Thermal monitoring of dams and levees

Similar documents
ASSESSMENT OF DAMS AND DIKES BEHAVIOR WITH A FIBRE OPTICS BASED MONITORING SOLUTION

Thermal Monitoring of Embankment Dams by Fiber Optics

Numerical modelling of levee stability based on coupled mechanical, thermal and hydrogeological processes

Data Verification, Analytics and Visualization

Embankment dam seepage assessment by resistivity monitoring

ICOLD Bulletin 164 on internal erosion of dams, dikes and levees and their foundations

Smart levees a new future for flood management?

Validation of Sellmeijer s model for backward piping under dikes on multiple sand layers. Vera van Beek Qiuling Yao Meindert Van Frans Barends

design, construction, operation, and maintenance of the BAP is consistent with recognized and generally accepted good engineering standards.

Investigation of shallow leakage zones in a small embankment dam using repeated resistivity measurements

COMPARISION OF HYDRAULIC GRADIENT AND UPLIFT PRESSURE IN THREE TYPES OF DAMS: HOMOGENEOUS, HETEROGENEOUS EARTHFILL DAMS AND CONCRETE GRAVITY DAM

WP2.1 BREACH FORMATION LARGE SCALE EMBANKMENT FAILURE

A Probabilistic Framework for solving Inverse Problems. Lambros S. Katafygiotis, Ph.D.

Photo: Courtesy of US Bureau of Reclamation

PROBLEMS AND SOLUTIONS THAT MAY EMERGE IN THE FOUNDATION AND BODY OF A HOMOGENEOUS FILL DAM ON A WEAK CLAYEY-SILTY-SANDY FORMATION ÇIKRIKÇI DAM

INTERNAL EROSION OF EXISTING DAMS, LEVEES AND DIKES, AND THEIR FOUNDATIONS BULLETIN 164

WHAT SEISMIC HAZARD INFORMATION THE DAM ENGINEERS NEED FROM SEISMOLOGISTS AND GEOLOGISTS?

A Simple Procedure for Estimating Loss of Life from Dam Failure. Wayne J. Graham, P.E. 1

CCR Rule Annual Inspection Report (cont.) 2

Detection of Internal Erosion and Piping in Embankment Dams

Dam failures by erosion: lessons from ERINOH data bases

Modeling Great Britain s Flood Defenses. Flood Defense in Great Britain. By Dr. Yizhong Qu

Countermeasure Calculations and Design

TABLE OF CONTENTS LIST OF TABLES. Page

Sacramento River Bank Protection Project

Todd N. Loar, PG, CEG

RESERVOIR DRAWDOWN RATES/RESERVOIR DRAWDOWN TEST Iron Gate, Copco (I & II), and JC Boyle Dams

Monitoring and Change Detection along the Eastern Side of Qena Bend, Nile Valley, Egypt Using GIS and Remote Sensing

Pirai river (Bolivia)

River Embankment Failure due to Overtopping - In Case of Non-cohesive Sediment -

Geosynthetics Applications and Performance Reviews Select Case Histories

*** ***! " " ) * % )!( & ' % # $. 0 1 %./ +, - 7 : %8% 9 ) 7 / ( * 7 : %8% 9 < ;14. " > /' ;-,=. / ١

Assessment of heterogeneity of an internal structure of an earth-fill embankment with 2-D resistivity survey

Studia Geotechnica et Mechanica, Vol. XXXVI, No. 4, 2014 DOI: /sgem TECHNICAL NOTE

January 17, 2008 File:

Internal erosion processes: experimental characterizations and energy based interpretative method

ICOLD TCDS - Technical Committe on Dam Surveillance

Georadar Application for Dam Safety Study (Case Study of Selorejo Dam)

Practical methodology for inclusion of uplift and pore pressures in analysis of concrete dams

STABILITY ANALYSIS OF EARTH DAM SLOPES SUBJECTED TO EARTHQUAKE USING ERT RESULTS INTERPRETATION

Tailings Dams Monitoring in Swedish Mines using Self-Potential and Electrical Resistivity Methods

Numerical Hydraulics

Gotechnical Investigations and Sampling

Anisotropy in Seepage Analyses

Luca Palmieri Thom Bogaard Miguel Gonzalez-Herraez Alessandro Pasuto. Water JPI WaterWorks2014 Cofunded Call 18 May 2016, Rome

Assessing the vulnerability of a typical British embankment dam to internal erosion

FRED BURR DAM FEASIBILITY STUDY

EXPERIMENTAL STUDY ON RIVER DYKE BREACH CHARACTERISTICS DUE TO OVERTOPPING

[1] Performance of the sediment trap depends on the type of outlet structure and the settling pond surface area.

