XMM-Newton SOC Technical Note

Similar documents
XMM-Newton Calibration Technical Note

ENERGY SCALE IN EPIC-PN TIMING MODE

XMM-Newton Calibration

The Behaviour of the XMM-Newton Background: From the beginning of the mission until May XMM-SOC-GEN-TN-0014 issue 3.10

RGS CALIBRATION STATUS

XMM-Newton. XMM-Newton Science Analysis System 12.0 scientific validation. XMM-SOC-USR-TN-0019 Issue 1.1

Analysis of extended sources with the EPIC cameras

High Resolution X-Ray Spectra A DIAGNOSTIC TOOL OF THE HOT UNIVERSE

The X-Ray Universe. Potsdam University. Dr. Lidia Oskinova Wintersemester 2008/09

X-ray data analysis. Andrea Marinucci. Università degli Studi Roma Tre

XMM-Newton - Chandra Synergy: Maximizing their Future Science Impact over the Next Decade

Evaluation of the capabilities of the XMM-Newton SciSim from the EPIC calibration point-of-view. André Burzlaff, FH Aachen

The Non Equilibrium Ionization Model in ISIS

Temporal &Spatial Dependency of the MOS RMF

Rotation of the Hot Gas around the Milky Way. Edmund Hodges-Kluck Matthew Miller and Joel Bregman University of Michigan

XMM-Newton Chandra Blazar Flux Comparison. M.J.S. Smith (ESAC) & H. Marshall (MIT) 7 th IACHEC, Napa, March 2012

XMM-Newton Observations of the Isolated Neutron Star 1RXS J / RBS 1774

NuSTAR observation of the Arches cluster: X-ray spectrum extraction from a 2D image

XMM-Newton. XMM-Newton Science Analysis System 15.0 scientific validation. XMM-SOC-USR-TN-0026 Issue 1.0

Status of the EPIC calibration

arxiv: v1 [astro-ph.im] 11 Jul 2016

Where are oxygen synthesized in stars?

Mapping the non thermal emission in Coma cluster of galaxies using the FeXXV/FeXXVI line ratio

XMM-Newton Calibration Technical Note

arxiv:astro-ph/ v1 6 Oct 2002

MONTE CARLO METHODS FOR TREATING AND UNDERSTANDING HIGHLY-CORRELATED INSTRUMENT CALIBRATION UNCERTAINTIES

Comets observed with XMM-Newton

XMM-Newton. XMM-Newton Science Analysis System 17.0 scientific validation. XMM-SOC-USR-TN-0029 Issue 1.1

PoS(INTEGRAL 2012)090

The XMM-Newton EPIC background and the production of background blank sky event files. J. A. Carter and A. M. Read ABSTRACT

XMM-NEWTON OBSERVATIONS OF X-RAY EMISSION FROM JUPITER

EPIC OBSERVATIONS OF BRIGHT BL LAC OBJECTS: WHAT CAN WE LEARN FROM THE X-RAY SPECTRA ABOUT THE ISM

Observational appearance of strong gravity in X-rays

THE spectroscopic performance of large volume CdZnTe

arxiv: v2 [astro-ph.he] 27 Sep 2014

XMM-Newton Observations of the Toothbrush and Sausage Clusters of Galaxies

C. Watson, E. Churchwell, R. Indebetouw, M. Meade, B. Babler, B. Whitney

NAOYUKI TAMURA Subaru Instrument Astronomer Subaru Telescope, NAOJ

DAY LABORATORY EXERCISE: SPECTROSCOPY

COS FUV Dispersion Solution Verification at the New Lifetime Position

X-Ray observability of WHIM and our new mission concept DIOS Intergalactic. Oxygen. Surveyor ) Noriko Yamasaki ISAS/JAXA

XMM-Newton. Routine Calibration Plan. Version Edited by: M. J. S. Smith. September 6, Revision history

