Elemental Scientific. Spike Recovery. Elemental Scientific

Similar documents
Elemental Scientific. Spike Recovery. Elemental Scientific

Elemental Scientific. Stability. Elemental Scientific

Using cold vapor generation atomic absorption to determine mercury impurities in pharmaceutical products

Key Analytical Issues: Sample Preparation, Interferences and Variability. Tim Shelbourn, Eli Lilly and Company

Automated, intelligent sample preparation: Integration of the ESI prepfast Auto-dilution System with the Thermo Scientific icap 7400 ICP-OES

High Throughput Water Analysis using Agilent 7900 ICP-MS coupled with ESI prepfast

Validating performance of an Agilent 7800 ICP MS for USP <232>/<233> & ICH Q3D/Q2(R1): Elemental Impurity Analysis in Pharmaceuticals

Determination of Chromium in Gelatin Capsules using an Agilent 7700x ICP-MS

Automated Determination of PPQ Levels of Thorium in High Purity Copper

High-Speed Environmental Analysis Using the Agilent 7500cx with Integrated Sample Introduction System Discrete Sampling (ISIS DS)

Samples compliant with the WATER

Analysis of high matrix samples using argon gas dilution with the Thermo Scientific icap RQ ICP-MS

Authors: C. Derrick Quarles, Jr. *, Patrick Sullivan, M. Paul Field, Hwan Kim, and Daniel R. Wiederin

Total Elemental Analysis of Food Samples for Routine and Research Laboratories, using the Thermo Scientific icap RQ ICP-MS

Enhancing the productivity of food sample analysis with the Agilent 7700x ICP-MS

The Agilent 7700x ICP-MS Advantage for Drinking Water Analysis

á233ñ ELEMENTAL IMPURITIES PROCEDURES

Direct Measurement of Metallic Impurities in 20% Ammonium Hydroxide by 7700s/7900 ICP-MS

Thermo Scientific icap RQ ICP-MS: Typical limits of detection

RISK ASSESSMENT, IMPLEMENTATION AND VALIDATION OF ELEMENTAL IMPURITIES FOR ICH Q3D, USP <232><233> AND EP 5.20

Concept of Elemental Impurities (EI) assessment in finished dosage forms by total extraction testing

Simple and Reliable Soil Analysis using the Agilent 7800 ICP-MS with ISIS 3

Multi-Element Analysis of Cannabis using the Agilent 7800 ICP-MS

ICP/MS Multi-Element Standards

Fundamentals of the ICP-MS Technique and How to Resolve Issues for Pharmaceutical Materials (In 20 Minutes) Tim Shelbourn, Eli Lilly and Company

7) Applications of Nuclear Radiation in Science and Technique (1) Analytical applications (Radiometric titration)

Application of the Agilent 7900 ICP-MS with Method Automation function for the routine determination of trace metallic components in food CRMs

Analysis of domestic sludge using the Agilent 4200 MP-AES

Trace Analyses in Metal Matrices Using the ELAN DRC II

Total elemental analysis of food samples for routine and research laboratories using the Thermo Scientific icap RQ ICP-MS

Automating Sample Purification MC-ICPMS. Elemental Scientific ICP ICPMS AA

Multi Analyte Custom Grade Solution. Aluminum, Potassium, Magnesium, ANALYTE CERTIFIED VALUE ANALYTE CERTIFIED VALUE

Direct Analysis of Trace Metal Impurities in High Purity Nitric Acid Using ICP-QQQ

China Soil Pollution Survey: Elemental Analysis of Soil and Sediment Digests by ICP-MS

Element Cube Project (x2)

1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

Simple, reliable analysis of high matrix samples according to US EPA Method 6020A using the Agilent 7700x/7800 ICP-MS

Examples of Method Validation Studies Conducted in Different Economies

Three hour lab. Chem : Feb Experiment 2 Session 2. Experiment 2 Session 2 Electrons and Solution Color

The Determination of Toxic, Trace, and Essential Elements in Food Matrices using THGA Coupled with Longitudinal Zeeman Background Correction

February 20, Joe Cerniglia The International Group for Historic Aircraft Recovery (TIGHAR) Job Number: S0CHG688. Dear Joe:

ELEMENTAL ANALYSIS OF GLASS EXAMINATIONS (PART 1) Module 4

Determination of Impurities in Silica Wafers with the NexION 300S/350S ICP-MS

E5 Lewis Acids and Bases: lab 2. Session two lab Parts 2B, 3, and 4. Session one lab Parts 1and 2A. Aquo Complex Ions

Single Analyte Mass Spec Solution ± µg/ml g/ml (measured at 20 ± 1 ºC) METHOD NIST SRM# SRM LOT#

Traceability, validation and measurement uncertainty 3 pillars for quality of measurement results. David MILDE

Application. Determination of Trace Metal Impurities in Semiconductor-Grade Hydrofluoric Acid. Authors. Introduction. Abstract.

