Sample Alignment (2D detector) Part

Similar documents
Sample Alignment Part

Determination of the Rydberg constant, Moseley s law, and screening constant (Item No.: P )

Ocean Optics Red Tide UV-VIS Spectrometer (Order Code: SPRT-UV-VIS)

Newton's 2 nd Law. . Your end results should only be interms of m

Caution! Pay close attention to the special operation and safety instructions in the manual of the ultrasonic echoscope.

Inverted Pendulum System

2) Measure sample and empties. 3) Measure transmissions of sample and empties. 4) Normalize to exposure time and transmission. 5) Subtract the empties

Atomic and nuclear physics

CityGML XFM Application Template Documentation. Bentley Map V8i (SELECTseries 2)

Space Objects. Section. When you finish this section, you should understand the following:

ST-Links. SpatialKit. Version 3.0.x. For ArcMap. ArcMap Extension for Directly Connecting to Spatial Databases. ST-Links Corporation.

Leaf Spring (Material, Contact, geometric nonlinearity)

Atomic and nuclear physics

WindNinja Tutorial 3: Point Initialization

Jasco V-670 absorption spectrometer

Skin Damage Visualizer TiVi60 User Manual

Double Star Observations

Analyst Software. Automatic Optimization Tutorial

Lasentec Product Group

Swanning about in Reciprocal Space. Kenneth, what is the wavevector?

HOW TO ANALYZE SYNCHROTRON DATA

ISSP User Guide CY3207ISSP. Revision C

Information Dependent Acquisition (IDA) 1

Lasentec Product Group

1 Introduction to Computational Chemistry (Spartan)

Quick Start Guide New Mountain Visit our Website to Register Your Copy (weatherview32.com)

Alpha-energies of different sources with Multi Channel Analyzer (Item No.: P )

Protocol Particle size distribution by centrifugal sedimentation (CPS)

Task 1: Open ArcMap and activate the Spatial Analyst extension.

This experiment is included in the XRP 4.0 X-ray solid state, XRS 4.0 X-ray structural analysis, and XRC 4.0 X-ray characteristics upgrade sets.

Experiment C-10 Titration of a Strong Acid and a Strong Base

1. Starting of a project and entering of basic initial data.

X-RAY SPECTRA. Theory:

Catchment Delineation Workflow

Automatic Watershed Delineation using ArcSWAT/Arc GIS

Changing and challenging times for service crystallography. Electronic Supplementary Information

Winmostar tutorial LAMMPS Polymer modeling V X-Ability Co,. Ltd. 2017/7/6

KISSsys Tutorial: Two Stage Planetary Gearbox. Using this tutorial

X-ray diffraction geometry

Work and Energy. We re going to use the same apparatus that we used in last week s Newton s Laws lab. A string is attached to a car of mass m

O P E R A T I N G M A N U A L

LAB 2 - ONE DIMENSIONAL MOTION

version ISOL METHOD MASS SEPARATOR MASHA CHARGE STATES...5

Conservation of Mechanical Energy Activity Purpose

Graphical User Interfaces for Emittance and Correlation Plot. Henrik Loos

AKD SYSTEM CONFIGURATION WITH KOLLMORGEN DDL LINEAR MOTORS By Kenny Hampton 1/12/2017 Rev. L

PStress R Pulley Stress Analysis Software Users Manual*

Downloading GPS Waypoints

ON SITE SYSTEMS Chemical Safety Assistant

Polar alignment in 5 steps based on the Sánchez Valente method

PC Control / Touch Control

Absorption of X-rays

Determining the Concentration of a Solution: Beer s Law

Mnova Software for Analyzing Reaction Monitoring NMR Spectra

Geology 777 Monte Carlo Exercise I

Spectrometer User s Guide

Workshop 8. Lateral Buckling

WMS 10.1 Tutorial GSSHA Applications Precipitation Methods in GSSHA Learn how to use different precipitation sources in GSSHA models

Spread footing settlement and rotation analysis

TitriSoft 2.5. Content

How to Make Photometric & Colorimetric Measurements of Light Sources using an Ocean Optics Spectrometer and SpectraSuite Software

Data Structures & Database Queries in GIS

Microsystems Technology Laboratories i-stepperthursday, October 27, 2005 / site map / contact

Quick Start Guide. The ieq45 GoTo German Equatorial Mount # 8000C

Quantum States and Spectra of Gases

Alpha-Energies of different sources with Multi Channel Analyzer

SFT3000S Measurement of Sn-Cu Coating

Physical Structure of Matter. K a doublet splitting of molybdenum X-rays / fine structure Physics of the Electron.

