X- AND GAMMA RAY EXPOSURE CALCULATION OF SHIELDING

Similar documents
Units S H I E L D I N H = D Q. H: Dose equivalent (Sv) D: Dose (Gy) Q: Quality Factor. 1Sv = 1 J/Kg. 1Gy = 1 J/Kg

Proposed Room Requirements for CT System

Proposed Room Requirements for CT System

QUESTION 8 GIVEN. Electron beam kinetic energy = 20 MeV Peak current = 1 A Beam pulse length = 1 microsecond Beam pulse frequency = 10 Hz

1. What would be the dose rate of two curies of 60Co with combined energies of 2500 kev given off 100% of the time?

Radiation shielding for gamma stereotactic radiosurgery units

A study on the cost of concrete shielding in a standard radiotherapy facility room

Progress in Nuclear Science and Technology, Volume 6,

Available online at ScienceDirect. Physics Procedia 69 (2015 )

Minor Change Procedure Date: 04/15/2016 Page 1 of 8 POSTING AND LABELING FOR RADIOACTIVE MATERIALS AND RADIATION MACHINES

Chapter 4. QUANTIFYING THE HAZARD II: DATA & ANALYSIS. The dose equivalents for spheres in air with 10 cm radius centred at a point in the

Mitigation of External Radiation Exposures

Neutron and gamma ray fluences measurement at radial Beam Port 1 of TRIGA MARK II PUSPATI research reactor

Radiation Shielding for Megavoltage Photon Therapy Machines

ISO 354 INTERNATIONAL STANDARD. Acoustics Measurement of sound absorption in a reverberation room

Peter J. Biggs Ph.D. Massachusetts General Hospital Harvard Medical School Boston, MA 02114

Accelerator Facility Accident Report

Georgia Institute of Technology. Radiation Detection & Protection (Day 3)

Volume 1 No. 4, October 2011 ISSN International Journal of Science and Technology IJST Journal. All rights reserved

Answer - SAQ 1. The intensity, I, is given by: Back

RADIONUCLIDE INFORMATION

X-ray Interaction with Matter

Peter J. Biggs Ph.D., Massachusetts General lhospital, Harvard Medical School, Boston, MA 02114

RADIATION SAFETY GUIDELINES FOR NON-USERS

Derivation of factors for estimating the scatter of diagnostic x-rays from walls and ceiling slabs

Laboratoire National Henri Becquerel (CEA/LIST/LNHB), France (2) ENEA-Radiation Protection Institute, Bologna, Italy (3)

Accelerator Upgrade Problem

Specific Accreditation Criteria Calibration ISO/IEC Annex. Ionising radiation measurements

Industrial Hygiene: Assessment and Control of the Occupational Environment

Calculations of Photoneutrons from Varian Clinac Accelerators and Their Transmissions in Materials*

Shielding. Principles. Effectiveness. Materials FM Appendix B

WM 07 Conference, February 25 March 01, 2007, Tucson, AZ

H e a l t h P h y s i c s S e r v i c e s L t d

Chapter 16 Basic Precautions

Storing, using and disposing of unsealed radioactive substances in a Type C Laboratory: Extract of regulatory requirements

We have seen how the Brems and Characteristic interactions work when electrons are accelerated by kilovolts and the electrons impact on the target

CALCULATION OF SHIELDING AND RADIATION DOSES FOR PET/CT NUCLEAR MEDICINE FACILITY

Calibration Facility

LECTURE 4 PRINCIPLE OF IMAGE FORMATION KAMARUL AMIN BIN ABDULLAH

Density Question Paper 2

Initial Certification

Effects of High Energy Radiation on Mechanical Properties of PP/EPDM Nanocomposite

Test Report. RI Acoustic Lab. Measurement of Sound Absorption Coefficient for RockDelta NoiStop Noise Barrier. 20 Feb. 07

Nuclear Science Merit Badge Workbook

ESTIMATION OF 90 SCATTERING COEFFICIENT IN THE SHIELDING CALCULATION OF DIAGNOSTIC X-RAY EQUIPMENT

Planning and preparation approaches for non-nuclear waste disposal

APMP supplementary comparison of absorbed dose rate in tissue for beta radiation

Radiological Protection Principles concerning the Natural Radioactivity of Building Materials

Question. 1. Which natural source of background radiation do you consider as dominant?

