Research Article Emittance Measurement for Beamline Extension at the PET Cyclotron

Similar documents
Measurement of transverse Emittance

Preliminary Simulation of Beam Extraction for the 28 GHz ECR Ion Source

DEVELOPMENT OF LARGE SCALE OPTIMIZATION TOOLS FOR BEAM TRACKING CODES*

Beam Diagnostics and Instrumentation JUAS, Archamps Peter Forck Gesellschaft für Schwerionenforschnung (GSI)

STUDY OF THE TRANSVERSE BEAM EMITTANCE OF THE BERN MEDICAL CYCLOTRON

Research Article Calculations for a BWR Lattice with Adjacent Gadolinium Pins Using the Monte Carlo Cell Code Serpent v.1.1.7

Heuijin Lim, Manwoo Lee, Jungyu Yi, Sang Koo Kang, Me Young Kim, Dong Hyeok Jeong

DIAGNOSTIC TEST-BEAM-LINE FOR THE MESA INJECTOR

Longitudinal Measurements at the SLAC Gun Test Facility*

The scanning microbeam PIXE analysis facility at NIRS

Beam Optics for a Scanned Proton Beam at Loma Linda University Medical Center

HITRAP Low Energy Diagnostics and Emittance Measurement

A Measurement of Monoenergetic Neutrons from 9 Be(p,n) 9 B

Development of Large Scale Optimization Tools for Beam Tracking Codes

Imaging principle and experiment results of an 11 MeV low-energy proton radiography system

σ ε ω 1 /σ ω ε α=ω 2 /ω 1

Refurbishment of the Electrostatic Accelerators of ithemba LABS

Diagnostics Requirements for the ARIEL Low Energy Beam Transport

HIGH CURRENT PROTON BEAM INVESTIGATIONS AT THE SILHI-LEBT AT CEA/SACLAY

SRF GUN CHARACTERIZATION - PHASE SPACE AND DARK CURRENT MEASUREMENTS AT ELBE*

Beam Diagnostics Lecture 3. Measuring Complex Accelerator Parameters Uli Raich CERN AB-BI

THE SUPER-FRS PROJECT AT GSI

arxiv: v3 [physics.acc-ph] 21 Mar 2018

Travels with a Cyclotron. David Parker University of Birmingham

Delta undulator magnet: concept and project status

Research Article Attracting Periodic Cycles for an Optimal Fourth-Order Nonlinear Solver

Research related to Geant4 in Korea Heavy-Ion Medical Accelerator

PARTICLE BEAMS, TOOLS FOR MODERN SCIENCE AND MEDICINE Hans-H. Braun, CERN

Development of Soft X-rayX using Laser Compton Scattering

Phase Space Tomography of an Electron Beam in a Superconducting RF Linac

A pepper pot emittance device for 8 kev/u light ion beams Marion RIPERT

Status of Proof-of-Principle Experiment of Coherent Electron Cooling at BNL

LCLS Injector Prototyping at the GTF

arxiv: v2 [physics.acc-ph] 21 Jun 2017

Experimental study of nonlinear laser-beam Thomson scattering

GTF Transverse and Longitudinal Emittance Data Analysis Technique * J.F. Schmerge, J.E. Clendenin, D.H. Dowell and S.M. Gierman

IAP NAN of Ukraine activity in. Possible areas of cooperation in. Roman Kholodov, PICS Meeting, Basivka, Ukraine,

Journal of Radiation Protection and Research

Cornell Injector Performance

Secondary Neutron Dose Measurement for Proton Line Scanning Therapy

Tools of Particle Physics I Accelerators

HIRFL STATUS AND HIRFL-CSR PROJECT IN LANZHOU

Lawrence Berkeley National Laboratory Lawrence Berkeley National Laboratory

The High-Power-Target System of a Muon Collider or Neutrino Factory

Characterization of an 800 nm SASE FEL at Saturation

Research Article In-Pile 4 He Source for UCN Production at the ESS

P-Carbon CNI Polarimeter Operation Experience

High Energy Gain Helical Inverse Free Electron Laser Accelerator at Brookhaven National Laboratory

Research Article A PLS-Based Weighted Artificial Neural Network Approach for Alpha Radioactivity Prediction inside Contaminated Pipes

Emittance and energy spread measurements of relativistic electrons from laser-driven accelerator

