PC User s manual. Advanced Electronic/Air Column PC BOWERS METROLOGY page 1 /32 version E

Similar documents
Acceleration/Velocity/Displacement VIBRATION METER

OP-02 / OP-03 / OP-04

Acceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202

MPP5800 series - PANEL MOUNT PRINTERS. Options

AW/AHW Professional Weighing Scale. User Manual

GW Professional Weighing Scale. User Manual SNOWREX INTERNATIONAL CO., LTD. SRGW

Minute Impulse Clock Controller I01DN

VIBRATION TACHOMETER OPERATION MANUAL. 3 in 1. Model : VT Your purchase of this

POINTS OF CAUTION BEFORE USE...

Product Data Sheet KyoRack 2

Remote Display Unit. Installers Handbook Copyright 2001 AirSense Technology Ltd. LM Remote Display Unit Installers Handbook Issue 1.

Product Data Sheet KyoRack 4

MP3 Digital Voice Module Model No.: VCM-SD Rev.A3. Content

Single cam type. Double cam type. Grip force N. Type Model/size Stroke Screw type straight style. Screw type tee style

244241, Operation Manual Contents subject to change without notice. Version 1.0 Issue AA

O P E R A T I N G M A N U A L

BEFORE USE... POINTS OF CAUTION COMPONENT IDENTIFICATION INSTRUCTION MANUAL MODEL R7K4DH-1-DAC32D R7K4DH-1-DAC32D

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820

S Sapling INSTALLATION MANUAL FOR FIELD SELECTABLE ANALOG CLOCKS SAA SERIES SPECIFICATIONS. advanced time and control systems

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

MODEL: R7K4FML3. Remote I/O R7K4F Series. POWER INPUT DC power R: 24 V DC (Operational voltage range: ±10 %; ripple 10 %p-p max.)

SC125MS. Data Sheet and Instruction Manual. ! Warning! Salem Controls Inc. Stepper Motor Driver. Last Updated 12/14/2004

VIBRATION METER Acceleration & Velocity Model : VB-8201HA

Appendices. RS232 Commands. RS232 Connector. Pin No Specification 1 N/A 2 RXD 3 TXD 4 DTR 5 GND 6 DSR 7 RTS 8 CTS 9 N/A.

16 Input AC Block I/O Module

TitraLab 580 and 585. KF Titration Workstations. Reference Manual D21T083

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

No /06e. Technical Manual Multistage-Temperature-/Differential Controller TAR x700

QUANTUM CONCEPT. Swimming User s Manual

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820

32 Input AC Block I/O Module

MODBUS Protocol for CS141 network card families

Installation Instructions: ICON Anti-Condensate Controller

PAA-ANALYZERS PRINCIPLE OF OPERATION

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000

IDENTIFICATION STS400

MAN-SGY-012-V11 EC 5195 Fairford Electronics Ltd - Synergy Modbus RTU Programming Manual - 22nd February 2016 Page 1 of 59.

P300. Technical Manual I/Os, 240 solenoid drivers th Street, Davis, CA 95616, USA Tel: Fax:

Operating Instructions for Digital Manometer. Model: MAN-SD

PCAN-MicroMod Evaluation Kit. Test and Development Environment for the PCAN-MicroMod. User Manual

Ref: HLSR 16-PW; HLSR 32-PW; HLSR 40-PW-000; HLSR 50-PW-000,

Installation and Operation Manual. AllSync Plus Wired Clocks

T1 and E1 Feature Cards

xlogic SuperRelay is a compact and expandable CPU replacing mini PLCs, multiple timers, relays and counters.

CTC 155 / 350 / 660 Dry-block calibrator

HARTING D-Sub Selection Guide

Weather Station P03/3-Modbus-GPS for Modbus

Dual laser + type K thermometer INFRARED THERMOMETER

Digital Current Transducer HO-SW series I P N = A. Ref: HO 100-SW; HO 150-SW; HO 200-SW; HO 250-SW

WEIGHT INDICATOR WIDRA W90

MAU100 Series. 1W, Miniature SIP, Single & Dual Output DC/DC Converters MINMAX. Key Features

Meteorological Station P03/3-RS485-WAGO

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

Semi-automatic titrators PH-Burette. A great ph-meter with integrated burette. Incredible price! Infinite possibilities

ISSP User Guide CY3207ISSP. Revision C

User's Guide. DISTO online. Leica Geosystems

Process Instrumentation analyzers

TYPE RECALL 1 RECALL 2 RECALL 3 RECALL 4, 8 RECALL 5, 7 RECALL 6 FORMAT #23 #30 #0 #7 #23 #20 MODE RUN TRACK POINT RUN RUN INC PARITY BAUD

4 - Way Acceptance Low Maintenance Easy Installation Re - Programmable Flash ROM Auto Self -Adjusting Sensor System

ISEmax CAM40/CAS40. Technical Information

E2T0 DVP

HMS-5000 Manual. Product Name: HMS-5000 Hall Effect Measurement System with variable temperature from 80K to 350K. - Manual version: ver 5.

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006%

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER

SMPS-12 SERVICE MANUAL V2.00. Eclipse Use Switching Power Supply. Copyright 2001, RF Technology

Multi-function, economical instrument with 4 functions in the same casing. Accessibility and safety: large-dimension terminals Insulated circuits

RT9403. I 2 C Programmable High Precision Reference Voltage Generator. Features. General Description. Ordering Information.

PHOENIX CONTACT - 04/2016. Features

Creating Empirical Calibrations

Experiment A11 Chaotic Double Pendulum Procedure

MAU100 Series. 1W, Miniature SIP, Single & Dual Output DC/DC Converters MINMAX. Block Diagram. Key Features

MAIN PCB R10, 12k R31. 2) Now with the capacitors. C12,C7 C20 C6. 1N4148 D3, D5, D6 Zener 4v7 D1, D D4, D7 ferrites F1+, F2- 4) Transistors

Safety Precautions WARNING If critical situations that could lead to user s death or serious injury is assumed by mishandling of the product.

Drive electronics pq12

LOGIC CIRCUITS. Basic Experiment and Design of Electronics. Ho Kyung Kim, Ph.D.

