MODEL: R7FN. Remote I/O R7 Series FLEX NETWORK I/O MODULE

Similar documents
MODEL: R7K4FML3. Remote I/O R7K4F Series. POWER INPUT DC power R: 24 V DC (Operational voltage range: ±10 %; ripple 10 %p-p max.)

MODEL: R7M. Remote I/O R7 Series MODBUS I/O MODULE

BEFORE USE... POINTS OF CAUTION COMPONENT IDENTIFICATION INSTRUCTION MANUAL MODEL R7K4DH-1-DAC32D R7K4DH-1-DAC32D

POINTS OF CAUTION BEFORE USE...

The Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows:

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

SCTP20 Programmable 2-Wire Temperature Transmitter, Head Mount

E8EB-N0C2B E8EB-N0B2B

BMXART0814 analog input module M340-8 inputs - temperature

16 Input AC Block I/O Module

Safety Precautions WARNING If critical situations that could lead to user s death or serious injury is assumed by mishandling of the product.

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER

SINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol

PHOENIX CONTACT - 04/2016. Features

Pressure. 1 Fitting PA R - N R2

BMXART0814 analog input module M340-8 inputs - temperature

Proximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C

32 Input AC Block I/O Module

ED 701 General Industry Pressure Transmitter

SINEAX VK 626 Programmable Temperature Transmitter for RTD and TC inputs, with HART protocol

THM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist

Remote Display Unit. Installers Handbook Copyright 2001 AirSense Technology Ltd. LM Remote Display Unit Installers Handbook Issue 1.

Digital display Pressure range ON/OFF output Linear output Model No Positive pressure 0 to 98 kpa (0 to 1 kgf/cm 2 ) NPN open collector o 1 to o5

Fitting PS P - B - R2

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure

TF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8.

S95.3U01 / S95.3U11. Head mounted temperature transmitters, programmable, Pt 100 (RTD), thermocouples, electrical isolation

Operating Instructions for Digital Manometer. Model: MAN-SD

TF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

DATA SHEET. Thermocouple module with digital I²C-Interface - THMOD-I²C. Characteristic features. Areas of application. Features.

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

CALYS 80P. Field pressure calibrator with high accuracy 0.01%

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

E2T0 DVP

Multi-function, economical instrument with 4 functions in the same casing. Accessibility and safety: large-dimension terminals Insulated circuits

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006%

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

Thermal-Magnetic Circuit Breaker 2210-S2..

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000

Thermal-Magnetic Circuit Breaker 2210-T2...

Thermal-Magnetic Circuit Breaker 2210-S2..

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

Thermal-Magnetic Circuit Breaker 2210-S2..

Single point load cells

E6C-N. Ideal for Out-of-step Detection of Stepping Motors and Position Control of Rotors and Unloaders

Welcome. Functionality and application of RTD Temperature Probes and Thermocouples. Dipl.-Ing. Manfred Schleicher

Pressure transmitters for industrial applications MBS 32 and MBS 33

Thermal-Magnetic Circuit Breaker 2210-S2...

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

Thermal-Magnetic Circuit Breaker 2210-S2...

S95.3U02 / S95.3U12. Head mounted temperature transmitters, HART programmable, Pt 100 (RTD), thermocouples, electrical isolation

Pressure Display Controller

5SJ4...-.HG Circuit Breakers to IEC and UL 489

BMXART0814 analog input module M340-8 inputs - temperature

Features of Uni-Thermo

xlogic SuperRelay is a compact and expandable CPU replacing mini PLCs, multiple timers, relays and counters.

D5.2 Type. Draw wire mechanics with incremental encoder. Measuring length max. 2 m. Compact and simple. Order code draw wire encoder

Time - timing relays 1 Industrial relays, solid state output, width 22.5 mm

Features of Uni-Thermo

PTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30

Single cam type. Double cam type. Grip force N. Type Model/size Stroke Screw type straight style. Screw type tee style

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...

All part numbers in the coding below start with "TC-" and end with "203"

Technical Description

INTEGRATED CIRCUITS. For a complete data sheet, please also download:

Phototransistor. Industry Standard Single Channel 6 Pin DIP Optocoupler

Linear measuring technology

Field mounted Temperature Transmitter TF212/TF212-Ex

Acceleration/Velocity/Displacement VIBRATION METER

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level

technical bulletin Installation Instructions: Wall-Mount Dewpoint Probe ( )

THERMOCOUPLE CHARACTERISTICS TRAINER

IR 80-H. Non-Contact Infrared Temperature Sensor/Transmitter. Temperature Range: 500~1700

Differential Pressure Sensor

PG-200/PG-208 PRESSURE GAUGES P G G P P

Pressure Transmitter ED 701

TURQUOISE SWITCHES V TYPE (ABV)

SPECIFICATION. Messrs. DATE 20 June, 2013 No. V AP4, AG4 Pressure Sensor

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

T20WN. Data Sheet. Torque transducers. Special features. Installation example with bellows couplings. B en

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.

