Study on Effective Particle Diameters and Coolability of Particulate Beds Packed with Irregular Multi-size Particles

Similar documents
VALIDATION OF THE MEWA CODE AGSINST POMECO-HT EXPERIMENTS AND COOLABILITY ANALYSIS OF STRATIFIED DEBRIS BEDS

Onset of Flow Instability in a Rectangular Channel Under Transversely Uniform and Non-uniform Heating

CHAPTER 5 CONVECTIVE HEAT TRANSFER COEFFICIENT

SIMULATION OF FLOW IN A RADIAL FLOW FIXED BED REACTOR (RFBR)

Fig.8-1 Scheme of the fluidization column

Experimental and Numerical Investigation on Thermal Behavior of PCM in Storage Tank

Principles of Food and Bioprocess Engineering (FS 231) Problems on Heat Transfer

HEAT TRANSFER CAPABILITY OF A THERMOSYPHON HEAT TRANSPORT DEVICE WITH EXPERIMENTAL AND CFD STUDIES

Analysis of the Cooling Design in Electrical Transformer

Coupled CFD-STH analysis of liquid metal flows: STAR-CCM+ - RELAP5

Lectures on Applied Reactor Technology and Nuclear Power Safety. Lecture No 6

Effective Momentum and Heat Flux Models for Simulation of Stratification and Mixing in a Large Pool of Water. Hua Li, Walter Villanueva, Pavel Kudinov

Experiment (4): Flow measurement

Solar Flat Plate Thermal Collector

Minhhung Doan, Thanhtrung Dang

Exergy Analysis of Solar Air Collector Having W Shaped Artificial Roughness

Simultaneous heat and mass transfer studies in drying ammonium chloride in a batch-fluidized bed dryer

EXPERIMENTAL INVESTIGATION OF DEBRIS BED AGGLOMERATION AND PARTICLE SIZE DISTRIBUTION USING WO3-ZRO2 MELT

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

AN EXPERIMENTAL INVESTIGATION OF BOILING HEAT CONVECTION WITH RADIAL FLOW IN A FRACTURE

FLOW BOILING HEAT-TRANSFER IN PLATE MICRO- CHANNEL HEAT SINK

ENGINEERING OF NUCLEAR REACTORS

FLOW CHARACTERIZATION WITHIN A SPHERE-PACKED BED USING PIV MEASUREMENT

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

Boiling Heat Transfer and Pressure Drop of R1234ze(E) inside a Small-Diameter 2.5 mm Microfin Tube

Experiment B6 Thermal Properties of Materials Procedure

THE EXPERIMENTAL STUDY OF THE EFFECT OF ADDING HIGH-MOLECULAR POLYMERS ON HEAT TRANSFER CHARACTERISTICS OF NANOFLUIDS

Applied Fluid Mechanics

NATURAL CONVECTION HEAT TRANSFER CHARACTERISTICS OF KUR FUEL ASSEMBLY DURING LOSS OF COOLANT ACCIDENT

Applied Fluid Mechanics

ENGINEERING OF NUCLEAR REACTORS. Fall December 17, 2002 OPEN BOOK FINAL EXAM 3 HOURS

Sensitivity Estimation of Permanent Magnet Flowmeter

Topic 8: Flow in Packed Beds

DEVELOPMENT OF TALL-3D TEST MATRIX FOR APROS CODE VALIDATION

QUALIFICATION OF A CFD CODE FOR REACTOR APPLICATIONS

DETERMINATION OF R134A S CONVECTIVE HEAT TRANSFER COEFFICIENT IN HORIZONTAL EVAPORATORS HAVING SMOOTH AND CORRUGATED TUBES

If there is convective heat transfer from outer surface to fluid maintained at T W.