Geology 554 -Wilson Environmental and Exploration Geophysics II Computer Lab - Seismic Resolution I

PHY222 Lab 2 - Electric Fields Mapping the Potential Curves and Field Lines of an Electric Dipole

2. To measure the emission lines in the hydrogen, helium and possibly other elemental spectra, and compare these to know values.

41. Sim Reactions Example

Ocean Optics Educational Spectrometers. Getting Started Manual

Watershed Modeling Orange County Hydrology Using GIS Data

Shear waves in solid-state materials

Determining the Concentration of a Solution: Beer s Law

SIERRA ANALYTICS, INC. Version Polymerix Software User Manual

Technical Procedure for Glass Refractive Index Measurement System 3 (GRIM 3)

How to create a new geodatabase using the extract data wizard. 1. How to Extract the Schema to create a Geodatabase using an existing design.

Coulomb s Law Mini-Lab

Automated trabecular and cortical bone selection

Table of content. Understanding workflow automation - Making the right choice Creating a workflow...05

Good Diffraction Practice Webinar Series

Task 1: Start ArcMap and add the county boundary data from your downloaded dataset to the data frame.

ELEC 1908 The Electric Potential (V) March 28, 2013

Conservation of Momentum Using PASCO TM Carts and Track to Study Collisions in One Dimension

R I T. Title: GCA Stepper Operations. Semiconductor & Microsystems Fabrication Laboratory Revision: F Rev Date: 08/09/ SCOPE

Instytut Fizyki Doświadczalnej Wydział Matematyki, Fizyki i Informatyki UNIWERSYTET GDAŃSKI

IN REPORT: Plate Scale and FOV of CCD for Each Telescope using Albireo Stars

Beer's Law and Data Analysis *

How to Create Stream Networks using DEM and TauDEM

Fixturlaser Alignment System

The CSC Interface to Sky in Google Earth

PACS Wavelength Switching AOT release note

OECD QSAR Toolbox v.4.1. Tutorial of how to use Automated workflow for ecotoxicological prediction

OASIS WIRELESS WEATHER STATION

CSCE 155N Fall Homework Assignment 2: Stress-Strain Curve. Assigned: September 11, 2012 Due: October 02, 2012

CE 365K Exercise 1: GIS Basemap for Design Project Spring 2014 Hydraulic Engineering Design

Magnetotellurics Impedance Tensor Tools (MITT)

St art. rp m. Km /h 1: : : : : : : : : : : : :5 2.5.

Transcription:

Sample Alignment (2D detector) Part

Contents Contents 1 How to set Part conditions...1 1.1 Setting conditions... 1 1.2 Customizing scan conditions and slit conditions... 6 2 Sample alignment sequence...13 2.1 Direct beam half cut alignment... 13 2.2 Surface normal alignment... 14 Sample Alignment (2D Energy Resolution) Part i

1.1 Setting conditions 1 How to set Part conditions In this chapter, how to set the Sample Alignment (2D detector) Part conditions is described. 1.1 Setting conditions Set the basic conditions in the Sample Alignment (2D detector) dialog box. The scan conditions and slit conditions of the sample alignment are determined based on the basic conditions. The scan conditions and slit conditions can also be customized. Fig. 1.1.1 Sample Alignment (2D detector) dialog box Sample thickness (mm) Enter the sample thickness. For a thin film sample, enter the overall thickness of the sample, including the thickness of the substrate. Direct beam half cut alignment conditions Check the Direct beam half cut alignment conditions box to execute the direct beam half cut alignment. Surface normal alignment conditions Check the Surface normal alignment conditions box to execute the surface normal alignment. Alignment criteria Select the alignment criteria of the surface normal alignment. Standard Fine Performs the surface normal alignment twice. Repeats the surface normal alignment up to five times until the alignment results converge. Sample Alignment (2D Energy Resolution) Part 1

