Research Article Design and Research of a New Thermostatic Valve

Similar documents
Analysis of flow characteristics of a cam rotor pump

Research Article Finite Element Analysis of Flat Spiral Spring on Mechanical Elastic Energy Storage Technology

Design of Integrated Error Compensating System for the Portable Flexible CMMs

Modeling and Simulation of Cigarette Weight Control System

DESIGN OF A NOVEL HAND-HELD PNEUMATIC VACUUM PAD USING CFD

1917. Numerical simulation and experimental research of flow-induced noise for centrifugal pumps

Study on the Pressure and Temperature Distribution of Solid-Plug Conveying Element on Centrifugal Extruder

Static temperature analysis and compensation of MEMS gyroscopes

RESEARCH ON AIRBORNE INTELLIGENT HYDRAULIC PUMP SYSTEM

MODELING AND EXPERIMENTAL STUDY ON DRILLING RIG ANTI-JAMMING VALVE WITH BP NEURAL NETWORK

Research on Control Mechanism Model of Grate Cooler Based on Seepage Heat Transfer Theory

DESIGN AND PERFORMANCE OF THE CONVERGING-DIVERGING VORTEX FLOWMETER

Numerical investigation of solid-liquid two phase flow in a non-clogging centrifugal pump at offdesign

Influence of electromagnetic stiffness on coupled micro vibrations generated by solar array drive assembly

Strength Study of Spiral Flexure Spring of Stirling Cryocooler

Open Access Permanent Magnet Synchronous Motor Vector Control Based on Weighted Integral Gain of Sliding Mode Variable Structure

Automatic Drawing of the Complicated Geological Faults

Research on the synchronous vibration of the non-integral. mechanism under the vibration environment

Research and Application of Sun Shadow Location Technology in Video Big Data

Journal of NUCLEAR SCIENCE and TECHNOLOGY, Vol. 41, No. 7, p (July 2004)

Oscillating Flow Characteristics of a Regenerator under Low Temperature Conditions

FLOW AND HEAT TRANSFER PERFORMANCE OF PLATE PHASE CHANGE ENERGY STORAGE HEAT EXCHANGER. Ji-Min ZHANG, Shi-Ting RUAN, Jian-Guang CAO*, Tao XU

Intelligent Control of a SPM System Design with Parameter Variations

Humanoid Based Intelligence Control Strategy of Plastic Cement Die Press Work-Piece Forming Process for Polymer Plastics

Research of Micro-Rectangular-Channel Flow Based on Lattice Boltzmann Method

Experimental Investigation on the Acoustic Scattering Matrix for a Centrifugal Pump

Received 21 April 2008; accepted 6 January 2009

Journal of System Design and Dynamics

Contact Force-Controlled SPM System Design with Fuzzy Controller

Study on the mechanism and application of surface eddy current damper. Chen Haiyan

Simulation Analysis of Microchannel Deformation during LTCC Warm Water Isostatic Pressing Process Lang Ping, Zhaohua Wu*

Study on Erosion Mechanism of Magnetic-field-assisted Micro-EDM

NUMERICAL APPROACH TO INTER-FIBER FLOW IN NON-WOVENS WITH SUPER ABSORBENT FIBERS

Heat Transfer Experiment and Simulation of the Verification Facility for High Power Rotating Tritium Target System

A Comparative Study of Low-Specific Speed Centrifugal Pump Design Methods

A system is defined as a combination of components (elements) that act together to perform a certain objective. System dynamics deal with:

Optimization of flue gas turbulent heat transfer with condensation in a tube

Research Article Stabilization Analysis and Synthesis of Discrete-Time Descriptor Markov Jump Systems with Partially Unknown Transition Probabilities

ANALYSIS OF TURBULENT FLOW IN THE IMPELLER OF A CHEMICAL PUMP

PSD Analysis and Optimization of 2500hp Shale Gas Fracturing Truck Chassis Frame

Lattice Boltzmann Simulation of One Particle Migrating in a Pulsating Flow in Microvessel

