Calibration and Performance of the ATLAS Tile Calorimeter During the LHC Run 2

Similar documents
ATLAS Tile Calorimeter Calibration and Monitoring Systems

Simulation and validation of the ATLAS Tile Calorimeter response

Available online at Physics Procedia 37 (2012 )

ATLAS NOTE October 12, 2009

STATUS OF ATLAS TILE CALORIMETER AND STUDY OF MUON INTERACTIONS. 1 Brief Description of the ATLAS Tile Calorimeter

ATLAS Hadronic Calorimeters 101

arxiv: v2 [physics.ins-det] 19 Nov 2010

ATLAS Tile Calorimeter performance for single particles in beam tests

Electronic calibration of the ATLAS LAr calorimeter and commissioning with cosmic muon signals

Muon reconstruction performance in ATLAS at Run-2

The ATLAS Liquid Argon Calorimeter: Construction, Integration, Commissioning Ph. Schwemling on behalf of the ATLAS LAr Group

2 ATLAS operations and data taking

Commissioning of the ATLAS LAr Calorimeter

Les Premières Données dans ATLAS et le Calorimètre à Argon Liquide

PERFORMANCE OF THE ATLAS LIQUID ARGON FORWARD CALORIMETER IN BEAM TESTS

Status Report of the ATLAS Tile Calorimeter

Calibration of the CMS Electromagnetic Calorimeter with first LHC data

Non-collision Background Monitoring Using the Semi-Conductor Tracker of ATLAS at LHC

READINESS OF THE CMS DETECTOR FOR FIRST DATA

Studies of the ATLAS hadronic Calorimeter response to muons at Test Beams

The Compact Muon Solenoid Experiment. Conference Report. Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland. Commissioning of the CMS Detector

PERFORMANCE OF THE ATLAS MUON TRIGGER IN RUN 2

Performance of muon and tau identification at ATLAS

Status of ATLAS and Preparation for the Pb-Pb Run

ATLAS jet and missing energy reconstruction, calibration and performance in LHC Run-2

Upgrade of ATLAS and CMS for High Luminosity LHC: Detector performance and Physics potential

Luminosity determination in pp collisions using the ATLAS detector at the LHC

Upgrade plans for the ATLAS Forward Calorimeter at the HL-LHC

ATLAS EXPERIMENT : HOW THE DATA FLOWS. (Trigger, Computing, and Data Analysis)

arxiv: v2 [nucl-ex] 6 Oct 2008

PoS(DIS 2010)058. ATLAS Forward Detectors. Andrew Brandt University of Texas, Arlington

Jet Reconstruction and Energy Scale Determination in ATLAS

2008 JINST 3 S Outlook. Chapter 11

ATLAS Overview - Sub-detector Performance, Data Taking 2010, Highlights of Latest Results

The ATLAS Detector at the LHC

The ATLAS trigger - commissioning with cosmic rays

Physics potential of ATLAS upgrades at HL-LHC

October 4, :33 ws-rv9x6 Book Title main page 1. Chapter 1. Measurement of Minimum Bias Observables with ATLAS

Measurement of the associated production of direct photons and jets with the Atlas experiment at LHC. Michele Cascella

CALICE Test Beam Data and Hadronic Shower Models

Conference Report Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

QCD Studies at LHC with the Atlas detector

Upgrade of the CMS Forward Calorimetry

Tracking properties of the ATLAS Transition Radiation Tracker (TRT)

Neutral particles energy spectra for 900 GeV and 7 TeV p-p collisions, measured by the LHCf experiment

OPERATIONS & PERFORMANCE OF THE ATLAS DETECTOR IN LHC RUN II

PoS(Vertex 2016)004. ATLAS IBL operational experience

5 Hadronic calorimetry

The Fast Interaction Trigger Upgrade for ALICE

The Compact Muon Solenoid Experiment. Conference Report. Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland. First Physics at CMS

HL-LHC Physics with CMS Paolo Giacomelli (INFN Bologna) Plenary ECFA meeting Friday, November 23rd, 2012

Physics at Hadron Colliders

4. LHC experiments Marcello Barisonzi LHC experiments August

Status and Performance of the ATLAS Experiment

ATLAS New Small Wheel Phase I Upgrade: Detector and Electronics Performance Analysis

arxiv: v1 [physics.ins-det] 10 Apr 2013

LHC State of the Art and News

Future prospects for the measurement of direct photons at the LHC

Reconstruction in Collider Experiments (Part IX)