ABB i-bus KNX Analogue Input AE/A 2.1

473-SHX Dew Point Mirror

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

3-1. Heat Dissipation Design Method. Power Dissipation Loss Calculation Usage of The Cooler with Water Jacket 3-7 Flange Adapter Kit 3-10

Metal Oxide Film Resistors Axial Connections Metal Oxide Film Resistors 1/4W, 5% Components

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011

W 30 Photoelectric proximity switches: Clear signals even with low remission

PC3SD21NTZ Series. VDRM : 600V Zero cross type DIP 6pin Phototriac Coupler for triggering

Acceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202

WT 27 L-2 Laser Photoelectric proximity switches, background suppression -- DC. Dimensional drawing Adjustments possible WT 27L-2F 430

P300. Technical Manual I/Os, 240 solenoid drivers th Street, Davis, CA 95616, USA Tel: Fax:

Digital Current Transducer HO-SW series I P N = A. Ref: HO 100-SW; HO 150-SW; HO 200-SW; HO 250-SW

Connector~Tech Providing Harsh Environment Connector

Non-Contact Safety Systems CMS

Pressure Measurement Single-range transmitters for general applications

Features. Functional Diagrams, Pin Configurations, and Truth Tables

MODEL: CR002, CR003, CR004. ADC12 Display shield. Liquid (Density range: 0.3 to 2.0g/mL) Operating temperature range

Transcription:

MODEL: RFN Remote I/O R Series FLEX NETWORK I/O MODULE /C0: Rubber coating EX-FACTORY SETTING /SET: Preset according to the Ordering Information Sheet (No. ESU-0-x) ORDERING INFORMATION Basic module: RFN-[]-R[] Specify a code from below for each [] and []. (e.g. RFN-DCA-R/Q) Specify the specification for option code /Q (e.g. /C0/SET) MODEL: RFN [] R[] [] I/O TYPE DA: Discrete input, points DCA: NPN transistor output, points DCB: PNP transistor output, points DACA: Discrete input, points NPN transistor output, points DACB: Discrete input, points PNP transistor output, points DCC: Relay contact output, points SV: DC voltage/current input (0 V/0 ma), points SVF: DC voltage/current input (0 V/0 ma), high speed, points, non-isolated (CE not available) TS: Thermocouple input, points RS: RTD input, points YV: DC voltage output, points YS: DC current output, points POWER INPUT DC Power R: V DC [] OPTIONS blank: none /Q: With options (specify the specification) OF OPTION: Q (multiple selections) COATING (For the detail, refer to M-System's web site.) /C0: Silicone coating /C0: Polyurethane coating FUTIONS & FEATURES The RFN interfaces discrete I/O signals with a PLC via FLEX NETWORK. Input sensor type (thermocouple, RTD) and range can be selected with the front DIP switches for all channels. In order to set different selections for individual channels, the PC Configurator Software (model: RCON) is used. The analog modules are compatible with the screen editor GP-Pro EX (Ver..0 or later). For versions between.0 and.0, the driver must be installed. The driver is downloadable at Digital Electronics Corporation's web site. http://www.proface.co.jp/ FLEX NETWORK is registered trademark of Digital Electronics Corporation in Japan. RELATED PRODUCTS PC configurator software (model: RCON) Downloadable at M-System s web site. A dedicated cable is required to connect the module to the PC. Please refer to the internet software download site or the users manual for the PC configurator for applicable cable types. GENERAL Common Specifications Power input: V DC ±0 %; ripple 0 %p-p max. Insulation resistance: 00 MΩ with 00 V DC Dielectric strength: 00 V AC @ minute (Refer to each model for isolated sections.) Operating temperature: -0 to + C ( to F) Operating humidity: 0 to 0 %RH (non-condensing) Atmosphere: No corrosive gas or heavy dust Storage temperature: -0 to + C (- to + F) Mounting: DIN rail ( mm wide) Connection: M separable screw terminals (torque 0. N m) Screw terminal material: Nickel-plated steel Recommended solderless terminal: Communication cable Applicable wire size: 0. to 0. mm (AWG - ) Recommended manufacturer: Japan Solderless Terminal M.Co.Ltd Others Applicable wire size: 0. to. mm (AWG to ) Recommended manufacturer: Japan Solderless Terminal M.Co.,Ltd, Nichifu Co.,Ltd RFN ES-0 Rev.0 Page /