1 PROJECT BACKGROUND. August 14, Alberta Transportation Central Region #401, Street Red Deer, Alberta T4N 6K8

CENTRAL REGION GEOHAZARDS RISK ASSESSMENT SITE INSPECTION FORM

Rebuilding Flood-Conscious Society

Programmatic Approaches to Assessing and Mitigating Risk to Pipelines from Natural Forces

Limited Visual Dam Safety Inspections OA Oahu Reservoir No Oahu, Hawaii

GEOTECHNICAL ENGINEERING II. Subject Code : 06CV64 Internal Assessment Marks : 25 PART A UNIT 1

Born in Unzen The World s First Unmanned Construction of Multilayer Sediment Control Dam Using Sediment Forms Unzen Restoration Project Office

Presented at the FIG Congress 2018, May 6-11, 2018 in Istanbul, Turkey

Degradation Concerns related to Bridge Structures in Alberta

Calibration of Seepage and Stability Models for analysis of Dams and Levees. Francke C Walberg Consulting Geotechnical Engineer, AECOM

Seismic Analysis of Siri Dam Using Pseudo-Static Approach

Systematic Approach for Solving Flood and Erosion Problem of Assam: A 100 Days Programme

Geophysical Assessment of Dam Infrastructure: the Mugdock Reservoir Dam Case Study

Seepage Analysis for Shurijeh Reservoir Dam Using Finite Element Method. S. Soleymani 1, A. Akhtarpur 2

Amistad Dam Investigation and Oversight: Karst- Founded Dam on the USA-Mexico Border

Effect of River Levee with Geosynthetic- Reinforced Soil against Overflow Erosion and Infiltration

ONYX -MCE MULTI-CHANNEL OPTICAL FIBER PYROMETERS WITH ACTIVE EMISSIVITY COMPENSATION PRECISION TEMPERATURE MEASUREMENT FOR DEMANDING INDUSTRIAL

SONIC PULSE VELOCITY TESTING TO ASSESS CONDITION OF A CONCRETE DAM

Design of Safety Monitoring and Early Warning System for Buried Pipeline Crossing Fault

PERENNIAL PROBLEM OF EARTHEN BUND OF WELLINGDON RESERVOIR. ANALYSIS OF CAUSES AND REMEDIAL MEASURES A CASE STUDY.

GIS Application in Landslide Hazard Analysis An Example from the Shihmen Reservoir Catchment Area in Northern Taiwan

International Journal of Scientific & Engineering Research, Volume 8, Issue 2, February ISSN

Rock & Aggregate Drop Inlet Protection

V-NOTCH _ V-NOTCH FLOW METERS HYDROLOGICAL INSTRUMENTS

RESEARCH ON CAUSE OF DAM FAILURE FROM VIEWPOINT OF HYDRAULIC FRACTURING CASE STUDY OF A DAM FAILURE IN VIETNAM

CEMEX Eliot Quarry. Lake A Evaluation Report. Alameda County, California

Seismic Design of a Hydraulic Fill Dam by Nonlinear Time History Method

Contribution of new technologies for the monitoring of hydraulic plants: the EDF experience

Appendix F Channel Grade Control Structures

Rock Sizing for Waterway & Gully Chutes

Civil Engineering Department College of Engineering

PIZZI FRANCO via Ripoli, 207/E Firenze - Italy. Instruments and Systems for Dam Monitoring and Structural Controls

Benchmarking of Hydrodynamic Models for Development of a Coupled Storm Surge Hazard-Infrastructure Modeling Method to improve Inundation Forecasting

This report was prepared by Klohn Crippen Consultants Ltd. for Alberta Transportation Central Region under Contract No. CE053/2000.