Analysis and Calculation of Double Circular Arc Gear Meshing Impact Model

Design of Standing Wave Type Thermoacoustic Prime Mover for 300 Hz Operating Frequency

Study of Compound Heat Transfer Enhancement of Horizontal Liquid-Solid Fluidized Bed Heat Exchanger with a Kenics Static Mixer

Stability Analysis and Research of Permanent Magnet Synchronous Linear Motor

Journal of Mechatronics, Electrical Power, and Vehicular Technology

SOFTWARE ARCHITECTURE DESIGN OF GIS WEB SERVICE AGGREGATION BASED ON SERVICE GROUP

Study on High-Temperature Glass Lens Molding Process Using FEM Simulation

Numerical Simulation and Experimental Analysis of an Oxygen-Enriched Combustion Fiberglass Furnace

Research Article Stability Analysis of Journal Bearing: Dynamic Characteristics

ELG4112. Electromechanical Systems and Mechatronics

Research on One-Piece Structure Target Flow Sensing Technology Based on Fiber Bragg Grating

Curriculum Vitae. Education Background

Fuzzy PID Control System In Industrial Environment

Temperature Field Analysis of Magnetorheological Fluid. Dynamometer

A Piezoelectric Screw Dislocation Interacting with an Elliptical Piezoelectric Inhomogeneity Containing a Confocal Elliptical Rigid Core

Research on the winding control system in winding vacuum coater

Research Article Experimental Investigation on Creep Deformation Behavior of Medium-strength Marble Rock

Optimization of the nozzles structure in gas well

Department of Engineering and System Science, National Tsing Hua University,

Performance Assessment of PV/T Air Collector by Using CFD

arxiv: v1 [astro-ph.im] 19 Oct 2015

TE 75R RESEARCH RUBBER FRICTION TEST MACHINE

An Innovative Planetary Gear Reducer with Overcoming the Dead Point

B1-1. Closed-loop control. Chapter 1. Fundamentals of closed-loop control technology. Festo Didactic Process Control System

A Hybrid Approach For Air Conditioning Control System With Fuzzy Logic Controller

CHAPTER 7 NUMERICAL MODELLING OF A SPIRAL HEAT EXCHANGER USING CFD TECHNIQUE

Research on State-of-Charge (SOC) estimation using current integration based on temperature compensation

PTB S 16.5 MN HYDRAULIC AMPLIFICATION MACHINE AFTER MODERNIZATION

The first man-loading high temperature superconducting Maglev test vehicle in the world

Design and Application of a Rock Breaking Experimental Device With Rotary Percussion

93. Study on the vibration characteristics of structural of hydrocyclone based on fluid structure interaction

AN ANALYTICAL THERMAL MODEL FOR THREE-DIMENSIONAL INTEGRATED CIRCUITS WITH INTEGRATED MICRO-CHANNEL COOLING

Investigations on Performance of an Auto-Cascade Absorption Refrigeration System Operating with Mixed Refrigerants

RESEARCH ON AEROCRAFT ATTITUDE TESTING TECHNOLOGY BASED ON THE BP ANN

A Research on High-Precision Strain Measurement Based on FBG with Temperature Compensation Zi Wang a, Xiang Zhang b, Yuegang Tan c, Tianliang Li d

Numerical Simulation of Downhole Completion Equipment via Computational Fluid Dynamics

Design of RF Heat Therapy System Based on DS18B20 and FPGA

Minhhung Doan, Thanhtrung Dang

Numerical Simulation Analysis of Ultrafine Powder Centrifugal Classifier Bizhong XIA 1, a, Yiwei CHEN 1, b, Bo CHEN 2

1439. Numerical simulation of the magnetic field and electromagnetic vibration analysis of the AC permanent-magnet synchronous motor

Numerical investigation of a looped-tube traveling-wave thermoacoustic generator with a bypass pipe

