EVALUATION OF THE ENVIRONMENTAL EFFECTS ON A MEDIUM RISE BUILDING

Similar documents
Non-damage Modal Parameter Variations on a 22 Story Reinforced Concrete Building

EXPERIMENTAL EVALUATION OF MODAL PARAMETER VARIATIONS FOR STRUCTURAL HEALTH MONITORING

VIBRATION-BASED DAMAGE DETECTION UNDER CHANGING ENVIRONMENTAL CONDITIONS

The effect of environmental and operational variabilities on damage detection in wind turbine blades

Dynamic Properties of a Tall Reinforced Concrete Tower with Tuned Liquid Dampers

SYSTEM IDENTIFICATION & DAMAGE ASSESSMENT OF STRUCTURES USING OPTICAL TRACKER ARRAY DATA

STRUCTURAL HEALTH MONITORING OF TORRE CENTRAL BY THE WAVE METHOD

10. FIELD APPLICATION: 1D SOIL MOISTURE PROFILE ESTIMATION

Investigation of traffic-induced floor vibrations in a building

Données, SHM et analyse statistique

SHAKING TABLE TEST OF STEEL FRAME STRUCTURES SUBJECTED TO NEAR-FAULT GROUND MOTIONS

Figure 1. Daily variation of air temperature

CSCE 2011 General Conference - Congrès générale 2011 de la SCGC. Ottawa, Ontario June 14-17, 2011 / 14 au 17 juin 2011

Mode Identifiability of a Multi-Span Cable-Stayed Bridge Utilizing Stochastic Subspace Identification

EFFECT OF A DAMAGE TO MODAL PARAMETERS OF A WIND TURBINE BLADE

Comparative analysis of data collected by installed automated meteorological stations and manual data in Central Asia.

UWM Field Station meteorological data

WYANDOTTE MUNICIPAL SERVICES COMMUNITY WIND ENERGY PROJECT WIND RESOUCE SUMMARY

PRELIMINARY STUDY OF GROUND MOTION CHARACTERISTICS IN FURUKAWA DISTRICT, JAPAN, BASED ON VERY DENSE SEISMIC-ARRAY-OBSERVATION

Development of Innovative Technology to Provide Low-Cost Surface Atmospheric Observations in Data-sparse Regions

MODAL IDENTIFICATION AND DAMAGE DETECTION ON A CONCRETE HIGHWAY BRIDGE BY FREQUENCY DOMAIN DECOMPOSITION

SU solar resource measurement station: Sonbesie metadata

Dimensionality Reduction: PCA. Nicholas Ruozzi University of Texas at Dallas

Monthly Magnetic Bulletin

AUTOMATED BUILDING DETECTION FROM HIGH-RESOLUTION SATELLITE IMAGE FOR UPDATING GIS BUILDING INVENTORY DATA

The Principal Component Analysis

SOUTH MOUNTAIN WEATHER STATION: REPORT FOR QUARTER 2 (APRIL JUNE) 2011

ON-LINE SOLAR RADIATION MONITORING SYSTEM, IN CLUJ NAPOCA, ROMANIA

Damage detection using output-only measurement by indirect approach

Optimal sensor placement for detection of non-linear structural behavior

Study on Evolutionary Modal Parameters of Runyang Suspension Bridge during Typhoon Matsa

University of California

Operational modal analysis using forced excitation and input-output autoregressive coefficients

FREQUENCIES AND DAMPING RATIOS OF A HIGH RISE BUILDING BASED ON MICROTREMOR MEASUREMENT

Damage detection of truss bridge via vibration data using TPC technique

Monthly Magnetic Bulletin

Unsupervised Learning Methods

Vibration-based SHM for cultural heritage preservation: the case of the S. Pietro bell-tower in Perugia

Communicating Climate Change Consequences for Land Use

Damping Estimation Using Free Decays and Ambient Vibration Tests Magalhães, Filipe; Brincker, Rune; Cunha, Álvaro

