Flow Measurement. SITRANS F M System information SITRANS F M electromagnetic flowmeters. 4/22 Siemens FI

Similar documents
SITRANS F flowmeters. SITRANS F US System information SITRANS F US Ultrasonic flowmeters 4/181

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

Electromagnetic Flowmeter

TF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8.

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

By-Pass. This voltage is proportional to the liquid level (threewire potentiometer circuit). The resistance reading can

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

Amir Hossein Parvardi 1

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

TF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

CORIOLIS MASS FLOW METERS FOR GAS AND LIQUID MEASUREMENT. Michael Keilty (Presented by Hubbard Donald) Endress + Hauser Flowtec AG

PHOENIX CONTACT - 04/2016. Features

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

SINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol

FLOW MEASUREMENT. INC 102 Fundamental of Instrumentation and Process Control 2/2560

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Capacitive Sensors. Contents

PTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30

Field mounted Temperature Transmitter TF212/TF212-Ex

Reflex-Radar BM 100 A

Glossary Innovative Measurement Solutions

Electronic pressure-independent characterised control valve EPIV

VersaFlow Ultrasonic clamp-on Flowmeter Specifications

Installation guide 862 MIT / MIR

TF 212 / TF 212-Ex. Field mounted temperature transmitter, Profibus PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels. ABB Instrumentation

ED 701 General Industry Pressure Transmitter

CoriolisMaster FCB130, FCB150, FCH130, FCH150 Coriolis mass flowmeter

tekcor TKC Multivariable Coriolis Flow Sensors

CALYS 80P. Field pressure calibrator with high accuracy 0.01%

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Field IT 50T Series Transmitters

Pressure transmitters for industrial applications MBS 32 and MBS 33

STATIC GAS MONITOR Type SGM/DEW Revision A of 20 aprile 2016

Pressure Measurement Single-range transmitters for general applications

Remote Display Unit. Installers Handbook Copyright 2001 AirSense Technology Ltd. LM Remote Display Unit Installers Handbook Issue 1.

5730A High Performance Multifunction Calibrator. Extended specifications

Operating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM / / 2014

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level

EPIV electronic pressure-independent characterised control valve EPIV

NUMERICAL ANALYSES OF ELECTROMAGNETIC FIELDS IN HIGH VOLTAGE BUSHING AND IN ELECTROMAGNETIC FLOW METER

PROline promag 53 Division 1

FXP DATASHEET JUNHO 2013

BTE5000 / PTE5000 / PTU5000 Series Precision differential pressure transmitters

5SJ4...-.HG Circuit Breakers to IEC and UL 489

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure

Ultrasonic Gas Flow Meter

ISEmax CAM40/CAS40. Technical Information

Operating instructions Magnetic-inductive flow meter SM6x04 SM7x04 SM8x04

DBS315 1-phase SIDE CHANNEL BLOWERS

Guidelines for the Installation of SYGEF Pipes, Fittings and Valves

From Flowmeter to Advanced Process Analyzer

INTERNATIONAL OIML D 25 DOCUMENT. Vortex meters used in measuring systems for fluids ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION

Digital Current Transducer HO-SW series I P N = A. Ref: HO 100-SW; HO 150-SW; HO 200-SW; HO 250-SW

Conductivity sensor for hygienic applications

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

Metallized polyester film capacitors MKT 470

792A AC/DC Transfer Standard

INFORMATION TECHNOLOGY SYSTEMS SPDs FOR 19 TECHNOLOGY. NET Protector Surge Arrester. Protects switches, HUBs and telecommunication

Page 1 of 16 Issue No. 0 of IECEx TUN X

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

DATA SHEET WIEGAND WIRE SENSOR WS-UTS-0-U0, WS-UFS-0-U0

TÜV NORD CERT GmbH Hanover Office Am TÜV Hanover Germany. Testing Laboratory Explosion Protected Equipment and Monitoring Devices

PRODUCT CATALOGUE PREssURE switch

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

S95.3U01 / S95.3U11. Head mounted temperature transmitters, programmable, Pt 100 (RTD), thermocouples, electrical isolation

für for T5-Lampen fluorescent in Multi-Lamp-Technologie

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006%

HR-Z SERIES Mild Radiation Resistance LVDT

DATA SHEET WIEGAND WIRE SENSOR WS-UTS-4-U0, WS-UFS-4-U0

Safety Precautions WARNING If critical situations that could lead to user s death or serious injury is assumed by mishandling of the product.