RoHS. Versatile. X g. X 2 e

Distributing Tomorrow s Technologies For Today s Designs Toll-Free:

Data Logger V2. Instruction Manual

VELA. Getting started with the VELA Versatile Laboratory Aid. Paul Vernon

Grabber. Technical Manual

St art. rp m. Km /h 1: : : : : : : : : : : : :5 2.5.

Digital Torque Meter ADT-C Series OPERATION MANUAL

MAU200 Series. 1W, High Isolation SIP, Single & Dual Output DC/DC Converters MINMAX. Block Diagram. Key Features

Product manual. Mylos KNX Shutter actuator 2CSY1104C/S

IR 80-H. Non-Contact Infrared Temperature Sensor/Transmitter. Temperature Range: 500~1700

MODEL: MO Digital DC Milliohm Meter OPERATING INSTRUCTION

CALYS 80P. Field pressure calibrator with high accuracy 0.01%

PHASED OUT. FL ballasts Electronic dimming. PCA TC BASIC Y II, W BASIC compact

Bright Advance Corporation


Lasentec Product Group

Assembly and Operation Manual. April 2016

Flow control unit FCU-400

Karl-Fischer Titration the method for determining water

Grounding and Shielding

CANBUS-THERMO-2CH Rev B v Channel CAN-Bus Thermocouple Interface K-Type. V1.0 July SK Pang Electronics Ltd

CZ-53X Series IR Night Vision

Transcription:

User s manual Advanced Electronic/Air Column PC-2200 BOWERS METROLOGY page 1 /32 version 2.06 -E

BOWERS METROLOGY page 2 /32 version 2.06 -E

CONTENTS 1. INTRODUCTION 4 1.1 GENERAL INFORMATIONS 4 1.2 TECHNICAL SPECIFICATIONS 5 1.3 COLUMN DESCRIPTION 6 1.4 KEYPAD CONFIGURATION 7 1.5 STATUS PANEL 8 2. INSTALLATION 9 2.1 MECANICAL INSTALLATION 9 2.2 ELECTRICAL INSTALLATION 10 3. HOW TO USE IT 11 3.1 SWITCHING ON THE COLUMN 11 3.2 PROGRAMMING A SIMPLE MEASURE 12 3.3 PROGRAMMING A PART (EXAMPLE 1) 13 3.4 PROGRAMMING A DIAMETER 14 3.5 PROGRAMMING A PART (EXAMPLE 2) 15-16 3.6 THE CLASSIFICATION MENU 17 3.7 THE RS232 INTERFACE 18 3.8 LAYOUT OF IN/OUTPUT 19 4. FUNCTIONS 20 4.1 THE MEASURING MODE FUNCTIONS 20 4.2 THE PROGRAMMING MODE FUNCTIONS 21-22 4.3 CH-BUS APPLICATIONS 23 4.4 CH-BUS MECANICAL INSTALLATION 23 4.5 PROGRAMMING THE CH-BUS 24 5. PNEUMATIC INSTALLATION 25 5.1 THE A/E CONVERTER 26 5.2 HOW TO SETUP FOR A/E CONVERTER 27 6. GENERAL INITIALIZATION 28 6.1 TABLE OF DEFAULT VALUES 28 6.2 APPLICATION EXAMPLES 29 6.3 DIAMETER/THICKNESS 29 6.4 BLANK SETTING SHEET 30 7. GENERAL 31 7.1 TROUBLESHOOTING 31 7.2 MAINTENANCE 32 APPENDIX A. REPLACING EPROM & CPU APPENDIX B. MENU MAP BOWERS METROLOGY page 3 /32 version 2.06 -E

CHAPTER 1. INTRODUCTION 1.1 GENERAL INFORMATIONS - The column PC-2200 is an instrument system that measures and displays ID, OD, Length related measurements such as misalignment, and others in automotives, machines, electrical and electronic parts, and determines whether the measured results are acceptable or not. - The user can identify the measurement values correctly and easily as the display is made on a 3-Color LED Bar (green, orange, red) and a DOT MATRIX LED (8 characters) mounted in the front side. - The Status panel, positioned on the front bottom side, shows the current operating status in regards to the unit system (mm/inch) and operating sets (M1, M2, M3, M4) using 12 LED s (green). - The Keypad, consists of 9 membrane switches mounted below the Status panel, performs the user program such as the system setup. The user can build the program environment that can satisfy the user s requirements to the maximum through the Keypad operation such as selecting the menu in easy and free way and setting up the required variables. - The rear upper side is configured as the AC power switch, Fuse holder, AC power inlet and Aux. power supply, and therefore, it can use several units of PC-2200 through connecting with only one unit of power supply. The AC power of AC 110/230 V and 50/60 Hz is applied. You can select the power source of 110V/230V (default : 110V) by inserting the connector on the DC power PC board that is fixed on the upper side of the system inside. - With the 5 external interfaces on the rear center side, the column can be connected to another column, PC, Printer, PLC or CNC. - You can use the HBT, LVDT and CAPACITIVE probes as electronic system or AIR probes through the analog board on the rear bottom side. You should install the analog board (PCB) dedicated by the type of probe. - The PC-2200 is an integrated high quality measurement system that performs various measurements and display functions such as inter-channel operations up to 4 channels and dynamic mode in addition to the simple displays of measurement values. BOWERS METROLOGY page 4 /32 version 2.06 -E

1.2 TECHNICAL SPECIFICATIONS General : Storage temperature : -40 C to 60 C /- 40 F to 140 F Operational temperature : 0 C to 50 C / 32 F to 122 F Power supply : 110/230V (AC) 50/60Hz Max. consumption : 40VA Fuse : 2A delayed MTBF (Mean Time between Failure) : >100'000 hours Average life of display : > 50'000 hours Performance : Time for stabilization after switching ON Measurement thermal drift Measuring thermal drift between channels PC-2200 equiped with HBT-LVDT-CAP probes Measuring accuracy at 20 C / 68 F Resolution = 0.1 µm /.00001 : 5 minutes : 100PPM/ C : 30PPM/ C : ± 0.5% ± Resolution PC-2200 equiped with Air System in the nominal conditions Working range : ± 50µm /.002 Interfaces : Analog OUTPUT Range Full scale accuracy: : ± 5.0V F.S. : 2% of full scale Serial OUTPUT (RS 232) Type : RS 232 C Transmission speed (Baud rate) : 4800, 9600, 19200 Word length : 7 or 8 Parity control : NONE, EVEN, ODD DC-OUT Photo couplers Maximal Voltage Maximal Tension : 50V : 60mA Weight and Dimensions : Dimensions (height * width * depth) : 450 * 57 * 215mm / 17.7 *2.16 *8.66 Weight : 4.12 kg BOWERS METROLOGY page 5 /32 version 2.06 -E

