Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS

Similar documents
Identification and Characterization of an Isolated Impurity Fraction: Analysis of an Unknown Degradant Found in Quetiapine Fumarate

A Workflow Approach for the Identification and Structural Elucidation of Impurities of Quetiapine Hemifumarate Drug Substance

A Rapid Approach to the Confirmation of Drug Metabolites in Preclinical and Clinical Bioanalysis Studies

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

Traditional Herbal Medicine Structural Elucidation using SYNAPT HDMS

Lirui Qiao, 1 Rob Lewis, 2 Alex Hooper, 2 James Morphet, 2 Xiaojie Tan, 1 Kate Yu 3

Q-TOF PREMIER DYNAMIC RANGE ENHANCEMENT AND ACCURATE MASS MEASUREMENT PERFORMANCE

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity

Rapid, Reliable Metabolite Ratio Evaluation for MIST Assessments in Drug Discovery and Preclinical Studies

A Case of Pesticide Poisoning: The Use of a Broad-Scope Tof Screening Approach in Wildlife Protection

Quantitation of High Resolution MS Data Using UNIFI: Acquiring and Processing Full Scan or Tof-MRM (Targeted HRMS) Datasets for Quantitative Assays

C HA R AC T E RIZ AT IO N O F INK J E T P RINT E R C A RT RIDG E INK S USING A CHEMOMETRIC APPROACH

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW

Analysis of Serum 17-Hydroxyprogesterone, Androstenedione, and Cortisol by UPLC-MS/MS for Clinical Research

Streamlining the Analysis of Oral Contraceptives Using the ACQUITY UPLC H-Class System

[application note] ACQUITY UPLC/SQD ANALYSIS OF POLYMER ADDITIVES. Peter J. Lee, and Alice J. Di Gioia, Waters Corporation, Milford, MA, U.S.A.

OVERVIEW INTRODUCTION. Michael O Leary, Jennifer Gough, Tanya Tollifson Waters Corporation, Milford, MA USA

Electron Transfer Dissociation of N-linked Glycopeptides from a Recombinant mab Using SYNAPT G2-S HDMS

Routine MS Detection for USP Chromatographic Methods

Stephen McDonald and Mark D. Wrona Waters Corporation, Milford, MA, USA INT RO DU C T ION. Batch-from-Structure Analysis WAT E R S SO LU T IONS

FORENSIC TOXICOLOGY SCREENING APPLICATION SOLUTION

Stephen McDonald, Mark D. Wrona, Jeff Goshawk Waters Corporation, Milford, MA, USA INTRODUCTION

[ instrument specifications ]

Multi-stage Mass Spectrometry up to MS 4 on a QTof System

ImprovIng ADmE ScrEEnIng productivity In Drug DIScovEry

Metabolic Phenotyping Using Atmospheric Pressure Gas Chromatography-MS

Jonathan P. Danaceau, Erin E. Chambers, and Kenneth J. Fountain Waters Corporation, Milford, MA USA APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS

Accurate Mass Analysis of Hydraulic Fracturing Waters: Identification of Polyethylene Glycol Surfactants by LC/Q-TOF-MS

Improved Extraction of THC and its Metabolites from Oral Fluid Using Oasis PRiME HLB Solid Phase Extraction (SPE) and a UPLC CORTECS C 18

A Quality by Design (QbD) Based Method Development for the Determination of Impurities in a Peroxide Degraded Sample of Ziprasidone

PosterREPRINT COMPARISON OF PEAK PARKING VERSUS AUTOMATED FRACTION ANALYSIS OF A COMPLEX PROTEIN MIXTURE. Introduction

Performing Peptide Bioanalysis Using High Resolution Mass Spectrometry with Target Enhancement MRM Acquisition

Application Note. David A. Weil Zoltan Timar Michael Zumwalt Edgar Naegele. Abstract

MALDI-HDMS E : A Novel Data Independent Acquisition Method for the Enhanced Analysis of 2D-Gel Tryptic Peptide Digests

Identification of Human Hemoglobin Protein Variants Using Electrospray Ionization-Electron Transfer Dissociation Mass Spectrometry

[ xevo G2 tof ] Your Quantitative and Qualitative Questions Answered. Exactly.

Conformational Characterization of Calmodulin by Hydrogen Deuterium Exchange Mass Spectrometry

Accurate Mass Analysis of Hydraulic Fracturing Waters

Analysis of Organic Light Emitting Diode Materials by UltraPerformance Convergence Chromatography Coupled with Mass Spectrometry (UPC 2 /MS)

APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEY WORDS. Simultaneous high-throughput screening of melamine (MEL) and cyanuric acid (CYA).

