Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Similar documents
Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

LM-79 Report TEST REPORT NO.M037D

LM-79 Report TEST REPORT NO. L523A

LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl350u1

NVLAP LAB CODE LM Test Report. For REMPHOS TECHNOLOGIES LLC. (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA.

NVLAP LAB CODE LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl5s50u1

NVLAP LAB CODE LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl4s50u1

NVLAP LAB CODE LM Test Report. For AOK LED LIGHT COMPANY LIMITED. (Brand Name: AOK)

Beachside Lighting 905 Kalanianaole Hwy # 29A Kailua, HI

Beachside Lighting 905 Kalanianaole Hwy # 29A Kailua, HI

NVLAP LAB CODE LM Test Report. For AOK LED LIGHT COMPANY LIMITED. (Brand Name: AOK)

NVLAP LAB CODE LM Test Report. For LED PANEL LIGHTING CO.,LTD. (Brand Name: N/A)

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006

March 26, Title: TEMPO 21 Report. Prepared for: Sviazinvest, OJSC. Prepared by: Cree Durham Technology Center (DTC) Ticket Number: T

NVLAP LAB CODE LM Test Report. For SIMKAR CORPORATION. (Brand Name: ) LED Lamp. Model name(s): SALXS350U1. Model differences: N/A

NVLAP LAB CODE LM Test Report. For SIMKAR CORPORATION. (Brand Name: ) LED Lamp. Model name(s): SALXS450U1. Model differences: N/A

Photometric Test Report

LM Test Report. For. Beyond LED Technology. (Brand Name: Beyond LED) 2725 Mountain Industrial Blvd. Suite A-1 Tucker, GA 30084

Photometric Test Report

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006

Cat# LED High Bay

Maxlite Jersey Blvd Rancho Cucamonga, CA Electrical and Photometric tests as required by the IESNA test standards.

Model No Stock No Calibration Due Date Chroma Programmable AC Source PS-AC02

Model No Stock No Calibration Due Date Chroma Programmable AC Source PS-AC02

1 General 1.1 Product Information Manufacturer Maxlite.Inc Page 2 of 17 Manufacturer Address 12 York Ave West Caldwell, NJ Brand Name Luminaire

GM LIGHTING 9830 W 190th St, Torrance, CA 90503

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Fixture is tested with no special conditions.

NVLAP LAB CODE LM Test Report. For. LED Wav es,inc. (Brand Name: LED Wav es)

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

LED Entryway Light RoHS

NVLAP LAB CODE LM Test Report. For. Shenzhen Guanke Technologies Co. Ltd. (Brand Name: )

Test report of IES LM Approved Method: Electrical and Photometric

Wet Locations Use 71400A 120 W PF V 2.9A 93% 144 pcs. Philips 130 LM/W 5000K Hrs. 5 Years. 24-1/4 Lbs 665*530*120 1 PCS

ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION

Transcription:

Report Number: Model: PL09299-001A ARE-EHO-AF-xx-12-E-UL-xx-1000-xxxx-40K Date: 09/15/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Tammy Lehrmann Cree, Inc. 9201 Washington Avenue Racine, WI 53406 Prepared By: Approved By: Linjie Li, LC, Test Engineer Christopher McLaurin, Photometric Specialist C r e e, I n c 9 2 0 1 W a s h i n g t o n A v e n u e R a c i n e, W I 5 3 4 0 6 Page 1 of 13 This report contains data that are not covered by the NVLAP accreditation. This report also contains integrating sphere data that was produced under subcontract by Cree Engineering Services Testing Laboratory NVLAP Code 500077-0.

Product Information Manufacturer Model Number (SKU) Serial Number LED Type Cree, Inc. ARE-EHO-AF-xx-12-E-UL-xx-1000-xxxx-40K PL09299-001 XP-G2 Product Description Brown metal housing with two end caps. Four heat sinks each with one LED board and brown metal trim plate. One clear plastic optical lens below each LED. Driver Information (Where Applicable) 2x Cree LE098X01 Length Width Height 43.0 17.0 5.0 Sample The following sample was submitted for evaluation C r e e, I n c 9 2 0 1 W a s h i n g t o n A v e n u e R a c i n e, W I 53406 Page 2 of 13

