Sorption isotherms for textile fabrics and foam used in the indoor environment

Similar documents
Moisture properties of self-levelling flooring compounds. Part II. Sorption isotherms.

Resistivity survey at Stora Uppåkra, Sweden

COMPARISON OF THERMAL HAND MODELS AND MEASUREMENT SYSTEMS

Resistivity imaging for mapping of quick clays

Analytical Studies of the Influence of Regional Groundwater Flow by on the Performance of Borehole Heat Exchangers

Design possibilities for impact noise insulation in lightweight floors A parameter study

A beam theory fracture mechanics approach for strength analysis of beams with a hole

Sound absorption properties of a perforated plate and membrane ceiling element Nilsson, Anders C.; Rasmussen, Birgit

A numerical study of vortex-induced vibrations (viv) in an elastic cantilever

Multi (building)physics modeling

Transmuted distributions and extrema of random number of variables

Lattice Boltzmann Modeling From the Macro- to the Microscale - An Approximation to the Porous Media in Fuel Cells -

Aalborg Universitet. Comparison between Different Air Distribution Systems Nielsen, Peter Vilhelm. Publication date: 2006

Reducing Uncertainty of Near-shore wind resource Estimates (RUNE) using wind lidars and mesoscale models

Embankment dam seepage assessment by resistivity monitoring

Aalborg Universitet. Publication date: Document Version Publisher's PDF, also known as Version of record

Optimizing Reliability using BECAS - an Open-Source Cross Section Analysis Tool

Aalborg Universitet. Lecture 14 - Introduction to experimental work Kramer, Morten Mejlhede. Publication date: 2015

The M/G/1 FIFO queue with several customer classes

Published in: Proc. COST Strategic Workshop - Safeguard of the Cultural Heritage, July 11-13, 2011, M. Fioravanti and S. Mecca. Eds.

Tectonic Thinking Beim, Anne; Bech-Danielsen, Claus; Bundgaard, Charlotte; Madsen, Ulrik Stylsvig

A Note on Powers in Finite Fields

Modelling Salmonella transfer during grinding of meat

Characterization of microporous silica-based membranes by calorimetric analysis Boffa, Vittorio; Yue, Yuanzheng

De Prisco, Renato; Comunian, Michele; Grespan, Franscesco; Piscent, Andrea; Karlsson, Anders

The dipole moment of a wall-charged void in a bulk dielectric

Benchmark of Femlab, Fluent and Ansys

Geoelectrical and IP Imaging Used for Pre-investigation at a Tunnel Project. Danielsen, Berit Ensted; Arver, Henrik; Karlsson, T; Dahlin, Torleif

The IEA Annex 20 Two-Dimensional Benchmark Test for CFD Predictions

Lidar calibration What s the problem?

Aalborg Universitet. Land-use modelling by cellular automata Hansen, Henning Sten. Published in: NORDGI : Nordic Geographic Information

Characterization of the Airflow from a Bottom Hung Window under Natural Ventilation

ISO INTERNATIONAL STANDARD

Numerical modeling of the conduction and radiation heating in precision glass moulding

Geophysical techniques for investigating shallow and deep landslides: results in the framework of PREVIEW project (FP6 UE)

Multiple Scenario Inversion of Reflection Seismic Prestack Data

Application of mesoscale models with wind farm parametrisations in EERA-DTOC

The Wien Bridge Oscillator Family

Global Wind Atlas validation and uncertainty

Generating the optimal magnetic field for magnetic refrigeration

This document is a preview generated by EVS

An Equivalent Source Method for Modelling the Lithospheric Magnetic Field Using Satellite and Airborne Magnetic Data

Graphs with given diameter maximizing the spectral radius van Dam, Edwin

Accelerating interior point methods with GPUs for smart grid systems

Matrix representation of a Neural Network

Determination of packaging induced 3D stress utilizing a piezocoefficient mapping device

Kommerciel arbejde med WAsP

Citation for published version (APA): Burcharth, H. F. (1988). Stress Analysis. Aalborg: Department of Civil Engineering, Aalborg University.

