Agilent s New 8800 ICP-QQQ. Transforming ICP-MS Technology

Similar documents
Agilent 8900 Triple Quadrupole ICP-MS

Determination of challenging elements in ultrapure semiconductor grade sulfuric acid by Triple Quadrupole ICP-MS

Analysis of Trace Metal Impurities in High Purity Hydrochloric Acid Using ICP-QQQ

Agilent s Solutions for Nanoparticles Analysis ICP-MS, ICP-MS/MS, software. Alain Desprez Agilent Technologies

Lead isotope analysis: Removal of 204 Hg isobaric interference from 204 Pb using ICP-QQQ in MS/MS mode

Ultra trace measurement of potassium and other elements in ultrapure water using the Agilent 8800 ICP-QQQ in cool plasma reaction cell mode

Determination of trace elements in ultrapure semiconductor grade sulfuric acid using the Agilent 8900 ICP-QQQ in MS/MS mode

Applications of ICP-MS for Trace Elemental Analysis in the Hydrocarbon Processing Industry

Application note. Trace level analysis of sulfur, phosphorus, silicon and chlorine in NMP using the Agilent 8800 Triple Quadrupole ICP-MS

Accurate analysis of neptunium 237 in a uranium matrix, using ICP-QQQ with MS/MS

Comparing Collision/Reaction Cell Modes for the Measurement of Interfered Analytes in Complex Matrices using the Agilent 7700 Series ICP-MS

The Agilent 7700x ICP-MS Advantage for Drinking Water Analysis

Direct Analysis of Trace Metal Impurities in High Purity Nitric Acid Using ICP-QQQ

IMPROVING DATA QUALITY WITH ADVANCED INSTRUMENTATION UTILIZING MULTIPLE INTERFERENCE REDUCTION TECHNOLOGIES

Advantages of ICP-QQQ for nuclear waste characterisation

Agilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS)

Agilent ICP-MS. Fundamentals of ICP-MS Analysis and Its Applications for Low Level Elemental Determination in Cannabis

Introducing the Agilent 7000A QQQ-MS for GC Sunil Kulkarni Product Specialist Agilent Technologies

Enhancing the productivity of food sample analysis with the Agilent 7700x ICP-MS

Fergus Keenan Shona McSheehy Julian Wills

Accurate Analysis of Trace Mercury in Cosmetics using the Agilent 8900 ICP-QQQ

The New Agilent 7700 Series ICP-MS

The ultratrace determination of iodine 129 in aqueous samples using the 7700x ICP-MS with oxygen reaction mode

Agilent Technologies at TIAFT 2013

Accurate measurement of elemental impurities in metals and metal alloys using the Thermo Scientific icap TQ ICP-MS

Handling Interferences in the Modern Laboratory with Advanced Triple Quadrupole ICP-MS Technology

Implementing EPA Method 6020 with the Agilent ICP-MS Portfolio

Trace elemental analysis of distilled alcoholic beverages using the Agilent 7700x ICP-MS with octopole collision/ reaction cell

Agilent 8800 ICP-QQQ

Direct Measurement of Metallic Impurities in 20% Ammonium Hydroxide by 7700s/7900 ICP-MS

Trace Analyses in Metal Matrices Using the ELAN DRC II

Agilent 8900 Triple Quadrupole ICP-MS LEAVE INTERFERENCES BEHIND WITH MS/MS

Determination of Impurities in Silica Wafers with the NexION 300S/350S ICP-MS

Simple, reliable analysis of high matrix samples according to US EPA Method 6020A using the Agilent 7700x/7800 ICP-MS

Basic and Application Inductively coupled plasma mass spectrometry (ICPMS)

Simplified workflows for the Thermo Scientific icap TQ ICP-MS

Rapid Analysis of High-Matrix Environmental Samples Using the Agilent 7500cx ICP-MS. Application. Author. Abstract. Introduction.

Thermo Scientific icap TQ ICP-MS: Typical limits of detection

ICP-MS. plasma 17OO. High Resolution Multi-Collector ICP-MS.

