ICP Test Report Certification Packet

Similar documents
ICP Test Report Certification Packet

ICP Test Report Certification Packet

Test Report No: (1) R1 Date: 29-Apr-13 Page 1 of 5

ICP Test Report Certification Packet

Test Report No: (1) R1 Date: 29-Oct-10 Page 1 of 5

ICP Test Report Certification Packet

ICP Test Report Certification Packet

ICP Test Report Certification Packet

ICP Test Report Certification Packet

ICP Test Report Certification Packet

Test Report No: (2) Date: 24-Jun-2014 Page 1 of 5

ICP Test Report Certification Packet

ICP Test Report Certification Packet

Test Report. As per applicant s request

TEST REPORT NUMBER: SHAH TESTS CONDUCTED. (A) TEST RESULT SUMMARY FOR RoHS DIRECTIVE:

ICP Test Report Certification Packet

ICP Test Report Certification Packet

MATERIAL DECLARATION & RoHS REPORT

ICP Test Report Certification Packet

TEST REPORT NUMBER: SHAH DATE: AUG 18, 2008 APPLICANT: LITEON SEMICONDUCTOR CORP. 28-1, WU SHIN STREET, TA WU LUNG, KEELUNG 204, TAIWAN, R.O.

TEST REPORT NUMBER: SHAH S1 APPLICANT: LITEON SEMICONDUCTOR CORP. 28-1, WU SHIN STREET, TA WU LUNG, KEELUNG 204, TAIWAN, R.O.

Test Report. Applicant : RECOM Engineering GmbH & Co. KG. Date : Jun 03, 2016

ICP Test Report Certification Packet


Page 2 of 8 Test Result(s) PART NAME No.1 SILVER COLORED PASTE Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalent Chromium Cr(VI) Sum of PBBs

Test Report Number: SHAH Applicant: TE CONNECTIVITY Date: 22 Feb, 2017 BUILDING A5,NO.1528 GUMEI ROAD, SHANGHAI,CHINA Attn: CC WU

TEST REPORT NUMBER: SHAH S1 APPLICANT: LITEON SEMICONDUCTOR CORP. 28-1, WU SHIN STREET, TA WU LUNG, KEELUNG 204, TAIWAN, R.O.

TEST REPORT Reference No. : TRHZ Date : Sep. 18, 2013 Page No. : 1 of 5

ICP Test Report Certification Packet

Test Report No. SH /CHEM Date: Oct. 22, 2009 Page 1 of 5

Test Report No. : KA/2012/40043 Date : 2012/04/10 Page : 2 of 8 Test Result(s) PART NAME NO.1 : BLACK EPOXY MOLDING COMPOUNDS Test Item (s): MDL Resul

No. KE/2016/52417 Date 2016/05/26 Page 2 of 6 Test Result(s) PART NAME No.1 Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexavalent Chromium Cr(VI

Test Report No. : CE/2009/45866B Date : 2009/05/20 Page : 1 of 7

ICP Test Report Certification Packet

No. : CE/2012/A3090 Date : 2012/10/23 GAP PAD 1000SF RICK STEWART REPORT PER REQUEST FOR QUOTE, DATED 10/5/11

Test Report No. : KE/2016/B2076 Date : 2016/11/24 Page : 2 of 8 Test Result(s) PART NAME NO.1 : GRAY Test Item (s): Unit Method Cadmium (Cd) mg/kg Wit

ICP Test Report Certification Packet

No. CE/2014/51910 Date 2014/05/20 Page 2 of 5 Test Result(s) PART NAME No.1 Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalent Chromium Cr(VI

Test Report No. KD/2013/50027A-01 Date 2013/07/01 Page 2 of 6 Test Result(s) PART NAME No.1 PART NAME No.2 PART NAME No.3 Cadmium (Cd) Lead (Pb) Mercu

No. CE/2012/C1503 Date 2012/12/18 Page 2 of 6 Test Result(s) PART NAME No.1 Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexavalent Chromium Cr(VI

The following sample(s) was/were submitted and identified by/on behalf of the client as : (2) (3) (4) (5) Please refer to next page(s).

Chemical Laboratory - Kao., SGS Taiwan Ltd. Test Report No. : KE/2017/40842 Date : 2017/04/17 ROGERS CORPORATION 245 WOODSTOCK ROAD, WOODSTOCK, CT. 06

TEST REPORT. Page : 1 of 9 Report No. RT14R-U E Date: Oct. 13, : The following submitted sample(s) said to be:-

Test Report No. : KA/2012/61391 Date : 2012/06/28 Page : 2 of 9 Test Result(s) PART NAME NO.1 : BLACK EPOXY MOLDING COMPOUND Test Item (s): Unit Metho

Test Report No. : KA/2010/C2116 Date : 2011/01/05 Page : 2 of 6 Test results by chemical method (Unit: mg/kg) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexa

ICP Test Report Certification Packet

Test Report No. : KA/2012/41514 Date : 2012/05/07 Page : 2 of 9 Test Result(s) PART NAME NO.1 : SILVER NIPPON COPPER WIRE Cadmium (Cd) mg/kg With refe

Management number No. KA/2015/80033 Date 2015/08/10 Page 1 of 6 The following sample(s) was/were submitted and identified by/on behalf

Page 2 of 9 Test Result(s) PART NAME No.1 DARK BROWN PASTE Test Item(s) Cadmium (Cd) Lead (Pb) Unit Method With reference to IEC (2013) and pe

Test Report No. : CE/2008/38467 Date : 2008/04/07 Page : 2 of 11 Test Result(s) PART NAME NO.1 : BLACK PLASTIC TUBE Cadmium (Cd) Lead (Pb) Mercury (Hg

TEST REPORT. : The following submitted sample(s) said to be:-

Test Report No. : CE/2015/15894 Date : 2015/02/04 NIHON ALMIT CO., LTD. ALMIT BLDG., , YAYOICHO, NAKANO-KU, TOKYO, JAPAN Page : 1 of 7 *CE/2015/

TEST REPORT : SR A-DC, SR A-DA, SR A-DT, SR A-DN, SR C-DC, SR C-DA, SR C-DT, SR C-DN

TEST REPORT Report No. : GR:HL: DATE : 20/11/2014

Thin Film on Silicon Resistor Networks Models 2NBS, 2QSP Mold Material Change

Page 2 of 12 Test Result(s) PART NAME No.1 IC TRANSCEIVER Test Item(s) Cadmium (Cd) Unit Method With reference to IEC (2013) and performed by

TEST REPORT Report No. : GR:HL: DATE : 27/10/2014

Page 2 of 11 Test Result(s) PART NAME No.1 TRANSPARENT-YELLOW PASTE Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalent Chromium Cr(VI) Sum of

Test Report No. CE/2016/43515 Date 2016/04/22 Page 2 of 7 Test Result(s) PART NAME No.1 AMBER FILM Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) He

Test Report No. : CE/2014/B4428 Date : 2014/12/03 Page : 1 of 12 PELNOX CO., LTD. 8-7 BODAI, HADANO CITY, KANAGAWA , JAPAN *CE/2014/B4428* The

No. CE/2012/44922 Date 2012/05/03 Page 2 of 9 Test Result(s) PART NAME No.1 DARK BROWN LUMP Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalen

Chemical Laboratory - Kao., Test Report No. : KE/2018/11379 Date : 2018/01/25 Page : 2 of 8 Test Result(s) PART NAME NO.1 : CLEAR FAL FILM WITH ADHESI