1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

Proposed new USP general chapters <232> and <233> for elemental impurities: The application of ICP-MS for pharmaceutical analysis

Trace elemental analysis of distilled alcoholic beverages using the Agilent 7700x ICP-MS with octopole collision/ reaction cell

E5 Lewis Acids and Bases: lab 2. Session two lab Parts 2B, 3, and 4. Session one lab Parts 1and 2A. Aquo Complex Ions. Aquo Complex Ion Reactions

1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

Determination of trace elements in ultrapure semiconductor grade sulfuric acid using the Agilent 8900 ICP-QQQ in MS/MS mode

Faculty of Natural and Agricultural Sciences Chemistry Department. Semester Test 1. Analytical Chemistry CMY 283. Time: 120 min Marks: 100 Pages: 6

PQRI Technical Analytical Challenges Round 2 Interlaboratory Study: Progress and Early Findings

ICH Q3D: Practical implementation and the role of excipient data in a risk based approach. Dr Andrew Teasdale

(C) Pavel Sedach and Prep101 1

ANALYSIS CERTIFICATE OF 1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

TRU Chemistry Contest Chemistry 12 May 21, 2003 Time: 90 minutes

CERTIFICATE OF. Single Analyte Mass Spec Solution ± 0.1 µg/ml g/ml (measured at 20 ± 4 ºC)

AMMS-100 Atmospheric Metal Monitoring System

Chapter 3: Stoichiometry

Strategies for Determination of Elemental Impurities in Complex Samples

Solutions and Ions. Pure Substances

Rapid Detection of Americium-241 in Food by Inductively-Coupled Plasma Mass Spectrometry

CERTIFICATE OF. Single Analyte Custom Grade Solution g/ml (measured at 20 ± 4 ºC) Graviametric NIST SRM Lot Number: See Sec. 4.

Course theme. Three hours of lab Complete E1 (Parts 1, 2, 3, 4, and 5B) Prepare discussion presentation Prepare team report.

Three hours of lab Complete E1 (Parts 1, 2, 3, 4, and 5B) Prepare discussion presentation Prepare team report. Course theme

Simultaneous ICP-MS in the Pharmaceutical Industry

Ultra-fast determination of base metals in geochemical samples using the 5100 SVDV ICP-OES

Rapid Analysis of High-Matrix Environmental Samples Using the Agilent 7500cx ICP-MS. Application. Author. Abstract. Introduction.

CHEMICAL COMPOUNDS MOLECULAR COMPOUNDS

The Benefits of Gravimetric Sample Preparation

ORBITAL DIAGRAM - A graphical representation of the quantum number "map" of electrons around an atom.

OES - Optical Emission Spectrometer 2000

Single Analyte Custom Grade Solution g/ml (measured at 20 ± 1 ºC) ICP Assay NIST SRM 3163 Lot Number:

Semiquantitative Screening of Pharmaceutical Antiviral Drugs using the Agilent 7500ce ICP-MS in Helium Collision Mode

Single Analyte Custom Grade Solution. CGWH2O1 M2-W H2O µg/ml ea: Tungsten Ammonium Metatungstate

(please print) (1) (18) H IIA IIIA IVA VA VIA VIIA He (2) (13) (14) (15) (16) (17)

Periodic Table. - Mendeleev was able to predict the properties of previously unknown elements using his "periodic law" Modern periodic table

Using FIMS to Determine Mercury Content in Sewage Sludge, Sediment and Soil Samples

Metallurgical Chemistry. An Audio Course for Students

Example: Helium has an atomic number of 2. Every helium atom has two protons in its nucleus.

CHEMICAL COMPOUNDS MOLECULAR COMPOUNDS

Reporting Category 1: Matter and Energy

Experiment Three. Lab two: Parts 2B and 3. Halogens used in Parts 2 and 3. Lab one: Parts 1 and 2A. Halogens (Family VIIA) used in Parts 2 and 3

Faculty of Natural and Agricultural Sciences Chemistry Department. Semester Test 1 MEMO. Analytical Chemistry CMY 283

ICP-OES Application Note Number 35

Single Analyte Mass Spec Solution ± µg/ml g/ml (measured at 20 ± 1 ºC) METHOD NIST SRM# SRM LOT# Calculated See Sec. 4.

1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

CHEMICAL COMPOUNDS MOLECULAR COMPOUNDS

Reporting Category 1: Matter and Energy

Microsoft Excel Directions

Three hour lab. Chem : Sept Experiment 2 Session 2. Preparation Pre-lab prep and reading for E2, Parts 3-5

Periodic Table. Modern periodic table

Gases. Properties of Gases Kinetic Molecular Theory of Gases Pressure Boyle s and Charles Law The Ideal Gas Law Gas reactions Partial pressures.

