Physics Dept. PHY-503-SEMESTER 112 PROJECT. Measurement of Carbon Concentration in Bulk Hydrocarbon Samples

Similar documents
DETERMINATION OF THE HYDROGEN CONTENT OF OIL SAMPLES FROM NIGERIA USING AN Am-Be NEUTRON SOURCE.

TIIVISTELMÄRAPORTTI (SUMMARY REPORT)

TIIVISTELMÄRAPORTTI (SUMMARY REPORT)

This paper should be understood as an extended version of a talk given at the

Nuclear Reactions A Z. Radioactivity, Spontaneous Decay: Nuclear Reaction, Induced Process: x + X Y + y + Q Q > 0. Exothermic Endothermic

A Monte Carlo Simulation for Estimating of the Flux in a Novel Neutron Activation System using 252 Cf Source

Measurement of Hydraulic Conductivity, Porosity and Lithology by Neutron Activation Borehole Logging at high spatial resolution increments

Detection of explosives and fissile material based on neutron generators, survey of techniques and methods. M. Bruggeman

MC simulation of a PGNAA system for on-line cement analysis

6 Neutrons and Neutron Interactions

New Scintillators for the Border Monitoring Equipment

Response function measurements of an NE102A organic scintillator using an 241 Am-Be source

Introduction to Radiological Sciences Neutron Detectors. Theory of operation. Types of detectors Source calibration Survey for Dose

Measurements of liquid xenon s response to low-energy particle interactions

Measurement of Average Thermal Neutron Flux for PGNAA Setup

Activation Analysis. Characteristic decay mechanisms, α, β, γ Activity A reveals the abundance N:

An introduction to Neutron Resonance Densitometry (Short Summary)

Measurement of induced radioactivity in air and water for medical accelerators

Chapter 3: Neutron Activation and Isotope Analysis

Flux and neutron spectrum measurements in fast neutron irradiation experiments

CALIBRATION OF SCINTILLATION DETECTORS USING A DT GENERATOR Jarrod D. Edwards, Sara A. Pozzi, and John T. Mihalczo

Shielded Scintillator for Neutron Characterization

Pulsed Neutron Interrogation Test Assembly - PUNITA

HANAA* Humans Applying Neutron Activation Analysis Hassan Amany Noura Ahmed Ali

Total probability for reaction Yield

COMPARATIVE STUDY OF PIGE, PIXE AND NAA ANALYTICAL TECHNIQUES FOR THE DETERMINATION OF MINOR ELEMENTS IN STEELS

A Comparison between Channel Selections in Heavy Ion Reactions

EEE4106Z Radiation Interactions & Detection

Unit 2 Exam - Atomic Structure and Nuclear

Distinguishing fissions of 232 Th, 237 Np and 238 U with beta-delayed gamma rays

Background Reduction Using Collimators on a Portable HPGe Nuclide Identifier

POSITION SENSITIVE DETECTION OF CONCEALED SUBSTANCES EMPLOYING PULSED SLOW NEUTRONS

International Journal of Scientific & Engineering Research, Volume 5, Issue 3, March-2014 ISSN

Determination of the boron content in polyethylene samples using the reactor Orphée

Preparatory experiments for cold-neutron induced fission studies at IKI

Introduction to Ionizing Radiation

Neutron Detection. n interactions with matter n detection High/low energy n detectors

Using Neutron Generator with APT/NNA for Detection of Explosives

IdentiFINDER Digital Hand Held Spectrometer & Dose Rate Meter for Portable Applications

Chapter Four (Interaction of Radiation with Matter)

A. Aleksanyan, S. Amirkhanyan, H. Gulkanyan*, T. Kotanjyan, L. Poghosyan, V. Pogosov

SOURCES of RADIOACTIVITY

Neutron Sources Fall, 2017 Kyoung-Jae Chung Department of Nuclear Engineering Seoul National University

Principles and Applications of Neutron Based Inspection Techniques. Tsahi Gozani Rapiscan Laboratories 520Almanor Ave, Sunnyvale, CA

Measurements of Neutron Total and Capture Cross Sections at the TOF spectrometers of the Moscow Meson Factory

Design, Construction, Operation, and Simulation of a Radioactivity Assay Chamber

Neutronics Experiments for ITER at JAERI/FNS

Nuclear Cross-Section Measurements at the Manuel Lujan Jr. Neutron Scattering Center

DETECTORS. I. Charged Particle Detectors

Today, I will present the first of two lectures on neutron interactions.