Wind Resource Data Summary Cotal Area, Guam Data Summary and Transmittal for December 2011

IOMAC' May Guimarães - Portugal RELATIONSHIP BETWEEN DAMAGE AND CHANGE IN DYNAMIC CHARACTERISTICS OF AN EXISTING BRIDGE

REAL-TIME ASSESSMENT OF EARTHQUAKE DISASTER IN YOKOHAMA BASED ON DENSE STRONG-MOTION NETWORK

Wave Dispersion in High-Rise Buildings due to Soil-Structure Interaction ABSTRACT

Weather Stations. Evaluation copy. 9. Post live weather data on the school s web site for students, faculty and community.

Uncertainty analysis of system identification results obtained for a seven-story building slice tested on the UCSD-NEES shake table

13 SHADOW FLICKER Introduction Methodology

WEATHER STATION FOR SOLAR FARM MONITORING

Effects of climate change on landslide frequencies in landslide prone districts in Sri Lanka; Overview

The Climate of Texas County

NEGST. New generation of solar thermal systems. Advanced applications ENEA. Comparison of solar cooling technologies. Vincenzo Sabatelli

The science of learning from data.

Introduction to Machine Learning

EXPERIMENTAL STUDY ON CONCRETE BOX GIRDER BRIDGE UNDER TRAFFIC INDUCED VIBRATION

2000 LOCAL CLIMATOLOGICAL DATA Annual Summary with Comparative Data

USE OF AMBIENT VIBRATION TESTS FOR STRUCTURAL IDENTIFICATION: 3 CASES STUDIES

CONTRIBUTION TO THE IDENTIFICATION OF THE DYNAMIC BEHAVIOUR OF FLOATING HARBOUR SYSTEMS USING FREQUENCY DOMAIN DECOMPOSITION

The Climate of Pontotoc County

Technical note on seasonal adjustment for M0

OMA Research of Sky Tower in Wrocław, Poland

A TEST OF THE PRECIPITATION AMOUNT AND INTENSITY MEASUREMENTS WITH THE OTT PLUVIO

Cyclic fatigue demands on structures subjected to the Canterbury Earthquake Sequence

Evidence of Soil-Structure Interaction from Ambient Vibrations - Consequences on Design Spectra

Evaluation of data-driven methods for damage detection under environmental effects application to a cable-stayed bridge

The Climate of Haskell County

APPENDIX 3.6-A Support Information for Newcastle, Wyoming Meteorological Monitoring Site

Damage detection in a reinforced concrete slab using outlier analysis

The Climate of Payne County

Quality assurance for sensors at the Deutscher Wetterdienst (DWD)

Innovative Sustainable Technology

Memo. I. Executive Summary. II. ALERT Data Source. III. General System-Wide Reporting Summary. Date: January 26, 2009 To: From: Subject:

The Climate of Murray County

Codal Provisions IS 1893 (Part 1) 2002

Increasing Transmission Capacities with Dynamic Monitoring Systems

PRECIPITATION TYPE AND RAINFALL INTENSITY FROM THE PLUDIX DISDROMETER DURING THE WASSERKUPPE CAMPAIGN

ANALYSIS OF HIGHRISE BUILDING STRUCTURE WITH SETBACK SUBJECT TO EARTHQUAKE GROUND MOTIONS

Monthly Magnetic Bulletin

Monthly Magnetic Bulletin

Jayalath Ekanayake Jonas Tappolet Harald Gall Abraham Bernstein. Time variance and defect prediction in software projects: additional figures

A Preliminary Analysis on the Statistics of about One-Year Air Gap Measurement for a Semi-submersible in South China Sea

Monthly Magnetic Bulletin

Effects of wind and traffic excitation on the mode identifiability of a cable-stayed bridge

Modal System Identification & Finite Element Model Updating of a 15-story Building using Earthquake & Ambient Vibration Data

The Climate of Marshall County

The Climate of Bryan County

Quality assurance for sensors at the Deutscher Wetterdienst (DWD)

