Development of a small-scale reverberation room

Similar documents
MEASUREMENTS OF SOUND ABSORPTION TIMBERCRETE

Consultancy Report Ref: 9383-R01

REPORT ON THE DETERMINATION OF SOUND ABSORPTION COEFFICIENTS OF WOVEN IMAGE ECHO PANEL 7MM TESTED WITH A 20MM AIR GAP IN A REVERBERATION ROOM.

REPORT ON THE DETERMINATION OF SOUND ABSORPTION COEFFICIENTS OF WOVEN IMAGE ECHO PANEL 24MM TESTED WITH NO AIR GAP MEASURED IN A REVERBERATION ROOM.

Testing Procedure: AS ISO

LABORATORY MEASUREMENTS OF THE SOUND ABSORPTION OF CLASSICTONE 700 ASTM C Type E Mounting. Test Number 2

Measurement of Acoustic Properties of light weight concrete SL-Deck

DELTA Test Report. DANAK TEST Reg. no Measurement of Sound Absorption Coefficient for Kvadrat Soft Cells Wall Panel Type Time

Test Report. RI Acoustic Lab. Measurement of Sound Absorption Coefficient for RockDelta NoiStop Noise Barrier. 20 Feb. 07

LABORATORY MEASUREMENTS OF THE SOUND ABSORPTION COEFFICIENTS OF OSCAR EVO-PANELS

A L I O N Technical Center. Test Report

RIVERBANK ACOUSTICAL LABORATORIES

Users Manual. Marshall Day Acoustics. Double Panels Contact 33 Details Marshall Day 37.8 Acoustics PO Box

Technical Report. Project. The Laboratory Determination of The Random Incidence sound Absorption Coefficient of VertiQ Panels.

DELTA Test Report. Measurement of sound absorption coefficient for 15 mm Fraster felt Plus acoustic panels with mounting depth 45 mm

A L I O N Technical Center. Test Report. Port Coquitlam, British Columbia, Canada

TFI Report Sound Absorption Impact Sound Insulation

Using an ambisonic microphone for measurement of the diffuse state in a reverberant room

LABORATORY MEASUREMENT OF SOUND ABSORPTION OF SONOGLASS SPRAY-ON TREATMENT IN THREE CONFIGURATIONS

DELTA Test Report. Measurement of Sound Absorption for AqFlex ON, one Sample as a discrete Object. Performed for Flex Acoustics

TFI Report Sound Absorption Impact Sound Insulation

RIVERBANK ACOUSTICAL LABORATORIES

TFI Report Sound Absorption Impact Sound Insulation

Evaluation of standards for transmission loss tests

Benefits of Reduced-size Reverberation Room Testing

ISO 354 INTERNATIONAL STANDARD. Acoustics Measurement of sound absorption in a reverberation room

Calcul des coefficients d'absorption alpha sabine

Answer - SAQ 1. The intensity, I, is given by: Back

THE ACOUSTIC IMPEDANCE MEASUREMNET SYSTEM USING TWO MICROPHONES

Renolit stretch ceilings

Laboratory for Acoustics. Determination of the sound absorption (reverberation room method) of Airpanel, manufacturer Texdecor

Measurement of sound absorption coefficient for Fraster felt SpaceCover

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6266/ARL-SA6274 Revision 0 ARL

ROLLEASE ACMEDA ACOUSTICAL PERFORMANCE TEST REPORT

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6956 Revision 1 ARL

Micro-perforated sound absorbers in stretched materials

Fabric Dazzle 6086 Manufacturer Carnegie Fabrics

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6712/ARL-SA6713 Revision 0 ARL

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6986/ARL-SA6987 Revision 0 ARL

Curtain fabric type Ace Manufacturer Kvadrat A/S

An examination of some aspects of the use of ISO 140 Part 4 and 7 in field measurements.