1 How to set Part conditions Surface density Surface density Nominal density Select the nominal density of the surface layer from Very low, Low, Medium, or High. The 2-theta scattering angles, depending on the wavelength, shown in the table below are used for the surface normal alignment. 2-theta scattering angles Mo wavelength Cu wavelength Co wavelength Cr wavelength Very low 1.0 g/cm 3 or lower 0.09 deg 0.20 deg 0.23 deg 0.30 deg Low 1.0~2.5 g/cm 3 0.18 deg 0.40 deg 0.46 deg 0.59 deg Medium 2.5~4.0 g/cm 3 0.23 deg 0.50 deg 0.58 deg 0.74 deg High 4.0 g/cm 3 or higher 0.28 deg 0.60 deg 0.70 deg 0.89 deg Tip: When Surface density is set to Unknown, the surface normal alignment is performed at the 2-theta scattering angle used when Medium is selected for Surface density. A surface layer is a layer that is approximately 10 nm thick or greater and closest to the surface. For example, if the layer (layer 1) closest to the surface is 2 nm thick and the next layer (layer 2) is 30 nm thick, Surface density should be set to the density of the second layer. Clear omega offset Set chi, phi = 0 When the Clear omega offset box is checked, the sample alignment starts after setting the omega zero offset value to the value registered as the optics alignment result. When the Set chi, phi = 0 box is checked, the sample alignment starts after driving the chi and phi axes to the datum point (0, excluding the zero offset value). Tip: If the results of the previous sample alignment are kept, the next sample alignment uses this position as a reference and may not work correctly. In ordinary cases, check the Clear omega offset and Set chi, phi = 0 boxes. Run recommended sequence Performs the sample alignment using the recommended sequence. Customize conditions Performs the sample alignment under the conditions specified in the Customize dialog box. 2 Sample Alignment (2D Energy Resolution) Part

1.1 Setting conditions Customize When the Customize conditions radio button is selected, click the Customize button, then set the scan conditions and slit conditions. 1.2 Customizing scan conditions and slit conditions Tip: It is recommended to execute both the direct beam half cut alignment and the surface normal alignment unless there is a specific reason not to. Execute the surface normal alignment when a precise sample alignment is required by the application. Put a sample when the sample alignment starts. If the sample is mounted (or changed) before the sample alignment starts, check the Put a sample when the sample alignment box. If the sample alignment is performed using the currently-mounted sample, uncheck the Put a sample when the sample alignment box. Put a sample every time the sample alignment starts in a repeated measurement. If the sample is changed every time the sample alignment starts in a repeated measurement using the loop Parts or XY mapping Parts, check the Put a sample every time the sample alignment starts in a repeated measurement box. If the sample is mounted during the first cycle only, uncheck the Put a sample every time the sample alignment starts in a repeated measurement box. Execute Executes the sample alignment under the conditions specified in the Sample Alignment (2D detector) dialog box. CAUTION: Clicking the Cancel button after executing the sample alignment does not cancel the specified conditions. Tip: The sample alignment is executed with the Sample Alignment (2D detector) dialog box open. While the sample alignment is running, the Part conditions cannot be changed. They can be changed again after the alignment has been completed. The setting of invalid. (Show confirmation messages) on the flow bar becomes Sample Alignment (2D Energy Resolution) Part 3

1 How to set Part conditions Import Loads the saved Part conditions. Clicking the Import button opens the Import dialog box. Select the folder including the file you want to import from the Folder tree view. In the Condition file list, select the condition file you want to import and click the OK button to load the Part conditions. Export Saves the specified Part conditions in a file. Clicking the Export button opens the Export dialog box. From the Folder tree view, select a destination folder to save the conditions file then enter a file name in the File name box. Enter comments in the Memo box, if needed. After entering them, click the OK button. 4 Sample Alignment (2D Energy Resolution) Part

1.1 Setting conditions OK Sets the conditions and closes the dialog box. Cancel CAUTION: When selecting another Package measurement or switching the task to the Manual Control task, etc. the specified conditions will be cancelled. To save the specified conditions in a file, click the Export button and save the conditions. Does not set the conditions and closes the dialog box. Tip: Clicking the Cancel button also cancels the conditions specified in the Customize dialog box.? Opens the online help of this Part. Sample Alignment (2D Energy Resolution) Part 5