KING EDWARD POINT OBSERVATORY MAGNETIC DATA

KING EDWARD POINT OBSERVATORY MAGNETIC DATA

Surface Anomalies Prior to Earthquakes

Movement assessment of a cable-stayed bridge tower based on integrated GPS and accelerometer observations

Computing & Telecommunications Services

Seismic response of SDOF systems under doublet earthquakes. *Saman Yaghmaei-Sabegh 1)

Environmental Effects on the Identified Natural Frequencies of the Dowling Hall Footbridge

Computing & Telecommunications Services Monthly Report January CaTS Help Desk. Wright State University (937)

System Identification and Model Updating of the Four Seasons Building

Jackson County 2013 Weather Data

Technical note on seasonal adjustment for Capital goods imports

KING EDWARD POINT OBSERVATORY MAGNETIC DATA

Zero-Pad Effects on Conditional Simulation and Application of Spatially-Varying Earthquake Motions

Geotechnical Earthquake Engineering

Transcription:

7th European Workshop on Structural Health Monitoring July 8-11, 214. La Cité, Nantes, France More Info at Open Access Database www.ndt.net/?id=17121 EVALUATION OF THE ENVIRONMENTAL EFFECTS ON A MEDIUM RISE BUILDING Ruben Boroschek 1, Felipe Tamayo 2, Rafael Aguilar 3 1 Civil Engineering Department, University of Chile 2 Student, Civil Engineering Department, University of Chile. 3 Civil Engineering Department, Pontifical University of Peru. rborosch@ing.uchile.cl ABSTRACT This article presents the variation of the dynamics properties due to environmental effects of the Central Tower at the Faculty of Physical and Mathematical Science of the University of Chile. This structure is a nine story, shear wall reinforced concrete building, 3 meters high, which has been monitored automatically and remotely since 29 with a network of 8 uniaxial accelerometers and 9 environmental sensors. The network registers the ambient conditions, such as wind speed and direction, temperature, radiation, rainfall, ambient and soil humidity. The range of variation on environmental effect and modal properties is presented. Detailed analysis of the temperature effect on the properties is presented. The Principal Component Analysis (PCA) methodology has been utilized to reduce some environmental effects on the vibration frequencies to identify earthquake damage in the structure. The advantages and disadvantages of the method are presented. Typical variations in the range of 4% are observed related to temperature and 6% related to the rain and the surrounding soil humidity. Earthquake damage during the 21 Mw=8.8 Earthquake is clearly identify from ambient vibration and earthquake records. Damage is considered low, with some visible cracking in structural wall. Variations due to this damage are in the order for 15 to 2% for predominant natural frequencies. KEYWORDS : shm, ambient vibrations, temperature, rain, damping, identification 1 BUILDING DESCRIPTION The instrumented building called Central Tower was constructed in 1962. It is located at the Engineering Faculty of the University of Chile and is used for office and classroom. It has 9 stories above ground and 2 underground levels. It has a total surface of 4,6 m2, approximately. It has a total height of 3.2 meters and a plan area of 3 x 19 meters, Figure 1. The structural system consists on a reinforced concrete shear and gravity walls. Typical wall thickness is 35 cm and typical slab thickness is 25 cm. The typical ratio between total wall area to plan area is 7.7 %. The building is instrumented with an array of 8 uniaxial accelerometers that allows the continuous recording of the structural response due to ambient vibrations and seismic events. Furthermore, it has 9 environmental sensors which detect and save the data obtained from ambient conditions, such as speed and direction, temperature, rainfall, etc. [1]. 2 AMBIENT CONDITIONS SENSORS DESCRIPTION Nine environmental sensors register the ambient conditions continuously: wind speed and direction, temperature, radiation, rainfall, ambient and soil humidity, and air pressure. The meteorological conditions are recorded by a meteorological station (Figure 2 (c)) that reports data every 15 minutes (the reported value corresponds to the mean of the data acquired in the previous 15 minutes). The meteorological station is installed on the roof of the Civil Engineering and Geophysics building, which is next to the Central Tower building, and it is maintained by the Meteorology Group of the Copyright Inria (214) 291