Acoustic response in non-diffuse rooms

Paseo Recoletos, nº Madrid TEST REPORT

Page 1 of 10 pages Appendix, 5 pages Report no.: P Glostrup, October 12th 2012 Project: Claimant:

Laboratory for Acoustics

Acoustic design of lightweight cabin walls for cruise ships

Laboratory for Acoustics

stylegreen Iceland Moss / Reindeer Moss of the company FlowerArt

Laboratory for Acoustics. Determination of the sound absorption (reverberation room method) of curtains, manufacturer Vescom BV

REPORT N CR

TFI Report Sound Absorption Impact Sound Insulation

1238. Relation between reduction of weighted impact sound pressure level and shape of small size specimen of floating floor construction

Some issues in measurement of the random-incidence scattering coefficients in a reverberation room

Fabric REFLECTACOUSTIC

Investigations on real-scale experiments for the measurement of the ISO scattering coefficient in the reverberation room

Fabric Sport. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M102794/02

Notes on Absorption and Impedance Measurements

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

INVESTIGATIONS INTO THE PERFORMANCE OF THE REVERBERATION CHAMBER OF THE INTEGRATED ACOUSTICS LABORATORY. A Thesis Presented to The Academic Faculty

Fabric UDINE. Measurement of sound absorption according to EN ISO 354. Test Report No. M102794/32

Fabric ALEX. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M102794/09

Fabric TWIST MELANGE Manufacturer Gabriel A/S

Roller blind fabric PRIMACOUSTIC R

Fabric Medley Manufacturer Gabriel A/S

Yalıtım Kontrol Koruma. Insulation Control Protection

Fabric VELOS STRATO. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M102794/10

FIFTH INTERNATIONAL CONGRESS ON SOUND AND VIBRATION DECEMBER 15-18, 1997 ADELAIDE, SOUTH AUSTRALIA

Report. Laboratory for Acoustics

The Negative Coefficient of Bruel & Kjaer Green Paint

Engineering Noise Control

ACOUSTIC TESTS ON ORIGINAL CONCRETE AND INERT MIXTURE MATERIALS

The diagram below. to the by the. outlet into. calculation. Since TRANSMISSION VIA STRUCTURE. Vibration Via Supports Duct Breakout

Fabric Corsica. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M111250/16

Laboratory for Acoustics. Determination of the sound insulation of sliding door constructions, manufactured by Metaflex

ACOUSTICS 1.01 Pantone 144 U & Pantone 5405 U

ISO INTERNATIONAL STANDARD

Report. P.O. Box 70 NL 5700 AB Deurne The Netherlands Report number: A E-RA Date: 12 februari 2014 TS/TS/JW/A E-RA

Fabric Zetacoustic. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M102794/07

Radiated sound power estimates of building elements by means of laser Doppler vibrometry

LABORATORY MEASUREMENTS OF THE REDUCTION OF TRANSMITTED IMPACT NOISE PANETTI OVERLAID BY CONCRETE FLOORING

Fabric XPRESS + PU-foam Manufacturer Gabriel A/S

Determination of sound absorption coefficient in impedance tubes according to ISO (2 appendices)

Fabric STREAMER pro. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M111250/04

Part 2: Methods for special reverberation test rooms

Fabric Umbria III R. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M102794/13

Available online at ScienceDirect. Energy Procedia 78 (2015 ) th International Building Physics Conference, IBPC 2015

REPORT. Client. Test object. Date of testt. Results. Rönnåsgatan 5B Ulricehamn. (7 appendices) content of the

EXPERIMENTAL VERIFICATION OF THE EUROPEAN METHODOLOGY FOR TESTING NOISE BARRIERS IN SITU: SOUND REFLECTION

SOUND ABSORPTION OF SLAT STRUCTURES FOR PRACTICAL APPLICATIONS

Witold MIKULSKI. Central Institute for Labour Protection National Research Institute Czerniakowska 16, Warszawa, Poland;

ISO INTERNATIONAL STANDARD

Holistic Acoustic Absorber Design: from modelling and simulation to laboratory testing and practical realization. Toulson, R. and Cirstea, S.

unit 4 acoustics & ultrasonics

Technical Brief 003 Report on the Measurement of Sound Absorption of Planex Linea Storage Units

The effect of an edge on the measured scattering coefficients in a reverberation chamber based on ISO

campus, Kuching, Malaysia Kuching, Malaysia

Comparison of Noise Test Codes when Applied to air Compressors

A STUDY ON SOUND ABSORBING PROPERTIES OF BIO-DEGRADABLE ACOUSTIC MATERIAL

9. TRANSMISSION OF SOUND THROUGH STRUCTURES

Report. Laboratory for Acoustics

Transcription:

Proceedings of ACOUSTICS 2016 9-11 November 2016, Brisbane, Australia Development of a small-scale reverberation room Alexander Rasa Noise Control Research & Development, Pyrotek Pty Ltd, Sydney, Australia ABSTRACT A reverberation room was desired on-site in order to measure the absorption coefficients of materials during the research and development process without utilising external laboratories. Making use of the available resources, a regular office was converted into a small-scale reverberation room. Whilst an ideal reverberation room has a volume of at least 200 m 3, this reverberation room was designed around the limited 48 m 3 room volume. Significant construction work was conducted to convert the room, including the implementation of diffusion panels. Verification of the room was carried out by testing in conformance with ISO 354:2003 (with deviation to account for the room volume) using Reapor, which has been tested in four different full-scale reverberation rooms to the same ISO 354:2003 standard, allowing comparisons to be drawn. Testing revealed satisfactory correlation between the small-scale and full-scale reverberation rooms. A small-scale reverberation room was successfully developed, saving time and resources by enabling us to test the sound absorption coefficients of materials during the research and development process, before sending the final material to an independent acoustical laboratory for accredited ISO 354:2003 results. 1. INTRODUCTION Reverberation rooms can be used for a variety of acoustical testing, such as measuring the sound power of a source, the transmission loss of a structure, calibration of transducers, or the focus of this reverberation room: the sound absorption of a material. By definition, a reverberation room has a uniform distribution of sound energy, known as a diffuse sound field, where sound intensity is independent of location. A diffuse sound field means that sound energy can interact with a sample at all angles of incidence, which is effectively random incidence. An ideal reverberation room achieves this with non-parallel high density reflective surfaces, large room volumes of at least 200 m 3, omnidirectional sound sources and diffusive elements which may be stationary or moving. The purpose of the test method is to measure the sound absorption of materials, evaluating how efficient a material is at absorbing sound energy. As the sound absorbing characteristics of a material is dependent on the angle of incidence, the diffuse sound field within the reverberation room allows measurement of the average sound absorption coefficients over all angles of incidences. This is in contrast to impedance tube testing, where the angle of incidence (0 ) is singular (ASTM International, 2012). Whilst there are applications where normal incidence absorption coefficients are useful, random incidence absorption coefficients are typically more relevant. This paper aims to explore the development of a reverberation room used for measuring sound absorption coefficients with a volume of 48 m 3, which is only 24% of the recommended 200 m 3 room volume specified in the ISO 354:2003 (International Organization for Standardization, 2003) and ASTM C423-09a (ASTM International, 2009) standards. The purpose of the room is to evaluate the sound absorption of materials during the research and development process without using an external independent laboratory, saving both time and cost. 2. CONSTRUCTION The opportunity for a reverberation room conversion was conceived when an office adjacent to the research & development laboratory became vacant. It was rectangular shaped, 4.8 m long, 3.6 m wide and 2.8 m high, resulting in a room volume of 48 m 3. The floor consisted of a standard 150 mm thick steel-reinforced concrete slab with carpet glued onto it. The walls were single brick with penetrations for two windows and an air-conditioning unit. The ceiling was constructed using standard 10 mm thick plasterboard, with approximately 500 mm of space above between the ceiling and roof. A single light-weight hollow-core door with no seals was the only entrance/exit. A brief analysis of the original room revealed a low reverberation time primarily caused by the lightweight construction of the ceiling and the absorptive carpeted floor. Furthermore, the poor transmission loss of the ceiling and door allowed outside noise events to interfere. Although the regular shape of the room and the limited 48 m 3 volume were noted issues, it was not possible to improve either issue without significant time or cost. ACOUSTICS 2016 Page 1 of 10