Measurement of prompt fission γ-ray spectra in fast neutroninduced

Air Cargo Inspection using Pulsed Fast Neutron Analysis

(10%) (c) What other peaks can appear in the pulse-height spectrum if the detector were not small? Give a sketch and explain briefly.

4. The mass of a proton is approximately equal to the mass of A an alpha particle C a positron. B a beta particle D a neutron

Radioactivity III: Measurement of Half Life.

1.4 The Tools of the Trade!

Powerful Nanosecond Single- Shot Technique for Detection of Illicit Materials and Explosives

Initiation of nuclear reactions under laser irradiation of Au nanoparticles in the aqueous solution of Uranium salt. A.V. Simakin and G.A.

Dedicated Arrays: MEDEA GDR studies (E γ = MeV) Highly excited CN E*~ MeV, 4 T 8 MeV

Collimated LaBr 3 detector response function in radioactivity analysis of nuclear waste drums

Quality control of neutron-absorber materials for the nuclear fuel cycle, Principle of the JEN-3 neutron Backscattering gauge

DIGITAL PULSE SHAPE ANALYSIS WITH PHOSWICH DETECTORS TO SIMPLIFY COINCIDENCE MEASUREMENTS OF RADIOACTIVE XENON

STUDY ON THE ENERGY RESPONSE OF PLASTIC SCINTILLATION DETECTOR TO MEV NEUTRONS ABSTRACT

NJCTL.org 2015 AP Physics 2 Nuclear Physics

Photofission of 238-U Nuclei

SECTION A Quantum Physics and Atom Models

A Measurement of Monoenergetic Neutrons from 9 Be(p,n) 9 B

Total Neutron Scattering. Methane Confined in Aerogel Glass. Haiyang Yan

Figure 1. Decay Scheme for 60Co

NUCL 3000/5030 Laboratory 2 Fall 2013

Using Fast Neutrons to Detect Explosives and Illicit Materials

Isotopes: atoms with the same Z but different A s (number of neutrons varies)

RESULTS AND DISCUSSION ON EFFECT OF COLLIMATOR SIZE ON THE ATTENUATION OF GAMMA RAY IN PURE ELEMENTS

NEUTRON GENERATORS AND DAQ SYSTEMS FOR TAGGED NEUTRON TECHNOLOGY

Measurement of nuclear recoil responses of NaI(Tl) crystal for dark matter search

in2p , version 1-28 Nov 2008

In-situ element analysis from gamma-ray and neutron spectra using a pulsed-neutron source Maleka, Peane Peter

The 46g BGO bolometer

Bi β + Po Bismuth-214 is radioactive. It has a half-life of 20 minutes. (a) The nuclide notation for bismuth-214 is Bi.

Nuclear Fission. Q for 238 U + n 239 U is 4.??? MeV. E A for 239 U 6.6 MeV MeV neutrons are needed.

Regents review Nuclear Chemistry

Neutron Interactions Part I. Rebecca M. Howell, Ph.D. Radiation Physics Y2.5321

Neutron Transport Calculations Using Monte-Carlo Methods. Sean Lourette Fairport High School Advisor: Christian Stoeckl

Application of Neutron-capture to Elemental Analysis

MCNP Simulations of Fast Neutron Scattering by Various Elements and their Compounds in View of Elaboration of a Single Shot Inspection System


