ChromTech options for PAL systems

Similar documents
COMBI. Gaschromatography. GC / GC-MS sample injector grows with your needs

PAL SPME Arrow The Better SPME

PAL SPME Arrow The Better SPME

Determination of Volatile Substances Proof of Food Adulteration

Application Note PB 401. Improve HPLC Sample Preparation in an Analytical Laboratory A New Automated Sample Preparation Process

Sensitive Detection of 2-MIB and Geosmin in Drinking Water

AppNote 2/2000. Stir Bar Sorptive Extraction (SBSE) applied to Environmental Aqueous Samples

TOTALLY INNOVATIVE MULTIMODE AUTOSAMPLER NEW KONIK ROBOKROM Laboratory Gas Generators An Overview +8 OPERATIONAL MODES MAIN FEATURES

Gas Chromatography (GC)

Chromatography. Gas Chromatography

Chemistry Instrumental Analysis Lecture 27. Chem 4631

OPTIMISATION OF SOLID PHASE MICROEXTRACTION (SPME) CONDITIONS FOR HEADSPACE ANALYSIS OF ORGANOPHOSPHATE PESTICIDES IN WHOLE BLOOD

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

-xt. -xt SYSTEM. Specifications for PAL-xt Systems. Valid for PAL-xt System models only. Prep and Load Platform

The Focus Robotic Sample Processor as a Tool for the Multiple Analysis of Samples using Complementary Techniques

Chemistry Instrumental Analysis Lecture 31. Chem 4631

Innovative Thermal Desorption From Agilent Technologies. Vivek Dhyani Application Chemist

Application. Gas Chromatography February Introduction

Chemistry Gas Chromatography: Separation of Volatile Organics

Introduction to Capillary GC. Page 1. Agilent Restricted February 2, 2011

ION CHROMATOGRAPHY SYSTEM S 150

Dynamic headspace (DHS) technique: set-up and parameter control for GC/MS analysis of odorant formulations

Application Note. Author. Abstract. Introduction. Hydrocarbon Processing

high performance OPTIC 3 and applications a total analytical solution

The Importance of Area and Retention Time Precision in Gas Chromatography Technical Note

A Comparative Analysis of Fuel Oxygenates in Soil by Dynamic and Static Headspace Utilizing the HT3 TM Automatic Headspace Analyzer

AppNote 6/2004. Thermal Desorption GC Analysis of High Boiling, High Molecular Weight Hydrocarbons SUMMARY

Sulfotepp impurities in Chlorpyrifos EC formulations

Chromatography Lab # 4

Gas Chromatography. Presented By Mr. Venkateswarlu Mpharm KTPC

GC/MS Application Note

STANDARD OPERATING PROCEDURES

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

Method for the determination of 1,3-butadiene

Headspace Technology for GC and GC/MS: Features, benefits & applications

Thermo Scientific TriPlus RSH Autosampler Integrated Sampling System. You are productive solving your chromatography challenges

Chemical Analysis Problem

Determination of Off-Odor Compounds in Drinking Water Using an SPME Device with Gas Chromatography and Mass Spectrometry

Chapter content. Reference

anthracene Figure 1: Structures of Selected Polyaromatic Hydrocarbons (PAHs)

TechNote 5/2002 KEYWORDS ABSTRACT. SBSE, Twister, Thermal Desorption

Determination of volatiles in Food sample preparation strategies and techniques Dr Kathy Ridgway

Analysis of Geosmin and 2-Methylisoborneol Utilizing the Stratum PTC and Aquatek 70

Automated Sample Preparation of Headspace Standards Using the Agilent 7696 WorkBench

881 Compact IC pro 882 Compact IC plus. Compact ion chromatography for intelligent, reliable and precise analysis

Determination of Volatile Aromatic Compounds in Soil by Manual SPME and Agilent 5975T LTM GC/MSD

Introduction to Capillary GC

TETRACHLOROETHYLENE IN URINE BY GC/MS Headspace Code GC15010

Simultaneous Estimation of Residual Solvents (Isopropyl Alcohol and Dichloromethane) in Dosage Form by GC-HS-FID

Determination of releasable 2,4,6-trichloroanisole in wine by cork stoppers (Resolution OIV-Oeno 296/2009)

Activity in the FID Detection Port: A Big Problem if Underestimated

Gas Chromatography (Chapter 2 and 3 in The essence of chromatography)

Selection of a Capillary GC Column

METHYLISOBUTYLKETONE (4-methyl-2 pentanone) IN URINE BY GC/MS Headspace Code GC10510

GC Application Note. Dilution/standard addition: Efficient and traceable.

Chromatography- Separation of mixtures CHEM 212. What is solvent extraction and what is it commonly used for?