Key Photometric Data Sphere Output Goniophotometer Luminous Flux 38571.0 38346.2 lm Efficacy 90.65 90.06 lm/w Correlated Color Temperature (CCT) 3979 K Color Rendering Index (CRI) 74 R 9-13 Duv -0.000741 S/P Ratio* 1.51 Sphere Goniophotometer Electrical Measurements 120V 277V 120V 277V Input Wattage 425.50 412.90 425.80 411.80 W Input Current 3.56 1.53 3.56 1.53 A Input Voltage 119.92 276.96 120.09 277.02 V Power Factor 0.997 0.972 0.997 0.973 Off-State Power 0 0 0 0 W Total Harmonic Distortion (Voltage) 0.19 0.09 0.14 0.06 % Total Harmonic Distortion (Amperage) 6.10 10.33 5.89 9.81 % Note: All photometric measurements taken at 120VAC. Luminous Intensity Distribution Goniophotometer Max Candela 26,497.9 Cd Angle of Max Candela (Horizontal) 70 Angle of Max Candela (Vertical) 30 Key Test Parameters Sphere Output Goniophotometer Stabilization Time 85 63 min Total Operating Time (Stabilization + Test) 85 83 min Ambient Temperature 24.6 24.9 C C r e e, I n c 9 2 0 1 W a s h i n g t o n A v e n u e R a c i n e, W I 53406 Page 3 of 13

Chromaticity Coordinates** NVLAP Lab Code 500089-0 x y u v u v Duv 0.3808 0.3754 0.2259 0.3340 0.2259 0.5010-0.000741 Color Rendering Index Details** Ra R1 R2 R3 R4 R5 R6 R7 R8 R9 R10 R11 R12 R13 R14 74 73 79 83 75 72 70 81 59-13 49 72 48 73 90 Chromaticity Diagram** C r e e, I n c 9 2 0 1 W a s h i n g t o n A v e n u e R a c i n e, W I 53406 Page 4 of 13

Spectral Distribution** NVLAP Lab Code 500089-0 λ(nm) W/nm λ(nm) W/nm λ(nm) W/nm 360 0.001436 530 0.502547 700 0.088436 370 0.001158 540 0.548743 710 0.066854 380 0.000932 550 0.582975 720 0.050280 390 0.001914 560 0.613825 730 0.037797 400 0.004192 570 0.641031 740 0.028179 410 0.021731 580 0.665785 750 0.021451 420 0.112656 590 0.668391 760 0.016361 430 0.350321 600 0.648000 770 0.012280 440 0.646782 610 0.604992 780 0.009435 450 0.604309 620 0.539359 790 0.007470 460 0.258980 630 0.468307 800 0.005594 470 0.129622 640 0.392077 810 0.004441 480 0.088940 650 0.319345 820 0.003376 490 0.109715 660 0.255364 830 0.002660 500 0.196776 670 0.198111 510 0.320095 680 0.152621 520 0.428280 690 0.116342 Dominant Wavelength** 579 nm Peak Wavelength** 444 nm Spectral Power Distribution (W/nm) ** C r e e, I n c 9 2 0 1 W a s h i n g t o n A v e n u e R a c i n e, W I 53406 Page 5 of 13

Zonal Lumen Summary NVLAP Lab Code 500089-0 Zone Lumens % of Total Zone Lumens % of Total 0-5 238.3 0.6% 90-95 0.0 0.0% 5-10 811.0 2.1% 95-100 0.0 0.0% 10-15 1522.8 4.0% 100-105 0.0 0.0% 15-20 2299.4 6.0% 105-110 0.0 0.0% 20-25 2993.9 7.8% 110-115 0.0 0.0% 25-30 3637.8 9.5% 115-120 0.0 0.0% 30-35 4038.2 10.5% 120-125 0.0 0.0% 35-40 4099.6 10.7% 125-130 0.0 0.0% 40-45 4215.0 11.0% 130-135 0.0 0.0% 45-50 4196.6 10.9% 135-140 0.0 0.0% 50-55 3696.4 9.6% 140-145 0.0 0.0% 55-60 2802.0 7.3% 145-150 0.0 0.0% 60-65 1847.6 4.8% 150-155 0.0 0.0% 65-70 1060.8 2.8% 155-160 0.0 0.0% 70-75 533.0 1.4% 160-165 0.0 0.0% 75-80 239.6 0.6% 165-170 0.0 0.0% 80-85 92.5 0.2% 170-175 0.0 0.0% 85-90 21.6 0.1% 175-180 0.0 0.0% Total 38346.2 lm 100% C r e e, I n c 9 2 0 1 W a s h i n g t o n A v e n u e R a c i n e, W I 53406 Page 6 of 13