1.3 COLUMN DESCRIPTION Front View Rear View Bar scale 3-color LED-bar(103ea) Green, orange, red ON-OFF Switch Fuse 2A AC power line input Auxiliary power line (for other column) Identification and serial numbers RS 232 C Interface External Control Interface Display (LED) (8 chr.) OUTPUT Interface (class) DC OUT Interface (V) CH-BUS Interface (signal transfer) Status panel 12 (LED) Keypad 9 Keys Internal View Identification analog board Analog board for (HBT, LVDT,CAPACITIVE,AIR) Top DC Power PCB Noise filter module Display (PCB) Main board PCB Front Rear Analog board PCB Bottom BOWERS METROLOGY page 6 /32 version 2.06 -E

1.4 KEYPAD CONFIGURATION Program Measuring mode Access to the programming mode Programming mode No function Move upward Measuring mode Select M1, M2, M3, M4 Programming mode Used to move from a specific menu to other menu, or to increase the values when setting the values of variables. Escape Measuring mode Initialization of dynamic mode Programming mode Escape to previous menu. Move left Measuring mode Send data Programming mode Used to move from a specific menu to other or move the selected LED to the next left LED Move right Measuring mode No function Programming mode Used to move from a specific menu to other or move the selected LED to the next right LED Calibration Measuring mode Calibration functions Programming mode No functions Preset Measuring mode Used to set the current measured values to 0 or pre-selected values (See page 20) Programming mode No function Move downward Measuring mode No function Programming mode Used to move from a specific menu to other menu, or to decrease the values when setting the values of variables. Measuring mode Instrument OFF + ON = Reset Programming mode Used to select the current menu or to set values of variables BOWERS METROLOGY page 7 /32 version 2.06 -E

1.5 STATUS PANEL Metric display (mm) Inch display Range ±1000µm / ±1 mm Range ±500µm / ±0.5 mm Range ±100µm / ±0.1 mm Range ±50µm / ±0.050 mm Range ±10µm / ±0.01 mm Range ±5µm / ±0.005 mm Range ± 0.05 inch Range ± 0.01 inch Range ± 0.005 inch Range ± 0.001 inch Range ± 0.0005 inch Range ± 0.0001 inch Measure number BOWERS METROLOGY page 8 /32 version 2.06 -E

Chapter 2. Installation 2.1 MECHANICAL INSTALLATION Fix the column on the aluminum base and lock it with the 2 screws (M6 x16) Connect the power supply cable (A). Connect the probe cable to the analog board (B) Switch (ON) I. A B BOWERS METROLOGY page 9 /32 version 2.06 -E

2.4 ELECTRICAL INSTALLATION Switching the Voltage from 230V(110V) to 110V(230V). Remove the cover by unscrewing the 8 screws. Move the connector A on 110V or 230V. A Power supply (PCB) (Default) 220V 0V 110V 3P- Male Transformer to noise filter module 2P-female BOWERS METROLOGY page 10 /32 version 2.06 -E

Chapter 3. HOW TO USE IT 3.3 SWITCHING ON THE COLUMN To start the first time, we advise to make a general RESET. Press + ON simultaneously, B O W E R S R E S E T... - 1. 0 4 0 0 Do not release your pressure on program will start. The default parameters are : before the message RESET appears on the display, then a test CHANNEL : Source : Ext. - CH-A Ratio :1.000 Direc. + MEASURE : M1 Bar :Bottom B.fact. 1.00 Range : ± 0.05 Sens : 1.000 Resol.:0.00005 Func: A Mode: STATIC SPEC. : M1 NOMI. 000.0000 - -TOLER 0.0500 - +TOLER +0.0500 APPROCH 0.0500 + APPROCH : +0.0500 MASTER : M1 - -MASTER +0.00000 +MASTER +0.00000 CLASS : OFF RS232 : SPEED 9600, DATA 8, PARITY N, TERM CRLF, RTS ON, PRINT BRIEF, RSMODE PRINT ID NO. 000 ETC : GENERAL UNIT INCH, DISPLAY mm, INPUT HBT, P/W PROGRAM 0000, CALIBR OFF AVERAGE BAR 005, DIGIT 005, A/D 20 VERSION V2.xx The above parameters are the default values, so it is necessary to modify the values according to your application. Description of functions per menu CHANNEL : Select the source and the probes used with ratio and measuring direction. MEASURE : Select the starting position of the bar, Bar factor, Range of the Bar, Resolution of the digital display, Combination of probes, Static or Dynamic measuring mode. SPEC. MASTER CLASS RS232 : Store the nominal size, the upper tolerance, the lower tolerance, the upper warning limit, the lower warning limit of the component to be measured. : Store the lower master value and the upper master value used. : Active the classification mode, class number, starting value, class range. : Select the transmission speed, word length, parity control, end of characters, request to send signal, printing mode, simplex or duplex mode, identity number. ETC GENERAL : Select the unit (mm or inch), type of display (mm or um), type of probes used, program and calibration password. AVERAGE : Select the bar sensitivity, the display sensitivity, the analog board sensitivity. VERSION : Show the software version. BOWERS METROLOGY page 11 /32 version 2.06 -E

3.2 PROGRAMMING A SIMPLE MEASURE Example N 1 Measure a component with a HBT probe connected to channel A. Component 20.000mm ± 0.005 USING a HBT probe, we do not use the calibration, this mode will be explained in a subsequent chapter. Master 20.0000mm Step n 1 is to place the probe into a correct position to be able to get the maximum range and the minimum deviation. Place the master 20.0000 mm on the stand, place the probe into position. Press simultaneously S A D J U S T C H - A - 1. 0 5 0 0 Move the probe down to the electro-mechanical zero, - 0. 0 0 1 0, then approximately stop around zero, lock the probe. Press Esc to escape to the measuring mode. Parameters to be changed for example number 1 MEASURE : M1 Range : ± 0.01mm Resol.:0.0002mm SPEC. : M1 NOMI. 020.0000 - -TOLER 0.0050 - +TOLER +0.0050 APPROCH 0.0040 + APPROCH : +0.0040 BOWERS METROLOGY page 12 /32 version 2.06 -E