Test Report No. KE/2017/C1499 Date 2018/01/02 Page 2 of 7 Test Result(s) PART NAME No.1 WHITE POLYOXYMETHYLENE Test Item(s) Cadmium (Cd) Lead (Pb) Mer

Page 2 of 10 Test Result(s) PART NAME No.1 TRANSPARENT-YELLOW PASTE Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalent Chromium Cr(VI) Sum of

Page 2 of 12 Test Result(s) PART NAME No.1 YELLOW LUMP Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexavalent Chromium Cr(VI) Sum of PBBs Monobro

Page 2 of 12 Test Result(s) PART NAME No.1 DK. BROWN LUMP Cadmium (Cd) Lead (Pb) Mercury (Hg) Antimony (Sb) Beryllium (Be) Test Item(s) Hexavalent Chr

Test Report. Report No. RLSHD Page 1 of 6

Test Report No. CE/2015/C2965A Date 2016/02/16 Page 2 of 7 Test Result(s) PART NAME No.1 MIXED ALL PARTS Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item

Page 2 of 9 Test Result(s) PART NAME No.1 SILVER COLORED PASTE Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalent Chromium Cr(VI) Sum of PBBs

Test Report No. : KA/2012/21431 Date : 2012/02/24 Page : 2 of 12 Test Result(s) PART NAME NO.1 : SILVER GRAY DIE ATTACH PASTE Test Item (s): Unit Meth

TEST REPORT. : The following submitted sample(s) said to be:- SAMPLE RECEIVED : Jan. 07, 2019 TESTING DATE : Jan. 07, 2019 ~ Jan.

TEST REPORT. * Note 2 : This report shall not be reproduced except in full without the written approval of the testing laboratory.

Test Report No. CE/2014/43454A Date 2014/04/23 Page 2 of 11 Test Result(s) PART NAME No.1 MIXED ALL PARTS Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Ite

Test Report. Report No. SCL03H Page 1 of 7

Test Report No. : CE/2009/34977 Date : 2009/03/25 Page : 1 of 10

ICP Test Report Certification Packet

TEST REPORT. ADDRESS : 77, Seokam-ro 13-gil, Iksan, Jeonllabuk-do, Korea PAGE: 1 of 8 REPORT NO. RT17R-U2181-E DATE: Dec. 29, 2017

Test Report No. CANEC Date: 01 Sep 2011 Page 1 of 8

CHI NHANH CONG TY TNHH SAN XUAT THUONG MAI HA PHONG -XUONG SAN XUAT

Test Report No. : CE/2014/50660 Date : 2014/05/22 Page : 2 of 14 Test Result(s) PART NAME No.1 Cadmium (Cd) Lead (Pb) Mercury (Hg) Antimony (Sb) Test

Page 2 of 12 Test Result(s) PART NAME No.1 INTEGRATED CIRCUITS Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexavalent Chromium Cr(VI) Sum of PBBs

Applicant: Cactus Technologies Ltd Date : Apr 07, 2010 Suite C 15/F Capital Trade Center 62 Tsun Yip Street Kwun Tong Kowloon Hong Kong

Test Report No. : KA/2014/61579 Date : 2014/07/07 Page : 2 of 14 Test Result(s) PART NAME NO.1 : GOLD BONDING WIRE Test Item (s): Unit Method Cadmium

Test Report No. : CE/2014/32788 Date : 2014/03/27 Page : 2 of 14 Test Result(s) PART NAME No.1 : YELLOW SHEET Cadmium (Cd) Lead (Pb) Mercury (Hg) Test

Page 2 of 12 Test Result(s) PART NAME No.1 INTEGRATED CIRCUITS Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexavalent Chromium Cr(VI) Sum of PBBs

ICP Test Report Certification Packet

Page 2 of 12 Test Result(s) PART NAME No.1 INTEGRATED CIRCUITS Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalent Chromium Cr(VI) ( ) Sum of

Page 2 of 12 Test Result(s) PART NAME No.1 INTEGRATED CIRCUITS Test Item(s) Cadmium (Cd) Unit Method With reference to IEC (2013) and performe

Test Report No. : CE/2013/51536 Date : 2013/05/29 Page : 2 of 14 Test Result(s) PART NAME No.1 : YELLOW SHEET Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexa

Chemical Laboratory - Kao., SGS Taiwan Ltd. Test Report No. : KA/2017/50850 Date : 2017/05/25 HERAEUS MATERIALS SINGAPORE PTE LTD BLOCK 5002, ANG MO K

Page 2 of 12 Test Result(s) PART NAME No.1 INTEGRATED CIRCUITS Test Item(s) Cadmium (Cd) Unit Method With reference to IEC (2013) and performe

TEST REPORT. : Lead Frame / Ag is plated on Ni-Fe Alloy-A42 material

Page 2 of 12 Test Result(s) PART NAME No.1 INTEGRATED CIRCUITS Cadmium (Cd) Lead (Pb) Test Item(s) Unit Method With reference to IEC (2013) an

Test Report. Report No. RLSHE Page 2 of 5 Test Result: Content 1 2

Test Report No. CE/2017/62572 Date 2017/06/19 Page 2 of 7 Test Result(s) PART NAME No.1 PINK SHEET Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) He

Page 2 of 10 Test Result(s) PART NAME No.1 LT.GRAY SHEET Test Item(s) Cadmium (Cd) Lead (Pb) Unit Method With reference to IEC (2013) and perf

Chemical Laboratory - Kao., Page 2 of 14 Test Result(s) PART NAME No.1 SILVER COLORED PASTE Cadmium (Cd) Test Item(s) Unit Method mg/kg With reference

TEST REPORT. Address : , Doksan-dong, Geumcheon-gu, Seoul, Korea Page: 1 of 12 Report No. RT16R-S E Date: Jul.

Transcription:

ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: Pico Product #: 473xxxL Series Issue Date: February 16, 2011 It is hereby certified by Littelfuse, Inc. that there is neither RoHS (EU Directive 2002/95/EC)-restricted substance nor such use, for materials to be used for unit parts, for packing/packaging materials, and for additives and the like in the manufacturing processes. In addition, it is hereby reported to you that the parts and sub-materials, the materials to be used for unit parts, the packing/packaging materials, and the additives and the like in the manufacturing processes, are all composed of the following components. Issued by: <Global EHS Engineer> (1) Parts, sub-materials and unit parts This document covers the Pico RoHS-Compliant series products manufactured by Littelfuse, Inc. < Raw Materials Used Please see Table 1 (2) The ICP data on all measurable substances Please see appropriate pages as identifed in Table 1 Remarks: Pb (lead) contained in the high temperature melting solder > 85% and is categorized as exempt under section 7a of the RoHS Annex. 1

Table 1: List of Raw Materials covered by this report Total Parts Raw Material Part Number Raw Material Description Page(s) 1 909-371 Body 3-8 2 082xxx-001 99% Cu Sn Plated Wire 9-13 3 692320 Solder 14-19 4 910-271 Caps 20-24 5 648102 Yarn 25-31 6 648106-001 Yarn 32-37 7 648112-001 Yarn 38-43 8 087234 Pico Gold Powder 44-49 2 Form 585-047 Rev. A 2/21/06