Overview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada)

Analysis of Labeled and Non-Labeled Proteomic Data Using Progenesis QI for Proteomics

THE IMPLEMENTATION OF A SCREENING WORKFLOW FOR ION MOBILITY QUADRUOPOLE TIME-OF-FLIGHT MASS SPECTROMETRIC ANALYSIS OF PFOS ISOMERS

UNIFI - Targeted and Untargeted Screening MS Software

MassHunter TOF/QTOF Users Meeting

AB SCIEX SelexION Technology Used to Improve Mass Spectral Library Searching Scores by Removal of Isobaric Interferences

UPLC Intact MASS Analysis Application Kit

DETERMINATION OF PESTICIDES IN FOOD USING UPLC WITH POLARITY SWITCHING TANDEM QUADRUPOLE LC/MS/MS

Online Reaction Monitoring of In-Process Manufacturing Samples by UPLC

TargetScreener. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS

WADA Technical Document TD2003IDCR

Implementation of Methods Translation between Liquid Chromatography Instrumentation

USP Method Transfer and Routine Use Analysis of Irbesartan Tablets from HPLC to UPLC

Optimization of the sample preparation and extraction methodology

Basic Principles for Purification Using Supercritical Fluid Chromatography

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION

TANDEM MASS SPECTROSCOPY

IN QUALITATIVE ANALYSIS,

Key Words Q Exactive, Accela, MetQuest, Mass Frontier, Drug Discovery

Toxicity, Teratogenic and Estrogenic Effects of Bisphenol A and its Alternative. Replacements Bisphenol S, Bisphenol F and Bisphenol AF in Zebrafish.

Bioanalytical Chem: 4590: LC-MSMS of analgesics LC-MS Experiment Liquid Chromatography Mass Spectrometry (LC/MS)

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

Application Note. Edgar Naegele. Abstract

ASAP APPLICATION NOTEBOOK: Atmospheric Solids Analysis Probe FINE AND SPECIALTY CHEMICALS ENERGY SYNTHETIC POLYMERS FOOD TESTING

DEMONSTRATING SUPERIOR LINEARITY: THE ACQUITY UPLC PHOTODIODE ARRAY DETECTOR

An Effective Workflow for Impurity Analysis Incorporating High Quality HRAM LCMS & MSMS with Intelligent Automated Data Mining

The Power of LC MALDI: Identification of Proteins by LC MALDI MS/MS Using the Applied Biosystems 4700 Proteomics Analyzer with TOF/TOF Optics

Sensitive and Repeatable Analysis of Pesticides in QuEChERS Extracts with APGC-MS/MS

All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems

Application Note LCMS-112 A Fully Automated Two-Step Procedure for Quality Control of Synthetic Peptides

Live Webinar : How to be more Successful with your ACQUITY QDa Detector?

New Dynamic MRM Mode Improves Data Quality and Triple Quad Quantification in Complex Analyses

Rapid and Accurate Forensics Analysis using High Resolution All Ions MS/MS

Effects of Aqueous Sample Content and Aqueous Co-Solvent Composition on UPC 2 Separation Performance

Prep 150 LC System: Considerations for Analytical to Preparative Scaling

Multiple Fragmentation Methods for Small Molecule Characterization on a Dual Pressure Linear Ion Trap Orbitrap Hybrid Mass Spectrometer

Choosing the metabolomics platform

Peptide Isolation Using the Prep 150 LC System

Structural Analysis by In-Depth Impurity Search Using MetID Solution and High Accuracy MS/MS

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

Mass Spectrometry. Hyphenated Techniques GC-MS LC-MS and MS-MS

Profiling of Diferulates (Plant Cell Wall Cross- Linkers) Using Ultrahigh-performance Liquid. Chromatography-Tandem Mass Spectrometry

Confirmation of In Vitro Nefazodone Metabolites using the Superior Fragmentation of the QTRAP 5500 LC/MS/MS System

Accelerating the Metabolite Identification Process Using High Resolution Q-TOF Data and Mass-MetaSite Software

Using TOF for Screening and Quantitation of Sudan Red Colorants in Food Application

WADA Technical Document TD2015IDCR

Hints and Tips for APGC Coupled with Xevo TQ-S for Food and Environmental Analysis

Accelerated Impurity Profiling Workflow for Bulk Drugs and Formulations using an Accurate Mass Workhorse

Determination of Pharmaceuticals in Environmental Samples

[ XEVO G2-XS QTOF ] EXTRAORDINARY POSSIBILITIES FOR YOUR EVERYDAY ANALYSIS

Technical Note. Introduction

EGASUS. 4D GCxGC TOFMS. Delivering the Right Results

[application note] INTRODUCTION EXPERIMENTAL. Specimens. Extraction

Impurity Profiling of Pharmaceutical Starting Materials Using Gas Chromatography Coupled with High- Resolution Accurate Mass Spectrometry

