Proceedings of Shanghai 2017 Global Power and Propulsion Forum 30 th October 1 st November, 2017 http://www.gpps.global GPPS-2017-30 EXPERIMENTAL INVESTIGATION OF HEAT TRANSFER CHARACTERISTICS IN JET IMPINGEMENT COOLING SYSTEM WITH PIN FINS AND FILM COOLING HOLES Yu Rao Gas Turbine Research Institute, Shanghai Jiao Tong University yurao@sjtu.edu.cn Shanghai, China Yuyang Liu Gas Turbine Research Institute, Shanghai Jiao Tong University liuyuyang@sjtu.edu.cn Shanghai, China ABSTRACT An experimental study has been conducted on the heat transfer performance in a multiple-jet impingement cooling system with pin fins and film cooling extraction. Transient liquid crystal thermography experiment were conducted to explore the heat transfer characteristics on these target plates. The ratio of jet-to-plate spacing was fixed to 1.5 and the Reynolds number based on jet diameter ranges from 15,000 to 30,000. The experimental results show that pin fin and effusion holes structure reduces crossflow strength in downstream region, improves and uniforms heat transfer on the whole target plate obviously. When Re j =15,000, there is a highest improvement in heat transfer on the endwall. Compared with flat plate, the averaged Nusselt number on the pin fin plate and the pin fin plate with effusion holes can be improved by up to 6.3% and 25.3%. Furthermore, threedimensional CFD analysis was done to analyze the detailed flow structure and heat transfer characteristics in the impingement cooling systems with pin fins and film cooling extraction on the target plates. INTRODUCTION Advances in gas turbine technology for both aircraft propulsion and power generation are focused on increasing efficiency as well as maintaining or extending parts service life, and the key to improve efficiency is to increase the inlet gas temperature of turbine. The latest generation aircraft engine turbine inlet gas temperature exceeds 1700 [1], which is much higher than melting temperature of material. Therefore, more efficient and advanced cooling technologies are urgently needed to ensure the safe and reliable operation for gas turbines. Impingement cooling is one of the most effective internal cooling methods. When the coolant flows through narrow impingement holes, high-velocity jets directly impinge on target plate surface, the flow boundary layer is very thin and high heat transfer coefficient can be obtained. In early stage, the research on impingement cooling characteristics has already begun. Factors like geometry of impingement hole, jet-to-plate spacing ratio, jet velocity and cross flow have been studied successively [2-6]. Impingement cooling on flat plate often has poor local heat transfer characteristics at non-stationary locations and thus affects the service life of materials seriously. Some scholars tried to combine impingement cooling with ribs, which not only increases the heat transfer area but also improves the turbulence in the cavity, so as to achieve the enhanced heat transfer. Chang et al. [7] experimentally found that placing rib between two jets can obtain better heat transfer performance. They also established corresponding formulas based on experimental data. Andrews et al. [9] reported that keeping the ribs spanwise direction consistent with the crossflow direction can achieve better heat transfer performance. Son et al. [10] have studied the impingement cooling on rough target plate surface using transient liquid crystal thermography method. The results show that employing circular and diamond ribs on flat plate can increase heat transfer performance by 22%-35%. Xing et al. [11] described heat transfer distribution on structured surface with micro-rib by transient liquid crystal thermography experiment. A more efficient cooling technology is the combination of impingement cooling and film cooling. The arrangements of effusion holes may change flow field of the impingement cooling system, which is less considered in former studies. On the other hand, double wall cooling is an efficient cooling technology for next generation aircraft engine and gas turbine [12-13]. Thus, in this paper, impingement heat