MODEL: RFN Housing material: Flame-resistant resin (gray) Status indicator LEDs: PWR, RUN (Refer to the instruction manual for details) Current Consumption & Weight RFN-DA: Approx. 0 ma, 00 g (0. lb) RFN-DCA: Approx. 0 ma, 00 g (0. lb) RFN-DCB: Approx. 0 ma, 00 g (0. lb) RFN-DACA: Approx. 0 ma, 00 g (0. lb) RFN-DACB: Approx. 0 ma, 00 g (0. lb) RFN-DCC: Approx. 0 ma (approx. 0 ma*), 00 g (0. lb) RFN-SV: Approx. 0 ma, 00 g (0. lb) RFN-SVF: Approx. 0 ma, 00 g (0. lb) RFN-TS: Approx. 0 ma, 00 g (0. lb) RFN-RS: Approx. 0 ma, 00 g (0. lb) RFN-YV: Approx. 00 ma, 00 g (0. lb) RFN-YS: Approx. 0 ma, 00 g (0. lb) * Relay driving current. Recommended solderless terminal. (.) max Measurement Category II (output) Pollution Degree Output to power: Basic insulation (0 V) RoHS Directive EN 0 (.) max mm (inch) FLEX NETWORK COMMUNICATION Communication configuration: : N Connection method: Multi-drop Connection Communication method: Cyclic Time Division, half-duplex Communication I/F: Differential, pulse transfer isolation Error Check: Format, bit, CRC- verification Max. Number of Nodes: (00 I/O points) Network cable: Pro-face s following cable FN-CABLE00--MS (0 m) FN-CABLE00--MS (0 m) FN-CABLE00--MS (00 m) Transmission distance: Mbps: 00 meters ( ft) Mbps: 00 meters ( ft) Station address: Rotary switch (Refer to the instruction manual) Terminating resistor: Built-in STANDARDS & APPROVALS EU conformity: EMC Directive EMI EN 000-- EMS EN 000-- Low Voltage Directive (RFN-DCC only. Refer to the instruction manual for the detailed information.) EN 00-, EN 00--0 RFN ES-0 Rev.0 Page /

MODEL: RFN EXTERNAL VIEW Station Address Setting Rotary SW Status Indicator LED Operating Mode Setting DIP SW (SW) PC Configurator Jack * Discrete I/O Status Indicator LED * PWR RUN X0 X ON 0 A B C D E F F0ABCDE STATION ADD. F0ABCDE CN. 0 Network, Power Supply Terminals I/O Terminals * *. Not available with discrete I/O modules. *. Not available with analog I/O modules. LED through F are not available for -point discrete output modules. *. 0-pin terminal block available with analog output modules. CONNECTION DIAGRAMS NETWORK, POWER SUPPLY TERMINAL ASSIGNMENT TR- +V JP+ JP- NO. ID FUTION, NOTES JP+ Terminating resistor Terminating resistor Network Network +V Power input (V DC) Power input () MASTER CONNECTION Master Station Slave Station Slave Station Terminating Resistor SHIELD JP+ JP+ Terminating Short Bar Note: Be sure to use the terminator(s) located at both ends of the modules. RFN ES-0 Rev.0 Page /

DATA CONVERSION 0 00% DATA CONVERSION Analog input data is converted into digital representations of 0 00% proportional to each scaled range. The converted % values are multiplied by 00 and expressed in bits. Overrange input is possible from - to +% of the nominal range. When the signal exceeds the limit, the data is fixed at -% or +% respectively. Negative value is represented in ʼs complements. Input Range 0 V DC Input Value -0. V 0 V V. V Input % -% 0% 00% % Converted Data, Decimal -00 0 0000 00 Converted Data, Hex FA 0 0 CEC MODEL: RFN 00 (CEC) 0000 (0) -0. 0.0. (V) -00 (FA) Analog output is converted in the reverse order of the input data. The output range 0 V DC is expressed as 0000 at.0 V (00%) and 0 at 0 V (0%). ENGINEERING UNIT CONVERSION Engineering unit value C or K is multiplied by 0 and expressed in bits. F data is represented in engineering unit value, without multiplication. Negative value is represented in ʼs complements. Input TYPE K Thermocouple Input Value - C -0 C 0 C C Converted Data, Decimal -0-00 00 0 Converted Data, Hex F0 FA 0 0 (0) 00 () - -0 0 ( C) -00 (FA) -0 (F0) RFN ES-0 Rev.0 Page /

MODEL: RFN I/O DATA DESCRIPTIONS DISCRETE I/O 0 : OFF : ON 0 DA DCA DCB DACA DACB DCC Input 0 Output 0 Input 0 Output 0 Input Output Input Output Input Output Input Output Input Output Input Output : : : : Input Output Input Output Input Output Output 0 Unused : : : : Input Output Output Unused ANALOG I/O 0 -bit binary data Negative values represented in s complements DIMENSIONS unit: mm (inch) DISCRETE I/O MODULE, ANALOG INPUT MODULE (.) (.) (.) 0 (.). (.) 0 DIN RAIL mm wide (.). (.) M SCREW TERMINALS for Network, POWER For Thermocouple Input 0 (.) [ (.0)] (.) (.) (.) M SCREW TERMINALS for I/O (.) (.) DIN RAIL mm wide 0 (.) [ (.0)] RFN ES-0 Rev.0 Page /

MODEL: RFN ANALOG OUTPUT (.) (.) (.). (.) (.) 0 (.). (.) (.) 0 (.) 0 (.) [ (.0)] DIN RAIL mm wide M SCREW TERMINALS for Network, POWER 0 M SCREW TERMINALS for Output RFN ES-0 Rev.0 Page /