Department of Geophysics at the University of Chile. The humidity sensors have been installed in a borehole in the west side of the building (Figure 2 (a) and (b)). The humidity sensors are located at 2, 1 and 5 meters below the surface and they are connected to the accelerometers data acquisition system. The description of the sensors is shown in the Table 1. Figure 1: Central Tower - General Views. Figure 2 : Sensors: (a) schematic well location, (b) well, humidity sensors and (c) meterological station. Table 1: Meteorological Station Instruments and Soil Saturation Sensors Variable Instrument Model / Brand Air Temperature ( C) Solid state hygrothermometer CS-5, Campbell Sci. Relative Humidity (%) Solid state hygrothermometer CS-5, Campbell Sci. Solar Radiation (W/m 2 ) Silicon pyranometer LI2X, Campbell Sci. Air Pressure (hpa) Solid state barometer PTA-127, Vaisala. Rainfall (mm) Scales pluviometer TE525mm, Texas Instruments Wind (magnitude in m/s, direction in degrees) Anenometer + weather vaine 31 Wind Sentry Wind Set, Young. Soil Saturation (%) Moisture Probe MP46, ICT International 292

3 VARIATION OF MODAL PROPERTIES DUE TO ENVIRONMENTAL EFFECT Natural frequencies are derived from acceleration automatically. The data span a period of 2 years and 6 months, from June 24 th of 29 to December 31th of 211. The frequencies were obtained through the application of the SSI_COV identification method, which was applied on acceleration data every 15 minutes [2]. The results for the first three frequencies are presented in Figure 3 in terms of time series. Also, the same results are shown in the histograms presented in Figure 4, before and after the 8.8 Mw Earthquake, which produced slight damage. 3.2 3 2.8 Central Tower Frequencies - SSI Period without data due to failure in data acquisition system f 1 f 2 f 3 Frequency [Hz] 2.6 2.4 2.2 2 Frequency change due to 8.8 Mw 21 Earthquake 1.8 Jun9 Sep9 Dec9 Mar1 Jun1 Sep1 Dec1 Mar11 Jun11 Sep11 Dec11 Time [Month/Year] Figure 3: Central Tower Frequencies - SSI Additionally in Figure 5 histograms show the full range of data after the earthquake, and a set of filtered data. For the filtered data histograms we have removed the effects of the responses of the structure under seismic events (approximately 17 events), periods of high humidity in the ground and for which we have selected only the natural frequencies when the external temperature is in the range of 2.5 C and 21.5 C. The effect of amplitude of response, temperature and soil humidity can be observed as a change in the median frequency and the standard deviation of the frequency histogram. The mean frequency decreased.7%,.6% and.7% while the standard deviation decreased 23%, 12% and 17% for frequencies 1, 2 and 3 respectively. Also the histogram changes from bimodal to a unimodal shape. 293

5 Frequency histograms - Central Tower Building f 1 1.8 1.9 2 2.1 2.2 2.3 Before 8.8Mw mean: 2.236 std:.23 After 8.8Mw mean: 1.96 std:.22 Number of Observations 5 f 2 2.3 2.4 2.5 2.6 2.7 Before 8.8Mw mean: 2.622 std:.19 After 8.8Mw mean: 2.318 std:.25 2 2.6 2.7 2.8 2.9 3 Frecuency [Hz] f 3 Before 8.8Mw mean: 2.977 std:.27 After 8.8Mw mean: 2.731 std:.36 Figure 4: Frequency histograms, before and after 8.8 Mw Earthquake. Central Tower Building. 4 PRINCIPAL COMPONENT ANALYSIS Principal Component Analysis (PCA) is a statistical tool commonly used to reduce the dimension of a data set, replacing a group of related variables by a new smaller group of independent variables, which are designated as principal components. Consider a matrix, where each row corresponds to a variable, and each column corresponds to the measurement of that variable at each instant of time. The original variables stored in the matrix can be transformed into a set of variables through the following equation: = (1) Where, with is an orthogonal matrix (its inverse coincides with its transpose) which applies a rotation to the original coordinate system. The object of PCA is to find a transformation that leads to a set of variables (principal components) which are independent of each other, so that the covariance matrix of is diagonal, and also the variance of to decreases from to. Thus, the first principal component,, explains the largest proportion of the variance of the original variables, while the last principal components explains a smaller proportion of the variance. 294

