Quartz glow-peaks lifetime analysis : Tl glow-curve deconvolution functions for first order of kinetic compared to Initial Rise Method

Similar documents
Thermoluminescence Properties of Local Feldspar from Gattar Mountain Area

A COMPUTER PROGRAM FOR THE DECONVOLUTION OF THERMOLUMINESCENCE GLOW CURVES K. S. Chung 1,, H. S. Choe 1, J. I. Lee 2, J. L. Kim 2 and S. Y.

Anomalous fading of the TL, Blue-SL and IR-SL signals of fluorapatite

Scholars Research Library. Thermally Stimulated Luminescence Studies of Silicate Minerals

A quantitative kinetic model foral 2 O 3 :C: TL response to ionizing radiation

Optically stimulated luminescence from quartz measured using the linear modulation technique

The Investigation of the Thermoluminescence Emission Bands of LiF:Mg,Ti (TLD-100) by a Simple Developed Model

A quantitative kinetic model for Al 2 O 3 :C: TL response to UV-illumination

Mechanism of Thermoluminescence


Modelling thermal activation characteristics of the sensitization of thermoluminescence in quartz

MIXED-ORDER KINETICS MODEL FOR OPTICALLY STIMULATED LUMINESCENCE

SIMULATION OF COMPETING FADING AND IRRADIATION EFFECTS IN THERMOLUMINESCENCE (TL) DOSIMETRY: 1 st ORDER KINETICS

Radiation Measurements

Scientific Journal Impact Factor: (ISRA), Impact Factor: Materials and methods. [Tiwari, 3(8): August, 2014] ISSN:

Thermoluminescent properties studies of spodumene lilac sample to dosimetric applications

Journal of Nuclear Sciences

A N Singh, S N Singh & L L Singh

The Effect of the Activation Energy, Frequency. Factor and the Initial Concentration of Filled. Traps on the TL Glow Curves of. Thermoluminescence

Influence of the Mechanical Sample Treatment on the Thermally Stimulated Exoelectron Emission in Aspect of the Application for Sample Dating

Thermoluminescence (TL) characterization of the perovskite-like KMgF 3, activated by Lu impurity

Pleistocene Terrace Deposits of the Crystal Geyser Area e. r G. P5 5o. M1/Qal. M3 3y M4 M5 M5. 5o M6y P6. M1/Qal

Nuclear Instruments and Methods in Physics Research B

SIMULATION OF OSL PULSE-ANNEALING AT DIFFERENT HEATING RATES: CONCLUSIONS CONCERNING THE EVALUATED TRAPPING PARAMETERS AND LIFETIMES

Charge recombination processes in minerals studied using optically stimulated luminescence and time-resolved exo-electrons

Spatial variation of dose rate from beta sources as measured using single grains

PUBLISHED VERSION.

Activation Energy of Modified Peak Shape Equations

3.9. Thermoluminescence

Supplementary information (SI)

Thermoluminescence kinetics for multipeak glow curves produced by the release of electrons

One-dimensional thermoluminescence kinetics

Study of the relationship between infrared stimulated luminescence and blue light stimulated luminescence for potassium-feldspar from sediments

Luminescence characterization of a sodium rich feldspar

Temperature effect on lyoluminescence of potassium halide microcrystals in luminol solution

GAMMA RAY SPECTROSCOPY FOR ARTIFICIAL CONTAMINATION EFFECTS EVALUATION IN LUMINISCENCE DATING OF ARTEFACTS FROM LOW DEPTH LAYERS IN SOUTHERN ROMANIA *

Mechanisms inherent in the thermoluminescence processes

Comparison of some models for nonlinear "tting analysis of TSC measurements

Analysis of Thermoluminescence Glow-Curves for. General-Order Kinetics Using Mathematica

PHYSICAL CHARACTERIZATION BY GAMMA (Γ) ENERGY SPECTROMETRY OF DRESSED ILMENITE ORE SAND FROM SOUTHEAST MADAGASCAR (FORT DAUPHIN)

THERMOLUMINESCENCE PROPERTIES OF OLIVINE

The trap states in the Sr 2 MgSi 2 O 7 and (Sr,Ca)MgSi 2 O 7 long afterglow phosphor activated by Eu 2+ and Dy 3+

CVD diamond for thermoluminescence dosimetry: optimisation of the readout process and application

How many grains are there on a single aliquot?