Rapid Catalyst Screening Reactors

Chromatography and its applications

Agilent G3212 GC-APCI Source

Gas Chromatography (GC)! Environmental Organic Chemistry CEE-PUBH Analysis Topic 5

Fast Gas Chromatography using Heated Headspace Gas Auto Sampling Techniques: Ethylene Oxide and 1,4-Dioxane in Fatty Acids

TRICHLOROETHYLENE IN URINE BY GC/MS Headspace Code GC16110

GAS CHROMATOGRAPHY (GC)

Chapter 27: Gas Chromatography

Lecture 7. Sorption-Separation Equipment

Application. Gas Chromatography March 1998

Understanding Gas Chromatography

In-Tube Extraction Sample Preparation for Gas Chromatography

Anethole. Gas chromatograhpy determination of trans-anethole in Spirit srinks of viti-vinicultural origin

Chem 230, Fall, 2014 Homework Set # 3 Short Answer SOLUTIONS

GCXGC-qMS with Total Flow Modulation for Volatile secondary metabolites analysis from organically-grown apples by HS-SPME

Screening of Pesticide Residues in Water by Sequential Stir Bar Sorptive Extraction-Thermal Desorption with GC/MS

Electronic Supplementary Material Experimentally Validated Mathematical Model of Analyte Uptake by Permeation Passive Samplers

AppNote 1/2007. Automated Dynamic Headspace Sampling using Replaceable Sorbent Traps KEYWORDS ABSTRACT

LC walk-up system using the Agilent 1200 Series LC Method Development Solution and Agilent Easy Access software. Application Note

VOC Analysis of Water-Based Coatings by Headspace-Gas Chromatography

Transferring HPLC methods from the HP 1090 Series to the Agilent 1100 Series HPLC system

GC Instruments. GC Instruments - Sample Introduction

METHYLETHYLKETONE (M.E.K.) IN URINE BY GC/MS in head space Code GC10010

ABB MEASUREMENT & ANALYTICS DATA SHEET. PGC5000 Temperature programmed gas chromatograph

*Correspondence to:

Introduction to Capillary GC

Figure 1. Structures for Vitamin B2 and Vitamin B1.

Solid Phase Microextraction

GC/MS Application Note

SOPHAS - Speeding up the process of discovery and optimisation

Introduction and Principles of Gas Chromatography

Fundamentals of GC: Introduction: Sample introduction:

GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY

Petrochemical. Transformer Oil Gas Analysis - TOGA

Detection of Chemical Warfare Agents by Transportable GC/MS

Analysis of BTEX in Natural Water with SPME

Analytical Microextraction: Current Status and Future Trends

Chromatographic Methods of Analysis Section: 5 Gas Chromatography (GC) Prof. Tarek A. Fayed

2401 Gas (liquid) Chromatography

Figure 1. Structures for Vitamin B2 and Vitamin B1.

Residual Solvents in Pharmaceuticals by USP Chapter <467> Methodology

Evaluation of a New Analytical Trap for Gasoline Range Organics Analysis

High Performance Liquid Chromatography

Transcription:

ChromTech options for PAL systems SPDE features full automation for dynamic sample extraction, desorption and analysis using the CTC Combi PAL. Most of our customers use SPDE for food and flavor research, forensic analysis or environmental applications. The typical lifetime of a single SPDE syringe is 1500 injections, though can be higher if a clean matrix is used. A gas-tight 2.5mL syringe is equipped with a special needle that is coated on the inside with an extraction phase. The phase can be applied in varying degrees of thickness. The adsorption process is best described as follows: A liquid or headspace sample is drawn up into a 2.5mL syringe, thereby adsorbing analytes onto the stationary phase. A distribution balance is reached between the liquid sample matrix and the active phase. The analytes are concentrated onto the phase by repeatedly moving the plunger up and down, thereby forcing the headspace or fluid through the needle. Fast plunger speeds ensure a quick exchange of sample near the active phase. After adsorption, the syringe picks up carrier gas from the fiber bakeout station (if necessary, the station is also used to dry the coating and syringe). Then, the autosampler moves the syringe over to the hot GC inlet, and the analytes are desorbed. Additional gas flow from the syringe forces the analytes into the inlet, thereby ensuring sharp peak shapes. This technique can be used with splitless flow for maximum sensitivity. System Type: Dynamic extraction of liquid and gaseous samples Use of various phases and film thickness No mechanical or thermal stress High-grade steel capillary needle, which adds to its robustness Analyze a sample while extracting the next one Fully automatic use with a standard PAL system and any chromatographic system with split/splitless injector No extra thermal desorption system needed Total control of all extraction parameters More convenient than other extraction methods Less time necessary for sample incubation Needle coated on the inside walls with a choice of phases and variable thicknesses Optimized sample contact with the phase is reached by setting the number of plunger pumpings, resulting in shorter incubation time SPDE-Syr2.5ml SPDE Syringe 2.5 ml, gastight, for screw-on needles for use with replaceable SPDE needles, 56 mm or 74 mm SPDE-2630022 Teflon seals for SPDE Syringe Plunger, 5 per pack Replaceable needles, coated, 56 mm: SPNdl-01-50-56 SPDE Syringe needle, coated with PDMS, 50 μm, 56mm SPNdl-01/AC-50-56 SPDE Syringe needle, coated with PDMS/AC, 50 μm, 56 mm, coated with PDMS+10% active charcoal SPNdl-5-50-56 SPDE Syringe needle, coated with CT-5, 50 μm, 56 mm, coated with 5% Diphenyl / 95% Dimethylpolysiloxane, 50 μm. SPNdl-WAX-50-56 SPDE Syringe needle, coated with Polyethylenglycol (Carbowax), 50 μm, 56 mm SPNdl-1701-50-56 SPDE Syringe needle, coated with CT-1701, 50 μm, 56 mm, coated with 14% Cyanopropyl / 86% Dimethylpolysiloxane SPNdl-225-50-56 SPDE Syringe needle, coated with CT-225, 50 μm, 56 mm, coated with 25% Cyanopropyl / 25% Phenylpolysiloxane / 50% Methylpolysiloxane. SPNdl-Cust-56 SPDE Syringe needle, coated with custom phase, 50 μm, 56 mm. (Please specify phase coating)