1 Frequency 1.8.6.4.2 Unfiltered data mean: 1.96 std:.22 Filtered data mean: 1.892 std:.17 1.82 1.84 1.86 1.88 1.9 1.92 1.94 1.96 1.98 2 Number of Observations 1.8.6.4.2 Frequency 2 2.22 2.24 2.26 2.28 2.3 2.32 2.34 2.36 2.38 2.4 Unfiltered data mean: 2.318 std:.25 Filtered data mean: 2.34 std:.22 1 Frequency 3.8.6.4.2 Unfiltered data mean: 2.731 std:.36 Filtered data mean: 2.711 std:.3 2.64 2.66 2.68 2.7 2.72 2.74 2.76 2.78 2.8 2.82 Frequency [Hz] Figure 5: Normalized frequency histograms after 8.8 Mw Earthquake. Blue lines correspond to raw data and red lines corresponds to filtered data in the range 2.5 C and 21.5 C, and removing rain and earthquakes effects. Considering the relation between and given in equation (1), and taking into account the orthogonality of, the covariance matrix of designated by can be related to the covariance matrix of designated by Λ through the following expression: Σ = = = Λ (2) And since the singular value decomposition gives: Σ = (3) The matrices obtained by the SVD decomposition can be used to obtain the transformation matrix = and the variances of the components of (diagonal elements of the matrix ). The main feature of the method is the possibility to determine principal components explaining a greater or lesser extent the variability of the measured variables. Since the algorithms that perform the singular value decomposition SVD delivers singular values in decreasing order, the first diagonal element of matches with the variance of, while the rest of the singular values decrease, as well as the variances of the components of. Thus, it is possible to divide the matrix into two parts: =!,! #,,! % & and # =! %',! %'#,,! &, where is a diagonal matrix containing the first ( singular values, and a diagonal matrix containing the rest of the singular values, which are not relevant to explain the variability of the components of. A way to determine the value of ( is through the determination of the following equation: 295

) = -,./ +,,./ +, (4) This ratio determines the percentage of variance of observed data that is represented by the ( first components of. In this way, it is possible to determine ( defining a minimum value for ), for example.95. Once ( is selected, the set of variables to % can be calculated using equation (1), using a matrix 1 constructed from the first ( columns of. After reducing the dimension of the set of original variables through the 1 matrix, it is possible to reallocate the variables to its original space. Thus we have: 1 = 1 1 (5) Where 1 corresponds to the modified original variables, which retain the variation due to factors that produce more variance in the original data, discarding the factors that produce little variability in these, which in the event that the measured variables are, for example, frequencies in a structure, may correspond to measurement errors or structural damage. Once the modified variables are calculated, the residual error matrix can be obtained as follows: 2 = 1 (6) From the prediction error vector 2 obtained at time, the Novelty Index (NI) is defined using the Euclidean norm : 4) 5 = 2 (7) Defining 4) and 7 as the mean value and the standard deviation of NI obtained in the reference state, a control chart is constructed by drawing a centerline (CL) at 4) and two additional horizontal lines corresponding to the upper and lower limits (UCL and LCL) : 89 = 4) (8) 89 = 4) +;7 (9) 989 = 4) ;7 (1) Where coefficient ; is taken equal to 3, which corresponds to a confidence interval of 99.7% with the assumption of a normal distribution. In the absence of damage, the Novelty Index should lie between the UCL and LCL limits, and if structural damage occurs the NI value should fall outside the control chart limits [3]. 4.1 PCA analysis on frequency series of the Central Tower Building To evaluate the effect of PCA on a real structure, two analyses have been made that demonstrate its benefit in certain scenarios. The first analysis is shown in Figure 6, in which PCA is applied before the 8.8 Mw earthquake, with a training time of 7 months. This is all the data before the damaging earthquake. It can be seen that the slight damage due to the earthquake is clearly identified with the drop of the novelty index below the LCL limit. The second analysis is shown in Figure 7, in which PCA is applied after the earthquake, with a training time of 12 months. After the period of training it can be seen that despite the fact that there 296

