How Does Temperature Affect Selectivity?

Similar documents
Relating Analyte Properties to HPLC Column Selectivity on the road to Nirvana

Automatization for development of HPLC methods

Strategy for Improving HPLC

How to Troubleshoot a Failed System Suitability Test

Introduction. Chapter 1. Learning Objectives

Basic Principles for Purification Using Supercritical Fluid Chromatography

Remember - Ions are more soluble in water than in organic solvents. - Neutrals are more soluble in organic solvents than in water.

Thomas Jupille, Lloyd Snyder, LC Resources Inc., Walnut Creek, California, USA, and Imre Molnar, Molnar Institut, Berlin, Germany.

Journal of Chromatography A

Mobile-Phase Cleanup Using Solid-Phase Extraction Disks

Important Guidelines for Optimizing Speed and Sensitivity in Small-Molecule LC UV and LC MS

Fast Screening Methods for Steroids by HPLC with Agilent Poroshell 120 Columns

Critical Pairs in Column Chromatography: A Primer for Pharmaceutical Method Validation

Theory and Instrumentation of GC. Chromatographic Parameters

Stability of Silica-Based, Monofunctional C 18 Bonded- Phase Column Packing for HPLC at High ph

CHAPTER 6 GAS CHROMATOGRAPHY

Volatile organic compounds (VOCs):

Chapter 31 Gas Chromatography. Carrier Gas System

Hypersil BDS Columns TG 01-05

Computer-Assisted Optimization of Reversed-Phase HPLC Isocratic Separations of Neutral Compounds

Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity

Fall 2012 Due In Class Friday, Oct. 19. Complete the following on separate paper. Show your work and clearly identify your answers.

Comparison of different aqueous mobile phase HPLC techniques

"Theory and Practice of High Speed Chromatography for Bioanalysis" Stuart Coleman March 20, 2007

Chromatography Modelling in High Performance Liquid Chromatography Method Development

LECTURE 2. Advanced Separation Science Techniques Present and Future Separation Tools

Hplc Lc Ms And Gc Method Development And Validation Guideline For Academic And Industrial Scientists Involved In Method Development And Validation

Hplc Lc Ms And Gc Method Development And Validation Guideline For Academic And Industrial Scientists Involved In Method Development And Validation

Pittcon P

Automating Method Development with an HPLC System Optimized for Scouting of Columns and Eluents

Varian Galaxie Chromatography Data System for Preparative HPLC

Advanced HPLC Method Development Using Quality by Design

Analytical Technologies in Biotechnology Dr. Ashwani K. Sharma Department of Biotechnology Indian Institute of Technology, Roorkee

Value of Eclipse Plus C18 and ph Selectivity to Analyze Amine-Containing Drugs

COMPARISON GUIDE. to C18 Reversed Phase HPLC Columns. Comparison Data on 60 Commonly Used C18 Phases. Stationary Phase Specifications

Live Webinar : How to be more Successful with your ACQUITY QDa Detector?

The Effects of Carrier Gas Viscosity and Diffusion on Column Efficiency in Capillary Gas Chromatography

Our Expanding Understanding and Use of Reversed-Phase Column Selectivity

Easy Method Transfer from HPLC to RSLC with the Dionex Method Speed-Up Calculator

We don t have anything against mass spectrometry. We just think it s time for a worthy alternative.

Method Development with Modern HPLC Phases

Luna 2.5 µm C18(2)-HST. Advantages of 2.5 µm for increasing the speed of analysis while maintaining high efficiency

Exceptional Selectivity of Agilent ZORBAX Eclipse Plus Phenyl-Hexyl Columns to Separate Estrogens

Chemistry Instrumental Analysis Lecture 28. Chem 4631

Modeling of HPLC Methods Using QbD Principles in HPLC

DEVELOPMENT OF HPLC METHOD FOR ANALYSIS OF NITRITE AND NITRATE IN VEGETABLE

penta-hilic UHPLC COLUMNS

Title Experiment 7: Gas Chromatography and Mass Spectrometry: Fuel Analysis

CHIRAL SEPARATION USING THIN LAYER CHROMATOGRAPHY

ASEAN GUIDELINES FOR VALIDATION OF ANALYTICAL PROCEDURES

Introduction to Chromatographic Separations

penta-hilic UHPLC COLUMNS

Analysis of Beer by Comprehensive 2D-LC with the Agilent 1290 Infinity 2D-LC system