Test Report Number : TWNC00176941 Applicant: Littelfuse, Philippines Inc. Date : Oct 08, 2010 LIMA Technology Center, Lipa City, Malvar, Batangas Sample Description: One (1) group of submitted samples said to be : Part Description : Body Part Number : 909-371 Date Sample Received : Oct 04, 2010 Date Test Started : Oct 05, 2010 Test Conducted : As requested by the applicant, for details please refer to attached pages. Authorized By: On Behalf Of Intertek Testing Services Taiwan Limited K. Y. Liang Director This report shall not be reproduced except in full, without the written approval of the laboratory. Page 1 Of 6

Number : TWNC00176941 Test Conducted (Ⅰ) Test Result Summary : Testing Item Result (ppm) Gray Material Heavy Metal Cadmium (Cd) content Lead (Pb) content 94 Mercury (Hg) content Chromium VI (Cr 6+ ) content Polybrominated Biphenyls (PBBs) Monobrominated Biphenyls (MonoBB) Dibrominated Biphenyls (DiBB) Tribrominated Biphenyls (TriBB) Tetrabrominated Biphenyls (TetraBB) Pentabrominated Biphenyls (PentaBB) Hexabrominated Biphenyls (HexaBB) Heptabrominated Biphenyls (HeptaBB) Octabrominated Biphenyls (OctaBB) Nonabrominated Biphenyls (NonaBB) Decabrominated Biphenyl (DecaBB) Polybrominated Diphenyl Ethers (PBDEs) Monobrominated Diphenyl Ethers (MonoBDE) Dibrominated Diphenyl Ethers (DiBDE) Tribrominated Diphenyl Ethers (TriBDE) Tetrabrominated Diphenyl Ethers (TetraBDE) Pentabrominated Diphenyl Ethers (PentaBDE) Hexabrominated Diphenyl Ethers (HexaBDE) Heptabrominated Diphenyl Ethers (HeptaBDE) Octabrominated Diphenyl Ethers (OctaBDE) Nonabrominated Diphenyl Ethers (NonaBDE) Decabrominated Diphenyl Ether (DecaBDE) Halogen Content Fluorine (F) Chlorine (Cl) Bromine (Br) Iodine (I) Remarks: ppm = Parts per million based on weight of tested sample = mg/kg = Not detected Responsibility Of Chemist : Irene Chiou / Kevin Liu / Cathy Chen Date Sample Received : Oct 04, 2010 Testing Period : Oct 05, 2010 To Oct 07, 2010 Page 2 Of 6

Number : TWNC00176941 Test Conducted (Ⅱ) RoHS Requirement: Restricted Substances Cadmium (Cd) Content Lead (Pb) Content Mercury (Hg) Content Chromium VI (Cr 6+ ) Content Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ehters (PBDEs) Limits 0.01% (100ppm) The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for homogeneous material. (Ⅲ) Test Method: Testing Item Testing Method Reporting Limit Cadmium (Cd) 1.0:2008 in clause 8/9/10, by content microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. 2 ppm Lead (Pb) content 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and 2 ppm Mercury (Hg) content Chromium VI (Cr 6+ ) content Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ethers (PBDEs) Halogen Content determined by ICP-OES. 1.0:2008 in clause 7, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. 1.0:2008 in annex C, by alkaline digestion and determined by UV-Vis spectrophotometer. 1.0:2008 in annex A, by solvent extraction and determined by GC-MSD and further HPLC confirmation when necessary. 1.0:2008 in annex A, by solvent extraction and determined by GC-MSD and further HPLC confirmation when necessary. With reference to EN 14582:2007 by calorimetric bomb with oxygen and determined by ion chromatography Remark: Reporting limit = Quantitation limit of analyte in sample 2 ppm 1 ppm 5 ppm 5 ppm 50 ppm Page 3 Of 6

Number : TWNC00176941 Test Conducted (Ⅳ) Measurement Flowchart: Test For Cd/Pb/Hg/Chromium (VI)/PBBS/PBDES Contents Reference Standard: IEC 62321 edition 1.0:2008 Sampling/grinding or cutting Cd/Pb/Hg Metal Cr 6+ Polymers / electronics PBBs/PBDEs For different material, digest the sample with appropriate acid *1 Confirm the tested samples are totally dissolved By spot test Get 50cm 2 sample Negative *2 Weigh sample and add alkaline solution Definite temp. extraction Weigh sample and add organic solvent By Soxhlet extraction or Solvent extraction Make up with deionized water By boiling water extraction Cool and filter the extract Concentrate the extract and make up with organic solvent Analyzed by ICP-OES Analyzed by GC-MSD Make up with deionized water and add diphenylcarbazide solution Remarks: Analyzed by UV-VIS *1: List Of Appropriate Acid: Material Acid Added For Digestion Polymers HNO 3, HCl,HF,H 2 O 2, H 3 BO 3 Metals HNO 3, HCl,HF Electronics HNO 3, HCl,H 2 O 2, HBF 4 *2: If the result of spot test is positive, Chromium VI would be determined as detected. Page 4 Of 6

Number : TWNC00176941 Test Conducted (Ⅳ) Measurement Flowchart: Test For Halogen Content Reference Standard: EN 14582 Sampling/grinding or cutting Add absorbent in a calorimetric bomb & place weighed sample in equipment Fill the calorimetric bomb with oxygen Ignite then leave the flask at room temperature Transfer the absorbent into a volumetric flask Make up with deionized water Analyzed by ion chromatography End Of Report Page 5 Of 6

Number : TWNC00176941 Test Conducted Photo Page 6 Of 6

Test Report Number : TWNC00181312 Applicant: Littelfuse, Philippines Inc. Date : Nov 11, 2010 LIMA Technology Center, Lipa City, Malvar, Batangas Sample Description: One (1) group of submitted samples said to be : Part Description : Element Part Number : 082XXX-001 Date Sample Received : Nov 05, 2010 Date Test Started : Nov 08, 2010 Test Conducted : As requested by the applicant, for details please refer to attached pages. Authorized By: On Behalf Of Intertek Testing Services Taiwan Limited K. Y. Liang Director This report shall not be reproduced except in full, without the written approval of the laboratory. Page 1 Of 5

Number : TWNC00181312 Test Conducted (Ⅰ) Test Result Summary : Result (ppm) Testing Item Silvery Metal Thread Heavy Metal Cadmium (Cd) content Lead (Pb) content 48 Mercury (Hg) content Chromium VI (Cr 6+ ) content (mg/kg with 50cm 2 ) Negative (< 0.02) Remarks: ppm = Parts per million based on weight of tested sample = mg/kg = Not detected < = Less than mg/kg with 50cm 2 = milligram per kilogram with 50 square centimetre Responsibility Of Chemist : Irene Chiou / Kevin Liu / Cathy Chen Date Sample Received : Nov 05, 2010 Testing Period : Nov 08, 2010 to Nov 11, 2010 (Ⅱ) RoHS Requirement: Restricted Substances Cadmium (Cd) Content Lead (Pb) Content Mercury (Hg) Content Chromium VI (Cr 6+ ) Content Limits 0.01% (100ppm) The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for homogeneous material. Page 2 Of 5

Number : TWNC00181312 Test Conducted (Ⅲ) Test Method: Testing Item Testing Method Reporting Limit 1.0:2008 in clause 8/9/10, by Cadmium (Cd) microwave digestion until the tested content samples are totally dissolved and 2 ppm determined by ICP-OES. Lead (Pb) content 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and 2 ppm Mercury (Hg) content Chromium VI (Cr 6+ ) content determined by ICP-OES. 1.0:2008 in clause 7, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. 1.0:2008 in annex B, by boiling water extraction and determined by UV-Vis spectrophotometer. Remark: Reporting limit = Quantitation limit of analyte in sample 2 ppm 0.02 mg/kg with 50cm 2 Page 3 Of 5