3.3 PROGRAMMING A PART (EXAMPLE 1) Press (2 sec.) P / W 0 0 0 0 C H A N N E L M E A S U R E Prog M 1 S E L E C T B A R B. F A C T R A N G E ± 1. 0 ± 0. 5 ± 0. 1 ± 0. 0 5 ± 0. 0 1 ± 0. 0 0 5 R A N G E S E N S. R E S O L. 0. 0 0 1 0. 0 0 0 5 0. 0 0 0 2 R E S O L. Esc M 1 Esc M E A S U R E S P E C. M 1 N O M I. 0 0 0. 0 0 0 0 S M 0 2 0. 0 0 0 0 N O M I. - T O L E R - 0. 8 0 0 0 S M - 0. 0 0 5 0 - T O L E R + T O L E R + 0. 8 0 0 0 + 0. 0 0 5 0 S M + T O L E R - A P P R O - 0. 8 0 0 0 S M - 0. 0 0 4 0 - A P P R O + A P P R O + 0. 8 0 0 0 S M + 0. 0 0 4 0 M 1 S P E C. Esc Esc Esc S A V E? Place the master 20.0000mm in contact with the probe, then press Preset P R E S E T Upper tolerance Upper approach limit Nominal value The approach limit should be within the tolerance. Lower approach limit Lower tolerance BOWERS METROLOGY page 13 /32 version 2.06 -E

3.4 PROGRAMMING A DIAMETER Measurement of a diameter with a HBT probe connected to channel A. Component 15.000 mm ± 0.002 Min master 14.9988mm Max. master. 15.0026mm Step n 1 is to place the probe into a location to be able to get the maximum range and the minimum deviation. Place the measuring head of 15.0000 mm in the master, Press simultaneously S A D J U S T C H - A - 1. 0 5 0 0 Move the probe down to the electro-mechanical zero. - 0. 0 0 1 0, then approximately stop around zero, lock the probe. Press Esc to escape to the measuring mode. Parameters to be changed for example number 2 CHANNEL : Direc. - MEASURE : M1 Range : ± 0.005 mm Resol.: 0.0001mm SPEC. : M1 NOMI. 015.0000 - -TOLER 0.0020 - +TOLER +0.0020 APPROCH 0.0016 + APPROCH : +0.0016 MASTER : M1 - -Master : 14.9988mm - +Master : 15.0026mm BOWERS METROLOGY page 14 /32 version 2.06 -E

3.5 PROGRAMMING A PART (EXAMPLE 2) Press (2 sec.) P / W 0 0 0 0 Prog C H A N N E L S O U R C E C H - A R A T I O D I R E C + - D I R E C Esc C H - A Esc C H A N N E L M E A S U R E M 1 S E L E C T B A R B. F A C T R A N G E ± 1. 0 ± 0. 5 ± 0. 1 ± 0. 0 5 ± 0. 0 1 ± 0. 0 0 5 R A N G E S E N S. R E S O L. 0. 0 0 1 0. 0 0 0 5 0. 0 0 0 2 0. 0 0 0 1 R E S O L. Esc M 1 Esc M E A S U R E S P E C. M 1 N O M I. 0 0 0. 0 0 0 0 S M 0 1 5. 0 0 0 0 N O M I. - T O L E R - 0. 8 0 0 0 S M - 0. 0 0 2 0 - T O L E R + T O L E R + 0. 8 0 0 0 + 0. 0 0 2 0 S M + T O L E R - A P P R O - 0. 8 0 0 0 S M - 0. 0 0 1 6 - A P P R O + A P P R O + 0. 8 0 0 0 S M + 0. 0 0 1 6 M 1 S P E C. Esc Esc M A S T E R M 1 - M A S T E R 0 1 5. 0 0 0 0 S M 0 1 4. 9 9 8 8 - M A S T E R + M A S T E R 0 1 5. 0 0 0 0 S M 0 1 5. 0 0 2 6 + M A S T E R Esc M 1 Esc M A S T E R Esc S A V E? BOWERS METROLOGY page 15 /32 version 2.06 -E

The Calibration Example N 2 The parameters are now stored. The automatic calibration can be started. Min. master 14.9988mm Max.master 15.0026mm Cal C A L.. M 1 C A L. place the measuring head in the lower master. C A L. place the measuring head in the upper master. 0. 9 8 1 The sensitivity is calculated automatically. If the message M I N O V E R then the calculated value. appears, that means that the value between the two masters is bigger Cal C A L.. M 1 M O D U L E M 1 C A L % V A L U E 0 0 0 % NONE : All sensitivity values are allowed. 000% : The sensitivity value will not be accepted if the calculated value during the calibration is different from the stored value. XXX% : The sensitivity value will not be accepted if the calculated value during the calibration is different from XXX% of the stored value. After the calibration the measurement can be started. BOWERS METROLOGY page 16 /32 version 2.06 -E

3.6 THE CLASSIFICATION MENU CLASS The class menu is used separately. Example : Pin dia. 10mm - 0 +0.100mm to be classified by steps of 0.005mm, in 20 classes, starting from 10.0000 mm. (2 sec) P / W Prog C H A N N E L M E A S U R E S P E C. M A S T E R C L A S S S E L E C T O F F O N S E L E C T N U M B E R M 0 1 0 S M 0 2 0 N U M B E R S T A R T 0 0 0. 0 0 0 0 S M 0 1 0. 0 0 0 0 S T A R T S T E P 0 0 0. 0 1 0 0 S M 0 0 0. 0 0 5 0 S T E P Esc C L A S S Esc S A V E? O K C measure the first pin C 5 The first pin will be classified into class 5, and the printed value will be between 10.025 and 10.030 mm To escape from the Class menu, SELECT. OFF BOWERS METROLOGY page 17 /32 version 2.06 -E