9-11 November 2016, Brisbane, Australia Proceedings of ACOUSTICS 2016 2.1 Ceiling The ceiling was torn down and extensive upgrades were carried out to reinforce the ceiling timber structure in order to support the increased load. To replace the standard 10 mm plasterboard, three layers of 9 mm thick compressed fibre cement sheets were mounted in an overlapping fashion. The top layer was coated with a thick layer of damping compound. Lighting was not reinstated on the ceiling. Photograph 1 and 2: Construction of the reverberation room ceiling 2.2 Doors and Floor The single light-weight hollow-core door was replaced with two sealed hardwood solid-core doors. The carpet and adhesive were removed to reveal the bare concrete slab. 2.3 Walls The air-conditioning unit and both windows were removed, and the remaining cavities were filled with bricks. Two PVC pipes, which were for ventilation to the spaces below the reverberation room, were wrapped with Soundlag 4525C and boxed with 9 mm thick compressed fibre cement sheeting. All electrical (except for one) and data points were removed from the walls, and any remaining gaps were sealed with the exception of a single penetration for microphone and speaker cabling. A single small LED floodlight was installed on the wall to provide lighting, with the switch located outside the room. Finally, the walls were painted to seal the surface. 2.4 Diffusion Stationary diffusion panels of various sizes were hung from the ceiling at a variety of heights and angles, distributed evenly throughout the reverberation room. The Soundalloy MPM 2100 panels are constructed using two layers of aluminum bonded together with an adhesive damping layer, creating constrained-layer damped diffusion panels. In conformance with the recommendations given in the ISO 354:2003 and ASTM C423-09a standards, enough panels were hung for the area (both sides) of the diffusers to equal approximately 25% of the total surface area of the reverberation room and have a surface density greater than 5 kg/m 2. The diffusion panels were hung using snap hooks to allow for easy removal or adjustment during the diffusivity checks. Photograph 3 and 4: Before and during the installation of the stationary diffusion panels Page 2 of 10 ACOUSTICS 2016

Proceedings of ACOUSTICS 2016 9-11 November 2016, Brisbane, Australia 3. EXPLORATION OF REVERBERATION ROOM PERFORMANCE 3.1 Volume and Shape ISO 354:2003 states a minimum room volume of 150 m 3, and ASTM C423-09a states a minimum room volume of 125 m 3. Both standards recommend at least 200 m 3, with a maximum room volume of 500 m 3 specified in ISO 354:2003, further reinforcing the small-scale aspect of the 48 m 3 Pyrotek reverberation room. The room conforms to the shape condition specified within section 6.1.2 of ISO 354:2003: <1.9 (1) Where is the length of the longest straight line within the boundary of the room (6.6 m), and is the volume of the room (48 m 3 ). The room also meets the shape conditions described within section 7.3 of ASTM C423-09a, where no two room dimensions are equal and the ratio of the largest to the smallest dimension is not greater than 2:1. 3.2 Diffusivity The check of diffusivity was carried out in accordance to Annex A within ISO 354:2003. The test specimen used was 50 mm thick Reapor, which meets the criteria set by ISO 354:2003 with sound absorption coefficients greater than 0.9 over the frequency range of 500 Hz to 4 khz. After conducting the diffusivity checks, it was found that the area (both sides) of diffusers required to achieve satisfactory diffusion was approximately 18% of the surface area of the room. This falls within the 15% to 25% prediction for rectangular rooms as stated in the ISO 354:2003 and ASTM C423-09a standards. 3.3 Equivalent Empty Room Sound Absorption Area The equivalent sound absorption area of the empty room was measured and calculated, with the maximum values adjusted for the room volume, to ISO 354:2003 section 6.1.4 and 8.1.2.1. Although the equivalent sound absorption area is below the maximum across the entire measured frequency range, due to the room dimensions, the shape of the curve below 250 Hz shows dips and peaks measuring more than 15% from the mean of the values of both adjacent one-third-octave bands. This is shown in Graph 1. Equivalent Sound Absroption Area (m 2 ) 6.0 5.5 5.0 4.5 4.0 3.5 3.0 2.5 2.0 1.5 1.0 0.5 0.0 100 125 160 200 250 315 400 500 630 800 10001250160020002500315040005000 Maximum Measured Graph 1: The maximum and measured equivalent sound absorption area of the empty Pyrotek small-scale room ACOUSTICS 2016 Page 3 of 10