Linac Beam Dynamics Code Benchmarking

Research Article The Microphone Feedback Analogy for Chatter in Machining

Fission Fragment characterization with FALSTAFF at NFS

Radiation Shielding of Extraction Absorbers for a Fermilab Photoinjector

LOLA: Past, present and future operation

SIMULATION STUDY FOR THE SEPARATION OF RARE ISOTOPES AT THE SEOUL NATIONAL UNIVERSITY AMS FACILITY

Transverse emittance measurements on an S-band photocathode rf electron gun * Abstract

Beam diagnostics: Alignment of the beam to prevent for activation. Accelerator physics: using these sensitive particle detectors.

DESIGN STUDY OF LCLS CHIRP-CONTROL WITH A CORRUGATED STRUCTURE

Time resolved transverse and longitudinal phase space measurements at the high brightness photo injector PITZ

Development status of non-destructive assay of nuclear material by using laser Compton scattered gamma-rays

A PRELIMINARY ALIGNMENT PLAN FOR RIA AT MSU

E (GMp) Precision Measurement of the Proton Elastic Cross Section at High Q 2. Thir Gautam Hampton University

Research Article Study on Effect of Number of Transparent Covers and Refractive Index on Performance of Solar Water Heater

The accelerators at LNS - INFN and diagnostics aspects of the radioactive beams

Design of a Sector Magnet for High Temperature Superconducting Injector Cyclotron

Muon storage for the muon g-2 experiment at Fermilab

The heavy ion irradiation facility at KVI-CART

New Electron Source for Energy Recovery Linacs

The Groningen Cyclotron at Demokritos Athens

Conference Paper Synthesis and Efficient Phase Transfer of CdSe Nanoparticles for Hybrid Solar Cell Applications

Developments of the RCNP cyclotron cascade

Research Article Emissivity Measurement of Semitransparent Textiles

Structural Characterization of Giant Magnetoresistance Multilayers with New Grazing Incidence X-ray Fluorescence

The FFAG Return Loop for the CBETA Energy Recovery Linac

Introduction to Accelerator Physics Part 1

Modeling of an Extraction Lens System

PIP-II Injector Test s Low Energy Beam Transport: Commissioning and Selected Measurements

DUBNA CYCLOTRONS STATUS AND PLANS

Mapping plasma lenses

Introduction Frankfurt Neutron Source at Stern-Gerlach-Zentrum FRANZ Development of new accelerator concepts for intense proton and ion beams. High in

Introduction to Accelerator Physics CHESS & LEPP

GEANT4 Emittance Diagnostics Simulations for the ERL Injector Prototype

Research Article Visible Light Communication System Using Silicon Photocell for Energy Gathering and Data Receiving

FURTHER UNDERSTANDING THE LCLS INJECTOR EMITTANCE*

TRIUMF Document: 10049

CERN EUROPEAN ORGANIZATION FOR NUCLEAR RESEARCH CTF3 DRIVE BEAM INJECTOR OPTIMISATION

The SARAF 40 MeV Proton/Deuteron Accelerator

In-Flight Fragment Separator and ISOL Cyclotron for RISP

MuSIC- RCNP at Osaka University

arxiv: v1 [physics.ins-det] 15 Jan 2013

Juliane Rönsch Hamburg University. Investigations of the longitudinal phase space at a photo injector for the X-FEL

6/12 GeV CEBAF and HPS beam requirements

Beam dynamics studies of H-beam chopping in a LEBT for project X

Linac JUAS lecture summary

New irradiation zones at the CERN-PS

V. 3. Development of an Accelerator Beam Loss Monitor Using an Optical Fiber

Diagnostic Systems for Characterizing Electron Sources at the Photo Injector Test Facility at DESY, Zeuthen site

Progress towards slice emittance measurements at PITZ. Raffael Niemczyk for the PITZ team, Würzburg, March 20 th 2018

Polarization Preservation and Control in a Figure-8 Ring

Transcription:

Science and Technology of Nuclear Installations Volume 2016, Article ID 4697247, 4 pages http://dx.doi.org/10.1155/2016/4697247 Research Article Emittance Measurement for Beamline Extension at the PET Cyclotron Sae-Hoon Park, Sang-Hoon Lee, and Yu-Seok Kim Department of Energy & Environment Engineering, Dongguk University, Gyeongju Campus, Seokjang-dong, Gyeongju-si, Gyeongsangbuk-do 38066, Republic of Korea Correspondence should be addressed to Yu-Seok Kim; unison@dongguk.ac.kr Received 29 November 2015; Accepted 3 March 2016 Academic Editor: Keith E. Holbert Copyright 2016 Sae-Hoon Park et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. Particle-induced X-ray emission is used for determining the elemental composition of materials. This method uses low-energy protons (of several MeV), which can be obtained from high-energy (of tens MeV) accelerators. Instead of manufacturing an accelerator for generating the MeV protons, the use of a PET cyclotron has been suggested for designing the beamline for multipurpose applications, especially for the PIXE experiment, which has a dedicated high-energy (of tens MeV) accelerator. The beam properties of the cyclotron were determined at this experimental facility by using an external beamline before transferring the ion beam to the experimental chamber. We measured the beam profile and calculated the emittance using the pepper-pot method. The beam profile was measured as the beam current using a wire scanner, and the emittance was measured as the beam distribution at the beam dump using a radiochromic film. We analyzed the measurement results and are planning to use the results obtained in the simulations of external beamline and aligned beamline components. We will consider energy degradation after computing the beamline simulation. The experimental study focused on measuring the emittance from the cyclotron, and the results of this study are presented in this paper. 1. Introduction Particle-induced X-ray emission is a nondestructive technique used for determining the elemental composition of materials or samples. This method has been applied in many different fields using low-energy protons (1 5 MeV); protons with this energy can be generated at MeV accelerator facilities [1]. PET cyclotrons (of 13 MeV) have been proposed for providing a beam of protons with energy of several MeV for designing the beamline for multipurpose applications. To extend their applicability, the cyclotrons can be utilized for analytical techniques that use MeV ion beams with energy attenuation. The PIXE beamline consists of one dipole magnet, one quadrupole doublet, and one quadrupole triplet. These magnets are used for focusing the beam to the PIXE chamber with linear dimension of about 1 mm. The beam size should be adjusted from 1 to 10 mm and the beam current of 50 na should be obtained at the PIXE beamline target chamber. The PIXE beamline from the cyclotron is projected to the target point in a target chamber in the experimental room. The emittance of a PET cyclotron has not been measured at thelatterpartofcyclotrontarget.thebeamprofilehasalready been measured and the beam size and the divergence were shown to be linearly related [2]. However, to extract the external beamline, we measured the beam profile and the emittance by using a diagnostic device employing a more precise measurement method. For the external beamline, the beam profile and the emittance were measured and calculated, and the results will be simulated and aligned with the beamline components. To measure properties of the cyclotron beam, we have to consider the external beamline for the PIXE experiment. This experimental paper focused on measuring the emittance of protons from the PET cyclotron. The experiment was performed at the CRC (Cyclotron Research Center) installed in Chosun University, South Korea. Measuring the beam emittance at a PET cyclotron beamline is of fundamental importance. The traditional method

