IC Columns Introduction

Similar documents
groups I and II cations, amines, divalent transition metals

IC Section. Starter Kits IC SPE Standards EZ-LUTE Buffers Other Accessories

Alltech Ion Chromatography

Cation Exchange HPLC Columns

Cation Exchange HPLC Columns

Dionex IonPac AS28-Fast-4µm column

columns IonPac AS17-C Anion Exchange Column

Anion Exchange HPLC Columns

anion-exchange column

columns IonPac AS22 Anion-Exchange Column

columns IonPac AS18 Anion-Exchange Columns

Thermo Scientific Dionex IonPac AS23 Anion-Exchange Column

columns IonPac SCS 1 Silica Cation Separator

Thermo Scientific. Anion-Exchange Column. Determination of Inorganic Anions in Diverse Sample Matrices. Superior Chromatographic Performance

Thermo Scientific. Anion-Exchange Column

Alltech Alltima HP Introduction

INSTALLATION INSTRUCTIONS and TROUBLESHOOTING GUIDE. for the OnGuard- CARTRIDGE

Superior Chromatographic Performance Recommended anion-exchange column for separation of haloacetic acids prior to MS or MS/MS detection

Thermo Scientific Dionex IonPac AS25 Anion-Exchange Column. Minutes

Analysis - HPLC A.136. Primesep 5 µm columns B.136

Data Pack. Ion Chromatography Methods. June 2009

Rapid Post-Blast Inorganic Explosive Analysis by Suppressed Ion Chromatography

Ion Analysis of Hydraulic Fluids in Fracking Process

Efficient Separations Obtained by Using Smaller Particle Size Analytical Columns with a High-Pressure Ion Chromatography System

IC5000 Ion Chromatography System

4. Ion chromatography (IC) 4.1. Educational aims and objectives

Concentrator and Trap Columns. Column: IonPac AG15, AS15, 2 mm. Eluent Source: EG40 Concentrator. Temperature: 30 C Column: IonPac AC15 (2 50 mm)

columns I o n P a c AS11 and AS11-H C Anion-E x c h a n g e C o l u m n s

Thermo Scientific Dionex IonPac AS24A Anion-Exchange Column

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography

suppressors Eluent Suppressors for Ion Chromatography

Thermo Scientific Dionex IonPac AS26 Anion-Exchange Column

Overcoming Challenging Matrices in Ion Chromatography

Thermo Scientific Dionex IonPac AS11-HC-4µm Anion-Exchange Column

Chapter 9. Chemical Names and Formulas

High-Performance Chromatography Superior isocratic separation of

Theory of Ion Chromatography

Expanded capabilities in ammonium and amine detection

SeCtiOn 7 [STOCK AND CUSTOM] Ion Chromatography Single and Multi-Element Standards

Determination of Cations and Amines in Hydrogen Peroxide by Ion Chromatography Using a RFIC (Reagent-Free) System

Thermo Scientific Dionex Ion Chromatography Solutions. Global water safety. bromate analysis in drinking water

Anion and Cation analysis with Professional IC - automatic dilution and sample preparation with SPM

User Manual. IonPac NS2 Columns Revision 02 October For Research Use Only. Not for use in diagnostic procedures.

New On-Line High-Pressure Electrolytic Eluent Generators for Ion Chromatography

HPLC. Columns and Resins. For a Complete Range of Applications

Ion Chromatography *

Ions and Ionic Compounds

Ion Chromatography. Anion Exchange. Chromatography Ion Exchange Theory. Dr. Shulamit Levin

Chromatography Theory and Applications

Magnetic Flowmeter Material Selection Guide

Determination of trace anions in concentrated hydrofluoric acid

Thermo Scientific Dionex IonPac AS11 and AS11-HC Anion-Exchange Column

Nomenclature for ionic compounds

New Developments in Capillary Ion Chromatography using 4 μm Columns and Charge Detection

Thermo Scientific Dionex eluent suppressors for ion chromatography

Keywords Haloacetic acids, Water analysis, 2-D ion chromatography, ICS-3000

Waters. Ion Chromatography

CHEM 1105 S10 January 21, 2014

Anion Analysis of Ophthalmic Irrigation Solutions with the Shimadzu Prominence IC System Craig Young, PhD, Sr. Tech Support Specialist