Dynamic Effects of Diabatization in Distillation Columns

Organ doses determined using a RANDO phantom for different radionuclide depositions and photon energies

Radioactivity in the Risø District July-December 2013

Radioactivity in the Risø District January-June 2014

Reflection and absorption coefficients for use in room acoustic simulations

Realtime 3D stress measurement in curing epoxy packaging

A systematic methodology for controller tuning in wastewater treatment plants

Berøringsløs optisk måling af gassammensætning ved UV og IR spektroskopi

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress Heiselberg, Per Kvols. Publication date: 2016

Parametric Study on the Dynamic Heat Storage Capacity of Building Elements Artmann, Nikolai; Manz, H.; Heiselberg, Per Kvols

A note on non-periodic tilings of the plane

Optimal acid digestion for multi-element analysis of different waste matrices

ISO INTERNATIONAL STANDARD. Textiles Quantitative chemical analysis Part 1: General principles of testing

A comparison study of the two-bladed partial pitch turbine during normal operation and an extreme gust conditions

Aalborg Universitet. Published in: Proceedings of Roomvent Publication date: 2007

On the physical limit of radar absorbers

Diffusion of sulfuric acid in protective organic coatings

Prediction of airfoil performance at high Reynolds numbers.

Convergence analysis for a class of LDPC convolutional codes on the erasure channel

Conceptual design of a thorium supplied thermal molten salt wasteburner

Application of joint inversion and fuzzy c-means cluster analysis for road preinvestigations

Design of Robust AMB Controllers for Rotors Subjected to Varying and Uncertain Seal Forces

Adsorption boundary curve influenced by step interval of relative humidity investigated by Dynamic Vapour Sorption equipment

Tilburg University. Strongly Regular Graphs with Maximal Energy Haemers, W. H. Publication date: Link to publication

HIF-1 can act as a tumor suppressor gene in murine Acute Myeloid Leukemia.

Estimation of Peak Wave Stresses in Slender Complex Concrete Armor Units

Aalborg Universitet. Specification of a Two-Dimensional Test Case Nielsen, Peter Vilhelm. Publication date: 1990

Polydiagnostic study on a surfatron plasma at atmospheric pressure

A Procedure for Classification of Cup-Anemometers

Alkali Release from Typical Danish Aggregates to Potential ASR Reactive Concrete

Impact of the interfaces for wind and wave modeling - interpretation using COAWST, SAR and point measurements

Reflection of sound from finite-size plane and curved surfaces

Comparisons of winds from satellite SAR, WRF and SCADA to characterize coastal gradients and wind farm wake effects at Anholt wind farm

Thermodynamics of monomer partitioning in polymer latices: effect of molar volume of the monomers

Effects of natural solar radiation on manikin heat exchange

GIS Readiness Survey 2014 Schrøder, Anne Lise; Hvingel, Line Træholt; Hansen, Henning Sten; Skovdal, Jesper Høi

Validation of Boundary Layer Winds from WRF Mesoscale Forecasts over Denmark

A Blue Lagoon Function

Development of a Dainish infrastructure for spatial information (DAISI) Brande-Lavridsen, Hanne; Jensen, Bent Hulegaard

Simulating wind energy resources with mesoscale models: Intercomparison of stateof-the-art

Benchmarking of optimization methods for topology optimization problems


Phase Equilibrium in Amino Acid Salt Systems for CO2 Capture

On the Einstein-Stern model of rotational heat capacities

An open sorption heat storage concept and materials for building heat supply

Geometry explains the large difference in the elastic properties of fcc and hcp crystals of hard spheres Sushko, N.; van der Schoot, P.P.A.M.

Document Version Publisher s PDF, also known as Version of Record (includes final page, issue and volume numbers)

Minimum analysis time in capillary gas chromatography. Vacuum- versus atmospheric-outlet column operation Leclercq, P.A.; Cramers, C.A.M.G.

