5 FP
SRIS FP Working pressure 40 bar Style S Style Style T Style D Style V Style Z 5
Technical data Filter body (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) ypass valve: rass Reverse Flow: Steel (only for series 0) Pressure Maximum operating pressure: 40 bar (4 MPa) Test pressure: 60 bar (6 MPa) urst pressure: 50 bar (5 MPa) Pulsed pressure fatigue test,000,000 of cycles with pressure from 0 to 40 bar (4 MPa) Temperature From -5 C to +0 C Filter lement rea Filter element in stainless steel mesh Length Type 4 P065 P5 P0 74 50 064-950 00 700-650 645 5970 880 Values expressed in cm Pressure drops Δp ousing The curves are plotted using mineral oil with density of 0.86 kg/dm to ISO 968. Δp varies proportional with density. ypass valve Opening pressure 6 bar ±0% Other opening pressures on request. lements type Δp lements in microfibre series N-R: 0 bar lements in microfibre series -S: 0 bar lements in stainless steel mesh series N: 0 bar Oil flow from exterior to interior.,50,00 0,50 Filter ousing Check valve FP 065 / /4 Seals Standard Nitrile (NR) series Optional FPM series V Weights without filter elements (kg.) Length 4 0,00 0 5 50 75 00 5 FP 065.9 4. 5.7 FP 5 7.5 9.4 FP 0/ 4.5 6.5.5 5.5 Filter internal volumes (dm ) Length 4 FP 065 0.5 0.40 0.60 FP 5 0.55 0.85.0 FP 0/.5.95.80.50,50,00 0,50 Filter ousing Check valve FP 5 /4 Connections In-line Inlet/Outlet Style FP inlet/outlet 90 0,00 0 50 00 50 00 50 Compatibility odies compatible with: Mineral oils to ISO 94 - aqueous emulsions synthetic fluids, water/glycol. Filter elements compatible with: Mineral oils to ISO 94 - aqueous emulsions synthetic fluids, water/glycol. Nitrile (NR) seals series, compatible with: Mineral oils to ISO 94 - aqueous emulsions synthetic fluids, water/glycol. V series FPM seals, compatible with: Synthetic fluids type S-FDR-FDS-FDU To ISO 94 Filter ousing FP 0 - Check valve /4 /,50,00 0,50 0,00 0 00 00 00 400 500 54
Valves Pressure drop in bypass valve 5 FP 065 0 5 0 0 4 6 48 60 5 FP 5 0 5 0 0 4 48 7 96 0 5 FP 0-0 5 0 0 50 00 50 00 50 4,50 Pressure drop in reverse flow valves FP 0 -,00,50 0,00 0 70 40 0 80 50 - Reverse Flow - In filter direction 55
Dimensions FP065 85 Recommended maximum flow rate - Pressure drop of complete filter equal to Δp.5 bar. - Oil kinematic viscosity 0 mm /s (cst). - Density 0.86 kg/dm. - Connections of filter under test G /4. Filter Flow rate Flow rate Filter element l/min l/min Length type Series N Series 0 06 0 8 0 48 4 6 5 50 Indicator connection Plug T - Ch. 0 5 7 68 M5 05-0 0 06 45 5 0 60 57 6 64 6 Ø 68 5 8 77 M5 06-0 5 5 06 6 58 Ch. 0 0 79 78 6 84 8 00 5 94 9 M5 08 - Threaded Connections Depth 5 mm G / M8 G /4 M8 / NPT 5/6 UNC /4 NPT 5/6 UNC S 8 (/4-6 UNF) 5/6 UNC Ch. 4 by-pass Nr. holes S ( /6 - UN) Filter Length mm 5/6 UNC 46 00 46 79 0 0 56
FP5 Recommended maximum flow rate - Pressure drop of complete filter equal to Δp.5 bar. - Oil kinematic viscosity 0 mm /s (cst). - Density 0.86 kg/dm. - Connections of filter under test G. Filter Flow rate Flow rate Filter element l/min l/min Length type Series N Series 09,5 0 69 50 06 74 57 0 0 98 6 9 0 6 5 7 56 5 59 Ch. 0 y-pass Ch. 0 Ø 77 nr. holes 57, 48 Indicator connection Plug T - Ch. 0 Ø 95 M5 00-0 0 9 06 7 0 0 48 6 6 5 9 5 08 75 M5 0-0 50 6 06 5 40 0 9 70 6 95 79 5 96 M5 - Threaded Connections G /4 G /4 NPT NPT S ( /6 - UN) S 6 ( 5/6 - UN) Flanged Connections /4 S 000 psi/m S 000 psi/m /4 S 000 psi/unc S 000 psi/unc /4 S 6000 psi/m Depth 5 mm M0 M0 /8 UNC /8 UNC /8 UNC /8 UNC Depth 5 mm M0 M0 /8 UNC /8 UNC M0 /4 S 6000 psi/unc /8 UNC 40,5 Filter Length mm 60 7 448 57
FP0/ Only for FP 0 length 4 40 40 Ch. 59 Ch. 0 FP 0 y-pass Ch. 46 57 80 Indicator connection Plug T - Ch. 0 Ø 8 Ch. P0 50 mm P0 550 mm Oil drain plug G /8 - Ch. 8 Ch. 0 Ø 05 Style P0 standard maintenance from head. Style P0 maintenance option from housing base. 57 Outlet 80 50 FP Top Outlet y-pass Ch. 46 nr. 4 holes nr. holes 94 47 7,5 58
