Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Similar documents
Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

LM-79 Report TEST REPORT NO.M037D

LM-79 Report TEST REPORT NO. L523A

NVLAP LAB CODE LM Test Report. For REMPHOS TECHNOLOGIES LLC. (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA.

LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl350u1

NVLAP LAB CODE LM Test Report. For AOK LED LIGHT COMPANY LIMITED. (Brand Name: AOK)

NVLAP LAB CODE LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl5s50u1

NVLAP LAB CODE LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl4s50u1

NVLAP LAB CODE LM Test Report. For AOK LED LIGHT COMPANY LIMITED. (Brand Name: AOK)

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006

Photometric Test Report

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006

Cat# LED High Bay

NVLAP LAB CODE LM Test Report. For LED PANEL LIGHTING CO.,LTD. (Brand Name: N/A)

ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION

NVLAP LAB CODE LM Test Report. For. Shenzhen Guanke Technologies Co. Ltd. (Brand Name: )

NVLAP LAB CODE LM Test Report. For SIMKAR CORPORATION. (Brand Name: ) LED Lamp. Model name(s): SALXS350U1. Model differences: N/A

NVLAP LAB CODE LM Test Report. For SIMKAR CORPORATION. (Brand Name: ) LED Lamp. Model name(s): SALXS450U1. Model differences: N/A

Photometric Test Report

ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION

Beachside Lighting 905 Kalanianaole Hwy # 29A Kailua, HI

NVLAP LAB CODE LM Test Report. For. LED Wav es,inc. (Brand Name: LED Wav es)

Checked X.CAO

IES LM MEASUREMENT AND TEST REPORT For. IGT LIGHTING INC Lincoln St. Suite B, Riverside, CA Test Model: IGTFL

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD

Checked X.CAO

ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION

LED Entryway Light RoHS

1 General 1.1 Product Information Manufacturer Maxlite.Inc Page 2 of 17 Manufacturer Address 12 York Ave West Caldwell, NJ Brand Name Luminaire

Beachside Lighting 905 Kalanianaole Hwy # 29A Kailua, HI

LM Test Report. For. Beyond LED Technology. (Brand Name: Beyond LED) 2725 Mountain Industrial Blvd. Suite A-1 Tucker, GA 30084

NVLAP LAB CODE LM Test Report. For IGT LIGHTING INC. (Brand Name: IG T ) 3755 Lincoln St. Suite B, Riverside, CA 92503

Wet Locations Use 71400A 120 W PF V 2.9A 93% 144 pcs. Philips 130 LM/W 5000K Hrs. 5 Years. 24-1/4 Lbs 665*530*120 1 PCS

March 26, Title: TEMPO 21 Report. Prepared for: Sviazinvest, OJSC. Prepared by: Cree Durham Technology Center (DTC) Ticket Number: T

IES LM MEASUREMENT AND TEST REPORT For

Transcription:

NVLAP Lab Code 500089-0 Report Number: Model: Date: RESTL-2014-0031 BXSPWA02MC-US 01/28/2014 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Bernard Krauska Cree, Inc 9201 Washington Avenue Racine, WI 53406 Prepared By: Approved By: Linjie Li, Photometric Test Techniciann Steven Bowers, Photometric Test Engineer C r e e, I n c 9 2 0 1 W a s h i n g t o n A v e n u e R a c i n e, W I 5 3 4 0 6 Page 1 of 12 This report contains data that are not covered by the NVLAP accreditation.

NVLAP Lab Code 500089-0 Product Information Manufacturer Model Number (SKU) Serial Number LED Type Cree BXSPWA02MC-US PL03030-001 MDA Product Description Cast gray painted metal housing. One circuit board with four LEDs and white plastic trim plate. One clear plastic non-integral optic below each LED. Driver Information (Where Applicable) Cree LEM00004X0001A0 Length 9.0 Width Height 12.0 4.0 Sample The following sample was submitted for evaluation C r e e, I n c 9 2 0 1 W a s h i n g t o n A v e n u e R a c i n e, W I 5 3 4 0 6 Page 2 of 12