9-11 November 2016, Brisbane, Australia Proceedings of ACOUSTICS 2016 4. METHOD Testing was carried out in accordance with ISO 354:2003, with exception to a deviation in sample size. The sample size for testing to ISO 354:2003 with a standard 200 m 3 room is between 10 m 2 and 12 m 2. In scale with the smaller volume of the reverberation room, the sample size was 2.4 m 2. The samples were mounted using Type A mounting and the perimeter was enclosed by 12.5 mm thick wood. The test specimen used for all testing was 50 mm thick Reapor, which is a rigid homogeneous porous absorber with a density of 270 kg/m 3 manufactured from recycled glass granules. Reapor was chosen for verification testing due to the large number of sound absorption test reports available from independent acoustical laboratories. Table 1 displays the primary details of each Reapor sound absorption test, whilst tables 2-5 and graphs 2-5 show and compare results. Testing was conducted using the interrupted noise method, with pink noise emitted by a Larson Davis BAS001 omnidirectional dodecahedral sound source which was amplified by a Crown XLS1000. The microphone used was a Bruel & Kjær Type 4189, with the system running through a Bruel & Kjær PULSE analyser platform. The temperature, relative humidity and atmospheric pressure were measured with a Greisinger GFTB100. Six microphone and sound source positions were measured, with three averages per position. The empty room was tested with the perimeter-sealing wooden frame in place. The weighted sound absorption coefficient (α w ) was calculated in accordance with ISO 11654:1997 (International Organization for Standardization, 1997). The noise reduction coefficient (NRC) and the sound absorption average (SAA) were calculated in accordance with ASTM C423-09a. The 95% confidence intervals for the absorption coefficients measured within the Pyrotek small-scale reverberation room have been plotted as error bars onto graphs 2-5. 5. RESULTS Table 1: The primary specifications of the reverberation rooms and tests referred to in this paper Room Volume (m 3 ) Total Surface Area (m 2 ) Number of Diffusers Type of Diffusers Test Standard Temperature During Test ( C) Relative Humidity During Test (%) Pyrotek Small- Scale Room Laboratory 1 Laboratory 2 Laboratory 3 Laboratory 4 48 205 217 200 393 95 261 305 236 322 9 14 6 17 15 Stationary Stationary Stationary Stationary Stationary ISO 354:2003 (with deviance) AS ISO 354:2006 ISO 354:2003 AS ISO 354:2006 ISO 354:2003 29 10 17 22 24 55 79 45 53 54 Atmospheric Pressure During Test (kpa) 100.9 103.1 101.1 101.3 96 Sample Size (m 2 ) 2.4 11.7 10.9 10.5 13.7 Year of Test 2016 2015 2010 2009 2005 Location Australia Australia New Zealand Australia Germany Page 4 of 10 ACOUSTICS 2016

Proceedings of ACOUSTICS 2016 9-11 November 2016, Brisbane, Australia 5.1 Laboratory 1 Table 2: The absorption coefficients measured within the Pyrotek small-scale room and independent laboratory 1 Pyrotek Small-Scale Room Laboratory 1 Difference 100 0.04 0.08 0.04 125 0.11 0.10 0.01 160 0.22 0.29 0.07 200 0.36 0.37 0.01 250 0.57 0.57 0.00 315 0.86 0.92 0.06 400 1.10 1.12 0.02 500 1.17 1.23 0.06 630 1.16 1.21 0.05 800 1.08 1.02 0.06 1000 0.94 0.98 0.04 1250 0.93 1.03 0.10 1600 1.03 1.09 0.06 2000 1.05 1.08 0.03 2500 0.99 1.04 0.05 3150 1.01 1.05 0.04 4000 0.96 1.04 0.08 5000 0.99 1.04 0.05 NRC 0.95 0.95 Standard Deviation of SAA 0.94 0.97 Difference: α w 0.90 0.90 0.03 Absorption Coefficient (α) 1.30 1.20 1.10 1.00 0.90 0.80 0.70 0.60 0.50 0.40 0.30 0.20 0.10 0.00 100 125 160 200 250 315 400 500 630 800 10001250160020002500315040005000 Pyrotek Small-Scale Room Laboratory 1 Graph 2: The absorption coefficients measured within the Pyrotek small-scale room and independent laboratory 1 ACOUSTICS 2016 Page 5 of 10

9-11 November 2016, Brisbane, Australia Proceedings of ACOUSTICS 2016 5.2 Laboratory 2 Table 3: The absorption coefficients measured within the Pyrotek small-scale room and independent laboratory 2 Pyrotek Small-Scale Room Laboratory 2 Difference 100 0.04 0.04 0.00 125 0.11 0.13 0.02 160 0.22 0.23 0.01 200 0.36 0.46 0.10 250 0.57 0.72 0.15 315 0.86 0.92 0.06 400 1.10 1.09 0.01 500 1.17 1.17 0.00 630 1.16 1.09 0.07 800 1.08 0.95 0.13 1000 0.94 0.90 0.04 1250 0.93 0.87 0.06 1600 1.03 0.94 0.09 2000 1.05 0.91 0.14 2500 0.99 0.91 0.08 3150 1.01 0.92 0.09 4000 0.96 0.94 0.02 5000 0.99 0.96 0.03 NRC 0.95 0.95 Standard Deviation of SAA 0.94 0.91 Difference: α w 0.90 0.90 0.05 Absorption Coefficient (α) 1.30 1.20 1.10 1.00 0.90 0.80 0.70 0.60 0.50 0.40 0.30 0.20 0.10 0.00 100 125 160 200 250 315 400 500 630 800 10001250160020002500315040005000 Pyrotek Small-Scale Room Laboratory 2 Graph 3: The absorption coefficients measured within the Pyrotek small-scale room and independent laboratory 2 Page 6 of 10 ACOUSTICS 2016