was not strong shaking in the subsequent period or an event that may suppose that have been damage on the structure, there is some data in the control chart that overpass the upper and lower limits. The number of data in the control chart that overpass the limits is 3, and if we apply PCA to the frequency record but extracting from the frequency series, the data influenced by earthquakes occurred on that period, we find out that the number of data that overpass the limit is 24, meaning that the effect of low intensity earthquakes in the false positives on PCA is relatively small. Other effects that may influence the effectiveness of PCA is the quality of the identification process, which could be responsible for a negative result in the control charts and the duration of the training phase. 3.2 Central Tower Frequencies - SSI 3 f 1 f 2 f 3 2.8 Frequency [Hz] 2.6 2.4 2.2 2 1.8 Jun9 Sep9 Dec9 Mar1 Jun1 Sep1 Dec1 Mar11 Jun11 Sep11 Dec11 Time [Month/Year].4865 Control Chart - Central Tower Index UCL LCL CL Novelty Index.3775.2685 Jun9 Sep9 Dec9 Mar1 Jun1 Sep1 Dec1 Mar11 Jun11 Sep11 Dec11 Time [month/year] Figure 6: PCA analysis before 8.8 Mw Earthquake. Dotted line on control chart corresponds to the training time CONCLUSION The variations of the dynamics properties due to environmental effects of the Central Tower at the Faculty of Physical and Mathematical Science of the University of Chile have been studied. Over 9, ambient vibrations records and over 1,7 seismic records have been analyzed, combined with the environmental records obtained from a meteorological station. Significant reduction of the variance of the frequencies has been obtained when removing data affected by rain, earthquakes and filtering by temperature in the range 2.5 C - 21.5 C. 297

PCA has been used to identify damage on the structure before and after the 8.8 Mw Earthquake. The results show that the damage due to the 8.8 Mw Earthquake has been clearly identified. False positives have been obtained when applying PCA after the earthquake, which are slightly reduced if the effects of seismic events are eliminated. This negative result may be influenced by the quality of the identification process or by events of rain due to the limitations of the method or training period to capture its effects. This situation is part of an ongoing research 3 Central Tower Frequencies - SSI 2.8 f 1 f 2 f 3 Frequency [Hz] 2.6 2.4 2.2 2 1.8 Mar1 May1 Aug1 Nov1 Feb11 May11 Aug11 Nov11 Time [Month/Year].2 Control Chart - Central Tower Index UCL LCL CL Novelty Index.1396.792 Mar1 May1 Aug1 Nov1 Feb11 May11 Aug11 Nov11 Time [month/year] Figure 7: PCA analysis after 8.8 Mw Earthquake. Dotted line on control chart corresponds to the training time REFERENCES [1] Boroschek R., Aguilar A., Basoalto J., León P. (213) Structural Health Monitoring of a Mid Height Building in Chile, 5 th International Operational Modal Analysis Conference, Guimarães, Portugal. [2] Basoalto J. (213) Análisis del efecto de las condiciones ambientales en las propiedades modales de un edificio de hormigón armado, Thesis in fulfillment of the requirements for the degree of Civil Engineer, Universidad de Chile. [3] Yan, A. -M., Kerschen, G., De Boe, P. and Golinval, J. -C. [25] Structural damage diagnosis under varying environmental conditions-part I: A linear analysis. Mechanical Systems and Signal Processing, 19 (25) 847-864. 298