FLOW DIVIDERS "XV 3 serie" ENGLISH VERS:

The basic principle to be used in mechanical systems to derive a mathematical model is Newton s law,

1373. Structural synthesis for broken strands repair operation metamorphic mechanism of EHV transmission lines

Hot & Cold. Schaeffler s Thermal Management for a CO. Reduction of up to 4 %

Air Cooler Industry AC-LN 1-7 / ACA-LN 2-7 / ACAF-LN 2-7

Simulation of a Downsized FDM Nozzle

NUMERICAL SIMULATION OF CONJUGATE HEAT TRANSFER FROM MULTIPLE ELECTRONIC MODULE PACKAGES COOLED BY AIR

Influence of Chord Lengths of Splitter Blades on Performance of Small Axial Flow Fan

Defect Location Analysis of Tank Bottom Based on Acoustic Emission with Different Location Algorithms

Coupling Physics. Tomasz Stelmach Senior Application Engineer

ScienceDirect. Experimental Validation on Lift Increment of a Flapping Rotary Wing with Boring-hole Design

LEAKLESS COOLING SYSTEM V.2 PRESSURE DROP CALCULATIONS AND ASSUMPTIONS

D O T 1 ; O T 2 ; O T 3 ; O T i

Nondestructive Testing and Performance Prediction of Soybean Stalk Board

Robust Speed Controller Design for Permanent Magnet Synchronous Motor Drives Based on Sliding Mode Control

Effect of roughness shape on heat transfer and flow friction characteristics of solar air heater with roughened absorber plate

Experimental Study of Convective Heat Transfer and Thermal Performance in the Heat-Sink Channel with Various Geometrical Configurations Fins

MODELLING OF SINGLE-PHASE FLOW IN THE STATOR CHANNELS OF SUBMERSIBLE AERATOR

Transcription:

Research Journal of Applied Sciences, Engineering and Technology 7(5): 937-943, 014 DOI:10.1906/rjaset.7.338 ISSN: 040-7459; e-issn: 040-7467 014 Maxwell Scientific Publication Corp. Submitted: January 9, 013 Accepted: February 5, 013 Published: February 05, 014 Research Article Design and Research of a New Thermostatic Valve 1 Chen Hai-Chu, 1 Wu Fang-Yi, Zhu Yin-Fa and 1 Xiong Gen-Liang 1 School of Mechanical and Electrical Engineering, Nanchang University, Nanchang, Jiangxi 330031, China Institue of Technology of Lishui University, Lishui 33000, China Abstract: This study designed a new type of intelligent thermostatic mixing valve which could keep the temperature and flux of the outlet water constant by the adaptive controller. It firstly established mathematical model of the valve about angle-flux and angle-temperature and then it applied the Fluent software to numerical simulation of the valve about flow field based on the two-equation turbulence model. Finally, it designed the intelligent controller hardware and developed the controlling software of the valve. With the controller and it finished experiments with the thermostatic valve prototype. The results of simulation and experiments prove that the correctness of the theoretical research and they can be used to improve designing of the thermostatic valve. Keywords: CFD, intelligent control, modeling, simulation, thermostatic valve INTRODUCTION Thermostatic mixing valve is designed for supporting products of the hot water system, which are widely used in electric water heater, solar water heater and geothermal heating water system. Thermostatic valves, such as manual adjustable mixing valve and mechanical thermostatic valve with thermal sensor (Luo et al., 008; Cai and Yu, 009) have defects in controlling precise and response speed and need to be improved greatly. Manual adjustable mixing valve is difficult to control and keep the temperature and flux constant of the outlet water, which greatly causes waste of the water and electricity. The thermostatic valve with thermal sensor is a kind of mechanical thermostatic valve in essence; the thermal sensor can be divided into two kinds: memory of titanium alloy and thermal paraffin. The control accuracy and response speed of this kind thermostatic valve depends on expansion performance of the thermal sensor. The references (Wu et al., 004; Matsui et al., 1995; Ohkata and Tamur, 1997) have studied for expansion properties of the memory of titanium alloy and proved the driving characteristics of the memory of titanium alloy is difficult to realize micro adjusting displacement and output big driving force of the thermostatic valve. The references (Li et al., 006; He et al., 008; Wang et al., 003) have studied for expansion properties of the thermal paraffin and the results prove the thermal expansion interval of the thermal paraffin will become larger with the melting process change, so the flux is difficult to keep constant. In this study, it designed an intelligent thermostatic mixing valve based on the fuzzy control and STC of the single chip microcomputer. Users can adjust the temperature of the outlet warm water according to their need and the controller can make the temperature quickly achieve the preset value and keep stably, which ensures the temperature of the outlet warm water constantly and it is not affected by the temperature, pressure and flux. In this study, it firstly establishes the mathematical model of the thermostatic valve and then comprehensive analysis on the characteristics of the thermostatic valve by the numerical simulation and experimental research. MATHEMATICAL MODEL OF THE THERMOSTATIC VALVE Structure and working principle of the thermostatic valve: The structure of the thermostatic valve is shown in Fig. 1. The study principle of the valve is: when the Fig. 1: The structure of the thermostatic valve 1 cool water inlet; warm water outlet; 3 hot water inlet; 4 stepping motor; 5 temperature sensor; 6 valve body Corresponding Author: Wu Fang-yi School of Mechanical and Electrical Engineering, Nanchang University, Nanchang, 330031, China, Tel.: +86-18070510611 This work is licensed under a Creative Commons Attribution 4.0 International License (URL: http://creativecommons.org/licenses/by/4.0/). 937