transfer performance in a double-wall cooling system with pin fins and effusion holes was studied. Heat transfer, pressure loss and flow structure characteristics were investigated by experiments and numerical computations. EXPERIMENT SETUP A schematic of experimental device is given in Fig.1. The airflow is drawn into the wind tunnel by a variable frequency blower and its mass flow rate is measured by a vortex flowmeter. Then, the air temperature is heated up to around 45, after getting through a high-power mesh heater. The wind tunnel is made of 15mm thickness Plexiglas, which provides good thermal insulation for the test section. After passing through a channel, the air flows then into the inlet plenum and enters the test section. The test section is equipped with thermocouples, pressure holes and target plates with thermograph liquid crystal, shown in Fig. 2. The measured data is transmitted to a LABVIEW data acquisition system and recorded. At last, the fluid flows into outlet plenum and setting chamber to exit. A 3CCD camera is placed at the back of outlet plenum, and colour changes on the target plate surface can be clearly recorded during the experiment through the outlet plenum wall made of high transparent Plexiglas. Lights are installed on each side of the test section to make the colour bright, and the test section is covered with black opaque screen to avoid interference from ambient light. Figure 2 Schematic of test section (a) Pin fin plate Figure 1 Schematic of experimental setup Three target plates are used in the experiments, which are the flat plate, pin fin plate and pin fin plate with effusion holes. The target plates are made of 20mm thickness Plexiglas and all the pin fin structure are designed to be fullhigh, which connects the impingement plate and target plate without gaps. The geometric structures of pin fin plate and pin fin plate with effusion holes are shown in Fig. 3. Besides, the ratio of jet to plate spacing H / D j is equal to 1.5, D D 10mm, P / D 5 and P / D 5. P e X P Y P (b) Pin fin plate with effusion holes Figure 3 Schematic of target plates The method of transient liquid crystal thermography (TLC) is used to determine the heat transfer in the jet impingement system, which is referred to Ireland [14]. The liquid crystal was sprayed uniformly on the surface of target plate endwall. Since the measurement time is short, the heat transfer in the Plexiglas target plate can be considered as a transient heat conduction process of one dimensional half infinite plate, which can be described by equation (1): 2 T T k c. (1) z 2 t Boundary conditions are: t 0, T T 0 T z 0, k h( TB Tw) z z, T T0 Because the heat transfer on the surface of pin fin and effusion holes does not satisfy the one-dimensional heat conduction hypothesis, the heat transfer characteristics on 2
endwall is only measured in this experiment. By solving equation (1), the dimensionless temperature at the wall is obtained: Tw T0 2 t t 1 exp(h ) erfc( h ) T T k c k c B 0. (2) Eq. (2) is only valid for an ideal temperature step rise within the flow. However, in reality the thermocouples record a time-dependent variation of the mainstream temperature, which can be simulated by a series of small temperature step rise. By using Duhamel s superposition theorem, the solution for the heat transfer coefficient at every location is then represented as: N 2 ( t ti) ( t ti) w 0 B, i B, i 1 i 1 k c k c T T [1 exp( h ) erfc(h )]( T T ) Solving Eq. (3) by an iteration method, the heat transfer coefficient h can be determined. The jet Reynolds number is defined as: VD j j Re j. (4) The local Nusselt number is defined as: hd j Nu. (5) The experimental uncertainties have been determined using Kline and McClintock s method [15]. According to the measurement instruments, the maximum measurement uncertainties of the flow rate are 2.0%, the length as well as the pressure drop are 1.0% and 2.5% respectively; The measurement uncertainty in temperature are 0.3, time detection is 0.1 s, and the air properties are 1.0%, and the thermal conductivity of the Plexiglas is 0.01W/ (m K). The uncertainty due to the lateral conduction in the test plate can be below 2.0%. Therefore according to the standard uncertainty analysis, the measurement uncertainties of Re j and Nu are respectively about 3.0% and 8.5%. NUMERICAL SETUP In