Ion Analysis of Hydraulic Fluids in Fracking Process

Using a Reagent-Free ion chromatography system to monitor trace anion contamination in the extracts of electronic components

Chapter 5: Nomenclature

INSTRUCTIONS ON EVERY AP EXAM:

1 Introduction. 1.1 Historical Perspective

Ion Chromatography. Introduction

The column program. The whole world of ion chromatography

suppressors SRS -ULTRA Self-Regenerating Suppressor

Packings for HPLC. Packings for HPLC

The column program. The whole world of ion chromatography

AP Chemistry Summer Assignment

Aluminum Ammonium Sulfate 12 H2O Reagent ACS CAS No: Aluminum Nitrate Nonahydrate, Reagent ACS CAS No:

THE CATION MUST ALWAYS BE WRITTEN FIRST

Thermo Scientific Dionex IonPac CS17 Cation-Exchange Column

SPE Introduction. general chromatography. solid phase extraction. How to Choose an SPE Product. Solid-Phase Processing Methods

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Thermo Scientific Acclaim. Catalogue 9. Hichrom Limited

500 SERIES CHEMICAL RESISTANCE GUIDE

Determination of Common Inorganic Anions in Environmental Waters Using a Hydroxide Selective Column

LC and LC/MS Column Selection Flow Chart

Separation of heat stable amine salts in methyldiethanolamine (MDEA) solutions using high-pressure IC

Determination of Inorganic Anions in Drinking Water by Ion Chromatography

Inline sample preparation for the determination of anions in sodium hydroxide

HPLC COLUMNS. HPLC Columns & Bulk Resins THE MEASURE OF EXCELLENCE TM

Safety Manual > Incompatible Chemicals Partial Listing

Determination of Bromate in Bottled Mineral Water Using the CRD 300 Carbonate Removal Device

Determination of Trace Cations in Power Plant Waters Containing Morpholine

Method Development with ZirChrom's Ion Exchange Phases

- Some MOLECULES can gain or lose electrons to form CATIONS or ANIONS. These are called POLYATOMIC IONS

UNIT 8: CHEMICAL FORMULAS AND NOMENCLATURE CHEMISTRY 215, DUFFEY

Unit 8: Ionic Compounds Notes and Practice

- Use the STEM NAME of the element, then add "-ide" suffix

Acclaim Mixed-Mode WAX-1 Columns

Name HONORS CHEMISTRY / / Oxide Reactions & Net Ionic Reactions

Experiment #4. Chemical Nomenclature

- Some MOLECULES can gain or lose electrons to form CATIONS or ANIONS. These are called POLYATOMIC IONS

Polyatomic Ions. Why? Model 1 Types of Ions. Can a group of atoms have a charge?

For new orders of the following parts discussed in this manual, please use the updated part numbers listed below.

PRODUCT MANUAL OMNIPAC PCX-500 GUARD COLUMN (PCX-500 GUARD, P/N ) OMNIPAC PCX-500 ANALYTICAL COLUMN (PCX-500 ANALYTICAL, P/N )

Thermo Scientific. Acclaim Trinity P2. Column Product Manual. P/N: October Part of Thermo Fisher Scientific

CHEM 1364 Test #1 (Form A) Spring 2010 (Buckley)

PRODUCT MANUAL. OMNIPAC PAX-100 GUARD COLUMN (4 x 50 mm, P/N ) OMNIPAC PAX-500 GUARD COLUMN (4 x 50 mm, P/N )

Transcription:

IC Columns Introduction Alltech IC Column Specifications Column Composition ph Range Applications Anion Exchange Columns Allsep polymer-based anion ph 0 inorganic anions, weak and strong acid ions, exchanger, μm metal complexes, organic acids Allsep A- polymer-based anion ph inorganic anions, organic acids, suitable for exchanger, μm both weak and strong anions in a single run Novosep A- polymer-based anion ph inorganic anions and oxyhalides; ideal for exchanger, 5μm separation of seven common anions plus three oxyhalide anions in one run AN polymer-based anion exchanger, 9μm Anion/S silica-based anion exchanger, 0μm Anion/R polymer-based anion exchanger, 0μm PRP -X00 polymer-based anion exchanger, 0μm Cation Exchange Columns Universal Cation silica-based cation exchanger, μm Universal Cation silica-based cation HR exchanger, μm PRP -X00 polymer-based cation exchanger, 0μm Organic Acid Columns PRP -X00 polymer-based sulfonated cation exchanger Anion Exclusion polymer-based cation exchanger, 0μm Specialty Columns Transition Metal silica-based reversedphase, μm and μm Surfactant/R Surfactant C Surfactant C polymer-based reversed-phase, μm silica-based reversedphase, 5μm silica-based reversedphase, 5μm EPA Methods Optimized for Suppressed or Non-Suppressed 00.0, Part A both 99 00.0, both 99 Part A 00.0, suppressed 00 00.,.0,.0 ph inorganic anions, weak and strong acid ions, both 00 organic acids ph 5.5 inorganic anions non-suppressed 0 ph inorganic anions, weak and strong acid ions non-suppressed 0 ph inorganic anions, weak and strong acid ions non-suppressed 0 ph ph ph groups I and II cations, amines, divalent transition metals groups I and II cations, amines, divalent transition metals; smaller particle size for improved peak resolution groups I and II cations (separate runs), amines, lanthanides Page 00. both 0 00. both 0 non-suppressed 0 ph simple aliphatic carboxylic acids and alcohols non-suppressed 0 ph organic acids, weak acid anions non-suppressed 04 ph high capacity, separates divalent transition metals and metal-cyano complexes more selectively than a cation exchange column non-suppressed 04 ph 4 anionic and cationic surfactants; separate both 05 short and long chain surfactants in one gradient run ph short chain anionic surfactants non-suppressed 05 ph long chain or aromatic anionic surfactants non-suppressed 05 IC Guard Kits Cross Reference Kit includes holder and three guard cartridges. Guard Reference Table Guard Cartridge Type All-Guard Kit Part No. Brand Column Type Alltech Allsep, Allsep A- GA- 09 Novosep A- GA- 09 Anion/R, Anion/S GA- 09 Universal Cation GC- 09 Universal Cation HR GC- 5 Anion Exclusion GIE- Transition Metal C GRP- Surfactant/R GRP- Surfactant C, C GRP- Dionex IonPac AS4A-SC, AS, AS, GA- 09 AS, AS4, AS, AS IonPac CS, CS0, CS GC- IonPac CS, CS4, CS5 GC- 09 IonPac NS GRP- IonPac AS, AS5 GIE- Guard Reference Table (continued) Guard Cartridge Type All-Guard Kit Part No. Brand Column Type Waters IC-Pak -A GA- 09 IC-Pak -M/D GC- 09 Ion Exclusion GIE- Hamilton PRP -X00 GA- 09 PRP -X00 GC- PRP -X00 GIE- Misc. Sarasep ANIONSEP AN GA- 09 Bio-Rad, Aminex, HPX- GIE- Interaction ION-0 GA- 09 Interaction ION-0 GC- Interaction ORH-0 GIE- Metrohm Metrosep GA- 09 more info Cartridges and holders can also be purchased separately. See specific phase pages for replacement cartridge ordering information. 9

