Determination of the Halogen Elements in the Deep UV Region of the Spectrum by ICP - OES

Similar documents
110 Lowell Rd Hudson, NH USA Tel:

Product Descriptions and Offerings

U.S. EPA SW-846 Method 6010C using the Prodigy High Dispersion ICP

Hydride Generation for the Determination of As, Sb, Se and Bi Using the Teledyne Leeman Lab s Prodigy 7 ICP-OES

The Evolution of Inductively Coupled Plasma - Optical Emission Spectroscopy (ICP-OES)

Hydra-C Application Note: 1076

ICP-3000 Inductively Coupled Plasma Optical Emission Spectrometer

U.S. EPA SW-846 Method 6010C Using the Prodigy7 High- Dispersion ICP Introduction. Application Note - AN1305. Experimental

Innovative. Intuitive. Concentration (ppb) R = Versatile. Hydra II C Mercury Analyzer

The. Family of Mercury Analyzers. Hydra II AA Atomic Absorption Detection Liquid Samples

DETERMINATION OF TOTAL HALOGEN CONTENT IN HALOGEN-FREE FLUXES BY INDUCTIVELY COUPLED PLASMA AND SOME LIMITATIONS OF ION CHROMATOGRAPHY

atomic absorption spectroscopy general can be portable and used in-situ preserves sample simpler and less expensive

Today s Agilent Solutions for Determining Heavy Metals in Food using Atomic Spectroscopy

Analytical Performance & Method. Validation

Low Level Detection of Priority Inorganic Pollutants in Water. Anthony Neumann, MSc Darren Crichton, BSc

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

U.S. EPA Method 8270 for multicomponent analyte determination

Experiment. Quantification of Ascorbic acid by Fluorescence Spectroscopy1

PRINCIPLE OF ICP- AES

Ultra-fast determination of base metals in geochemical samples using the 5100 SVDV ICP-OES

Test Method: CPSC-CH-E

Determinations by Atomic Absorption Spectroscopy and Inductively Coupled Plasma-Atomic Emission

UV3000. Accurate, precise, and portable ambient gas point analyzer

PROCEDURES. Pharmacopeial Forum 2 Vol. 36(1) [Jan. Feb. 2009]

Fusion UV/Persulfate TOC Analyzer

Fast Analysis of Water Samples Comparing Axially-and Radially- Viewed CCD Simultaneous ICP-OES

Low cost, rapid and in situ accurate quantification of chloramines and ammonia

Optimizing Analytical Performance in ICP-OES Applications

Pharmacopeial Forum Vol. 36(1) [Jan. Feb. 2010] 1

Atomic Spectroscopy AA/ICP/ICPMS:

REX Evaluation Guide. American Micro Detection Systems Inc March Lane, Suite 200 Stockton, CA 95219

OES - Optical Emission Spectrometer 2000

Determination of Total Bromine and Iodine Emission Spectrometric Method (ICP-OES) EuSalt/AS

ICP-OES Application Note Number 35

Authors: C. Derrick Quarles, Jr. *, Patrick Sullivan, M. Paul Field, Hwan Kim, and Daniel R. Wiederin

Course Details. Analytical Techniques Based on Optical Spectroscopy. Course Details. Textbook. SCCH 211: Analytical Chemistry I

Determination of major, minor and trace elements in rice fl our using the 4200 Microwave Plasma- Atomic Emission Spectrometer (MP-AES) Authors

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

9/28/10. Visible and Ultraviolet Molecular Spectroscopy - (S-H-C Chapters 13-14) Valence Electronic Structure. n σ* transitions

C101-E116. Talk Letter. Vol.4 March 2010

OPTIMIZING METALS SAMPLE PREP

Chemistry 524--Final Exam--Keiderling May 4, :30 -?? pm SES

Spectrophotometry. Introduction

Determination of Pb, Cd, Cr and Ni in Grains Based on Four Chinese National Methods via Zeeman GFAAS

INTRODUCTION Atomic fluorescence spectroscopy ( AFS ) depends on the measurement of the emission ( fluorescence ) emitted from gasphase analyte atoms

Agilent G2350A Atomic Emission Detector (AED)

