Stathes D. Paganis Nevis Laboratories, Columbia University, Irvington NY, 10533, USA (On behalf of the ZEUS Collaboration)

Similar documents
Measuring very forward (backward) at the LHeC

The HERA ep Interaction Regions Learned Lessons

TEL AVIV UNIVERSITY. Energy dependence of σ tot (γp) measured with the ZEUS detector at HERA

Studies of the diffractive photoproduction of isolated photons at HERA

ERHIC - A PRECISION ELECTRON-PROTON/ION COLLIDER FACILITY AT BROOKHAVEN NATIONAL LABORATORY

arxiv: v1 [hep-ex] 16 Aug 2010

Measuring very forward (backward) at the LHeC

Diffractive production of isolated photons with the ZEUS detector at HERA

HERA II Physics. Both ZEUS & H1 have made major upgrades in order to utilise the increase in HERA luminosity to the full.

PoS(DIS 2010)058. ATLAS Forward Detectors. Andrew Brandt University of Texas, Arlington

HERMES at HERA: Quark-Gluon Spin Structure of the Nucleon

Introduction to polarimetry at HERA

A New Detector for Physics at HERA - III

PERFORMANCE OF THE ATLAS LIQUID ARGON FORWARD CALORIMETER IN BEAM TESTS

A proposed very high energy electron proton collider, VHEeP

Inclusive Deep-Inelastic Scattering at HERA

Measurements of the Proton F L and F 2 Structure Functions at Low x at HERA

Proton Form Factor Puzzle and the CLAS Two-Photon Exchange Experiment

The Detector Design of the Jefferson Lab EIC

arxiv: v1 [physics.acc-ph] 1 Sep 2015

Target single- and double-spin asymmetries in DVCS off a longitudinal polarised hydrogen target at HERMES

Measuring Form Factors and Structure Functions With CLAS

Bose-Einstein correlations in hadron-pairs from lepto-production on nuclei ranging from hydrogen to xenon

DESY Summer Students Program 2008: Exclusive π + Production in Deep Inelastic Scattering

Hadron multiplicities at the HERMES experiment

A Very Forward Proton Spectrometer for H1 1

Studies of the hadronic component of the photon light-cone wave function using exclusive di-pion events at HERA

Study of di-muon production with the ZEUS detector at HERA

HADRONIZATION IN A NUCLEAR ENVIRONMENT. Nationaal Instituut voor Kernfysica en Hoge-Energiefysica, NIKHEF

Results from combined CMS-TOTEM data

Overview of recent HERMES results

Linear Collider Beam Instrumentation Overview

Fermilab FERMILAB-Conf-00/342-E CDF January 2001

PoS(ICHEP2012)049. Study of tau-pair production at HERA. Masaki Ishitsuka Tokyo Institute of Technology

Luminosity measurement and K-short production with first LHCb data. Sophie Redford University of Oxford for the LHCb collaboration

Novel Measurements of Proton Structure at HERA

Measurement of F L at HERA. S. Glazov, DESY, Ringberg 2008

PoS(KAON09)023. Beam Hole Photon Veto For J-PARC K O TO experiment. Yosuke Maeda Kyoto University

MAGNET INSTALLATION AND ALIGNMENT FOR THE FUJI TEST BEAM LINE AT KEKB

Beauty contribution to the proton structure function and charm results

Gamma-Gamma Physics and Transition Form Factors with KLOE/KLOE-2

AIRFLY: Measurement of the Air Fluorescence induced by electrons

PoS(DIFF2006)005. Inclusive diffraction in DIS H1 Results. Paul Laycock

Status of the PRad Experiment (E )

Inclusive Cross Sections at HERA and Determinations of F L

A gas-filled calorimeter for high intensity beam environments

Machine Detector Interface at Electron Colliders. Hongbo Zhu (IHEP, Beijing)

Gluons at high x in Nuclei at EIC

Jets and Diffraction Results from HERA

Status of the LHCb RICH and hadron particle identification

Physics Results on the Tagged Structure Functions at HERA

Measurements of Proton Structure at Low Q 2 at HERA

JLEIC forward detector design and performance

Calorimetry in. in Nuclear and Particle Physics Experiments

The majorityofevents with a leading proton with 0:6 < x L < 0:9. do not have a visible large pseudorapidity gap in the interval