Highlights of top quark measurements in hadronic final states at ATLAS

Jet Energy Calibration. Beate Heinemann University of Liverpool

PoS(EPS-HEP 2013)508. CMS Detector: Performance Results. Speaker. I. Redondo * CIEMAT

The Electromagnetic Calorimeter of the HERA-B Experiment

Atlas Status and Perspectives

Design of the new ATLAS Inner Tracker for the High Luminosity LHC era

Performance and calibration of CASTOR calorimeter at CMS

THE main physics motivation for building the Compact

Recent results on soft QCD topics from ATLAS

Physics studies to define the CMS muon detector upgrade for High-Luminosity LHC

First Run-2 results from ALICE

Search for exotic Higgs-boson decays in events with at least one photon, missing transverse momentum,

Validation of Geant4 Physics Models Using Collision Data from the LHC

Studies on the e + e - spectrum with the first data of the CMS experiment at the Large Hadron Collider

The ATLAS Run 2 Trigger: Design, Menu, Performance and Operational Aspects

Jet reconstruction with first data in ATLAS

PoS(HCP2009)042. Status of the ALICE Experiment. Werner Riegler. For the ALICE Collaboration. CERN

CMS ECAL status and performance with the first LHC collisions

LHCb Calorimetry Impact

Identification of the Higgs boson produced in association with top quark pairs in proton-proton

Performance of the CMS electromagnetic calorimeter during the LHC Run II

Radiation damage in diamond sensors at the CMS experiment of the LHC

arxiv: v1 [physics.ins-det] 3 Dec 2018 Fast Interaction Trigger for the upgrade of the ALICE experiment at CERN: design and performance

The ATLAS muon and tau triggers

The CMS ECAL Laser Monitoring System

Digital Hadron Calorimetry for the Linear Collider using GEM Technology

Particle detection 1

Jet energy measurement in the ATLAS detector

Commissioning and Calibration of the Zero Degree Calorimeters for the ALICE experiment

Hadron Calorimetry at the LHC

Measurement of Jet Energy Scale and Resolution at ATLAS and CMS at s = 8 TeV

Searches for Long-Lived Particles in ATLAS: challenges and opportunities of HL-LHC

Introduction. Tau leptons. SLHC. Summary. Muons. Scott S. Snyder Brookhaven National Laboratory ILC Physics and Detector workshop Snowmass, Aug 2005

Brief Report from the Tevatron. 1 Introduction. Manfred Paulini Lawrence Berkeley National Laboratory Berkeley, California 94720

The ATLAS Detector - Inside Out Julia I. Hofmann

PDF hosted at the Radboud Repository of the Radboud University Nijmegen

Study of the LHC Luminosity at the ATLAS Experiment using Scintillating Counters

Extending the Calibration of the ATLAS Hadronic Calorimeter to High P t Chris Sears, University of Chicago May 16 th, 2002 Advisor: James Pilcher

Identifying Particle Trajectories in CMS using the Long Barrel Geometry

Results from combined CMS-TOTEM data

Early physics with ALICE

Transcription:

Prepared for submission to JINST Calorimetry for the High Energy Frontier -6 October 17 Lyon (France) Calibration and Performance of the ATLAS Tile Calorimeter During the LHC Run Leonor Cerda Alberich, on behalf of the ATLAS Collaboration. Instituto de Fisica Corpuscular, Univ. of Valencia and CSIC (ES). E-mail: leonor.cerda.alberich@cern.ch ATL-TILECAL-PROC-17-3 18 November 17 Abstract: The Tile Calorimeter (TileCal) is the hadronic sampling calorimeter of the ATLAS experiment at the Large Hadron Collider (LHC). TileCal uses iron absorbers and scintillators as active material and it covers the central region η < 1.7. Jointly with the other sub-detectors it is designed for measurements of hadrons, jets, tau-particles and missing transverse energy. It also assists in muon identification. TileCal is regularly monitored and calibrated by several different calibration systems: a Cs radioactive source, a laser light system to check the PMT response, and a charge injection system (CIS) to check the front-end electronics. These calibration systems, in conjunction with data collected during proton-proton collisions, Minimum Bias (MB) events, provide extensive monitoring of the instrument and a means for equalizing the calorimeter response at each stage of the signal propagation. The performance of the calorimeter has been established with cosmic ray muons and the large sample of the proton-proton collisions and compared to Monte Carlo (MC) simulations. The response of high momentum isolated muons is also used to study the energy response at the electromagnetic scale, isolated hadrons are used as a probe of the hadronic response. The calorimeter time resolution is studied with multijet events. A description of the different TileCal calibration systems and the results on the calorimeter performance during the LHC Run are presented. The results on the pile-up noise and response uniformity studies are also discussed.