ME 331 Homework Assignment #6

USING MULTI-WALL CARBON NANOTUBE (MWCNT) BASED NANOFLUID IN THE HEAT PIPE TO GET BETTER THERMAL PERFORMANCE *

TWO-PHASE FLOW FRICTIONAL PRESSURE DROP OF FC-14 IN HORIZONTAL TUBES

A First Course on Kinetics and Reaction Engineering Unit D and 3-D Tubular Reactor Models

Experimental investigation on up-flow boiling of R1234yf in aluminum multi-port extruded tubes

Experimental Study of Convective Heat Transfer and Thermal Performance in the Heat-Sink Channel with Various Geometrical Configurations Fins

Coolant Flow and Heat Transfer in PBMR Core With CFD

ME332 FLUID MECHANICS LABORATORY (PART II)

Pin Fin Lab Report Example. Names. ME331 Lab

International Journal of Heat and Mass Transfer

FORCE FED BOILING AND CONDENSATION FOR HIGH HEAT FLUX APPLICATIONS

CENG 501 Examination Problem: Estimation of Viscosity with a Falling - Cylinder Viscometer

Evaporative Heat Transfer in a Capillary Structure Heated by a Grooved Block

Heat Transfer Predictions for Carbon Dioxide in Boiling Through Fundamental Modelling Implementing a Combination of Nusselt Number Correlations

CUNY Academic Works. City University of New York (CUNY) Joseph Kreynin CUNY City College. Recommended Citation

1. Mark the correct statement(s)

EXPERIMENT NO. 4 CALIBRATION OF AN ORIFICE PLATE FLOWMETER MECHANICAL ENGINEERING DEPARTMENT KING SAUD UNIVERSITY RIYADH

MAE 598 Project #1 Jeremiah Dwight

M. R. Gartia Reactor Engineering Division Bhabha Atomic Research Centre, Trombay Mumbai P. K. Vijayan.

University of Rome Tor Vergata

NUMERICAL AND EXPERIMENTAL INVESTIGATION OF THE TEMPERATURE DISTRIBUTION INSIDE OIL-COOLED TRANSFORMER WINDINGS

Department of Engineering and System Science, National Tsing Hua University,

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

ATLAS Facility Description Report

Chapter 11: Heat Exchangers. Dr Ali Jawarneh Department of Mechanical Engineering Hashemite University

4.1 Derivation and Boundary Conditions for Non-Nipped Interfaces

Theoretical and Experimental Studies on Transient Heat Transfer for Forced Convection Flow of Helium Gas over a Horizontal Cylinder

CHAPTER 4 RESULTS AND DISCUSSION

EVAPORATIVE CO 2 HEAT TRANSFER MEASUREMENTS FOR COOLING SYSTEMS OF PARTICLE PHYSICS DETECTORS

A Study on Hydraulic Resistance of Porous Media Approach for CANDU-6 Moderator Analysis

SSRG International Journal of Mechanical Engineering ( SSRG IJME ) Volume 2 Issue 5 May 2015

Experiment 1. Measurement of Thermal Conductivity of a Metal (Brass) Bar

Paper No. : 04 Paper Title: Unit Operations in Food Processing Module- 18: Circulation of fluids through porous bed

This is an author-deposited version published in: Eprints ID : 17555

Finite Element Analysis of the Heat Transfer in a Copper Mould during Continuous Casting of Steel Slabs. 14 May 2005

Improvement of Critical Heat Flux Performance by Wire Spacer

Analysis and interpretation of the LIVE-L6 experiment

CHAPTER 3 SHELL AND TUBE HEAT EXCHANGER

Two-Phase Refrigerant Distribution in a Micro- Channel Manifold

Visualization of Natural Convection in Enclosure. Filled with Porous Medium by Sinusoidally. Temperature on the One Side

ME 402 GRADUATE PROJECT REPORT ACTIVE BATTERY COOLING SYSTEM FOR ALL-ELECTRIC VEHICLES JINGWEI ZHU

Oscillating Flow Characteristics of a Regenerator under Low Temperature Conditions

GRANULAR PRESSURE MEASUREMENT IN FLUIDIZED BEDS

Experimental study of the convective heat transfer coefficient in a packed bed at low Reynolds numbers

UNIVERSITY OF WATERLOO. ECE 309 Thermodynamics and Heat Transfer. Final Examination Spring 1997

Chapter 10: Steady Heat Conduction

TURBULENT CONVECTION EXPERIMENT TO SUPPORT IVR STRATEGY

EXPERIMENTAL ANALYSIS OF R-134a FLOW CONDENSATION IN A SMOOTH TUBE

ENERGY DISTRIBUTION ANALYSIS IN A LOW HEAD FRANCIS TURBINE DURING THERMODYNAMIC EFFICIENCY MEASUREMENTS

Process Control & Design

ECE309 INTRODUCTION TO THERMODYNAMICS & HEAT TRANSFER. 3 August 2004

High-Pressure Volumetric Analyzer

EXPERIMENTAL STUDY OF THE CONVECTIVE HEAT TRANSFER COEFFICIENT IN A PACKED BED AT LOW REYNOLDS NUMBERS

Application of an ultrasonic velocity profile monitor in a hydraulic laboratory

Recap: Introduction 12/1/2015. EVE 402 Air Pollution Generation and Control. Adsorption

