The ROXI Colorimeter & Fluorimeter. Laboratory Application I. Colorimetric measurements via Beer s Law.

Similar documents
CHEM 254 EXPERIMENT 9. Chemical Equilibrium-Colorimetric determination of equilibrium constant of a weak acid

Preparation of Standard Curves. Principle

Lab Investigation 4 - How could you make more of this dye?

EXPERIMENT #3 A Beer's Law Study

Experiment 7: Adsorption Spectroscopy I, Determination of Iron with 1,10 Phenanthroline

Chapter 18. Fundamentals of Spectrophotometry. Properties of Light

Determination of the Equilibrium Constant. HIn - + H 2 O = H 3 O + + In 2-, [H 3 O + ][In 2- ] K ai = [HIn - ]

Chem 321 Lecture 18 - Spectrophotometry 10/31/13

Beer's- Lambert Law and Standard Curves. BCH 312 [Practical]

Skill Building Activity 2 Determining the Concentration of a Species using a Vernier Spectrometer

Compact Knowledge: Absorbance Spectrophotometry. Flexible. Reliable. Personal.

MOLEBIO LAB #4: Using a Spectrophotometer

An Introduction to Ultraviolet-Visible Molecular Spectrometry (Chapter 13)

Concepts, Techniques. Concepts, Techniques 9/11/2012. & Beer s Law. For a simple, transparent, COLORED material, e.g. ROYGBV

Determining the Concentration of a Solution: Beer s Law

Chemistry 1215 Experiment #11 Spectrophotometric Analysis of an Unknown Brass Sample

1 st European Union Science Olympiad in Dublin, Ireland. task B

Experiment 7A ANALYSIS OF BRASS

Investigating Transition Metal Complexes

Lab #12: Determination of a Chemical Equilibrium Constant

Spectrophotometric Determination of Iron

The Fluorometric Determination of Acetylsalicylic Acid in an Aspirin Tablet

CHEM 334 Quantitative Analysis Laboratory

Chem 310 rd. 3 Homework Set Answers

Spectroscopy. Page 1 of 8 L.Pillay (2012)

ANALYSIS OF ZINC IN HAIR USING FLAME ATOMIC ABSORPTION SPECTROSCOPY

Spectrophotometry. Introduction

Experiment 18 - Absorption Spectroscopy and Beer s Law: Analysis of Cu 2+

Experiment 13I THE REACTION OF RED FOOD COLOR WITH BLEACH 1

Spectroscopy Meditsiiniline keemia/medical chemistry LOKT Spectroscopy

Experiment 1 (Part A): Plotting the Absorption Spectrum of Iron (II) Complex with 1,10- Phenanthroline

Introduction. The amount of radiation absorbed may be measured in a number of ways: Transmittance, T = P / P 0 % Transmittance, %T = 100 T

CHEMICAL KINETICS E + 2B 2C + D (1)

A Study of Beer s Law Prelab

Nucleic Acid Quantitation in Microplates

R O Y G B V. Spin States. Outer Shell Electrons. Molecular Rotations. Inner Shell Electrons. Molecular Vibrations. Nuclear Transitions

Atomic Absorption Spectroscopy and Atomic Emission Spectroscopy

MORE LIGHTS, COLOR, ABSORPTION!

Experiment 13H THE REACTION OF RED FOOD COLOR WITH BLEACH 1

Beer-Lambert law Decomposition of the manganese oxalate ion

Design and Development of a Smartphone Based Visible Spectrophotometer for Analytical Applications

UV/VIS SPECTROMETRIC DETERMINATION OF AN EQUILIBRIUM CONSTANT

AIM To verify Beer - Lambert s law and to determine the dissociation constant (Ka) of methyl red, Spectrophotometrically.

Basics of UV-Visible Spectroscopy *

Lambert s law. Beer s law. di x / I x = -kdx (-di x = k I x dx) = - a c dx. I/I 0 = e -kl T = A = - log (T) = - log (I/I 0 )

UV-Vis optical fiber assisted spectroscopy in thin films and solutions

10/2/2008. hc λ. νλ =c. proportional to frequency. Energy is inversely proportional to wavelength And is directly proportional to wavenumber

Experiment 6: Determination of the Equilibrium Constant for Iron Thiocyanate Complex

1. Preliminary qualitative analysis of unknown substances (liquid or solid).

DETERMINATION OF K c FOR AN EQUILIBRIUM SYSTEM

Reflection = EM strikes a boundary between two media differing in η and bounces back