Contents 1 Introduction 1 Calibration Systems 3 Performance 4 3.1 Monte Carlo developments 5 4 Conclusions 5 1 Introduction The Tile Calorimeter (TileCal) is the central section of the hadronic calorimeter of the ATLAS experiment [1]. Tile Calorimeter [] covers the η < 1.7 region of the detector. It consists of one barrel and two extended barrel sections and surrounds the Liquid Argon (LAr) barrel electromagnetic and endcap hadronic calorimeters, as seen in Figure 1. The Long Barrel (LB) and Extended Barrel (EB) sections roughly correspond to η < 1. and η > 1., respectively. The crack region between the TileCal LB and EB and the LAr electromagnetic barrel and hadronic endcap sections are covered with special cells made by scintillators (E-cells). The TileCal provides important information for reconstruction of hadrons, jets, hadronic decays of Figure 1. A cut-away diagram of the ATLAS inner detector and calorimeter. The Tile Calorimeter consists of one barrel and two extended barrel sections [3]. tau-leptons and missing transverse energy. This sampling calorimeter uses iron plates as absorber and scintillating tiles as active medium. The calorimeter readout is segmented into about 5 cells (longitudinally and transversally), each of them being read by two photomultipliers (PMTs). Only a small number of cells are read by a single PMT. Tile cells and electronics are organised into 4 partitions, LBA and LBC for the A-side and C-side of the barrel region, and separate EBA and EBC partitions in the extended barrel region. Each partition is divided into 64 symmetric φ slices (modules), with 45 instrumented channels in LB modules and 3 channels in EB modules. Both 1

LB and EB have up to three layers: the A-layer being the closest to the beam axis, followed by the B(C) and D-layers. The η and radial structure of the TileCal cells is shown in Figure (left). The E-cells appear in yellow. They cover the gap/crack region with 1. < η < 1.6. They are partly closer to the beam axis than the A-layer cells and are exposed to high radiation. The TileCal has three key elements: the optical part (scintillators and fibers), the PMTs and the read-out electronics. Figure (right) shows a schematic of the assembly of these components. The light is produced in scintillating tiles, collected and routed by WLS fibers and converted into electric currents by the PMTs. Their signal is shaped and amplified with two gains. The sampling and the digitisation is realised by ADCs. Trigger signals are formed by an analogue sum of input signals and sent to the calorimeter trigger system, which also considers input from other calorimeters. During collisions, if an event is selected by the trigger system, the digitised signals are collected and processed by a Read-Out Driver. In parallel to this, integrators measure the integrated current from the PMTs. Photomultiplier Wave-length shifting fiber Scintillator Steel Source tubes Figure. The TileCal cell and scintillator structure, including the so-called E-cells (E1-E4) installed in the gap/crack region, which are highlighted in yellow (left). Schematic of the mechanical assembly and the optical readout of the TileCal (right) [3]. Calibration Systems At each level of the TileCal signal reconstruction there is a dedicated calibration system to monitor the behaviour of the different detector components. Figure 3 shows the different calibration systems along with the paths followed by the signals from different sources. Fast readout is used for physics analyses of collision data. The reconstructed energy of each TileCal channel, E(GeV), is derived from the raw response, A(ADC) as follows, where the different C factors are calibration constants which will be explained in the next paragraphs: E(GeV) = A(ADC) C ADC pc C pc GeV C Cesium C Laser. (.1) The factors can evolve in time because of variations of PMTs high-voltage, PMTs stress induced by high light flux or optics ageing. The calibration systems are used to monitor the stability of these elements and provide corrections for each channel. While C pc GeV was fixed during dedicated test beam campaigns [4], the remaining calibration constants are provided by individual systems during the data taking:

Integrator Readout (Cs & Particles) Particles Calorimeter Tiles Photomultiplier Tubes Digital Readout (Laser & Particles) 137 Cs source Laser light Charge injection (CIS) Figure 3. Flow diagram of the readout signal path of the different TileCal calibration tools. In the text Particles are named MB events. The paths are partially overlapping, allowing for cross-checks and an easier identification of component failures [3]. A moveable Cesium [5] radioactive γ-source to calibrate the optic components and the PMT gains. The channel response to the energy deposits is used to equalise the response of all the cells and maintain global response of the calorimeter at the electromagnetic scale. Deviation of measured Cesium signals from expected values, corrected for the Cesium decay curve, are interpreted as gain variations and translated into calibration constants (C Cesium ). The calibration scans are performed every few months, each scan takes about 8 hours during non-collision time. The measurement precision is better than.3%. Laser system [6] to monitor the PMTs and the electronic components. This system sends a controlled amount of light onto the photocathode of each PMT in the absence of collisions. Deviations of any channel response with respect to its reference response (at the time of the latest Cesium calibration) is then translated into a calibration constant: C Laser. The Laser calibration runs are usually taken twice a week to monitor the individual PMT gain variations between the Cesium scans. Figure 4 shows the mean gain variation per cell type between end of May and end of October, covering most of the proton-proton collisions data taking period. Laser pulses are also sent during empty bunch crossings of the LHC, with a frequency of 4 Hz (1 Hz) during Run (Run 1). The laser system allows also to determine the timing of the signal respect to the proton collision timing. Tile calorimeter Long Barrel D BC A y x 4 PMT gain variation [%] Tile calorimeter Extended Barrel D BC A y x 4 PMT gain variation [%] Run 311556 1 7 8:3:41 Run 311556 1 7 8:3:41 Figure 4. Tile Calorimeter PMT gain variation map during pp collisions period obtained with the laser system. Long Barrel (left) and Extended Barrel (right) [3]. Calibrations of digital gains and linearities with the charge injection system (CIS) [7]. The corresponding calibration runs are taken from daily to weekly, so C ADC pc conversion factors 3

6 Inner Cells A13: 1. < η < 1.3 Gap/Crack Cells 8 1 1 E1: 1. < η < 1.1 E: 1.1 < η < 1. Tile Calorimeter E3: 1. < η < 1.4 Data s = 13 TeV E4: 1.4 < η < 1.6 Total Delivered: 39 fb-1 1 3 1 14 5 1 Tile Calorimeter 35 Data s = 13 TeV 3-1 A13 1. < η < 1.3 inner layer D6 1.1 < η < 1.3 outer layer Total Delivered: 39 fb 5 Laser 6 15 Minimum Bias 8 1 Integrated Charge [mc] 1 Cesium Scan 9/4 9/5 Total Integrated Delivered Luminosity [pb-1] A13/D6 Average response [%] Scintillator Irradiation Effect [%] can be regularly produced and applied to data. The overall stability of the calibration factor is at the level of.% and usually less than 1% of the channels exhibit large fluctuations. CIS calibration constants are updated if the deviation from the previous measured value is above the CIS systematic error (.7%). Monitoring of TileCal optics with the integrator system minimum bias (MB). Both the Minimum Bias and the Cesium systems measure the signal coming from scintillators and the variation in PMT response over time. Thus, they are expected to give similar results. The Laser system measures only the PMT gain drifts in time. The variations observed by the MB and Cesium systems are sensitive to PMT gain drift and scintillator irradiation (ageing). Thus, the difference between MB, or Cesium, and the Laser measurements can be interpreted as a loss of efficiency of the scintillators by irradiation damage. The cell probed in Figure 5 (left), A13, is the most irradiated cell in TileCal, excluding the E-cells. The MB system allows also to determine the variation of the LHC luminosity [8]. Figure 5 (right) shows the response variation measured by the MB and the Laser system for E-cells, covering the region (1. < η < 1.3) as a function of time. The integrated luminosity evolution during the same period is also shown in the plot. 5 8/6 8/7 7/8 6/9 6/1 Time [dd/mm and year] Figure 5. The relative response variation measured by the MB system, after the subtraction of the PMT gain drift component measured by the Laser system, as a function of the integrated charge collected in the cells in the gap/crack region in the EB, covering the region (1. < η < 1.6) and in the cells in the inner layer of the EB, covering the region (1. < η < 1.3), during the pp collisions data taking periods (left) and the Tile Calorimeter response variation in time measured by the MB and the Laser system for E-cells during pp collisions data taking periods (right) [3]. 3 Performance To maintain the smallest possible number of dead cells and to ensure the highest quality of the data, the front-end electronics, normally not accessible during data taking, is maintained yearly during detector openings. During the winter shutdown of 17, 48 out of 56 electronics drawers were opened and all the high and many of the low priority problems were fixed, leading to the.6% of dead cells after the end of the maintenance. The ever-increasing instantaneous luminosity of the LHC led to the increase of the pile-up and hence to the increase of the noise levels, well above the pure electronics noise that stays below 4