INVESTIGATION OF VAPOR GENERATION INTO CAPILLARY STRUCTURES OF MINIATURE LOOP HEAT PIPES

STANFORD GEOTHERMAL PROGRAM QUARTERLY REPORT

3D Simulation of the Plunger Cooling during the Hollow Glass Forming Process Model, Validation and Results

FVBSS fixed volume bottle

THE PRESSURE-TIME MEASUREMENTS PROJECT AT LTU AND NTNU

Experimental Studies of Active Temperature Control in Solid Breeder Blankets

Experimental Study on Port to Channel Flow Distribution of Plate Heat Exchangers

Transcription:

NKS-288 ISBN 978-87-7893-363-8 Study on Effective Particle Diameters and Coolability of Particulate Beds Packed with Irregular Multi-size Particles Sachin Thakre, Weimin Ma, Pavel Kudinov, Sevostian Bechta Royal Institute of Technology, KTH, Sweden August 2013

Abstract One of the key questions in severe accident research is the coolability of the debris bed, i.e., whether decay heat can be completely removed by the coolant flow into the debris bed. Extensive experimental and analytical work has been done to substantiate the coolability research. Most of the available experimental data is related to the beds packed with single size (mostly spherical) particles, and less data is available for multi-size/irregular-shape particles. There are several analytical models available, which rely on the mean particle diameter and porosity of the bed in their predictions. Two different types of particles were used to investigate coolability of particulate beds at VTT, Finland. The first type is irregularshape Aluminum Oxide gravel particles whose sizes vary from 0.25 mm to 10 mm, which were employed in the STYX experiment programme (2001-2008). The second type is spherical beads of Zirconium silicate whose sizes vary between 0.8 mm to 1 mm, which were used in the COOLOCE tests (Takasuo et al., 2012) to study the effect of multi-dimensional flooding on coolability. In the present work, the two types of particles are used in the POMECO-FL and POMECO-HT test facility to obtain their effective particle diameters and dryout heat flux of the beds, respectively. The main idea is to check how the heaters orientations (vertical in COOLOCE vs. horizontal in POMECO-HT) and diameters (6 mm in COOLOCE vs. 3 mm in POMECO-HT) affect the coolability (dryout heat flux) of the test beds. The tests carried out on the POMECO-FL facility using a bed packed with aluminum oxide gravel particles show the effective particle diameter of the gravel particles is 0.65 mm, by which the frictional pressure gradient can be predicted by the Ergun equation. After the water superficial velocity is higher than 0.0025 m/s, the pressure gradient is underestimated. The effective particle diameter of the zirconium particles is found as 0.8 mm. The dryout heat flux is measured on the POMECO-HT facility using particulate beds packed with the same particles as in POMECO-FL. The dryout heat flux of the bed with aluminum oxide gravels under top flooding is found to be close to the prediction of the Lipinski model. The dryout heat flux increases by 51% when applying a 12-mm size downcomer. The dryout heat flux of the bed with zirconium particles test lies between the values predicted by the Reed model and Lipinski model. The use of the 12-mm size downcomer increases dryout heat flux by 16%. Key words Debris bed coolability, Effective particle diameter, Particulate bed, Dryout heat flux NKS-288 ISBN 978-87-7893-363-8 Electronic report, August 2013 NKS Secretariat P.O. Box 49 DK - 4000 Roskilde, Denmark Phone +45 4677 4041 www.nks.org e-mail nks@nks.org

NKS-DECOSE Report-2/2012 2013-06-17 APRI-8, NKS-DECOSE Report 2/2012 Study on Effective Particle Diameters and Coolability of Particulate Beds Packed with Irregular Multi-size Particles Sachin Thakre, Weimin Ma, Pavel Kudinov and Sevostian Bechta Division of Nuclear Power Safety Royal Institute of Technology (KTH) 10691 Stockholm, Sweden June 17, 2013 Stockholm