2 Science and Technology of Nuclear Installations Beam profile in X-axis 3.5 Beam profile in Y-axis 5 3.0 Beam current (na) 4 3 2 Beam current (na) 2.5 2.0 1.5 1.0 1 0.5 0 5 0 5 10 15 20 25 30 35 Position (mm) 0.0 5 0 5 10 15 20 25 30 35 Position (mm) X-axis (a) Y-axis (b) Figure 1: Beam profile at the cyclotron target part. (a) x-axis view and (b) y-axis view. Incident beam x Slit or pepper-pot plate L X Beam profile Figure 2: Experimental setup for emittance measurement. L is the distance between the pepper-pot plate and the beam dump with the radiochromic film. for measuring the beam profile as a function of the strength of a focusing element is not applicable, and only the slit and pepper-pot techniques can be used [3]. Two commonly used emittance measurement methods are the method of slits and the pepper-pot method. The former employs a onedimensional emittance measurement device and the latter employs a two-dimensional one [4]. In our experiments, a pepper-pot plate was installed at the cyclotron target. The wire scanner measured the beam current of the beam profile at the cyclotron target. The beam profile at the cyclotron target was measured by using the NI Labview software and equipmentforcontrollingthemotoranddataacquisitionfor thebeamcurrent.theradiochromicfilmatthebeamdump wasalsocalculatedbyusingmatlabforcalculatingtherms emittance. 2. Materials and Methods A beam of particles can be characterized in detail by using its density in the six-dimensional phase space [5]. Beam emittance is one of the beam properties for particle accelerators. Several methods have been developed for measuring the beam emittance, such as the slit [6], pepper-pot [7, 8], and quad scan methods [9]. We used the pepper-pot method for the direct measurement of three-dimensional beam emittance. The beam profile of the initial beam at the target was acquired using the wire scanner [10], and the results are shown in Figure 1. In the case of the pepper-pot method,weanalyzedtheradiochromicfilmbyusingmatlab. The method of slits employs a one-dimensional emittance measurement device, while the pepper-pot method employs a two-dimensional one [11]. The setup for the measurement basedonthepepper-potmethodisshowninfigure2.the experimental setup consisted of a 2 mm thick pepper-pot plate comprised of carbon that was located at the cyclotron target. The thickness of the pepper-pot plate was set to 2 mm considering the stopping depth of 13 MeV protons. The wire scanner was installed behind the pepper-pot plate. The wire scanner allowed measuring the beam profile of the beam that was incident on the scanner. In film measurements, the distance between the pepper-pot plate and the radiochromic film (GAFCHROMIC film, HD-810 for high density) was 209.5 mm. The incident beam arrived from the cyclotron and penetrated through the pepper-pot plate. The pepper-pot plate coordinate was designated as x, while that of the beam profile was designated by X. The beam size at the pepperpot plate was determined considering the dimensions of the slit appearance, the thickness of the pepper-pot plate, and the distance between the pepper-pot plate and the

Science and Technology of Nuclear Installations 3 Phase space in X-axis 1200 0.010 Y-axis (pixel) 1000 800 600 X 0.005 0.000 400 0.005 200 0.010 200 400 600 800 1000 1200 X-axis (pixel) 4 2 0 2 4 X Figure 3: Film contour map, obtained using Matlab. radiochromic film. The beam distribution was fitted using Gaussian functions for all profile peaks. In the film experiment, the measurement was performed by mounting the radiochromic film on the beam dump. The hole diameters in the pepper-pot plate were 1 mm, and the distance between adjacent holes was 2 mm. The pepper-pot plate was 2 mm thick and had 25 holes. Beam irradiation time was 5 seconds and the beam current at the target was 0.13 μa. Longer irradiation times could result in film damage, thereby destroying the image. Film measurement was performed with short irradiation time for reducing the film image error. The film analysis was performed using Matlab. 3. Results and Discussion The film intensity data were encoded as double precision numbers. In turn, these data were converted to the RGB format, with brightness ranging from 0 to 1. The film image resolution was 600 dots per inch (DPI) and the image size was 1392 1392pixels.Thesizeofonepixelwas42.33μm. The contour map was created using the film data in the RGB format and is shown in Figure 3. The film data were divided into rows (x) andcolumns (y). The sum of all values in a certain row represents the emittance along the y axis, and the sum of all values in a certaincolumnrepresentstheemittancealongthex axis. All rows and columns exhibited five peaks that were fitted with Gaussian functions in Matlab. Three parameters the intensity, peak position, and peak sigma were computed from these Gaussian fits of the film data. The emittance was calculated as [12] ε= x 2 x 2 xx 2. (1) The rms emittance was calculated from the Gaussian fits in Matlab, for both x- andy-directions. The rms emittance values were 40.401 π mm mrad for the x-direction and 47.431 π mm mrad for the y-direction. We also computed the beam twiss parameters from the calculated values of rms Y 0.015 0.010 0.005 0.000 0.005 0.010 0.015 6 Film data Twiss parameter for emittance ellipse 4 (a) Phase space in Y-axis 2 Film data Twiss parameter for emittance ellipse (b) 0 2 4 6 Y Figure 4: Phase space ellipse. (a) X-coordinate and (b) Ycoordinate. emittance. These values determine the shape and orientation of the beam ellipse in the phase space [13]. The phase space ellipses are shown in Figure 4. The red dots delimit the maximal area in the phase space [14], while the black dots enclosed in the red dots are the film data. These results will be used to estimate the beamline simulations. 4. Conclusions The CRC has been proposed to be used for producing an external beamline for experimental research. To use the existing facility for producing PET cyclotron protons as an external beamline, the beam energy should be reduced to several MeV. There is no correlation between beam emittance

