Geometry Induced Microparticle Separation in Passive Contraction Expansion Straight Channels

Similar documents
Postprint.

Differential inertial focusing of particles in curved low-aspect-ratio microchannels

Cruz, J., Hooshmand Zadeh, S., Wu, Z., Hjort, K. (2016) Inertial focusing of microparticles and its limitations. In: (pp. 1-6).

Microdevices for Continuous Sized Based Sorting by AC Dielectrophoresis

Particle concentration influences inertial focusing in Multiorifice Flow Fractionation microfluidic devices

[Supplementary Figures]

Particle Focusing in Microchannel with Multi-Parallel Channels or Porous Orifice

Jurnal Teknologi APPLICATION OF ELECTRICAL CAPACITANCE TOMOGRAPHY FOR DENSE CROSS- SECTIONAL PARTICLE MIGRATION IN A MICROCHANNEL.

Lecture 18: Microfluidic MEMS, Applications

Sheathless Hydrophoretic Particle Focusing in a Microchannel with Exponentially Increasing Obstacle Arrays

CONTINUOUS SIZE-BASED SEPARATION OF MICROPARTICLES IN STRAIGHT CHANNELS

Inertial Microfluidic Physics

Inertial Focusing of Particles in Curved Microchannels

Computational Analysis for Mixing of Fluids Flowing through Micro- Channels of Different Geometries

Experiments at the University of Minnesota (draft 2)

Table of Contents. Preface... xiii

Electrophoresis (EP)-modified inertial migration of particles in a straight channel with symmetric semicircle obstacle arrays

Supplementary Information

A Multifunctional Pipette

Single and collective fiber dynamics in micro-flows. Anke Lindner, PMMH-ESPCI, Paris, France

Quantitative characterization of the focusing process and dynamic behavior of differently sized microparticles in a spiral microchannel

Ultrasonic particle and cell separation and size sorting

Inertial microfluidics: mechanisms and applications

Inertial focusing in a straight channel with asymmetrical expansion-contraction cavity arrays using two secondary flows

Supplementary Methods

Lattice Boltzmann Simulation of One Particle Migrating in a Pulsating Flow in Microvessel

Supporting Information. Railing Cells along 3D Microelectrode Tracks for a. Continuous-Flow Dielectrophoretic Sorting

ENMA490 Capstone: Design of Microfluidics Mixer

Microfluidics 1 Basics, Laminar flow, shear and flow profiles

Multi-Physics Analysis of Microfluidic Devices with Hydrodynamic Focusing and Dielectrophoresis

Lateral Migration and Orientation of Elliptical Particles in Poiseuille Flows

Microfluidic single cell sorting and trapping using dual spiral channels

Pinched Flow Fractionation: Continuous Size Separation of Particles Utilizing a Laminar Flow Profile in a Pinched Microchannel

Figure 3: Problem 7. (a) 0.9 m (b) 1.8 m (c) 2.7 m (d) 3.6 m

CENG 501 Examination Problem: Estimation of Viscosity with a Falling - Cylinder Viscometer

The Lift Force on a Spherical Particle in Rectangular Pipe Flow. Houhui Yi

Supporting information for. Microfluidic Impedance Cytometer with Inertial Focusing and. Liquid Electrodes for High-Throughput Cell Counting and

Flow Focusing Droplet Generation Using Linear Vibration

Fluid Mechanics Theory I

Chapter -5(Section-1) Friction in Solids and Liquids

FLUID MECHANICS PROF. DR. METİN GÜNER COMPILER

by Connor Parrott A THESIS submitted to Oregon State University Honors College in partial fulfillment of the requirements for the degree of

Three-dimensional hydrodynamic focusing with a single sheath flow in a single-layer microfluidic device

Supplementary Information

Concentrated suspensions under flow in microfluidic channel and migration effect

Supplementary information for

Supplementary Material (ESI) for Journal of Analytical Atomic Spectrometry This journal is The Royal Society of Chemistry 2010