NKS-DECOSE Report-2/2012 2013-06-17 2

NKS-DECOSE Report-2/2012 2013-06-17 Contents 1. Introduction... 5 2. Effective particle diameter... 5 2.1 POMECO-FL test facility... 5 2.2 Qualification of the facility... 6 2.3 Test particulate beds... 7 3. Dryout heat flux... 10 3.1 POMECO-HT test facility... 10 3.2 Qualification of the POMECO-HT facility... 12 3.3 Test particulate beds... 12 4. Concluding remarks... 15 5. References... 16 3

NKS-DECOSE Report-2/2012 2013-06-17 4

NKS-DECOSE Report-2/2012 2013-06-17 1. Introduction One of the key questions in severe accident research is the coolability of the particulate bed, i.e., whether decay heat can be completely removed by the coolant ingress into the debris bed. Extensive experimental and analytical work has been done to substantiate the coolability research. Most of the available experimental data is related to the beds packed with single size (mostly spherical) particles, and less data is available for multi-size/irregular-shape particles. There are several analytical models available, which rely on the mean particle diameter and porosity of the bed in their predictions. Two different types of particles were used to investigate coolability of particulate beds at VTT, Finland. The first type is irregular-shape Aluminum Oxide gravel particles whose sizes vary from 0.25 mm to 10 mm, which were employed in the STYX experiment programme (2001-2008). The second type is spherical beads of Zirconium silicate whose sizes vary between 0.8 mm to 1 mm, which were used in the COOLOCE tests (Takasuo et al., 2012) to study the effect of multi-dimensional flooding on coolability. In the present work, the two types of particles are used in the POMECO-FL and POMECO- HT test facility to obtain their effective particle diameters and dryout heat flux of the beds, respectively. The main idea is to check how the heaters orientations (vertical in COOLOCE vs. horizontal in POMECO-HT) and diameters (6 mm in COOLOCE vs. 3 mm in POMECO- HT) affect the coolability (dryout heat flux) of the test beds. 2. Effective particle diameter 2.1 POMECO-FL test facility The experiment is carried out on the POMECO-FL test facility, as illustrated in Fig. 2, which is basically an adiabatic water/air single and two-phase flow loop for porous media. Major components of the test facility are made of transparent Plexiglas to facilitate visual observation. The test section accommodating the particulate bed is made of a Plexiglas pipe with the inside diameter of 90 mm and the height of 635 mm. Four annular chambers for pressure tapping are designed to surround the pipe at different levels, with radial holes (0.5 mm in diameter) uniformly distributed as opening from the bed to the annular chambers. The chambers not only provide an average pressure reading over the entire circumference of each tapping point, but also prevent gas and particles from entering the impulse lines of pressure transducers. At both the inlet and the outlet of the test section, two pieces of stainless steel wire mesh are applied between the flanges to support the bed from below and prevent the particles from leaving the bed. Air is supplied from the bottom and flows up through the packed bed, but water can be supplied from either the bottom or the top for a bottom-fed (cocurrent flow) or a top-flooding (counter-current flow) bed. 5

NKS-DECOSE Report-2/2012 2013-06-17 Fig. 1. Schematic of POMECO-FL facility Two Rosement-3051 differential pressure transmitters with high accuracy are mounted on the test section to measure entire and half pressures drops, respectively, of single- or two-phase flow through the bed. Valve manifolds are used with the differential pressure transmitters to perform the block, equalizing and vent requirements of the transmitters. The flowrates of gas and water flows are measured by seven OMEGA flow meters with different measuring ranges. The pressure and temperature are monitored by using OMEGA pressure transducers and K-type thermocouples. The flow meters and pressure transducers were calibrated prior to experiment. A Data Acquisition System (DAS) is realized via National Instruments data acquisition products and a computer program written in LabView. The program collects the data from thermocouples, pressure transducers, flow meters (via manual input), and employs the indicators to show the numerical data and its graphical representation such as charts. 2.2 Qualification of the facility After the well-mixed particles are uniformly loaded into the test section, the fluid (air or water for single phase flow) is made to flow through the packed bed at low velocity until there is no change in bed height and in flow resistance, to make sure that the fluid floods the bed and has access to all the pores. For the pressure drop measurement, the impulse lines of the differential pressure transmitters are filled with single phase fluid by proper operation of the valve manifolds, so that the effect of gravity on pressure drop reading can be excluded. Prior to start measurements, the facility is running for no less than half an hour to establish steady state conditions throughout the system. After the steady-state data are recorded by the data acquisition system, changing the operational parameters (e.g., the flowrates), the procedure is repeated. 6