Number : TWNC00181312 Test Conducted (Ⅳ) Measurement Flowchart: Test For Cd/Pb/Hg/Chromium (VI) Reference Standard:IEC 62321 edition 1.0:2008 Sampling/grinding or cutting Cd/Pb/Hg Metal Cr 6+ Polymers / Electronics For different material, digest the sample with appropriate acid *1 Confirm the tested samples are totally dissolved By spot test Negative *2 Get 50cm 2 sample Weigh sample and add alkaline solution Definite temp. extraction Make up with deionized water Boiling water extraction Cool and filter the extract Analyzed by ICP-OES Make up with deionized water and add diphenylcarbazide solution Remarks: *1: List Of Appropriate Acid: Material Analyzed by UV-VIS Acid Added For Digestion Polymers HNO 3, HCl,HF,H 2 O 2, H 3 BO 3 Metals HNO 3, HCl,HF Electronics HNO 3, HCl,H 2 O 2, HBF 4 *2: If the result of spot test is positive, Chromium VI would be determined as detected. End Of Report Page 4 Of 5

Number : TWNC00181312 Test Conducted Photo Page 5 Of 5

Test Report No: 10222124(1) Date: 19-Jan-11 Page 1 of 6 Kester Components Pte Ltd 500 Chai Chee Lane, Singapore 469024 The following sample(s) was/were submitted and identified by/on behalf of the client as: Sample Description : RK-3-K71 (P/N: 692320 / Lot: 1004401007) Sample Receiving Date : 12-Jan-11 Testing Period : 13-Jan-11 to 18-Jan-11 Test Requested : In accordance with the RoHS Directive 2002/95/EC, and its amendment directives. Test Result(s) : Please refer to next page(s). Conclusion : Based on the performed tests on submitted sample(s), the results comply with the RoHS Directive 2002/95/EC and its subsequent amendments. Signed for and on behalf of SGS Testing & Control Services Singapore Pte Ltd Y.C. Tham Laboratory Manager Test Location: 26 Ayer Rajah Crescent, #07-08, Singapore 139944 This document is issued by the Company under its General Conditions of Service accessible at www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company s findings at the time of its intervention only and within the limits of Client s instructions, if any. The Company s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 30 days only. This document cannot be reproduced except in full, without prior approval of the Company. SGS Testing & Control Services Singapore Pte Ltd 26 Ayer Rajah Crescent #03-07 Singapore 139944 t +65 6379 0111 f+65 6777 2914 www.sgs.com Member of SGS Group

Test Report No: 10222124(1) Date: 19-Jan-11 Page 2 of 6 Test Result(s): Sample Description : RK-3-K71 (P/N: 692320 / Lot: 1004401007) Test Item(s): Unit Method Results MDL RoHS Limit Cadmium(Cd) Lead (Pb) Mercury (Hg) Hexavalent Chromium (CrVI) (By spot test / boiling water extraction) Sum of PBBs Monobromobiphenyl Dibromobiphenyl Tribromobiphenyl Tetrabromobiphenyl Hexabromobiphenyl Pentabromobiphenyl Heptabromobiphenyl Octabromobiphenyl Nonabromobiphenyl Decabromobiphenyl Sum of PBDEs Monobromodiphenyl ether Dibromodiphenyl ether Tribromodiphenyl ether Tetrabromodiphenyl ether Pentabromodiphenyl ether Hexabromodiphenyl ether Heptabromodiphenyl ether Octabromodiphenyl ether Nonabromodiphenyl ether Decabromodiphenyl ether ## mg/kg With reference to IEC62321, n.d. 2 100 Ed1:2008. Analysis was performed by ICP/AES mg/kg With reference to IEC62321, 901893.9 + 2 1000 Ed1:2008. Analysis was performed by ICP/AES mg/kg With reference to IEC62321, n.d. 2 1000 Ed1:2008. Analysis was performed by ICP/AES --- With reference to IEC62321, Negative 0.02 mg/kg # Ed1:2008 and performed by Spot with 50 cm 2 test / boiling water extraction surface area method. (see Note 9) mg/kg n.d. - 1000 mg/kg n.d. 5 - mg/kg n.d. 5 - mg/kg n.d. 5 - mg/kg n.d. 5 - mg/kg n.d. 5 - mg/kg n.d. 5 - mg/kg n.d. 5 - mg/kg n.d. 5 - mg/kg n.d. 5 - With reference to IEC62321, mg/kg n.d. 5 - Ed1:2008. Analysis was mg/kg n.d. - 1000 performed by GC/MS mg/kg n.d. 5 - mg/kg n.d. 5 - mg/kg n.d. 5 - mg/kg n.d. 5 - mg/kg n.d. 5 - mg/kg n.d. 5 - mg/kg n.d. 5 - mg/kg n.d. 5 - mg/kg n.d. 5 - mg/kg n.d. 5 - Test Location: 26 Ayer Rajah Crescent, #07-08, Singapore 139944 This document is issued by the Company under its General Conditions of Service accessible at www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company s findings at the time of its intervention only and within the limits of Client s instructions, if any. The Company s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 30 days only. This document cannot be reproduced except in full, without prior approval of the Company. SGS Testing & Control Services Singapore Pte Ltd 26 Ayer Rajah Crescent #03-07 Singapore 139944 t +65 6379 0111 f+65 6777 2914 www.sgs.com Member of SGS Group

Test Report No: 10222124(1) Date: 19-Jan-11 Page 3 of 6 Note: (1) mg/kg = ppm ; 0.1wt% = 1000ppm (2) n.d.= Not Detected (3) MDL = Method Detection Limit (4) ## = The exemption of DecaBDE in polymeric application according 2005/717/EC was overruled by the European Court of Justice by its decision of 01.04.2008. Subsequently DecaBDE will be included in the sum of PBDE after 01.07.2008. (5) - = Not regulated (6) --- : No unit (Qualitative Test) (7) * : Exceeds limit (8) # : Positive means the presence of CrVI on the tested areas. Negative means the absence of CrVI on the tested areas. (9) Spot-test: Negative = Absence of Cr(VI) coating / surface layer Positive = Presence of Cr(VI) coating / surface layer The tested sample should be further verified by boiling-water-extraction method if the spot test result cannot be confirmed. Boiling-water extraction: Negative = Absence of Cr(VI) coating / surface layer Positive = Presence of Cr(VI) coating / surface layer the detected concentration in boiling-water-extraction solution is equal or greater than 0.02 mg/kg with 50 cm 2 sample surface area. + Exemption: The received sample is exempted under directive 2002/95/EC Annex Article 7: lead in high melting temperature solder type solders (i.e. tin-lead solder alloys containing more than 85% of lead). Lab Analyst(s): Jay, Jojo and Eileen Remarks: Sample received was totally dissolved by preconditioning method. Sample photo: Sample Description : RK-3-K71 (P/N: 692320 / Lot: 1004401007) SGS authenticate the photo on original report only Test Location: 26 Ayer Rajah Crescent, #07-08, Singapore 139944 This document is issued by the Company under its General Conditions of Service accessible at www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company s findings at the time of its intervention only and within the limits of Client s instructions, if any. The Company s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 30 days only. This document cannot be reproduced except in full, without prior approval of the Company. SGS Testing & Control Services Singapore Pte Ltd 26 Ayer Rajah Crescent #03-07 Singapore 139944 t +65 6379 0111 f+65 6777 2914 www.sgs.com Member of SGS Group