Impacts of focus on aspects of STIS UV Spectroscopy

Corrections for time-dependence of ACIS gain

A Fast Algorithm for Cosmic Rays Removal from Single Images

MEMORANDUM. Focal-Point: Point on the focal plane where the sharpest PSF is located.

arxiv: v1 [astro-ph.im] 14 Mar 2014

Lab 6: Spectroscopy Due Monday, April 10

Proposing to Observe an On-axis Point Source with ACIS

Probing Neutron Star Physics using Thermonuclear X-ray Bursts

VERITAS Observations of Supernova Remnants

arxiv:astro-ph/ v1 12 Nov 2003

Discovery of TeV Gamma-ray Emission Towards Supernova Remnant SNR G Last Updated Tuesday, 30 July :01

X-raying Galaxy Ecosystems of Disk Galaxies. Q. Daniel Wang IoA/Cambridge University University of Massachusetts

PoS(INTEGRAL 2012)049

Calibration of ACS Prism Slitless Spectroscopy Modes

Particle acceleration in Supernova Remnants

UNIVERSITY COLLEGE LONDON. Measuring a Stellar Spectrum

Southern African Large Telescope

X-ray emission and variability of young, nearby stars

arxiv: v1 [astro-ph.he] 28 Mar 2019

The H.E.S.S. Standard Analysis Technique

PACS Wavelength Switching AOT release note

MEMORANDUM. Focal-Point: Point on the focal plane where the sharpest PSF is located.

A relativistically smeared line profile in the spectrum of the bright Z-source GX 340+0

A Cluster of Galaxies, Abell 496

arxiv:astro-ph/ v1 27 Sep 2004

JEREMY DRAKE, PETE RATZLAFF, VINAY KASHYAP AND THE MC CALIBRATION UNCERTAINTIES TEAM MONTE CARLO CONSTRAINTS ON INSTRUMENT CALIBRATION

arxiv: v2 [astro-ph.he] 22 Dec 2014

Chandra was launched aboard Space Shuttle Columbia on July 23, 1999!!!

Simultaneous XMM-Newton Radio Observations of the Mode-switching Radio Pulsar PSR B Wim Hermsen 1,2

Photometric and spectroscopic observations of the outburst of the symbiotic star AG Draconis between March and June 2016

Variation of the broad X-ray iron line in MCG± during a flare

PoS(extremesky2009)018

arxiv: v1 [astro-ph.he] 9 Feb 2010

Accuracy of VIMOS night-time and daytime wavelength calibrations

e e-03. which is distributed with standard chandra processing. visual inspection are included.

Detection of Artificial Satellites in Images Acquired in Track Rate Mode.

Publ. Astron. Obs. Belgrade No. 86 (2009), TURKISH NATIONAL OBSERVATORY (TUG) VIEW OF CLUSTERS OF GALAXIES

Calibration Activities the MOS perspective

The XMM-Newton (and multiwavelength) view of the nonthermal supernova remnant HESS J

arxiv: v2 [astro-ph.ep] 2 Nov 2017

Improving the Relative Accuracy of the HETGS Effective Area

PSF in-flight calibration for MOS 1 and MOS 2 cameras

Mimir NIR Spectroscopy Data Processing Cookbook V2.0 DPC

Few good reasons to hold the meeting in Cervia

(High Resolution) (X-ray) Spectroscopy of Supernova Remnants. Jacco Vink Utrecht University

Major Releases: BG analysis web page with recommended information, papers, summary tables etc:

Spectral Analysis of High Resolution X-ray Binary Data

The TV3 ground calibrations of the WFC3 NIR grisms

Life Cycle of Stars. Photometry of star clusters with SalsaJ. Authors: Daniel Duggan & Sarah Roberts

The Challenge of AZ Cas-Part 1. John Menke Barnesville, MD Abstract

X-ray spectroscopy: Experimental studies of Moseley s law (K-line x-ray fluorescence) and x-ray material s composition determination