dp/dz (Pa/m) NKS-DECOSE Report-2/2012 2013-06-17 In addition to the calibration of instrumentation, the test facility and its measurement system were also qualified by measurements of single-phase flow through three beds packed with single-size glass spheres of diameter 3mm. The porosity of the bed is 0.366. Water was employed as working fluid. The measured pressure gradients were then compared with those predicted by the Ergun equation, whose predictions are generally accepted for packed beds of spheres with satisfactory accuracy (Nemec and Levec, 2005). Fig. 2 shows the comparisons between the measured values of the experiment and the predicted values of the Ergun equation, where triangle symbols represent experimental data and the solid curves the predicted ones. The correct operation of the facility and accuracy of the instrumentation can be justified on the basis that measured and calculated results agree excellently in case of a well-known problem. 500 450 400 350 300 250 200 150 100 50 0 experiment Ergun eq. 0 0.0005 0.001 0.0015 0.002 0.0025 0.003 0.0035 Superficial velocity (m/s) Fig. 2. Frictional pressure gradient of water flow in the bed packed with 3 mm single size spheres 2.3 Test particulate beds In the present single phase study, the experiment is carried out on POMECO-FL facility using Bed-1 and Bed-2. The pictures of particles used in Bed-1 and Bed-2 are shown in fig. 3. The mass distribution of Alumina gravels was determined by sieving the particles using different size sieves and it is compared (fig. 4) with the distribution used in STYX experiments. The provided density of the particles is 3930 kg/m 3, but in order to maintain the accuracy in the calculations, the density has been recalculated using one of the fundamental methods. The volume measurement beaker is used and the volume of the known mass of the particles is measured by pouring the particles in a beaker containing known volume of water. Taking multiple readings the average density is calculated. Similar process is applied for Bed-2 particles and the density has been deduced. The details of the particulate beds are provided in table 1. Water is employed as a working fluid. The experiment procedure is followed similar to that explained earlier. 7

Cumulative mass (%) NKS-DECOSE Report-2/2012 2013-06-17 Table 1 Details of the beds. Bed Particle type Density (kg/m 3 ) Bed porosity Particle diameter (mm) Bed-1 Alumina gravels 3900 0.408 0.25-10 Bed-2 Zirconium silicate spheres 4230 0.399 0.8-1 a) b) Fig. 3. Particles used in experiments (a. used in Bed-1and, b. used in Bed-2) 120 100 80 60 40 used destribution STYX distribution 20 0 0 2 4 6 8 10 12 Particle size (mm) Fig. 4 Alumina gravels particle distribution (compared with Lindholm et al., 2006) The effective particle diameter of the particles is calculated using frictional pressure gradients obtained from experiment and the Ergun equation. 2 1 2 dp 2 1 J J 150 J 1.75 J Eq. (1) 2 3 3 dz K d d 8

dp/dz (Pa/m) NKS-DECOSE Report-2/2012 2013-06-17 Where, dp/dz is the pressure gradient along the height of the bed. The parameters K and η are called permeability and passability, respectively. Moreover, in the expression of Eq.(1), 150 and 1.75 are called the Ergun constants, and d is the diameter of particles, ε is the bed porosity, μ is the dynamic viscosity of fluid, ρ is the density and J is the superficial velocity of fluid. The porosity of the Bed-1 is measured as 0.408. The shape factor is taken as 1. Substituting values in Eq. (1), the effective particle diameter (d) is calculated and it is found as 0.65 mm. Similarly, the porosity and the effective particle diameter for the Bed-2 are found as 0.399 and 0.799 0.8 mm respectively. The measured pressured gradients are then compared with those calculated by Ergun equation. Figure 5 shows the comparison between experimental data and the predicted values using Ergun equation for Bed-1. It illustrates that the experimental frictional pressure gradient values are closer to predicted values till 0.0025 m/s water velocity and, thereafter it is slightly underestimated by the Ergun equation. Figure 6 shows the variation of the experimental frictional pressure gradient with respect to superficial velocity. The values are closely matching with the Ergun equation. Though it is specified that the particles size varies between 0.8 to 1 mm, the effective particle diameter is found as 0.8 mm, which shows that the porosity and the characteristics of the Bed-2 is equivalent to that of the bed filled with 0.8 mm uniform size particles. 10000 9000 8000 7000 6000 5000 4000 3000 2000 1000 0 Ergun eqn experiment 0 0.001 0.002 0.003 0.004 0.005 Superficial velocity (m/s) Fig. 5. Frictional pressure gradients of water flow in the Bed-1. 9