π 4 ( ) A= D D L tan γ cos γ (3) Fig. : Structure diagram of the ventileinheit temperature of the outlet warm water is higher or lower, the temperature sensor can real-time monitor it and give feedback the measured temperature signal of the outlet warm water to the valve controller. According to the signal, the controller will generate controlling signal to drive the stepping motor to rotate and then drive the ventileinheit to move through the screw structure, which can change the axis rotate angle of the stepping motor to the linear displacement of the ventileinheit. When users need to change the flux of the outlet warm water, stepping motor will drive the ventileinheit to open (increasing water flux) or close (decreasing flux), thus realize the flux adjustment of the outlet warm water. Flow models: The ventileinheit of the thermostatic valve is designed for cone (Fig. ), which is connected with the stepping motor by a screw structure. When the liquid flow through the ventileinheit, the change of the through-flow sectional area will cause the change of the outlet warm water flux and the flux of the valve can be calculated as: D = Outlet diameter of the valve γ = The cone ventileinheit angle of the valve According to the flow continuous equation and the conservation of mass, the flux of the outlet warm water can be calculated as: Q = Q + Q m m 1 m π ltanγ ltanγ α cosγ ρ D D θ1 p1 + D D θ p 4 π π = = The flux of inlet hot water = The flux of inlet cool water p 1 = The differential pressure of inlet hot water p = The differential pressure of inlet cool water (4) From Eq. (4), it is known that the flux of the outlet warm water is not only related with the pressure differential p, but also with the stepping motor angle θ. Therefore, even if the inlet water pressure of the valve is unstable which leads to change of the differential pressure, it can also ensure the flux of the outlet warm water constantly through controlling the rotate angle of the stepping motor. Q = α A ρ p (1) m Q m = The flux of the outlet water α = The flux coefficient A = Area of the valve port p = The differential pressure of inlet and outlet of the valve ρ = Density of the water Through the screw driving, the rotation angle θ of the stepping motor can be transformed to the linear displacement L of the ventileinheit, which can be calculated as: π l θ = L () l = The pitch of the screw θ = Rotate angle of the stepping motor L = Displacement of the ventileinheit According to Fig., the through-flow sectional area can be calculated as (Chen et al., 008): 938 Temperature model: According to the energy conservation law, it is known that the release heat of hot water is equal to the absorbed heat of cool water in the blending process. And because of the quality is equal to the mass flux Q m multiplies by time t, therefore, when the ventileinheit of the hot and cool water open at the same time, the heat balance equation can be expressed as: ( ) ( ) c Q t T T = c Q t T T (5) m1 1 m c = The specific heat capacity T = Absolute temperature of the outlet warm water T 1 = Absolute temperature of the inlet hot water T = Absolute temperature of the inlet hot water According to Eq. (), (3) and (5), the absolute temperature T of the outlet warm water can be calculated as: l tan γ l tan γ D D θ1 p1 T1 + D D θ p T π π T = π π l tan γ l tan γ D D θ1 p1 + D D θ p (6)