Proceedings of ACOUSTICS 2016 9-11 November 2016, Brisbane, Australia 5.3 Laboratory 3 Table 4: The absorption coefficients measured within the Pyrotek small-scale room and independent laboratory 3 Pyrotek Small-Scale Room Laboratory 3 Difference 100 0.04 0.15 0.11 125 0.11 0.17 0.06 160 0.22 0.26 0.04 200 0.36 0.27 0.09 250 0.57 0.53 0.04 315 0.86 0.82 0.04 400 1.10 0.99 0.11 500 1.17 1.10 0.07 630 1.16 1.15 0.01 800 1.08 1.05 0.03 1000 0.94 0.90 0.04 1250 0.93 0.90 0.03 1600 1.03 0.97 0.06 2000 1.05 0.99 0.06 2500 0.99 0.96 0.03 3150 1.01 0.96 0.05 4000 0.96 0.94 0.02 5000 0.99 0.98 0.01 NRC 0.95 0.90 Standard Deviation of SAA 0.94 0.89 Difference: α w 0.90 0.85 0.03 Absorption Coefficient (α) 1.30 1.20 1.10 1.00 0.90 0.80 0.70 0.60 0.50 0.40 0.30 0.20 0.10 0.00 100 125 160 200 250 315 400 500 630 800 10001250160020002500315040005000 Pyrotek Small-Scale Room Laboratory 3 Graph 4: The absorption coefficients measured within the Pyrotek small-scale room and independent laboratory 3 ACOUSTICS 2016 Page 7 of 10

9-11 November 2016, Brisbane, Australia Proceedings of ACOUSTICS 2016 5.4 Laboratory 4 Table 5: The absorption coefficients measured within the Pyrotek small-scale room and independent laboratory 4 Pyrotek Small-Scale Room Laboratory 4 Difference 100 0.04 0.08 0.04 125 0.11 0.14 0.03 160 0.22 0.29 0.07 200 0.36 0.41 0.05 250 0.57 0.60 0.03 315 0.86 0.85 0.01 400 1.10 1.05 0.05 500 1.17 1.09 0.08 630 1.16 1.11 0.05 800 1.08 1.02 0.06 1000 0.94 0.96 0.02 1250 0.93 0.91 0.02 1600 1.03 0.98 0.05 2000 1.05 1.02 0.03 2500 0.99 1.00 0.01 3150 1.01 0.98 0.03 4000 0.96 1.03 0.07 5000 0.99 1.02 0.03 NRC 0.95 0.90 Standard Deviation of SAA 0.94 0.92 Difference: α w 0.90 0.90 0.02 Absorption Coefficient (α) 1.30 1.20 1.10 1.00 0.90 0.80 0.70 0.60 0.50 0.40 0.30 0.20 0.10 0.00 100 125 160 200 250 315 400 500 630 800 10001250160020002500315040005000 Pyrotek Small-Scale Room Laboratory 4 Graph 5: The absorption coefficients measured within the Pyrotek small-scale room and independent laboratory Page 8 of 10 ACOUSTICS 2016