MODEL: RFN DISCRETE INPUT MODULE, points MODEL:RFN DA Common: Positive or negative common (PNP/NPN) per points Number of I/O: Input, points Maximum inputs applicable at once: No limit (at V DC) Input status indicator: LED turns ON with contact ON : Input to FLEX NETWORK to power input to Data allocation: Rated input voltage: V DC ±0 %; ripple %p-p max. ON voltage / current: V DC (input COM) /. ma OFF voltage / current: V DC (input COM) / ma Input current:. ma per point at V DC Input resistance: Approx.. kω ON delay:.0 msec. OFF delay:.0 msec. 0 COM X X0 COM X X X X X X X X XA XB XC XD XE XF Note: In order to improve EMC performance, bond the terminal to ground. Caution: terminal is NOT a protective conductor terminal. COM COM 0 X0 X X X X XA XC XE X X X X X XB XD XF Input JP+ V DC NO. ID FUTION NO. ID FUTION COM Common 0 COM Common X0 Input 0 X Input X Input X Input X Input X Input X Input X Input X Input X Input XA Input 0 XB Input XC Input XD Input XE Input XF Input Input COM COM 0 X0 XF Input Connection Example PNP Connection + COM NPN Connection + COM COM 0 COM 0 X0 X0 XF XF RFN ES-0 Rev.0 Page /

MODEL: RFN NPN TRANSISTOR OUTPUT MODULE, points MODEL:RFN DCA Common: Negative common (NPN) per points Number of I/O: Output, points Maximum outputs applicable at once: No limit (at V DC) Output status indicator: LED turns ON with contact ON : Output to FLEX NETWORK to power input to Data allocation: Rated load voltage: V DC ±0 % Rated output current: 0. A per point,.0 A per common Residual voltage:. V Leakage current: 0. ma ON delay: 0. msec. OFF delay:. msec. (When driving an inductive load, connect a diode in parallel with the load.) Note: In order to improve EMC performance, bond the terminal to ground. Caution: terminal is NOT a protective conductor terminal. JP+ V DC Output 0 +V Y0 Y Y Y Y YA YC YE Y Y Y OPERATING MODE SETTING (*) Factory setting Caution! - SW- through - are unused. Be sure to turn off unused ones. Output at the Loss of Communication (SW-) SW- Output at the loss of communication OFF Hold the output (*) (maintains the last data received normally) ON Reset the output (turned off) 0 + V Y Y0 0 V Y Y Y Y Y Y Y Y YA YB YC YD YE YF NO. ID FUTION NO. ID FUTION 0 V 0 V (common) 0 + V V DC Y0 Output 0 Y Output Y Output Y Output Y Output Y Output Y Output Y Output Y Output Y Output YA Output 0 YB Output YC Output YD Output YE Output YF Output Output Output Connection Example +V 0 Y0 + Y Y YB YD YF 0 +V Y0 YF YF RFN ES-0 Rev.0 Page /

MODEL: RFN PNP TRANSISTOR OUTPUT MODULE, points MODEL:RFN DCB Common: Positive common (PNP) per points Number of I/O: Output, points Maximum outputs applicable at once: No limit (at V DC) Output status indicator: LED turns ON with contact ON : Output to FLEX NETWORK to power input to Data allocation: Rated load voltage: V DC ±0 % Rated output current: 0. A per point,.0 A per common Residual voltage:. V Leakage current: 0. ma ON delay: 0. msec. OFF delay:. msec. (When driving an inductive load, connect a diode in parallel with the load.) Note: In order to improve EMC performance, bond the terminal to ground. Caution: terminal is NOT a protective conductor terminal. JP+ V DC Output 0 +V Y0 Y Y Y Y YA YC YE Y Y Y Y OPERATING MODE SETTING (*) Factory setting Caution! - SW- through - are unused. Be sure to turn off unused ones. Output at the Loss of Communication (SW-) SW- Output at the loss of communication OFF Hold the output (*) (maintains the last data received normally) ON Reset the output (turned off) Output 0 +V Y YB YD YF 0 + V Y Y0 0 V Y Y Y Y Y Y Y Y YA YB YC YD YE YF Y0 YF NO. ID FUTION NO. ID FUTION 0 V 0 V 0 + V V DC (common) Y0 Output 0 Y Output Y Output Y Output Y Output Y Output Y Output Y Output Y Output Y Output YA Output 0 YB Output YC Output YD Output YE Output YF Output Output Connection Example +V 0 + Y0 YF RFN ES-0 Rev.0 Page /

MODEL: RFN DISCRETE INPUT & NPN TRANSISTOR OUTPUT MODULE, points each MODEL:RFN DACA COMMON Common: Negative common (NPN) per points Number of I/O: Input, points; Output, points Maximum I/O applicable at once: No limit (at V DC) I/O status indicator: LED turns ON with contact ON : Input or output to FLEX NETWORK to power input to Data allocation: INPUT Rated input voltage: V DC ±0 %; ripple %p-p max. ON voltage/current: V DC (input-com) /. ma OFF voltage/current: V DC (input-com) / ma Input current:. ma per point at V DC Input resistance: Approx.. kω ON delay:.0 msec. OFF delay:.0 msec. OUTPUT Rated load voltage: V DC ±0 % Rated output current: 0. A per point,.0 A per common Residual voltage:. V Leakage current: 0. ma ON delay: 0. msec. OFF delay:. msec. (When driving an inductive load, connect a diode in parallel with the load.) NO. ID FUTION NO. ID FUTION COM Common 0 +V V DC X0 Input 0 X Input X Input X Input X Input X Input X Input X Input Y0 Output 0 Y Output Y Output Y Output Y Output Y Output Y Output Y Output OPERATING MODE SETTING (*) Factory setting Caution! - SW- through - are unused. Be sure to turn off unused ones. Output at the Loss of Communication (SW-) SW- Output at the loss of communication OFF Hold the output (*) (maintains the last data received normally) ON Reset the output (turned off) RFN ES-0 Rev.0 Page 0/