PC-2200 3.2 THE RS232 INTERFACE The RS 232 Interface allows to send the data to a printer, as well to a PC, also allows to modify the stored parameters in the column with the help of the communicator software. How to connect a PC-2200 to a serial printer. The most important to connect a column to a printer or a computer is the adjustment of parameters. The first values to be known are the serial printer parameters. e.g. : 4800 bauds, 7 bits, parity even. adjustment How to setup the column? Prog (2 sec.) P / W 0 0 0 0 MAS T ER S PE C. C LA S S 9 60 0 S PE E D D AT A P AR I T Y N ON E M T ERM C R M R TS P R I N T B R I E F R SMO D E P R I N T I D N O. S AV E? Press S ID NO :000 MEA S URE C HA N NE L M 8 R S2 3 2 4 80 0 S PE E D D AT A E VE N P AR I T Y C RL F T ERM R TS P R I N T Esc R S2 3 2 7 M ON O F F F U L L 0 0 0 2. 0 0 0 0 R SMO D E I D N O. Esc S END... M1 :+ 2.000mm OK ID NO :000 BOWERS METROLOGY page 18 /32 M1 :+ 2.000mm OK version 2.06 -E

3.1 LAYOUT OF IN/OUTPUT 1 2 3 4 5 6 7 8 9 RS-232 C Pin# Functions 1 * (not connected) 2 Rxd 3 Txd 4 Vcc 5 Gnd 6 * (not connected) 7 Rts 8 Cts 9 Gnd (Connection of a serial printer or a PC) In the case of RS232-RS mode is set as PRINT, the display value is printed via the RS232 by connecting the pins #1,9 of external control.. If the RS 232-RS mode is set as «HOST», the communication becomes (duplex) and allows to use the communicator software. 1 2 3 4 5 6 7 8 9 EXT.CON Pin# Functions 1 RS 232 sortie (0.5 sec.) 2 Current value display 3 Dynamic/Static 4 M1->M2->M3->M4 5 Hold measure 6 * (not connected) 7 * (not connected) 8 * (not connected) 9 Gnd The external control functions can be activated by connecting the pins #1 to 5 to the pin #9(GND) according to the required function. The following functions can be activated by connecting the pin #9 to pin # (foot pedal, box) #1)Print the display value. #2) Change dynamic mode to static mode #3) Reset the dynamic mode (min., max.) #4) Move the measurement mode (M1) to M2, M2,M3,M4 should be active. (ON) #5) Freeze the displayed value. Active the preset mode by connecting the pin #3 and #5 simultaneously 1 2 3 4 5 1 2 3 4 5 6 7 8 9 6 7 8 9 OUTPUT DC OUT Pin# Functions Class Mode (Binary) 1 O.K (Green) Bit 0 2 * (not connected) Bit 1 3 Approch + (Orange) Bit 2 4 +N.G (Red) Bit 3 5 * (not connected) Bit 4 6 Approch (Orange) Bit 5 7 -N.G (Red) Bit 6 8 Drive Voltage 9 Gnd Pin# Functions 1 D/A sortie 2 * (not connected) 3 * (not connected) 4 * (not connected) 5 * (not connected) 6 * (not connected) 7 * (not connected) 8 * (not connected) 9 Gnd Active the contact with GND pin#9 when the value of the bar is positioned in the corresponding range pins #1, 3, 4, 6, 7). This application shows if the product is acceptable or not with an external unit such as lamps, relays, by powering the pins #8,9. If the Class mode is turned on, the judgement mode(ok, +/-NG, etc.) is automatically turned off and the data is output with BCD code through the same port(each pin).(refer to the chapter 3.6 for setting up.) Analog output of the display (Signal Voltage (pin #1 and #9). The voltage range is : Approx. ±4.3V with ±1 mm, or ±0.05 inch 1 2 3 4 5 6 7 8 9 CH-BUS Pin# Functions 1 Ex-A 2 Ex-B 3 Ex-C 4 Ex-D 5 Gnd 6 * (not connected) 7 * (not connected) 8 * (not connected) 9 Gnd This function is used when the signal of a probe should be shifted to a second column. Application : Example : Display a maximum value on 1 column and a minimum value to the other column with only one probe.. The analog board of the column which is receiving the data should be disconnected,. Circuit connection diagram (OUTPUT) CH-Bus diagram #9 GND #4 #3 #1 #6 #7 E Red (bigger value than TOLER+) Orange (Value between APPRO+ and TOLER+) Green (Value between APPRO- and APPRO+) Orange (Value between APPRO- and TOLER-) Red (smaller value than TOLER-) Probe input Analog board PCB A B C D A/E-Converter EX-A (pin #1) EX-B (pin #2) EX-C (pin #3) EX-D (pin #4) E=External voltage Display controller BOWERS METROLOGY page 19 /32 version 2.06 -E

Chapter 4. Functions Definition of keypad functions per menu 4.1 THE MEASURING MODE FUNCTIONS Prog Access to programming mode Functions Functions M M Change the measure number (M1-M2) only if M2,M3,M4 (ON) M1-M2-M3-M4 Esc S S send the displayed value to RS232 No function in measuring mode No function in measuring mode Simultaneously when switching (ON) RESET Preset Cal Preset Value M1 00.0000 Calibration Module M1, M2, M3,M4 CAL% Access to preset mode Value = Norm. value + Meas. range. Cal. Min and Max Cal. by measure M1, M2, M3, M4 NONE, Value XXX% PRESET Maximum +/- 0.05 4.2 THE PROGRAMMING MODE FUNCTIONS Prog Menu Sub-menu Functions Functions Functions Functions CHANNEL SOURCE CH-A CH-B CH-C CH-D EXT. CH-BUS RATIO RATIO RATIO RATIO 1.000 1.000 1.000 1.000 DIRECT DIRECT DIRECT DIRECT + / - + / - + / - + / - SOURCE : EXT. Select the source of the probe on the analog board on this column. CH-BUS. Select the source of the probe from another column thru the CH-BUS. CH-A : Select the ratio value and measuring direction for the channel A. CH-B : Select the ratio value and measuring direction for the channel B. CH-C : Select the ratio value and measuring direction for the channel C. CH-D : Select the ratio value and measuring direction for the channel D. BOWERS METROLOGY page 20 /32 version 2.06 -E