Alltech Anion Columns Allsep Anion IC Columns Resolves fluoride away from the water dip Meets requirements for U.S. EPA Method 00.0 part A The Allsep Anion Column is compatible with common IC mobile phases: carbonate, bicarbonate, p-hydroxybenzoic acid, phthalic acid, succinic acid, and sodium octane sulfonate. Use this column for performing EPA Method 00.0 Part A Determination of Inorganic Anions in Water per U.S. EPA guidelines. 4 Resolves Fluoride Away from the Water Dip 5 0. Fluoride. Chloride. Nitrite 4. Bromide 5. Nitrate. Phosphate. Sulfate Allsep A- Anion IC Columns Separates both weak and strong acid anions in one run Resolves formate away from fluoride and chloride The Allsep A- Anion Column separates both weakly retained organic and strongly retained inorganic anions in one run. The high capacity Allsep A- Anion Column is also suitable for the separation of chlorite and chlorate. 4 5 Organic and Inorganic Anions 9 0 4. Fluoride (.0ppm). Acetate (.0ppm). Formate (.0ppm) 4. Chlorite (.0ppm) 5. Chloride (.0ppm). Nitrite (.0ppm). Bromide (.0ppm). Chlorate (5.0ppm) 9. Nitrate (.0ppm) 0. Phosphate (.0ppm). Sulfate (.0ppm) 0 4 0 4 0 4 Min. 0 4 Min. Allsep Anion, μm, 4. x 00mm (Part No. 50) 0.5mM NaHCO/0.9mM NaCO.mL/min Suppressed Allsep A- Anion, μm, 4. x 00mm (Part No. 59).mM NaHCO/.mM NaCO.0mL/min Suppressed Allsep Anion Specifications Methacrylate based w/quaternary ammonium functional groups μm Mobile Phase Limits: ph 0, 0 00% organic modifier Allsep A- Anion Specifications Methacrylate based w/quaternary alkanol amine functional groups μm Mobile Phase Limits: ph, 0 00% organic modifier Allsep Anion Columns Allsep Anion 4. x 0mm 5 5 4. x 50mm 5 54 4. x 00mm 50 500 4. x 50mm 509 50 Allsep A- Anion Columns Allsep A- 4. x 50mm 5 50 4. x 00mm 59 5 Guards for Allsep and Allsep A- Columns GA- Anion Cartridges 0 All-Guard Cartridge Holder* ea 00 99

Alltech Anion Columns Novosep A- Anion IC Columns Separates seven inorganic anions and three oxyhalide anions in a single run Meets the requirements of U.S. EPA Methods 00.0, 00.,.0, and.0 The Novosep A- Anion Column is ideal for the separation of 0 inorganic anions by suppressor-based ion chromatography using U.S. EPA Method 00.. The column can also be used to determine inorganic anions in drinking water per U.S. EPA Method 00.0 and trace bromate in drinking water using U.S. EPA Methods.0 and.0. Anions in High Ionic Strength Water by EPA Method 00.0 4 5 9 0 0. Fluoride. Chlorite. Bromate 4. Chloride 5. Nitrite-N. Bromide. Chlorate. Dichloroacetate 9. Nitrate-N 0. Phosphate-P. Sulfate IC Sep AN IC Column Separates anions with carbonate/bicarbonate and hydroxide mobile phases The IC Sep AN Column is compatible with both suppressor-based and non-suppressed detection. A variety of mobile phases including sodium carbonate/bicarbonate, sodium hydroxide, and borate/gluconate may be used. Separation of Sulfite and Sulfate 4 5. Fluoride. Chloride. Nitrite 4. Bromide 5. Nitrate. Phosphate. Sulfite. Sulfate 0 4 0404 Min. 0 4 0 4 Min. Novosep A- Anion, 5μm, 4.0 x 50mm (Part No. 540).mM NaHCO 0.mL/min Suppressed IC Sep AN, 9μm, 4. x 50mm (Part No. 40).mM NaHCO,.mM NaCO.0mL/min Suppressed Novosep A- Anion Specifications Polyvinyl alcohol-based w/quaternary ammonium functional groups 5μm Mobile Phase Limits: ph, 0 00% organic modifier, 0% modifier is practical upper limit IC Sep AN Specifications Poly(styrene-divinylbenzene) alkyl dimethyl ethanol ammonium functional group 9μm Exchange Capacity: 0.05meq/g Mobile Phase Limits: ph, No organic solvents Novosep A- Anion Column Packing i.d. x Length PEEK Part No. Novosep A- 4.0 x 50mm 540 Guards for Novosep A- Anion Columns GA- Anion Cartridges 0 All-Guard Cartridge Holder* ea 00 more applications To view our complete searchable chromatogram database visit /chromdb/ IC Sep AN Columns Packing i.d. x Length Part No. AN 4. x 50mm 40 Choose a guard column or integral guard discs to protect your IC Sep Column. IC Sep Guards Guard Column, 50 x 4.mm ea 45 Guard Column Guard-Disc 5 4 00