5 Atomic Physics. 1 of the isotope remains. 1 minute, 4. Atomic Physics. 1. Radioactivity 2. The nuclear atom

Instrumental Neutron Activation Analysis

Neutron Interactions with Matter

Nuclear Physics. AP Physics B

Neutron Shielding Properties Of Concrete With Boron And Boron Containing Mineral

Radioactivity. Lecture 6 Detectors and Instrumentation

CHAPTER 7 TEST REVIEW

Nuclear Physics and Nuclear Reactions

Nuclear reactions and nuclear ssion

SCANNING OF CARGO CONTAINERS BY GAMMA-RAY AND FAST NEUTRON RADIOGRAPHY

MAJOR NUCLEAR BURNING STAGES

NEUTRON TECHNOLOGIES (PAPER II)

Angular Distribution of Neutrons from. by Frank Genevese Physical Review Vol.76, # 9 (Nov 1, 1949) A paper on experiment Paper Club, 22, Feb, 2011

Investigation of Pygmy Dipole Resonance in neutron rich exotic nuclei

Transcription:

Physics Dept. PHY-503-SEMESTER 112 PROJECT Measurement of Carbon Concentration in Bulk Hydrocarbon Samples Prepared by: Hasan Mohammed Hasan ID: 201002200 Supervisor: Prof. A.A. Naqvi Coordinator: Prof. Khalil A. Ziq

TABLE OF COTENTS 1. Introduction.... 1 2. PGNAA Technique..........1 3. Experimental Set up.....3 4. Results and Discussion.... 5 4.1 Energy Calibration of LaCl3: Ce Detector....5 4.2 Prompt Gamma Analysis of Carbon in Different Samples 7 5. Conclusion... 9 6. References...... 10

Abstract In this experiment, PGNAA technique was used with LaCl 3 :Ce gamma-ray detector to measure carbon concentration in : Propanol (C 3 H 8 O), Porpanic-Acid (C 3 H 6 O 2 ), Butyl- Alkhol (CH 3 (CH 2 ) 3 OH and Formic-Acid (HCOOH) samples. Water and benzene samples were used for peak identification and energy calibration of the LaCl 3 :Ce gamma-ray detector based on PGNAA setup. It is found that, yield of prompt gamma ray increases linearly with increasing in the concentration of carbon in the sample, showing excellent performance of the LaCl 3 :Ce gamma-ray detector in detection of carbon in bulk sample using 14 MeV inelastic scattering.

1. Introduction Prompt gamma-ray neutron activation analysis (PGNAA) is ideally suitable for nondestructive in-situ measurements of elemental concentration of bulk samples [1]. Applications of prompt gamma-ray neutron activation analysis technique is increasing in various industrial, environmental, homeland security, medical discipline due to continuous development in gamma ray detection capability such as improved energy resolution and detection efficiency[2]. Experimental requirements differ from one application to another; each type of application requires specialized gamma-ray detectors, neutron source energy, intensity, etc. application involving detection of low energy prompt gamma-rays requires gamma detectors with excellent energy resolution while applications involving detection of elements with low neutron capture or scattering cross section requires intense neutron source [1]. Recently, lanthanide-halide LaBr 3 :Ce and LaCl 3 :Ce gamma-ray detectors are available in large crystal sizes and they exhibit improved energy resolution and faster light decay time compared to conventional NaI and BGO gamma-ray detectors [3]. In this work, PGNAA technique with LaCl 3 :Ce gammaray detector were used to measure carbon concentration in: Propanol (C 3 H 8 O), Porpanic- Acid (C 3 H 6 O 2 ), Butyl-Alkhol (CH 3 (CH 2 ) 3 OH and Formic-Acid (HCOOH) sample, concentration calibration for carbon was also obtained. Water and benzene samples were used for peak identification and energy calibration of the LaCl 3 :Ce gamma-ray detector based on PGNAA setup. 2. PGNAA Technique PGNAA was developed for detection of concealed explosives in airline luggage during the late 1980s and is now being investigated and tasted for new applications. These applications include detection of drugs in passenger luggage, detection of explosives in bottles, and detection of buried land mines and unexploded ordnance. For explosive, the PGNAA is based on the 10.8 MeV capture gamma ray from nitrogen, whose high density is uniquely characteristic of modern high explosives. In Neutron Activation Analysis (NAA), neutrons are used to bombard a simple, and then neutrons interact with atoms in the sample to create new radioactive isotopes. As these radioactive 1