ROC7080: RADIATION THERAPY PHYSICS LABORATORY LAB TWO : THERMO LUMINESCENT DOSIMETRY

The predose effect in thermoluminescent dosimetry

INVESTIGATIONS OF THE RELATIVE EFFICIENCY OF THERMOLUMINESCENT DETECTORS TO PROTONS AT THE IFJ PAN KRAKÓW

Development And Testing of a Thermoluminescent Dosemeter for Mixed Neutron-Photon-Beta Radiation Fields

Anomalous fading: a reply to the comment by Huntley on "Isochron measurements of naturally irradiated K-feldspar grains"

Reply to comment by Huntley on "Isochron dating of sediments using luminescence of K-feldspar grains"

Radiation Measurements

Bonner Sphere Spectrometer. Cruzate, J.A.; Carelli, J.L. and Gregori, B.N.

Nuclear Instruments and Methods in Physics Research B

Characterization of Low-Energy (6-30 kev) Response of Polish TLDs (MTS-N, MCP-N) with Synchrotron Radiation and Determination of Some TLD Quantities.

Journal of Luminescence

RESULTS OF UNDERGROUND DOSE RATES USING TL DETECTORS AND PRELIMINARY TL CHARACTERISTICS OF IRRADIATED SALT ROCK *

THERMOLCIMINESCENCE OF

Laboratoire National Henri Becquerel (CEA/LIST/LNHB), France (2) ENEA-Radiation Protection Institute, Bologna, Italy (3)

ARTICLE IN PRESS. Journal of Luminescence

Further studies on the relationship between IRSL and BLSL at relatively high temperatures for potassium-feldspar from sediments

Survival Curves Models of Neutron Irradiation Data and Evidence for Hypersensitivity Phenomena

A Study on Radiation Damage in PWO-II Crystals

Scholars Research Library

TIME-RESOLVED LUMINESCENCE SPECTRA IN COLORLESS ANATASE TiO 2 SINGLE CRYSTAL

Package tgcd. September 6, 2016

An extremity (wrist) dosemeter based on the Landauer InLight TM whole body dosemeter

Imperfections (Defects)

Digital imaging of charged particle track structures with a low-pressure optical time projection chamber

Comparison of some human tissues and some commonly used thermoluminescent dosimeters for photon energy absorption

Introduction to Archaeology: Notes 9 Chronology, part 2 Copyright Bruce Owen 2009 Trapped-charge dating methods Several different kinds, one basic

Research Article Thermoluminescence Properties of Novel Self-Agglomerating CaSO 4 :Eu Phosphors Obtained by an Environmentally Friendly Method

Trace alpha-particle detection system for water networks: from direct detection in liquid phase to element identification

Source calibrations and blind test results from the new Luminescence Dating Laboratory at the Instituto Tecnológico e Nuclear, Sacavém, Portugal

THERMOLUMINESCENCE DATING OF POTTERY OBJECTS FROM TELL AL HUSN, NORTHERN JORDAN

Temperature accelerated Degradation of GaN HEMTs under High power Stress: Activation Energy of Drain Current Degradation

Study Some of Optical and Thermoluminescence Properties of Muscovite Mica Exposed to Ultraviolet Radiation

Neutron Dose near Spent Nuclear Fuel and HAW after the 2007 ICRP Recommendations

Energy Calibration of Liquid Scintillation Counter to allow Semi-Qualitative Nuclide Identification in Water Samples

