Slide 1. Slide 2. Slide 3. Choosing and Using the Best Sensor Technologies for Marine Chemistry Applications

Similar documents
Questions, Myths and Misconceptions about Using Photoionization Detectors

Understanding catalytic LEL combustible gas sensor performance

Choosing the best detection technologies for measuring combustible gas and VOC vapors

RS DYNAMICS ECOPROBE 5. Portable IR/PID Gas Analyzer PID. PID and IR Analyzers

Catalytic bead sensors are used primarily to detect

UV Hound Series. Dependable High Quality Air Monitoring. Accurate Readings Within Seconds. Portable UVDOAS Multi-gas Analyzers. Multi-Gas Capability

Training Coarse ECOPROBE 5 CHEMISTRY RS DYNAMICS

Atmospheric Analysis Gases. Sampling and analysis of gaseous compounds

Sub-category: Physics and Principles of Measurement Topic: Monitoring anesthetic gases and vapours Date: January 15-17, 2016 Language: English

Monitoring Flammable Vapors and Gases in Industrial Processes

New advances in folded pathlength technology for Process Tunable Diode Laser Absorption Spectrometers (TDLAS)

Sampling for Gases and Vapors

Technical/Application Article 01 Version 1.2

Alphasense Ltd. Compliance Statements and Certificates. Contents. The Restriction of the Use of Certain Hazardous Substances (RoHS)...

Combustible Gas Catalytic Bead (0-100 %LEL) Part No FM Performance Certified 1,4 FM Performance Certified 1

Using 11.7eV PID Lamps To Accurately Measure VOCs With Ionization Energy Above 10.6eV

Cracking. 191 minutes. 186 marks. Page 1 of 27

UV3000. Accurate, precise, and portable ambient gas point analyzer

Assessing Unknown Odors and Chemicals

Measurement Technique and its Application to Trace Components of Atmospheric Gas

Chapter 9 Oxidation-Reduction Reactions. An Introduction to Chemistry by Mark Bishop

a) ion-ion attractions b) London dispersion forces c) hydrogen bonding forces d) dipole-dipole attractions

White Paper. Overview: NDIR Definition:

National 5 Whole Course Revision Questions

Understanding ammonia sensors and their applications

Chapter 7. Oxidation-Reduction Reactions

Q1. Which one of the following is least likely to occur in the reaction between methane and chlorine?

5 Energy from chemicals

1.11 Redox Equilibria

Far UV Absorbance Detector

Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 23: GAS CHROMATOGRAPHY

Chem 321 Name Answer Key D. Miller

Name May 2, 2012 Physical Behavior of Matter and Bonding Review

Chemistry A: States of Matter Packet Name: Hour: Page 1. Chemistry A States of Matter Packet

CHEMISTRY HIGHER LEVEL

Elements and Their Oxides

Page 2. The hydrocarbon but-1-ene (C 4H 8) is a member of the homologous series of alkenes. But-1-ene has structural isomers.

Introduction to Chemical Reactions. Chapter 6

Name May 2, 2012 Physical Behavior of Matter and Bonding Review

C (s) + O 2 (g) CO 2 (g) S (s) + O 2 (g) SO 2 (g)

Strategies For Selecting Air Sampling Methods AIHA-Florida Section Spring Conference

MASS and INFRA RED SPECTROSCOPY

HOW ADVANCED PYROMETERS INCREASE THERMAL PROCESS REPEATABILITY AND PRODUCT QUALITY


Assessment Schedule 2015 Chemistry: Demonstrate understanding of aspects of carbon chemistry (90932)

ISA QATAR : 90 th Seminar

ICSE Board Class X Chemistry Board Paper Time: 1½ hrs Total Marks: 80

GCSE OCR Revision Chemistry. GCSE OCR Revision Chemistry. GCSE OCR Revision Chemistry. Bonding. GCSE OCR Revision Chemistry

N Goalby chemrevise.org

Period 11: Chemical Energy and Fossil Fuels

Test Booklet. Subject: SC, Grade: HS 2009 End of Course Chemistry. Student name:

Based on the kinetic molecular theory of gases, which one of the following statements is INCORRECT?

Organic Chemistry. Alkanes are hydrocarbons in which the carbon atoms are joined by single covalent bonds.

Reaction Rates and Chemical Equilibrium

Reaction Rates and Chemical Equilibrium

Gaseous CEMS technology

Gas Sensors and Solar Water Splitting. Yang Xu

OH, is an important feedstock for the chemical industry.