Quality control of neutron-absorber materials for the nuclear fuel cycle, Principle of the JEN-3 neutron Backscattering gauge

Atomic and nuclear physics

Radiation safety of the Danish Center for Proton Therapy (DCPT) Lars Hjorth Præstegaard Dept. of Medical Physics, Aarhus University Hospital

Implementing the ISO Reference Radiations at a Brazilian Calibration Laboratory

Basic physics Questions

Determining the Need For External Radiation Monitoring at FUSRAP Projects Using Soil Characterization Data. Todd Davidson

CHARGED PARTICLE INTERACTIONS

Investigation Of The Effects Of Variation Of Neutron Source-Detector Distance On The Emitted Neutron Dose Equivalent

Outline. Radiation Interactions. Spurs, Blobs and Short Tracks. Introduction. Radiation Interactions 1

RADIOPHARMACY PURPOSE

RPR 29 CYCLOTRON RADIOCHEMISTRY LABORATORY

European Project Metrology for Radioactive Waste Management

TITLE: Air Kerma Primary Standard: Experimental and Simulation Studies on Cs-137

Higher -o-o-o- Past Paper questions o-o-o- 3.6 Radiation

PROTECTION AGAINST X RAYS AND GAMMA RAYS

City University of Hong Kong

NE 495 Elements of Nuclear Engineering

ISO INTERNATIONAL STANDARD

Shielding calculations with MCNPX at the European spallation source

Study on the density characterization of the CT image

ASSESSING LEAKAGE WORKLOADS OF MEDICAL LINEAR ACCELERATORS FOR IMRT AND TBI TECHNIQUES

Radiation Quantities and Units

Working Correctly & Safely with Radiation. Talia Tzahor Radiation safety officer Tel:

Turbines and turbine sets Measurement of emitted airborne noise Engineering/survey method

FRAME ANALYSIS. Dr. Izni Syahrizal bin Ibrahim. Faculty of Civil Engineering Universiti Teknologi Malaysia

BY G. FAILLA. serious for many years. This is true even in the. case of a single exposure or a few exposures taking

Department of Energy OffIce of Worker Protection Programs and Hazards Management Radiological Control Technical Position RCTP

Nuclear Fusion and Radiation

Production of X-rays. Radiation Safety Training for Analytical X-Ray Devices Module 9

STRUCTURAL ANALYSIS CHAPTER 2. Introduction

EXTERNAL EXPOSURE CONTROL RCT STUDY GUIDE Identify the four basic methods for minimizing personnel external exposure.

EXTERNAL EXPOSURE CONTROL 00ICP311 Rev. 00 (DOE 1.11)

University Environmental Health & Safety

Evaluate Shielding Design of the Brachytherapy Unit by Using Monte Carlo Simulation Code

Introduction. Neutron Effects NSEU. Neutron Testing Basics User Requirements Conclusions

Neutron Imaging System For level Interface Measurement

Gy can be used for any type of radiation. Gy does not describe the biological effects of the different radiations.

Ideas for an Interferometric Thermometer

Secondary Particles Produced by Hadron Therapy

Nat 5 W&R Prelim Revision

Hp(0.07) Photon and Beta Irradiations for the EURADOS Extremity Dosemeter Intercomparison 2015

2. Which of the following statements help(s) to explain why gas can fill the vessel containing it completely while liquid cannot?

Radioactivity III: Measurement of Half Life.

WM 05 Conference, February 27 March 3, 2005, Tucson, AZ DEVELOPMENT OF A STORAGE VESSEL AND SHIPPING PACKAGE FOR TRITIUM

Various Busduct Assemblies: Various Busduct Assemblies: Various Busduct Assemblies:

ISO INTERNATIONAL STANDARD

BRE Client Report. Aging of light pipe materials (4000 hours artificial ageing) Prepared for: James McGowan Monodraught. BRE Watford, Herts WD25 9XX

Part 2: Methods for special reverberation test rooms

Accelerator Facility Shielding Design

Radiation Shielding of Extraction Absorbers for a Fermilab Photoinjector

Health Physics Services Ltd

Transcription:

MINT/1/1996,164 MY9700895 *»'' X- AND GAMMA RAY EXPOSURE CALCULATION OF SHIELDING T f - «MALAYSIAN INSTITUTE FOR NUCLEAR TECHNOLOGY RESEARCH 7 8HE 1 INSTITUT PENYEUDIKAN TEKNOLOG! NUKI.EAR MALAYSIA BANGI, 43000 KAJANG, MALAYSIA TEL : 6-03 - 825 0510 FAX : 6-03 - 825 8262 i.