A SPDE-option for volatile components Since the introduction of SPDE, various users have expressed the desire to be able to extract volatile substances even better. Since the SPDE syringe needle usually works at ambient temperatures or at sample temperature during the extraction, volatile substances are poorly extracted compared to less volatile components. This is also a limitation for SPME. In contrast to this method, SPDE accomplishes these applications by means of intensive needle cooling! With the use of the SPDE Extraction Cooler, very volatile components can easily be extracted without problem. Figure 1 shows a schematic drawing of the extraction cooler, which uses a Peltier-cooler for the SPDE needle. The cooler is installed on top of the CHROMTECH single magnet mixer (SMM) (fig. 2) and reaches temperature differences of up to 40 C. This means the needle can cool down to -15 C while working at an ambient temperature of 25 C. Features: For volatile components VOCs in drinking water Simultaneous sample heating and needle cooling Easily mounted Retrofitable for all Single Magnet Mixers (SMM) Peltier-cooling Working range up to 40 C below ambient temperature Fig. 1: Principle of the automated SPDE extraction. The analyte is enriched by controlled pumping through the specially coated syringe needle. Extraction Cooler: The analyte accumulates inside the SPDE needle at -15 C and is then thermally desorped. During enrichment, the sample is heated while the needle is being cooled. Fig 2: The SPDE - Extraction Cooler is simply mounted on top of a Single Mixer. The SPDE needle penetrates the vial only by a few millimeters.

"For SPME and SPDE Applications" What is a Single Magnet Mixer? This unit is nothing more than an automated stirring plate, which rotates the magnet located in each vial at speeds of up to 750RPM (1500RPM option available). At the same time, it can be used to heat or cool your sample. The most beneficial application of the Single Magnet Mixer is SPME immersed in liquid. When immersed in liquid, the SMM is gentle with the fiber and needle. The liquid is mixed by a small magnet inside the vial and creates a vortex at high speeds. Fiber lifetime is significantly increased due to the gentle mixing within the SMM. System Features Intensive mixing capability by using magnetic stir bar for quick equilibrium Easy comparison/transfer between manual and automated methods No temperature gradients inside the vial even while sampling Heats up to 150 C Optional Peltier Cooling available Fully automated sampling through closed housing PAL controls all heating and mixing cycles Controllable with Firmware or Cruise Control Software SMMs for 2mL, 10mL or 20mL vials

Large Volume Headspace Oven With the Baker Option for your Combi PAL, headspace is automatically determined for voluminous samples! A container with the sample is placed on the plate elevator of the PAL Baker. As soon as the sampling mode is started, the container elevator moves upwards until the heating compartment is completely closed. After reaching a pre-set temperature followed by the incubation time, a heated gas-tight syringe withdraws a defined sample amount out of the heated container. Finally the gas sample is injected into a GC or GC/MSsystem for detection. The sample elevator moves back to its starting position, allowing the analyzed sample to be removed from the container. The sampling compartment and syringe are now purged by an inert gas. System type: Sample compartment opens and closes automatically No sample transfer lines or switching valves Full automatic use with standard PAL System and GC with SSL injector. Sample compartment heats up to 165 C Purge gas flow after each analysis no contamination! Leak-tight sample compartment with 750ml capacity Sample containers up to 135 mm hight x 75 mm diameter For use with glass or metal containers PC Cruise Control Software Works with HP/Agilent ChemStation or ThermoQuest Xcalibur Available as a complete analytical solution including Agilent 6980 GC,Combi PAL, Baker and Chromatography Data System Applications: Analysis of Solvents in Paper, Tissues etc. Analysis of Solvents in Plastics, Powers, Granules etc. Analysis of Solvents in pharmaceutical products, e.g. tablets etc.

PrepBase The PrepBase is an attachment for the CTC PAL system that performs online filtration. It uses Whatman Mini-UniPrepTM vials to filter all types of sample matrices. The PrepBase can be customized to fit your application and needs. System: Suitable for all vial types Works with deepwell and microplates Dilution of sample and/or standards Prepares dilution series Extractions (SPE, SPME, SPDE) Filtration Sample shaking or stirring Sample heating or cooling Transports vials GL Sciences B.V. De Sleutel 9 5652 AS Eindhoven Tel: 040 2549531 info@glsciences.eu www.glsciences.eu