Proportions to find moles Correctly organized Example. Problem

Chemical Reactions (Chapter 13)

Unit Five: Intermolecular Forces MC Question Practice April 14, 2017

Chapter 19. Molecules and Compounds

Chapter 8: Energy from Electron Transfer

Use your knowledge of organic reaction mechanisms to complete the mechanism for this step by drawing two curly arrows on the following equation.

Chemistry 40S Chemical Kinetics (This unit has been adapted from

AASS, Örebro University

Chemistry Standard level Paper 1

Rates of Reaction HL

3.2 Alkanes. Refining crude oil. N Goalby chemrevise.org 40 C 110 C 180 C. 250 C fuel oil 300 C 340 C. Fractional Distillation: Industrially

Exampro GCSE Chemistry

Edexcel Chemistry Checklist

CHEMISTRY HIGHER LEVEL

Topics to Expect: Periodic Table: s, p, d, f blocks Metal, Metalloid, Non metal, etc. Periodic Trends, Family names Electron Configuration: Orbitals a

A Level Chemistry. Ribston Hall High School. Pre Course Holiday Task. Name: School: ii) Maths:

Chromatographic Methods of Analysis Section: 5 Gas Chromatography (GC) Prof. Tarek A. Fayed

MC 17 C SECTION - I (40 marks) Compulsory : Attempt all questions from this section.

1. A. Define the term rate of reaction. The measure of the amount of reactants being converted into products per unit amount of time

Nomenclature. 133 minutes. 130 marks. Page 1 of 22

H 8. ) is a member of the homologous series of alkenes. But-1-ene has structural isomers (2)... (1)...

Volatile Organic Compounds (VOC) Probes

Balancing chemical reaction equations (stoichiometry)

Introduction to electrochemistry

Reactions continued. And chemical review!!

PAPER 2 MAY/JUNE SESSION hour

AUTOMATED ONLINE IDENTIFICATION AND MONITORING OF IMPURITIES IN GASES

CHEMISTRY. SCIENCE Paper 2

ALE 1. Chemical Kinetics: Rates of Chemical Reactions

Chem 12: Chapters 10, 11, 12, 13, 14 Unit 3 Worksheet

Test Booklet. Subject: SC, Grade: HS CST High School Chemistry Part 2. Student name:

IV. DIRECT MEASUREMENT LABS. Introduction

# Ans Workings / Remarks

High Pressure/Performance Liquid Chromatography (HPLC)

AP Chem Chapter 14 Study Questions

e - Galvanic Cell 1. Voltage Sources 1.1 Polymer Electrolyte Membrane (PEM) Fuel Cell

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

Chemistry: The Central Science. Chapter 20: Electrochemistry

Unit 6 Solids, Liquids and Solutions

Page 2. Q1.Which of these substances does not contribute to the greenhouse effect? Unburned hydrocarbons. Carbon dioxide. Water vapour. Nitrogen.

Gas Laws. Bonding. Solutions M= moles solute Mass %= mass solute x 100. Acids and Bases. Thermochemistry q = mc T

This place covers: Electrolytic production of inorganic compounds, of non-metals and of organic compounds

Transcription:

Slide 1 Choosing and Using the Best Sensor Technologies for Marine Chemistry Applications Bob Henderson, BS, MBA GFG Instrumentation Inc. Ann Arbor, MI Toll free: 800-959-0329 Mobile: 734-355-1291 E-mail: bhenderson@gfg-inc.com GfG website: www.goodforgas.com Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 1 Slide 2 GfG Instrumentation World-wide manufacturer of gas detection solutions Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 2 Slide 3 GfG Instrumentation Exceptional designs with best cost of ownership in the gas detection industry Aug September 5, 201512, 2014 Best Sensor GfG Technologies Instrumentation for Marine company Chemistry overviewapplications Slide Slide 3 3

Slide 4 GfG, Inc. www.goodforgas.com website Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 4 Slide 5 Technical support and downloads www.goodforgas.com Manuals Software and software updates Data sheets Training materials and presentations Application Notes and Technical Notes: http://www.goodforgas.com/byproduct/ appnotes.htm Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 5 Slide 6 Multigas detectors GfG multi-gas instruments are compact, reliable and simple to operate. Loud audible and bright visual alarms give immediate warning of up to 6 gas hazards at the same time.