NVLAP Lab Code 500089-0 Key Photometric Data Sphere Output Goniophotometer Luminous Flux 4129 4127.6 lm Efficacy 96.40 96.12 lm/w Correlated Color Temperature (CCT) 5427 K Color Rendering Index (CRI) 72 R 9-16 Duv 0.0036 S/P Ratio* 1.84 Sphere Goniophotometer Electrical Measurements 120V 277V 120V 277V Input Wattage 42.83 42.30 42.94 42.42 W Input Current 0.36 0.17 0.36 0.17 A Input Voltage 120.08 277.10 120.05 277.07 V Power Factor 0.993 0.915 0.993 0.916 Off-State Power 0 0 0 0 W Total Harmonic Distortion (Voltage) 0.12 0.15 0.14 0.08 % Total Harmonic Distortion (Amperage) 5.79 16.12 5.64 14.85 % Note: All photometric measurements taken at 120VAC. Luminous Intensity Distribution Goniophotometer Max Candela 3533.6 Cd Angle of Max Candela (Horizontal) 60 Angle of Max Candela (Vertical) 60 Key Test Parameters Sphere Output Goniophotometer Stabilization Time 89 83 min Total Operating Time (Stabilization + Test) 94 103 min Ambient Temperature 25.3 24.6 C C r e e, I n c 9 2 0 1 W a s h i n g t o n A v e n u e R a c i n e, W I 5 3 4 0 6 Page 3 of 12

NVLAP Lab Code 500089-0 Chromaticity Coordinates ** x y u v u v Duv 0.3342 0.3496 0.2048 0.3214 0.2048 0.4821 0.0036 Ra R1 R2 R3 R4 72 71 75 77 74 Color Rendering Index Details ** R5 R6 R7 R8 R9 R10 R11 R12 R13 R14 73 67 78 62-16 40 74 48 71 87 Chromaticity Diagram ** C r e e, I n c 9 2 0 1 W a s h i n g t o n A v e n u e R a c i n e, W I 5 3 4 0 6 Page 4 of 12

Spectral Distribution ** NVLAP Lab Code 500089-0 λ(nm) W/nm λ(nm) W/nm λ(nm) W/nm 360 0.000153 530 0.063173 700 0.007833 370 0.000102 540 0.066807 710 0.005979 380 0.000044 550 0.067926 720 0.004534 390 0.000008 560 0.067919 730 0.003431 400 0.000495 570 0.066738 740 0.002564 410 0.003876 580 0.064140 750 0.001927 420 0.019301 590 0.060784 760 0.001436 430 0.053801 600 0.056283 770 0.001092 440 0.106848 610 0.051083 780 0.000805 450 0.083117 620 0.045109 790 0.000635 460 0.036163 630 0.038952 800 0.000439 470 0.017395 640 0.032685 810 0.000315 480 0.012590 650 0.026921 820 0.000212 490 0.016542 660 0.021726 830 0.000114 500 0.028680 670 0.017044 510 0.043657 680 0.013290 520 0.055854 690 0.010273 Dominant Wavelength ** 557 nm Peak Wavelength ** 443 nm 0.12 Spectral Power Distribution (W/nm) ** 0.1 Radiant Flux (W) 0.08 0.06 0.04 0.02 0 Wavelength (nm) C r e e, I n c 9 2 0 1 W a s h i n g t o n A v e n u e R a c i n e, W I 5 3 4 0 6 Page 5 of 12

Zonal Lumen Summary NVLAP Lab Code 500089-0 Zone Lumens % of Total Zone Lumens % of Total 0-5 17.1 0.4% 90-95 0 0% 5-10 55.9 1.4% 95-100 0 0% 10-15 102.2 2.5% 100-105 0 0% 15-20 153.6 3.7% 105-110 0 0% 20-25 203.6 4.9% 110-115 0 0% 25-30 244.7 5.9% 115-120 0 0% 30-35 276.9 6.7% 120-125 0 0% 35-40 296.6 7.2% 125-130 0 0% 40-45 349.1 8.5% 130-135 0 0% 45-50 460.9 11.2% 135-140 0 0% 50-55 531.0 12.9% 140-145 0 0% 55-60 475.8 11.5% 145-150 0 0% 60-65 404.0 9.8% 150-155 0 0% 65-70 278.5 6.7% 155-160 0 0% 70-75 168.4 4.1% 160-165 0 0% 75-80 75.4 1.8% 165-170 0 0% 80-85 27.7 0.7% 170-175 0 0% 85-90 6.2 0.2% 175-180 0 0% Total 4127.6 lm 100% C r e e, I n c 9 2 0 1 W a s h i n g t o n A v e n u e R a c i n e, W I 5 3 4 0 6 Page 6 of 12