Prog Menu Sub-menu Functions Functions Functions MEASURE M1 ON BAR B. FACT RANGE M2, M3, M4 ON/OFF SENS. RESOL. FUNC MODE. BOTTOM,CENTER,-10->0 1.00 ± 0.05, ±0.01, ±0.005, ± 0.001, ± 0.0005, ±0.0001 1.000 0.005,0.001,0.0005,0.0001,0.00005, 0.00002, 0.00001 A,B,C,D,A+B,A-B,C+D,(A+B)-C, (A+B+C)/3,(A+B+C+D)/4, (A+B)-(C+D) STATIC,MAXIMUM,MINIMUM, (M+m)/2,(M-m)/2,M-m. M1,M : Select the characteristics of the measuring result M1, it is possible to store 4 different measuring results (M1, M2, M3, M4). M2, M3, M4 should be (ON) BAR : Select the starting position of the LED-bar, (BOTTOM) start from bottom, (CENTER) start from center, (-10->0) start from an excentred position in case of being out of range with the LED bar. B.FACT : Bar multiplication factor, giving the possibility of adjusting several column at the same level. RANGE : Select the measuring range. SENS : Calculated sensitivity value after calibration. RESOL : Select the measuring resolution.. FUNC : Select the setting of measurement. MODE : Select the dynamic or static mode Prog Menu Sub-menu Functions Functions Functions SPEC. M1 M2 NOMI. -TOLER +TOLER -APPRO +APPRO 0.00000-0.05 +0.05-0.05 +0.05 M1,M.. : Store in measurement number 1, 2, 3, 4. NOMI. : Store the nominal size -TOLER : Store the lower tolerance. +TOLER : Store the upper tolerance. -APPRO : Store the lower warning limit. +APPRO : Store the upper warning limit. Prog Menu Sub-menu Functions Functions Functions MASTER M1 M2 -MASTER +MASTER.. +0.00000 +0.00000 M1,M : Store in measurement number 1, 2, 3, 4. -MASTER : Store the lower master value. +MASTER : Store the upper master value. BOWERS METROLOGY page 21 /32 version 2.06 -E

Prog Menu Sub-menu Functions Functions Functions CLASS Select ON/OFF NUMBER START STEP 000 +0.0000 0.0000 CLASS : Switch ON or OFF the class menu. NUMBER : Store the number of classes to be used. START : Store the starting nominal value STEP : Store the step value of the class. Prog Menu Sub-menu Functions Functions Functions RS232 SPEED DATA PARITY TERM RTS PRINT RSMODE ID NO. 4800,9600,19200 BAUD RATE 7,8 Bits NONE, ODD,EVEN CRLF / CR ON / OFF BRIEF / FULL PRINT /HOST 000 SPEED : Select the transmission speed. DATA : Select the word length. PARITY : Select the parity control : none, even, odd TERM : Select the end characters : CR, CRLF RTS : (Request to Send) request to send a signal PRINT : Select the printing mode, (BRIEF) send the minimum data, (FULL) send a complete protocol. RS232 : Select the RS232 Interface in mode PRINT(Simplex) or HOST (Duplex) ID NO : Store an identity number. Prog Menu Sub-menu Functions Functions Functions ETC GENERAL UNIT DISPLAY INPUT P/W AVERAGE VERSION BAR DIGIT A/D PROGRAM CALIBR. METRIC, INCH mm or um HBT,LVDT,CAP_1,CAP_5,AIR 0000 ON/OFF 0000 005 005 20 v 2.xx BMI GENERAL : Select the measuring unit, select the display (mm or um), select the analog board used, store a PROGRAM password and a CALIBRATION password. AVERAGE : BAR, Store a filter for the bar. DIGIT, Store a filter for the digital display. A/D, Store a filter for analog/digital converter. VERSION : Show the software version. When changing the unit(metric to inch or inch to metric) it will be automatically out of the program without saving or confirming. The user should check the specification input after going into the program again. BOWERS METROLOGY page 22 /32 version 2.06 -E

PC-2200 4.3 CH-BUS APPLICATIONS The CH-BUS channel transfers a data signal to another column. Application. Component 0.002 15.000mm ± 0.007 1 probe We need to see 2 values simultaneously. 1. Diameter 15.0000mm 2. max T.I.R 0.002mm Dia. Max-min Min.master. 14.9988mm Max.master 15.0026mm 4.4 CH-BUS MECHANICAL INSTALLATION Column n 2 Column n 1 Power supply cable Cable PC-2302 The receptive column should have the analog board removed. Cable PC-2352 Probe cable Analog board Column without analog board (Blank back cover PC-2009) BOWERS METROLOGY page 23 /32 version 2.06 -E

4.5 PROGRAMMING THE CH-BUS The column n 1 should be programmed like example n 2 on page n 15 Programming column n 2 Prog P / W 0 0 0 0 C H A N N E L S O U R C E E X T. C H - B U S S O U R C E Esc C H A N N E L M E A S U R E M 1 S E L E C T B A R B. F A C T R A N G E ± 1. 0 ± 0. 5 ± 0. 1 ± 0. 0 5 ± 0. 0 1 ± 0. 0 0 5 R A N G E S E N S. R E S O L. 0. 0 0 1 0. 0 0 0 5 0. 0 0 0 2 0. 0 0 0 1 R E S O L. F U N C. M O D E S T A T I C M - m M O D E Esc M 1 Esc M E A S U R E S P E C. M 1 N O M I. 0 0 0. 0 0 0 0 S M 0 0 0. 0 0 0 0 N O M I. - T O L E R - 0. 0 0 0 0 S M - 0. 0 0 0 0 - T O L E R + T O L E R + 0. 0 0 0 0 + 0. 0 0 2 0 S M + T O L E R - A P P R O - 0. 8 0 0 0 S M - 0. 0 0 1 6 - A P P R O + A P P R O + 0. 8 0 0 0 S M + 0. 0 0 1 6 M 1 S P E C. Esc Esc Esc S A V E? 0. 0 0 0 0 Column n 1 Column n 2 1 5. 0 0 0 0 0. 0 0 0 0 Diameter 15.0000 mm T.I.R 0.0020 mm BOWERS METROLOGY page 24 /32 version 2.06 -E