On a set of diophantine equations

Document Version Publisher s PDF, also known as Version of Record (includes final page, issue and volume numbers)

Aalborg Universitet. All P3-equipackable graphs Randerath, Bert; Vestergaard, Preben Dahl. Publication date: 2008

Solar radiation and thermal performance of solar collectors for Denmark

Transcription:

Sorption isotherms for textile fabrics and foam used in the indoor environment Svennberg, Kaisa 2005 Link to publication Citation for published version (APA): Svennberg, K. (2005). Sorption isotherms for textile fabrics and foam used in the indoor environment. Building Physics, LTH, Lund University. General rights Copyright and moral rights for the publications made accessible in the public portal are retained by the authors and/or other copyright owners and it is a condition of accessing publications that users recognise and abide by the legal requirements associated with these rights. Users may download and print one copy of any publication from the public portal for the purpose of private study or research. You may not further distribute the material or use it for any profit-making activity or commercial gain You may freely distribute the URL identifying the publication in the public portal Take down policy If you believe that this document breaches copyright please contact us providing details, and we will remove access to the work immediately and investigate your claim. L UNDUNI VERS I TY PO Box117 22100L und +46462220000 Download date: 12. Dec. 2018

Sorption isotherms for textile fabrics and foam used in the indoor environment Kaisa Svennberg Report TVBH-7227 Lund 2005 Department of Building Physics, LTH

Sorption isotherms for textile fabrics and foam used in the indoor environment Kaisa Svennberg ISRN LUTVDG/TVBH--05/7227--SE(3)

Sorption isotherms for textile fabrics and foam used in the indoor environment Kaisa Svennberg Building Physics, Lund Institute of Technology, and the Moisture Research Centre at Lund University 1 INTRODUCTION Today there is an increasing interest in moisture buffering in the indoor environment including the traditional building materials as well as furniture and furnishing. With new building physical calculation tools developing there is a need for material properties for the materials used in the indoor environment. Moisture material properties for textile materials suitable for building physical calculations are scarce (Harderup 1999; Svennberg 2003). The moisture properties of a textile fabric are determined by the fiber type, the spin and twist of the yarn, the weaving technique and the fabric weight. The fiber will to a great extent govern the equilibrium moisture content together with the yarn properties. The transport properties will be governed by the yarn and weave characteristics. In this paper the sorption isotherms for cold cured polyether foam and five textile fabrics, all typical for the indoor environment are presented. 3 MATERIALS In this study the sorption isotherm for polyether foam and 6 textile fabrics was determined. The foam was a 31 mm thick cold cured polyether foam used as padding in a chair seat. The textile fabric were two textiles for home furnishings (cotton calico and warp union linen), and three furniture fabrics ranging from 50% viscose 50% wool to 100% wool. Table 1 gives the thickness the density and the material composition of the materials. Table 1. Thickness and density Material Thickness (mm) Polyether foam 31 36 100% Cotton 0.4 563 50% Cotton - 50% Flax 0.5 605 50% viscose - 50% wool 1.2 346 15% polyamide - 85% wool 1.0 313 100% wool (felt) 2.5 176 Density (kg/m 3 ) 2 TEXTILE FIBERS Textile fibers are divided in two main groups - natural and man-made depending on their origin. Each of these groups can be dived into two sub groups due to the raw-material of the fiber. The natural fibers are divided into cellulose and protein fibers, and the man-made fibers into regenerate and synthetic fibers (Reis 2003). Cotton, flax, ramie, sisal and jute are cellulose fibers, wool and silk are protein fibers. Viscose, acetate, lyocell and modal are all regenerated fibers of cellulose origin giving them properties similar to the natural cellulose fibers. The synthetic fibers are a large group including common fibers as polyester, polyamide, acrylic and polypropylene as well as more specialized fibers as aramides with extreme tensile strength or very good flame retarding properties. 4 METHODS A sorption balance (DVS 1000, Surface measurements Systems, London, UK) was used to determine sorption isotherms. Sorption isotherms for various materials such as inorganic building materials (Janz and Johannesson 2001; Anderberg 2004; Anderberg 2204), soil materials and food stuff (Arlabosse, Rodier et al. 2003; Wadsö, Svennberg et al. 2004) have been done on the same type of instrument. The sorption balance is a highly sensitive balance placed in a climate chamber with good climatic control. The RH is generated trough a flow of dry nitrogen gas that is divided into two gas streams of which one is saturated with water vapor and the other left dry. By mixing different proportions of the gases, RH between 0 and 98% can be generated. The trueness of RH is 1.0%. The sample is weighed on the instrument balance continuously. The resolution of the balance is 0.1 µg. From each of the five fabrics a sample 20 mm in diameter was used. The polyether foam was cut into