Table 1: Results of the numerical simulation Serial number Absolute temperature of inlet hot water T1/K Absolute temperature of inlet cool water T/K Hydraulic diameter of inlet hot water D1/mm Hydraulic diameter of inlet cool water D/mm Absolute temperature of outlet warm water T/K Iterations times 1 30 95 10 4 600 31.7 1.09 30 300 9 5 870 313.1 1.01 3 35 95 8 6 950 31.9 0.97 4 350 300 6 8 900 313.0 0.91 5 360 305 5 9 880 313.3 1.01 6 370 310 4 10 600 31.7 1.09 Flow of warm water outlet Qm/Kg/s According to Eq. (6), it is known that the temperature of the outlet warm water is not only related with the hot and inlet cool water temperature, but also related with the differential pressure ρ and the stepping motor angle θ. Therefore, even if the inlet hot water temperature decreases in the water heater with using, the valve controller can adjust the angle θ of the stepping motor to ensure the temperature of the outlet warm water constant. NUMERICAL SIMULATION AND ANALYSIS Fig. 3: Simplified model of the valve In order to validate the correctness of the theoretical temperature model, analyze the relationships between the pressure, temperature, flux of the inlet cool and hot water with the outlet warm water, it applies the Fluent software to numerical simulation about the flow field of the thermostatic valve. In order to reduce the simulation calculation and maintain the flow field really, it adopts the reasonable simplified treatment to the physical model according to the structure of the valve. The simplified model is similar to the tee (Fig. 3). Where it chooses boundary conditions as and then begins to simulate. From the simulating data shown as Table 1, it can easily find out that even if the different temperature conditions of the inlet hot and cool water, the corresponding hydraulic diameter (area) of the inlet hot and cool water can keep the temperature and flux constantly of the outlet warm water. Figure 4 is the curve of the outlet warm water about area-weighted average static temperature. Figure 5 is the flux distribution nephogram of z = 0 section and the simulating parameters are T 1 = 360K, T = 305K, D 1 = 5, D = 9. According to the Table 1, it is known that it will have the corresponding hot and inlet cool water diameter to keep the temperature of the outlet in approximately 313.0 K (40ºC for the human body the most comfortable shower temperature) and keep the flux in approximately 1.01 kg/s (6 L/min) under the different hot and inlet cool water temperature. In the error allow range, it can explain that the temperature and flux of the outlet warm water is constant. At the same time, it can demonstrate the validity of the theoretical analysis that the actual value of the outlet warm water temperature and flux can be consistent with the set value through the thermostatic valve and 939 Fig. 4: Curve of the outlet warm water about area-weighted average static temperature controller adaptive adjust under the different hot and inlet cool water temperature. In order to validate the correctness of the mathematical model about the thermostatic valve, it compares the simulation values with the calculated values. According to Eq. (1) and Eq. (1), take as α = 0.8, ρ =1 10 3 kg/m 3 and the differential pressure p about water flowing through the ventileinheit, it can easily calculate out the flux and temperature of the outlet warm water of the valve. Figure 6 is the contrast curve of the simulation value and the calculated value about the flux of the outlet warm water. Figure 7 is the contrast curve of the simulation value and the calculated value about the temperature of the outlet warm water. According to Fig. 6 and 7, the variation tendency of the CFD simulation results and the calculated value is consistently, which proves that the mathematical model of the thermostatic valve is correct. DESIGN INTELLIGENT CONTROLLER OF THE VALVE The controller uses STC90C5RC as the controlling core chip and the hardware system mainly constitutes with five parts: temperature acquisition circuit module, preset circuit module, power supply