Application note. Accurate determination of sulfur in biodiesel using Isotope Dilution-Triple Quadrupole ICP-MS (ID-ICP-QQQ) Petrochemical

High-Speed Environmental Analysis Using the Agilent 7500cx with Integrated Sample Introduction System Discrete Sampling (ISIS DS)

Multi-Element Analysis of Petroleum Crude Oils using an Agilent 7900 ICP-MS

Determination of ultratrace elements in photoresist solvents using the Thermo Scientific icap TQs ICP-MS

Agilent 7700 Series. The Smallest, Most Powerful ICP MS Ever Made

Ultra-fast determination of base metals in geochemical samples using the 5100 SVDV ICP-OES

Agilent ICP-MS Journal September 2009 Issue 39

Simple and Reliable Soil Analysis using the Agilent 7800 ICP-MS with ISIS 3

Defining quality standards for the analysis of solid samples

High Throughput Water Analysis using Agilent 7900 ICP-MS coupled with ESI prepfast

Accurate Determination of TiO 2 Nanoparticles in Complex Matrices using the Agilent 8900 ICP-QQQ

Multi-Element Analysis of Cannabis using the Agilent 7800 ICP-MS

The 30-Minute Guide to ICP-MS

Powerful Scan Modes of QTRAP System Technology

Thermo Scientific icap RQ ICP-MS: Typical limits of detection

Translational Biomarker Core

Introduction to the New Agilent 7900

Agilent 8800 Triple Quadrupole ICP-MS: Understanding oxygen reaction mode in ICP-MS/MS

Quantitative analysis of high purity metals using laser ablation coupled to an Agilent 7900 ICP-MS

All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems

Partial Energy Level Diagrams

MassHunter TOF/QTOF Users Meeting

Determination of Chromium in Gelatin Capsules using an Agilent 7700x ICP-MS

Application. Determination of Trace Metal Impurities in Semiconductor-Grade Hydrofluoric Acid. Authors. Introduction. Abstract.

Today s Agilent Solutions for Determining Heavy Metals in Food using Atomic Spectroscopy

Fundamentals of the ICP-MS Technique and How to Resolve Issues for Pharmaceutical Materials (In 20 Minutes) Tim Shelbourn, Eli Lilly and Company

Robust ICP-MS with ease of use and high productivity for routine laboratories

Thermo Scientific ICP-MS solutions for the semiconductor industry. Maximize wafer yields with ultralow elemental detection in chemicals and materials

Thermo VG PQ EXCELL INDUCTIVELY COUPLED PLASMA MASS SPECTROMETER

Hands on mass spectrometry: ICP-MS analysis of enriched 82 Se samples for the LUCIFER experiment

Semiquantitative Screening of Pharmaceutical Antiviral Drugs using the Agilent 7500ce ICP-MS in Helium Collision Mode

Information Dependent Acquisition (IDA) 1

Rapid, simple, interference-free analysis of environmental samples using the XSERIES 2 ICP-MS with 3 rd generation CCT ED

Determination of Phosphorus and Sulfur with Dynamic Reaction Cell ICP-MS

Low Level Detection of Priority Inorganic Pollutants in Water. Anthony Neumann, MSc Darren Crichton, BSc

Techniques for the Analysis of Organic Chemicals by Inductively Coupled Plasma Mass Spectrometry (ICP-MS)

ICP-MS. High Resolution ICP-MS.

Simultaneous quantification of peptides and phosphopeptides by caplc-icp- MS using the Agilent 8800/8900 Triple Quadrupole ICP-MS

Thermo Finnigan LTQ. Specifications

Application Note GA-301E. MBMS for Preformed Ions. Extrel CMS, 575 Epsilon Drive, Pittsburgh, PA I. SAMPLING A CHEMICAL SOUP

Ar Ar + e - INDUCTIVELY+COUPLED+ PLASMA+SPECTROMETRY+ What+is+Plasma?+ FuncDon+of+Plasma+

Introduction to the Q Trap LC/MS/MS System

Sample Analysis Design PART III

Unmatched Removal of Spectral Interferences in ICP-MS Using the Agilent Octopole Reaction System with Helium Collision Mode Application

Theory, Design, and Operation of a Dynamic Reaction Cell for ICP-MS

Thermo Scientific LTQ Orbitrap Velos Hybrid FT Mass Spectrometer

EXPANDING THE CAPABILITIES OF ICP-MS. ELAN DRC-e. Uncompromised sensitivity and performance in a robust system designed for routine laboratories

Analysis of high matrix samples using argon gas dilution with the Thermo Scientific icap RQ ICP-MS