CERTIFICATE OF. Single Analyte Custom Grade Solution. ICP Assay NIST SRM 3120a Lot Number: Calculated NIST SRM Lot Number: See Sec. 4.

Multi Analyte Custom Grade Solution. Calcium, Iron, Potassium,

Atomic weight: This is a decimal number, but for radioactive elements it is replaced with a number in parenthesis.

Transcription:

Elemental Scientific prepfast ICP-MS: USP <232><233> Oral Drugs by Dissolution Automated Inline Calibration and Sample Dilution Authors: Kyle Uhlmeyer and Paul Field (field@icpms.com) Brief The prepfast inline autodilution system with ICP-MS fully automates USP <233> sample dilutions and J based calibrations. The prepfast automatically 1) dilutes a single stock standard to build linear calibration curves and 2) dilutes samples to the appropriate Total Dissolved Solids (TDS) surpassing all USP <233> validation criteria. Features: Autocalibration from a single J stock standard Spike Recovery USP <233> Definition: Auto Sample Dilution Priority Sample Dilution Daily walk-up and analyze ICP-MS instrument for USP Perfect for laboratories new to ICP-MS Automate labor intensive steps to significantly reduce notebook entries Elemental Scientific Figure 1. Excellent recovery for 1J spike to Naproxen and OTC flu remedy indicates the method is very robust, constantly yielding spike recoveries (< ± 10%) that are significantly better than the USP threshold (70-150%). 1

Fill Loop V2:P7+ Load V1:P6 Load Sample S4:J Spike Waste S2:Carrier Carrier Vacuum Dilute Sample V2:P7+ Inject S3:Diluent V1:P6 Load To ICPMS Sample S4:J Spike S2:Carrier Waste Carrier Vacuum S3:Diluent To ICPMS Figure 2. The prepfast system schematic illustrating a two-step process of loading sample into a loop and injecting sample while performing inline dilution. Abstract USP <233> outlines specific protocols for the dissolution and analysis of metal impurities in solid samples. Calibration and validation protocols are based on a target (J) value that is a function of PDE (µg/day), final dilution (0.2% = 500x) and a drugs daily dose (g/day). The prepfast automatically dilutes a single stock standard to build linear calibration (r 2 > 0.999s) for any J value. A 500 fold final dilution factor equates to an appropriate Total Dissolved Solids (TDS) for ICP-MS. Solid samples (1 g) initially digested in 50 ml of acid are automatically diluted inline 10x by prepfast to obtain a final TDS of 0.2%, eliminating a second manual dilution step. The seamlessly integrated prepfast ICP-MS system easily surpasses USP <233> validation criteria of, 1) stability < ± 5% (USP limit ± 20%), 2) repeatability < ± 3% (USP limit ± 20%), 3) ruggedness < ± 4% (USP limit ± 25%) and 4) accuracy < ±10% (USP limit ± 20%). Automating the full calibration and sample dilution process removes human error and reduces notebook entries simplifying compliance with FDA s 21 CFR Part 11 record integrity regulation. 2

Introduction The oral route has the highest Permissible Daily Exposure (PDE) of all pathways. Oral drugs in the solid phase must first be digested and diluted to an appropriate Total Dissolved Solid (TDS) concentration (0.2%) for ICP-MS analysis. USP <233> outlines protocols for the dissolution of solid drugs. In this study, Over-the-Counter (OTC) flu remedy powder and Naproxen tablets are digested in an open vessel (warm 50 ml 2% HNO 3 / 0.5% HCl) mixture and closed vessel microwave system (50 ml 10% HNO 3 / 2.5% HCl / 2% H 2 O 2 ) mixture, respectively. This equates to a 500 fold dilution of the solid and would either require large volumes of diluent (e.g. 0.2 g in 100 ml - 1g in 500 ml) or a second manual 10 fold dilution step to reach 0.2% TDS. Dilution factors entered into the ICP-MS software are used by prepfast for precise and accurate inline dilutions, thereby eliminating the second manual dilution step. USP <233> outlines specific validation protocols that require standardization, precision and spike recovery to be based on a target (J) value. The prepfast ICP-MS system calibrates and dilutes samples easily fulfilling all acceptance criteria outlined by USP <233>. USP <232> <233> Definition: Table 1. Maximum Permissible Daily Exposure - PDE Element Oral Daily Dose PDE (µg/day) LVP Component Limit (µg/g) Cd 5 0.5 Pb 5 0.5 As 15 1.5 Hg 30 3 Co 50 5 V 100 10 Ni 200 20 Tl 8 0.8 Au 100 10 Pd 100 10 Ir 100 10 Os 100 10 Rh 100 10 Ru 100 10 Se 150 15 Ag 150 15 Pt 100 10 Li 550 55 Sb 1200 120 Ba 1400 140 Mo 3000 300 Cu 3000 300 Sn 6000 600 Cr 11000 1100 Table 1. The USP Chapter <232> defined PDE (µg/ day) values for Oral drugs are used (Figure 3) to calculate target values (J). USP <233> requires a calibration curve and a series of QC validation protocols including repeatability, ruggedness and spike recovery be based on the J value. *Based on an assumed density of 1.00 g/ml Figure 3. USP <232><233> defined calculation of J using Cd as an example. PDE from Table 1 is combined with a hypothetical daily dose (1 g) and a dilution factor of 500. It is clear from this calculation that J value is inversely proportional to the daily dose. 3