Validated HPLC Methods

Chemistry Gas Chromatography: Separation of Volatile Organics

Journal of Chromatography A, 1016 (2003)

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW

Gas Chromatography. A schematic diagram of a gas chromatograph

Course goals: Course goals: Lecture 1 A brief introduction to chromatography. AM Quality parameters and optimization in Chromatography

The Retention Behavior of Reversed-Phase HPLC Columns with 100% Aqueous Mobile Phase

Solid Phase Extraction Method Development Tips and Tricks

Chromatography and other Separation Methods

HPLC method development using alternative selectivities

Journal of Chromatography A

Liquid storage: Holds the solvent which is going to act as the mobile phase. Pump: Pushes the solvent through to the column at high pressure.

A Strategy for an Unknown Screening Approach on Environmental Samples Using HRAM Mass Spectrometry

Ion Chromatography (IC)

Gas Chromatography. 1. Experiment Category: 2. Experiment Name: 3. Date and Issue number: 4. Instructor Name: 5. Institution: Ain Shams University

Use of DryLab for Simulation of TLC Separation and Method Transfer from TLC to HPLC

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION

Fusion QbD and the Perfect Storm of Technologies Driving QbDaligned LC Method Development

Chromatographic Analysis

1.7 m Fortis UHPLC Columns

Department of Chemistry University of Texas at Austin

New 5-micron HALO-5 columns based on Fused- Core particle technology boost the performance of HPLC. Compared to other HPLC columns, HALO-5 columns

Introduction to Capillary GC

LEARNING OBJECTIVES CHEM 212: SEPARATION SCIENCE CHROMATOGRAPHY UNIT. Thomas Wenzel, Bates College. In-class Problem Set Extraction.

An Introductions to Advanced GPC Solutions

LC and LC/MS Column Selection Flow Chart

Tips & Tricks GPC/SEC: Quantify and Get More Than Molar Mass Averages

Analytical Chemistry

The Theory of HPLC. Ion Pair Chromatography

Reversed Phase Solvents

Evaluation of a New HPLC, a New Tandem MS and a New Data Processing Software for General Clinical Use

A Study of Stability, Robustness and Time Efficiency of a New HPLC and a New Tandem MS

Chromatographic Separation

Routine MS Detection for USP Chromatographic Methods

LC Columns with Liquid Separation Cell Technology

Automated LC Method Development: Fundamentals and Columns, Hardware, and Software

Acclaim Mixed-Mode WCX-1

Introduction to Chromatography

Fast Separation of Vastly Different Compounds by Isocratic HPLC

HPLC Background Chem 250 F 2008 Page 1 of 24

CHEM Experiment Five Gas Chromatographic Analysis Of A Phenolic Extract. Objectives:

Comparison Guide to C18 Reversed Phase HPLC Columns

Chapter 23 Introduction to Analytical Separations

Chapter 26. An Introduction to Chromatographic Separations. Chromatography

What is Chromatography?

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer

This lab will be conducted in groups but the lab report must be completed and submitted individually.

Transcription:

LCGC - How Does Temperature Affect Selectivity? http://www.lcgcmag.com/lcgc/content/printcontentpopup.jsp?id=429506 Página 1 de 3 26/05/2007 How Does Temperature Affect Selectivity? May 1, 2007 By: John W. Dolan LCGC North America Column temperature plays an important role in controlling peak spacing (selectivity) in reversed-phase liquid chromatography (LC) separations. Temperature has long been known to affect retention time, and more recently, its use in adjusting selectivity has gained popularity (see reference 1 for a review of temperature selectivity). In preparation of a paper (2) for the most recent Pittsburgh Conference, I had an opportunity to reexamine some data that compare temperature selectivity with other variables used to control selectivity in LC separation. This month's installment of "LC Troubleshooting" examines temperature selectivity and its relationship to ph selectivity. Selectivity and Temperature One common way to plot changes in peak spacing with a change in a John W. Dolan variable is to use a resolution map. This is illustrated in Figure 1a for the effect of temperature on resolution for a mixture of 11 weak acids and bases. The resolution map plots the resolution for the leastresolved pair of peaks in the separation for different column temperatures. The best resolution is seen for the high points on the plot, at approximately 34 C and 41 C, whereas two peaks overlap completely whenever the plot dips to the zero resolution baseline. The resolution at 34 C is illustrated in Figure 2a, where all 11 peaks are resolved from each other. Moving to lower temperatures causes peaks 5 and 6 (4-n-butyl benzoic acid and 4-n-hexyl aniline) to move together; higher temperatures cause peaks 3 and 4 (4-n-pentyl Figure 1 aniline and diflunisal) to move together 34 C is the balance point where both peak pairs have the same resolution. In a similar manner, the resolution at 41 C (Figure 3a) between peaks 6 and 7 (4-n-hexyl aniline and diclofenac acid) is balanced with that of peaks 1 and 2 (2-phenyl pyridine and ketoprofen).

LCGC - How Does Temperature Affect Selectivity? http://www.lcgcmag.com/lcgc/content/printcontentpopup.jsp?id=429506 Página 2 de 3 26/05/2007 Resolution maps are powerful tools for the quick identification of resolution maxima and can be useful to help estimate method robustness to changes in the variable under consideration. Such maps are key features of resolution modeling software, such as DryLab (Molnar Institute, Berlin, Germany). Resolution maps that have many peak reversals (dips to zero resolution), such as the one in Figure 1a, are more common with samples containing ionic compounds than for neutral compounds. Selectivity and ph When I examined the resolution map for temperature selectivity for the mixture of acids and bases used here, it struck me that it looked very much like resolution maps that I see for ph as the variable. So I plotted a map of resolution versus ph for the same sample, based upon the data of references 3 and 4. In Figure 1b, I have shown just a portion of the ph map normalized to approximately the same layout as the section of the temperature map of Figure 1a. They are strikingly similar. They have the same peaks forming the least resolved pairs in each region of the resolution map, and the overall maximum resolution is approximately the same in both cases. So just as we had maxima at 34 C and 41 C in Figure 1a, we have corresponding maxima at ph 2.785 and 2.910 in Figure 1b. Compare the chromatograms for these temperature and ph conditions in Figures 2a and 2b (34 C versus ph 2.785) and 3a and 3b (41 C versus ph 2.910). For each pair of chromatograms, the retention order is identical and the peak spacing is almost the same. Also note that the higher temperature of the 41 C run reduced the retention times of all the peaks, as expected for an increase in temperature. Figure 2 But Is It Real? Resolution maps represent predicted separations based upon input data from two (or more) "calibration" runs. In the present case, the temperature map was based upon a run at 35 C and one at 45 C, with both runs at ph 2.80. The ph map was made at ph 2.80 and 3.00 for 35 C. You might suspect that once one interpolates or extrapolates new separations at points other than the input data points, errors are likely. Yes, this is true, and the "garbage-in-garbage-out" axiom of computer programs applies here, as well. However, in my experience, if the data are gathered under carefully controlled conditions (these were), the predictive accuracy is in the ±1 5% region. The comparative results of Figures 2a, 2b, 3a, and 3b certainly support this. But these are predicted separations and you say, "Show me the beef" for real runs. We can compare the results of real experiments by comparing the input runs used to generate the resolution maps of Figure 1. In both cases, the input data were suboptimal on the right side of the two resolution maxima in Figures 1a and 1b. Both maps used a common point of 35 C and ph 2.80, as shown in Figure 2c. A 45 C, ph 2.80 run was used as a second point to generate the resolution map of Figure 1a. Similarly, a 35 C, ph 3.00 run was used for the second point of the resolution map of Figure 1b. These two runs are shown in Figures 3c and 3d, respectively. They are not a perfect match. First, we notice that the last peak of Figure 3c is eluted at approximately 10 min, whereas the last peak of Figure 3d is closer to 12 min. Remember that the rule of thumb for a change in retention with temperature says that a 1 C increase in temperature will decrease retention by approximately 2%. So a 10 C increase in temperature reduced the retention time by approximately 20%, as expected. Second, note that the first two peaks in Figure 3c can be distinguished as a doublet, whereas they are merged into a single peak in Figure 3d. This agrees Figure 3 with the resolution map data, too note that the 45 C point in Figure 1a is about halfway up the side of the resolution plot with a maximum at 41 C, whereas the ph 3.00 point is near the bottom of the corresponding plot of Figure 1b. So What's Happening? One more way to look at the data is shown in Figure 4. Figure 4a is the reference run at 35 C and ph 2.80 (same as Figure 2c). When the temperature was increased to 45 C, the run of Figure 4b resulted (same as Figure 3c). Note that the dotted lines indicate that there were three peak reversals that occurred with the temperature change. Figure 4c shows the results for a change in ph from 2.80 to 3.00, both at 35 C (same as Figure 3d). The dotted lines show that the peak order for the 45 C and ph 3.00 runs is identical. That is, the exact same crossovers occurred when going from 35 C to 45 C as when changing from ph 2.80 to ph 3.00. These data strongly suggest that a change in column temperature has exactly the