Direct Analysis of Photoresist Using Inductively Coupled Plasma Mass Spectrometry (ICP-MS) Application

Sample Analysis Design PART II

Mass Spectrometry. Quantitative Mass Spectrometry Chiral Mass Spectrometry

TOMAHAQ Method Construction

Interference-free determination of ultra-trace levels of Arsenic and Selenium using methyl fluoride as reaction gas in ICP-MS/MS

vacuum analysis plasma diagnostics surface science gas analysis

Redefining triple quadrupole technology with unique ease of use

An Overview of Magnetic Sector Inductively Coupled ICP and GD-MS. Isaac (Joe) Brenner

Mass Spectrometry in MCAL

SIFT-MS SELECTED ION FLOW TUBE MASS SPECTROMETRY TECHNOLOGY OVERVIEW

Atomic Spectroscopy AA/ICP/ICPMS:

Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry

Inductively Coupled Plasma Mass Spectrometer(ICP-MS)

Transcription:

Agilent s New 8800 ICP-QQQ Transforming ICP-MS Technology 1

8800 ICP-QQQ Key Product Hardware High matrix introduction (HMI) technology Dual conical Extraction and Omega lens focuses ions across the mass range First quad Q1: High frequency hyperbolic quadrupole mass filter selects ions that enter the cell 3 rd generation collision/ reaction cell (ORS 3 ) with up to 4 cell gas lines Low flow sample introduction system 9 orders dynamic range electron multiplier (EM) detector Peltiercooled spray chamber Analyzer quad Q2: High frequency hyperbolic quadrupole selects ions that pass to detector Fast, frequencymatching 27MHz RF generator Robust, high-temperature plasma ion source High-transmission, matrix tolerant interface Efficient twin-turbo vacuum system 2

Presenting the World s First ICP-QQQ World s first Triple Quadrupole ICP-MS (ICP-QQQ) New modes of operation and performance not possible with quadrupole ICP-MS Joins the Agilent 7700, the highest performing quadrupole ICP-MS system Unique capabilities, based on proven technology New Agilent 8800 ICP-QQQ 3

ICP-QQQ and 7700 Series Hardware/Software Agilent ICP-QQQ is a completely new instrument configuration, but shares much hardware and its software platform with the proven 7700. Sample introduction system Plasma RF generator and gas controller Torchbox x/y/z stage Interface Extraction lens; x-lens and s-lens. ORS 3 cell Quadrupole Detector Most of vacuum pump system Common, field-proven hardware and software ensures reliability and supportability. Use of common sample introduction and peripherals allows familiar operation many 7700 methods can be transferred. 4

ICP-QQQ: How Does it Work? ICP (plasma) and Interface: Forms and extracts ions from the sample (just like the 7700) Q1 controls ions that enter the cell Consistent reactions even if sample composition changes ORS 3 collision/ reaction gas added Ions react and are neutralized or moved Product ions are formed Q2 selects the target analyte mass Interference-free analyte ions passed to EM EM (detector): Measures the ions that are scanned by Q2 (just like the 7700) 5

ICP-QQQ: What Can It Do? ICP-QQQ can function in Single-Quad Mode Q1 operates as an ion guide or bandpass filter; can be used in no gas, helium collision mode, reaction mode (just like single quad ICP-MS). Two single-quad modes of operation are available with ICP-QQQ: A. Q1 as an ion guide Allows all ions through, so system works like a conventional ICP-QMS Functions like ICP-QMS with a passive cell B. Q1 as a bandpass filter Allows a window of masses through, above/below the Q2 set mass (mass range can be adjusted by the user) Functions like a single-quad with a scanning cell, except masses outside the bandpass window are rejected before the cell Agilent 8800 ICP-QQQ has ~2x higher sensitivity and >5x lower background than 7700, so DLs are improved even for elements with no interferences ICP-QQQ does everything ICP-QMS can, only better! Plus 6

ICP-QQQ: What Else Can It Do? ICP-QQQ configuration enables MS/MS Mode Q1 set to 1amu resolution, allowing only target ions to enter cell and react: 1. MS/MS On-Mass Mode (Q1 and Q2 both set to the target mass): Q1 allows only the precursor ion mass to enter the cell (analyte and on-mass polyatomics). ORS separates analyte from interference(s). Q2 measures the analyte ion after the on-mass interferences have been removed by reactions in the cell Q1 Rejects all masses except analyte mass (analyte and on-mass interferences) ORS 3 Separates (unreactive) analyte and (reactive) interferences by neutralizing interference or moving it to new mass Q2 Rejects all cellformed ions apart from target analyte ion, leaving analyte free from overlap 7