OTC Flu Remedy: Closed vessel digested (2% HNO 3, 0.5% HCl) USP <232> <233> Definition: Naproxen: Microwave digested (10% HNO 3, 2.5% HCl, 2% H 2 O 2 ) USP <232> <233> Definition: USP <233> Definition: Standardization solution 1: 2J of the Target Element(s) in a Matched Matrix Standardization solution 2: 0.5J of the Target Element(s) Isotope Table 2. J Values for a Range of Daily Doses PDE (µg/day) 1g/day daily dose J Values in final solution 0.2% TDS (µg/l) 5g/day daily dose 20g/day daily dose 0.5J 2J 0.5J 2J 0.5J 2J Cd 111 5 5 20 1 4 0.25 1 Pb 208 5 5 20 1 4 0.25 1 As 75 15 15 60 3 12 0.75 3 Hg 202 30 30 120 6 24 0.15 0.6 Ir 193 100 100 400 20 80 5 20 Os 192 100 100 400 20 80 5 20 Pd 106 100 100 400 20 80 5 20 Pt 195 100 100 400 20 80 5 20 Rh 103 100 100 400 20 80 5 20 Ru 102 100 100 400 20 80 5 20 Mo 98 3000 3000 400 600 2400 600 2400 Ni 60 200 200 800 40 160 40 160 V 51 100 100 400 20 80 20 20 Cu 63 3000 3000 12000 600 2400 600 2400 Table 2. Calculated 0.5 and 2J values for a range of daily doses using formula in Figure 3. 4

"J" Calibrations - 1g Daily Dose 0.999997 2 J 0.5 J "J" Calibrations - 20g Daily Dose 0.999958 2 J 0.5 J Figure 4. Fully automated inline dilutions of a single stock standard are used to generate linear calibration curves. The formula from figure 3 is used to calculate J values for drugs with a wide range of daily doses (1 and 20 g/day are given as examples). 5

"J" Calibration Coefficients 1.000 0.999 Calibration Coefficient 0.998 0.997 0.996 0.995 1g/day 5g/day 10g/day 20g/day V Ni Cu As Mo Ru Rh Pd Cd Os Ir Pt Hg Pb Figure 5. Fully automated inline dilutions from a single stock standard generates linear (>0.9999) calibration curves over a wide range of J values for all USP elements. USP <233> Definition: Repeatability prepfast - ICP-MS RSD < 3% Figure 6. Repeatability for all analytes of interest of < ± 3% at 1J spike in over the counter flu remedy liquid is significantly below the USP accepted criteria of < ± 20% RSD. 6

Ruggedness USP <233> Definition: prepfast - ICP-MS RSD < 4% Figure 7. The ruggedness of the method demonstrated on 3 separate days yields accuracy (recoveries) of < ± 10% and reproducibility of < ± 4%. The USP acceptance criteria is defined as < ± 25% RSD for each target analyte. Isotope PDE (µg/day) Table 3. Results 7 Naproxen µg/day OTC Flu Remedy (Powder) µg/day V 51 100 0.102 1.08 Ni 60 200 0.141 - Cu 63 3000 0.011 - As 75 15-0.12 Mo 98 3000 - - Ru 102 100 0.006 0.04 Rh 103 100 - - Pd 106 100 - - Cd 111 5 - - Os 192 100 - - Ir 193 100 0.031 - Pt 195 100 - - Hg 202 30 - - Pb 208 5 0.016 0.06 Table 3. Results for OTC flu remedy and naproxen are significantly lower than USP PDEs.

Benefits prepfast autocalibration - Single multi-element standard for all J values prepfast auto inline dilution - Eliminate final manual dilution step Brings samples to constant total dissolved (0.2%) Easy-to-use automated system for USP protocols Pre-developed fully automated methods Exceeds all USP validation criteria: Stability, Repeatability, Ruggedness, and Accuracy Well-suited to the demands of a high throughput pharmaceutical laboratory SC-2 DX prepfast System 7277 World Communications Drive Omaha, NE 68122 USA Phone: 1.402.991.7800 Fax: 1.402.991.7799 Email: prepfast@icpms.com Web: www.prepfast.com www.icpms.com Elemental Scientific 14056