MODEL: RFN Note: In order to improve EMC performance, bond the terminal to ground. Caution: terminal is NOT a protective conductor terminal. Input COM X0 JP+ X X X V DC X X X X Y0 Y Y Y Y Y Y Y Output 0 +V Input COM X0 X Output 0 +V Y0 Y COM I/O Connection Example +V 0 COM + X0 X Y0 Y RFN ES-0 Rev.0 Page /

MODEL: RFN DISCRETE INPUT & PNP TRANSISTOR OUTPUT MODULE, points each MODEL:RFN DACB COMMON Common: Positive common (PNP) per points Number of I/O: Input, points; Output, points Maximum I/O applicable at once: No limit (at V DC) I/O status indicator: LED turns ON with contact ON : Input or output to FLEX NETWORK to power input to Data allocation: INPUT Rated input voltage: V DC ±0 %; ripple %p-p max. ON voltage/current: V DC (input-com) /. ma OFF voltage/current: V DC (input-com) / ma Input current:. ma per point at V DC Input resistance: Approx.. kω ON delay:.0 msec. OFF delay:.0 msec. OUTPUT Rated load voltage: V DC ±0 % Rated output current: 0. A per point,.0 A per common Residual voltage:. V Leakage current: 0. ma ON delay: 0. msec. OFF delay:. msec. (When driving an inductive load, connect a diode in parallel with the load.) NO. ID FUTION NO. ID FUTION COM Common 0 +V V DC X0 Input 0 X Input X Input X Input X Input X Input X Input X Input Y0 Output 0 Y Output Y Output Y Output Y Output Y Output Y Output Y Output OPERATING MODE SETTING (*) Factory setting Caution! - SW- through - are unused. Be sure to turn off unused ones. Output at the Loss of Communication (SW-) SW- Output at the loss of communication OFF Hold the output (*) (maintains the last data received normally) ON Reset the output (turned off) RFN ES-0 Rev.0 Page /

MODEL: RFN Note: In order to improve EMC performance, bond the terminal to ground. Caution: terminal is NOT a protective conductor terminal. Input 0 +V X0 JP+ X X X V DC X X X X Y0 Y Y Y Y Y Y Y Output COM Input +V 0 X0 X Output 0 +V Y0 Y COM I/O Connection Example +V 0 + COM X0 X Y0 Y RFN ES-0 Rev.0 Page /

MODEL: RFN RELAY CONTACT OUTPUT MODULE, points MODEL:RFN DCC Common: common per points ( terminals) Maximum current load:.0 A per point Common current: Max. A ( terminals) Number of I/O: Relay contact output, points Maximum outputs applicable at once: No limit (at V DC) Output status indicator: LED turns ON with contact ON : Output to FLEX NETWORK to power input to Data allocation: Relay driving power: V DC ±0 %, 0 ma Rated load: 0 V AC* @ A (cos ø = ) 0 V DC @ A (resistive load) Electrical life 0 cycles (rate 0/min.) *Limited to the max. voltage V AC or to the use for Measurement Category I in order to conform with EU Directive. Maximum switching voltage: 0 V AC or 0 V DC Maximum switching power: 0 VA or 0 W Minimum load: V DC @ ma Mechanical life: 0 cycles (rate 00/min.) When driving an inductive load, external contact protection and noise quenching are recommended. ON delay: 0 msec. OFF delay: 0 msec. OPERATING MODE SETTING (*) Factory setting Caution! - SW- through - are unused. Be sure to turn off unused ones. Output at the Loss of Communication (SW-) SW- Output at the loss of communication OFF Hold the output (*) (maintains the last data received normally) ON Reset the output (turned off) NO. ID FUTION NO. ID FUTION 0 V 0 V 0 + V V DC Common 0 Y0 Output 0 Common 0 Y Output Common 0 Y Output Common 0 Y Output COM Common Y Output COM Common Y Output COM Common Y Output COM Common Y Output Note: In order to improve EMC performance, bond the terminal to ground. Caution: terminal is NOT a protective conductor terminal. JP+ V DC Output Connection Example points / common points / common +V 0 V DC + +V 0 Ry Ry Ry Ry Ry Ry Ry Ry V DC + Y0 Y Y Y Y Y Y Y COM COM COM COM 0 +V 0 + V Y0 0 V Y Y Y Y COM Y COM Y COM Y COM Y0 Y Y Y COM COM + + + + Y0 Y Y Y COM COM + + RFN ES-0 Rev.0 Page /