NVLAP Lab Code 500089-0 Candela Plot Illuminance Plot Roadway Utilization Roadway Summary Cutoff Classification Distribution Downward Street Side Downward House Side Downward Total Upward Street Side Upward House Side Upward Total Total Lumens Lumens % Lamp FULL CUTOFF TYPE II, SHORT 3,123.0 75.7% 1,004.8 24.3% 4,127.8 100% 0 0% 0 0% 0 0% 4,127.8 100% C r e e, I n c 9 2 0 1 W a s h i n g t o n A v e n u e R a c i n e, W I 5 3 4 0 6 Page 7 of 12

NVLAP Lab Code 500089-0 Luminaire Classification System C r e e, I n c 9 2 0 1 W a s h i n g t o n A v e n u e R a c i n e, W I 5 3 4 0 6 Page 8 of 12

Candela Tabulations NVLAP Lab Code 500089-0 0 5 15 25 35 45 55 60 62.5 65 67.5 70 72.5 75 77.5 80 82.5 85 87.5 90 95 105 115 125 135 145 155 165 175 180 0 684 684 684 684 684 684 684 684 684 684 684 684 684 684 684 684 684 684 684 684 684 684 684 684 684 684 684 684 684 684 2.5 772 776 772 770 762 744 728 720 716 712 712 710 707 704 701 699 696 694 692 689 684 673 659 656 653 655 654 647 646 646 5 882 886 883 878 864 836 805 790 781 773 767 762 754 747 740 733 725 718 712 706 693 672 651 644 639 641 639 632 631 631 7.5 968 971 972 973 963 937 900 881 869 856 848 839 827 815 802 790 777 764 751 739 714 676 649 640 633 633 630 623 622 622 10 1039 1040 1051 1059 1052 1029 996 974 958 943 931 919 904 889 874 858 840 821 802 783 744 686 650 638 629 630 628 622 620 621 12.5 1086 1087 1100 1126 1128 1110 1086 1065 1048 1031 1015 999 980 960 941 922 900 878 853 829 777 699 657 644 637 641 641 634 634 634 15 1126 1127 1140 1165 1180 1179 1178 1168 1150 1132 1110 1086 1057 1028 1002 976 950 923 894 866 806 719 674 657 646 648 647 641 640 641 17.5 1168 1171 1191 1215 1232 1250 1269 1268 1254 1240 1214 1188 1148 1108 1067 1026 992 957 924 892 832 750 702 664 640 644 644 635 633 633 20 1220 1223 1249 1276 1286 1303 1318 1321 1312 1303 1279 1255 1208 1162 1111 1061 1020 978 944 909 854 790 734 665 628 627 630 625 621 621 22.5 1280 1284 1321 1341 1332 1331 1317 1316 1303 1291 1263 1236 1188 1140 1090 1041 1008 974 949 924 881 833 748 663 616 602 616 612 610 611 25 1317 1328 1398 1381 1349 1331 1284 1272 1261 1250 1226 1201 1156 1110 1063 1016 994 973 960 947 918 862 742 658 602 579 596 602 602 603 27.5 1347 1357 1419 1375 1341 1313 1249 1228 1218 1209 1187 1166 1127 1088 1044 1000 994 987 981 975 945 867 728 648 592 563 574 588 587 586 30 1375 1384 1408 1337 1323 1291 1239 1202 1192 1181 1164 1148 1113 1078 1036 995 990 985 982 978 943 855 716 641 585 561 559 580 574 573 32.5 1399 1398 1394 1311 1302 1262 1236 1190 1176 1161 1147 1134 1103 1072 1027 982 967 953 952 952 924 838 712 636 596 580 548 548 530 522 35 1401 1399 1368 1294 1300 1241 1223 1183 1163 1142 1133 1124 1095 1066 1016 966 940 914 917 919 900 829 708 640 626 534 448 434 422 416 37.5 1349 1354 1329 1270 1293 