order to obtain a thorough understanding of the flow structure and heat transfer details in the impingement cooling system, three-dimensional steady CFD simulation was carried out. ANSYS CFX 14.5 was used for calculation, and k-omega SST turbulence model was chosen. Since this paper is focused on the internal heat transfer in a double-wall cooling structure, the simulation domain does not include the fluid within effusion holes, which is set to be pressure outlet, and the pin fin surface is adiabatic. To be more similar with experiment, the inlet plenum is taken into account for CFD model. The geometric model and boundary conditions are shown in figure 4. (3) Figure 4 Schematic of computational model and boundary conditions The grid first layer spacing of end wall surface is 0.01mm for structural mesh, thus averaged Y plus is less than 2 to meet the requirements of k-omega SST model. Grid independence check for pin fin plate has been done, and the difference of physical values between three meshes (cell sizes from 7.3 mil. to 12.0 mil.) is less than 1%. Figure 5 shows GCI analysis [17] of the three meshes at Re j =15,000, which indicates grid number has little influence on the physical values. Figure 5 GCI analysis for spanwisely averaged Nusselt numbers on pin fin plate at Re j =15,000 RESULTS AND DISCUSSION Experimental results Figure 6 shows the local Nusselt number distribution on the endwall, which is obtained by liquid crystal thermograph experiment at Re j =30,000. The Nusselt numbers reach high values at the jet stagnation points and decreases rapidly from centre to around. From upstream to downstream, with increasing cross flow strength, the Nusselt numbers increase firstly and then reach maximum value at the fourth stagnation region. Then, with the cross flow getting further stronger in downstream region, jets become offset and the Nusselt numbers decease. The existence of pin fins and effusion holes structure makes the jet stagnation region move towards upstream, indicating that downstream crossflow effects is reduced. On the other hand, in the diagonal area between jets there are usually low heat flux regions. The structure of pin fin and effusion hole makes the airflow mix in these regions, thus improves and uniforms heat transfer. 3
Figure 6 Experimental data of local Nusselt number distributions on target plates at Re j =30,000 Figure 8 shows the Nusselt number ratio and pressure loss ratio compared with flat plate. From Figure 8 (a), it can be seen that pin fin and effusion holes structure improves the heat transfer on the endwall, and the heat transfer enhancement decreases as the jet Reynolds number increases. When Re j =15,000, compared with flat plate there is a highest heat transfer enhancement and the averaged Nusselt number of pin fin plate and pin fin plate with effusion holes improves by 6.3% and 25.3% respectively. While when Re j =30,000, the improvements are 0.7% and 13.2% respectively. From Figure 8 (b), it can be seen that pressure loss of pin fin plate is higher than flat plate by 18.0% while pressure loss of pin fin plate with effusion holes is less than flat plate by 7.3% at Re j =15,000. Besides, the pressure loss ratio is almost independent of jet Reynolds number. (a) Averaged Nusselt number ratio Figure 7 Comparisons of experimental data of averaged Nusselt numbers on endwall Figure 7 gives a comparison of experimental data of heat transfer on the flat plate with literature data from Ei-Gabry [18], and the averaged Nusselt numbers on pin fin plate and pin fin plate with effusion holes are also provided. It can be seen that in this paper averaged Nusselt number on flat plate agree reasonably well with the literature data, and the pin fin plate with effusion holes has maximum averaged heat transfer values while the flat plate has minimum averaged heat transfer values at the same jet Reynolds number. Besides, the heat transfer correlations have been given for the pin fin plates and pin fin plate with effusion holes, which were based on experimental data. Pin fin plate: 0.73 1/3 Nu 0.081Re Pr,15,000 Re 30,000. (6) Pin fin plate with effusion holes: 0.69 1/3 Nu 0.102Re Pr,15,000 Re 30,000. (7) Figure 7 also provides the fitted curve for the correlations