C101-E111. Talk Letter. Vol.2 February 2009

Chapter 12 Mass Spectrometry and Infrared Spectroscopy

Chapter 9. Atomic emission and Atomic Fluorescence Spectrometry Emission spectrophotometric Techniques

Cl 2(g) + NaCl + H 2 O. light. 2Cl. Once formed, the chlorine radical can react with the heptane as shown below: + Cl

1901 Application of Spectrophotometry

HIGH PERFORMANCE MASS SPECTROMETERS FOR EARTH AND PLANETARY SCIENCE

Atmospheric Analysis Gases. Sampling and analysis of gaseous compounds

Fusion UV/Persulfate TOC Analyzer

AS 101: Day Lab #2 Summer Spectroscopy

Key Analytical Issues: Sample Preparation, Interferences and Variability. Tim Shelbourn, Eli Lilly and Company

27-1 (a) Resonance fluorescence is observed when excited atoms emit radiation of the same

Enhancing the productivity of food sample analysis with the Agilent 7700x ICP-MS

Electronic Supplementary Information. In vivo photoacoustic mapping of lymphatic systems with plasmon-resonant nanostars

Analysis Repeatability of Trace and Major Elements in a Water Sample

The Agilent 7700x ICP-MS Advantage for Drinking Water Analysis

EMISSION SPECTROSCOPY

Translational Biomarker Core

Experiment #9. Atomic Emission Spectroscopy

Traceable UV-Vis Reference Materials

Far UV Performance of the LAMBDA 850/950 UV/Vis and UV/Vis/NIR Research Spectrophotometers

Emission of Light & Atomic Models 1

Fergus Keenan Shona McSheehy Julian Wills

Analytical Approaches to Arsenic

RoHS. Specification CUD8DF1A. Drawn Approval Approval. 서식 Rev: 00

NATIONAL ASSOCIATION OF TESTING AUTHORITIES (NATA) REQUIREMENTS FOR ACCREDITATION OF ICP-MS TECHNIQUES

V. LAB REPORT. PART I. ICP-AES (section IVA)

Atomic Absorption Spectroscopy

Advanced Lab Course. X-Ray Photoelectron Spectroscopy 1 INTRODUCTION 1 2 BASICS 1 3 EXPERIMENT Qualitative analysis Chemical Shifts 7

Analysis of Illegal Dyes in Food Matrices using Automated Online Sample Preparation with LC/MS

RoHS. Specification CUD8AF1C. 서식 Rev: 00

Multi-residue analysis of pesticides by GC-HRMS

INTERNATIONAL OLIVE COUNCIL

Ultra-sensitive High-speed Monitoring Technology for Trace-level Toxic Halogenated Hydrocarbon Compounds

The Investigation of Fertilizer Analyses Using Microwave Digestion and the Agilent 720-ES

White Paper. Overview: NDIR Definition:

Process Analyzer and Sampling Systems

GTEK Laboratory Atomic Absorption Spectrometer AAS6000 Brochure

Instrumental Technique: Cuvette. Md Rabiul Islam

DAY LABORATORY EXERCISE: SPECTROSCOPY

High Resolution Optical Spectroscopy

Chem 155 Midterm Exam Page 1 of 10 Spring 2010 Terrill

The Plus for your lab!

Observation of Atomic Spectra

SUPPORTING INFORMATION. A New Approach for the Surface Enhanced Resonance Raman Scattering (SERRS)

Characterisation & Use of Array Spectrometers

Introduction. Molecules, Light and Natural Dyes. Experiment

Spectroscopy. Page 1 of 8 L.Pillay (2012)

Application of the Prodigy ICP as a Multielement-Specific Detector in Chromatography

Ultra Sonic Sprayer Controlling Dust in Experimental Poultry Houses

á233ñ ELEMENTAL IMPURITIES PROCEDURES

Multi-element process analyzer

UNIVERSITI SAINS MALAYSIA. Second Semester Examination Academic Session 2004/2005. March KAA 502 Atomic Spectroscopy.