Test Report No: 10222124(1) Date: 19-Jan-11 Page 4 of 6 Process Flow of IEC 62321 (Pb, Cd, Hg & Cr 6+ ) Cutting / Preparation Sample Measurement Pb,Cd Acid digestion by suitable acid depended on different sample material Filtration Hg Microwave digestion with HNO3/HCl/HF Cr (Vl) Add appropriate amount of digestion reagent Heat to appropriate temperature to extract Solution Residue Cool, filter digestate through filter ICP-AES 1)Alkali Fusion 2)HCl to dissolve Add diphenyl-carbazide for color development Measure the absorbance at 540 nm by UV-VIS Remarks: Sample received was totally dissolved by preconditioning method. (CrVl method excluded) Test Location: 26 Ayer Rajah Crescent, #07-08, Singapore 139944 This document is issued by the Company under its General Conditions of Service accessible at www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company s findings at the time of its intervention only and within the limits of Client s instructions, if any. The Company s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 30 days only. This document cannot be reproduced except in full, without prior approval of the Company. SGS Testing & Control Services Singapore Pte Ltd 26 Ayer Rajah Crescent #03-07 Singapore 139944 t +65 6379 0111 f+65 6777 2914 www.sgs.com Member of SGS Group

Test Report No: 10222124(1) Date: 19-Jan-11 Page 5 of 6 Process Flow of Cr(Vl) by Boiling Water Extraction (IEC62321) Add appropriate amount of DI water Heat to appropriate temperature to extract Cool, filter digestate through filter Add diphenyl-carbazide for color development A red color indicates the presence of CrVl Test Location: 26 Ayer Rajah Crescent, #07-08, Singapore 139944 This document is issued by the Company under its General Conditions of Service accessible at www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company s findings at the time of its intervention only and within the limits of Client s instructions, if any. The Company s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 30 days only. This document cannot be reproduced except in full, without prior approval of the Company. SGS Testing & Control Services Singapore Pte Ltd 26 Ayer Rajah Crescent #03-07 Singapore 139944 t +65 6379 0111 f+65 6777 2914 www.sgs.com Member of SGS Group

Test Report No: 10222124(1) Date: 19-Jan-11 Page 6 of 6 Process Flow of PBBs and PBDEs by GC/MS (IEC 62321) First Testing Process Optional screen process Confirmation process... Cutting/Preparation Sample Pre-treatment Screening Analysis Solvent Extraction Concentrate/Dilute extracted solution Filter High Mass Range GC/MS Data ***End of Report*** Test Location: 26 Ayer Rajah Crescent, #07-08, Singapore 139944 This document is issued by the Company under its General Conditions of Service accessible at www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company s findings at the time of its intervention only and within the limits of Client s instructions, if any. The Company s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 30 days only. This document cannot be reproduced except in full, without prior approval of the Company. SGS Testing & Control Services Singapore Pte Ltd 26 Ayer Rajah Crescent #03-07 Singapore 139944 t +65 6379 0111 f+65 6777 2914 www.sgs.com Member of SGS Group

Test Report Number : TWNC00182566 Applicant: Littelfuse, Philippines Inc. Date : Nov 22, 2010 LIMA Technology Center, Lipa City, Malvar, Batangas Sample Description: One (1) group of submitted samples said to be : Part Description : Caps/ Lead Assay (metal) Part Number : 910-271 Date Sample Received : Nov 17, 2010 Date Test Started : NOV 17, 2010 Test Conducted : As requested by the applicant, for details please refer to attached pages. Authorized By: On Behalf Of Intertek Testing Services Taiwan Limited K. Y. Liang Director This report shall not be reproduced except in full, without the written approval of the laboratory. Page 1 Of 5

Number : TWNC00182566 Test Conducted Testing Item Result (ppm) (1) (2) Heavy Metal Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr 6+ ) content (mg/kg with 50cm 2 Negative Negative ) (< 0.02)(#) (< 0.02)(#) Remarks: ppm = Parts per million based on weight of tested sample = mg/kg = Not detected < = Less than mg/kg with 50cm 2 = milligram per kilogram with 50 square centimetre Negative = A negative test result indicated positive observation was not found at the time of testing. # = Due to the insufficient sample area, reduced total sample surface of 10 cm 2 was used and the dilution factor was adjusted accordingly. Tested Components (1) Coppery Substrate (2) Silvery Plating Responsibility Of Chemist : Irene Chiou / Kevin Liu / Cathy Chen Date Sample Received : Nov 17, 2010 Testing Period : Nov 17, 2010 To Nov 22, 2010 (Ⅱ) RoHS Requirement: Restricted Substances Cadmium (Cd) Content Lead (Pb) Content Mercury (Hg) Content Chromium VI (Cr 6+ ) Content Limits 0.01% (100ppm) The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for homogeneous material. Page 2 Of 5

Number : TWNC00182566 Test Conducted (Ⅲ) Test Method: Testing Item Testing Method Reporting Limit 1.0:2008 in clause 8/9/10, by Cadmium (Cd) microwave digestion until the tested content samples are totally dissolved and 2 ppm determined by ICP-OES. 1.0:2008 in clause 8/9/10, by Lead (Pb) content microwave digestion until the tested 2 ppm samples are totally dissolved and Mercury (Hg) content Chromium VI (Cr 6+ ) content determined by ICP-OES. 1.0:2008 in clause 7, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. 1.0:2008 in annex B, by boiling water extraction and determined by UV-Vis spectrophotometer. Remark: Reporting limit = Quantitation limit of analyte in sample 2 ppm 0.02 mg/kg with 50cm 2 Page 3 Of 5

Test Conducted (IV) Measurement Flowchart: Test For Cd/Pb/Hg/Chromium (VI) Reference Standard:IEC 62321 edition 1.0:2008 Number : TWNC00182566 Sample preparation Take sample and immerse into Aqua Regia, start to strip plating layer Stop the stripping procedure upon color change completely Take the Aqua solution as plating component and stripped body as substrate component Cd/Pb/Hg Metal Cr 6+ Polymers / electronics For different material, digest the sample with appropriate acid *1 Confirm the tested samples are totally dissolved By spot test Get 50cm 2 sample Negative *2 Weigh sample and add alkaline solution Definite temp. extraction Make up with deionized water By boiling water extraction Cool and filter the extract Analyzed by ICP-OES Make up with deionized water and add diphenyl-carbazide solution Analyzed by UV-VIS Remarks: *1: List Of Appropriate Acid: Material Acid Added For Digestion Polymers HNO 3, HCl,HF,H 2 O 2, H 3 BO 3 Metals HNO 3, HCl,HF Electronics HNO 3, HCl,H 2 O 2, HBF 4 *2: If the result of spot test is positive, Chromium VI would be determined as detected. End Of Report Page 4 Of 5

Test Conducted Number : TWNC00182566 Photo Page 5 Of 5

Test Report Number : TWNC00176948 Applicant: Littelfuse, Philippines Inc. Date : Oct 07, 2010 LIMA Technology Center, Lipa City, Malvar, Batangas Sample Description: One (1) group of submitted samples said to be : Part Description : Yarn Part Number : 648102 Date Sample Received : Oct 04, 2010 Date Test Started : Oct 05, 2010 Test Conducted : As requested by the applicant, for details please refer to attached pages. Authorized By: On Behalf Of Intertek Testing Services Taiwan Limited K. Y. Liang Director This report shall not be reproduced except in full, without the written approval of the laboratory. Page 1 Of 7