LCGC - How Does Temperature Affect Selectivity? http://www.lcgcmag.com/lcgc/content/printcontentpopup.jsp?id=429506 Página 3 de 3 26/05/2007 same effect as a change in ph (at least for this sample). If we think about this, Figure 4 though, it is not too surprising we know that buffer ph changes with temperature, that sample ionization changes with temperature, and that the ionization of the silanols on the column changes with temperature. Some combination of these changes is likely in the present case. However, these results are more than a novelty they have very practical implications. Note that it takes a 10 C change in temperature to make the same change as a 0.2-unit change in ph. If you use the ph adjustment technique of titrating the buffer to a desired ph with a ph meter, the normal variation of the actual ph is in the range of ±0.1 ph unit. It is much easier to control the temperature within a degree or two than it is to control the ph within <0.1 ph units. Furthermore, we can "tweak" the temperature a degree or two to adjust a separation much easier than adjusting the ph of the buffer. What are the take-home lessons? First, temperature is a powerful variable to use to adjust selectivity when ionic compounds are present, so it should be considered when developing a method. Second, because temperature is such a powerful variable, it is very important to use temperature control for your column and to use a buffered mobile phase if you want to obtain reproducible separations with ionic compounds. Finally, a small 1 2 C change in temperature might be sufficient to make minor adjustments to the method to enhance the separation of a pair of peaks when a small error in buffer preparation was made or column aging causes a reduction in resolution. JohnW. Dolan "LC Troubleshooting" Editor John W. Dolan is Vice-President of LC Resources, Walnut Creek, California; and a member of LCGC's editorial advisory board. Direct correspondence about this column to "LC Troubleshooting," LCGC, Woodbridge Corporate Plaza, 485 Route 1 South, Building F, First Floor, Iselin, NJ 08830, e-mail John.Dolan@LCResources.com For an ongoing discussion of LC trouble-shooting with John Dolan and other chromatographers, visit the Chromatography Forum discussion group at http://www.chromforum.com. References (1) J.W. Dolan, J. Chromatogr. A 965, 195 205 (2002). (2) J.W. Dolan, Pittcon 2007, paper 890-2. A Request for Readers (3) N.S. Wilson, M.D. Nelson, J.W. Dolan, L.R. Snyder, R.G. Wolcott, and P.W. Carr, J. Chromatogr. A 961, 171 193 (2002). (4) N.S. Wilson, M.D. Nelson, J.W. Dolan, L.R. Snyder, and P.W. Carr, J. Chromatogr. A 961, 195 215 (2002).