above, which agree well with experimental data, with deviation no more than 5.8%. (b) Pressure loss ratio Figure 8 Comparisons of experimental data of the structural target plates with flat plate Numerical results In order to strengthen the understanding of flow features in impingement cooling systems, CFD analysis was done. Figure 9 shows the local Nusselt number distribution on the endwall of target plates obtained by CFD. Figure 10 provides a comparison of spanwisely averaged Nusselt numbers on the endwall of flat plate obtained from experiments and CFD. It can be seen that the experimental and numerical results agree reasonably well with each other, with deviation no more than 8.1%. 4
impingement onto the pin fin plate with effusion holes, because the existence of effusion holes reduces the cross flow in downstream region obviously. For pin fin plate with effusion holes, the vortex is closer to the pin fin surface and impingement plate compared with the flat plate and pin fin plate, indicating that the crossflow effects are reduced. Due to the influence of cross flow, the mass flow of different impingement holes is different. As can be seen from Figure 13, the flow rate reaches the maximum value at the fourth impingement hole and is relatively lower at the third and fifth holes. Figure 9 Local Nusselt number distribution from CFD results on target plates at Re j =30,000 (a) Flat plate Figure 10 Spanwisely averaged Nusselt number on flat plate obtained from experiment and CFD at Re j =30,000 Figure 11 shows three-dimensional pathlines between the third and fourth jet in the impingement cooling system. From Figure 11 (a) it can be seen that on the surface of flat plate wall flow firstly washes against the endwall surface, then collides with the upstream wall flow produced by the downstream jet, which makes it separates from the wall and forms a vortex. From Figure 11(b) it can be known that on the surface of pin fin plate the initial formation stage of wall flow is similar to that of flat plate, however, a horseshoe vortex is generated near the end of pin fin and the heat transfer in this area is strengthened. Then the horseshoe vortex develops downstream and forms another vortex at the edge of downstream stagnation region. Figure 11(c) makes it clear that on the surface of pin fin plate with effusion holes the flow field shows a different pattem. The collision of the upstream and downstream jet occurs almost in the middle of two stagnation regions, and the downstream jet can also impinge onto the lower parts of upstream pin fins and enhances the heat transfer in this region. Figure 12 shows distributions of absolute velocity ratio and streamlines in the longitudinal central plane at Re j =30,000. The effect of cross flow is not obvious for jet (b) Pin fin plate (c) Pin fin plate with effusion holes Figure 11 Three-dimensional pathlines in the jet impingement system at Re j =30,000 5
51176111). The contributions to the work by Dr. Chaoyi Wan is appreciated. Figure 12 Distributions of absolute velocity ratio and streamlines in the longitudinal central plane at Re j =30,000 NOMENCLATURE D j Impingement jet diameter [mm] D P Pin fin diameter [mm] D e Effusion hole diameter [mm] H Jet-to-plate spacing [mm] P X Pin fin s streamwise spacing [mm] P Y Pin fin s spanwise spacing [mm] c Heat capacity [W/ (kg K)] h Heat transfer coefficient [W/ (m 2 K)] k Wall conductivity [W/ (m K)] Fluid conductivity [W/ (m K)] Density [kg/m 3 ] Dynamic viscosity coefficient [m 2 /s] z Coordinate along the plate depth [m] Re j Reynolds number, based on jet diameter Nu Local Nusselt number, based on jet diameter Nu Spanwisely averaged Nusselt number Nu Area-averaged Nusselt number t Time [s] T w Wall temperature [K] T B Jet airflow temperature [K] T 0 Initial wall temperature [K] P Pressure loss [pa] V Jet inlet velocity [m s -1 ] j Figure 13 CFD results of mass flow rate distribution through the jet holes in the jet impingement system at Re j =30,000 CONCLUSIONS In this paper, transient liquid crystal thermography experiment and numerical method were conducted in a jet impingement cooling structure with pin fins and film cooling effusion holes. The ratio of jet-to-plate spacing is fixed to 1.5 and the Reynolds