Number : TWNC00176948 Test Conducted (Ⅰ) Test Result Summary : Testing Item Heavy Metal Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr 6+ ) content Polybrominated Biphenyls (PBBs) Monobrominated Biphenyls (MonoBB) Dibrominated Biphenyls (DiBB) Tribrominated Biphenyls (TriBB) Tetrabrominated Biphenyls (TetraBB) Pentabrominated Biphenyls (PentaBB) Hexabrominated Biphenyls (HexaBB) Heptabrominated Biphenyls (HeptaBB) Octabrominated Biphenyls (OctaBB) Nonabrominated Biphenyls (NonaBB) Decabrominated Biphenyl (DecaBB) Polybrominated Diphenyl Ethers (PBDEs) Monobrominated Diphenyl Ethers (MonoBDE) Dibrominated Diphenyl Ethers (DiBDE) Tribrominated Diphenyl Ethers (TriBDE) Tetrabrominated Diphenyl Ethers (TetraBDE) Pentabrominated Diphenyl Ethers (PentaBDE) Hexabrominated Diphenyl Ethers (HexaBDE) Heptabrominated Diphenyl Ethers (HeptaBDE) Octabrominated Diphenyl Ethers (OctaBDE) Nonabrominated Diphenyl Ethers (NonaBDE) Decabrominated Diphenyl Ether (DecaBDE) Result (ppm) White Fabric Page 2 Of 7

Number : TWNC00176948 Test Conducted (Ⅰ) Test Result Summary : Testing Item Halogen Content Fluorine (F) Chlorine (Cl) Bromine (Br) Iodine (I) Result (ppm) White Fabric Remarks: ppm = Parts per million based on weight of tested sample = mg/kg = Not detected Responsibility Of Chemist : Irene Chiou / Kevin Liu / Cathy Chen Date Sample Received : Oct 04, 2010 Testing Period : Oct 05, 2010 To Oct 07, 2010 (Ⅱ) RoHS Requirement: Restricted Substances Cadmium (Cd) Content Lead (Pb) Content Mercury (Hg) Content Chromium VI (Cr 6+ ) Content Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ehters (PBDEs) Limits 0.01% (100ppm) The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for homogeneous material. Page 3 Of 7

Number : TWNC00176948 Test Conducted (Ⅲ) Test Method: Testing Item Testing Method Reporting Limit 1.0:2008 in clause 8/9/10, by Cadmium (Cd) microwave digestion until the tested content samples are totally dissolved and 2 ppm determined by ICP-OES. Lead (Pb) content 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and 2 ppm Mercury (Hg) content Chromium VI (Cr 6+ ) content Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ethers (PBDEs) Halogen Content determined by ICP-OES. 1.0:2008 in clause 7, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. 1.0:2008 in annex C, by alkaline digestion and determined by UV-Vis spectrophotometer. 1.0:2008 in annex A, by solvent extraction and determined by GC-MSD and further HPLC confirmation when necessary. 1.0:2008 in annex A, by solvent extraction and determined by GC-MSD and further HPLC confirmation when necessary. With reference to EN 14582:2007 by calorimetric bomb with oxygen and determined by ion chromatography Remark: Reporting limit = Quantitation limit of analyte in sample 2 ppm 1 ppm 5 ppm 5 ppm 50 ppm Page 4 Of 7

Number : TWNC00176948 Test Conducted (Ⅳ) Measurement Flowchart: Test For Cd/Pb/Hg/Chromium (VI)/PBBS/PBDES Contents Reference Standard: IEC 62321 edition 1.0:2008 Sampling/grinding or cutting Cd/Pb/Hg Metal Cr 6+ Polymers / electronics PBBs/PBDEs For different material, digest the sample with appropriate acid *1 Confirm the tested samples are totally dissolved By spot test Get 50cm 2 sample Negative *2 Weigh sample and add alkaline solution Definite temp. extraction Weigh sample and add organic solvent By Soxhlet extraction or Solvent extraction Make up with deionized water By boiling water extraction Cool and filter the extract Concentrate the extract and make up with organic solvent Analyzed by ICP-OES Analyzed by GC-MSD Make up with deionized water and add diphenylcarbazide solution Remarks: *1: List Of Appropriate Acid: Material Analyzed by UV-VIS Acid Added For Digestion Polymers HNO 3, HCl,HF,H 2 O 2, H 3 BO 3 Metals HNO 3, HCl,HF Electronics HNO 3, HCl,H 2 O 2, HBF 4 *2: If the result of spot test is positive, Chromium VI would be determined as detected. Page 5 Of 7

Number : TWNC00176948 Test Conducted (Ⅳ) Measurement Flowchart: Test For Halogen Content Reference Standard: EN 14582 Sampling/grinding or cutting Add absorbent in a calorimetric bomb & place weighed sample in equipment Fill the calorimetric bomb with oxygen Ignite then leave the flask at room temperature Transfer the absorbent into a volumetric flask Make up with deionized water Analyzed by ion chromatography End Of Report Page 6 Of 7

Number : TWNC00176948 Test Conducted Photo Page 7 Of 7

Test Report Number : TWNC00183561 Applicant: Littelfuse, Philippines Inc. Date : Nov 30, 2010 LIMA Technology Center, Lipa City, Malvar, Batangas Sample Description: One (1) group of submitted samples said to be : Part Description : Yarn Part Number : 648106-001 Date Sample Received : Nov 25, 2010 Date Test Started : Nov 25, 2010 Test Conducted : As requested by the applicant, for details please refer to attached pages. Authorized By: On Behalf Of Intertek Testing Services Taiwan Limited K. Y. Liang Director This report shall not be reproduced except in full, without the written approval of the laboratory. Page 1 Of 6

Test Conducted (Ⅰ) Test Result Summary : Testing Item Heavy Metal Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr 6+ ) content Polybrominated Biphenyls (PBBs) Monobrominated Biphenyls (MonoBB) Dibrominated Biphenyls (DiBB) Tribrominated Biphenyls (TriBB) Tetrabrominated Biphenyls (TetraBB) Pentabrominated Biphenyls (PentaBB) Hexabrominated Biphenyls (HexaBB) Heptabrominated Biphenyls (HeptaBB) Octabrominated Biphenyls (OctaBB) Nonabrominated Biphenyls (NonaBB) Decabrominated Biphenyl (DecaBB) Polybrominated Diphenyl Ethers (PBDEs) Monobrominated Diphenyl Ethers (MonoBDE) Dibrominated Diphenyl Ethers (DiBDE) Tribrominated Diphenyl Ethers (TriBDE) Tetrabrominated Diphenyl Ethers (TetraBDE) Pentabrominated Diphenyl Ethers (PentaBDE) Hexabrominated Diphenyl Ethers (HexaBDE) Heptabrominated Diphenyl Ethers (HeptaBDE) Octabrominated Diphenyl Ethers (OctaBDE) Nonabrominated Diphenyl Ethers (NonaBDE) Decabrominated Diphenyl Ether (DecaBDE) Halogen Content Fluorine (F) Chlorine (Cl) Bromine (Br) Iodine (I) Number : TWNC00183561 Result (ppm) White Yarn Remarks: ppm = Parts per million based on weight of tested sample = mg/kg = Not detected Responsibility Of Chemist : Irene Chiou / Kevin Liu / Cathy Chen Date Sample Received : Nov 25, 2010 Testing Period : Nov 25, 2010 To Nov 29, 2010 Page 2 Of 6