[ a ppl ic at ion no t e ]

Analyst Software. Automatic Optimization Tutorial

Agilent All Ions MS/MS

MetWorks Metabolite Identification Software

Quantitative Analysis and Identification of Migrants in Food Packaging Using LC-MS/MS

Accurate Mass Measurement for Intact Proteins using ESI-oa-TOF. Application Note. Donghui Yi and Christine Miller Agilent Technologies

Transcription:

Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS Marian Twohig, Michael D. Jones, Dominic Moore, Peter Lee, and Robert Plumb Waters Corporation, Milford, MA, USA APPLICATION BENEFITS This work demonstrates the use of Xevo G2 Tof and novel MS E technology, and its ability to collect exact mass precursor and fragment ion information from every detectable component in a sample, in the analysis and identification of sildenafil impurities in counterfeit tablet samples. INTRODUCTION The profiling, identification, and quantification of impurities plays a critical role at all stages of the drug development and manufacturing process. The levels of impurities of pharmaceutical products are strictly controlled and regulated in order to ensure the safety of the administered drug product. The structure of the impurities must be identified and their pharmacology understood in order for the overall safety of the drug to be characterized. 1 In addition, pharmaceutical manufacturers monitor potential counterfeit drugs through the use of impurity profiling. During the development process, many different routes of synthesis may be evaluated, each producing its own distinct impurity profile. It is critical that these routes of synthesis are thoroughly evaluated and that the impurities produced are identified. This activity is often performed using a combination of NMR and LC/MS/MS. Although modern nominal mass LC/MS instrumentation, such as a tandem quadrupole or ion trap mass spectrometer, can quickly produce high-sensitivity, fast scanning data, the interpretation of its data can be very time consuming and of limited utility due to low mass spectral resolving power. These techniques often require further confirmatory experiments to identify the structure of the impurities. WATERS PRODUCTS Xevo G2 Tof ACQUITY UPLC System ACQUITY UPLC BEH Column MassLynx Software MassFragment Software KEY WORDS Sildenafil, Impurity Analysis, Mass Defect Filter Modern high-sensitivity exact mass instruments with time-of-flight (Tof) technology capable of fast acquisition rates offer the opportunity to dramatically simplify the process of impurity data capture and analysis. The use of simultaneous low and high collision energy data collection (MS E ) allows the interpretation of precursor and fragment ion data from a single analytical run. As this data is collected with a high degree of mass accuracy, elemental compositions can be obtained for both intact molecular ions and structurally significant fragments. Sildenafil citrate is one of the approved synthetic phosphodiesterase Type-5 (PDE-5) inhibitors used in the treatment of erectile dysfunction (ED) and is widely counterfeited. In this application note, we present the use of the Xevo G2 Tof for the applicability of novel MS E technology in the analysis and identification of sildenafil impurities present in counterfeit tablet samples. 1

EXPERIMENTAL Sildenafil tablets were dissolved in a mixture of methanol/water (1:1), filtered, and transferred to an autosampler vial for analysis. The chromatography was performed on a 2.1 x 100 mm, 1.7-µm ACQUITY UPLC BEH C 18 Column. The column was maintained at 45 C. Reversed phase gradient elution was performed at 600 µl/min, using 10 mm NH 4 OAC in water as the aqueous mobile phase, and acetonitrile as the organic modifier. Positive ion electrospray, with a cone voltage of 30 V and a capillary voltage of 3k V were used. Data was collected over the mass range of 50 to 1000 m/z. The data was acquired in MS E mode with the low energy data acquired using a collision energy of 4 ev. Elevated collision energy data was acquired using a collision energy ramp of 25 to 45 ev. MassLynx 4.1 Software was used to acquire the data. RESULTS The total ion chromatogram (TIC) obtained from the analysis of a counterfeit tablet sample of sildenafil is displayed in Figure 1A. Here we can see that the parent drug elutes with a retention time of 8.49 min and there are at least eleven other peaks that elute between 2.75 and 9.79 min. Any of these peaks could represent drug-related impurities or excipient components from the tablet. 14 2 A 0.54 B 0.60 0.67 2.75 8.49 2.00 4.00 6.00 8.00 10.00 2.75 3.66 3.66 4.31 4.86 4.86 5.52 5.77 5.78 6.19 6.19 6.61 6.61 6.81 7.38 7.38 8.49 7.64 9.68 9.68 9.79 2.00 4.00 6.00 8.00 10.00 10.33 9.79 1: TOF MS ES+ TIC 4.08e5 11.14 11.79 1: TOF MS ES+ TIC 1.04e5 11.65 11.48 11.79 Time Figure 1. A) Total ion chromatogram obtained from the analysis of a counterfeit tablet of sildenafil. B) LC/MS data after filtering with the MDF. 2 Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS

The mass spectra displayed in Figure 2 show the elevated and low collision energy of the sildenafil peak. The low collision energy spectrum includes a peak with a measured mass of 475.2127, allowing an elemental composition of C 22 H 31 N 6 O 4 S with a mass error of -0.1 mda to be assigned. The high collision energy data gave rise to two main fragment ions, m/z = 100.0997 and 283.1191, which had mass errors of -0.3 mda and -0.4 mda, respectively. Figure 2. Mass spectra showing the elevated and low collision energy of the sildenafil peak. The elemental composition and fragment ion structures generated using MassFragment are shown in Figure 2. MassFragment is software that automatically identifies product ion fragments using a series of chemically intelligent algorithms. 2 The accurate mass capability of the Xevo G2 Tof mass spectrometer in conjunction with the software capabilities in MassLynx can be used to simplify data analysis. The fractional part of the exact mass of the parent drug m/z can be used to visualize only the drug related material by applying a mass deficiency filter (MDF) to the data. In this case, the exact mass of the sidenafil ion is 475.2127. A 20 mda range was applied to the mass measurement after the decimal point to limit display. The data displayed in Figure 1B shows UPLC/MS data after filtering with the MDF. Here we can see that there are at least 17 drug-related impurities. The use of MDF has greatly improved the signal-to-noise of the related components, most notably at RTs 5.52 min, 6.81 min and 7.64 min. This is due to the reduction in background noise, which allowed improved peak detection for the low concentration drug-related components. Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS 3

The common fragment ions may also be used as an approach to highlight drug-related peaks. The data shown in Figure 3 shows the use of narrow window extracted ion chromatograms for the fragment ions m/z 283.1195 and 100.1001 using a 5 mda window. From this data, we can see six possible drug-related impurities in each trace. 100 8.79 2: TOF MS ES+ 100.1 0.0050Da 4.55e4 7.18 5.87 0 Time 4.00 5.00 6.00 7.00 8.00 9.00 10.00 11.00 Figure 3. The use of narrow window extracted ion chromatograms for the fragment ions m/z = 283.1195 and m/z = 100.1001 using a 5 mda window. All of this data were available from one simple UPLC/MS experiment taking just 13 minutes. Data was processed using MetaboLynx, an Application Manager within MassLynx Software. MetaboLynx MS E fragmentation analysis was used to interrogate both low and high collision energy data simultaneously. This enables the visual alignment of precursor with collision induced dissociation fragment ions for sildenafil and its impurities. The automated structure elucidation tool, MassFragment, was employed to rationalize and identify fragment ion structures. 4 Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS

The elucidation of the impurity structures is facilitated by the elemental composition, which was obtained for both the fragment ions and parent compound molecular mass after data processing with MetaboLynx. The data in Figure 4 shows the elemental composition of the sildenafil-related impurities found in the sample. CONCLUSIONS The Xevo G2 Tof operating in MS E mode provides an excellent approach for the analysis of impurities in pharmaceutical products. The major benefits include: n Precursor mass and fragment ion data is obtained in one simple acquisition, decreasing the need to re-inject samples for targeted ion MS/MS experiments. n All the data is collected in accurate mass mode, allowing the elemental composition of parent and fragment ions to be derived. n The Mass Defect Filter simplifies the task of detecting drug-related impurities by increasing the selectivity of data extraction and improving the visibility of detection for related components. n The use of MetaboLynx and MassFragment allows rapid turnaround from data analysis to data interpretation and reporting. Figure 4. The elemental composition of the sildenafil related impurities found in the sample. References 1. Ahuja S and Alsante K. Handbook of Isolation and Characterisation of Impurities in Pharmaceutical Compounds. 2003; Elsevier. 2. Jones M.D et al. Identification and Characterization of an Isolated Impurity Fraction: Analysis of an Unknown Degradant Found in Quetiapine Fumarate. Waters Application Note. 2009; 720003079en. Waters, ACQUITY UPLC, UPLC, and Xevo are registered trademarks of Waters Corporation. MassLynx, MassFragment, MetaboLynx, and The Science of What s Possible are trademarks of Waters Corporation. All other trademarks are the property of their respective owners. 2011 Waters Corporation. Printed in the U.S.A. January 2011 720003850en AG-PDF Waters Corporation 34 Maple Street Milford, MA 01757 U.S.A. T: 1 508 478 2000 F: 1 508 872 1990 www.waters.com