The Fundamentals of Spectroscopy: Theory BUILDING BETTER SCIENCE AGILENT AND YOU

C101-E107B UV Shimadzu UV-VIS-NIR Spectrophotometer

Transcription:

Prodigy ICP Series Technical Note Determination of the Halogen Elements in the Deep UV Region of the Spectrum by ICP - OES Introduction There are many applications where the ability to measure the halogen elements, at the same time as the metallic elements, is desirable. A few of these include the measurements of Cl and Br in refinery process fluids, the measurement of Cl and Br in waste oils and the determination of Cl -, Br - and I - in food supplements and drinking water. Historically, the wavelength range of commercially available ICPs has been limited to 165 to 800 nm. This has precluded the determination of the halogens because the primary emission lines for these elements reside between 134 and 154 nm. As a result of this historic limitation, other techniques such as ion chromatography, ion selective electrodes and combustion analysis ( e.g. organic elemental analysis or CHNOX) have been required for the determination of chlorine and bromine in most matrices. This application note describes a new feature of the Prodigy ICP which permits ppb level determinations of chlorine, bromine and iodine in the deep ultraviolet region of the ICP spectrum. The Prodigy H will be shown to provide the accuracy, precision and detection limits required to measure halogen elements. Shown: The Prodigy ICP Experimental Instrumental A Teledyne Leeman Labs Prodigy High Dispersion ICP equipped with the Halogen Option was used to collect the data for this technical note. 6 Wentworth Drive Hudson, NH 03051 U.S.A. Tel: 603 886 8400 Fax: 603 886 9141 www.leemanlabs.com

Prodigy-H incorporates several design elements which are critical to effective halogen measurements in the deep UV region of the ICP spectrum. These include: An Ultra-Clean Optical Spectrometer free from components that can outgas and absorb deep UV photons. Most optical systems contain printed circuit boards and other electronic components which seriously compromise deep UV light transmission. Deep UV Sensitive Detection System. Prodigy s detection system provides a stable, linear response down to 134 nm. Most solid-state detectors are not sensitive below 160 nm. High Efficiency Purge Path. With deep UV measurements, it is critical that the light path from the ICP torch to the entrance slit of the spectrometer be fully purged. Even a few millimeters of air will absorb nearly all of the deep UV light. The Radial and Axial Purge Paths used on Prodigy-H are shown in figures 1 and 2 respectively. Figure 1. Radial Purge Path Figure 2. Axial Purge Path Prodigy-H incorporates several other design features that are not only important for the determination of halogens, but are critical to the overall performance of the ICP for traditional metal measurements. A detailed review of these features can be found in the Prodigy brochure as well as at www.leemanlabs.com. 2

Discussion The spectral region containing the preferred emission wavelengths for Cl, Br are shown in Figure 3 along with a listing of the preferred wavelengths for Cl, Br and I in Table 1. Figure 3. Spectrum of Cl and Br Emissions. Element Wavelength, nm Cl 134.724 Br 154.065 I 183.038 Table 1. Preferred Wavelength for Cl, Br and Iodine Figure 4 shows a typical calibration curve for Chlorine in radial viewing mode. The calibration is linear from sub ppm levels up through the top end of this curve at 500 ppm. Higher concentrations were not explored in this work. The calibration data also shows that the deviations between the standard concentrations and the calculated values are small and the %RSDs of the replicate measurements are low. 3

Figure 4. Chlorine Calibration Data at 134.724 nm In an effort to explore the effectiveness of this new capability two NIST SRMs were analyzed for chlorine. These data are shown in Table 2, below. Chlorine Bovine NIST 1577 A Oyster Tissue NIST 1566 A 19.3 ppm 53.7 ppm 18.4 54.8 18.5 54.7 18.4 54.4 19.1 54.0 20.0 55.8 Average 19.0 Average 54.6 0.75 gms/100 ml 0.67 gms/100 ml factor 133.33 142.86 Measured Value 2533 ug/gm Measured Value 7800 ug/gm Cert Value 2800 Cert Value 8290 % Recovery 90.48 % Recovery 94.09 Table 2. 4

Conclusions Prodigy s Halogen Option provides the analyst access to analytes that have historically required alternative analytical techniques such as ion chromatography or ion selective electrodes. This technical note demonstrates Prodigy-H s fundamental capability to measure the halogen elements in the deep UV region of the spectrum as well as the linearity, accuracy and precision that can be expected from these measurements. The ability to measure Chlorine, Bromine and Iodine at sub ppm levels along with all of the conventional metals will help to improve the efficiency of today s laboratories. 5