number based on jet diameter ranges from 15,000 to 30,000. The experiment shows that pin fin and effusion holes structure obviously reduce the crossflow in downstream region, improves and uniforms the heat transfer on the endwall of target plate. The averaged Nusselt numbers of pin fin plate and pin fin plate with effusion holes are higher than that of flat plate by up to 6.3% and 25.3% respectively. Pressure loss of pin fin plate is more than that of flat plate by about 18.0% while pressure loss of pin fin plate with effusion holes is less by 7.3%. Flow structures, heat transfer features and mass flow distribution of impingement cooling in a double-wall structure are obtained by CFD analysis. Detailed interactional information between the wall flow, pin fin and effusion holes are expounded. Acknowledgement The research work was funded by the National Natural Science Foundation of China (Funding No.: 51676119 & REFERENCES [1] Hada S, Tsukagoshi K, and Junichiro M, Test results of the world s first 1600C J-series gas turbines, J MHI Technical Review, 2012, 49(1), pp 18-23. [2] Lee DH, Song J, and Jo MC, The effects of nozzlesurface separation distance on impingement jet heat transfer and fluid flow, J ASME Journal of Heat Transfer, 2004, 126, pp 554-557. [3] Katti V, and Prabhu SV, Influence of spanwise pitch on local heat transfer distribution for in-line arrays of circular jets with spent air flow in two opposite directions, J Experimental Thermal and Fluid Sciences, 2008, 33, pp 84-95. [4] Chambers AC, Gillespie DRH, and Ireland PT, The effect of initial cross flow on the cooling performance of a narrow impingement channel, J Journal of Heat Transfer, 2005, 127(4), pp 358-365. [5] Taslim ME, Setayeshgar L, and Spring SD, An experimental evaluation ofadvanced leading edge impingement cooling concepts, J Journal of Turbomachinery, 2001, 123 (1), pp 147 153. [6] Taslim ME, Bakhtari K, and Liu H, Experimental and numerical investigation of impingement on a rib-roughened leading-edge wall, C ASME Turbo Expo 2003, collocated with the 2003 International Joint Power Generation Conference, 2003, pp 31-41. [7] Chang H, Zhang D, and Huang T, Impingement heat transfer from rib roughened surface within arrays of circular 6
jet: the effect of the relative position of the jet hole to the ribs, ASME paper, 1997, No.97-GT-331. [8] Chang H, Zhang D, and Huang T, Experimental investigation on impingement heat transfer from rib roughened surface within arrays of circular jet, ASME paper, 1998, No, 97-GT-208. [9] Andrews G, Abdul HR, and Mkpadi MC, Enhanced impingement heat transfer: comparison of co-flow and crossflow with rib tabulators, J Proceedings of IGTC2003, 2003. [10] Son C, Ireland P, and Gillespie D, The effect of roughness element fillet radii on the heat transfer enhancement in an impingement cooling system, C ASME Turbo Expo, 2005, pp 263-273. [11] Xing Y, Spring S, and Weigand B, Experimental and numerical investigation of impingement heat transfer on a flat and micro-ribs roughened plate with different crossflow schemes, J International Journal of Thermal Sciences, 2011, 50(7), pp 1293-1307. [12] Devore MA, and Paauwe CS, Tuebine airfoil with improved cooling, U.S. Patent, 2009, No. 7600966 B2. [13] Chyu MK, and Siw SH, Recent Advances of Internal Cooling Techniques for Gas Turbine Airfoils, ASME J. Thermal Sci. 2013, 5(2), pp 021008. [14] Ireland PT, and Jones TV, Liquid crystal measurements of heat transfer and surface shear stress, Meas. Sci. Technol, 2000,11, pp 969-986. [15] Kline SJ, and McClintock FA, Describing uncertainties in single-sample experiments, J Mechanical Engineering, 1953, 75, pp 3-8. [16] Kingsley-Rowe JR, Lock GD, and Owen JM, Transient heat transfer measurements using thermochromic liquid crystal: lateral-conduction error, J International Journal of Heat and Fluid Flow, 2005, 26(2), pp 256-263. [17] Roache PJ, Perspective: a method for uniform reporting ofgrid refinement studies, J Journal of Fluids Engineering, 1994, 116(3), pp 405-413. [18] Ei-Gabry LA, and Kaminski DA, Experimental investigation of local heat transfer distribution on smooth and roughened surfaces under an array of angled impingement jets, J Journal of Turbomachinery, 2005, 127(3), pp 532-544. 7