MODEL: RFN DC VOLTAGE/CURRENT INPUT MODULE, points MODEL: RFN SV : Input 0 to input to input to input to FLEX NETWORK to power input to Data allocation: Converted data range: 0 0000 of the input range Input range Wide span voltage: -0 +0 V DC, - + V DC, 0 0 V DC, 0 V DC, V DC Narrow span voltage: - + V DC, 0 V DC, -0. +0. V DC Current range: -0 +0 ma DC, 0 0 ma DC, 0 ma DC Input resistance Wide span voltage: MΩ Narrow span voltage: 00 kω Current range: 0 Ω Conversion rate / conversion accuracy: 0 msec./±0. %, 0 msec./±0. %, 0 msec./±0. %, 0 msec./±0. % Response time: Conversion rate + 0 msec. (0 0 %) Temperature coefficient: ±0.0 %/ C (±0.00 %/ F) OPERATING MODE SETTING (*) Factory setting Caution! - SW-, SW- and SW- are unused. Be sure to turn off unused ones. Input Range (SW-, -, -, -) SW- SW- SW- SW- Input range OFF OFF OFF OFF -0 + DC (*) ON OFF OFF OFF - +V DC OFF ON OFF OFF - +V DC ON ON OFF OFF 0 DC OFF OFF ON OFF 0 V DC ON OFF ON OFF V DC OFF ON ON OFF 0 V DC ON ON ON OFF -0. +0.V DC ON OFF OFF ON -0 +0mA DC OFF ON OFF ON 0mA DC ON ON OFF ON 0 0mA DC ON ON ON ON PC Confi gurator setting VH0 0 VL0 I0 VH VL I COM VH VL I COM VH VL I COM NO. ID FUTION NO. ID FUTION VH0 Wide span volt. 0 0 VL0 Narrow span volt. 0 Common 0 I0 Current range 0 VH Wide span volt. VL Narrow span volt. COM Common I Current range No connection No connection VH Wide span volt. VL Narrow span volt. COM Common I Current range VH Wide span volt. VL Narrow span volt. COM Common I Current range Note: In order to improve EMC performance, bond the terminal to ground. Caution: terminal is NOT a protective conductor terminal. INPUT 0 VH0 VL0 0 I0 INPUT VH VL I COM INPUT VH VL I COM INPUT VH VL I COM Input Input Input Input JP+ V DC Input Connection Examples + VHn VHn VHn WIDE SPAN VOLTAGE VLn In NARROW SPAN VOLTAGE + VLn + In CURRENT RANGE VLn In COMn COMn COMn Be sure to close across VLn and In terminals for a current input. RFN ES-0 Rev.0 Page /

MODEL: RFN DC VOLTAGE/CURRENT INPUT MODULE, points (high speed, non-isolated) MODEL: RFN SVF VH0 0 VL0 I0 VH VL I COM VH VL I COM VH VL I COM : Input to FLEX NETWORK to power input to Data allocation: Converted data range: 0 0000 of the input range Input range Wide span voltage: -0 +0 V DC, - + V DC, 0 0 V DC, 0 V DC, V DC Narrow span voltage: - + V DC, 0 V DC, -0. +0. V DC Current range: -0 +0 ma DC, 0 0 ma DC, 0 ma DC Input resistance Wide span voltage: > MΩ Narrow span voltage: > 00 kω Current range: 0 Ω Moving average: No averaging,,, samples (Selectable with PC Configurator Software) Conversion rate/conversion accuracy: msec./±0. % Response time: Conversion rate + scan time (0 0 %) Scan time depends on the Final Satellite (FS) value of Center IC (master) configuration and transfer rate (TBPS). It is calculated with the following formula. Scan time = FS TBPS (seconds) E.g) When Final satellite value =, transfer rate = Mbps, scan time is = / M =. msec. Temperature coefficient: ±0.0 %/ C (±0.00 %/ F) OPERATING MODE SETTING (*) Factory setting Caution! - SW-, SW- and SW- are unused. Be sure to turn off unused ones. Input Range (SW-, -, -, -) SW- SW- SW- SW- Input range OFF OFF OFF OFF -0 + DC (*) ON OFF OFF OFF - +V DC OFF ON OFF OFF - +V DC ON ON OFF OFF 0 DC OFF OFF ON OFF 0 V DC ON OFF ON OFF V DC OFF ON ON OFF 0 V DC ON ON ON OFF -0. +0.V DC ON OFF OFF ON -0 +0mA DC OFF ON OFF ON 0mA DC ON ON OFF ON 0 0mA DC ON ON ON ON PC Confi gurator setting NO. ID FUTION NO. ID FUTION VH0 Wide span volt. 0 0 VL0 Narrow span volt. 0 Common 0 I0 Current range 0 VH Wide span volt. VL Narrow span volt. COM Common I Current range No connection No connection VH Wide span volt. VL Narrow span volt. COM Common I Current range VH Wide span volt. VL Narrow span volt. COM Common I Current range INPUT 0 VH0 VL0 0 I0 INPUT VH VL I COM INPUT VH VL I COM INPUT VH VL I COM Input Connection Examples WIDE SPAN VOLTAGE + VHn VLn In COMn Input Input Input Input NARROW SPAN VOLTAGE VHn In COMn Be sure to close across VLn and In terminals for a current input. JP+ VHn + VLn + VLn CURRENT RANGE In COMn V DC RFN ES-0 Rev.0 Page /

