Complete Moisture Analysis

Similar documents
Complete Moisture Analysis

Labcell Water Activity Instruments

AquaLab Water Activity Instrumentation

Automated multi-vapor gravimetric sorption analyzer for advanced research applications

Vapor Sorption Analyzer

DVS Intrinsic Compact and Economical Dynamic Vapor Sorption System

DYNAMIC VAPOR SORPTION ANALYZER FULLY AUTOMATED COMPACT BENCH-TOP DVS ANALYZER, FOR FAST AND ACCURATE SORPTION MEASUREMENTS.

Thermal Analysis Excellence

COMPLETE MOISTURE ANALYSIS

DVS INTRINSIC. The easy-to-use solution to complex water sorption challenges.

Heat stress index. Dewpoint. pressure. altitude

WATER ACTIVITY MEASUREMENT WATER ACTIVITY

Application Note. Fundamentals of Moisture Sorption Isotherms. Hysteresis

D501 and D501-RS. Microscanner D-Series IR Thermometers. no effect. no effect. no effect. no effect no effect

Kestrel 4500 Pocket Weather Tracker

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

473-SHX Dew Point Mirror

Understanding Importance of Water Sorption Isotherm Shape, Hysteresis, and Models on Pharmaceutical Materials

473 Dew Point Hygrometer

Humidity Calibration Solutions

cobas e 411 analyzer Confidence in every result.

Elcometer 116C. Sling Hygrometer. Operating Instructions

11/23/ (4) Harmonization Stage 6: <1241> Water Solid Interactions in Pharmaceutical Systems (USP34 NF29 2S) BRIEFING

Water & Vapor Sorption

Astoria-Pacific proudly offers our rapid-t software for the ChemWell-T an easy-to-use, compact automated chemistry analyzer:

The Fundamentals of Moisture Calibration

473 Dew Point Hygrometer

TA INSTRUMENTS. Vapor Sorption Analysis

FoodScreen Radiological Food Screening System

Humidity Calibration Solutions

Your partner in Science!

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

Data Sheet / Instructions. Dewpoint MeterO

Spectrometer User s Guide

Dewpoint Meter Data Sheet / Instructions

This sensor is now also available with a sturdier flat electrode which enables testing even smaller samples than the conventional electrode.

Innovative. Intuitive. Concentration (ppb) R = Versatile. Hydra II C Mercury Analyzer

J R. TransTech Systems T S. The World s Number 1 Supplier Of Non Nuclear Density Meters for Asphalt Pavements and Engineered Soils

Minimum (-31) every 10 s -35 (-31)

Techniques for Fast Measurements of Low Dewpoint in Portable Hygrometers

Freezing point osmometry

Overview Brochure Comprehensive range of instrumentation for the measurement of moisture and oxygen

Drug Testing Solutions INDIKO DRUG TESTING ANALYZER. 1 P F

DM70. Hand-held Dewpoint Meter. Truly Fast Response - Superior Long-term Stability

Laird Thermal Systems Application Note. Precise Temperature Control for Medical Analytical, Diagnostic and Instrumentation Equipment

3URGXFWLQIRUPDWLRQ 5HVHUYDWLRQRISURSHUW\ULJKWV

University of Minnesota Nano Center Standard Operating Procedure

Understanding uncertainties associated with the 5128A RHapid-Cal Humidity Generator

Ocean Optics Red Tide UV-VIS Spectrometer (Order Code: SPRT-UV-VIS)

Edgetech Instruments Inc.