Last Lecture 1) Silicon tracking detectors 2) Reconstructing track momenta

PoS(ICHEP 2010)170. D +, D 0 and Λ + c production in deep inelastic scattering at HERA

Calorimetry in particle physics experiments

Charm with ZEUS HERA-II data

CsI Calorimeter for KOTO experiment

Measurement of D ± diffractive cross sections in photoproduction at HERA

LHCb Calorimetry Impact

Particle Identification of the LHCb detector

The π 0 Lifetime Experiment and Future Plans at JLab

Physics at HERA. Summer Student Lectures August Katja Krüger Kirchhoff Institut für Physik H1 Collaboration

Junior Research Fellow (JRF), University Grants Commission (UGC), India ( ).

Factorisation in diffractive ep interactions. Alice Valkárová Charles University, Prague

hep-ex/ Jun 1995

Observation of Isolated High-E T Photons in Photoproduction at HERA

Future prospects for the measurement of direct photons at the LHC

Luminosity Measurement at ILC

Lecture LHC How to measure cross sections...

Threshold photoproduction of J/y with the GlueX experiment. Lubomir Pentchev Jefferson Lab for the GlueX collaboration

Beauty jet production at HERA with ZEUS

E (GMp) Precision Measurement of the Proton Elastic Cross Section at High Q 2. Thir Gautam Hampton University

EIC Electron Beam Polarimetry Workshop Summary

Colliders and the Machine Detector Interface

Spacal alignment and calibration

Physics potential of ATLAS upgrades at HL-LHC

Charged current DIS with polarised e ± beams at HERA. Alex Tapper

Time-like Compton Scattering with transversely polarized target

Measurement of charm production in deep inelastic scattering at HERA II Grigorescu, G.T.

7 Physics at Hadron Colliders

LHC State of the Art and News

Measurement of the e + e - π 0 γ cross section at SND

PoS(DIS 2013)083. New Results on Diffractive and Exclusive Production from CDF

Machine-Detector Interface for the CEPC

2.24 Simulation Study of K L Beam: K L Rates and Background Ilya Larin Department of Physics Old Dominion University Norfolk, VA 23529, U.S.A.

DVCS with CLAS. Elton S. Smith. Jefferson Lab. Conference on Intersections of Particle and Nuclear Physics New York, Elton S.

First indication of LPM effect in LHCf, an LHC experiment

Limits on the effective quark radius and the contact-interaction mass scales from inclusive ep scattering at HERA. Aleksander Filip Żarnecki

arxiv: v1 [physics.ins-det] 23 Oct 2017

3.2 DIS in the quark parton model (QPM)

Concepts of Event Reconstruction

Preliminary Detector Design for the EIC at JLab

Plans to measure J/ψ photoproduction on the proton with CLAS12

HERA Collider Physics

Measurement of the baryon number transport with LHCb

Particle detection 1

Module of Silicon Photomultipliers as a single photon detector of Cherenkov photons

Transcription:

Frascati Physics Series Vol. nnn (2001), pp. 000-000 IX Int. Conf. on Calorimetry in Part. Phys. - Annecy, Oct. 9-14, 2000 A LUMINOSITY SPECTROMETER FOR THE ZEUS EXPERIMENT AT HERA Stathes D. Paganis Nevis Laboratories, Columbia University, Irvington NY, 10533, USA (On behalf of the ZEUS Collaboration) ABSTRACT The HERA luminosity upgrade is expected to generate two major problems in the current method of luminosity determination which is based on counting brehmsstrahlung photons: damage of the calorimeter monitor due to high primary synchrotron radiation and large multiple event (pile-up) corrections. The luminosity spectrometer presented in this talk, is a novel method that reduces the impact of these problems in the luminosity measurement and is expected to yield a total systematic uncertainty of 1.4%. The spectrometer counts brehmsstrahlung photon conversions in the beam pipe exit window using two small calorimeters (former ZEUS beam pipe calorimeters) symmetrically placed away from the synchrotron radiation plane. The photon conversion rate is measured by counting electron-positron (ep) coincidences in the calorimeters. The ep acceptance is measured using a third calorimeter (6 meter tagger) which tags the brehmsstrahlung electrons. The electron-positron pair is separated by a small dipole magnet.