MeV for most of the cells, while the pile-up noise reached 16 MeV for the inner layer of the calorimeter cells. The cell signal timing is determined with a precision better than 1 ns using collision events (see Figure 6, left). The timing is initially set with splashes and tuned later with jets. The stability of the time settings during the data taking is monitored with the laser pulses in empty bunches of LHC abort gap, described above. The ratio of energy deposited in TileCal to track momentum (E/p) for isolated charged hadrons in minimum bias events is used to evaluate calorimeter uniformity and linearity during data taking. The data and simulation do agree, showing linearity and uniformity in detector response. The de/dx of minimum ionising particles show data and Monte Carlo (MC) agreement within 4% (see Figure 6, right). Muons from cosmic rays, beam halo and collisions are used to study in-situ the electromagnetic energy scale. A 1% (3%) response non-uniformity in η is seen in Tile Calorimeter Long (Extended) Barrel. The energy scale is set with a precision of 3%. Cell time resolution [ns] 4.5 4 3.5 3.5 1.5 high gain p.715 ±.3 p1 1.65 ±.3 p 1.38 ±.4 Tile Calorimeter s = 13 TeV, 5 ns low gain p.316 ±.3 p1.6 ±.4 p 13.3 ±.18 p 1 σ = p + E p + E 1.5 4 6 8 1 Cell energy [GeV] Figure 6. The cell time resolution in jet events as a function of the energy deposited in Long Barrel cells of the Tile Calorimeter (left) and calorimeter response to single isolated charged hadrons, characterised by energy over momentum (E/p), as a function of η (right) [3]. 3.1 Monte Carlo developments The response of the PMTs is not flat in the azimuthal angle difference between the energy deposition point and the center of the cell ( φ), but it shows a non-negligible dependence referred to as U- shape. The dependence of the response on φ was measured using W µν events in the 1 collisions data. The measurement is performed separately in the Long Barrel and in the Extended Barrels in each radial layer. The typical shape is shown in Figure 7 (left) for the Long Barrel. The U-shape has been implemented in the MC simulations and is expected to improve the light propagation performance in future official productions. Figure 7 (right) shows the comparison between simulations with and without U-shape for the layer A in the Long Barrel. 4 Conclusions The hadronic Tile Calorimeter allows to measure jet energy and missing transverse energy in ATLAS experiment at the LHC. A set of calibration systems is used to monitor and calibrate the 5

Figure 7. Response dependence on the azimuthal angle difference between the muon track impact point and the center of the cell ( φ) measured in 1 collisions data (left) and for MC (right). Look-up tables are prepared based on measurements in data and normalized as follows: First, average value for one PMT is set to.5. Second, the look-up tables are rescaled to have the same sampling fraction for 1 GeV electrons at η =.35 in the center of the cell as the simulations without the U-shape [3]. calorimeter response with better than 1% precision. The electromagnetic energy scale allows to achieve a great performance of Tile Calorimeter in LHC Run with 3% precision. Acknowledgments This work is partially supported by the Spanish Ministry of Economy, Industry and Competitiveness and the European Regional Development Fund (ERDF), contract number FPA15-6565-C4--R (MINECO/FEDER). References [1] ATLAS Collaboration, The ATLAS Experiment at the CERN Large Hadron Collider, Journal of Instrumentation 3 S83, 8. [] ATLAS Collaboration, Readiness of the ATLAS Tile Calorimeter for LHC collisions, Eur. Phys. J. C7: 1193-136, 1. [3] ATLAS Collaboration, https://twiki.cern.ch/twiki/bin/view/atlaspublic/approvedplotstile. [4] P. Adragna et al., Testbeam studies of production modules of the ATLAS Tile Calorimeter, Nucl. Instrum. Meth. A 66 (9) 36. [5] E. Starchenko et al., Cesium monitoring system for ATLAS Tile Hadron Calorimeter, Nucl. Instrum. Meth. A 494 () 381. [6] ATLAS Tile Calorimeter system, The Laser calibration of the Atlas Tile Calorimeter during the LHC run 1, JINST 11 T15,. [7] K. Anderson et al., Design of the front-end analog electronics for the ATLAS Tile Calorimeter, Nucl. Instrum. Meth. A (5) 469. [8] ATLAS Collaboration, Improved luminosity determination in pp collisions at s = 7 TeV using the ATLAS detector at the LHC, Eur. Phys. J. C 73 (13) 518. 6