a sample cube each side being approximately 10 mm. The samples were exposed to step changes from 0% - 95% - 0% RH and the equilibrium moisture content was determined for each step. 5 RESULTS Figure 1-3 shows the sorption isotherms for the polyether foam (Fig.1), the home furnishing textiles (Fig.2) and the furniture fabrics (Fig.3). Note the scale on the y-axis in figure 1 is only 1/10 of the one used in figure 2 and 3. Figure 3. The sorption isotherms for (o) 50% viscose 50% wool (plainweave, density 297 kg/m 3 ), (*) 15% polyamide 85% wool (twisted together, jacquard weave, density 313 kg/m 3 ) and (+) 100% wool (felt, density 176 kg/m 3 ). 6 DISCUSSION Figure 1. The sorption isotherm for cold cured polyether foam (density 36 kg/m 3 ). Note the scale on the y-axis. Figure 2. The sorption isotherms for (o) 100% cotton fabric (plainweave, density 563 kg/m 3 ) and (*) 50% cotton 50% flax (plainweave, warp linen union, density 605 kg/m 3 ). The polyether foam has a low moisture uptake and shows no hysteresis. The two textiles for home furnishing show very similar sorption isotherms. The pure cotton fabric shows a larger hysteresis. The highest equilibrium moisture content at high RH was found for the 50% viscose- 50% wool fabric, followed by the pure wool fabric and the wool fabric mixed with 15% polyamide. In the lower RH regions the viscose-wool mix and the pure wool look very similar. The polyamide-wool mix had a slightly lower moisture uptake for the lower RH compared with the other two furniture fabrics. The three wool mixes show the expected differences since viscose fibers have a larger moisture capacity than the wool fibers (Reis 2003). On the other hand the polyamide fibers have a lower moisture capacity. The mix of wool and man-made fibers seem not to affect the hysteresis. The home furnishing fabrics have, as expected, a lower moisture uptake than the wool-mix fabrics (Reis 2003). I plan to continue this study to determine sorption isotherms for textile materials. A special interest will be paid to bed materials both mattresses and bedding fabrics. I will also extend the study to include the determination of moisture transport properties for textile materials.

ACKNOWLEDGEMENTS The support from IKEA and Kinnarp AB is gratefully acknowledged. I thank Lars Wadsö and Anders Anderberg at Building Materials, LTH for valuable experimental help. The work was carried out with financial support from FORMAS and SBUF. REFERENCES Anderberg, A. (2004). Moisture properties of selflevelling flooring compounds. Building Materials. Lund, Lund Institute of Technology, Lund University. Anderberg, A. (2204). Moisture properties of selflevelling flooring compounds. Building Materials. Lund, Lund Institute of Technology, Lund University. Arlabosse, Rodier, et al. (2003). "Comparison between static and dynamic methods for sorption isotherm measurements." Drying Technology 21(3): 479-497. Harderup, L.-E. (1999). Hygroscopic moisture of the indoor air considering non-stationary phenomena. Synthesis of publications for the period 1979-1998. Lund, Sweden, Department of Building Physics, Lund University. Janz, M. and B. F. Johannesson (2001). "Measurement of the moisture storage capacity using sorption balance and pressure extractors." Journal of Thermal Envelope and Building Science 24(4): 316-334. Reis, B. (2003). Textil materiallära-allmän del. Borås, Proteko. Svennberg, K. (2003). Determination of Moisture properties for Materials Exposed to the Indoor Air. Lund, Department of Building Physics, Lund University. Wadsö, L., K. Svennberg, et al. (2004). "An experimentally simple method for measuring sorption isotherms." Drying Technology in press.