MODEL: RFN THERMOCOUPLE INPUT MODULE, points MODEL: RFN TS : Input 0 to input to input to input to FLEX NETWORK to power input to Data allocation: Converted data range: Engineering unit value ( C, K) 0 (integer); No multiplication for F Linearization: Standard Thermocouple: K, E, J, T, B, R, S, C, N, U, L, P, PR Cold junction compensation: CJC sensor attached to the input terminals Input resistance: 0 kω Burnout sensing: 0. μa Conversion accuracy: ± C (±. F); ±.0 C (±. F) for B, R, S, C, PR Conversion rate: 0 msec. or 00 msec. Response time: Conversion rate + 0 msec. (0 0 %) Temperature coefficient: ±0.0 %/ C (±0.00 %/ F) of max. span CJC error: ±.0 C at C ±0 C (±. F at F ± F) ±. C (±. F) for R, S, PR T/C BURNOUT INDICATION ( C) Downscale Upscale CONFORMAE RANGE ( C) K (CA) - + -0 to +0 E (CRC) - +0-0 to +000 J (IC) -0 +00-0 to +00 T (CC) - + 00-0 to + 00 B (RH) 0 000 to 0 R -00 +0 0 to 0 S -00 +0 00 to 0 C (WRe -) - + 00 to N - +00-0 to +00 U - + 00-00 to +00 L - +000-00 to +00 P (Platinel II) - + 0 to (PR) - +0 00 to 0 BURNOUT T/C CONFORMAE INDICATION ( F) RANGE ( F) Downscale Upscale K (CA) - + - to + E (CRC) - +0 - to + J (IC) - + - to + T (CC) - + - to + B (RH) to 00 R - +0 to 00 S - +0 to 00 C (WRe -) - + to N - + -0 to + U - + - to + L - + - to + P (Platinel II) - + to (PR) - +0 to 00 OPERATING MODE SETTING (*) Factory setting Caution! - SW- and SW- are unused. Be sure to turn off unused ones. Thermocouple Type (SW-, -, -, -) SW- SW- SW- SW- Thermocouple type OFF OFF OFF OFF K (CA) (*) ON OFF OFF OFF E (CRC) OFF ON OFF OFF J (IC) ON ON OFF OFF T (CC) OFF OFF ON OFF B (RH) ON OFF ON OFF R OFF ON ON OFF S ON ON ON OFF C (WRe -) OFF OFF OFF ON N ON OFF OFF ON U OFF ON OFF ON L ON ON OFF ON P (Platine II) OFF OFF ON ON (PR) ON ON ON ON PC Configurator setting Burnout (SW-) SW- Burnout OFF Upscale (*) ON Downscale 0 +IN0 IN0 +IN CJ0 +CJ +CJ0 IN CJ +IN IN CJ +CJ +IN +CJ CJ IN NO. ID FUTION NO. ID FUTION +CJ0 CJC + 0 0 +IN0 T/C + 0 CJ0 CJC 0 IN0 T/C 0 +CJ CJC + +IN T/C + CJ CJC IN T/C No connection No connection +CJ CJC + +IN T/C + CJ CJC IN T/C +CJ CJC + +IN T/C + CJ CJC IN T/C RFN ES-0 Rev.0 Page /

MODEL: RFN Note: In order to improve EMC performance, bond the terminal to ground. Caution: terminal is NOT a protective conductor terminal. INPUT 0 +IN0 IN0 0 Input +CJ0 JP+ CJ0 INPUT +IN Input IN V DC +CJ CJ INPUT +IN Input IN +CJ CJ INPUT +IN Input IN +CJ CJ Input Connection Example T/C + +INn INn CJC SENSOR +CJn CJn RFN ES-0 Rev.0 Page /

MODEL: RFN RTD INPUT MODULE, points MODEL: RFN RS : Input 0 to input to input to input to FLEX NETWORK to power input to Data allocation: Converted data range: Engineering unit value ( C, K) 0 (integer); No multiplication for F Linearization: Standard RTD: Pt 00 (JIS, IEC), Pt 00 (JIS ), JPt 00 (JIS ), Pt 0 Ω (JIS ), Ni 00, Cu 0, Cu 0 Sensing current: ma Input resistance: MΩ Maximum leadwire resistance: 00 Ω per wire Conversion accuracy: ± C (±. F); ± C (±. F) for Cu 0 Conversion rate: 0 msec. or 00 msec. Response time: Conversion rate + 0 msec. (0 0 %) Temperature coefficient: ±0.0 %/ C (±0.00 %/ F) of max. span RTD BURNOUT INDICATION ( C) CONFORMAE Downscale Upscale RANGE ( C) Pt 00 (JIS, IEC) -0 +00-00 to +0 Pt 00 (JIS ) -0 +00-00 to +0 JPt 00 (JIS ) - +0-00 to +0 Pt 0 Ω (JIS ) - +00-00 to + Ni 00-00 + -0 to +0 Cu 0 @ C - + -0 to +0 Cu 0-00 +00-0 to +0 RTD BURNOUT INDICATION ( F) CONFORMAE Downscale Upscale RANGE ( F) Pt 00 (JIS, IEC) -00 + - to + Pt 00 (JIS ) -00 + - to +0 JPt 00 (JIS ) - +00 - to +0 Pt 0 Ω (JIS ) - + - to +00 Ni 00 - + - to + Cu 0 @ C -0 + - to + Cu 0 - + - to +0 OPERATING MODE SETTING (*) Factory setting Caution! - SW- and SW- are unused. Be sure to turn off unused ones. RTD Type (SW-, -, -, -) SW- SW- SW- SW- RTD Type OFF OFF OFF OFF Pt 00 (JIS, IEC) (*) ON OFF OFF OFF Pt 00 (JIS ) OFF ON OFF OFF JPt 00 (JIS ) ON ON OFF OFF Pt 0Ω (JIS ) OFF OFF ON OFF Ni 00 ON OFF ON OFF Cu 0 @ C OFF OFF OFF ON Cu 0 ON ON ON ON PC Confi gurator setting Burnout (SW-) SW- Burnout OFF Upscale (*) ON Downscale 0 INA0 INb0 INA INB0 INb INB INA INb INB INA INB INb NO. ID FUTION NO. ID FUTION No connection 0 INA0 RTD 0-A INB0 RTD 0-B INb0 RTD 0-b No connection INA RTD -A INB RTD -B INb RTD -b No connection No connection No connection INA RTD -A INB RTD -B INb RTD -b No connection INA RTD -A INB RTD -B INb RTD -b RFN ES-0 Rev.0 Page /