(a) (b) (c) Fig. 5: Flow distribution nephogram of the z = 0 section; (a) Pressure distribution nephogram of z = 0 section; (b) Temperature distribution nephogram of z = 0 section; (c) Velocity distribution nephogram of z = 0 section Fig. 6: Contrast curve of the flux Fig. 7: Contrast curve of the temperature module, display module and control circuit module. The controller principle diagram is shown as Fig. 8. Design intelligent controller hardware: The temperature sensor is installed in the outlet of the valve 940 to measure the temperature of the warm water and is isolated by a rubber ring. Temperature acquisition module is achieved by DS18B0, which has characteristics of high performance, low power consumption and strong anti-jamming. The temperature

with ULN003 chips. The controller circuit diagram is shown as Fig. 9. Fig. 8: Controller principle diagram measure range of the sensor is from -55 C and 5ºC and the accuracy is 0.0675 C, which can completely satisfy the valve working temperature range from 5 Cto 75 C. The keyboard has five independent keys. The keys are respectively defined as "start", "close", "flux gear", "temperature increase", "temperature decrease". According to the most appropriate temperature, the controlling system sets the default temperature as 40ºC. If the shower wants to change the temperature, he/she can operate the corresponding key on the operation panel board. The stepping motor can change the electrical pulses signal into angular displacement. It uses two stepping motors of four phase eight pats to drive the ventileinheit of the valve. When the driver receives pulse signals from the MCU, it will drive the stepping motor to rotate according to the step angle. When the stepping motor receives a series of continuous control pulse signal, it can rotate continuously. Because the output signal of the MCU is not big enough, an amplifier is designed Design intelligent controller software: The controller uses STC90C5RC as the controlling core chip and it uses the fuzzy control algorithm to realize intelligent control. The control system flow diagram is shown as Fig. 10. From the Fig. 10, the controller firstly finishes initialization according to the keyboard input value and then it will operate with the set value according to intelligent controller program until the temperature and flux of the outlet warm water are constant. The fuzzy control algorithm: In the process of the software design, this study uses the modular programming based on the fuzzy control algorithm. As the temperature of the outlet warm water exist pure lag, result in imprecise measure. It is very difficult to establish the valve accurate mathematical model to realize the control of the temperature. Therefore, this design uses the fuzzy control algorithm to realize constant temperature control. In the set of temperature and flux, the input of the fuzzy controller is the deviation E of the measure temperature and the set temperature (E = t 0 - t, where t 0 is the set temperature, t is the measured temperature) and the change of deviation ( E = t i t i-1,where t i-1 is the i-1 time measured temperature, t i is the i time measured temperature), the output is the rotation angle and direction of the stepping motor. E is divided into six fuzzy subset PB (positive broad), PM (positive median), PS (positive small), NS (negative small), NM Fig. 9: Controller circuit diagram 941