4 Science and Technology of Nuclear Installations and energy degradation at the end of beamline. To generate an external beamline, experiments were conducted using the specific data of beam emittance at the latter part of cyclotron target by a more precise measurement method. The beam size was measured with the wire scanner. The rms emittance was calculated from the Gaussian fits parameters and phase spaceellipse.thebeamemittancewasmeasuredforproviding conditioning parameters for design and simulations of beamline components of the external beamline for obtaining the desired beam shape. Competing Interests The authors declare that they have no competing interests. Acknowledgments This research was supported by the National Nuclear R&D Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Science, ICT and Future Planning (2015M2B2A6030404). The authors would like to express their deepest gratitude to the CRC of Chosun University for their help in conducting the experiment. intensity radioactive beams, Review of Scientific Instruments, vol. 73, no. 1, p. 56, 2002. [11] R. Hollinger, K. Volk, and H. Klein, Measurement of the beam emittance of the Frankfurt proton source, Review of Scientific Instruments,vol.73,no.2,p.1027,2002. [12] T. P. Wangler, RF Linear Accelerators, JohnWiley&Sons,New York, NY, USA, 2nd edition, 1998. [13] N.Tongnopparat,L.D.Yu,T.Vilaithong,andH.Wiedemann, Ion beam emittance measurement based on transformation matrix theory, the Korean Physical Society, vol. 53, no. 6, pp. 3744 3748, 2008. [14] S. Kondrashev, A. Barcikowski, B. Mustapha, P. N. Ostroumov, and N. Vinogradov, Development of a pepper pot emittance probe and its application for ECR ion beam studies, Nuclear InstrumentsandMethodsinPhysicsResearchSectionA:Accelerators, Spectrometers, Detectors and Associated Equipment,vol. 606, no. 3, pp. 296 304, 2009. References [1] K. Ishii and S. Morita, Theoretical estimation of PIXE detection limits, Nuclear Instruments and Methods in Physics Research SectionB:BeamInteractionswithMaterialsandAtoms,vol.34, no. 2, pp. 209 216, 1988. [2] S.-H. Park and Y.-S. Kim, Characterization of the beam profile for the PIXE/PIGE beam line at the CRC proton cyclotron, the Korean Physical Society, vol.63,no.7,pp.1291 1295, 2013. [3] C. H. Wang, M. Zhang, M. Clausen, and Z. Kakucs, Slits measurement of emittance on TTF, in Proceedings of the 7th International Conference on Accelerator and Large Experimental Physics Control Systems,Trieste,Italy,October1999. [4] M. Zhang, Emittance formula for slits and pepper-pot measurement, Tech. Rep. FERMILAB-TM-1998, Fermi National Accelerator Laboratory, Batavia, Ill, USA, 1998. [5] K.T.McDonaldandD.P.Russell,Methods of Emittance Measurement, Joseph Henry Laboratories, Princeton University, Princeton, NJ, USA, 1988. [6]C.Liu,D.Gassner,M.Minty,andP.Thieberger,Multi-Slit Based Emittance Measurement Study for BNL ERL, Collider- Accelerator Department Brookhaven National Laboratory, Upton, NY, USA, 2012. [7] H. Takeda and J. H. Billen, PARMILA, Los Alamos National Laboratory Report LA-UR-98-4478, Los Alamos National Laboratory, Los Alamos, NM, USA, 2004. [8] S. Y. Lee, Accelerator Physics, World Scientific Publishing Company, New York, NY, USA, 2nd edition, 2004. [9] J. G. Wang, D. X. Wang, and M. Reiser, Beam emittance measurement by the pepper-pot method, Nuclear Instruments and Methods in Physics Research A,vol.307,no.2-3,pp.190 194, 1991. [10] P. N. Ostroumov, P. Billquist, M. Portillo, and W. Q. Shen, Design and test of a beam profile monitoring device for low

Energy International Rotating Machinery Wind Energy The Scientific World Journal Structures Industrial Engineering Petroleum Engineering Solar Energy Submit your manuscripts at Fuels Engineering Power Electronics International High Energy Physics Photoenergy International Journal of Combustion Nuclear Energy Renewable Energy International Science and Technology of Tribology Nuclear Installations Aerospace Engineering