1236 1192 1173 1151 1130 1123 1117 1092 1068 1014 960 921 883 891 899 888 823 708 662 555 417 357 348 345 341 40 1577 1525 1409 1253 1284 1242 1168 1158 1142 1125 1121 1116 1097 1078 1044 1010 971 932 954 977 971 804 699 609 424 344 305 290 284 279 42.5 1962 1938 1800 1588 1314 1280 1214 1176 1163 1150 1157 1164 1183 1202 1197 1191 1136 1081 1089 1098 1069 763 656 482 352 296 258 235 226 221 45 2003 2015 2008 1853 1705 1366 1316 1257 1265 1272 1331 1390 1431 1472 1446 1420 1335 1250 1216 1182 1068 709 570 379 304 250 212 188 174 169 47.5 1932 1966 2038 2148 1981 1880 1928 1888 1860 1832 1835 1839 1808 1776 1712 1648 1542 1437 1341 1245 1003 644 473 329 261 208 172 149 137 133 50 1444 1534 1831 2234 2557 2531 2887 2967 2878 2788 2624 2460 2284 2108 1978 1848 1687 1526 1382 1238 915 584 393 283 220 169 140 123 114 113 52.5 808 880 1173 1781 2628 2976 3278 3268 3281 3294 3059 2824 2590 2356 2188 2020 1822 1624 1436 1248 891 556 348 241 184 140 120 111 101 101 55 323 345 521 914 1646 2794 3399 3182 3195 3209 2968 2727 2517 2308 2190 2072 1913 1755 1560 1366 1007 620 378 237 167 126 110 100 94 94 57.5 250 255 292 599 1101 2212 3346 3333 3245 3157 2959 2761 2621 2481 2390 2300 2144 1988 1783 1579 1225 674 390 235 159 124 106 94 91 93 60 204 207 231 337 852 1614 3252 3534 3406 3277 2994 2710 2587 2464 2382 2300 2132 1964 1748 1533 1341 695 351 196 136 118 104 94 92 97 62.5 172 173 184 250 529 1189 2846 3332 3255 3178 2869 2561 2417 2272 2186 2101 1921 1740 1547 1354 1184 564 243 151 124 118 110 98 92 95 65 123 125 144 193 291 762 2208 2902 2871 2839 2490 2141 2024 1907 1853 1799 1671 1543 1358 1172 918 351 181 131 127 139 137 123 105 106 67.5 82 83 99 144 208 423 1616 2190 2206 2221 1951 1681 1652 1622 1592 1561 1448 1335 1137 940 669 242 144 130 157 185 189 169 144 141 70 67 67 68 96 146 207 1111 1596 1643 1690 1522 1354 1350 1346 1304 1262 1158 1054 888 722 502 179 121 153 201 228 216 181 151 145 72.5 72 70 62 67 99 147 696 1177 1200 1222 1117 1011 1012 1013 992 970 900 830 700 571 375 121 112 179 223 196 140 102 87 83 75 60 59 56 55 68 110 391 785 778 770 728 686 687 688 653 618 568 518 465 412 261 89 120 198 151 88 64 54 48 47 77.5 43 42 38 38 50 91 227 456 435 415 402 388 388 387 371 354 322 290 274 258 170 79 145 132 64 42 40 41 36 34 80 33 31 28 25 36 76 118 209 193 178 186 193 208 223 227 232 207 183 165 147 105 82 130 58 30 29 31 29 24 22 82.5 18 17 18 17 24 55 63 88 87 85 99 113 127 141 147 153 135 118 99 80 65 92 68 25 19 18 18 15 12 11 85 9 8 9 9 12 32 37 39 40 42 52 63 73 83 87 92 81 70 56 41 38 68 22 10 7 5 3 1 1 1 87.5 2 2 3 3 5 15 18 16 17 17 23 29 34 40 43 46 40 34 25 16 18 21 4 1 0 0 0 0 0 0 90 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 C r e e, I n c 9 2 0 1 W a s h i n g t o n A v e n u e R a c i n e, W I 5 3 4 0 6 Page 9 of 12