nuclides decay, they emit gamma rays whose energies characteristic for each nuclide. By measuring the gamma rays released when these isotopes decay, it is possible to determine which elements are present and their concentration by comparison of intensities of these gamma rays. NAA technique is divided in two branches, with respect to a major experimental parameter; whether nuclear decay products (gamma rays) are measured during neutron irradiation (PGNAA), or at some time after irradiation (DGNAA) as shown in Figure 2.1. In the PGNAA technique, a material is irradiated with fast neutrons, some are moderated by the material in an external moderator. These neutrons interact with the material through neutron inelastic scattering (, ) which this experiment based on, or thermal neutron capture (, ) or both. Since we are going to detect carbon, Figure 2.2 shows prompt gamma rays energies due to inelastic scattering of neutrons from C, N and O elements. To sum up, in PGNAA technique, the method is to excite prompt gamma either by thermal capture of thermal neutrons or by inelastic scattering of fast neutrons which used for nuclei like C, O and N having very small thermal capture. Figure.2.1: Schematic diagram illustrates nuclear decay products, prompt and delayed gamma ray but there are some advantages in choosing the prompt gamma rays produced by thermal neutron capture for elemental analysis. The prompt gamma rays, due to thermal neutron 2

capture have generally higher energy as compared to those from neutron inelastic scattering. Accordingly, it is easier to detect higher energy thermal capture gamma rays. Prompt gamma rays neutron activation analysis (PGNAA) is non-destructive technique and is widely used for identification and quantification of elements in bulk gas, liquid, or solid samples. For detection of drugs, the use of capture gamma ray signals from both hydrogen and chlorine (from hydrochloride drug salt) have been investigated, and specific set of features based on these gamma ray signals selected for detection algorithm. The technique is ideally suited for determination of elements concentration such as carbon, boron, chlorine, cadmium [4]. Figure.2.2: Gamma ray decay scheme from inelastic scattering of neutrons from C, N and O 3

3. Experimental setup The response of the detector was measured for high energy prompt gamma rays using the 14 MeV neutron-based PGNAA setup shown in Fig. 3. [5]. The setup consisted of a 9.0 cm Φ x 14.0 cm cylindrical plastic container filled with the sample material and placed 7.0 cm in front of the water-cooled tritium target, at 0o angle with respect to the 14 MeV neutron beam. The gamma ray detector was placed at a center-to-center distance of 11.9 cm from the sample, at an angle of 90 degrees with respect to the 14 MeV neutron beam. Tungsten blocks were inserted between the tritium target beam line and the gamma ray detector to shield it from direct beam of 14 MeV neutrons. Furthermore, the detector was shielded from the 14 MeV neutron-induced gamma ray background by lead blocks inserted between the detector and the tungsten shield. Fig.3: Schematic of 14 MeV neutron-based setup used for measurement of H, C and O concentration in bulk samples. 4

Finally, a paraffin shield was built around the detector enclosing the lead and tungsten blocks, to shield it from room-scattered neutrons. The paraffin shield was prepared by mixing lithium carbonate and paraffin wax in equal weight proportions. Although the paraffin and lead shields were effective in shielding the detector against scattered neutrons and background gamma rays, the gamma ray peaks due to the inelastic scattering of 14 MeV neutrons from lead were quite pronounced in the gamma ray detector pulse height spectrum. A pulsed beam of 14 MeV neutrons was produced via the T(d,n) reaction using a pulsed deuteron beam with 200 ns width and a frequency of 31 khz. The typical pulsed beam current of the accelerator was 60 µa dc beam current. As shown in Fig. 3, the fast neutron flux from the tritium target was monitored using a 7.6 cm Φ x 7.6 cm cylindrical NE213 fast neutron detector, placed at a distance of 1.8 m from the target and at a backward angle of 130 degrees with respect to the beam axis on the opposite side of the LaBr3:Ce detector gamma-ray detector. The 14.8 MeV neutron flux was measured to be 106 n/cm2/s. The prompt gamma-rays spectrum of the LaCl 3 :Ce was recorded for a preset time. 4. Results and Discussion 4.1 Energy Calibration of LaCl 3 : Ce Detector Detectors with its components do not give us a direct reading for energy versus intensity, rather it is a relationship between intensity and channel number so that, before any measurement we need to calibrate our detector and peak identification. For this purpose two samples, water and benzene, were used. Also because our main goal is to detect carbon and measure its concentration, it is useful to determine in advance the position of the carbon and oxygen peaks. Figure 4 shows the Pulse height spectrum of the LaCl: Ce detector for water and Benzene samples. 5