Slide 7 Available for use with a wide range of dependable, substance specific electrochemical sensors Optional range and resolution available for many sensors Plug-and-play sensor design makes changing or replacing sensors a snap MICRO IV Single Sensor Gas Detector Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 7 Slide 8 Interchangeable rechargeable (NiMH) or alkaline battery packs last over 20 hours per charge Top-mounted, three color, full graphics LCD Durable IP-67 water resistant design O 2 sensor rated for continuous use in 30 C temperatures G450 / G460 Multi-Gas Detector Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 8 Slide 9 Available sensors include: O 2 NO Catalytic LEL NO 2 Infrared LEL HCL Infrared CO 2 HF CO EtO H 2S O 3 COSH COCl 2 PID HBr SO 2 THT Cl 2 and more! ClO 2 NH 3 H 2 G460 Interchangeable Plug-and-Play Smart Sensors PH 3 HCN Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 9

Slide 10 Calibration adapters Sampling probes Leather holsters Calibration kits Other accessories Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 10 Slide 11 Measuring Oxygen (Deficiency and Enrichment) Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 11 Slide 12 Sensor generates electrical current proportional to the O 2 concentration Sensor used up over time (one to three years) Oxygen reduced to hydroxyl ions at cathode: O 2 + 2H 2O + 4e - 4OH - Hydroxyl ions oxidize lead (anode): 2Pb + 4OH - 2PbO + 2H 2O + 4e - Overall cell reaction: 2Pb + O 2 2PbO Fuel Cell Oxygen Sensors Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 12

Slide 13 Oxygen Sensor Major components of a fuel cell type oxygen sensor Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 13 Slide 14 Most O 2 sensors have a capillary pore used to allow sensor to self-stabilize at new pressure O 2 sensors with capillary pore are true percent by volume measurement devices Are able to self stabilize to changes in pressure due to Stabilization at new pressure is not instantaneous, may take 30 seconds or longer Rear vent allows faster stabilization, with less stress to internal components Rear vent 2015 AIHA PDC 415: Methods and Applications for Chemical Detection in Real Time Slide 14 Capillary pore (located under external moisture barrier filter) Slide 15 Response of G460 equipped with O2-A3 and 4OX-V sensors to changes in pressure Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 15

Slide 16 Oxygen Pump Detection Principle Oxygen passively diffuses into polymer (catalyst) substrate Power from instrument battery used to pump the oxygen back out Reactions: Oxidation / Reduction of target gas by catalyst Sensing: O 2 + 4H + + 4e - 2 H 2O Counter: 2 H 2O O 2 + 4H + + 4e - Oxygen generated on counter electrode Amount electricity required to remove reaction product and return sensor to ground state (by generating O 2 at counter electrode) proportional to concentration of oxygen present Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 16 Slide 17 Advantages: Oxygen Pump Sensor Advantages and disadvantages Non-consuming detection technique (sensor does not lose sensitivity or consume itself over time) Disadvantages / concerns: Detection reaction may be influenced by shifts in humidity and density Sensor is net consumer of electricity (drain on power supply) Important to ensure that reaction product (H 2O) is removed from sensor Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 17 Slide 18 G460 with 4OX-LL (lead free) O 2, O2-A3 (fuel cell) O 2 and IR CO 2 sensors exposed to 100% volume N 2 Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 18

Slide 19 G460 with O2-A3 oxygen and carbon dioxide sensors exposed to 4% Vol CO 2, 18% Vol O 2, balance N 2 Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 19 Slide 20 G460 with O2-A3 O 2 sensor response to 4.9% O 2, 18.3% N 2, 76.8% CO 2 Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 20 Slide 21 G460 with O2-A3 (fuel cell) O 2 and IR CO 2 sensors exposed to 94% volume CO 2, balance (6% volume) O 2 Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 21

Slide 22 G460 with O2-A3 (fuel cell) O 2 and IR CO 2 sensors exposed to 94% volume CO 2, balance (6% volume) O 2 Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 22 Slide 23 G460 with 4OX-LL (lead free) O 2 exposed to 94% volume CO 2, balance (6% volume) O 2 Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 23 Slide 24 G460 with 4OX-LL (lead free) O 2, O2-A3 (fuel cell) O 2 and IR CO 2 sensors exposed to 94% volume CO 2, balance (6% volume) O 2 Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 24