BANGI, 430O0 KAJANG SELANGOR DARUL EHSAN SUBJECT DOCUMENT NO ISSUING DATE NO OF PAGES X- AND GAMMA-RAY EXPOSURE ROOM ES MINT:P&P/9003)/(2)/2.6 1 December 1995 12 Prepared By DR. ABD NASSIR IBRAHIM (HEAD, NONDESTRUCTIVE EVALUATION PROGRAM) (MINT)

ISSUE DATE: 1/9/96 PAGE: 1 1. Scope This document presents the calculation of shielding thickness for an exposure room to be used for X- and gamma radiography using the following radiation source and radiation machine : - Maximum of 100 Ci Iridium-192 Source for gamma radiography, and -7mA and 300kV directional x-ray machine This calculation is for the purpose of fulfilling the requirement of the Atomic Energy Licensing Board (AELB) as a precondition for the approval of the design and construction of an exposure room in IKATAN. 2. Relevant Documents 2.1 ICRP Publication.3, 15 and 21. 2.2 Code of Practice on Radiation Protection in Industrial Radiography, AELB, 1995 3. Location The exposure room is located at the PUSAT LATIHAN INSTITUT KEJURUTERAAN TEKNOLOGI TENAGA NASIONAL (IKATAN), Mukim Dengkil, Bangi Selangor. Detail location of the exposure room known as Lab. 5 is given in Appendix 1, 2 and 3 4. Shielding Calculation 4.1 For Gamma Source (Iridium -192,100 Ci source) This calculation is based on the following considerations: -The exposure room is located at the first floor -The area/room around the exposure room, including the room immediately above it, is considered as clean area,thus accessible to the member of public. -Concrete to be used shall have a minimum density of 2.35 g/cm-*

ISSUE DATE: 1/9/96 PAGE 2 4.1.1 Primary Barrier a) Thickness of walls sorrounding the source -Maximum allowable transmission (B) is given by the following formula: PdT B= (ICRP Publ 15and21) (1) m/t -P (Maximum permissible exposure just outside the shielding) = 0.01 rem/week (for member of public) -d (distance in metres from source to position occupied) -the source will be about the centre, thus the nearest distance between the source to position occupied may be taken as 1 metres (This will allow the source to be positioned at any location as long as the distance to the shielding does not exceed 1 metre) -W (weekly workload in R/week at 1 meter) -For 100 Ci Ir-192, dose rate at 1 meter is 50 R/hr. -Maximum total working hour/week is 40 hr. -Thus W= 2000 R/week -U Use factor = 1 for all 4 walls and ceiling (ICRP Publ. 3)-These walls and ceiling will be routinely exposed to useful beam. -T (occupancy Factor) = 1 ( according to ICRP Publ 3) Under this circumstances: Transmission factor (B) = (0.01 X 1 X 1 )/ (2000 X 1 X 1) = 2X10-6

ISSUE DATE: 1/9/96 PAGE: 3 According to the transmission curve provided by ICRP 15 and 21, (See Fig. 1), thickness required to provide the protection is 80cm. Thus, the thickness of primary barrier (for all 4 walls) is 80 cm of concrete. b) Ceiling thickness For this calculation, equation 1 will be used with all parameters are similar except in this case it is assumed that the distance between the source to the ceiling at all time shall not less than 2 meters In this case: Transmission factor (B) = (0.01 X 2 X 2 )/ (2000 X 1 X 1) = 2 X 10-5 From Fig. 1, this transmission factor corresponds to the concrete ceiling thickness of 70.0 cm Thus, the required thickness of ceiling is 70.0 cm of concrete. 4.1.2 Secondary Barrier a. Scattered Radiation. This calculation is relevant only for door thickness. Maximum percentage of scattering is taken (as precaution). This occur when both the incident angle and angle of scattering are 45 (See Fig. 2, from ICRP 15 and 21). Energy from Iridium-192 is assumed to be equivalent to about 0.6 MV x-ray.