Supplemental information for Positron-Induced Luminescence. Abstract

Hughes et al., 1998 ApJ, 505, 732 : ASCA. Westerlund, 1990 A&ARv, 2, 29 : Distance to LMC 1 ) ) (ergs s F X L X. 2 s 1. ) (ergs cm

Open Cluster Photometry: Part II

Wavelength Calibration Accuracy for the STIS CCD and MAMA Modes

Gravitational-Wave Data Analysis: Lecture 2

1. Give short answers to the following questions. a. What limits the size of a corrected field of view in AO?

Multi-instrument, multiwavelength. energy sources with the Virtual Observatory

Transcription:

XMM-Newton SOC Technical Note XMM-SOC-CAL-TN-0082 Accuracy of energy reconstruction in EPIC-MOS Timing Mode M. Guainazzi April 6, 2009 History Version Date Editor Note 1.0 April 6, 2009 M.Guainazzi SASv8.0 1

XMM-Newton SOC Technical Note XMM-SOC-CAL-TN-0082 Page: 2 1 Motivation and methodology In the report I study the accuracy of the energy reconstruction in EPIC-MOS Timing Mode. For this purpose I analyzed the spectra of two bright, line-rich SuperNova Remnants (SNRs: Cas A, and N132D) observed before the micro-meteoroid impact in Rev.#961 (Guainazzi 2009). The centroid energy of the strongest emission lines measured in these spectra has been compared with that simultaneously measured by EPIC-pn Full Frame exposures and with exposures of the same targets taken in MOS imaging modes (Full Frame and Large Window; Sect. 3.1). The nominal energy reconstruction accuracy in imaging modes is ±10 ev for the three EPIC cameras over their whole sensitive bandpass (Guainazzi 2009). Furthermore, the best-fit phenomenological model for the RGS spectra of the star AU Microscopii (Rev.#155) has been compared with a simultaneous MOS2 Timing Mode spectrum, to cross-check that the results obtained with the aforementioned reference targets are not affected by the extended nature of their X-ray emission. 2 Data reduction Table 1 shows the list of observations discussed in this report. In Obs.#0129341101 and #0165560101 a only MOS2 Table 1: List of observations discussed in this report Source Obs.# MOS mode N132D 0129341101 Timing N132D 0210681301 Full Frame N132D 0157160301 Large Window CasA 0165560101 Timing CasA 0097610501 Large Window AU Microscopii 0111420101 Timing a the EPIC-MOS cameras were operated in Timing Mode, while the EPIC-pn camera was operated in Full Frame Mode. Given the large extension of these sources (>1 ) the pile-up fraction is negligible in all exposures [Bleeker et al. (2001) estimate an EPIC-pn pile-up fraction <3% in the brightest knots of Cas A, for instance]. Data were reduced with SASv8.0 (Gabriel et al. 2003) 1, using the most updated calibration files available at the date of the report s publication. Standard screening criteria were applied to the data, as defined by the #XMMEA EM and FLAG==0 selectlib expressions for EPIC-MOS and EPIC-pn, respectively. Single-events EPIC-pn time-averaged spectra were accumulated from circular regions around the apparent centroid of the X-ray source. EPIC-MOS Timing Mode time-averaged spectra 1 The Release Note for this SAS version is available at the following URL: http://xmm2.esac.esa.int/sas/8.0.0/documentation/releasenotes/xmmsas 8.0.0.shtml