Supplementary Information for Microfluidic Magnetophoretic Separations of Immunomagnetically Labeled Rare Mammalian Cells

Modeling of Suspension Flow in Pipes and Rheometers

Particle removal in linear shear flow: model prediction and experimental validation

Single Curved Fiber Sedimentation Under Gravity. Xiaoying Rong, Dewei Qi Western Michigan University

MECHANICAL PROPERTIES OF FLUIDS:

SUPPLEMENTARY FIGURES

Inertial migration of a sphere in Poiseuille flow

UNIT II Real fluids. FMM / KRG / MECH / NPRCET Page 78. Laminar and turbulent flow

Contents. Microfluidics - Jens Ducrée Physics: Laminar and Turbulent Flow 1

A Review on Different Micromixers and its Micromixing within Microchannel

Enhanced size-dependent trapping of particles using microvortices

TOPICS. Density. Pressure. Variation of Pressure with Depth. Pressure Measurements. Buoyant Forces-Archimedes Principle

Supplementary Figure 1: Micromechanical cleavage of graphene on oxygen plasma treated Si/SiO2. Supplementary Figure 2: Comparison of hbn yield.

Spiral microchannel with rectangular and trapezoidal cross-sections for size based particle separation

Paper No. ICMM

Hydrodynamics of Diamond-Shaped Gradient Nanopillar Arrays for Effective. DNA Translocation into Nanochannels. (Supplementary information)

Fast Bonding of Substrates for the Formation of Microfluidic Channels at Room Temperature

Supporting Information. Technique for real-time measurements of endothelial permeability in a

Lattice Boltzmann Simulations of Pinched Flow Fractionation

MECHANICAL PROPERTIES OF FLUIDS

arxiv: v1 [physics.flu-dyn] 19 Oct 2018

ESS 5855 Surface Engineering for. MicroElectroMechanicalechanical Systems. Fall 2010

The Magnitude of Lift Forces Acting on Drops and Bubbles in Liquids Flowing Inside Microchannels

NUMERICAL INVESTIGATION OF THERMOCAPILLARY INDUCED MOTION OF A LIQUID SLUG IN A CAPILLARY TUBE

RAREFACTION EFFECT ON FLUID FLOW THROUGH MICROCHANNEL

Introduction to Micro/Nanofluidics. Date: 2015/03/13. Dr. Yi-Chung Tung. Outline

Chapter 9. Solids and Fluids. States of Matter. Solid. Liquid. Gas

CFD Analysis of Forced Convection Flow and Heat Transfer in Semi-Circular Cross-Sectioned Micro-Channel

Supporting Information: PDMS Nanocomposites for Heat Transfer Enhancement in. Microfluidic Platforms

Lab on a Chip PAPER. Size-based microfluidic multimodal microparticle sorter. Introduction. Xiao Wang and Ian Papautsky*

Direct Simulation of the Motion of Solid Particles in Couette and Poiseuille Flows of Viscoelastic Fluids

Micro-Flow in a bundle of micro-pillars. A. Keißner, Ch. Brücker

Forces Acting on Particle

Chapter 9. Solids and Fluids

Control of inertial microfluidics

Experimental mixing characterization of Newtonian fluids mixing in asymmetric T-micromixers

On the Design and Optimization of Micro-Fluidic Dielectrophoretic Devices: A Dynamic Simulation Study

Thin Wafer Handling Challenges and Emerging Solutions

Magnetic actuation of microparticles for mass transfer enhancement

Wafer Scale Homogeneous Bilayer Graphene Films by. Chemical Vapor Deposition

Programmable Magnetic Actuation of Biomolecule Carriers using NiFe Stepping Stones

Deformability-Selective Particle Entrainment and Separation in a Rectangular Microchannel Using Medium Viscoelasticity

arxiv: v1 [cond-mat.soft] 8 Jan 2019

Effect of the size and pressure on the modified viscosity of water in microchannels

10 - FLUID MECHANICS Page 1

Electrokinetically driven deterministic lateral displacement for particle separation in microfluidic devices