Alltech Anion Columns Anion/S IC Columns Silica-based for symmetrical peak shapes Separates inorganic and organic anions The Anion/S Columns are best suited for routine separations of chloride, bromide, nitrate, and sulfate. Not suitable for fluoride analysis. 4 0 4 0 4 Min. EDTA and Other Anions 4. Nitrite. EDTA. Nitrate 4. Bromide Anion/S, 0μm, 4. x 00mm (Part No. 90).5mM Sulfuric Acid.0mL/min UV at 0nm Anion/R IC Columns Polymer-based for broad ph stability Separates seven common inorganic anions Because of their high ph stability, these columns are ideal for the separation of anions using high ph mobile phases such as p-hydroxybenzoate, sodium hydroxide, and sodium carbonate/bicarbonate. The larger dimension columns (50mm and 50mm) are suitable for a high-resolution separation of the seven common inorganic anions. 45 Weak Acid Anions 59. Borate (5ppm). Silicate (0ppm). Formate (0ppm) 4. Sulfide (0ppm) 5. Chloride (0ppm). Cyanide (0ppm) Anion/S Specifications Exchange Capacity: Mobile Phase Limits: Silica w/quaternary ammonium ion exchanger 0μm 0.5meq/g ph 5.5, 0 00% organic modifier 0 9 Min. Anion/R, 0μm, 4. x 50mm (Part No. 909) 4mM Sodium Hydroxide/ 0.mM Sodium Benzoate.5mL/min Anion/S Columns Anion/S 4. x 00mm 90 90 4. x 50mm 90 900 Anion/R Specifications Exchange Capacity: Mobile Phase Limits: Poly(styrene-divinylbenzene) Trimethylammonium 0μm 0.9 ± 0.0meq/g ph, 0 00% organic modifier Anion/R Columns Anion/R 4. x 00mm 90 4. x 50mm 909 4. x 00mm 90 4. x 50mm 904 Guards for Anion/S and Anion/R Columns GA- Anion Cartridges 0 All-Guard Cartridge Holder* ea 00 0

Alltech Cation Columns Universal Cation and Universal Cation HR IC Columns Separate Groups I and II cations in one isocratic run Separate transition metals without post-column reaction New Universal Cation HR μm particle size for improved efficiency Compatible with a variety of mobile phases including complexing acids (citric acid, tartaric acid, oxalic acid), mineral acids (nitric acid, hydrochloric acid, sulfuric acid) and non-complexing organic acids (methanesulfonic acid). 4. Lithium (0.ppm). Sodium (.5ppm). Ammonium (.5ppm) 4. Potassium (.5ppm) 5 Metal Ions 0 4 0404 0 Min. 9 0 5. Nickel (.5ppm). Zinc (.5ppm). Cobalt (.5ppm). Magnesium (.0ppm) 9. Calcium (.0ppm) 0 4 5 9 04 5 Min. 4 5 Cesium and Strontium Universal Cation, μm, 4. x 00mm (Part No. 0) mm Methanesulfonic Acid.0mL/min 05. Lithium (0.ppm). Sodium (0.90ppm). Ammonium (0.90ppm) 4. Potassium (.5ppm) 5. Cesium (0.ppm). Magnesium (.ppm). Calcium (.ppm). Strontium (.ppm) Universal Cation, μm, 4. x 00mm (Part No. 0) mm Tartaric Acid/mM Oxalic Acid.0mL/min Universal Cation Specifications Silica coated with polybutadiene/maleic acid copolymer μm and μm, spherical Mobile Phase Limits: ph, 0 00% organic modifier Rapid Analysis of Monovalent and Divalent Cations 0. Lithium. Sodium. Ammonium 4. Potassium 5. Magnesium. Calcium Universal Cation Columns μm 4. x 00mm 0 00 μm HR 4. x 00mm 00.0 x 5mm 09 technical assistance Contact Tech Support: Phone:.00.55.4 (North America) Email: contact.alltech@grace.com Online: Universal Cation HR, μm,.0 x 5mm (Part No. 09) mm Methanesulfonic Acid.5mL/min more applications To view our complete searchable chromatogram database visit /chromdb/ Guards for Universal Cation Columns GC- Universal Cation 00 GC- Universal Cation HR 0 All-Guard Cartridge Holder* ea 00 0