Test Conducted (Ⅱ) RoHS Requirement: Restricted Substances Cadmium (Cd) Content Lead (Pb) Content Mercury (Hg) Content Chromium VI (Cr 6+ ) Content Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ehters (PBDEs) Number : TWNC00183561 Limits 0.01% (100ppm) The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for homogeneous material. (Ⅲ) Test Method: Testing Item Testing Method Reporting Limit 1.0:2008 in clause 8/9/10, by Cadmium (Cd) content microwave digestion until the tested samples are totally dissolved and 2 ppm determined by ICP-OES. Lead (Pb) content 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and 2 ppm Mercury (Hg) content Chromium VI (Cr 6+ ) content Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ethers (PBDEs) Halogen Content determined by ICP-OES. 1.0:2008 in clause 7, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. 1.0:2008 in annex C, by alkaline digestion and determined by UV-Vis spectrophotometer. 1.0:2008 in annex A, by solvent extraction and determined by GC-MSD and further HPLC confirmation when necessary. 1.0:2008 in annex A, by solvent extraction and determined by GC-MSD and further HPLC confirmation when necessary. With reference to EN 14582:2007 by calorimetric bomb with oxygen and determined by ion chromatography Remark: Reporting limit = Quantitation limit of analyte in sample 2 ppm 1 ppm 5 ppm 5 ppm 50 ppm Page 3 Of 6

Test Conducted (Ⅳ) Measurement Flowchart: Number : TWNC00183561 Test For Cd/Pb/Hg/Chromium (VI)/PBBS/PBDES Contents Reference Standard: IEC 62321 edition 1.0:2008 For metal part Sample preparation For non-metal part Take sample and immerse into Aqua Regia, start to strip plating layer Stop the stripping procedure upon color change completely Take the Aqua solution as plating component and stripped body as substrate component Cd/Pb/Hg Metal Cr 6+ Polymers / electronics PBBs/PBDEs For different material, digest the sample with appropriate acid *1 Confirm the tested samples are totally dissolved By spot test Get 50cm 2 sample Negative *2 Weigh sample and add alkaline solution Definite temp. extraction Weigh sample and add organic solvent By Soxhlet extraction or Solvent extraction Make up with deionized water By boiling water extraction Cool and filter the extract Concentrate the extract and make up with organic solvent Analyzed by ICP-OES Analyzed by GC-MSD Make up with deionized water and add diphenylcarbazide solution Analyzed by UV-VIS Remarks: *1: List Of Appropriate Acid: Material Acid Added For Digestion Polymers HNO 3, HCl,HF,H 2 O 2, H 3 BO 3 Metals HNO 3, HCl,HF Electronics HNO 3, HCl,H 2 O 2, HBF 4 *2: If the result of spot test is positive, Chromium VI would be determined as detected. Page 4 Of 6

Test Conducted (Ⅳ) Measurement Flowchart: Number : TWNC00183561 Test For Halogen Content Reference Standard:EN 14582 Sampling/grinding or cutting Add absorbent in a calorimetric bomb & place weighed sample in equipment Fill oxygen into calorimetric bomb Ignite then leave the flask at room temperature Transfer the absorbent into a volumetric flask Make up with deionized water Analyzed by ion chromatography End Of Report Page 5 Of 6

Test Conducted Number : TWNC00183561 Photo Page 6 Of 6

Test Report Number : TWNC00183563 Applicant: Littelfuse, Philippines Inc. Date : Nov 30, 2010 LIMA Technology Center, Lipa City, Malvar, Batangas Sample Description: One (1) group of submitted samples said to be : Part Description : Yarn Part Number : 648112-001 Date Sample Received : Nov 25, 2010 Date Test Started : Nov 25, 2010 Test Conducted : As requested by the applicant, for details please refer to attached pages. Authorized By: On Behalf Of Intertek Testing Services Taiwan Limited K. Y. Liang Director This report shall not be reproduced except in full, without the written approval of the laboratory. Page 1 Of 6

Test Conducted (Ⅰ) Test Result Summary : Testing Item Heavy Metal Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr 6+ ) content Polybrominated Biphenyls (PBBs) Monobrominated Biphenyls (MonoBB) Dibrominated Biphenyls (DiBB) Tribrominated Biphenyls (TriBB) Tetrabrominated Biphenyls (TetraBB) Pentabrominated Biphenyls (PentaBB) Hexabrominated Biphenyls (HexaBB) Heptabrominated Biphenyls (HeptaBB) Octabrominated Biphenyls (OctaBB) Nonabrominated Biphenyls (NonaBB) Decabrominated Biphenyl (DecaBB) Polybrominated Diphenyl Ethers (PBDEs) Monobrominated Diphenyl Ethers (MonoBDE) Dibrominated Diphenyl Ethers (DiBDE) Tribrominated Diphenyl Ethers (TriBDE) Tetrabrominated Diphenyl Ethers (TetraBDE) Pentabrominated Diphenyl Ethers (PentaBDE) Hexabrominated Diphenyl Ethers (HexaBDE) Heptabrominated Diphenyl Ethers (HeptaBDE) Octabrominated Diphenyl Ethers (OctaBDE) Nonabrominated Diphenyl Ethers (NonaBDE) Decabrominated Diphenyl Ether (DecaBDE) Halogen Content Fluorine (F) Chlorine (Cl) Bromine (Br) Iodine (I) Number : TWNC00183563 Result (ppm) White Yarn Remarks: ppm = Parts per million based on weight of tested sample = mg/kg = Not detected Responsibility Of Chemist : Irene Chiou / Kevin Liu / Cathy Chen Date Sample Received : Nov 25, 2010 Testing Period : Nov 25, 2010 To Nov 29, 2010 Page 2 Of 6

Test Conducted (Ⅱ) RoHS Requirement: Restricted Substances Cadmium (Cd) Content Lead (Pb) Content Mercury (Hg) Content Chromium VI (Cr 6+ ) Content Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ehters (PBDEs) Number : TWNC00183563 Limits 0.01% (100ppm) The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for homogeneous material. (Ⅲ) Test Method: Testing Item Testing Method Reporting Limit 1.0:2008 in clause 8/9/10, by Cadmium (Cd) content microwave digestion until the tested samples are totally dissolved and 2 ppm determined by ICP-OES. Lead (Pb) content 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and 2 ppm Mercury (Hg) content Chromium VI (Cr 6+ ) content Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ethers (PBDEs) Halogen Content determined by ICP-OES. 1.0:2008 in clause 7, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. 1.0:2008 in annex C, by alkaline digestion and determined by UV-Vis spectrophotometer. 1.0:2008 in annex A, by solvent extraction and determined by GC-MSD and further HPLC confirmation when necessary. 1.0:2008 in annex A, by solvent extraction and determined by GC-MSD and further HPLC confirmation when necessary. With reference to EN 14582:2007 by calorimetric bomb with oxygen and determined by ion chromatography Remark: Reporting limit = Quantitation limit of analyte in sample 2 ppm 1 ppm 5 ppm 5 ppm 50 ppm Page 3 Of 6