XMM-Newton SOC Technical Note XMM-SOC-CAL-TN-0082 Page: 3 Table 2: Count rates and extraction regions for the observations discussed in this report. The MOS Timing Mode extraction regions are expressed in detector coordinate ranges (extrema included); the imaging modes extraction regions are circles centered around the apparent centroid of the X-ray image. Source Count rates (s 1 ) Extraction region ranges radii ( ) MOS 1 a MOS 2 a pn/rgs MOS 1 a (RAWX) MOS 2 a (RAWX) pn MOS b (FF/LW) N132D 18.14 ± 0.04 24.02 ± 0.04 77.59 ± 0.10 270-345 270-345 80 140/120 Cas A 76.01 ± 0.08 53.06 ± 0.07 251.5 ± 0.2 255-324 278-346 240 250/170 AU Mic... 2.852 ± 0.007 0.612 ± 0.003... 288-315..... a Timing Mode; b imaging modes. Cts s 1 kev 1 0.01 0.1 1 10 100 1000 CasA Obs.#0165560101 MgXII SXV CaXIX SiXIII ArXVII SiXIV SiXIII SiXVI 0.5 1 2 5 Energy (kev) NiXXVII FeXXIII Cts s 1 kev 1 0.01 0.1 1 10 100 1000 N132D Obs.#0129341101 OVII NeIX MgXI OVIII NeX MgXII SiXIII SXV ArXVII SiXIV 0.5 1 2 5 Energy (kev) Figure 1: The EPIC spectra of Cas A (left) and N132D (right) discussed in this report. The dashed lines indicate the laboratory energies of the transitions used in this report. Black: MOS1; red: MOS2; green: pn. were accumulated from ranges in RAWX. Spectra from the EPIC-MOS exposures in imaging mode were accumulated using the standard combination of single and double events (PATTERN <= 12) to maximize the signal-to-noise ratio. In Tab. 2 the size of the spectral extraction regions as well as the count rate in the energy range used for the spectral analysis (see later) is reported. Spectra have been analyzed in the 0.5-8 kev and 0.5-5 kev energy bands for Cas A and N132D, respectively. This ranges are smaller than the recommended energy range where EPIC-MOS spectra in Timing Mode are nominally calibrated (0.3 10 kev; see Fig. 1). They have been chosen in order to simplify the spectral modeling of these sources, by excluding energy ranges with poor signal-to-noise ratio or no detected emission lines. I modeled the spectra with the combination of two bremsstrahlung continua and as many Gaussian profiles as statistically required by the fit at a confidence level larger than 90% for one interesting parameter according to the F-test. The same confidence level is used to define the statistical errors on the centroid energies in this report. The spectra are shown in Fig. 1, where the dashed lines indicate the laboratory energy of the atomic transitions used in this report, according to the ATOMDB database (available at: http://xcx.harvard.edu/atomdb). The RGS spectra of AU Microscopii were extracted with rgsproc. Background spectra were

XMM-Newton SOC Technical Note XMM-SOC-CAL-TN-0082 Page: 4 Figure 2: Difference left) and percentage difference (right) between the centroid energies measured by the EPIC-MOS cameras (MOS 1: top; MOS 2: bottom) in Timing Mode and the EPIC-pn (Full Frame) as a function of the centroid energy as measured by the EPIC-pn. Empty (Filled) circles correspond to the N132D (Cas A) measurements. The dashed-dotted lines mark the ±10 ev and ±30 ev locus around the EPIC-pn energy. Only data points are shown, whose relative statistical error is smaller than 25% on both the pn and the MOS cameras. accumulated from standard offset positions of the observation field-of-view. The reference sky position for the aspect solution was set equal to the SIMBAD source coordinates: α 2000 = 20 45 09.5, δ 2000 = -31 h 20 m 27 s. The 0.3 2 kev RGS spectrum was fit with a combination of 1 thermal bremsstrahlung and 17 Gaussian lines (see Appendix A). 3 Results 3.1 EPIC camera cross-calibration In Fig. 2 I show the discrepancy between the energy measured by the MOS cameras in Timing Mode and simultaneous exposures of the same targets in pn Full Frame mode. These discrepancies are expressed either as the energy difference or as a percentage difference ( E MOS E pn E pn ) between the best-fit centroid energies. In Table 1 the mean and standard deviation of the energy differences are reported per camera and observation. At the 1-σ level they are 30 ev and 20 ev (basically camera-independent) for the N132D and CasA observations, respectively. Fig. 3 shows the same type of plot as in Fig. 2 for a comparison between MOS exposures in imaging and Timing modes. At the 1-σ level they are 30 ev and and 20 ev (basically camera-independent) for the N132D and CasA observations, respectively. Interestingly enough, the discrepancy has got opposite signs in N132D and CasA.