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure

Understanding the uncertainties associated with using the 5128A RHapid Cal portable humidity generator

DHS1900 DHS3000 High Temperature Hand Held Infrareds User Manual

The solution for all of your

Vaisala DRYCAP Hand-Held Dewpoint Meter DM70. Fast Response - Low Maintenance

Chilled Mirror Hygrometry

ASTORIA PACIFIC. Automated Wet-Chemistry Analyzers and Diagnostic Reagents. rapid-t

Surface Measurement Systems

cobas c 111 analyzer Big analyzer performance in a small package

O P E R A T I N G M A N U A L

Thermo Scientific Orion Star T900 Series Laboratory Titrators. Potentiometric titrators for performing automated ph, redox, or ion titrations

A Dynamic Method Determining Equilibrium Moisture Content of Porous Materials

STATIC GAS MONITOR Type SGM/DEW Revision A of 20 aprile 2016

This page intentionally left blank

425 Jordan Road SOP. No. 10 Rev. No. 1.3 Troy, NY Date: 03/14/2012 Page 1 of 7

The Vacuum Sorption Solution

User s Guide. Waterproof Palm ph Meter Model PH220. Introduction

Moisture Analyzers.

WATER-ACTIVITY TESTING

Simple Use Compact and Robust Fast and Efficient

EVEN THE FINEST CANNOT ESCAPE. Wöhler SM 500 Suspended Particulate Analyser


SUGAR/BRIX REFRACTOMETER INSTRUCTION MANUAL

EAS 535 Laboratory Exercise Weather Station Setup and Verification

Air velocity & IAQ measuring instruments

Freezing point osmometry

THM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist

ISSP User Guide CY3207ISSP. Revision C

Photosynthesis and Respiration. Evaluation copy

An ultra-sensitive, versatile, and affordable single tube luminometer for Life Science Research.

Lab Activity H4 It s Snow Big Deal

792A AC/DC Transfer Standard

CALIBRATION. Calibration. General Principles & Theory, Equipment Considerations. Copyright Caltech 2014

792A AC/DC Transfer Standard

PTG-NIR Powder Characterisation System (not yet released for selling to end users)

Water & Vapor Sorption

C101-E112. BioSpec-nano. Shimadzu Spectrophotometer for Life Science

Structure Monitoring Technology. Features. Ordering Information. Trigger Tape. A2 Pulse Counter (Optional) Solar Radiation Sensor

High Accuracy High Speed in Your Process

QDTL. Liquid Mass Transfer and Diffusion Coefficient Unit PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION. Electronic console

Non - Contact Forehead Infrared Thermometer. Care Q7 USER MANUAL - 1 -

BECKMAN COULTER QbD1200 Total Organic Carbon Analyzer Critical Measurements Made Simple

Application Note. Introduction

Spectrophotometer for Life Science. BioSpec-nano C101-E112D

Kjeltec 2300 Analyzer Unit

ActiPix SDI300 Surface Dissolution Imaging System

Biochrom Libra. UV-Visible Spectrophotometers. High performance instruments with added application value for academia, research and industry

NATURAL ROCK SAMPLE. Performance Monitoring Accessory for the RAD7 User Manual

Traceable Big-Digit Type-K Thermometer Big digits are readable from 15 feet away. For additional Type-K probes, see page 41.

SIMATIC Ident Industrial Identification Systems

Transcription:

Complete Moisture Analysis Water Activity Instrumentation Dew Point Water Activity & Moisture Analysis Moisture Sorption Isotherms Accessories PRODUCT CATALOG 2013-2014