Reference Only Spec. No. JEFL243B 0003F-01 P 1/ 6

v = m / s Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes

Ref: HLSR 16-PW; HLSR 32-PW; HLSR 40-PW-000; HLSR 50-PW-000,

VersaFlow TWM 9000 Electromagnetic Flow Converter Technical Datasheet. Specification. Highlights. Electromagnetic product range.

Snubber MMKP 386 AC and pulse double metallized film capacitor

24 volts (0.25 amps current-limited)

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HC6H 400-S/SP1

CALIBRATION CERTIFICATE # 503

LEVEL CONTROLS. Selection Guide. Capacitance Calculations and Data For Selecting Robertshaw Level Control Instruments and Sensing Probes

MODEL: R7K4FML3. Remote I/O R7K4F Series. POWER INPUT DC power R: 24 V DC (Operational voltage range: ±10 %; ripple 10 %p-p max.)

Coriolis Mass Flowmeter. (MCM Series) 100% Customer Satisfaction MAXIFLO TM. Coriolis Mass Flowmeter Series MCM

Grounding and Shielding

CCS140 and CCS141. Technical Information. Sensors for free chlorine Amperometric, membrane-covered sensors for installation in the CCA250 assembly

POINTS OF CAUTION BEFORE USE...

O Plus Dry Bushing 69 kv system, 350 kv BIL, 3000 A. Table of contents

THM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist

Full Metal Variable Area Flow Meter and Counter

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet

Metso Concentration Measurement 3300

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HC5FW 500-S

CoriolisMaster FCB430, FCB450, FCH430, FCH450 Coriolis mass flowmeter

Transcription:

Function All are based on Faraday s law of induction: U M = B v d k U M = Measured voltage induced in the medium perpendicular to the magnetic field and the flow direction. The voltage is tapped at two point electrodes. B = Magnetic flux density which permeates the flowing medium perpendicular to the flow direction. v = flow velocity of medium d = internal diameter of metering tube k = proportionality factor or sensor constant V Sensor B U M diagnostics The diagnostic functions are all internal tools in the meter: Identification in clear text and error log Error categories: function; warning; permanent and fatal errors Transmitter self-check including all outputs and the accuracy Sensor check: coil and electrode circuit test Overflow Empty pipe: partial filling; low conductivity; electrode fouling Verificator (MAG 000 and 6000 ) The Verificator is an external tool designed for MAG 000 and MAG 6000 with MAG 0, MAG 0 F, MAG 30, MAG 30 P or MAG 0 W sensors to verify the entire product, the installation and the application. The goal is to improve operation, reduce downtime and maintain measurement accuracy as long as possible. The Verificator is highly advanced and carries out the complex verification and performance check of the entire flowmeter system, according to unique Siemens patented principles. The whole verification test is automated and easy to operate so there is no opportunity for human error or influence. The system is traceable to international standards and tested by WRc (Water Research Council). d Function and measuring principle of electromagnetic measurement An electromagnetic flowmeter generally consists of a magnetically non-conducting metering tube with an internal electrically non-conducting surface, magnet coils connected in series and mounted diametrically on the tube, and at least two electrodes which are inserted through the pipe wall and are in contact with the measured medium. The magnet field coils through which the current passes generate a pulsed electromagnetic field with the magnetic flux density B perpendicular to the pipe axis. This magnetic field penetrates the magnetically non-conducting metering tube and the medium flowing through it, which must have a minimum electrical conductivity. According to Faraday s law of induction, a voltage U M is generated in an electrically conducting medium, and is proportional to the flow velocity v of the medium, the magnetic flux density B, and the distance between the electrodes d (internal diameter of pipe). The signal voltage U M is tapped by the electrodes which are in contact with the medium, and passed through the insulating pipe wall. The signal voltage U M which is proportional to the flow velocity is converted by an associated transmitter into appropriate standard signals such as to ma. Verificator Stand alone Verificator to measure a number of selected parameters in the flow sensor and a transmitter which affects the integrity of the flow measurement Up to measurements can be stored in the Verificator The Verificator can be connected via a serial cable to a PC enabling download of the data. A Windows program enables printing and management of verificator reports. Verification - Steps Verification of a flowmeter consists of the following test routines:. Transmitter test. Flowmeter and cable insulation test 3. Sensor magnetism test / Siemens FI 0