Hamilton Anion, Cation, and Organic Acid Columns PRP -X00 Anion Columns High ph stability makes this column ideal for the separation of weak anions. PRP TM -X00 provides excellent resolution for the seven most frequently analyzed inorganic anions. For non-suppressed analyses only. PRP -X00 Cation Analysis Columns For separation of the alkali metal and alkaline earth cations in separate runs. PRP -X00 Organic Acid Columns For separation of simple aliphatic carboxylic acids and alcohols. Inorganic anions are not retained. EDTA in Eye Drops 0. CuEDTA Hamilton PRP -X00 Specifications Trimethylammonium psdvb copolymer 0μm, spherical Exchange Capacity: 0.9meq/g Mobile Phase Limits: ph, 0 00% organic modifier Hamilton PRP -X00 Specifications Sulfonated psdvb copolymer 0μm, spherical Exchange Capacity: 0.5meq/g Mobile Phase Limits: ph, 0 00% organic modifier Hamilton PRP -X00 Specifications Sulfonated psdvb in H+ form μm and μm Mobile Phase Limits: ph, 0 00% organic modifier Alkali Metals 504. Lithium. Sodium. Ammonium 4. Potassium 5. Cesium 4 5 0 4 0 Min. PRP -X00, 0μm, 4. x 50mm (Part No. 944) 0.00N Sulfuric Acid ml/min UV at 54nm 0 4 5 Min. PRP -X00, 0μm, 4. x 50mm (Part No. 944) 0.004N HNO in 0% MeOH ml/min Hamilton PRP -X00 Columns Packing i.d. x Length Part No. PRP -X00. x 50mm 94. x 50mm 94 4. x 00mm 949 4. x 50mm 944 4. x 50mm 94 Hamilton PRP -X00 Columns Particle Size i.d. x Length Part No. PRP -X00. x 50mm 994. x 50mm 94 4. x 50mm 944 4. x 50mm 944 Hamilton PRP -X00 Columns Particle Size i.d. x Length Part No. PRP -X00, μm 4. x 50mm 99 PRP -X00, μm 4. x 50mm 944 4. x 50mm 945 4. x 50mm 945 Hamilton PRP -X00 Guard Kits and Cartridges Guard Column Starter Kit ea 944 PRP -X00, Holder, Cartridges Replacement Guard Cartridges (Requires Hamilton Guard Holder) PRP -X00, 5 x.mm 5 944 Hamilton PRP -X00 Guard Kits and Cartridges Guard Column Starter Kit ea 945 PRP -X00, Holder, Cartridges Replacement Guard Cartridges (Requires Hamilton Guard Holder) PRP -X00, 5 x.mm 5 9449 Hamilton PRP -X00 Guard Kits and Cartridges Guard Column Starter Kit ea 940 PRP -X00, Holder, Cartridges Replacement Guard Cartridges (Requires Hamilton Guard Holder) PRP -X00, 5 x.mm 5 945 0