DEW POINT Water Activity Use Aqualab 4TE for lab quality water activity measurements at the line, receiving dock, processing plant, storage facility anywhere you need to verify the safety and quality of your products and ingredients. How it Works Put a 7.5 ml product sample in a disposable cup, seal the chamber over the sample, and wait for vapor equilibrium. An optical sensor focused on a tiny mirror triggers the precise dewpoint temperature measurement of the sample. That dewpoint temperature is then translated into water activity. Easy to Clean The chamber lid lifts up allowing easy access to clean sensors. Secure Data The 4TE stores up to 8,000 secure data points including time and date for up to 25 unique users with every measurement and calibration. Easy to Use AquaLab 4TE makes water activity measurements quick, accurate, and simple. Using AquaLab, anyone, from a researcher in the lab to an operator at the line can measure water activity in 5 minutes or less to 0.003 a w specifications. AQUALAB 4TE SPECIFICATIONS Sensor Types: Chilled-mirror dew point, Infrared temperature Accuracy: ±0.003 a w Range: 0.030 to 1.000 a w Repeatability: ±0.001 a w Resolution: ±0.0001 a w Measurement Time: Less than 5 min (most samples) Operating Environment: 5 to 50 C (39.2 to 122 F) 20 to 80% Relative Humidity (non-condensing) Temperature Control: 15 to 50 C (±0.2 C) Universal Power: 110 V to 220 V AC, 50/60 Hz Less than 0.4 amps Data Interface: USB & RS232A Compatible Warranty: Three years, factory parts & labor Test Result Memory: 8,000 readings (each reading includes water activity, temperature, time, date, operator, and sensor used) Program Identification: Alphanumeric; Programmable to display product name, lot, or product ID number Certifications: CE; AOAC Approved Method for Measurement of Water Activity AQUALAB 4TEV SPECIFICATIONS Samples Containing Volatiles: All the features of the Series 4TE plus a volatiles sensor for measuring samples containing propylene glycol, ethanol and other volatiles. Easy Switching: The AquaLab 4TEV comes with both a volatiles capacitance sensor and the standard Series 4 dewpoint sensor. You can switch between sensors using the 4TEV instrument menu. Volatiles Sensor Accuracy: ±0.015 a w Dewpoint: ±0.003 a w 1 WATER ACTIVITY

The AquaLab 4TE DUO uses the dewpoint method to measure moisture content and water activity with the same instrument. The result: complete moisture analysis in about five minutes with some big advantages over traditional moisture meters. DEW POINT Moisture Content How it Works The dewpoint method doesn t use chemicals or high temperatures. Using it is as easy as sealing the sample in the chamber and waiting for vapor equilibrium. Inside the instrument, a optical sensor focused on a tiny mirror triggers the precise dewpoint temperature measurement of the sample. That dewpoint temperature is then translated into moisture content and water activity readings. Because the instrument is lightweight, portable, and easy to use, it puts precision moisture content readings in the hands of virtually anyone on the production line or in the supply chain. Testable Accuracy Standardization issues have often made moisture content more opinion than fact. As one manufacturer said, My suppliers quote me what the moisture content was when the ingredient shipped. That number s meaningless. They can say whatever they want because we don t have reliable standards to measure against. The dewpoint method lets you validate moisture content readings with independently verifiable salt standards. DUO stores time, date, and user information with every calibration and measurement, and includes administrator passwords and access restrictions so you can ensure the integrity of your data. AQUALAB 4TE DUO SPECIFICATIONS Sensor Types: Chilled-mirror dewpoint, infrared temperature Accuracy: ±0.003 a w Range: 0.030 to 1.000 a w Moisture Content Precision: 0.02% Agreement to Moisture Content Reference Method: ±0.1% to ±0.5% Resolution: ±0.01% mc ±0.0001 a w Measurement Time: Less than 5 min (most samples) Results Displayed: Percent moisture and water activity Temperature Control: 15 to 50 C (±0.2 C) Temperature Stability: User-selectable range, internal thermoelectric controlled Test Result Memory: 8,000 readings (each reading includes water activity, moisture content, temperature, time, date, operator, and sensor used) Program Identification: Alphanumeric; Programmable to display product name, lot, or product ID number Operating Environment: 4 to 50 C (39.2 to 122 F) 0 to 90% Relative Humidity (noncondensing) Universal Power: 110 V to 220 V AC, 50/60 Hz Less than 0.4 amps www.aqualab.com MOISTURE CONTENT 2