. Transmitter test The transmitter test is the traditional way of on-site testing on the market and checks the complete electronic system from signal input to output. Transmitter test Using the excitation power output, which is generated to drive the magnetic field of the sensor, the verificator simulates flow signal to the transmitter input. By measuring the transmitter outputs the verificator calculates its accuracy against defined values. Test includes: Excitation power to drive the magnetic field Signal function from signal input to output Signal processing gain, offset and linearity Test of analogue and frequency output. Insulation test Flow Measurement The verification of the sensor magnetism is a "boost" test of the magnetic field coil. The test ensures that the magnetism behaviour is like the first time, by comparing the current sensor magnetism with the "fingerprint" which was determined during initial calibration and stored in the SENSORPROM memory unit. In the "boost" test the verificator changes the magnetic field in certain pattern and with high voltage to get quick stable magnetic condition. This unique test is fulfilled without any interference or compensation of surrounding temperature or interconnecting cabling. Changes in dynamic magnetic behaviour Magnetic influence inside and outside the sensor Missing or poor coil wire and cable connection Certificate The test certificate generated by a PC contains: Test result with passed or failed Installation specification Flowmeter specification and configuration Verificator specification with date of calibration ensuring traceability to international standards. Flowmeter insulation test The verification test of the flowmeter insulation is a cross talk test of the entire flowmeter which ensures that the flow signal generated in the sensor is not affected by any external influences. In the "cross-talk" test the verificator generates a high voltage disturbance within the coil circuit and then looks for any "crosstalk" induced in the flow signal circuit. By generating dynamic disturbances close-coupled to the flow signal, the flowmeter is tested for noise immunity to a maximum level: EMC influence on the flow signal Moisture in sensor, connection and terminal box Non-conductive deposit coating the electrodes within the sensor Missing or poor grounding, shielding and cable connection. 3. Sensor magnetism test Sensor magnetism test Description Verificator... 30 V DC,... V AC,... 30 V, 0 Hz... 30 V DC,... V AC,... 30 V, 60 Hz Order No. FDK-083F060 FDK-083F06 Note: It is mandatory to have the Verificator returned to the factory once a year for check and re-verification. Siemens FI 0 /3

Technical specifications Flowmeter Calibration and traceability To ensure continuous accurate measurement, flowmeters must be calibrated. The calibration is conducted at Siemens flow facilities with traceable instruments referring directly to the physical unit of measurement according to the International System of Units (SI). Therefore, the calibration certificate ensures recognition of the test results worldwide, including the US (NIST traceability). Flowmeter uncertainty Siemens offers accredited calibrations assured to ISO 70 in the flow range from 0.000 m³/h to 000 m³/h. Siemens Flow Instruments accredited laboratories are recognized by ILAC MRA (International Laboratory Accreditation Corporation - Mutual Recognition Arrangement) ensuring international traceability and recognition of the test results worldwide. A calibration certificate is shipped with every sensor and calibration data are stored in the SENSORPROM memory unit. [±% E] 3.0.8.6...0.8.6...0 0.8 0.6 0. 0.0 MAG 000 with MAG 0, MAG 0 F, MAG 0 W, MAG 30, MAG 30 P and MAG 6000 with MAG 0 (PFA), MAG 0 F (PFA) Flowmeter uncertainty V: Flow velocity E: Meter uncertainty as a percentage of measured value v 0. m/s (0.3 ft/s) --> E: ± 0. ± mm/s * v < 0. m/s (0.3 ft/s) --> E: ± (/v) % of measured value * MAG 0 W (Order No. 7ME6...) with DN 30... 0 v 0. m/s (0.3 ft/s) --> E: ± 0. ± mm/s v < 0. m/s (0.3 ft/s) --> E: ± (/v) % of measured value 0 3 6 7 8 9 [m/s] 0 3.3 6.6 9.9 3 6 3 6 30 33 36 39 [ft/s] [±% E] MAG 6000 and MAG 6000 I with MAG 0 (not PFA), MAG 0 F (not PFA), MAG 0 W, MAG 30 and MAG 30 P Flowmeter uncertainty.. V: flow velocity E: meter uncertainty as a percentage of measured value v 0. m/s (0.3 ft/s) --> E: ± ± mm/s * v < 0. m/s (0.3 ft/s) --> E: ± (/v) % of measured value *.0 * MAG 0 W (Order No. 7ME6...) with DN 30... 0 v 0. m/s (0.3 ft/s) --> E: ± ±. mm/s v < 0. m/s (0.3 ft/s) --> E: ± (/v) % of measured value 0.8 0.6 0. 0.0 0 3 6 7 8 9 [m/s] 0 3.3 6.6 9.9 3 6 3 6 30 33 36 39 [ft/s] / Siemens FI 0