XMM-Newton SOC Technical Note XMM-SOC-CAL-TN-0082 Page: 5 Table 3: Mean and standard deviation (in ev) of the best-fit centroid energy differences measured by EPIC-MOS in Timing and imaging modes, and pn in Full Frame Mode Experiment N132D CasA pn vs. MOS1 12 ± 13 8 ± 12 pn vs. MOS2 15 ± 18 4 ± 17 MOS1 imaging versus Timing modes 11 ± 16 16 ± 8 MOS2 imaging versus Timing modes 10 ± 8 7 ± 4 Figure 3: The same plot as in Fig. 2 when MOS exposures in imaging and Timing modes are compared. Different targets and modes are color coded.

XMM-Newton SOC Technical Note XMM-SOC-CAL-TN-0082 Page: 6 Cts s 1 kev 1 Data/model ratio 5 1 2 5 2 1 0.5 1 1.5 2 XMM Newton AU Micriscopii Comparison between MOS2 data and RGS model 0.5 Energy (kev) 1 Figure 4: Left panel: RGS combined spectra of AU Microscopii (from BiRD; González-Riestra & Rodríguez-Pascual 2008); Right panel: MOS 2 spectrum (upper panel) and residuals in data/model ratio (lower panel) against the best-fit RGS model. The colors label the fit with: no gain shifting (red); constant offset gain (black); or linear gain shift (blue). Table 4: Parameters of the gain fit Xspec command applied to the MOS 2 spectrum of AU Microscopii when the best-fit RGS model is applied. Offset (ev) 18.3± 0.7 0.3 18.8 ± 0.4 Slope 1 fixed 1.00219± 0.00024 0.00007 MOS 2/RGS 1 normalization 97.8 ± 0.5% 98.0 ± 0.4 0.6 % 3.2 Comparison to the RGS model of AU Microscopii In the right panel of Fig. 4 we show the Au Microscopii MOS 2 spectrum in Timing Mode and the data/model ratio when the best-fit RGS model is applied in the 0.3 2 kev energy band. The three colors indicate the nominal spectrum (red), and the spectrum to whose response matrix an energy-dependent offset (black), and a linear gain correction (blue) had been applied. Only an overall normalization factor C was allowed to be free in the fit together with the Xspec gain fit parameters. The improvement from the first to the other two cases is evident. The corresponding gain fit parameters are shown in Tab. 4. A nominal shift of 19 ev is required for the optimal alignment between the RGS best-fit model and the energy as measured by the MOS2 camera. Such an offset is mainly driven by the Oviii Ly-α, Neix He-α and Nex Ly-α emission lines. The observed difference is unaffected by the systematic uncertainties of the RGS wavelength scale (0.7 mev at the Oviii energy). 4 MOS1 exposures in Timing Mode after Rev.#961 A new hot column appeared on MOS 1 CCD1 in Rev.#961 due to a micro-meteoroid event (Guainazzi 2009). The post-impact offset value in MOS1 Timing Mode is far too large for a meaningful correction to be possible. Users are advised to discard the affected column (which in Timing Mode