1 How to set Part conditions 1.2 Customizing scan conditions and slit conditions If you want to customize the scan conditions and slit conditions of the sample alignment, set the conditions in the Customize dialog box. Tip: Refer to 2 Sample alignment sequence to set the scan conditions and slit conditions. Fig. 1.2.1 Customize dialog box 6 Sample Alignment (2D Energy Resolution) Part

1.1 Setting conditions Sample thickness (mm) Enter the sample thickness in mm. For a thin film sample, enter the overall thickness of the sample, including the thickness of the substrate. Direct beam half cut alignment conditions Check the Direct beam half cut alignment conditions box to execute the direct beam half cut alignment. Surface normal alignment conditions Check the Surface normal alignment conditions box to execute the surface normal alignment. Alignment criteria Surface density Select the alignment criteria of the surface normal alignment. Standard Performs the surface normal alignment twice. Fine Repeats the surface normal alignment up to five times until the alignment results converge. Select the nominal density of the surface layer from Very low, Low, Medium, or High. The 2-theta scattering angles, depending on the wavelength, shown in the table below are used for the surface normal alignment. Surface density Nominal density Scattering angle 2-theta Mo wavelength Cu wavelength Co wavelength Cr wavelength Very low 1.0 g/cm 3 or lower 0.09 deg 0.20 deg 0.23 deg 0.30 deg Low 1.0~2.5 g/cm 3 0.18 deg 0.40 deg 0.46 deg 0.59 deg Medium 2.5~4.0 g/cm 3 0.23 deg 0.50 deg 0.58 deg 0.74 deg High 4.0 g/cm 3 or higher 0.28 deg 0.60 deg 0.70 deg 0.89 deg Tip: When Surface density is set to Unknown, the surface normal alignment is performed at the 2-theta scattering angle used when Medium is selected for Surface density. A surface layer is a layer that is approximately 10 nm thick or greater and closest to the surface. For example, if the layer (layer 1) closest to the surface is 2 nm thick and the next layer (layer 2) is 30 nm thick, the Surface density should be set to the density of the second layer. Sample Alignment (2D Energy Resolution) Part 7

1 How to set Part conditions Clear omega offset Set chi, phi = 0 When the Clear omega offset box is checked, the sample alignment starts after setting the omega zero offset value to the value registered as the optics alignment result. When the Set chi, phi = 0 box is checked, the sample alignment starts after driving the chi and phi axes to the datum point (0, excluding the zero offset value). Tip: If the results of the previous sample alignment are kept, the next sample alignment uses this position as a reference and may not work correctly. In ordinary cases, check the Clear omega offset and Set chi, phi = 0 boxes. IS (mm) IS L (mm) Alignment 2-Theta (deg) Enter the incident slit width. Enter the incident length limiting slit length. Enter the 2-theta scattering angle in degrees for the surface normal alignment. 8 Sample Alignment (2D Energy Resolution) Part

1.1 Setting conditions Direct beam half cut alignment measurement conditions Check the Direct beam half cut alignment measurement conditions box to execute the direct beam half cut alignment. Incident attenuator Intensity threshold (cps) Start (mm) Stop (mm) Step (mm) Duration time (sec) Delta (mm) Start (deg) Stop (deg) Step (deg) Duration time (sec) Delta (deg) Select ON when you use the incident attenuator for the direct beam half cut alignment. Select OFF when you don t use the incident attenuator. Enter the x-ray intensity. This value is used to interrupt scans after peak detection. Enter the start position of the Z scan. Enter the stop position of the Z scan. Enter the step width of the Z scan. Enter the duration time of the Z step. Enter the relative range of the second and subsequent Z scans. The value (position determined in the first scan) +/ (delta) is the scan range for the second and subsequent scans. Enter the start angle of the omega scan. Enter the stop angle of the omega scan. Enter the step width of the omega scan. Enter the duration time of the omega step. Enter the relative range of the second and subsequent omega scans. The value (position determined in the first scan) +/ (delta) is the scan range for the second and subsequent scans. Sample Alignment (2D Energy Resolution) Part 9