Chem 321 Name Answer Key D. Miller

2014 NJIT RET Program. MODULE TOPIC: Two Methods of Determining the Concentration of Soluble Compounds or Analytes..

Reference literature. (See: CHEM 2470 notes, Module 8 Textbook 6th ed., Chapters )

Concentrations that absorb. Measuring percentage transmittance of solutions at different concentrations

CH 112 Special Assignment #4 Chemistry to Dye for: Part C

Beer s Law: Determining the Concentration of a Solution

Spectrophotometry Materials

Experiment 12: SPECTROSCOPY: EMISSION & ABSORPTION

FLAME PHOTOMETRY AIM INTRODUCTION

Spectroscopy of Atoms and Molecules

Expt 4: Determination of Iron by Absorption Spectrophotometry Calibration solutions: Iron(II)ammonium sulfate = ferrous ammonium sulfate

Investigating Food Dyes in Sports Beverages. Sample

Spectroscopy: Introduction. Required reading Chapter 18 (pages ) Chapter 20 (pages )

EXPERIMENT 14. ACID DISSOCIATION CONSTANT OF METHYL RED 1

Introduction to biochemical practicals. Vladimíra Kvasnicová

Experiment#1 Beer s Law: Absorption Spectroscopy of Cobalt(II)

Answers to spectroscopy questions. 1. Consider the spectrum below. Questions a f refer to this spectrum.

Colorimetric analysis of aspirin content in a commercial tablet

Determination of an Equilibrium Constant

Cork Institute of Technology. Summer 2005 Instrumental Analysis (Time: 3 Hours) Section A

EXPERIMENT 12 UV/VIS Spectroscopy and Spectrophotometry: Spectrophotometric Analysis of a Commercial Aspirin Tablet

Clinical Chemistry (CHE221) Professor Hicks Week 1. Statistics Made Slightly Less Boring and Introduction to Spectrophotometry. Accuracy vs Precision

CHEM Lab 7: Determination of an Equilibrium Constant using Spectroscopy

SPECTROPHOTOMETRY/BEER S LAW LECTURE HONORS CHEMISTRY NAME

Name Lab Exercise 2 - Standard Curves Nitrate, Ammonia, Phosphorus, and Chlorophyll

COLORIMETER AND LAMBERT S-BEER S LAW. Shingala vaishali Sandha prafulla Tiwari Kuldeep

Experiment 11 Beer s Law

Spectroscopy II Introduction: Spectrophotometry and Fluorometry

Introduction to Spectroscopy: Analysis of Copper Ore

Experiment 11 Beer s Law

CHM 152 updated May 2011 Lab 6: Experimentally Determining an Equilibrium Constant using Spectrophotometry

6. A solution of red Kool-Aid transmits light at a wavelength range of nm.

Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy. Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy

Three hour lab. Chem : Sept Experiment 2 Session 2. Preparation Pre-lab prep and reading for E2, Parts 3-5

The Spectrophotometer and Atomic Spectra of Hydrogen Physics 246

EXPERIMENT. Beer s Law

Experiment 2: The Beer-Lambert Law for Thiocyanatoiron (III)

Determination of the Solubility-Product Constant for a Sparingly Soluble Salt

INTRODUCTION The fundamental law of spectrophotometry is known as the Beer-Lambert Law or Beer s Law. It may be stated as: log(po/p) = A

Three hour lab. Chem : Feb Experiment 2 Session 2. Experiment 2 Session 2 Electrons and Solution Color

Chapter 17: Fundamentals of Spectrophotometry

Fluorescence Workshop UMN Physics June 8-10, 2006 Basic Spectroscopic Principles Joachim Mueller

Photochemistry of Nitro-Polycyclic Aromatic Hydrocarbons. August 9, 2011

Basic Instrumentation. Learning Objectives:

two slits and 5 slits

Bio 120 Lab 5: Quantitative Analysis

Analytical Chemistry II

A Classroom Experiment on Discoloration of Basic Phenolphthalein Solution for Demonstration of Reaction Kinetics

Determining Riboflavin Content in a Multivitamin: Things to do before the lab

Transcription:

The ROXI Colorimeter & Fluorimeter. Laboratory Application I. Colorimetric measurements via Beer s Law. Required Supplies & Costs: RGB LED; $1.95 Light Sensors; $3.95 ea 3-way switch; $6.54 3 ohm resistor; $.1 Arduino Uno; $24.95 1. Sensor Description. The sensor consists of a common cathode RGB light emitting diode (Sparkfun Electronics, https://www.sparkfun.com/products/15), and two logarithmic scale analog light sensors (Adafruit Industries, https://www.adafruit.com/products/1384). Peak wavelengths for emission by the LED are specified as 467.5, 52, 625 nm by the manufacturer. The light sensors are powered by 2.3-6 VDC, and produce an output voltage (Vout) that is linear with the logarithm of the light intensity incident upon the sensor. The light sensors are glued onto the side of a cuvette holder that was 3D printed. Two light sensors (shown in blue in figure below) are present. The first at 18 deg. to the incident beam is for transmittance / absorbance measurements. The second detector is placed at 9 deg. angle for fluorescence or light scattering measurements. A circuit diagram for the apparatus is shown below. A 3-way switch (NKK Switch, HS13Y) distributes power to the RGB LED with current controlled via a 3-ohm resistor at the common cathode. Each light detector is powered via 5VDC, and ground is common. Two analog input channels of the Arduino are devoted to voltage measurements from the sensors. cuvette holder light detectors Vcc GND R= 3 Ω Vcc GND Signals GND VS= 5V 3-way switch to distribute 5V to anode of desired color Figure 1. Schematic of the colorimeter / fluorimeter setup.

A) B) D) C) Figure 2. Photograph of (A) the Adafruit light sensor chip; (B) view from above of the 3D printed cuvette holder, (C) the cuvette holder with LED and light detectors affixed with JB Weld, (D) the colorimeter installed within the ROXI case. The label was printed and laminated prior to gluing to the plexiglass. Three thru holes are designed into the cuvette holder to allow for placement of the LED and two light detectors. Peak wavelengths for emission by the LED are specified as 467.5, 52, 625 nm by the manufacturer. 2. Calibration of the Colorimeter. After assembly, we desired to devise a method to calibrate, or check the accuracy of the light sensor by using samples of known transmittance. To accomplish this, various plastic filters manufactured by Lee Filters were used. The manufacturer of these filters kindly distributes transmittance spectra for their products (shown below), allowing a simple means to achieve a calibration standard. Several optical filters could be placed into the optical path sequentially and the change in detector signal observed. The accepted transmittance values and measured voltages were then plotted and an exponential fit applied to the data. The resulting best-fit function was subsequently used to determine % transmittance for samples. This allows a transmittance standard to establish the relationship between voltage and transmittance. Data collected for an example trial experiment is shown on the next two pages.

Information Regarding the Optical Filters (courtesy of Lee Filters) LED color Measured Voltage (V) 1.623 2.2295.98 Known Transmission 1.5% 83% %.5488 1.592.4949 % 8% % 1.9845.3577 1.744 12% % 5% 2.5431 2.121 2.2687 84% 47% n.a. 2.4794 2.121 2.619 6% 12% 79% 1.9649 2.426 8% % 42% 2.3373 2.5774 5% % 72% 1.9943 2.139 2.459 8% 35% 38% 2.2589 1.911 2.5235 3% 22% 59% Blank 1% T -53 nm 2.5921 1% Blank 1% T -467 nm 2.6558 1% Blank 1% T -63 nm 2.2785 1%

% Transmission 12 1 8 6 4 2 Channel y =.172e 3.2352x R² =.9975 1 2 3 sensor voltage (V) % Transmission 12 1 8 6 4 2 Channel y =.22e 4.1755x R² =.9832 1 2 3 sensor voltage (V) Transmission 12 1 8 6 4 2 Channel y =.339e 3.4571x R² =.9683 1 2 3 sensor voltage (V)

3. Experiment: Demonstration of Beer s Law. Introduction. The purpose of this experiment is to demonstrate the Beer-Lambert law relationship using the colored dye bromthymol blue and the ROXI colorimeter. Transmittance is defined as the fraction of incident electromagnetic power that is transmitted through a sample: Transmittance: T = where I, I are the transmitted and incident radiant powers, respectively. All spectrometers measure transmittance, but chemists frequently convert to absorbance since this variable is linearly related to the concentration of the absorbing substance: Absorbance: A= -log (T) A= 2 - log (%T) The Beer-Lambert law of optical absorption describes the linear relationship between absorbance (A) and concentration (c). Beer s law: A = ϵ b c In this equation, ε is a wavelength dependent number that describes the ability of the substance to absorb light, and b is the pathlength (cm) light travels through the sample. There is flexibility with what units of concentration can be used, however, if molarity is chosen ε is known as the molar absorptivity (L / mol cm). Procedure. 1. Dissolve approx. 15 mg of bromthymol blue (M.W. = 624.38 g/mol) in a 25. ml volumetric flask (water is solvent). Compute the exact molarity of the solution. 2. Obtain five 1 ml volumetric flasks. Transfer 1 ml, 2 ml, 3 ml, 4 ml, and 5 ml of the stock solution to volumetric flasks 1-5, respectively. 3. Fill the volumetric flasks to the mark using ph=1 ammonium chloride / ammonia buffer and mix well. Compute the exact concentrations of these solutions by using the dilution factors. 4. Turn on the ROXI colorimeter and set the color dial to red. Confirm the 1% T has been set. Recalibrate using transmittance standards if necessary. Zero the blank (buffer solution).