1 Introduction ZEUS is one of the two colliding beam detectors operating at the HERA electron-proton collider at DESY, Germany. In September 2000, HERA completed an eight year running period which provided measurements of deep inelastic scattering (DIS) physics cross sections over a kinematic regime that spans several orders of magnitude of the DIS parameters, Bjorken x and photon virtuality Q 2 1). For the determination of the cross section σ the accurate knowledge of the luminosity L is required since σ = R/L where R is the corrected measured rate of a particular DIS process. In ZEUS experiment the most accurate luminosity measurement achieved is 1.1%. Currently HERA is undergoing a luminosity upgrade and is scheduled to start the new physics run in August 2001. The goal is to increase the peak luminosity from L 1.5 10 31 cm 2 s 1 before the upgrade, to L 7.5 10 31 cm 2 s 1 after the upgrade. The required accuracy in the luminosity measurement after the upgrade is 1 2%. The current ZEUS luminosity monitoring system has to be modified in order to meet the required accuracy because of two new major problems after the HERA luminosity upgrade: 1. Significant increase in the synchrotron radiation (SR). 2. Increase in the number of overlayed events (pile-up) for the physics process (ep epγ) used to measure luminosity, to 1.3 1.5 per HERA bunch crossing. The luminosity spectrometer presented in these proceedings is a new method of measuring luminosity at ZEUS which solves the problem of SR and pile-up, meeting the requirements in the luminosity accuracy imposed by the ZEUS physics goals. 2 The new ZEUS luminosity monitor ZEUS has been succesfully measuring luminosity using the Bethe-Heitler (B-H) ep epγ brehmsstrahlung process which is known theoretically within 0.5%. The photon is radiated with a very small angle with respect to the e-p axis ( 1mrad) and in the past, the rate of these photons was measured by a calorimeter positioned in the HERA tunnel 107 meters away from the interaction point. After the luminosity upgrade, 300 500 W of SR is expected to hit the photon

calorimeter at peak luminosity. Consequently one has to either shield and upgrade the calorimeter or find some other method of measuring the luminosity. ZEUS decided to do both. The proposed and approved new luminosity system for ZEUS is shown in figure 1. Spectrometer W Sampling ZEUS Calorimeters Aerogel Spec. Dipole Cherenkov 000 e- 111 photon 00 00 e+ 11 p 11 e+ e+ 1cm AlWindow 10% Conversion Filter photon Pb Sampling Calorimeter 5.3m 92m 95m 6m Tagger W Spaghetti Calorimeter 104m 105.5m Figure 1: A schematic of the upgraded luminosity system of ZEUS (side view). A B-H photon produced at the IP converts at the aluminum photon pipe exit window and the e + e coincidence is recorded by two small W sampling calorimeters. The scattered B-H positron is detected by the e tagger, a W scintillating fiber calorimeter positioned 5.3 m away from the IP. Nonconverted photons are detected by the photon Pb sampling calorimeter. In this figure the photon rate is measured by two independent methods. First the upgraded old method; a combination of two filters and two aerogel cerenkov counters is placed in front of the photon calorimeter in order to block the SR and correct for the photon energy loss in the filter. The calorimeter energy resolution depends on the accuracy of the energy loss correction performed. The photon pile-up problem though is not solved and certain corrections have to be performed in order to reduce the systematic error due to pile-up. The second and new method of measuring luminosity is the luminosity spectrometer which solves both the SR and pile-up problems by placing two small existing Tungsten scintillator calorimeters away from the SR plane. The photon rate is