Slide 25 O 2 in dry air = 20.95% O 2 at 20 C and 25% RH 20.8% O 2 at 40 C and 85% RH 19.7% O 2 at 40 C and 90% RH 19.5% O 2 at 40 C and 100% RH 19.4% What should you do if the instrument is used in high temp, high RH conditions? Use cylinder of Zero Air to fresh air adjust the O 2 sensor. O 2 concentration in fresh air as function of temperature and humidity Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 25 Slide 26 Measuring combustible gases and vapors Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 26 Slide 27 Flame proof sensors depend on physical barriers such as stainless steel housings and flame arrestors to limit the amount of energy that can ever be released by the sensor The flame arrestor can slow, reduce, or even prevent larger molecules from entering the sensor The larger the molecule, the slower it diffuses through the flame arrestor into the sensor Traditional LEL sensors are Flame proof devices Stainless steel housing Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 27 Flame arrestor (sinter)

Slide 28 Combustible Gas Sensor The catalyst in the LEL sensor bead can be harmed if it is exposed to certain substances Porous Platinum refractory The larger the molecule, the wire coil slower it diffuses into the bead, bead with the longer it takes to be oxidized, catalyst and the lower the relative response 0.1 mm Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 28 Slide 29 Conditions created by oxidation of large molecules affects diffusion of molecules into the sensor Oxidation occurs on step-by-step basis, and proceeds only when molecules are in physical contact with catalyst coated surfaces within the bead. The very hot reaction by-products create convective currents as they rapidly diffuse away from the catalyst surfaces in the bead. Water vapor produced by oxidation of larger molecules creates a significant net outward flux, impeding diffusion of new molecules into the bead. Oxidation of methane: CH 4 + 2O 2 CO 2 + 2H 2O To oxidize one molecule CH 4 three molecules enter bead, and three molecules produced as by-products. Oxidation of pentane: C 5H 12 + 8O 2 5CO 2 + 6H 2O To oxidize one molecule of pentane, nine molecules enter bead, and 11 molecules produced as by-products. Oxidation of nonane: C 9H 20 + 14O 2 9CO 2 + 10H 2O To oxidize one molecule of nonane, 15 molecules enter bead, but 19 need to leave the sensor. Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 29 Slide 30 Typical carbon number distribution in No. 2 Diesel Fuel (liquid) Less than 2% of molecules in diesel vapor are small enough to be measured by means of standard LEL sensor Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 30

Slide 31 Reading % LEL True LEL Concentration Catalytic pellistor combustible gas response curves Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 31 Slide 32 Typical catalytic percent LEL sensor response to 50% LEL methane (2.5% vol. CH 4 ) Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 32 Slide 33 Typical catalytic percent LEL sensor response to 50% LEL pentane (0.7% vol. C 5 H 12 ) Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 33

Slide 34 Catalytic combustible sensor exposed to various gases Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 34 Slide 35 Non-dispersive infrared (NDIR) sensors When infra-red radiation passes through a sensing chamber containing a specific contaminant, only those frequencies that match one of the vibration modes are absorbed The rest of the light is transmitted through the chamber without hindrance The presence of a particular chemical group within a molecule thus gives rise to characteristic absorption bands Non-dispersive IR sensors measure at a specific range of wavelengths associated with a particular gas or class of gases Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 35 Slide 36 I 1 =I 0 *e -αlc L Beer-Lambert Law I 0 is the intensity of the incident light I 1 is the intensity after passing through the material L is the distance that the light travels through the material (the path length) c is the concentration of absorbing species in the material α is the absorption coefficient or the molar Size (length) matters... absorptivity of the absorber Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 36

Slide 37 Must have a COVALENT CHEMICAL BOND O S Linear molecules: SO Energy Absorbed by Bond Stretching and Bending Vibration Symmetric Asymmetric Bend Stretch Stretch Nonlinear Molecules Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 37 Slide 38 Geometry and specific bonds in molecule give rise to IR spectrum Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 38 Slide 39 Lower quantum levels must be populated Dipole moment (degree of charge imbalance) must change with the vibrational motion CO 2 and CH 4 absorb IR Homonuclear diatomics such as hydrogen DO NOT absorb IR IR-transparent gases: H 2 N 2 O 2 F 2 Cl 2 Hg 2 Ar Requirements for IR Absorption Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 39

Slide 40 Wavelengths typically used for IR LEL measurement Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 40 Slide 41 LEL measurement at 3.33μm vs. 3.4μm Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 41 Slide 42 Limitations: Combustible gas NDIR sensor advantages and limitations Molecule must include chemical bonds that absorb at the wavelength(s) used for measurement Not all combustible gases can be detected! Advantages: Diatomic molecules like hydrogen (H 2) cannot be detected at all Gases with double and triple bonds (like acetylene) detect poorly or not at all at some measurement wavelengths NDIR sensors with short optical path-lengths may have limited ability to measure gases with lower relative responses Sensor cannot be poisoned Does not require oxygen to detect gas Can be used for high-range combustible gas measurement Responds well to large hydrocarbon molecules that cannot be measured by means of standard LEL sensor Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 42