Reference conditions Reference conditions (ISO 9 and DIN EN 9) Temperature medium C ± K (68 F ± 8 F) Temperature ambient C ± K (77 F ± 8 F) Supply voltage U n ± % Warming-up time 30 minutes Incorporation in conductive pipe section Inlet section x DN (DN 0/8 ) x DN (DN > 0/8 ) Outlet section x DN (DN 0/8 ) 3 x DN (DN > 0/8 ) Flow conditions Developed flow profile Additions in the event of deviations from reference conditions Current output As pulse output (± 0. % of actual flow + 0.0 % FSO) Effect of ambient temperature Display / frequency / pulse output < ± 0.003 %/K act. Current output < ± 0.00 %/K act. Effect of supply voltage < 0.00 % of measuring value on % change Repeatability ± 0. % of actual flow for v 0. m/s (. ft/s) and conductivity > μs/cm Certificates EN. EN. EN 3. Certificate of conformity, stating that the delivered parts are made of the material quality that was ordered Test report certificate, a non batch specific material analysis of the ordered material Material analysis certificate, a batch specific analysis of the material issued by an independent inspector Flow Measurement Siemens FI 0 /

Technical specifications General specifications PROFIBUS device profile 3.00 Class B Certified Yes, according to Profile for process control devices v3.00. MS0 connections MS connections MS connections Electrical specification DP Physical layer specifications Applicable standard EN 070 vol. Physical Layer (Transmission RS 8 technology) Transmission speed. Mbits/s Number of stations Up to 3 per line segment, (maximum total of 6) Cable specification (Type A) Cable design Two-wire twisted pair Shielding CU shielding braid or shielding braid and shielding foil Impedance 3 up to 6 Ω at frequencies from 3... MHz Cable capacity < 30 pf per meter Core diameter > 0.3 mm², corresponds to AWG Resistance < Ω per km Signal attenuation Max. 9 db over total length of line section Max. bus length 0 m at 0 kbit/s, up to. km at 93.7 kbit/s. Extendable by repeaters Electrical specification PA Physical layer specifications Applicable standard EN 070 Physical Layer (Transmission IEC-68- technology) Transmission speed 3. Kbits/second Number of stations Up to 3 per line segment, (maximum total of 6) Max. basic current [I B ] ma Fault current [I FDE ] 0 ma Bus voltage 9...3V (non Ex) Preferred cable specification (Type A) Cable design Two-wire twisted pair Conductor area (nominal) 0.8 mm (AWG 8) Loop resistance Ω/km Impedance 0 Ω ± % Wave attenuation at 39 khz 3 db/km Capacitive asymmetry nf/km Bus termination Passive line termination at both Max. bus length Up to.9 km. Extendable by repeaters IS (Intrinsic Safety) data Required sensor electronics FISCO Max. U I Max. I I Max. P I Max. L I Max. C I FISCO cable requirements Loop resistance R C Loop inductance L C Capacitance C C Max. Spur length in IIC and IIB Max. Trunk length in IIC Max. Trunk length in IIB Compact or remote mounted MAG 6000 I Ex de Yes 7. V 380 ma.3 V 0 μh 0 nf... Ω/km 0...mH/km 80... 0 nf/km 30 m km km PROFIBUS parameter support The following parameters are accessible using a MS0 relationship from a Class Master. MS0 specifies cyclic Data Exchange between a Master and a Slave. Cyclic services: Input (Master view) Parameter MAG 6000/MAG 6000 I Mass flow Volume flow Temperature Density Fraction A ) Fraction B ) Pct Fraction A ) Totalizer Totalizer ) Batch progress ) Batch setpoint Batch compensation Batch status (running...) Output (Master view) Set Totalizer + Set Mode Totalizer + Batch control (start, stop...) Batch setpoint Batch compensation ) Requires a SENSORPROM containing valid fraction data. ) Value returned is dependent on the BATCH function. When ON, Batch progress is returned. When OFF, TOTALIZER is returned. /6 Siemens FI 0