18000 N-Water-v50 Prompt Gamma Ray Exp. Yield 16000 14000 12000 10000 C-peak DE-peak SE-peak N-Benzene-v50 O-peak 8000 6000 210 230 250 270 290 310 330 Prompt Gamma Ray Energy (MeV) Fig. 4: Pulse height spectrum of the LaCl: Ce detector for water and Benzene. For water, Oxygen s concentration (H 2 O) is very high comparing to hydrogen and it is zero for carbon. In contrast, for benzene (C 6 H 6 ), Oxygen s concentration is zero but it is high for carbon. Therefore, water can be used to determine the position of oxygen and benzene for carbon, the spectrum of water, in the figure above, shows the three peaks: oxygen, single escape and double escape peaks, respectively from right to left. Whereas the benzene spectrum shows one sharp peak refers to carbon and two small peaks fitted with the oxygen and SE peaks which come from the atmosphere since, there is no oxygen in the benzene sample. The table below shows the Prompt Gamma ray energy corresponding to each channel number. 6

Peak Ch# Energy (MeV) C 228 4.44 DE 264 5.1 SE 290 5.62 O 317 6.13 Table 4: Prompt Gamma ray energy corresponding to each channel number. 7 Prompt Gamma ray Energy (MeV) 6 5 4 3 2 1 0 y = 0.019x + 0.0938 0 50 100 150 200 250 300 350 Channel number Fig 4.1: Energy calibration curve of the LaCl: Ce detector Figure 4.1 shows the energy calibration graph for LaCl 3 :Ce gamma-ray detector. The calibration equation of the detector is given by Eγ(MeV) = 0.019 X + 0.0938, where X is the channel number. 7

4.2 Prompt Gamma Analysis of Carbon in Propanol, Propanic-Acid, Butyl-Alkhol, Formic-Acid Samples. Detecting carbon was obtained in four different samples; Propanol (C 3 H 8 O), Porpanic-Acid (C 3 H 6 O 2 ), Butyl-Alkhol (CH 3 (CH 2 ) 3 OH and Formic-Acid (HCOOH). Each one has a different concentration of carbon which can be used for calibration. Table 5 shows the Elemental composition of Propanol, Propanic-Acid, Butyl-Alkhol, Formic- Acid which reveals the different concentration of carbon. Compounds Chemical Formula C (wt%) O (wt%) H (wt%) Propanol C 3 H 8 O 60 26 13.3 Propanic-Acid C 3 H 6 O 2 48.6 43.2 8.1 Butyl-Alkhol CH 3 (CH 2 ) 3 OH 64.8 21.6 13.5 Formic-Acid HCOOH 26 69.5 4.3 Table 5: Elemental composition of Propanol, Propanic-Acid, Butyl-Alkhol, Formic-Acid Using LaCl3:Ce gamma-ray detector, the obtained spectrum for all samples is shown in Figure 5.1. It reveals the two original peaks correspond to carbon (4.44 MeV) and oxygen (6.13 MeV) with different intensity depending on the concentration of element in each sample. The other two peaks (5.6, 5.1 MeV) correspond to the single and double escape. Regarding the hydrogen peak (2.2 MeV), it is not appears in the spectrum because it is in the low energy range. In this work we are going to investigate the concentration of carbon versus the Prompt Gamma Ray Exp. Yield. Figure 5.2 shows the Pulse height spectrum of the LaCl: Ce detector for carbon peak in all samples. It is reveals that the higher concentration of carbon in the sample gives the higher prompt gamma ray experiment yield. 8