A SIMPLE GIS METHOD FOR OBTAINING FLOODED AREAS

Acoustic Emission Source Identification in Pipes Using Finite Element Analysis

Yev Kontar. Illinois State Geological Survey, University of Illinois at Urbana-Champaign

Risk and Safety in Civil, Surveying and Environmental Engineering

Attachment 3: Fragility Curve Determinations DRAFT

LOADS ON EARTH-FILL AND ROCK-FILL DAMS ARISING FROM WATER AND WIND

GEOL 1121 Earth Processes and Environments

Natural Hazards Large and Small

Changes in soil deformation and shear strength by internal erosion

TAKING THE MYSTERY OUT OF USACE S ER DRILLING IN EARTH EMBANKMENT DAMS AND LEVEES

RISK ASSESSMENT METHODOLOGIES FOR LANDSLIDES

Coastal flood protection systems Xynthia feedback experience. Case studies conclusion

An Introduction to Insulation Resistance Testing

The Russian Practice of Assessment of Earth Dam Seepage Strength

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

J. Paul Guyer, P.E., R.A.

1. The Challenges of the feasibility study

Transcription:

Thermal monitoring of dams and levees Krzysztof Radzicki Cracow University of Technology (Poland) Bonelli Stephane - IRSTEA (France) Barcelona, 2016

Statistics of damming structures collapses due to internal erosion processes Earth dams (World, several years) Foster, 2000 46% Collapse of dike in Cracow Bend of Vistula (2010) The failure occurred at night No recent signs of danger Flood protection dikes / levees (Poland, flood 2010r) Kledyński et all. 2012 30%

Internal erosion SUFFUSION CONTACT EROSION Risk of piping BACKWARD EROSION CONCENTRATED LEAKS High risk of piping PIPING

The problem of piping detection and monitoring Visual inspections, spot geotechnical studies, geophysical surveys, spot sensor monitoring (if it exists), are not sufficient to reliably detect and assess the development of erosion processes especially in the early stages of their development, and especially during the floods to keep levees safe! The frequency of piping failures is significantly higher on first filling and early in the life of the dam. FOSTER et al.. (2000 - The statistics of embankment dam failures and accidents.) In the majority of failures, breaching of the dam occurred within 12 h from initial visual indication of piping developing, and in many cases this took less than 6 h. FOSTER et al.. (2000 - A method for assessing the relative likelihood of failure of embankment dams by piping.)

The problem of reliable condition assessments and monitoring of EARTH DAMS The necessity to minimize the probability of dam collapse Aging of dams Internal erosion is one of the main threats to the safety of dams Shortage of decision support tool for the identification of sections requiring renovation Assessment of dams state based on spot measurements 100m high Teton dam (1976) collapse in 3 hours due to piping

The problem of reliable condition assessments and monitoring of LEVEES The necessity to minimize the probability of disaster of dikes protecting valuable areas particularly urban and industrial Often poor condition of existing levees Shortage of methods for identification of vulnerable sections, especially in the early stages of development of erosion processes, especially the piping Shortage of diagnostic tools enabling automatic detection of internal erosion threats during flood defense Shortage of methods to assess the most vulnerable sections of levees among all the sections where leakages were detected Shortage of decision support tools for identification of critical sections of levee after the flood that require immediate repair Condition assessment of the levee based on spot, usually geotechnical measurements Often a development of internal erosion is from flood to flood ICOLD bulettin B164 (2013)

EWG ICOLD recommendations European Working Group on Internal Erosion of ICOLD ICOLD s Bulletin no 164 (2013): INTERNAL EROSION OF EXISTING DAMS, LEVEES AND DIKES, AND THEIR FOUNDATIONS VOL.1 INTERNAL EROSION PROCESSES AND ENGINEERING ASSESSMENT <Many less direct means of detecting seepage are now available. The most promising is temperature measurement which can be used to infer localized flow. Fiber optic cables facilitate data collection and make it possible to cover large parts of the dam. Remote sensing options also offer great potential in detecting whether the seepage has caused erosion. These will be discussed in detail in Volume 2 of the Bulletin.> Jean-Jacques FRY (2012), the chairman of ICOLD European Working Group on Internal Erosion - 80th ICOLD annual meeting in Kioto PAPER : HOW TO PREVENT EMBANKMENTS FROM INTERNAL EROSION FAILURE? <In our opinion, Distributed Fibre Optic Temperature measurement is the best method. Remote control monitoring of temperature by fibre optic is the only method available for practical application, which has been used successfully during the last 10 years during the last 10 years in Germany, Sweden and France> <The IJkdijk-piping tests clearly demonstrate the reliability and the capabilities of the fiber optic system to detect the early stage of a piping process.>