Proceedings of ACOUSTICS 2016 9-11 November 2016, Brisbane, Australia Photograph 5 and 6: The Reapor panels mounted within the Pyrotek reverberation room during testing 6. DISCUSSION Whilst satisfactory correlation can be observed between the Pyrotek small-scale reverberation room and all four independent laboratories, the strongest correlation is with independent laboratory 4, as seen in table 5 and graph 5. This comparison had the lowest standard deviation of difference, an identical α w and a minor 0.02 difference in SAA. Although the NRC differs by 0.05, the actual difference is only 0.01 before rounding to the nearest 0.05 as stipulated in ASTM C423-09a. Variance between the measured results could be caused by a variety of factors. It is plausible that the general variance in the production of Reapor may have resulted in minor absorption performance differences. Furthermore, there is a degree of uncertainty for sound absorption measurements within reverberation rooms. Although it is not the focus of this paper, Fergus (2002), Ramis, Abla, Martínez & Redondo (2005), and many others have discussed this in detail. The focus material used in this paper has been Reapor, but other samples have been tested in the Pyrotek reverberation room which reveal similar correlation with full scale tests. However, at the time of writing, only nonfaced porous samples have been tested and compared to independent laboratories. Throughout all of our testing, variation in low frequency accuracy has been observed, although this been an expected property of the room since inception due to the small room volume. A prime example of this low frequency uncertainty is from a test as shown in graph 6. The test specimen was 50 mm thick Viterolite 600, a rigid homogeneous porous absorber with a density of 600 kg/m 3, which was also tested at independent laboratory 1 to allow comparison. Absorption Coefficient (α) 1.00 0.90 0.80 0.70 0.60 0.50 0.40 0.30 0.20 0.10 0.00 100 125 160 200 250 315 400 500 Graph 6: The absorption coefficients of 50 mm thick Viterolite 600 measured within the Pyrotek small-scale room and independent laboratory 1 630 800 1000 1250 1600 2000 2500 3150 Pyrotek Small-Scale Room Laboratory 1 4000 5000 ACOUSTICS 2016 Page 9 of 10

9-11 November 2016, Brisbane, Australia Proceedings of ACOUSTICS 2016 It was observed during our stages of diffusivity checks that results could appreciably differ depending on the quantity and layout of the diffusion panels. Although significant time was spent to achieve the level of diffusivity we have at the time of writing, we theorise that it could be plausible to improve the 95% confidence intervals with further adjustment of the diffusion panels. However, the small room volume and unfavourable shape of the room are factors which have a large influence on the performance of the room and cannot be controlled. For this reason, future attempts at further improving factors which we can control from this stage may be insignificant. 7. CONCLUSION A small-scale reverberation room was successfully created where we can test the sound absorption coefficients of materials during the research and development process, before sending the final material to an independent acoustical laboratory for accredited ISO 354:2003 results. This significant development provides the benefit of accelerating the research and development process, saving both time and resources. Although the small 48 m 3 room volume causes greater uncertainties at low frequencies, it has allowed for the reverberation room to be constructed rapidly and close to the research and development department. Table 6: A comparison of the calculated single-number absorption ratings Pyrotek Small- Scale Room Laboratory 1 Laboratory 2 Laboratory 3 Laboratory 4 NRC 0.95 0.95 0.95 0.90 0.90 SAA 0.94 0.97 0.91 0.89 0.92 α w 0.90 0.90 0.90 0.85 0.90 ACKNOWLEDGEMENTS The assistance and support from Benjamin Dowdell, Jo Hyeon Yoon, Angela Chen and Michael Kierzkowski of the Pyrotek Noise Control Research & Development Department and Philip Holgate of the Pyrotek Noise Control Engineering Department is gratefully acknowledged. REFERENCES International Organization for Standardization 2003, Acoustics Measurement of sound absorption in a reverberation room, ISO 354:2003, International Organization for Standardization, Geneva. ASTM International 2009, Standard Test Method for Sound Absorption and Sound Absorption Coefficients by the Reverberation Room Method, ASTM C423-09a, ASTM International, Philadelphia. ASTM International 2012, Standard Test Method for Impedance and Absorption of Acoustical Materials Using a Tube, Two Microphones and a Digital Frequency Analysis System, ASTM E1050-12, ASTM International, Philadelphia. International Organization for Standardization 1997, Acoustics Rating of sound absorption Materials and systems, ISO 11654:1997, International Organization for Standardization, Geneva. Fergus, F 2002, The Accuracy of Sound Absorption Measurements, Acoustics 2002 Annual Conference of the Australian Acoustical Society, 13-15 November 2002, Australian Acoustical Society, Adelaide, Australia. Ramis, J, Alba, J, Martínez, J & Redondo, J 2005, The uncertainty in absorption coefficients measured in reverberant chambers: A case study, Noise & Vibration Worldwide January 2005. Page 10 of 10 ACOUSTICS 2016