dp/dz (Pa/m) NKS-DECOSE Report-2/2012 2013-06-17 20000 18000 16000 14000 12000 10000 8000 6000 4000 2000 0 experiment Ergun eq. 0 0.002 0.004 0.006 0.008 0.01 0.012 0.014 Superficial velocity (m/s) 3. Dryout heat flux 3.1 POMECO-HT test facility Fig. 6. Frictional pressure gradients of water flow in the Bed-2. The POMECO-HT facility features a high heat flux up to 2.1 MW/m 2, which enables a sufficient internal power for particulate beds of various characteristics to reach dryout condition for both top-flooding and bottom-fed cases. 6 8 1 vapor 5 Out (bottom fed) 9 1000 DAS In (top flooding) 200 2 8 3 Downcomer 4 7 ΔP ΔP 620 In(bottom fed) 1-water tank, 2-water flowmeter, 3-particle bed, 4-heaters, 5-data acquisition system, 6-steam flowmeter, 7-pressure transducer, 8-thermocouples, 9-water level gauge Fig. 7 Schematic Diagram of POMECO-HT Facility 10

NKS-DECOSE Report-2/2012 2013-06-17 The schematic of the POMECO-HT facility is shown in Fig. 7, which consists of test section, water supply system, electrical heaters and their power supply system, instrumentation (thermocouples, flowmeters and pressure transducers) and data acquisition system (DAS). The test section for accommodating the particulate bed and heaters is a stainless steel vessel whose cross-sectional area is 200 mm 200 mm rectangular with the height of 620 mm. Over the test section is sitting a stainless steel water tank (200 mm 200 mm) which is 1000 mm tall and connected to the test section through flanges. A level meter is installed on the water tank to monitor the water level during the experiments. The test section and the water tank are well insulated. A total number of 120 electrical resistance heaters are uniformly distributed in the particulate bed with 15 vertical layers and each layer has 8 pcs heaters, as shown in Fig. 7. The average distance between the two adjacent heaters is about 38 mm in vertical direction and 25 mm in horizontal direction. The power rating of each heater is 700 W, so the maximum power capacity of facility is 84 kw. The particulate bed is also provided with 96 thermocouples installed at 16 vertical levels, each having 6 thermocouples at different locations of the cross-section. Basically, the thermocouple layer is 19 mm away from the heater layer. Moreover, 6 thermocouples are specially installed which are very close to the heaters in 6 different layers for monitoring the temperature of heaters. These thermocouples have the same direction with the heaters and are only 2 mm away from the heaters, and the measured location is near the center of the heaters. The diameter of each thermocouple is 1.5 mm with various lengths inserted in the bed, as shown in Fig.8b. While each heater has the diameter of 3 mm and the total length of 235 mm, with the heated part of 195 mm. So the heaters and thermocouples occupy about 0.7% in volume of the test section. (a) side view (b) top view Fig. 8 Distribution of Heaters and Thermocouples 11