Slide 43 Three detection wavelengths Entirely separate optical paths (and pathlengths) for combustible and and CO 2 measurement Light path through three wavelength GfG NDIR sensor Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 43 Slide 44 Be very cautious when using O 2 concentration to estimate concentration of some other displacing gas Every 5% of displacing gas introduced into a confined space reduces O 2 concentration by only about 1% Presence of displacing gas on oxygen concentration Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 44 Slide 45 Shape of raw NDIR CH 4 curve (at 3.33 μm) is less linear than other detectable gases CH 4 curve can be mathematically corrected (normalized) against the response curves of other gases of interest Response of NDIR LEL sensor (3.33 μm, 44 mm path) to various target gases Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 45

Slide 46 Linearized 3.33 μm NDIR combustible gas response curves Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 46 Slide 47 Relative response of pellistor and infrared sensors to n-pentane Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 47 Slide 48 Both sensors were calibrated to 50% LEL n-hexane Readings for both sensors are now very close to the true 50% LEL concentration Initial response of IR sensor is slightly quicker than the pellistor sensor However, the time to the final stable response (T100) is virtually identical for both sensors, (about 150 seconds) Response of calibrated pellistor and IR sensors to 50% LEL n-hexane Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 48

Slide 49 Substance-specific electrochemical sensors Gas diffusing into sensor reacts at surface of the sensing electrode Sensing electrode made to catalyze a specific reaction Use of selective external filters further limits cross sensitivity Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 49 Slide 50 Cross sensitivities of City Technology 4S Rev. 2 sensor at 20 C Relative responses of City Technology 4S Rev. 2 sulfur dioxide (Sh2) sensor at 20 C Gas Concentration used (ppm) Carbon monoxide (Ch) 300 < 1 Reading (ppm Sh2) Nitric oxide (Nh) 50 0 to 5.0 Nitrogen dioxide (Nh2) 6 < 10 Hydrogen sulfide (H2S) 25 < 0.1 Chlorine (Cl2) 5 < 2 Ammonia (NH3) 20 0 Hydrogen (H2) 400 < 1 Hydrogen cyanide (HCN) 10 < 5 Acetylene (C2H2) 10 < 30 Ethene (C2H4) 50 < 45 Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 50 Slide 51 Effects of hydrogen on CO sensor readings Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 51

Slide 52 G460 with 4COSH H 2S, 4HS-LM H 2S and THT (C 4H 8S) sensors exposed to 20 ppm H 2S, balance air Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 52 Slide 53 G460 with 4COSH H 2S, 4HS-LM H 2S and THT (C 4H 8S) sensors exposed to 3.0 ppm tert-butylmercaptan, balance N 2 Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 53 Slide 54 G460 with 4COSH H 2S, 4HS-LM H 2S and THT (C 4H 8S) sensors exposed to 3.0 ppm methylmercaptan, balance N 2 Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 54

Slide 55 Setting toxic sensor alarms Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 55 Slide 56 Exposure limits for H2S Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 56 Slide 57 Where should you set the H 2 S alarms? H 2S TLV only includes STEL and TWA limits; does not include a Ceiling or Peak limit Instruments typically have four user settable alarms for each toxic sensor (Low, High, STEL and TWA) Suggested alarms: NIOSH: Low: 10.0 ppm High: 15.0 ppm STEL: 15.0 ppm TWA: 10.0 ppm TLV : Low: 3.0 ppm High: 5.0 ppm STEL: 5.0 ppm TWA: 1.0 ppm Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 57

Slide 58 What should you do for extended work shifts? Most industrial hygienists use Brief and Scala model Corrects for increased exposure time and decreased recovery time Simple to use Very conservative Adjusted TLV = Where h = # of hours worked per day Model used for chemicals where the TLV is based on acute or chronic toxicity and not for chemicals that have a TLV based on irritation (i.e. Ammonia) For 12 hour shift according to this model the TWA TLV limit should be reduced to one-half the 8-hour value Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 58 Slide 59 Photoionization Detectors Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 59 Slide 60 Catalytic LEL and photoionization detectors are complementary detection techniques Catalytic LEL sensors excellent for measurement of methane, propane, and other common combustible gases NOT detectable by PID PIDs detect large VOC and hydrocarbon molecules that are undetectable by catalytic sensors Best approach to VOC measurement is to use multi-sensor instrument capable of measuring all atmospheric hazards that may be potentially present Catalytic (CC) LEL vs. PID Sensors Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 60