ICP-QQQ: MS/MS for High-Purity Materials In high-purity materials, the interferences are typically known and consistent. In 10x diluted (9.8%) H 2 SO 4, 2 of the key interfered elements are Ti and V. Ti reacts quickly with NH 3, so a new Ti-NH 3 product ion can be measured, but V reacts slowly, so on-mass measurement is a better solution: Removal of 33 S 18 O + and 34 S 16 OH + overlaps on 51 V + using NH 3 cell gas ICP-QQQ in MS/MS mode allows very effective removal of SO/SOH interferences in NH 3 reaction mode. x10 3 y = 65.9806 * x + 8.5567 R = 0.9999 DL = 0.1308 ppt BEC = 0.1297 ppt No new analyte- or matrix-based NH 3 cluster ions can be created at mass 51, as no other ions are able to enter the cell BEC and DL for V measured directly at mass 51 were both 0.13ppt (130ppq) CPS 5 0 50.0 100.0 Conc(ppt) 8

ICP-QQQ: What Else Can It Do? 2. MS/MS with Mass-Shift (Q1 and Q2 at different mass): Q1 is set to precursor ion mass, controlling the ions that enter ORS. Q2 is set to mass of reaction product ion (Q1 + 16amu in O 2 mode): e.g. Conversion of 32 S + to 48 SO + using O 2 cell gas 32 S 16 O + 33 S 16 O + Single-quad can also do SO mass-shift to move S (as SO + ) away from the O + 34 2 S 16 O + interference. BUT single quad cannot remove the 48 Ca/ 48 Ti and 36 Ar 12 C overlaps on 48 SO + Also, 32 S 18 O + and 34 S 16 O + both appear at mass 50 on single-quad ICP-MS; ICP-QQQ with 16amu mass-shift enables S isotope analysis as only the target S isotope is measured MS/MS provides benefits to both research and real applications and is unique to ICP-QQQ configuration (not possible with single-quad) 9

TiO + Measurement in Conventional ICP-QMS O-atom addition can be used in conventional ICP-QMS as well Ti + TiO + reaction cell chemistry with O 2 cell gas still works without MS/MS 1ppb Ti 1ppb Ti + 10ppb Ni 1ppb Ti + 10ppb Cu 1ppb Ti + 10ppb Zn Ti isotopic pattern Conventional ICP-MS Titanium All TiO + peaks 1ppb are standard overlapped overlaid TiO peaks when with Ni, match 1ppb Cu & Ti Zn + peak 10ppb are templates, present Ni, & Cu Cu& BUT Zn 10

ICP-QQQ: Neutral Gain Scan for TiO; O 2 Cell Gas O-atom addition: Q2 scanned at Q1 mass + 16 to monitor Ti + 16 O transition (for all Ti isotopes). 46 Ti + 62 TiO +, 47 Ti + 63 TiO +, 48 Ti + 64 TiO +, etc. 1ppb Ti Ti 1ppb Ti + 10ppb Ni 1ppb Ti + 10ppb Cu 1ppb Ti + 10ppb Zn Ti isotopic pattern ICP-QQQ in MS/MS Mode Neutral MS/MS mode Gain Scan allows TiO to peaks be measured match Ti as isotopic TiO with template no overlap perfectly from Ni, Cu, Zn 11

8800 Abundance Sensitivity in MS/MS Mode 55 Mn is free from overlap by 56 Fe in 1000ppm Fe QQQ Abundance Sensitivity is the product of Q1 AS x Q2 AS, so overlaps to adjacent peaks are virtually eliminated 8800 QQQ AS is almost too good to measure (<10-9 ) 12

Agilent 8800 ICP-QQQ Key Features Outperforms quadrupole ICP-MS for conventional applications Provides unique, high-performance MS/MS mode QQQ configuration ensures control of ions that enter the cell; controlled reaction processes deliver reliable results Offers ultimate flexibility for problem solving and advanced research Utilizes critical hardware and same MassHunter software platform as the proven 7700, ensuring reliability and supportability (global network of service and applications support) 13

14