Moisture Sorption Isotherms The AquaLab VSA is a powerful formulation tool. It shows how a product s water activity changes as it takes on and loses water. It uses chilled mirror technology to create high resolution moisture sorption isotherms based on hundreds of data points in about 48 hours. An easy to use software program simplifies data collection and analysis. Isotherms The relationship between water activity (a w ) and moisture content at a given temperature is called the moisture sorption isotherm. This relationship is complex and unique for each product due to the different interactions (colligative, capillary, and surface effects) between the water and the solid components at different moisture contents. An increase in a w is almost always accompanied by an increase in water content, but in nonlinear fashion. Moisture sorption isotherms are sigmoidal in shape for most foods, although foods that contain large amounts of sugar or small soluble molecules have a J-Type isotherm shape. Isotherms hold the key to understanding moisture in food and pharmaceutical products. Isotherms help you: Set Specifications Determine the most stable water activity for your food product and predict reactions and textural changes that end shelf life. USES FOR ISOTHERMS Phase Changes Shelf Life Texture Kinetics Caking /Clumping Packaging Guide Formulation Map out how an ingredient or recipe will respond as you change formulation. DDI Isotherm Generation In DDI mode, the AquaLab VSA exposes a sample to saturated wet air for adsorption and desiccated air for desorption. As the sample dynamically takes up or loses moisture, the change in humidity is determined directly using a dewpoint sensor and the weight change is tracked with a precision balance to create a detailed moisture sorption isotherm for the sample. See Details Typical isotherms have fewer than a dozen data points with DDI Isotherms. AquaLab Vapor Sorption Analyzer generates over 100 data points for each isotherm curve. Measure Stability Predict how abuse conditions like high humidity will affect shelf life. 3 3 MOISTURE SORPTION ISOTHERMS

Dynamic and Static Methods - One Instrument Dry milk powder DVS Isotherm Generation The AquaLab VSA also offers traditional DVS isotherm generation. DVS analyzers step humidity to a specified level and hold the sample at that humidity until it comes to vapor equilibrium. In DVS mode, the VSA produces isotherms equivalent to those produced by any existing vapor sorption analyzer. Use DVS to explore: Kinetics of sorption Moisture diffusion coefficients Product surface area and pore size Packaging requirements In package desiccant requirements Maximum moisture sorption Moisture Migration Crystallization AQUALAB VSA SPECIFICATIONS Repeatability: ±0.003 a w Range: 0.030 to 0.950 a w Isotherm Methods: Dynamic Dewpoint Isotherm (DDI) and Static (DVS) External Gas: Not needed, If external gas, no more than 7 PSI Data Interface: USB Mass Resolution: ±0.1 mg Water Activity: Accuracy ±0.005 a w Water Reservoir: 20 ml Sample Cup Volume: 10 cc Sample Weight: 500 to 5,000 mg Power: 110 V to 220 V AC, 50/60 Hz Weight: 28 lbs Temperature: 15 to 60 C Temp Stability: ±0.1 C Dimensions: 10 x 15 x 12 in (25.4 cm x 38.1 cm x 30.5 cm) The Vapor Sorption Analyzer has become an invaluable insturment to our R&D lab. The Dynamic Dew Point Isotherm (DDI) method allows us to generate an isotherm in 12-24 hours, at a wide range of temperatures. The Dynamic Vapor Sorption (DVS) method provides a fully automated process of obtaining kinetics of moisture uptake in our products. The Test Wizard function in the software allows for quick and easy test set-up, and exporting the results is done with one click of a button. The Vapor Sorption Analyzer has provided us with very reliable and repeatable results that have been instrumental to the development or our products. Thanks! Kara Grant, GMCR Specialty Coffee Business Unit www.aqualab.com DYNAMIC/STATIC ISOTHERMS 4