-dp/dz (kpa/m) NKS-DECOSE Report-2/2012 2013-06-17 For the present experiments, the received particles amount is 10 liters, which is not enough to fill the total volume (24.4 liters) of the bed. Therefore, 0.01 m 3 of the total test section is utilized for the experiments. The numbers of heaters utilized are 48 and the maximum power capacity of the bed is 33.6 kw. 3.2 Qualification of the POMECO-HT facility Once the calibration of instrumentation is done, the test facility along with its measurement system is qualified by conducting a single-phase flow measurements through a bed packed with single-size of 1.5 mm diameter stainless steel spheres. Water is employed as a working fluid. The measured pressure gradients are compared with those predicted by the Ergun equation. Fig. 9 shows the comparisons between the measured data and the predicted values of the Ergun equation. The triangular symbols represent experimental data whereas the solid curves are predicted ones. A comparison shows a good agreement which ensured a quality of experimentation and instrumentation. 5 4 Ergun equation (1952) Experiment 3 2 1 0 0 1 2 3 4 5 6 J l (mm/s) Fig. 9 Pressure gradients of water flow in the bed packed with 1.5 mm stainless steel spheres 3.3 Test particulate beds In the POMECO-HT experiments, Bed-1 and Bed-2 are regarded (similar to POMECO-FL test beds) to Alumina gravels and Zirconium Silicate beads particles respectively. Initially, the test with Bed-1 is carried out to calculate the dryout heat flux in the bed. The bed is filled with 10 liters of Alumina gravel particles. The porosity of the bed is calculated as 0.35, from the filled volume, density of material and the weight of the bed. The top flooding test is initiated with supplying the hot water to the bed, followed by slowly heating the bed to bring the water to the completely saturated condition and also the uniform temperature across the bed. Thereafter, the power is increased in small steps and the time between each power step increment is at least 15 minutes. Near the expected dryout, the power increment step is further reduced and the time span is increased. The dryout is recognized by the sudden rise in the temperature anywhere in the bed, detected by the thermocouples. The dryout for the Bed-1 is 12

Dryout heat flux (kw/m 2 ) Dryout heat flux (kw/m 2 ) NKS-DECOSE Report-2/2012 2013-06-17 found at 3.59 kw power, which gives the dryout heat flux of 89.9 kw/m 2, under top flooding conditions. The location of dryout inception is found at 96 mm from the bottom which is in the lower half of the bed. Figure 10 shows the comparison of the dryout heat flux with different models. It illustrates that the dryout heat flux calculated from the experiment is slightly higher than those values predicted by the models. Among the comparison, the Lipinski model predicted dryout heat flux closer to the experimental value. 95 90 85 80 75 70 Reed Lipinski Hu_Theof Schulen_Muller Experiment Fig. 10 Comparison of the dryout heat flux in Bed-1 with various models under top flooding conditions In order to test the effect of downcomer on the dryout heat flux of Bed-1, 12 mm downcomer is installed in the test. The dryout heat flux is found at 135.75 kw/m 2. Figure 11 compares the dryout heat flux between top flooding and with the downcomer and it shows the 51% increment in the dryout heat flux using 12 mm downcomer. 160 140 120 100 51% 80 60 40 20 0 Top-flooding Downcomer-12 mm Fig. 11 Effect of downcomer on dryout heat flux in Bed-1 13

Dryout heat flux (kw/m 2 ) Dryout heat flux (kw/m2) NKS-DECOSE Report-2/2012 2013-06-17 Secondly, the Bed-2 (Zirconium Silicate beads) is prepared for the next test on POMECO-HT facility. Similar to Bed-1, the volume of Bed-2 is 10 liters. The porosity of the bed is calculated as 0.371. The top flooding test is performed using the similar process as described for Bed-1. The dryout heat flux is found as 161.82 kw/m 2. Figure 12 shows the comparison of dryout heat flux obtained from the experiment with various models, which illustrates that the value is closer to the predictions by Lipinski model and Reed s model. 180 170 160 150 140 130 120 Reed Lipinski Hu_Theof Schulen_Muller Experiment Fig. 12 Comparison of the dryout heat flux in Bed-2 with various models under top flooding conditions The effect of downcomer is also studied for Bed-2 using 12 mm size downcomer. The dryout heat flux obtained in this case is 188.39 kw/m 2. It is 16% higher than that of top flooding case, as shown in fig. 13. 200 190 180 170 160 150 140 130 120 110 100 Top-flooding 16% Downcomer-12mm Fig. 13 Effect of downcomer on dryout heat flux in Bed-2 14

NKS-DECOSE Report-2/2012 2013-06-17 4. Concluding remarks The tests carried out on the POMECO-FL facility using a bed packed with aluminum oxide gravel particles show the effective particle diameter of the gravel particles is 0.65 mm, by which the frictional pressure gradient can be predicted by the Ergun equation. After the water superficial velocity is higher than 0.0025 m/s, the pressure gradient is underestimated. The effective particle diameter of the zirconium particles is found as 0.8 mm. The dryout heat flux is measured on the POMECO-HT facility using particulate beds packed with the same particles as in POMECO-FL. The dryout heat flux of the bed with aluminum oxide gravels under top flooding is found to be close to the prediction of the Lipinski model. The dryout heat flux increases by 51% when applying a 12-mm size downcomer. The dryout heat flux of the bed with zirconium particles test lies between the values predicted by the Reed model and Lipinski model. The use of the 12-mm size downcomer increases dryout heat flux by 16%. 15