Chapter 5. PNEUMATIC INSTALLATION 1. Fix the column and the converter on the aluminum base. 2. Fix the hose of the air probe to nipple of converter. Hose nipple for the air probe 3. Connect the cable PC-2332 between the converter and the analog board. 4. Connect the air supply hose to the hose nipple on the converter. Air supply hose nipple Connection cable PC-2332. Not less than 3 bar of air should be supplied. BOWERS METROLOGY page 25 /32 version 2.06 -E

5.1 THE A/E CONVERTER < Front View> <Rear View> <Internal View> (View) (Diagram) The programming procedure is similar to an electronic probe. BOWERS METROLOGY page 26 /32 version 2.06 -E

5.2 HOW TO SETUP FOR A/E CONVERTER A. BALANCE B. PRESSURE E. SIGNAL C. GAGE D. AIR IN It is necessary to adjust the A/E CONVERTER in order to use this Column optimally. 1) Pressure Adjustment(STANDARD : 2 ± 0.1bar) - Connect PRESSURE GAUGE to C. - Connect AIR(Min. 3 bar) to D. - Adjust pressure by turning B with screw driver. Default pressure is 2 bar(factory setting). 2) Balance adjustment - Connect the A/E converter and the Column with cable(pc-2332). - Connect the air gauge to C. - Stop supplying D with air. - Preset the Column to 0 with the PRESET key. - Place the air gauge into the Min. Master. - Supply D with air. - Adjust A with screw driver. 예 ) Example) Min. Master value : -0.020mm DISPLAY VALUE : -0.020mm In case of unbalance, measuring range could be narrow. BOWERS METROLOGY page 27 /32 version 2.06 -E

Chapter 6. GENERAL INITIALIZATION (1) Function: Initialize all stored data to the default values. CAUTION : All your stored data will be erased. Press + ON 6.1 TABLE OF DEFAULT VALUES Menu Sub-menu Selection Functions Choice Default value CHANNEL SOURCE EXT. EXT. CH-BUS CH-A RATIO 0-5.000 1.000 DIREC. + / - + CH-B RATIO 0-5.000 1.000 DIREC. + / - + CH-C RATIO 0-5.000 1.000 DIREC. + / - + CH-D RATIO 0-5.000 1.000 DIREC. + / - + MEASURE M1 SELECT ON ON BAR BOTTOM CENTER -10->0 B.FACT -5.00 / +5.00 1.00 BOTTOM RANGE ± 0.05 ± 0.05 ± 0.01 ± 0.005 ± 0.001 ± 0.0005 ± 0.0001 SENS. ± 0.01 ~ 5.000 1.000 RESOL. 0.005, 0.001, 0.0005, 0.0001, 0.00005, 0.00002, 0.00001 FUNC MODE A, B, C, D, A+B, A-B, C+D, (A+B)-C, (A+B+C)/3, (A+B+C+D)/4 (A+B)-(C+D) STATIC, MAXIMUM, MINIMUM,(M+m)/2, (M-m)/2, M-m 0.00005 A STATIC SPEC. M1 NOMI. 000.0000 0.00000 -TOLER. -0.0000-0.05 +TOLER +0.0000 +0.05 -APPRO -0.0000-0.05 +APPRO +0.0000 +0.05 MASTER M1 -MASTER +0.0000 +0.0000 +MASTER +0.0000 +0.0000 CLASS SELECT OFF / ON OFF NUMBER 1-100 010 START +0.0000 +0.00000 STEP 0.0000 0.001 RS232 SPEED 19200, 9600, 4800 9600 DATA 7, 8 8 PARITY None,even,Odd None TERM CR,CRLF CRLF RTS ON / OFF ON PRINT BRIEF, FULL BRIEF RSMODE PRINT,HOST PRINT ID NO. 000 000 ETC GENERAL UNIT METRIC,INCH INCH DISPLAY Mm, um mm INPUT HBT,LVDT,CAP,AIR HBT P/W PROGRAM 0000 CALIBR. ON/OFF OFF AVERAGE BAR 000 005 VERSION DIGIT 000 005 A/D 00 20 V2.xx BOWERS METROLOGY page 28 /32 version 2.06 -E

6.2 APPLICATION EXAMPLES 6.3 DIAMETER/THICKNESS A B <Initialisation> <Specification of the measure> External diameter : 10.000 mm Lower tolerance : - 20µm Upper tolerance: +20µm Lower warning limit: - 15µm Upper warning limit: +15µm Lower master : 9.980 mm Upper master : 10.020 mm Unit : mm Menu Sub-menu Selection Function Choice Values CHANNEL SOURCE EXT. EXT. CH-BUS CH-A RATIO 0-5.000 1.000 DIREC. + / - + CH-B RATIO 0-5.000 1.000 DIREC. + / - + CH-C RATIO 0-5.000 1.000 DIREC. + / - + CH-D RATIO 0-5.000 1.000 DIREC. + / - + MEASURE M1 SELECT ON ON BAR BOTTOM CENTER CENTER -10->0 B.FACT -5.00 / +5.00 1.00 RANGE ± 1.0mm ± 0.5mm ± 0.1mm ± 0.05mm ± 0.05mm ± 0.01mm ± 0.005mm SENS. ± 0.01 ~ 5.000 1.000 RESOL. 0.01, 0.005, 0.001, 0.0005, 0.0002, 0.0001 FUNC MODE A, B, C, D, A+B, A-B, C+D, (A+B)-C, (A+B+C)/3, (A+B+C+D)/4 (A+B)-(C+D) STATIC, MAXIMUM, MINIMUM,(M+m)/2, (M-m)/2, M-m 0.001 A+B STATIC SPEC. M1 NOMI. 000.0000 010.000 -TOLER. -0.8000-0.0200 +TOLER +0.0000 +0.0200 -APPRO -0.0000-0.0150 +APPRO +0.0000 +0.0150 MASTER M1 -MASTER +00.0000 +9.9800 +MASTER +00.0000 +10.0200 CLASS SELECT OFF / ON OFF NUMBER 1-100 010 START +00.0000 +00.0000 STEP 0.0000 0.0100 RS232 SPEED 19200, 9600, 4800 9600 DATA 7, 8 8 PARITY None,even,Odd None TERM CR,CRLF CRLF RTS ON / OFF ON PRINT BRIEF, FULL BRIEF RSMODE PRINT,HOST PRINT ID NO. 000 000 ETC GENERAL UNIT METRIC,INCH METRIC DISPLAY mm, um mm INPUT HBT,LVDT,CAP,AIR HBT P/W PROGRAM 0000 CALIBR. ON/OFF OFF AVERAGE BAR 000 003 DIGIT 000 003 A/D 00 10 VERSION V2.00 BOWERS METROLOGY page 29 /32 version 2.06 -E