Water Activity The AquaLab Pre is a robust entry-level water activity meter with stripped down form, not limited function. It uses the same industry-standard primary a w method you find in the top-of-the-line AquaLab Series 4TE. The Pawkit delivers ultra-compact ±0.02 a w measurements in 5 minutes. This sleek device is compact, lightweight, portable, and only 4 inches long. Ideal for rough environments where quick, inline water activity measurements are needed. Staple for safety inspectors, and consultants. PRE SPECIFICATIONS Minimum maintenance Pre uses the dewpoint method a primary measurement of water activity. That eliminates the need for lengthy sensor calibration. Just a quick verification check and you re good to go. Real Water Activity FAST No need to sacrifice accuracy for speed. Primary dewpoint measurement allows Pre to deliver top-accuracy readings in 5 minutes or less. Solid Repeatability Water activity is temperature dependent; measuring at the same temperature every time assures consistency in your readings. Pre holds the sample at 25 C so temperature fluctuations won t affect your readings. Reliable Accuracy Pre s dewpoint method and temperaturestable features mean good agreement between the Pre and the Series 4. Its basic 0.01 a w accuracy enables many of our customers to add water activity testing at the line, loading dock, or offsite facility. 5 CAPACITANCE WATER ACTIVITY Sensor Types: a. Chilled-mirror dewpoint, b. Infrared temperature Accuracy: ±0.01 a w Resolution: Chilled Mirror ±0.001 a w Range: 0.05 to 1.000 a w Sample Dish Capacity: 7 ml recommended (15 ml full) Measurement Time: Less than 5 minutes Operating Environment: 4 to 50 C (39.2 to 122 F) 0 to 90% Relative Humidity (non-condensing) Temperature Control: 25 C Sample Temperature Universal Power: 110 V to 220 V AC, 50/60 Hz Less than 0.4 amps Data Interface: RS232A compatible, 8-data bit ASCII code, 9600 baud, no parity, 1 stop bit Warranty: One year, parts & labor Certifications: CE; AOAC Approved Method for Measurement of Water Activity Display: 20 x 2 alphanumeric display with backlighting Accuracy: ± 0.2 C Case Dimensions: 24.1 x 22.9 x 8.9 cm Case Material: Powder painted aluminum Weight: 3.2 kg PAWKIT SPECIFICATIONS Sensor: Dielectric humidity sensor Accuracy: ±0.02 a w Resolution: ±0.01 a w Range: 0 to 1.0 a w Operation environment: 5 to 50 C (41 to 122 F) 0 to 90% relative humidity (non-condensing) Measurement speed: 5 minutes Battery life: 3 years typical

Software AquaLink Software helps users organize, visualize, and track measurement data. AquaLink Software downloads measurements made by AquaLab Dew Point Water Activity Meters and creates Microsoft Excel reports containing user selected pertinent information. AquaLink Software manages isotherm models on AquaLab Dew Point 4 DUO instruments. BENEFITS: Manages multiple AquaLab 4 instruments Improved data filtering capabilities Easily generate Microsoft Excel files or copy and paste measurements directly Now includes graphing system to analyze data Simplified isotherm model management User configurable annotations and notes Part 11 Compatible available Now supports Windows XP/Vista /7* Accessories Verification Standards Sample Cups Cleaning Kit Premixed, certified salt solutions for daily AquaLab performance verifications. Select standards which cover the range of water activities you typically measure. Unopened vials have a one year shelf life. AVAILABLE STANDARDS: Distilled water (1.000 ± 0.003 a w at 25 C) 0.5 M KCl (0.984 ± 0.003 a w at 25 C) 2.33 NaCl (0.920 ± 0.003 a w 25 C) 6.0 M NaCl (0.760 ± 0.003 a w at 25 C) 8.57 M LiCl (0.500 ± 0.003 a w at 25 C) 13.41 M LiCl (0.250 ± 0.003 a w at 25 C) 15 ml disposable sample cups and lids. Used in the AquaLab Series 4 (4TE, 4TEV, 4DUO), Pawkit and AquaLab Lite. AVAILABLE IN BOXES OF 500 & 2,500 Contains all cleaning materials needed to clean a benchtop water activity meter, a portable water activity meter, or a vapor sorption analyzer for one year for most customers. 1 YEAR SUPPLY www.aqualab.com * Windows is a registered trademark of Microsoft Corporation in the United States and other countries. SOFTWARE & ACCESSORIES 6

Distributed by: 2365 NE Hopkins Court Pullman, Washington 99163 USA 1-509-332-2756 instruments@aqualab.com www.aqualab.com PRINTED IN USA