Methods. Casting Mold Fabrication. Channel Fabrication. Sample assembly

Physics 3 Summer 1990 Lab 7 - Hydrodynamics

Using Microfluidic Device to Study Rheological Properties of Heavy Oil

Section 16.1 Potential Difference and Electric Potential

Supplementary Methods

Supplementary Informations Spatial cooperativity in soft glassy flows

Supplementary Figure 1 a) Scheme of microfluidic device fabrication by photo and soft lithography,

Transcription:

Geometry Induced Microparticle Separation in Passive Contraction Expansion Straight Channels Mustafa Yilmaz, Meral Cengiz, Huseyin Kizil Dept. of Metallurgical and Materials Eng. Istanbul Technical University Istanbul, 34469 Turkey e-mail: kizilh@itu.edu.tr Arzu Ozbey, Levent Trabzon Dept. of Mechanical Eng. Istanbul Technical University Istanbul, 34437 Turkey A bstract Particle separation in passive micro fluidic channels has been investigated in straight channels with contracting and expanding geometry is studied. The angles in the entrance of contacting part of the channel are varied and the influence of the forces on the particle focusing is studied at various fluid flow rates. Single focusing position could be achieved for a certain flow rate and an angle of inclination at the entrance of a contracting part in the direction of flow. K ey w ords- microparticle; separation; w all effect; focusing. I. INTRODUCTION Microparticle separation techniques have attracted extensive attention for their importance in clinical diagnostics, treatment, and various biomedical applications. Most common separation techniques involve centrifugation and membrane based filtration on macro scale systems. Microfluidics based particle separation systems have advantages over these techniques due to small amounts of sample and reagent, less time consumption, lower cost and high throughput. In general, separation techniques could be categorized as passive and active with respect to any available applied external forces. Active separation systems require external forces such as ultrasound, magnetic field, and dielectric field for controlling the behavior of the particles suspended in fluid [1 2]. Passive separation techniques do not require external forces; the separation relies entirely on the hydrodynamic effects, which are mainly caused by channel geometry. However, most of the passive separation systems suffer from low throughput and filtration efficiency due to low channel Re numbers [1 2]. The first experiment about inertial forces was accomplished by Segre and Silberberg [3] in which particles migrate to a radial equilibrium position at the pipe radius of 0.62 from the axis of the pipe, which is known as Tubular Pinch Effect. Working with a wide range of Re numbers, Matas et al. [4] experimentally confirmed the tubular pinch effect and found that the equilibrium positions shift towards the wall with increasing Re. Kim et al. [5] observed that particles focused to a narrow band along the perimeter, which is about 0.2 D h (hydraulic diameter) in low Re number (Re < 20). On the other hand, Di Carlo et al. [6] investigated the inertial focusing in a straight microchannel and proved that uniformly distributed particles in rectangular channels migrate across the streamlines of four symmetric equilibrium positions at the centers of the sides and move closer to the walls as particle Re number increases. Lateral migration of particles mainly depends on the ratio of the particle diameter to the channel hydraulic diameter (a p /D h ). Inertial effects are significantly large and particle focusing occurs in short distances in a p /D h > 0.07 criterion. They also point out that the focusing positions that occur in the straight channels can be determined by the fold symmetry of the channel s cross section. In a rectangular channel the flow will have two focusing positions [7]. Di Carlo et al. [8] also studied the equilibrium positions of cells with comparing the expanding channel types. It was determined that the equilibrium positions moved closer to the channel centerline in rapid expanding channel while they were closer to the channel wall in the gradual expanding channel. Recently, Asgar et al. [9] discovered that the inertial focusing positions of particles in a straight microchannel also depend on the channel aspect ratio. They found that particles converge to an equilibrium in two focused streams along the longer sidewalls for both H/W > 1 and W/H > 1 (H: Height, W: Width) at the same channel Re number. Shear gradient induced lift force is linked to the flow velocity profile at the location of the particle. Due to its larger weight and size, the particle moves a little more slowly than the fluid and relative velocity is larger on the wall side, a pressure difference acts on the particle to push it towards to the wall. The second lift force where induced lift force is linked to the vicinity of the solid surface is called as wall effect. The relative velocity closed to the wall side of the particle is reduced by the presence of the wall, and the pressure on the wall side is larger than that on the centerline side. A lift force is exerted on the particle towards the channel center. In this study, straight microfluidic channels with contracting and expanding geometry are studied. The angles in the entrance of contacting part of the channel are varied and the influence of the forces on the particle focusing is measured at various fluid flow rates. 89