Candela Tabulations (Continued) NVLAP Lab Code 500089-0 0 5 15 25 35 45 55 60 62.5 65 67.5 70 72.5 75 77.5 80 82.5 85 87.5 90 95 105 115 125 135 145 155 165 175 180 92.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 95 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 97.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 100 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 102.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 105 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 107.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 110 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 112.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 115 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 117.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 120 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 122.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 125 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 127.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 130 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 132.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 135 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 137.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 140 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 142.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 145 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 147.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 150 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 152.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 155 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 157.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 160 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 162.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 165 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 167.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 170 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 172.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 175 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 177.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 180 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 C r e e, I n c 9 2 0 1 W a s h i n g t o n A v e n u e R a c i n e, W I 5 3 4 0 6 Page 10 of 12

NVLAP Lab Code 500089-0 Integrating Sphere Equipment List Description Manufacturer Model Serial Number 2M Sphere Everfine 2M 1004156T CCD Array Spectrometer Labsphere MC-9801 98010360 Programmable AC Source Adaptive FC200 2280220 Power Analyzer Chroma 66202 66202 0005018 Goniophotometer Equipment List Description Manufacturer Model Serial Number AC Power Source Chroma 61602 616020002300 Type C Goniophotometer LSI / UL 6440T 6440PN2028 Spectroradiometer Gooch & Housego 770VIS/NIR 12415189 Power Meter Yokogawa WT210 91M945458 Test Methods Used: Title ANSI C82.77:2002 CIE Pub. 13.3:1995 CIE Pub. 15:2004 IES LM-58:1994 IES LM-65:2001 IES LM-79:2008 Description Harmonic Emission Limits- Related Power Quality Reqt s for Lighting Equipment Method of Measuring and Specifying Color Rendering of Light Sources Colorimetry Spectroradiometric Measurements Single-Ended Compact Fluorescent Lamps Life Test Performance Electrical and Photometric Measurements of Solid-State Lighting Products Reference Standard Used: Equipment 2m Sphere Type C Goniophotometer and Spectrometer Description Tungsten Halogen Omni-Directional 75W Calibration Lamp, Serial Number F119 Tungsten Halogen Omni-Directional 500W Calibration Lamp, Serial Numbers 13C069. 13C070, 13C071. For color calibration of spectrometer, 13C074. C r e e, I n c 9 2 0 1 W a s h i n g t o n A v e n u e R a c i n e, W I 5 3 4 0 6 Page 11 of 12

NVLAP Lab Code 500089-0 Disclaimers: This report must not be used by the customer to claim product certification, approval or endorsement by NVLAP, NIST or any agency of the federal government. The results contained in this report pertain only to the tested sample. This report shall not be reproduced, except in full, without written approval of the CESTL. Items marked with a single asterisk are not covered by the NVLAP accreditation. In the event that the recorded temperature is outside of 25 ± 1 C, this is considered a non-standard condition. ** In the event that testing is subcontracted, test results in this report marked with the symbol **, or noted as Sphere or Integrating Sphere, were performed by the subcontracted laboratory identified in the footer on the first page of this report. Subcontracted testing is strictly integrating sphere based. All other tests are performed using a Type C goniophotometer. The integrating sphere information in the equipment list, report items marked with **, or results specifically identified as Sphere or Integrating Sphere, are the actual equipment used, and test results produced, by the subcontracted laboratory when subcontracting is indicated on the cover page. Additional Comments: The photos below are intended to show the orientation and fixturing/set-up of the units under test. These are critical to understanding the results of the test given the sensitivity of many products and measurement systems to orientation and set-up considerations, and also for reproducing the conditions of the test. Goniophotometer Integrating Sphere C r e e, I n c 9 2 0 1 W a s h i n g t o n A v e n u e R a c i n e, W I 5 3 4 0 6 Page 12 of 12