ISSUE DATE: 1/12/95 PAGE: 4 1. i i 1 1 1 i i i i i i i i i i i i i i i i - z - IO- 2 1 11II transmission > o 1 1 1 1 1 111 - IO- 5 V = - I0" 6 1 1 1 L_ 1 1 1 1 i i i i i i i i 0 25 50 75 100 125 150 concrete, cm Fig. 1: Broad-bearrI transmission of gamma rays from various radionuclides through concrete, clensity of 2.35 g/cc

DOCUMENT NO ISSUE DATE: 1/12/95 PAGE: 5 0.24 0.01 potential, MV Fig. 2 Variation with potential of the absorbed dose rate measured in air due to x-ray scattered at 90o from various materials The beam is obliquely incident on the thick scatterer. Percent scatterer is related to primary beam measurements in free air at the point of incidence. (ICRP Publ. 15 and 21)

ISSUE DATE: 1/9/96 PAGE: 6 According to ICRP 15 and 21 Maximum Allowable Transmission (B s ) for scattered radiation is given by the following formula: 00 Pd 2 P and T are equal to those in equation (1), i.e. 1. W may be taken as 2000 R/week (considering source to scatterer distance of 1 meter), S (% of absorbed dose rate scattered at 1 meter taken from Fig. 2) =0 085% d (the distance between the wall (opposite to the door-known as scatterer) to the door itself is taken as 3 metres Thus, 100x0.01x3x3 8 1 = = 0.053 2000x1x0.085 By referring to Fig.3 (as given by ICRP Publ. 15 and 21), the minimum thickness of lead door required for the transmission B of 0. 053 = 20 mm. b) Leakage Radiation Leakage radiation is not relevant while gamma projector is in use. While not in use the maximum allowable leakage radiation for the projector (class P), in accordance to the Code of Practice on RadiationProtection in Industrial Radiography, Part 11, Article 12.1.1 is 2 mrem/hr. This value is too small and in this case the radiation will be taken care by the primary and secondary barrier. 4.2 For X-ray Machine This calculation is based on the precondition that the x-ray machine is of directional type and it shall always be used with its primary beam directed toward the floor.

ISSUE DATE: 1/12/95 PAGE 7 1 Mill K i i i i 1 1 1 1 1 111, MM' I I 1 1 M transmission,o- IO- 2 irr* M V > s w "Au To IQ-5 v X : io- 6 1 1 1 1 i i i i > () ' 5 10 15 20 25 30 lead, cm " > ; -1 - - Fig: 3 Broad beam transmission of gamma rays from various radionuclides through lead, density 11.35g/cc

ISSUE DATE: 1/9/96 PAGE: 8 4.2.1 Primary Barrier Since the useful beam will be directed to the floor and the room is located at the ground floor, then the primary barrier need not to be caclulated ( Floor is the only primary barrier). 4.2.2 Secondary Barrier a. Scattered Radiation. This calculation may be divided into two sections; a.i. Thickness of walls sorrounding the machine: According to ICRP 15 and 21 Maximum Allowable Transmission (B s ) for scattered radiation is given by the following formula: B 100 Pd: WTS P and T are equal to those in equation (1), i.e. 1. W may be taken as 16800 ma min/week (machine capacity is 7mA, total working minute in a week is considered as 2400 mins.) S is taken as a maximum % incident absorbed dose rate scattered to 1 meter per 100 cm2 irradiated area. In this case the worst case is taken where maximum scattering occur at angles between 160 to 180.According to Fig. 4, this value is 0.073% (backscattered). d (the distance between the floor( known as scatterer) to the wall is taken as 1 metres. Thus, 100x0.01x1x1 Bs = = 8.2x10 4 168OOxlx.O73

ISSUE DATE: 1/12/95 PAGE 9 1 ' 1 ' i i i I i i i i i i i irradiated area 0.02 1 scattering s angle - 0.08 100 cm c t beam > '. m per sttered to 1 0.015 A /K)0to300 kv 0.06 : ; absorbed dose c % incide 0.01 0005 : /, / / /. 6MV 0.04-0Yi i i 90 i i i i i i i i i 120 150 K scattering angle, degrees Fig 4. Scattering patterns of diverging x-ray and gamma ray beams normally incident on a concrete shield. Percent scatter is related to primary beam measurements in free air at the point of incidence (ICRP Publ. 15 and 21)