Test Conducted (Ⅳ) Measurement Flowchart: Number : TWNC00183563 Test For Cd/Pb/Hg/Chromium (VI)/PBBS/PBDES Contents Reference Standard: IEC 62321 edition 1.0:2008 For metal part Sample preparation For non-metal part Take sample and immerse into Aqua Regia, start to strip plating layer Stop the stripping procedure upon color change completely Take the Aqua solution as plating component and stripped body as substrate component Cd/Pb/Hg Metal Cr 6+ Polymers / electronics PBBs/PBDEs For different material, digest the sample with appropriate acid *1 Confirm the tested samples are totally dissolved By spot test Get 50cm 2 sample Negative *2 Weigh sample and add alkaline solution Definite temp. extraction Weigh sample and add organic solvent By Soxhlet extraction or Solvent extraction Make up with deionized water By boiling water extraction Cool and filter the extract Concentrate the extract and make up with organic solvent Analyzed by ICP-OES Analyzed by GC-MSD Make up with deionized water and add diphenylcarbazide solution Analyzed by UV-VIS Remarks: *1: List Of Appropriate Acid: Material Acid Added For Digestion Polymers HNO 3, HCl,HF,H 2 O 2, H 3 BO 3 Metals HNO 3, HCl,HF Electronics HNO 3, HCl,H 2 O 2, HBF 4 *2: If the result of spot test is positive, Chromium VI would be determined as detected. Page 4 Of 6

Test Conducted (Ⅳ) Measurement Flowchart: Number : TWNC00183563 Test For Halogen Content Reference Standard:EN 14582 Sampling/grinding or cutting Add absorbent in a calorimetric bomb & place weighed sample in equipment Fill oxygen into calorimetric bomb Ignite then leave the flask at room temperature Transfer the absorbent into a volumetric flask Make up with deionized water Analyzed by ion chromatography End Of Report Page 5 Of 6

Test Conducted Number : TWNC00183563 Photo Page 6 Of 6

Test Report Number : TWNC00182662S1 Applicant: Littelfuse, Philippines Inc. Date : Dec 01, 2010 LIMA Technology Center, Lipa City, Malvar, Batangas This is to supersede report No. TWNC00182662 dated Nov 22, 2010 Sample Description: One (1) group of submitted samples said to be : Part Description : Epoxy Gold RoHS Part Number : 087234 Date Sample Received : Nov 17, 2010 Date Test Started : Nov 17, 2010 Test Conducted : As requested by the applicant, for details please refer to attached pages. Authorized By: On Behalf Of Intertek Testing Services Taiwan Limited K. Y. Liang Director This report shall not be reproduced except in full, without the written approval of the laboratory. Page 1 Of 6

Number : TWNC00182662S1 Test Conducted Testing Item Result (ppm) Gold Powder Heavy Metal Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr 6+ ) content Polybrominated Biphenyls (PBBs) Monobrominated Biphenyls (MonoBB) Dibrominated Biphenyls (DiBB) Tribrominated Biphenyls (TriBB) Tetrabrominated Biphenyls (TetraBB) Pentabrominated Biphenyls (PentaBB) Hexabrominated Biphenyls (HexaBB) Heptabrominated Biphenyls (HeptaBB) Octabrominated Biphenyls (OctaBB) Nonabrominated Biphenyls (NonaBB) Decabrominated Biphenyl (DecaBB) Polybrominated Diphenyl Ethers (PBDEs) Monobrominated Diphenyl Ethers (MonoBDE) Dibrominated Diphenyl Ethers (DiBDE) Tribrominated Diphenyl Ethers (TriBDE) Tetrabrominated Diphenyl Ethers (TetraBDE) Pentabrominated Diphenyl Ethers (PentaBDE) Hexabrominated Diphenyl Ethers (HexaBDE) Heptabrominated Diphenyl Ethers (HeptaBDE) Octabrominated Diphenyl Ethers (OctaBDE) Nonabrominated Diphenyl Ethers (NonaBDE) Decabrominated Diphenyl Ether (DecaBDE) Halogen Content Fluorine (F) Chlorine (Cl) 299 Bromine (Br) 47991 Iodine (I) Remarks: ppm = Parts per million based on weight of tested sample = mg/kg = Not detected Responsibility Of Chemist : Irene Chiou / Kevin Liu / Cathy Chen Date Sample Received : Nov 16, 2010 Testing Period : Nov 17, 2010 To Nov 22, 2010 Page 2 Of 6

Number : TWNC00182662S1 Test Conducted (Ⅱ) RoHS Requirement: Restricted Substances Cadmium (Cd) Content Lead (Pb) Content Mercury (Hg) Content Chromium VI (Cr 6+ ) Content Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ehters (PBDEs) Limits 0.01% (100ppm) The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for homogeneous material. (Ⅲ) Test Method: Testing Item Testing Method Reporting Limit Cadmium (Cd) 1.0:2008 in clause 8/9/10, by content microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. 2 ppm Lead (Pb) content 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and 2 ppm Mercury (Hg) content Chromium VI (Cr 6+ ) content Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ethers (PBDEs) Halogen Content determined by ICP-OES. 1.0:2008 in clause 7, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. 1.0:2008 in annex C, by alkaline digestion and determined by UV-Vis spectrophotometer. 1.0:2008 in annex A, by solvent extraction and determined by GC-MSD and further HPLC confirmation when necessary. 1.0:2008 in annex A, by solvent extraction and determined by GC-MSD and further HPLC confirmation when necessary. With reference to EN 14582:2007 by calorimetric bomb with oxygen and determined by ion chromatography Remark: Reporting limit = Quantitation limit of analyte in sample 2 ppm 1 ppm 5 ppm 5 ppm 50 ppm Page 3 Of 6

Number : TWNC00182662S1 Test Conducted (Ⅳ) Measurement Flowchart: Test For Cd/Pb/Hg/Chromium (VI)/PBBS/PBDES Contents Reference Standard: IEC 62321 edition 1.0:2008 Sampling/grinding or cutting Cd/Pb/Hg Metal Cr 6+ Polymers / electronics PBBs/PBDEs For different material, digest the sample with appropriate acid *1 Confirm the tested samples are totally dissolved By spot test Get 50cm 2 sample Negative *2 Weigh sample and add alkaline solution Definite temp. extraction Weigh sample and add organic solvent By Soxhlet extraction or Solvent extraction Make up with deionized water By boiling water extraction Cool and filter the extract Concentrate the extract and make up with organic solvent Analyzed by ICP-OES Analyzed by GC-MSD Make up with deionized water and add diphenylcarbazide solution Remarks: Analyzed by UV-VIS *1: List Of Appropriate Acid: Material Acid Added For Digestion Polymers HNO 3, HCl,HF,H 2 O 2, H 3 BO 3 Metals HNO 3, HCl,HF Electronics HNO 3, HCl,H 2 O 2, HBF 4 *2: If the result of spot test is positive, Chromium VI would be determined as detected. Page 4 Of 6

Number : TWNC00182662S1 Test Conducted (Ⅳ) Measurement Flowchart: Test For Halogen Content Reference Standard: EN 14582 Sampling/grinding or cutting Add absorbent in a calorimetric bomb & place weighed sample in equipment Fill the calorimetric bomb with oxygen Ignite then leave the flask at room temperature Transfer the absorbent into a volumetric flask Make up with deionized water Analyzed by ion chromatography End Of Report Page 5 Of 6

Number : TWNC00182662S1 Test Conducted Photo Page 6 Of 6