Coupled heat and water transport DIFFUSION-ADVECTION EQUATION C Θ T t T T + Cq λ = f x Θ x 2 0 SYSTEM NONDIMENTIONAL x x = t L q = const. 2 L = D t DΘ T T T Pe + = t x x Θ 2 0 = λ Θ C Θ Depth [m] Peclet number advection CΘqL Pe = = conduction λ Conduction domination Pe < 1 LEAKAGE ZONE Θ Advection domination Pe >1 Temperature [ºC] Distance [m]

Example of the impact of internal erosion development on the temperature field in the damming structure Radzicki and Bonelli (2012)

Methods of temperature measurements Leak Linear temperature sensor Single temperature sensors Temperature perturbations caused by leak Vertical temperature profile measurements (including temperature measurements in piezometers) Temperatures

Linear temperature sensors Optical Distributed Sensing Systems Fiber optic temperature sensing: Spectral analysis of backscattered light Spatial resolution 1m Resolution ± 0,1 C Measurement distance - up to 30km with one fiber optic cable Optimal for installation on new damming constructions (dams, levees,.), during renovations and assuming the decades-long application

Problems with DFOTS application at existing structures COST OF APPLICATION Costly earthworks of cable installation Costly technology for short distances of measurements and/or particularly for temporally leakage or erosion problem monitoring (costly sensing head - DTS unit) SAFETY PROBLEMS OF THE STRUCTURE Earthworks affect the body or the foundation of the structure. Foundation structure must be rebuilt very carefully. In the case of high water level in the body of damming structure the risk of fiber optic cable installation can be to high to accept this monitoring solution application

Linear temperature sensors MPointS Driving Multi Points Sensor to use for passive or/and active quasi continuous thermal monitoring MPointS are mounted without an excavation by inserting successive sensors in a series, one after another without necessity of the earthworks. MPointS can be installed along the damming structure particularly at its downstream toe instead of fiber optic cable. Can be installed much deeper than fiber optis cabel Particularly useful for monitoring of existing dams and embankments. Much cheaper and easier for installation than fiber optics. Optimal for use for temporary monitoring (up to several years) of leakages and internal erosion processes in order to optimize decisions abour necessity of renovation and/or about its range.

Linear temperature sensors MPointS - installation

Passive and active thermal monitoring PASSIVE METHOD ACTIVE METHOD Natural temperatures measurements Heat emission measurements Schematic extent of the leak detection zone for spot measurements ACTIVE METHOD PASIVE METHOD

Active method laboratory test of heat distribution for different moisture values Temperatures [ºC] Heater Temperatures [ºC] Temperatures [ºC] Time [minutes] Time [minutes] Time [minutes]

Location of linear temperature sensors Earth dams and levees Temperature sensors Membran Temperature sensor Concrete dams Temperature sensors Temperature sensor Membran Canals Temperature sensors Membran Temperature sensors

Research in real scale confirmed that thermal monitoring is reliable and precise tool and allows for early detection of leakages and internal erosion Fiber optic located in downstream toe Fiber optic located below upstream membran LEAKAGE DETECTION OF ORDER OF 1 liter/minute (measured at upstream slope) RadzickI (2009), Beck et all. (2010, 2012), LEAKAGE DETECTION OF ORDER OF 0,2 liter/minute

2009 IjkDijk test

2009 IjkDijk test 2009/12/04 18:24 2009/12/05 00:24 2009/12/06 06:24 2009/12/06 11:24 Beck et all. (2010, 2012)

Models of passive thermal monitoring Radzicki (2012)

Examples of applications DIKE OF THE ORAISON CANAL

Examples of applications DIKE OF THE ORAISON CANAL Canal of Analyze direction

1-R 2 Examples of applications IRFTA MODEL application results for dike of the Oraison canal Damping of air temperature signal α pw Time of transition of air temperature signal η pw (days) (days) No significant seepage Damping of water temperature signal α wd Time of transition of water temperature signal η wd Safe seepage No seepage Radzicki and Bonelli (2009,2010)