Candela Plot Illuminance Plot Roadway Utilization Roadway Summary Lumens % Lamp Distribution TYPE II, VERY SHORT Downward Street Side 30,388.1 79.2% Downward House Side 7,958.6 20.8% Downward Total 38,346.6 100.0% Upward Street Side 0.0 0.0% Upward House Side 0.0 0.0% Upward Total 0.0 0.0% Total Lumens 38,346.6 100.0% C r e e, I n c 9 2 0 1 W a s h i n g t o n A v e n u e R a c i n e, W I 53406 Page 7 of 13

Luminaire Classification System C r e e, I n c 9 2 0 1 W a s h i n g t o n A v e n u e R a c i n e, W I 53406 Page 8 of 13

Candela Tabulations NVLAP Lab Code 500089-0 0 5 15 25 35 45 55 60 62.5 65 67.5 70 72.5 75 77.5 80 82.5 85 87.5 90 95 105 115 125 135 145 155 165 175 180 0 9305 9305 9305 9305 9305 9305 9305 9305 9305 9305 9305 9305 9305 9305 9305 9305 9305 9305 9305 9305 9305 9305 9305 9305 9305 9305 9305 9305 9305 9305 2.5 10747 11004 10964 10895 10818 10674 10504 10399 10354 10309 10236 10163 10102 10041 9991 9941 9879 9817 9745 9673 9565 9310 9098 8879 8661 8485 8338 8254 8216 8104 5 12309 12451 12499 12502 12502 12404 12167 12006 11910 11814 11684 11555 11421 11288 11163 11038 10908 10778 10648 10518 10292 9868 9488 9094 8710 8367 8015 7780 7663 7562 7.5 13125 13238 13389 13592 13844 13998 13921 13784 13683 13582 13424 13266 13071 12877 12671 12465 12257 12048 11866 11683 11383 10846 10289 9696 9027 8418 7823 7374 7132 7013 10 13862 14011 14225 14576 15017 15349 15458 15371 15305 15238 15086 14933 14708 14483 14216 13949 13667 13384 13141 12899 12525 11848 11095 10235 9320 8476 7665 7013 6607 6471 12.5 15065 15259 15435 15782 16220 16595 16834 16833 16807 16780 16642 16504 16280 16057 15751 15446 15066 14686 14333 13980 13496 12656 11711 10583 9468 8467 7520 6702 6154 6005 15 16624 16778 16937 17210 17551 17907 18249 18326 18307 18288 18145 18001 17750 17498 17133 16768 16256 15745 15246 14747 14102 13077 11923 10642 9453 8340 7297 6367 5705 5553 17.5 17971 18083 18262 18523 18844 19163 19476 19479 19429 19380 19229 19079 18824 18570 18189 17808 17214 16619 15984 15348 14559 13295 11792 10332 9091 7989 6926 5919 5200 5051 20 19051 19077 19230 19470 19718 19818 20074 20093 20066 20039 19949 19859 19651 19443 19087 18731 18074 17417 16648 15880 14964 13447 11516 9764 8399 7368 6311 5286 4616 4487 22.5 19598 19562 19708 20017 20355 20319 20523 20771 20827 20883 20846 20809 20636 20464 20090 19716 18982 18248 17323 16397 15313 13458 11112 8984 7430 6424 5474 4562 4029 3920 25 19758 19659 19825 20227 20861 21035 21441 21874 22070 22266 22313 22360 22180 22001 21520 21040 20122 19204 18056 16908 15593 13306 10519 8047 6313 5384 4594 3822 3455 3374 27.5 19406 19231 19619 20181 21100 21985 22894 23713 24109 24505 24646 24787 24533 24278 23632 22986 21792 20599 19120 17641 15907 12959 9695 6972 5158 4366 3797 3203 3035 2993 30 18254 18105 18963 20038 21286 22956 24069 25045 25582 26119 26308 26498 26124 25749 24962 24175 22750 21325 19612 17900 15962 12323 8623 5793 4095 3478 3129 2770 2789 2784 32.5 16927 16892 18113 19694 21473 23643 24668 25301 25618 25936 25980 26025 25624 25223 24411 23598 22055 20512 18693 16874 14982 11190 7366 4626 3185 2806 2642 2518 2685 2717 35 15682 15701 17249 19280 21621 23966 24798 24782 24718 24654 24474 24293 23835 23377 22567 21757 20171 18585 16760 14936 13202 9621 6042 3579 2460 2332 