Recommended maximum flow rate - Pressure drop of complete filter equal to Δp.5 bar. - Oil kinematic viscosity 0 mm /s (cst). - Density 0.86 kg/dm. - Connections of filter under test G /. Filter Flow rate Flow rate Filter element l/min l/min Length type Series N Series 0 6 07 06 7 0 0 85 6 74 9 5 0 9 M5 45-0 48 9 06 70 0 0 76 00 6 95 5 440 78 M5 445-0 9 55 06 5 00 0 47 67 6 440 75 5 450 47 M5 465-0 54 98 06 75 0 0 40 75 4 6 447 8 5 467 4 M5 475 - Threaded Connections G /4 G / /4 NPT / NPT S 0 ( 5/8 - UN) S 4 ( 7/8 - UN) Flanged Connections (For FP 0) /4 S 000 psi/m / S 000 psi/m /4 S 000 psi/unc / S 000 psi/unc /4 S 6000 psi/m /4 S 6000 psi/unc Filter Length 4 mm 98 4 554 709 Depth 5 mm M M / UNC / UNC / UNC / UNC Depth 5 mm M M / UNC / UNC M / UNC 59
Spare parts FP 4 6 5g 5f 5d 5e 5a 5b 5c 5h 5m Pos. Description Qty. FP Series FILTR 065 - - 5 - - 0 - - - 4 Complete filter See order table Filter element See order table ypass assembly 0006 (NR) 0007 (NR) 0008 (NR) 0006 (FPM) 0007 (FPM) 0008 (FPM) 4 Non bypass assembly 0004 (NR) 0004 (NR) 00044 (NR) 0009 (FPM) 0009 (FPM) 00095 (FPM) 5 Seal kits NR FPM NR FPM NR FPM 005065 005076 005069 005080 00507 00508 5a Filter element O-Ring OR 400 OR 06 OR 44 Ø 4.99 x.5 Ø 6.65 x.6 Ø 9.69 x.5 5b 5c 5d 5e O-Ring for housing nti-extrusion ring Gasket O-Ring OR 59 OR 56 pcs. OR 50 Ø 55.56 x.5 Ø 64.77 x.6 Ø 88.57 x.6 Parbak 7 Parbak 44 pcs. Parbak 5 Ø 54.5 x Ø 6.96 x.8 Ø 89.6 x.8 000058 000046 000058 000046 000058 000046 (NR) (FPM) (NR) (FPM) (NR) (FPM) O-R 050 Ø.4 x.78 5f p or Non p O-Ring OR OR 087(NR 90 Sh ) OR 4 (NR 90 Sh ) Ø 5.88 x.6 Ø.89 x.6 Ø 6.4 x.6 5g p or Non p O-Ring OR 0 OR 07 OR 08 Ø 7.65 x.78 Ø 9.5 x.78 Ø 0.5 x.78 5h Protective seal 0065 006509 00650 5m Drain plug - - G /8 with seal 6 Indicator plug T TV - Indicators See order table 60
Filter assembly FP P 4 5 6 7 xample: FP 5 S G 0 P0 Filter element 4 6 7 xample: P 5 0 P0 - Size 6 - Filter elements Ordering information FP 8b 8a 065 5 0 - Filter length - Valves 4 (only for FP 0-) S D V Z T 4 - Seals Without bypass With bypass With bypass + chek valve* With Reverse Flow* (only for FP 0) With Reverse Flow + bypass (only for FP 0) With bypass + chek valve* (only for FP 0) *Reduced cross-section oilways 0 Inorganic microfibre µ 06 Inorganic microfibre 6 µ 0 Inorganic microfibre 0 µ 6 Inorganic microfibre 6 µ 5 Inorganic microfibre 5 µ M5 8 - Options a) Filter P0 P0 Pxx MP Standard filters ßx (c) 000 See page 0 Maintenance from base of housing (FP 0-4 only) Customer request b) Filter element P0 Stainless steel mesh 5 µ (style N only) 7 - Filter elements differential pressure N 0 bar R (Filter with Reverse Flow + bypass) 0 bar S (Filter with Reverse Flow) MP Filtri standard NR Pxx Customer request V FPM 5 - Connections Type 065 5 0 G G / G /4 G /4 G /4 G G /4 G G / G / G / NPT /4 NPT /4 NPT /4 NPT G4 /4 NPT NPT / NPT / NPT G5 S 8 S S 0 S 0 G6 S S 6 S 4 S 4 F - /4 S 000 PSI/M /4 S 000 PSI/M - F - S 000 PSI/M / S 000 PSI/M - F - /4 S 000 PSI/UNC /4 S 000 PSI/UNC - F4 - S 000 PSI/UNC / S 000 PSI/UNC - F5 - /4 S 6000 PSI/M /4 S 6000 PSI/M - F6 - /4 S 6000 PSI/UNC /4 S 6000 PSI/UNC - DIFFRNTIL INDICTORS (see page 5) MP Filtri - The filter functions as described in this bulletin are valid exclusively for original MP Filtri filter elements and replacement parts. ll rights reserved The data in this publication is marketing information. MP Filtri reserves the right to make changes to the product described herein at any time it deems fit in relation to technical or commercial requirements. The colors of the products shown on the cover are for illustration purposes only. Copyright. ll rights reserved. 6