MODEL: RFN Note: In order to improve EMC performance, bond the terminal to ground. Caution: terminal is NOT a protective conductor terminal. INPUT 0 INA0 0 INB0 INb0 INPUT INA Input Input JP+ INB INb INPUT INA Input V DC INB INb INPUT INA Input INB INb Input Connection Example RTD A INAn B B INBn INbn RFN ES-0 Rev.0 Page 0/

MODEL: RFN DC VOLTAGE OUTPUT MODULE, points MODEL: RFN YV : Output 0 to output to power input to FLEX NETWORK to Data allocation: Converted data range: 0 0000 of the output range Output range Wide span voltage: -0 +0 V DC, - + V DC, 0 0 V DC, 0 V DC, V DC Narrow span voltage: - + V DC, 0 V DC, -0. +0. V DC Operational range: - + % of the output range (except -0 +0 V DC); approx. -. +. V DC (-0 +0 V DC) Load resistance: 00 kω Conversion accuracy: ±0. % Response time: 0 msec. (0 0 %) Temperature coefficient: ±0.0 %/ C (±0.00 %/ F) OPERATING MODE SETTING (*) Factory setting Caution! - SW- and SW- are unused. Be sure to turn off unused ones. Output Range (SW-, -, -, -) SW- SW- SW- SW- Output range OFF OFF OFF OFF -0 + DC (*) ON OFF OFF OFF - +V DC OFF ON OFF OFF - +V DC ON ON OFF OFF 0 DC OFF OFF ON OFF 0 V DC ON OFF ON OFF V DC OFF ON ON OFF 0 V DC ON ON ON OFF -0. +0.V DC ON ON ON ON PC Confi gurator setting Output at the Loss of Communication (SW-) SW- Output at the loss of communication OFF Hold the output (*) (maintains the last data received normally) ON Reset the output (to -% or approx. -. V DC) VH0 VL0 VH COM 0 VL COM NO. ID FUTION NO. ID FUTION No connection No connection Common 0 VH0 Wide span volt. 0 Common 0 VL0 Narrow span volt. 0 COM Common VH Wide span volt. COM Common 0 VL Narrow span volt. Note: In order to improve EMC performance, bond the terminal to ground. Caution: terminal is NOT a protective conductor terminal. JP+ V DC Output Connection Examples VHn VLn + COMn WIDE SPAN VOLTAGE VHn Output OUTPUT 0 VH0 Output OUTPUT VH VLn + NARROW SPAN VOLTAGE COMn 0 VL VL0 COM COM RFN ES-0 Rev.0 Page /

MODEL: RFN DC CURRENT OUTPUT MODULE, points MODEL: RFN YS : Output 0 to output to power input to FLEX NETWORK to Data allocation: Converted data range: 0 0000 of the output range Output range: 0 ma DC Load resistance: 00Ω Conversion accuracy: ±0. % Response time: 0 msec. (0 0 %) Temperature coefficient: ±0.0 %/ C (±0.00 %/ F) OPERATING MODE SETTING (*) Factory setting Caution! - SW- through - are unused. Be sure to turn off unused ones. Output at the Loss of Communication (SW-) SW- Output at the loss of communication OFF Hold the output (*) (maintains the last data received normally) ON Reset the output (to -%) Note: In order to improve EMC performance, bond the terminal to ground. Caution: terminal is NOT a protective conductor terminal. JP+ V DC Output Output OUTPUT I 0 OUTPUT 0 I0 COM I0 I COM 0 NO. ID FUTION NO. ID FUTION No connection No connection Common 0 I0 Current 0 No connection No connection COM Common I Current No connection 0 No connection RFN ES-0 Rev.0 Page /

MODEL: RFN Specifications are subject to change without notice. RFN ES-0 Rev.0 Page /