ISSUE DATE: 1/9/96 PAGE: 10 Once again by referring to Fig. 1 (as given by ICRP Publ. 15 and 21), the minimum thickness of these walls for the transmission B of 8.2x10"^= 48.0cm This thickness is much smaller than the thickness calculated for the walls to attenuate the radiation due to Indium-192 source, i.e.80.0cm a.ii. Thickness of ceiling As in the previous case, according to ICRP 15 and 21 Maximum Allowable Transmission (B s ) for scattered radiation is given by the following formula: B = wrs P and T are equal to those in equation (1), i.e. 1. W once again may be taken as 16800 ma min/week (machine capacity is 7mA, total working minute in a week is considered as 2400 mins.) S is taken as a maximum % incident absorbed dose rate scattered to 1 meter per 100 cm2 irradiated area (Fig.3), i.e. 0.073% d (the distance between the floor( known as scatterer) to the wall is taken as 3 metres (room height). Thus, 100x0.01x3x3 Bs= = 7.3x10~ 3 16800x1x073 By referring to Fig. 1 (as given by ICRP Publ 15 and 21), the minimum thickness of the ceiling for the transmission B of 7.3x10" 3 = 35.0cm This thickness is much smaller than the thickness calculated for the ceiling to attenuate the radiation due to Iridium-192 source, i.e. 70.0cm

ISSUE DATE: 1/9/96 PAGE: 11 b. Leakage Radiation Barrier for leakage radiation is given in ICRP 15 and 21 as follows: WJ -jtf (3) where Njyj is the number of tenth value thickness, T, d and p are similar to those in equation 1 (d is taken as 1 meter), and WL is the weekly leakage exposure rate. ICRP Publication 15 and 21, edition 1976 gives the value of Leakage radiation for an x-ray machine operating between 200kV to 400kV = 1 R/hr Thus WL= 40 R/week. 4O.vl jvnt rit = Lov = 3.6 * 10 l.vlxo.01 TVT for concrete when using x-ray source of 300 kv is given as 3.0cm. Thus the thickness required due to leakage radiation is 3x3 6cm=10.8 cm. This thickness is much less than the thickness required to attenuate scattered radiation, which in turn is much less than the thickness required to attenuate the radiation due to Iridium-192 source. 5. Conclusion Based on the calculation presented in Section 4 of this document, it is concluded that: 5 1 The wall thickness of Makmal 5 shall be equal to or more than 80.0 cm of concrete 5.2 The thickness of the door for Makmal 5 shall be equal to or more than 20.0 mm of lead 5.3. The thickness of ceiling for Makmal 5 shall be equal to or more than 70.0 cm of concrete. 5.4 Plan view of the exposure room is presented in Fig.5 5.5. The thickness of labyrinth structure may be taken arbitrarily. Such a structure is meant to avoid the primary beam from reaching the door.

ISSUE DATE: 1/9/96 PAGE: 12 Wall thickness = 80 cm, ceiling thickness = 70 cm and lead door thickness = 20 mm. Figure 5: Plan View of The Exposure Room

ISSUE DATE: 1/9/96 PAGE: 13 6. Condition of Usage The following conditions are applied for the use of this exposure room: 6.1 The room may be used for both x- and gamma radiography purposes. 6.2 Under no circumstances that both x- and gamma radiography will be executed in this room simultaneously. 6.3 Spaces sorrounding this room is defined as clean area, thus accessible to member of public. 6.4 While in operation, the distance between the iridium source/x-ray focal point and the wall shall not be less than 1 meter. 6.5 While in operation, the distance between the iridium source/x-ray focal point and the ceiling shall not be less than 3 meters. 6.6 While in operation, the primary beam of the x-ray machine shall always be directed to the floor 6.7 Concrete used for the construction shall have a minimum density of 2.35g/cc. 6 8 Lead used for door construction shall have a minimum density of 1 1.35g/cc.

-77 W7

II 0 0 0 ii ill :> II ' ';' " >: ill IP fl'if i! it i ill! > ill 1 TIP Ml i! i!!

"db 111 p.i Y 40Q 5Cmm i C.I pipe slee 1 to detail e. ij R.C. WALL ^50" x" 75G x 900 depth refer to engr's detaii FO C3 WO FFL 57.75! IC..WALI, ;!<!!;!H " *_. <" J iltlllill X IF DARKROOM A/C C3 WO existing ground oeam to oe removea 25Grnm thk- brickwall with plaster externally 50mm 0 C.J pipe sleeve to aetaii :c/t -control panel motorised lead sliding doo D15l ^ knur's detail 1 J< 24 CORRIDOR F5 Ci WO (?]) >