II. MICROCHANNEL DESIGN The angle of the entrance to contraction part was varied while other parameters were kept constant. Schematic view of the designed channel geometry is shown in Fig. 1, and dimensions are given in Table 1. TABLE 2. Flow rates and particle Reynolds numbers in expanding/ contracting part of channel Flow rate (µl/min) Re P (expansion part) Re P (contraction part) 105 0,38 1,49 120 0,44 1,70 140 0,51 1,99 160 0,58 2,27 180 0,65 2,55 Figure 1. Schematic view of designed channel geometry IV. RESULTS AND DıSCUSSıON III. METHODS A. Fabrication SU 8 3050 (MicroChem Corp.) was spun on the 4 inch Si wafer at 500 rpm for 10 s with 100 rpm/s acceleration and then 3000 rpm for 30 s with 300 rpm/s acceleration. A soft bake process was done at 95 C for 15 min. After lithography, SU 8 coated wafer was post baked at 65 C for 1 min. following at 95 C for 5 min, and developed. Then it was placed in a petri dish for PDMS casting. Vacuum oven was used for degassing the PDMS and kept at the curing temperature of 150 C for 2 hours. After curing, PDMS was peeled off the mold and placed in oxygen plasma furnace with a glass substrate side by side for the surface treatment to improve the adhesion between PDMS and glass, then both pieces were bonded together for the final construction of the microfluidic device. TABLE 1. Design parameters of the channel geometry Width I 100 µm Width II 40 µm Length 200 µm α 30,45,60,90 B. Characterization A mixture of 0.04 ml solution containing 1% of 9.9µm diameter green fluorescent particles and 70 ml DI water was prepared. Flow rates were determined with respect to the particle Re numbers (Re P ). It has been shown that particle inertial lift forces are dominant when Re p > 1, causing the particles to migrate laterally inside the channels [10]. Flow rates and particle Re numbers used in this study are given in Table 2. For obtaining a stable image from green fluorescent particles, exposure rate and color were adjusted with respect to red, green and blue. Exposure rates were varied between the values of 80 µs to 160 µs in which microchannel borders are not visible so that the particle images could easily be viewed. For obtaining an image over time, accumulation settings were set at 40 frames, meaning each image taken contains accumulated 40 frames. A. Focusing Positions Using the line profile option of the DP72 microscope camera software, the positions of the accumulated particle flows images were obtained. The line profile system depends on the RGB color value of the points along the chosen line. From the RGB values focusing width and position were determined. The obtained images showing the focusing positions of the micro channels are given in Fig. 2. It can be seen from the figure highly concentrated single focusing can be obtained at certain flow rates for angled designs (30-45 - 60 ) at the upper side of the channel for certain flow rates while this could not be possible for 90 degree design. B. Intensity Analysis The brightness of the color image can be obtained with using the line profile option of the microscope. By using color intensity values it can be determined whether a certain flow rate can produce a single focus or a dual focus positions. While the intensity values give the value of the brightness of the focusing, that value needs to be adjusted with respect to the width of the focus in order to normalize the intensity value. Single focusing could be categorized as high intensity over low width values. In other words, in order to define a single focusing position for a certain flow rate, its intensity/width value must be much higher than that of its second focusing position value. Furthermore, for the single focusing position determination at different flow rates intensity/width value is divided by the flow rate values to normalize the color intensity with respect to flow rate. The obtained results are shown in Fig. 3. Left side of each graph corresponds to expansion region of the channel while the right side corresponds to contraction part of the channel. From the graphs, for a certain Re P value whether a focusing position is single or double is seen. Mark x shows the single focusing positions. For 45 and 60 degree designs have single focusing for two different flow rates in the contraction part of the channel while 30 degree design has only one and 90 degree design has none. 90