2297 2357 2744 2847 37.5 14341 14354 16184 18742 21645 24172 25130 24560 24126 23692 23181 22671 22036 21401 20523 19645 17991 16338 14566 12795 11263 8171 4935 2751 1948 1972 1991 2293 3151 3370 40 12587 12625 14826 17872 21416 24599 25748 24752 24077 23402 22632 21861 21044 20227 19310 18393 16719 15044 13461 11879 10549 7539 4210 2155 1605 1670 1695 2356 3524 3703 42.5 10870 10939 13172 16634 20798 25151 26128 24967 24236 23505 22660 21815 20925 20035 19162 18290 16664 15039 13630 12222 10752 7435 3796 1781 1395 1392 1411 2324 3374 3446 45 9294 9346 11534 15132 19808 25321 25962 24772 24178 23584 22826 22067 21183 20300 19340 18380 16574 14769 13502 12236 10851 7418 3576 1597 1263 1138 1217 2242 3141 3217 47.5 8014 8102 10046 13561 18467 24757 25114 24013 23652 23290 22624 21957 20956 19955 18843 17730 15896 14062 12978 11894 10542 7081 3270 1509 1135 944 1126 2167 2935 2995 50 7096 7176 8849 12108 16843 23176 23610 22726 22486 22247 21658 21070 20004 18939 17661 16383 14547 12712 11810 10909 9643 6188 2788 1378 948 808 1050 2006 2668 2682 52.5 6252 6343 7927 10808 15074 20595 21707 21192 20966 20740 20120 19500 18285 17070 15611 14152 12489 10826 10069 9311 8013 4764 2114 1128 748 706 951 1758 2301 2289 55 5359 5433 7026 9626 13346 17531 19629 19563 19231 18899 18086 17272 15833 14394 12853 11312 9940 8570 7898 7226 6084 3271 1417 800 585 625 844 1504 1964 1956 57.5 4400 4510 6201 8581 11654 14642 17389 17450 16877 16303 15166 14029 12432 10836 9444 8052 7066 6080 5577 5074 4186 2121 890 543 464 552 751 1311 1742 1771 60 3537 3694 5443 7599 9948 12048 14676 14600 13861 13122 11731 10340 8853 7365 6258 5150 4543 3936 3611 3285 2709 1422 602 402 387 484 661 1181 1598 1610 62.5 2842 3069 4725 6537 8152 9515 11544 11414 10458 9501 8248 6995 5847 4699 3978 3258 2895 2533 2328 2123 1762 1045 481 346 336 419 570 1037 1396 1391 65 2330 2540 3923 5261 6282 6907 8538 8178 7316 6454 5644 4835 4128 3420 2917 2414 2121 1829 1669 1509 1280 835 412 308 296 352 478 843 1147 1130 67.5 1802 1932 2980 3839 4352 4581 5812 5572 5082 4592 4156 3720 3305 2890 2475 2059 1761 1462 1313 1163 982 672 352 273 257 283 378 603 857 834 70 1273 1352 2082 2590 2681 2695 3630 3741 3530 3319 3121 2924 2692 2459 2145 1831 1518 1206 1055 904 752 516 292 238 218 223 284 422 618 583 72.5 935 1029 1518 1824 1674 1509 2104 2312 2276 2239 2192 2145 2034 1924 1774 1623 1358 1092 921 751 600 408 235 202 178 180 225 333 462 448 75 758 809 1139 1286 1053 813 1134 1324 1383 1442 1459 1476 1414 1352 1305 1258 1112 966 789 611 469 315 191 166 137 143 175 257 359 357 77.5 499 471 672 785 588 398 562 685 784 882 921 960 936 911 902 892 829 766 625 483 353 231 146 127 97 102 133 196 278 278 80 177 175 302 459 343 179 271 356 427 498 543 588 593 598 605 612 590 569 478 388 271 175 97 85 66 71 98 149 214 215 82.5 100 103 189 314 216 93 140 201 242 282 318 353 365 376 384 392 390 387 340 292 205 128 69 60 43 48 63 106 154 152 85 68 69 126 206 127 51 67 103 118 133 150 167 173 179 183 187 188 189 171 152 108 71 39 38 36 35 34 59 95 90 87.5 37 34 59 101 56 21 26 36 39 42 44 47 47 47 46 45 45 45 40 35 25 16 10 11 9 10 16 24 34 32 90 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 C r e e, I n c 9 2 0 1 W a s h i n g t o n A v e n u e R a c i n e, W I 53406 Page 9 of 13