Table 1: BPC characteristics. BPC specification BPC performance Depth 24X 0 Moliere radius 13mm Energy resolution 17%/ E (stochastic term) Energy scale calibration ±0.5% Energy uniformity ±0.5% Linearity 1% Position resolution < 1mm Time resolution < 1ns measured indirectly by counting e + e coincidences of photons converted in the photon pipe exit window (about 10%). The spectrometer has small acceptance in coincidences 3% and no acceptance in low energy photons, so that the probability of a pile-up photon coincidence is small. The major contribution in the total systematic error of this method is due to the error in the knowledge of the acceptance. 3 The Luminosity Spectrometer The luminosity spectrometer consists of two well understood small (12cm 12cm 24X 0 ) Tungsten scintillator calorimeters which provide the energy and position of the incident electron, and of a dipole magnet to separate the e + e pair. The calorimeter (former ZEUS Beam Pipe Calorimeter BPC) characteristics are listed in table 1. The spectrometer acceptance A is given by the formula: A = A geom A conv A z (1) where A geom is the acceptance of the photon beam exit window (it is of order 90%), A conv is the conversion rate (for the specific exit window this is A conv 10%), and A z describes the z = E e /E γ dependent part of the acceptance. The spectrometer A z part of the acceptance as a function of the converted photon energy is shown in figure 2. The e + e coincidence acceptance is relatively uniform in the 18-23 GeV photon energy window. All of these accepted coincidences are coming from symmetric conversions i.e. they have z =0.5 ± 0.2.

Spectro acceptance 9.8m downstream the window, BdL 0.3Tm Figure 2: Spectrometer acceptance as a function of the converted photon energy (conversion factor was omitted for simplicity). In the spectrometer method the acceptance is actually measured using a new small Tungsten scintillating fiber calorimeter, the 6-meter tagger (6mt) placed 5.3 meters away from the IP. The 6mt has 100% acceptance in brehmsstrahlung electrons in an energy window where the spectrometer acceptance is maximized (figure 3). A coincidence between the 6mt and the spectrometer should give a total energy equal to the electron beam energy: E e + E γ =27.5 GeV. The expected coincidence rates are high thus providing an online statistically significant luminosity measurement. The converted B-H photon Gaussian profile on the exit window can be reconstructed within a few seconds. The e + e origin Y coordinate Y hit is approximated as the energy-weighted position of the two electrons as measured in the BPC s:

6-m Tagger Acceptance for Bremsstrahlung Acceptance 1 0.8 0.6 0.4 0.2 0 0 2 4 6 8 10 12 14 e - Energy GeV Acceptance 1 0.8 0.6 0.4 0.2 0 0 2 4 6 8 10 12 14 e + Energy GeV Figure 3: Acceptance of the 6m tagger exit window for brehmsstrahlung electrons (top) and positrons (bottom). The acceptance is > 99% over the ranges 6 9GeV for e and 5 8GeV for e +. Y hit = E+ BPC + + Y BPC E + + E (2) where E +,BPC + and E,BPC the energies and positions of the e + and e as obtained from the BPC s. The resolution obtained is around 5 mm with a 2 mm accuracy in the mean of a gaussian assumed profile. The photon profile will provide to HERA beam monitoring information. A list of the most significant systematic errors of the spectrometer method is given in table 2 2). The counting, thermal γ background and proton-beam background errors are currently expected to be relatively low so they are not taken into account. The theoretical calculation of the cross section error was taken as 0.5%. The total systematic error is calculated by summing all errors in quadrature. The total systematic error is expected to be below 1.4%.

Table 2: Systematic Error in luminosity measurement. Error Type L =7 10 31 cm 2 s 1 Multiple event correction 0.5% egas bgnd subtraction 0.5% Total Acceptance error 1.0% Energy Scale errors 0.5% Cross-section Calculation 0.5% Total systematic error 1.4% 4 Conclusions The luminosity spectrometer method for measuring luminosity in the ZEUS experiment at HERA was presented. ZEUS is measuring luminosity by counting photons produced by the Bethe-Heitler ep epγ process. A 10% of these photons are converted in a thin exit window. The spectrometer measures the converted photon rate by counting e +,e coincidences in two small well understood calorimeters. The calorimeters are away from the SR plane and pile-up is a secondary effect. The spectrometer acceptance is measured using an independent device, the 6m e-tagger. The tagger has almost 100% acceptance in B-H electrons in an energy window where the spectrometer acceptance is maximized. The electron and photon energy sum equals the electron beam energy (27.5 GeV ). Detailed calculations show that the luminosity spectrometer can measure luminosity with an accuracy better than 1.4% 2). References 1. H. Abramowicz, A. Caldwell, Rev. Mod. Phys. 71:1275-1410, (1999). 2. A. Caldwell, S. Paganis, R. Sacchi, F. Sciulli, A Luminosity Spectrometer for ZEUS, Internal ZEUS document, (1999).