direction and the size of the rotation angle, the stepping motor which cool and hot water ventileinheit correspond can be divided into PB, PM, PS, Z, NS, NM, NS. The fuzzy control rules are shown as Table. EXPERIMENTS AND ANALYSIS Fig. 10: Control system flow diagram After the structure design, intelligent control system design and simulation analysis of the thermostatic valve are completed, this study manufacture the thermostatic valve prototype (Fig. 11) for test the actual control effect. The test purpose is: it makes that the outlet temperature and flux of the actual value and the set value are consistent through the thermostatic valve and controller adaptive adjusts in the different inlet hot and cool water temperature; it tests the correctness of the program controller and the speed of response at the same time. The test results are shown as Table 3. According to the experimental data with different inlet hot and cool water temperature, it verifies the consistency of the design, simulation and experimental results. And the response time can keep in 7 seconds or so, it verifies the temperature of the inlet hot water almost no influence to the ability of the thermostatic valve respond. CONCLUSION Fig. 11: Thermostatic valve physical prototype diagram Table : The fuzzy control rules E/ E P Z N PB NB NB NB PM NM NM NS PS NS NS Z NS Z PS PS NM PS PM PM NB PB PB PB Table 3: The experimental results Serial number Temperature of inlet hot water T 1/ C Temperature of inlet cool water T / C Response time t/s 1 50 10 7.85 40 55 10 7.78 40 3 60 10 7.0 40 4 65 10 6.98 40 5 70 10 7.08 40 6 75 10 7.14 40 7 80 10 7.35 40 8 85 10 7.55 40 9 90 10 7.68 40 Temperature of hot water outlet T/ C (negative median) and NB (negative broad), the corresponding temperature deviation is: PB>TM1 C, TM C < PM < TM1 C, 0 C < PS < TM C, TM3 C < NS < 0 C, TM4 C < NM < TM3 C, NB < TM4 C (TM4 < TM3 < 0 < TM<TM1). E is divided into three fuzzy subset P (positive), Z (zero), N (negative), the corresponding deviation change: t i t i-1 > A 0, -A 0 < t i t i-1 < A 0, t i t i-1 > A 0, (A 0 > 0). According to the It introduces the structure and working principle about a kind of new intelligent thermostatic mixing valve and it established mathematical model about angle-flux and angle-temperature of the valve. According to the numerical simulation results about the valve flow field, it proves that the temperature and flux of the outlet warm water can keep constantly with the valve, which demonstrates the validity of the theoretical analysis. According to the experimental data with different inlet hot and cool water temperature, it verifies the consistency of the design, simulation and experimental results. And the response speed of the temperature sensor is very quickly and the outlet temperature can keep coincidence with shower setup. ACKNOWLEDGMENT This study is funded by the Natural Science Foundation of China (NSFC, No.: 5165034, No.: 6163045), the Natural Science Foundation of Zhejiang Province (No.: LY1E05011). REFERENCES Cai, C.G. and T.J. Yu, 009. Development and utilization of thermostatic valve for SWH. Solar Energ., 43(1): 36-37. 94

Chen, H.C., X.Y. Wang, R.H. Zhang, et al., 008. Design and modeling of precise flux valve driven by piezoelectric ceramics. J. Zhejiang Univ. Eng. Edn., 4(11): 1936-1939. He, S.Q., X. Liu, X.Y. An, et al., 008. Study on law of preparing paraffin used in thermostatic valve based on DTA analysis. Fluid Mach., 36(10): 8-10. Li, S.X., Q.H. Ba, Y. Sui, et al., 006. Test and research on the wax-formula thermostatic valve in cooling system of locomotive engine. Fluid Mach., 34(9): 4-7. Luo L.S., C.Y. Wang, H. Yuan, et al., 008. A New kind of three-way thermostatic valve. Chinese Hydraul. Pneumatics, 3: 78-80. Matsui, H., M. Enoki, T. Kato, et al., 1995. Application of shape memory alloy to thermostatic mixing valve. J. Phys., 4(58part): 153-158. Ohkata, I. and H. Tamur, 1997. R-phase transformation in the Ti-Ni shape memory alloy and its application. Proceeding of the Materials Research Society Symposium, 459: 345-355. Wang, G.Z., L.H. Ji, S.Z. Wen, et al., 003. Thermal expansion formula micro-actuator actuated by induction heating. Chinese J. Mech. Eng., 39(): 79-83. Wu, H.C., et al., 004. Development performance analysis and test of the thermo valve in energysaving cooling system. Chin. Hydraul. Pneumatics, 11: 19-1. 943