a) b) c) d) Figure 2. Particle flow with different angle of entrance at contraction part a) 90 o b) 60 o c) 45 o d) 30 o V. CONCLUSIONS Single focusing position could be achieved for a certain flow rate and an angle of inclination at the entrance of a contracting part in the direction of flow. This result can be explained with the vortex forces prior to the contraction part and the wall effect at the proposed angle. Fig. 4 illustrates these forces affecting the particle in the channel. From this figure, the x component of the vortex force will be decreasing with decreasing angle. This force is in the direction of the flow causing an increase in the flow rate. But that effect will not have significant effect at low angle values causing no change in the flow rate. In 60, 45 and 30 channel designs there exists a wall induced inertial lift force which affects prior to the contracting part. This lift force is perpendicular to the angled wall so that its x and y components are not same for different angle values. It has lower x component in lower angled designs. The x component of this wall induced inertial lift force has a decelerating effect for the fluid and particle flow and the y component of this wall induced inertial lift force is the main driving force for obtaining the single focusing position. The x component of the wall induced lift force of 60 design is higher than that of 45 or 30 design, at which the fluid flow will be affected more and its flow rate will be lower than those designs. As a result, a single focus was obtained in even expansion part of the channel at certain flow rates for 60 design. 91

Figure 3. Normalized intensity vs. Particle Reynols number for channels with different angle of entrance at contraction part 92

Figure 4. Geometry effects on the focusing mechanism ACKNOWLEDGMENT This paper presents part of the work carried out under The Scientific and Technological Research Council of Turkey, TUBITAK. Their support is gratefully acknowledged. REFERENCES [1] T. Kulrattanarak, R.G.M van der Sman, C.G. Schroën, and R.M. Boom Classification and evaluation of microfluidic devices for continuous suspension fractionation Advances in Colloid and Interface Science 142, 2008, pp. 53 66. [2] N. Pamme Continuous flow separations in microfluidic devices Lab Chip, 2007, pp. 1644 1659. [3] G. Segre and A. Silberberg, Radial particle displacements in Poiseuille flow of suspensions, Nature (London) 189, 1961, pp. 209-210. [4] P. Matas, J. Morris, and E. Guazzelli, Inertial migration of rigid spherical particles in Poiseuille flow, J. Fluid Mech. 515, 2004, pp. 171-195. [5] Y. Kim and J. Yoo, The lateral migration of neutrally-buoyant spheres transported through square microchannels, J. Micromech. Microeng. 18, 2008, 065015. doi:10.1088/0960-1317/18/6/065015. [6] D. DiCarlo, D. Irimia, R.G. Tompkins, and M. Toner Continuous inertial focusing, ordering, and separation of particles in microchannels Proc. Natl. Acad. Sci. U.S.A, 104, 2007, pp. 18892-18897. [7] D.R. Gosselt and D. DiCarlo Particle focusing mechanisms in curving confined flows" Analytical Chemistry, 81, 2009, pp. 8459 8465. [8] A.J. Mach and D. DiCarlo Continuous scalable blood filtration device using inertial microfluidics Biotechnology and Bioengineering, 2010, pp. 302-311. [9] S.I. Rubinow and J.B. Keller, The transverse force on a spinning sphere moving in a viscous fluid, Journal of Fluid Mechanics, vol. 11, 1961, pp. 447 459. [10] J.S. Park and H.I. Jung, Multiorifice flow fractionation: Continuous size based separation of microspheres using a series of contraction/expansion microchannels, Analytical Chemistry, 81, 2009, pp. 8280 8288. 93