XMM-Newton SOC Technical Note XMM-SOC-CAL-TN-0082 Page: 7 calibrated event lists corresponds to RAWX=319) and the adjacent ones from the accumulation of any scientific products. Users are referred to the watchout item at: http://xmm2.esac.esa.int/sas/8.0.0/watchout/evergreen tips and tricks/mos1 timing.shtml, which outlines the SASv8.0-compliant procedure to generate a correct effective area file in these cases. 5 Summary and conclusions This report investigates the accuracy of the energy reconstruction in MOS Timing Mode exposures, by comparing the centroid energies of strong atomic transitions in line-rich SNRs and star spectra against the measurements of the same lines in imaging mode EPIC or RGS exposures. The distribution of the centroid energy differences between measurements in EPIC-MOS Timing Mode and EPIC-MOS or EPIC-pn in imaging mode is 30 ev ( 20 ev) in N132D (CasA). Occasional discrepancies up to 40 ev are observed at the iron line energies in MOS 2, which will deserve further investigation. These results are confirmed by the direct comparison between the EPIC-MOS2 and RGS spectra of AU Microscopii, which requires an energy-independent shift of the MOS2 response by 19 ev to be aligned with an RGS-based phenomenological model. Acknowledgments Careful reading and detailed comments by M.Santos LLeo and S.Sembay on an early version of this manuscript greatly improved the quality of the analysis and its presentation. Appendix A The model used to phenomenologically fit the RGS spectrum of AU Microscopii is shown below (in compact Xspec jargon): model wabs(bremss + 17*gaussian) 0.00887249 0.001 0 0 100000 1e+06 0.820706 0.05 0.0001 0.0001 100 200 0.0105081 0.01 0 0 1e+24 1e+24 1.021 1e-05 0 0 1e+06 1e+06 0.000516254 1e-06 0 0 1e+24 1e+24 0.9175 1e-05 0 0 1e+06 1e+06 1.27194e-05 1e-06 0 0 1e+24 1e+24 0.915 1e-05 0 0 1e+06 1e+06 0.000107945 1e-06 0 0 1e+24 1e+24 0.922 1e-05 0 0 1e+06 1e+06

XMM-Newton SOC Technical Note XMM-SOC-CAL-TN-0082 Page: 8 0.000370232 1e-06 0 0 1e+24 1e+24 0.905 1e-05 0 0 1e+06 1e+06 0.000273348 1e-06 0 0 1e+24 1e+24 0.8725 1e-06 0 0 1e+06 1e+06 0.000191336 1e-06 0 0 1e+24 1e+24 0.825 1e-05 0 0 1e+06 1e+06 0.000277688 1e-06 0 0 1e+24 1e+24 0.8175 1e-05 0 0 1e+06 1e+06 8.71875e-05 1e-06 0 0 1e+24 1e+24 0.812 1e-05 0 0 1e+06 1e+06 0.000101719 1e-06 0 0 1e+24 1e+24 0.77 1e-05 0 0 1e+06 1e+06 5.21715e-05 1e-06 0 0 1e+24 1e+24 0.774439 1e-05 0 0 1e+06 1e+06 0.000242041 1e-06 0 0 1e+24 1e+24 0.738854 1e-05 0 0 1e+06 1e+06 0.000131671 1e-06 0 0 1e+24 1e+24 0.726698 1e-05 0 0 1e+06 1e+06 0.00035069 1e-06 0 0 1e+24 1e+24 0.654 1e-05 0 0 1e+06 1e+06 0-1 0 0 10 10 0.00125406 1e-06 0 0 1e+24 1e+24 0.573998 1e-05 0 0 1e+06 1e+06 0.000389254 1e-06 0 0 1e+24 1e+24 0.561269 1e-05 0 0 1e+06 1e+06 0.000287203 1e-06 0 0 1e+24 1e+24 0.367616 1e-05 0 0 1e+06 1e+06 0.000524661 1e-06 0 0 1e+24 1e+24 References Bleeker et al., 2001, A&A, 365, 242 Gabriel C., et al., 2003, ASCA, 314, 759 González-Riestra R. & Rodríguez-Pascual P., 2008, Proceedings of the Workshop Astronomical Spectroscopy and Virtual Observatory, Eds.: M.Guainazzi & P.Osuna, 37 Guainazzi M., 2009, EPIC Calibration Status Document, XMM-SOC-CAL-TN-0018 2 2 available at: http://xmm2.esac.esa.int/docs/documents/cal-tn-0018.pdf

XMM-Newton SOC Technical Note XMM-SOC-CAL-TN-0082 Page: 9