Examples of applications DIKE OF CURBAN CANAL OF DURANCE RIVER 5 km of fiber optic Canal of

Examples of applications DIKE OF CURBAN CANAL OF DURANCE RIVER Courivaud et all. (2013)

Examples of applications DIKE OF CURBAN CANAL OF DURANCE RIVER 10 5 Thermal active measurements ΔT 0-5 Leakages High value of information Courivaud et all. (2013) 1000 2000 3000 4000 5000 m

Examples of applications RIGHT LEVEE OF RHINE RIVER 38 km of fiber optic Courivaud et all. (2014)

Quasi 3D thermal monitoring and displacements monitoring Vertical thermometric profiles Multi-point hydrolevelling instrument Linear thermal monitoring of water proof element Linear thermal monitoring in downstream toe Hydroprofile meter Radzicki (2014, 2015) Automatic inclinometers

Kozłowa Góra dam

Kozłowa Góra dam

Kozłowa Góra dam flood 2010 2010 Flood 2010

MCableS - Vertical temperature profiles of reservoi Kozłowa Góra dam Therm3Detect

Kozłowa Góra dam MCableS Measurements of vertical temperature profiles in the dam body in existing Elevation (AMSL) piezometres PASSIVE THERMAL METHOD Elevation (AMSL) Distance (m) (m) Therm3Detect Temperature ( C)

MPointS QUASI LINEAR PASSIVE temperature measurements along the dam in the downstream toe Elevation (AMSL) Kozłowa Góra dam PASSIVE THERMAL METHOD Distance (m) (m) Therm3Detect 35

Kozłowa Góra dam ACTIVE METHOD SPC5 120cm SPC5 170cm SPB5 120cm Different degree of saturation Saturated zone Therm3Detect SPB5 170cm Time (days)

Kozłowa Góra dam Therm3Detect

Intermediate results of research carried out by: K.Radzicki P.Opaliński S.Bonelli This scenario reproduce with a good accuracy the real temperature measurements carried out in the body and the foundation of dam Kozłowa Góra dam NUMERICAL MODELLING CORE DEGRADATION SCENARIO SCENARIO OF HIGHER PERMEABILITY ZONE IN FONDATION RELATIVELY GOOD STATE CONDITION SCENARIO (PERMEABILITY OF FONDATION AND BODY EQUAL ABOUT 1e-5 m/s) High value of information, low cost of the solution

The first levee in Poland instrumented in thermal monitoring system including linear thermal monitoring 2016 Leakage zones observed during the floods MPointS Quasi linear temperature measurements in downstream toe MPointS - Vertical temperature profile measurements in the piezometers

Example of methodology of levees state assessment Potential erosion zone indicated by one of geophysical methods, recommended installation of linear thermal monitoring instruments Linear thermal monitoring of urban area Geophysical investigations Geophysical investigations Location of geotechnical investigations indicated geophysical monitoring Radzicki (2013) by Location of geotechnical investigations indicated by linear thermal monitoring Additional geophysical investigation after visual inspection

KEY FEATURES OF THERMAL MONITORING METHOD MONITORING OF LEAKAGES AND INTERNAL EROSION PROCESSES IS CONTINOUS ALONG DAMMING CONSTRUCTION EARLY DETECTION OF LEAKAGES AND INTERNAL EROSION PROCESSES IT ALLOWS TO EVALUATE DYNAMIC OF THE PROCESSE AND SPATIAL DYSTRIBUTION OF LEAKAGES AND INTERNAL EROSION PROCESSES POSSIBILITY OF AUTOMATIC DETECTION OF LEAKAGE AND THE RISK OF EROSION APPLICATION RESULTS OF THERMAL MONITORING MINIMIZATION OF THE FAILURE PROBABILITY DUE TO THE DEVELOPMENT OF INTERNAL EROSION (PIPING ESPECIALLY) AND/OR LEAKAGE MINIMIZATION OF THE SCOPE AND COSTS OF RENOVATION THROUGH ACCURATE DIAGNOSIS AND RELIABLE ASSESMENT OF DYNAMIC AND SPATIAL DYSTRIBUTION OF LEAKAGES AND INTERNAL EROSION PROCESSES radzicki@hotmail.fr

Thank you for your attention Krzysztof Radzicki Ph.D Eng radzicki@hotmail.fr tel. +48 694 443 923