NKS-DECOSE Report-2/2012 2013-06-17 5. References Ergun, S., 1952, Fluid flow through packed columns, Chemical Engineering Progress, 48 (2), 89-94. Li, L.X., Ma, W.M., Thakre, S., 2012, An Experimental Study on Pressure Drop and Dryout Heat Flux of Two-Phase Flow in Packed Beds of Multi-Sized and Irregular Particles, Nuclear Engineering and Design, 242, 369-378. Lindholm, I., Holmström, S., Miettinen, J., 2006. Dryout heat flux experiments with deep heterogeneous particle bed, Nuclear Engineer and Design, 236, 2060 2074. Nemec, D. and Levec, J., 2005. Flow through packed bed reactors: 1. Single-phase flow. Chemical Engineering Science, 60, 6947-6957. Takasuo, E., Holmström, S., Kinnunen, T., Pankakoski, P., 2012. The COOLOCE experiments investigating the dryout power in debris beds of heap-like and cylindrical geometries, Nuclear Engineer and Design, 250, 687-700. 16

Bibliographic Data Sheet NKS-288 Title Author(s) Affiliation(s) Study on Effective Particle Diameters and Coolability of Particulate Beds Packed with Irregular Multi-size Particles Sachin Thakre, Weimin Ma, Pavel Kudinov, Sevostian Bechta Division of Nuclear Power Safety, Royal Institute of Technology, KTH, Sweden ISBN 978-87-7893-363-8 Date August 2013 Project NKS-R / DECOSE No. of pages 16 No. of tables 1 No. of illustrations 8 No. of references 5 Abstract One of the key questions in severe accident research is the coolability of the debris bed, i.e., whether decay heat can be completely removed by the coolant flow into the debris bed. Extensive experimental and analytical work has been done to substantiate the coolability research. Most of the available experimental data is related to the beds packed with single size (mostly spherical) particles, and less data is available for multi-size/irregular-shape particles. There are several analytical models available, which rely on the mean particle diameter and porosity of the bed in their predictions. Two different types of particles were used to investigate coolability of particulate beds at VTT, Finland. The first type is irregular-shape Aluminum Oxide gravel particles whose sizes vary from 0.25 mm to 10 mm, which were employed in the STYX experiment programme (2001-2008). The second type is spherical beads of Zirconium silicate whose sizes vary between 0.8 mm to 1 mm, which were used in the COOLOCE tests (Takasuo et al., 2012) to study the effect of multi-dimensional flooding on coolability. In the present work, the two types of particles are used in the POMECO-FL and POMECO-HT test facility to obtain their effective particle diameters and dryout heat flux of the beds, respectively. The main idea is to check how the heaters orientations (vertical in COOLOCE vs. horizontal in POMECO-HT) and diameters (6 mm in COOLOCE vs. 3 mm in POMECO-HT) affect the coolability (dryout heat flux) of the test beds. The tests carried out on the POMECO-FL facility using a bed packed with aluminum oxide gravel particles show the effective particle diameter of the gravel particles is 0.65 mm, by which the frictional pressure gradient can be predicted by the Ergun equation. After the water superficial velocity is higher than 0.0025 m/s, the pressure gradient is underestimated. The effective particle diameter of the zirconium particles is found as 0.8 mm. The dryout heat flux is measured on the POMECO-HT facility using particulate beds packed with the same particles as in POMECO-FL. The dryout heat flux of the bed with aluminum oxide gravels under top flooding is found to be close to the prediction of the Lipinski model. The dryout heat flux increases by 51% when applying a 12-mm size downcomer. The dryout heat flux of the bed with zirconium particles test lies between the values predicted by the Reed model and Lipinski model. The use of the 12-mm size downcomer increases dryout heat flux by 16%. Key words Debris bed coolability, Effective particle diameter, Particulate bed, Dryout heat flux Available on request from the NKS Secretariat, P.O.Box 49, DK-4000 Roskilde, Denmark. Phone (+45) 4677 4041, e-mail nks@nks.org, www.nks.org