A. Faanu *, G. Emi-Reynolds, E. O. Darko, R. Awudu, E.T. Glover, O. K. Adukpo, F. 1

4 α or 4 2 He. Radioactivity. Exercise 9 Page 1. Illinois Central College CHEMISTRY 132 Laboratory Section:

Multisphere Neutron Spectrometric System with Thermoluminescent Dosemeters: Sensitive Improvement

THE spectroscopic performance of large volume CdZnTe

Journal of Luminescence

INORGANIC crystal scintillators are widely used in high

Dating methods Stragraphic or geologic methods. Thomas INGICCO

The electron accelerator of the ISOF-CNR Institute: its characteristics and use

Investigation of the Asymmetric Characteristics and Temperature Effects of CdZnTe Detectors

Activation of Air and Concrete in Medical Isotope Production Cyclotron Facilities

OPERATING INSTRUCTIONS

The alpha effectiveness in silt-sized quartz: New data obtained by single and multiple aliquot protocols

EURADOS Intercomparison exercises on whole body and extremity dosemeters ( ) Outline and Results

PROBING LUMINESCENCE DATING OF ARCHAEOLOGICALLY SIGNIFICANT CARVED ROCK TYPES

Eigenvalue equation for momentum dispersion operator and properties of phase space wavefunctions

OSL in Household Salt (NaCl) for Environmental, Occupational and Medical Dosimetry

Joint ICTP-IAEA Workshop on Physics of Radiation Effect and its Simulation for Non-Metallic Condensed Matter.

Radionuclide Migration: Prediction Experience

THE COMPTON EFFECT Last Revised: January 5, 2007

Extension of the MCBEND Monte Carlo Code to Perform Adjoint Calculations using Point Energy Data

Luminescence. Luminescence / Band theory v2k13oct-nov R. C. Tailor, Asso. Prof. UT, M.D. Anderson Cancer Center

SCIENTIFIC DATING IN ARCHAEOLOGY

Transcription:

1 Quartz glow-peaks lifetime analysis : Tl glow-curve deconvolution functions for first order of kinetic compared to Initial Rise Method A. J. F. RATOVONJANAHARY, R. RABOANARY, RAOELINA ANDRIAMBOLOLONA Institut National des Sciences et Techniques Nucléaires (Madagascar-INSTN) B.P. 479, Antananarivo, Madagascar H. Y. GOEKSU GSF-Forschungszentrum fuer Umwelt und Gesundheit, Institut fuer Strahlenschutz D-85764, Neuherberg, Germany Quartz is a thermoluminescent material which has been used since the 60s for dating samples like potteries, flint, etc., but the method is still subect to some improvement. One of the problem of thermoluminescence dating is the estimation of the lifetime of the used peaks. The application of the glow-curve deconvolution (GCD) technique for the analyses of a composite thermoluminescence glow curve into its individual glow peaks has been applied widely since the 80s. Many functions describing a single glow peak have been proposed. For analysing quartz behaviour, thermoluminescence glow-curve deconvolution (GCD) functions are compared for first order of kinetic. The free parameters of the GCD functions are the maximum peak intensity (Im) and the maximum peak temperature (Tm), which can be obtained experimentally. The activation energy (E) is the additional free parameter. The lifetime () of each glow peak, which is an important factor for dating, is calculated from these three parameters. For lifetime analysis, GCD results are compared to those from initial rise method (IRM). Results vary fairly from method to method. 1. INTRODUCTION Quartz is one among the different materials used for thermoluminescence dating. One important point of this issue is the estimation of the lifetime of the used peak. Several methods were used, and initial rise method (IRM) is one among these methods. Results with these methods are quite similar and seem to be promising because of the calculated lifetime long enough for dating [1]. Besides, the application of the glow-curve deconvolution (GCD) technique for the analyses of a composite thermoluminescence glow curve into its individual glow peaks has been applied widely since 1980. Many functions describing a single glow peak have been proposed. The aim of the present work is first of all to compare two different programs for deconvolution, and secondly to compare the glow peaks lifetime calculation results from deconvolution to those from IRM. For the GCD, the program developed by J. M. Gomez-Ros and A. Delgado (CIEMAT, Spain) and the one developed by A. J. F. Ratovonanahary et al are compared. Firstorder kinetic is used for both and with second order approximation. The mineral used as TL material is quartz, and all the TL irradiation and TL reading are performed at GSF-Forshungszentrum fuer Umwelt und Gesundheit Munich Germany, at the TL-OSL unit of the Radiation protection department.. DECONVOLUTION As well the GCANEW program that GCDMAD uses the first-order kinetic with an approximation of the second order. In that condition, the kinetic equation is given by: Where kt E, kt m m, I is E E T Tm T E T Tm I ( T ) I m exp1 exp (1 ) kt T m Tm kt Tm the glow-peak intensity, E (ev) the activation energy, T (K) the heating temperature, Im the maximum intensity and Tm the temerature at which Im occurs. For fitting glow cuve, GCDMAD uses Marquardt Method. m