6.4 BLANK SETTING SHEET <Initialisation> <Specification of the measure> Nominal size : Lower tolerance: Upper tolerance: Lower warning limit: Upper warning limit: Lower master : Upper master: Unit : mm Menu Sub-menu Selection Function Choice Values CHANNEL SOURCE EXT. CH-BUS CH-A RATIO 0-5.000 DIREC. + / - CH-B RATIO 0-5.000 DIREC. + / - CH-C RATIO 0-5.000 DIREC. + / - CH-D RATIO 0-5.000 DIREC. + / - MEASURE M1 SELECT ON BAR BOTTOM CENTER -10->0 B.FACT -5.00 / +5.00 RANGE ± 1.0mm ± 0.5mm ± 0.1mm ± 0.05mm ± 0.01mm ± 0.005mm SENS. ± 0.01 ~ 5.000 RESOL. 0.01, 0.005, 0.001, 0.0005, 0.0002, 0.0001 FUNC MODE SPEC. M1 NOMI. 000.0000 -TOLER. -0.8000 +TOLER +0.0000 -APPRO -0.0000 +APPRO +0.0000 MASTER M1 -MASTER +00.0000 CLASS SELECT OFF / ON +MASTER +00.0000 NUMBER 1-100 START +00.0000 STEP 0.0000 RS232 SPEED 19200, 9600, 4800 DATA 7, 8 PARITY TERM RTS PRINT RSMODE ID NO. 000 None,even,Odd CR,CRLF ON / OFF BRIEF, FULL PRINT,HOST ETC GENERAL UNIT METRIC,INCH DISPLAY mm, um INPUT HBT,LVDT,CAP,AIR P/W AVERAGE BAR 000 VERSION DIGIT 000 A/D 00 PROGRAM CALIBR. A, B, C, D, A+B, A-B, C+D, (A+B)-C, (A+B+C)/3, (A+B+C+D)/4 (A+B)-(C+D) STATIC, MAXIMUM, MINIMUM,(M+m)/2, (M-m)/2, M-m ON/OFF BOWERS METROLOGY page 30 /32 version 2.06 -E

Chapter 7. General 7.1 TROUBLE SHOOTING Default Actions The digital display & LED display are off. Check the power(ac 110) Check the fuse(2a) Check the power switch(on) position The digital display is off. Reset the column.( key + Power ON) The digital display & LED display are not moving. Check the probe position Check the connection of probe & column. Check the connection of main board & analog board. The function M2, M3, M4 do not work The functions M2, M3, M4 must be turned ON at MEASURE menu. The calibration is refused OVER MINIMUM One or a few data are not compatible between the specification values and the master values. BOWERS METROLOGY page 31 /32 version 2.06 -E

7.2 MAINTENANCE Please do not forget that this measuring instrument must be treated with care. Take notice that this User s manual is in relation with the software version V.2.00. Please do not hesitate to contact us if you need further assistance. BOWERS METROLOGY page 32 /32 version 2.06 -E

Menu Map for PC2200(V2.xx) BN20914 YES(ENTER) SAVE? NO(ESC) Prog P/W CHANNEL MEASURE SPEC MASTER CLASS RS232C ETC. > 2 sec (xxxx) SOURCE EXT. M1 SELECT ON M1 NOMI. e M1 - MASTER d SELECT OFF SPEED 4800 GENERAL UNIT METRIC CH-BUS OFF ON 9600 INCH - TOLER f + MASTER d 19200 Preset PRESET VALUE CH-A RATIO= 0 ~ 5.000 BAR BOTTOM CLASS_No 4~100 DISPLAY mm >0.5 sec " CENTER + TOLER f M2 - MASTER d DATA 7 μm M1 a DIREC.= + -10 0 START g 8 - -APPRO f + MASTER d INPUT HBT M2 a " B.FACT 0.1 ~ 5.00 STEP h PARITY NONE LVDT CH-D RATIO= 0 ~ 5.000 +APPRO f M3 - MASTER d ODD CAP_1 M3 a RANGE b EVEN CAP_5 DIREC.= + M2 NOMI. e + MASTER d AIR M4 a - SENS. ±0.010~5.000 TERM CRLF - TOLER f M4 - MASTER d CRLF P/W PROGRAM **** OR RESOL c + TOLER f + MASTER d RTS ON CAL.P/W OFF Cal P/W CAL..M(X) MOUDLE CAL% CH-EA RATIO= 0 ~ 5.000 FUNC A OFF ON **** >0.5 sec (xxxx) " B -APPRO f AVERAGE BAR 2~50 CAL_ M1 NONE DIREC.= + C PRINT BRIEF - D +APPRO f FULL DIGIT 2~50 CAL M2 VALUE 000% " A+B CH-ED RATIO= 0 ~ 5.000 A B M3 NOMI. e RSMODE PRINT A/D 2~20 xxxx M3 C+D HOST DIREC.= + (A+B)-C - TOLER f VERSION V 2.xx xxxx M4 - (A+B+C)/3 ID_NO 0~255 (A+B+C+D)/4 + TOLER f (A+B)-(C+D) + ADJUST -APPRO f >0.5 sec MODE STATIC CH-A xxxx MAXIMUM +APPRO f " MINIMUM " (M+m)/2 M4 NOMI. e CH-D xxxx (M-m)/2 M-m - TOLER f CH-EA xxxx " M2 Same as M1 map + TOLER f Key " CH-ED xxxx M3 Same as M1 map -APPRO f Left/Right Key + Power S/W Initialization of setup data M4 Same as M1 map +APPRO f Up/Down Key Esc Retun to upper menu in setup mode Reset in dynamic mode S Data sending(digital display Value) M M1~M2~M3~M4 Transfer (Toggle key)