Alltech Anion Exclusion Columns Separate organic acids and weak acid anions Polymer-based for broad ph stability Economical choice for small inorganics Anion Exclusion Columns separate organic acids and weakly ionized anions by an anion exclusion mechanism. Dilute mineral acids are the typical mobile phases for the separation. Acetonitrile may be used as an organic modifier to decrease the retention of hydrophobic compounds. Organic Acid Standards 0. Oxalic Acid. Maleic Acid. Malic Acid 4. Succinic Acid 5. Formic Acid. Acetic Acid Alltech Transition Metal Columns Separate divalent transition metals and metal-cyano complexes more selectively than a cation exchange column To separate divalent transition metals, use conductivity detection for concentrations as low as ppm, or UV detection with post-column reaction for ppb-level concentrations To separate metal-cyano complexes, use the Alltech low UV IPC A (Part No. 549) as the ion-pair reagent, and methanol or acetonitrile as the organic modifier. Metal-Cyano Complexes 55 4 5 0 4 0 4 Min.. Fe(CN) 4-. Ag(CN) -. Fe(CN) - 4. Ni(CN)4-5. Au(CN) - Anion Exclusion, 0μm,.5 x 00mm (Part No. 90).5mM Sulfuric Acid 0.4mL/min Anion Exclusion Specifications Highly sulfonated poly (styrene-divinylbenzene) cation exchanger 0μm Mobile Phase Limits: <0% acetonitrile, no methanol <5% isopropyl or ethyl alcohols Anion Exclusion Columns Anion Exclusion, 0μm.5 x 00mm 909.5 x 00mm 90. x 00mm 90. x 00mm 900 Anion Exclusion All-Guard Cartridges Anion Exclusion GIE- All-Guard Cartridge Holder* ea 00 Transition Metal C, μm, 4. x 50mm (Part No. 90) 0.005M Tetrabutylammonium Sulfate (Preformulated Alltech Low UV IPC A, Part No. 549) in 0% Acetonitrile 0.mL/min UV at 4nm Transition Metal Specifications Silica-based with C bonded phase (0% Carbon) μm and μm, spherical Mobile Phase Limits: ph Transition Metal Columns Packing i.d. x Length PEEK Part No. C, μm 4. x 00mm 904 C, μm 4. x 50mm 90 Transition Metal All-Guard Cartridges GRP- Revised Phase 9 All-Guard Cartridge Holder* ea 00 04

Alltech Surfactant Columns Surfactant/R IC Columns Separate anionic and cationic surfactants Separate short and long chain surfactants in one gradient run The Surfactant/R Column separates anionic and cationic surfactants by ion-pair chromatography along with suppressed conductivity detection. This column can also be used for other reversed-phase applications. Short and Long Chain Cationic Surfactants 4 5 0. Tetramethyl Ammonium (0ppm). Tetraethyl Ammonium (0ppm). Tetrapropyl Ammonium (0ppm) 4. Tetrabutyl Ammonium (0ppm) 5. Dodecyltrimethyl Ammonium (0ppm). Cetyltrimethyl Ammonium (40ppm). Myristyltrimethyl Ammonium (50ppm) Surfactant/C IC Columns For non-suppressed analyses Silica-based for symmetrical peak shapes Choose Surfactant C for short chain anionic surfactants such as alkyl sulfates and alkyl sulfonates. Choose Surfactant C for long chain or aromatic surfactants such as xylene sulfonate and dodecyl benzene sulfonate. Alkyl Sulfates 599. Octyl Sulfate. Decyl Sulfate. Dodecyl Sulfate 0 4 0 4 0 Min. Surfactant/R Column, μm, 4. x 50mm (Part No. 50) A: mm Nonafluoropentanoic Acid B: 00% Acetonitrile Gradient: Time: 0 5 0 %B: 0 0 5 0.0mL/min Suppressed 0 4 0 Min. Surfactant/R Specifications Polydivinylbenzene (DVB) based resin μm Mobile Phase Limits: ph 4, 0 00% organic modifier Surfactant C, 5μm, 4. x 50mm (Part No. 90) 0.0g/L Ammonium Acetate in 40% Methanol.mL/min Surfactant/R Columns Surfactant/R, μm 4. x 50mm 50 500 Guards for Surfactant/R Columns GRP- Revised Phase 4 All-Guard Cartridge Holder* ea 00 more applications To view our complete searchable chromatogram database visit /chromdb/ Surfactant/C Specifications Silica-based C or C 5μm Mobile Phase Limits: ph, 0 00% organic modifier Surfactant/C Columns C, 5μm 4. x 50mm 90 909 C, 5μm 4. x 50mm 90 909 Guards for Surfactant/C Columns GRP- Revised Phase 9 All-Guard Cartridge Holder* ea 00 05