Selection of sensor Metric Flow Measurement m 3/h 0 000 0 000 000 000 000 000 000 00 0 0 0 0. 0. 0.0 0.0 0.0 0.00 0.00 0.00 0.000 0.000 DN00 DN800 DN0 DN600 DN0 DN0 DN00 DN900 DN800 DN700 DN600 DN00 DN0 DN00 DN30 DN300 DN DN0 DN0 DN80 DN6 DN0 DN DN DN6 DN3 DN DN DN DN0 DN 0,0 0. 0. 0.3 0.. I/min. 6 6 000 00 00 00 0 0 0 0. 0. 0.0 0.0 0.0 0.00 m/s I/s 000 000 000 00 0 0 0 0. 0. 0.0 0.0 0.0 0.00 0.00 0.00 0.000 0.000 0.000 0.0000 Sizing table (DN DN 00) The table shows the relationship between flow velocity v, flow quantity Q and sensor dimension DN. Guidelines for selection of sensor Min. measuring range: 0 to m/s Max. measuring range: 0tom/s Normally the sensor size is selected so that the nominal flow velocity v lies within the measuring range to 3 m/s. Example: Flow quantity of 0 m 3 /h and a sensor dimension of DN 80 gives a flow velocity of.7 m/s, which is within the recommended measuring range of to 3 m/s. Flow velocity calculation formula Units v = 73. Q / DN or v = 33.68 Q / DN v : [m/s], Q : [l/s], DN : [mm] v : [m/s], Q : [m 3 /h], DN : [mm] Link to "Sizing program": https://pia.khe.siemens.com/index.aspx?nr= Siemens FI 0 /7

Imperial MGD 000 00 0 0 0 0. 0. 0.0 0.0 0.0 0.00 0.00 0.00 0.000 0.000 0.000 0.0000 " 3" ½" " ½" 0.0 0.0000 0.0 0.0000 0.00 0.00000 0.00 0.00000 0.00 0.00000 0. 0. 0.3 0. 0.8. 3 30 33 f/s Flow velocity " /" 3/8" 78" 7" 66" " 8" " 0"/" 36" 3" 30" 8" " " 8" 6" " " " 8" 60" 6" " /" /8" /" GPM 00 000 0 000 0 000 0 000 000 000 000 000 000 00 0 0 0 0. 0. 0.0 I/min. 000 000 000 000 00 000 0 000 0 000 0 000 000 000 000 000 000 00 0 0 0 0. 0. 0.0 0.00 0.00 0.000 Sizing table ( / 78 ) The table shows the relationship between flow velocity v, flow quantity Q and sensor dimension size. Guidelines for selection of sensor Min. measuring range: 0 to 0.8 ft/s Max. measuring range: 0to33ft/s Normally the sensor size is selected so that the nominal flow velocity v lies within the measuring range 3 to ft/s. Example: Flow quantity of 00 GPM and a sensor dimension of 6" gives a flow velocity of.6 ft/s, which is within the recommended measuring range of 3toft/s. Flow velocity calculation formula Units v = 0.08 Q / (Pipe I.D.) or v = 83.67 Q / (Pipe I.D.) v : [ft/s], Q : [GPM], Pipe I.D. : [inch] v : [ft/s], Q : [MGD], Pipe I.D. : [inch] Link to "Sizing program": https://pia.khe.siemens.com/index.aspx?nr= /8 Siemens FI 0

Installation conditions Vibrations Strong vibrations should be avoided. In applications with strong vibrations, remote mounting of the transmitter is recommended. Flow Measurement For partially filled pipes or pipes with downward flow and free outlet the flowmeter should be located in a U-Tube. Install in U-tubes when pipe is partially filled Installation in vertical pipes Recommended flow direction: upwards. This minimizes the effect on the measurement of any gas/air bubbles in the liquid. The sensor must always be completely filled with liquid. Install in pipelines which are always full The sensor must always be completely filled with liquid. Therefore avoid: Installation at the highest point in the pipe system Installation in vertical pipes with free outlet Install in vertical pipes with upward flow direction Installation in horizontal pipes The sensor must be mounted as shown in the below figure. Do not mount the sensor as shown in the lower figure. This will position the electrodes at the top where there is possibility for air bubbles and at the bottom where there is possibility for mud, sludge, sand etc. Do not install in pipelines which can run empty Siemens FI 0 /9