5. Use the ROXI colorimeter to measure the absorbance of the solutions using the red channel. 6. Use the data and concentrations to prepare a Beer s law plot of the data. 7. Obtain a solution of unknown concentration and test the unknown solution and measure the absorbance using the colorimeter. 8. If desired, the absorbance values measured with the ROXI colorimeter can be compared to measurements made with a laboratory spectrophotometer for quality control. Sample Data. Mass of Bromthymol used (g).161 Molar mass of Bromthymol blue (g/mol) 624.38 Moles of Bromthymol blue (mol).2578 Molarity of solution (mol/l).131 standard solutions concentration (mol/l) Absorbance measured via ROXI Absorbance measured via laboratory spectrophotometer (reference method) A.131.48.48 B.262.83.67 C.393 1.41.96 D.4124 2 1.28 E.5155 2.47 1.6 Abs./ A 3 2.5 2 1.5 1.5 Roxi Colorimeter y = 49989x -.11 R² =.9934.2.4.6 Conc. / M Abs./ A 2 1.5 1.5 Spectrophotometer @ 63 nm y = 2743x +.148 R² =.992.2.4.6 Conc. / M Unknown analysis ROXI laboratory spectrophotometer (reference method) Absorbance for unknown solution 1.1141.811 Unknown concentration from calibration curve (mol/l).2445.2417

4. Conclusion & Discussion. From the results of the analysis and the graph, it can be seen that the concentration was linearly proportional to absorbance as expected. The unknown solution tested had a true concentration of 2.47 x 1-5 M, very close to the measured values of 2.445 x 1-5 M and 2.417 x 1-5 M obtained by the ROXI colorimeter and the laboratory spectrometer. The concentration of an unknown sample could be determined with good accuracy (here 1%) using the ROXI colorimeter. However, the ROXI colorimeter data yielded a slope of the Beer s law plot considerably different from the laboratory spectrophotometer. The cause of the discrepancy is likely that the laboratory spectrophotometer was operated at 63 nm, a slightly larger wavelength than the LED. The slightly larger wavelength is on the rapidly falling edge of the absorption spectrum for the dye used. This will lead to a smaller slope of the Beer s law plot. Laboratory Application II. Fluorescence measurements. Introduction. For a demonstration of the ROXI fluorescence measurement we have prepared several different standard solutions of sodium fluorescein dye, placed them within a cuvette and illuminated the samples using the blue LED channel at λ=467 nm. The #735 Velvet (Lee Filters) plastic filter matches the emission spectrum of fluorescein well, and this filter was placed in front of the fluorescence detector to reduce excitation light. It was found that the observed signal voltage plotted vs. the logarithm of the concentration of fluorescein produced a linear response that could be used for simple analysis. Emission Filter Spectrum Sodium Fluorescein excitation and emission spectra Wavelength (nm)

Procedure. 1. Preparation of standard solution. Place approx..25g sodium fluorescein in a.25l volumetric flask. Dilute with D.I. water (approx. conc.= 1 µg / ml). 2. Preparation of standards for analysis. Transfer.1mL,.2 ml,.1 ml,.2 ml,.35 ml,.5 ml, 1mL from the stock solution to a 1 ml volumetric flask labeled A, B, C, D, E, F, G, respectively. 3. Fill the 1 ml flasks with buffer solution (ph=7, Na 2 HPO 4 /KH 2 PO 4 ) to the 1 ml mark and mix the solutions well. 4. Zero the blank using buffer solution and measure the voltage for each solution by using a cuvette and the ROXI fluorimeter. Sample Data. Observed Voltage (V) Fluorescein Concentration Voltage Response measured via ROXI (V) (µg/ ml).1.637.2.723 1.9653 2 1.125 3.5 1.197 5 1.2446 1 1.334 1.4 1.2 1.8.6.4.2-2 -1 1 2 Log [conc.]