3. FIGURE OF MERIT (FOM) A possibility to be taken as a measure of the goodness-of-fit is a figure of merit originally defined by Balian and Eddy [4] and Misra and Eddy [5] which has proven very useful: FOM f i 100 y y( k A ) Where FOM = Figure Of Merit (%), i = first channel in the region of interest, f = last channel in the region of interest, y = information content of channel, y(x ) = value of the fitting function in channel, A = integral of the fitted glow-curve in the region of interest. Glow-curves with FOM values in excess of 5% are subected to further investigation to determine the reasons for the poor fit. 4. THE INITIAL RISE METHOD At the start of a glow-peak the thermoluminescence is proportional to exp(-e/kt), irrespective of whether first-order kinetics are obeyed or not. This temperature dependence continues until the number of electrons remaining trapped decreases significantly. Hence by plotting Log(thermoluminescence intensity) versus T-1 the value of E can be obtained from the slope of the straight line obtained. To avoid error due to a decrease in the number of electrons remaining trapped, it is necessary to restrict the temperature range such that the thermoluminescence intensity reached does not exceed one-tenth of the peak intensity. Of course, overlapping peaks on the lower edge of the peak under study need to be removed by prior thermal treatment. A drawback with this method is that if the relevant luminescence centres are subect to thermal quenching, too low a value is obtained for E. This can give rise to a value for the lifetime that is totally erroneous. Tm can be obtained from the TL glow curve intensity by sorting out TL intensity values. 5. GLOW-PEAKS LIFETIME Prediction of lifetime for the thermoluminescence peak of a mineral is helpful in establishing the likely time range over which it will be useful. The lifetime in the case of first-order kinetics is given by 1 E s exp kt Besides checking that a dating peak has adequate stability, determination of lifetime is also relevant with respect to the kinetic methods of annual dose evaluation. 6. QUARTZ GLOW-PEAKS LIFE-TIME ANALYSIS 6.1. Deconvolution 6.1.1. Quartz grains irradiation and read out The Merck Ltd. Company supplies the used quartz grains. These are pure and natural quartz grains from Brazil. Quartz grains have preliminary been treated: crushed, washed with chlorhydric acid, then heated at 90 C. For TL measurements, TL/OSL-DA-1 is used. This reader has a turntable containing 4 gap for planchet carrier and where one put the sample. This reader is equipped with incorporated 90Sr for beta source irradiation. Five samples of nearly the same amount are put on five different planchets. Each of them is preliminary heated 15 minutes at 500 C in order to ensure that all electrons traps are empty. Then, they are irradiated by approximately 10Gy of beta irradiation from 90Sr. After irradiation is the read out with maximum temperature of 500 C and ramp time of 100sec, i.e. of a heating rate of 5 C/sec.