Candela Tabulations (Continued) NVLAP Lab Code 500089-0 0 5 15 25 35 45 55 60 62.5 65 67.5 70 72.5 75 77.5 80 82.5 85 87.5 90 95 105 115 125 135 145 155 165 175 180 92.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 95 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 97.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 100 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 102.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 105 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 107.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 110 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 112.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 115 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 117.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 120 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 122.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 125 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 127.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 130 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 132.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 135 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 137.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 140 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 142.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 145 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 147.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 150 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 152.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 155 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 157.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 160 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 162.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 165 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 167.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 170 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 172.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 175 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 177.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 180 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 C r e e, I n c 9 2 0 1 W a s h i n g t o n A v e n u e R a c i n e, W I 53406 Page 10 of 13

Integrating Sphere Equipment List Description Manufacturer Model Serial Number 3M Sphere Labsphere CSTM-CSLMS-3M98-HDS 82456 CCD Array Spectrometer Otsuka MC-9801 98010165 Programmable AC Source Chroma 61603 616030000761 Single Channel Power Analyzer Xitron 2801 28011110008 Aux Lamp Power Supply Labsphere LPS-100-0833 1002104538 Goniophotometer Equipment List Description Manufacturer Model Serial Number AC Power Source Chroma 61602 616020002300 Type C Goniophotometer LSI / UL 6440T 6440PN2028 Spectroradiometer Gooch & Housego 770VIS/NIR 12415212 Power Meter Yokogawa WT210 91M945458 Test Methods Used: Title ANSI C82.77:2002 CIE Pub. 13.3:1995 CIE Pub. 15:2004 IES LM-58:1994 IES LM-65:2001 IES LM-79:2008 Description Harmonic Emission Limits- Related Power Quality Reqt s for Lighting Equipment Method of Measuring and Specifying Color Rendering of Light Sources Colorimetry Spectroradiometric Measurements Single-Ended Compact Fluorescent Lamps Life Test Performance Electrical and Photometric Measurements of Solid-State Lighting Products Reference Standard Used: Equipment 3m Sphere Type C Goniophotometer and Spectrometer Description Tungsten Halogen Omni-Directional 75W Calibration Lamp, Serial Number G141 Tungsten Halogen Omni-Directional 500W Calibration Lamp, Serial Numbers 13C069. 13C070, 13C071. For color calibration of spectrometer, 13C074. C r e e, I n c 9 2 0 1 W a s h i n g t o n A v e n u e R a c i n e, W I 53406 Page 11 of 13

Disclaimers: This report must not be used by the customer to claim product certification, approval or endorsement by NVLAP, NIST or any agency of the federal government. The results contained in this report pertain only to the tested sample. This report shall not be reproduced, except in full, without written approval of the RESTL. *Items marked with a single asterisk are not covered by the NVLAP accreditation. In the event that the recorded temperature is outside of 25 ± 1 C, this is considered a non-standard condition. ** In the event that testing is subcontracted, test results in this report marked with the symbol **, or noted as Sphere or Integrating Sphere, were performed by the subcontracted laboratory identified in the footer on the first page of this report. Subcontracted testing is strictly integrating sphere based. All other tests are performed using a Type C goniophotometer. The integrating sphere information in the equipment list, report items marked with **, or results specifically identified as Sphere or Integrating Sphere, are the actual equipment used, and test results produced, by the subcontracted laboratory when subcontracting is indicated on the cover page. Additional Comments: The photos below are intended to show the orientation and fixturing/set-up of the units under test. These are critical to understanding the results of the test given the sensitivity of many products and measurement systems to orientation and set-up considerations, and also for reproducing the conditions of the test. Goniophotometer Integrating Sphere C r e e, I n c 9 2 0 1 W a s h i n g t o n A v e n u e R a c i n e, W I 53406 Page 12 of 13

Document Revision History: Each subsequent revision of this report replaces the preceding report. Date Rev DCN # Change at the time of this test By Approval 09/15/16 A DMS Origination L. Li C. McLaurin C r e e, I n c 9 2 0 1 W a s h i n g t o n A v e n u e R a c i n e, W I 53406 Page 13 of 13