.72 263.1092 9.1E+04 226.0801 215.0878 202.0800 133.0309 115.0577 37 13.13 255.0403 7.6E+04 214.0129 168.0382 149.0188 133.0249 121.0249 38 13.02 386.3051 5.9E+04 231.1361 187.1467 170.1192 100.1148 88.0421 39 17.09 247.1127 4.8E+04 228.0970 204.0957 191.0868 178.0793 91.0568 40 10.85 184.1141 4.3E+04 168.0823 156.0826 143.0754 128.0638 115.0563 41 19.49 263.1091 3.8E+04 245.0984 226.0793 215.0887 202.0790 91.0595 42 12.39 101.0612 3.3E+05 43.0237 39.0414 43 9.28 195.1248 2.8E+04 89.0610 45.0379 44 13.45 101.0613 1.3E+04 72.9421 43.0238 41.0524 39.0285 45 14.11 323.2011 7.9E+03 149.0726 46 15.76 271.1463 7.3E+03 108.9642 106.0670 91.0582 79.0584 S21

47 13.14 362.0555 7.1E+04 227.9987 209.9919 191.0170 154.0340 91.0569 48 15.79 101.0614 1.7E+04 a Peaks were assigned to groups as part of the identification process. b According to Schymanski et. al 1 c Sample used for intensity: hardening duration t = 0 (direct water addition) and leaching duration t = 14 d d In-source fragment mass / parent ion ([M+H] + ) mass e This mass was detected only in the negative ionization mode. f In-source fragment mass, parent ion mass unknown g NH 4 + adduct mass / parent ion [M+H] + mass CAS-No. 53317-61-6 CAS-No. 127821-00-5 Figure S8. Examples of one of the numerous possible structural composition of two of the declared prepolymers. S22

1 st O NH S O O OH 2 nd O NH S O O OH 3 rd O NH O S O O Figure S9. Chemical structures of the first three substances suggested by MetFrag for measured MS 2 spectrum in positive ionization mode. S23

(I) (II) S24

(III) (IV) (V) S25

(VI) Figure S10. MS 2 spectra of identified substances of (I) N-(tosyl)carbamate, (II) p-toluenesulfonamide, (III) p- toluenesulfonic acid, (IV) 4,4 -MDI, (V) TDI, and (VI) [C 2 H 4 O] n derivatives. Intensities are on a different scale from PeakView due to data conversion to mzml (open format). S26

(I) (II) (III) (IV) (V) (VI) Figure S11. (I) Relative amounts (sum of peak intensities) of the five characterized groups and of the peaks without any structure proposal in total. (II VI) In addition, the relative amount of substances within the groups A E. The sum of peak intensities was formed by summarized the peak intensities over all leaching parameters (leaching duration and hardening). Substances that were identified by reference standard are highlighted in gray. t R is given in min. S27

(I) (II) (III) (IV) S28

Figure S12. Luminescent bacteria inhibition test with Aliivibrio fischeri of leachates from leaching experiments (I) with varying polymer hardening duration, (II) with varying water types and (III) with water renewal. Hardening duration was set to 24 h in (II). (IV) Gradient separation step with leachates from leaching experiments with varying hardening duration and standards. Only MQ was used as leaching water in (I, IV). Dark spots indicate toxicity to Aliivibrio fischeri. The darker the spot, the higher the degree of toxicity. Of all samples, an amount of 10 µl was sprayed on the TLC plate using an automatic TLC sampler. After an exposure time of 10 min the detection was performed with the TLC Visualizer. References (1) Schymanski, E. L.; Jeon, J.; Gulde, R.; Fenner, K.; Ruff, M.; Singer, H. P.; Hollender, J. Identifying small molecules via high resolution mass spectrometry: communicating confidence Environ. Sci. Technol. 2014, 48 (4) 2097 2098, DOI: 10.1021/es5002105. S29