Prompt Gamma Ray Exp. Yield 17500 15500 13500 11500 9500 C-peak DE-peak SE-peak O-peak N-Propanol-v50 P-acid butyl-alkohl F-acid 7500 4 4.4 4.8 5.2 5.6 6 6.4 Gamma Ray Energy (MeV) Fig5.1: Pulse height spectrum of the LaCl: Ce detector for O, C, SE and DE peaks in samples Prompt Gamma Ray Exp. Yield 18000 17500 17000 16500 16000 15500 15000 14500 14000 N-Propanol-v50 P-acid butyl-alkohl F-acid 13500 13000 4 4.2 4.4 4.6 4.8 Gamma Ray Energy (MeV) Fig5.2: : Pulse height spectrum of the LaCl: Ce detector for carbon peak in all samples 9

Figure 5.3 shows the yield of 44.4 MeV prompt Gamma Ray of carbon from four samples plotted as a function of carbon concentration. It reveals that yield of prompt gamma ray increases linearly with increase in the concentration of carbon in the sample 17400 Prompt Gamma Ray Exp. Yield 17200 17000 16800 16600 16400 16200 16000 y = 26.541x + 15434 0 10 20 30 40 50 60 70 Carbon Concentration (wt.%) Fig5.3: Yield of 44.4 MeV prompt Gamma Ray of carbon from four samples 5. Conclusion In this experiment, PGNAA technique was used with LaCl 3 :Ce gamma-ray detector to measure carbon concentration in : Propanol (C 3 H 8 O), Porpanic-Acid (C 3 H 6 O 2 ), Butyl- Alkhol (CH 3 (CH 2 ) 3 OH and Formic-Acid (HCOOH) samples. Water and benzene samples were used for peak identification and energy calibration of the LaCl 3 :Ce gamma-ray detector based on PGNAA setup. It is found that, yield of prompt gamma ray increases linearly with increasing in the concentration of carbon in the sample, showing excellent performance of the LaCl 3 :Ce gamma-ray detector in detection of carbon in bulk sample using 14 MeV inelastic scattering. Due to the energy peak of chlorine (Cl) 6.11 MeV, which is close to oxygen s peak 6.3 MeV, makes the measurements of oxygen s concentration not accurate result in the interference of the two peaks. 10

6. References [1] A.A.Naqvi., Z.Kalakada,, M.S. Al-Anzi,, M. Raashid,, Khateeb-ur-Rehman,, M. Maslehuddin,, & M.A. Garwan, (2012). Low energy prompt gamma-ray test of large volume bgo detector. Applied Radiation and Isotopes, 70, 222-226. [2] A.A. Naqvi., M.S.Al-Anezi,, ZameerKalakada,, FarisA.AlMatouq,, M.Maslehuddin,, M.A.Gondal,, A.A. Isab,, & Khateeb-ur-Rehman, (2012). Response testsofalacl3:ce scintillationdetectorwithlowenergyprompt gamma raysfromboronandcadmium. Applied Radiation and Isotopes, 70, 882-887. [3] Naqvi A. A., M. Maslehuddin, M. A. Garwan, M. M. Nagadi, O.S. B. Al-Amoudi, M. Raashid, and Khateeb-ur-Rehman, "Effect of Silica Fume Addition on the PGNAA Measurement of Chlorine in Concrete." Appl. Radiat. Isot., Vol. 68(2010),pp.412-417. [4] M.S. Al-Anzi, thesis (2012), Performance of Lanthanide-Halide Scintillation Detectors in Prompt Gamma Analysis. [5] Naqvi, A. A., Fares A. Al-Matouq1,, F.Z. Khiari,, A. A. Isab,, Khateeb-ur-Rehman,, & M. Raashid, (n.d.). Prompt gamma tests of labr3:ce and bgo detectors for detection of hydrogen, carbon and oxygen in bulk samples. 11