Measuring abrasive liquids and liquids containing particles Recommended installation is in a vertical/inclined pipe to minimize the wear and deposits in the sensor. Potential equalization Install in vertical pipelines with upward flow direction if measuring abrasive liquids Inlet and outlet conditions min. x D i min. 3 x D i Potential equalization The electrical potential of the liquid must always be equal to the electrical potential of the sensor. This can be achieved in different ways depending on the application: Wire jumper between sensor and adjacent flange (MAG 0, MAG 30) Direct metallic contact between sensor and fittings (MAG 0 F) Build-in grounding electrodes (MAG 30, MAG 0 W) Optional grounding/protection flanges/rings (MAG 0, MAG 30, MAG 8000) Optional graphite gaskets on MAG 0 (standard for MAG 0 High Temperature) MAG 8000 installed in plastic or coated pipes: two grounding rings to be used. Grounding Installation between elbows, pumps and valves: standard inlet and outlet pipe sections To achieve maximum accurate flow measurement it is essential to have straight length of inlet and outlet pipes and a certain distance between the flowmeter and pumps or valves. It is also important to center the flowmeter in relation to pipe flange and gaskets. Ambient temperature-installation Temperature changes can cause expansion or contraction in the pipe system. To avoid damage on the sensor use of proper gasket and torque should be ensured. For more information see sensor instruction. MAG 30 (not PTFE), MAG 0 W: with earthing electrodes in conductive and non-conductive pipes (no further action necessary) M6 x 6 MAG 0, MAG 30 (PTFE): without earthing electrodes in conductive pipes (MAG 0 use graphite gasket) /30 Siemens FI 0

Flow Measurement Δp [psi].0 Δp [mbar] 0. 0.6 0 0.7 0.8 0.9 0.7 0.60 0 0 0. 30 0.30 Without earthing electrodes in non-conductive pipes use grounding ring (MAG 0 use graphite gasket) MAG 0 F grounding via process connections. MAG 8000 grounding see MAG 8000 pages. Vacuum 0. 0.07 0.060 0.0 0.030 3 V=8 m/s [ ft/sec.] V=7 m/s [3 ft/sec.] V=6 m/s [ ft/sec.] V= m/s [6 ft/sec.] 0.0 V= m/s [3 ft/sec.] 0.007 0.0060 0.00 0. 0. 0.3 V=3 m/s [ ft/sec.] V= m/s [6 ft/sec.] 0.0030 V=. m/s [ ft/sec.] Avoid a vaccum in the measuring pipe, because this can damage certain liners. Installation in large pipes α α 8 d d 0.00 0. 0. 0.6 0.7 0.8 0.9 d /d V= m/s [3 ft/sec.] Pressure drop as function of diameter reduction between reducers Example: Flow velocity (v) of 3 m/s ( ft/s) in a sensor with a diameter reduction DN 0 ( ) to DN 80 (3 ) (d /d = 0.8) gives a pressure drop of.9 mbar (0.0 psi). Ambient temperature Reduction in nominal pipe diameter The flowmeter can be installed between two reducers (e.g. DIN 8). Assuming that at 8 the following pressure drop curve applies. The curves are applicable to water. C (F ) 60 () 0 () 0 () 30 (86) (68) (0) 0 (3) Ambient temp. MAG 000/6000 MAG 6000 I/MAG 6000 I Ex de 0 7 0 C ( 67 7 30 F ) Temperature of medium Max. ambient temperature as a function of temperature of medium The transmitter can be installed either compact or remote. With compact installation the temperature of medium must be according to the graph. Siemens FI 0 /3

Sensor cables and conductivity of medium Compact installation: Liquids with an electrical conductivity μs/cm. Note For detection of empty pipe the minimum sensor conductivity must always be μs/cm and the maximum length of electrode cable when remotely mounted is 0 m ( ft). Special shield cable must be used. For DN, DN 3 or for 9" safety barrier remote mounting in Ex applications special cable cannot be used, empty sensor cannot be detected and the conductivity must be 30 μs/cm. For remote mounted CT installations the maximum cable length is 0 m (600 ft). Remote installation [μs/cm] Standard cable 300 Conductivity of medium 0 0 0 0 300 [m] 300 600 900 [ft] Cabel length Minimum conductivity of medium (using standard electrode cable) [μs/cm] Special cable 0 Conductivity of medium 0 30 0 0 0 300 00 00 [m] 300 600 900 0 Cable length 0 [ft] Minimum conductivity of medium (using special electrode cable) /3 Siemens FI 0