1 How to set Part conditions Surface normal alignment measurement conditions Check the Surface normal alignment measurement conditions box to execute the surface normal alignment. Incident attenuator Intensity threshold (cps) Repeat Start (mm) Stop (mm) Step (mm) Duration time (sec) Delta (mm) Exec. Start (deg) Stop (deg) Step (deg) Duration time (sec) Delta (deg) Select ON when you use the incident attenuator for the surface normal alignment. Select OFF when you don t use the incident attenuator. Enter an x-ray intensity. This value is used to interrupt axial scans after peak detection. Select the number of surface normal alignment to be repeated. Enter the relative distance of the start position of the Z scan from the position of the Z axis at the start of the scan. Enter the relative distance of the stop position of the Z scan from the position of the Z axis at the start of the scan. Enter the step width of the Z scan. Enter the duration time of the Z step. Enter the relative range of the second and subsequent Z scans. The value (position determined in the first scan) +/ (delta) is the scan range for the second and subsequent scans. Check the Exec. box to execute chi-axis alignment. Enter the relative distance of the start position of each scan from the position of the scan axis at the start of the scan. Enter the relative distance of the stop position of each scan from the position of the scan axis at the start of the scan. Enter the step width of each scan. Enter the duration time of each step. Enter the relative range of the second and subsequent scans of each axis. The value (position determined in the first scan) +/ (delta) is the scan range for the second and subsequent scans. 10 Sample Alignment (2D Energy Resolution) Part

1.1 Setting conditions Set recommended values Close Sets the conditions in the Slit conditions, Scattering angle for alignment, Direct beam half cut alignment measurement conditions, and Surface normal alignment measurement conditions sections to the recommended values based on the conditions specified in the Sample information and Surface normal alignment conditions sections. Closes the Customize dialog box. Sample Alignment (2D Energy Resolution) Part 11

2.1 Direct beam half cut alignment 2 Sample alignment sequence The sample alignment is performed automatically. However, the sample spacer, wafer sample plate, sample, and parts such as optical devices must be installed (or removed) manually as instructed by messages displayed on the screen. Described below is the general sample alignment sequence. 2.1 Direct beam half cut alignment (1) Install the sample spacer, wafer sample plate, sample, and incident length limiting slit as instructed by the messages displayed on the screen. (2) Adjust the incident slit widths as specified in the recommended or customized conditions. (3) Drive each axis of the goniometer to the initial position (2-theta = 0.0000, omega = 0.0000 ). (4) Scan the Z axis and determine the position at which the incident x-ray beam is blocked and reduced to 50% intensity by the sample. Fig. 2.1.1 Alignment based on Z scan (5) Drive the Z axis to the position determined in step (4). (6) Scan the omega axis and determine the position (profile peak position) at which the incident x-ray beam is parallel to the sample surface. Fig. 2.1.2 Alignment based on omega scan (7) Drive the omega axis to the profile peak position. (8) Repeat steps (4) through (7). (9) Repeat steps (4) and (5). Sample Alignment (2D Energy Resolution) Part 13

2 Sample alignment sequence (10) After the alignment has been completed, the sample surface is parallel to the incident x-ray beam. The sample surface also coincides with the center of rotation of the goniometer axes. Fig. 2.1.3 After alignment (11) Change the omega zero offset value so that omega is 0.0000 under the conditions described in step (10). 2.2 Surface normal alignment (1) Drive the 2-theta/omega axes to the alignment scattering angle specified in the recommended or customized conditions. (2) Scan the omega axis and determine the position (profile peak position) at which the incident angle of the x-ray beam on the sample surface equals half of the 2-theta scattering angle. Fig. 2.2.1 Alignment based on omega scan (3) Drive the omega axis to the profile peak position. (4) Scan the Z axis and determine the position (profile peak position) at which the sample surface coincides with the center of rotation of the goniometer axes. (5) Drive the Z axis to the profile peak position. Fig. 2.2.2 Alignment based on Z scan 14 Sample Alignment (2D Energy Resolution) Part

2.2 Surface normal alignment (6) Repeat the alignment process described in steps (2) through (5) for the number of times specified in the recommended or customized conditions. (7) After the alignment has been completed, the incident and exit angles of the x-ray beam on the sample surface are identical and equal to half of the scattering angle. The sample surface also coincides with the center of rotation of the goniometer axes. Fig. 2.2.3 After alignment (8) Change the omega zero offset values so that omega = 2-theta/2. (9) Drive the 2-theta/omega axes to 0.0000º. Sample Alignment (2D Energy Resolution) Part 15