3 6.1.. Deconvolution results Each glow-curve obtained after read out are deconvoluted. For the deconvolution, the program developed by J. M. Gomez-Ros and A. Delgado (CIEMAT, Spain) and the one developed by A. J. Franck Ratovonanahary (Madagascar-INSTN) are compared. First order kinetic is used for both ad with second order approximation. The CIEMAT program is called GCANEW and the one performed by Madagascar-INSTN is called GCDMAD. The results from these different programs are summarised in the following table. Table 1: Comparison of results from GCDMAD and GCANEW Peaks positions Tm ( C) E (ev) * FOM (%) GCDMAD Peak1 Peak Peak3 Peak4 Peak5 Peak6 115.9 ± 0. 146.9 ± 0.3 178.6 ± 0. 19.8 ± 0.4 77.6 ± 0.4 397.7 ± 0.3 1.0056 ± 0.0008 0.94 ± 0.01 1.044 ± 0.004 0.789 ± 0.005 1.03 ± 0.01 1.051 ± 0.004 1.103 ± 0.009 d 5.6 ± 0.8 d 161 ± 9 d 33 ± 3 d 70 ± 0 y 7300 ± 700 y 1.76 ± 0.03 GCANEW Peak1 Peak Peak3 Peak4 Peak5 Peak6 116. ± 0. 147. ± 0.3 178.9 ± 0. 0.5 ± 0.4 78. ± 0.4 398.7 ± 0.3 1.0060 ± 0.0007 0.94 ± 0.01 1.043 ± 0.004 0.788 ± 0.005 1.03 ± 0.01 1.051 ± 0.004 1.13 ± 0.007 d 5.6 ± 0.9 d 163 ± 9 d 34 ± 3 d 70 ± 0 y 7600 ± 700 y 1.64 ± 0.03 The table1 shows that these two deconvolution results are quite the same. Both of the program use 1st order kinetic second orders approximation, i.e. generally the same kinetic equation. The very slight difference between these results come from the difference of truncation. This result can also easily be seen in the figure1. Glow peaks from the two programs are quite the same. Sample1_GCDMAD_nd_order Sample1_GCANEW 6000 6000 5000 5000 TL intensity (a.u.) 4000 3000 000 1000 TL intensity (a.u.) 4000 3000 000 1000 0 0 100 00 300 400 500 0 0 50 100 150 00 50 300 350 400 450 500 Temperature ( C) Temperature ( C) TL glow -curve fitted glow -curve peak1 peak TL glow -curve fitted glow -curve peak1 peak peak3 peak4 peak5 peak6 peak3 peak4 peak5 peak6 Figure1: An example of TL glow-curve deconvolution. The two figures show the same glow-curve but the one in the left is deconvoluted by GCDMAD and the one in the right by GCANEW. Quartz grains are irradiated by 10Gy of -source. 6.. Initial Rise Method (IRM) Five samples of nearly the same amount are put on five different planchets. Each of them is preliminary heated 15 minutes at 500 C in order to ensure that all electron traps are empty. Then, they are irradiated by approximately 10Gy of beta irradiation from 90Sr.

4 The peak under study is peak6 appearing at about 400 C because of its half-life higher than all the other peaks. As overlapping peaks on the lower edge of the peak under study need to be removed by prior thermal treatment, after irradiation is the read out with maximum temperature of 300 C and ramp time of 150sec, i.e. of a heating rate of C/sec. The choice of C/sec is to have a heating rate slow enough for emptying all electrons traps on the lower edge of the peak under study. After the prior thermal treatment is the read out with maximum temperature of 500 C and ramp time of 100sec, i.e. of a heating rate of 5 C/sec (the same as for the running sequence for deconvolution in order to have the same condition for the best comparison). By plotting Log(I) versus T-1 the value of E can be obtained from the slope of the straight line obtained. Table : Peak6 lifetime result from IRM. The lifetime is calculated from the mean value of E and Tm. E (ev) T m ( C) (years) Mean values 1.44 40 49 000 000 uncertainties 0.006 1 7 000 000 The table shows clearly that the initial rise method gives lifetime value too much greater than the ones calculated by deconvolution. Further analysis showed that the combination of results from IRM and first order kinetic equation is not compatible with the measured glow-peak. Thus, one can say that IRM is not compatible with first order kinetic. 7. CONCLUSIONS (i) The estimation of the lifetime of the used peak is crucial because it should be long enough for estimating the age of a certain obect. IRM seems to be promising because of its long enough lifetime result (table). However, the latter method is not fully reliable. Firstly, the prior thermal treatment may not be complete because of the overlapping peaks on the lower edge of the peak under study, which is difficult to remove completely. Therefore, at the start of the glow-peak, the thermoluminescence is not really proportional to exp(-e/kt). Secondly, the prior thermal treatment permit to have a single glow-peak which does not follow the first order kinetic. (ii) GCD is the best way of analysing TL glow-curve. Indeed, This method is proved to be accurate. Firstly, with FOM test which is an accurate testing method, result (table1) shows that the quartz TL glow-curve is really in concordance with first order of kinetics model. Secondly, the GCD function for first-order kinetics produced in the GCANEW was used to analyse ten reference glow curves. The results were compared with results of the intercomparison presented in [6, 7]. The comparison shows that the proposed firstorder kinetic function is among the best of the 13 functions studied in [6, 7] and it is more accurate than other similar approximations previously used [5,8]. (iii) For comparison, results from GCDMAD are very close to the ones from GCANEW. That is normal because these two programs use the same kinetic function. The small difference on the results come from a difference of truncation. (iv) Peak lifetime from GCD is much shorter than the one from IRM (table 1 and ). For dating purpose, it is much more convenient to consider IRM results because the high length of used peak lifetime permit to work without any corrections. However, it may lead to misinterpretation if GCD results are considered. In fact, for example for dating an obect of around thousand years old, TL dating is possible because the age of the obect is less than the used peak lifetime irrespective of whether IRM or GCD is used. However, considering GCD results, some correction on dating estimation are necessary. (v) Our perspective work is to discover the law followed by the degradation of the used peak with time in order to be able to bring the adequate correction to the dating process.

5 Acknowledgement The authors would like to acknowledge the support of the Deutscher Akademischer Austauschdienst (DAAD), the GSF- Forschungszentrum fuer Umwelt und Gesundheit, and the Madagascar-INSTN. References [1] Aitken, M. J., Thermoluminescence dating, Research Laboratory for Archeology and the History of Art, Oxford University England (1985), pp.70-7. [] Chen R. and Kirsh Y. 1981 Analysis of Thermally Stimulated Processes in Solids (Oxford: Pergamon). [3] Podgorsak, E. B., Moran, P. R. and Cameron, J. R. Interpretation of Resolved Glow Curve Shapes in LiF(TLD-100) from 100K to 500K. In: Proc. 3rd Int. Conf. on Luminescence Dosimetry, Riso Report 49 (Denmark: IAEA and Danish AEC) p. 1 (1971). [4] Balian, H. G. and Eddy, N. W. Figure of Merit (FOM), an improved Criterion over the normalised Chi-squared Test for assessing Goodness-of-fit of Gamma Ray Spectra Peaks. Nucl. Instrum. Methods 145, 389-395 (1977). [5] Mirsa, S. K. and Eddy, N. W. IFOM, A Formula for Universal Assessment of Goodness-of-fit of Gamma Ray Spectra. Nucl. Instrum. Methods 166, 537-540 (1979). [6] Bos A J J, Piters T M, Gomez Ros J M and Delgado A. 1993 Radiat. Prot. Dosim. 47 p. 473 [7] Bos A J J, Piters T M, Gomez Ros J M and Delgado A 1994 Radiat. Prot. Dosùm 51 p. 57 [8] Podgorsak E B, Moran P R and Cameron J R 1971 Proc. 3rd Int Conf. on Luminescence Dosimetry, Riso, 11-14 October 1971, p.1