Slide 61 Combustible sensor limitations Contaminant LEL (Vol %) Flashpoint OSHA PEL NIOSH REL TLV 5% LEL in Temp (ºF) PPM Acetone 2.5% -4ºF 1,000 PPM 250 PPM TWA 500 PPM 1250 PPM (-20 ºC) TWA TWA; 750 PPM STEL Diesel (No.2) 0.6% 125ºF None Listed None Listed 15 PPM 300 PPM vapor (51.7ºC) Ethanol 3.3% 55ºF 1,000 PPM 1000 PPM 1000 PPM 1,650 PPM (12.8 ºC) TWA TWA TWA Gasoline 1.3% -50ºF None Listed None Listed 300 PPM 650 PPM (-45.6ºC) TWA; 500 PPM STEL n-hexane 1.1% -7ºF 500 PPM TWA 50 PPM 50 PPM TWA 550 PPM (-21.7 ºC) TWA Isopropyl 2.0% 53ºF 400 PPM 400 PPM 200 PPM 1000 PPM alcohol (11.7ºC) TWA TWA; 500 TWA; 400 PPM STEL PPM STEL Kerosene/ 0.7% 100 162ºF None Listed 100 mg/m3 200 mg/m3 350 PPM Jet Fuels (37.8 72.3ºC ) TWA (approx. TWA (approx. 14.4 PPM) 29 PPM) MEK 1.4% 16ºF 200 PPM 200 PPM 200 PPM 700 PPM (-8.9ºC) TWA TWA; 300 TWA; 300 PPM STEL PPM STEL Turpentine 0.8 95ºF 100 PPM 100 PPM 20 PPM TWA 400 PPM (35ºC) TWA TWA Xylenes (o, m 0.9 1.1% 81 90ºF 100 PPM 100 PPM 100 PPM 450 550 & p Aug isomers) 5, 2015 Best Sensor (27.3 Technologies 32.3 ºC) for TWA Marine Chemistry TWA; Applications 150 TWA; Slide 150 61 PPM PPM STEL STEL Slide 62 Condensation and contamination on lamp window and sensor surfaces can create surface conduction paths between sensing and counter electrodes Buildup of contamination provides nucleation points for condensation, leading to surface currents If present, surface currents cause false readings and / or add significant noise that masks intended measurement (sometimes called moisture leakage ) PID designs MAY require periodic cleaning of the lamp and detector to minimize the effects of contaminants and humidity condensation on PID readings Critical PID Performance Issues: Effects of Humidity and Contamination Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 62 Slide 63 Planar "3D" 2-electrode PID design Benefits: Rapid response and clearing times Limitations: Gap between window and electrodes increases "quenching" effect of water vapor on signal Potential for drawing particulate contaminants into sensor More ionic fragments left behind to be adsorbed onto electrodes and window Results: Increased sensitivity to water vapor and humidity Must clean lamp more frequently Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 63

Slide 64 3-electrode PID Design Benefits: Diffusion design includes "fence electrode" to provide mechanical short circuit between sensing and counter electrodes Electrodes housed in replaceable "stack" Diffusion of molecules into and out of glow zone means less ionic fragments or particulates left behind Limitations: Slightly slower response Operation at higher voltage increases vulnerability to EMI / RFI Results: Reduced "moisture leakage" response due to humidity Clean lamp less frequently Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 64 Slide 65 PID Components Detector assembly Electrodes: sensing, counter and (in some designs) fence Lamp: most commonly 10.6EV, 11.7eV or 9.8 ev Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 65 Slide 66 What are broad-range sensors? Broad-range sensors (like LEL and PID sensors) are non-specific Broad-range sensors provide aggregate measurements for all detectable molecules within a specified class, for instance: Molecules capable of oxidation by standard LEL sensor Molecules capable of ionization by standard PID with 10.6 ev lamp Cannot distinguish between different contaminants they are able to detect Provide single total reading for all detectable substances present PID and LEL readings always relative to gas used to calibrate detector Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 66

Slide 67 The Controlling Compound Every mixture of gases and vapors has a compound that is the most toxic and controls the setpoint for the whole mixture Determine that chemical and you can determine a conservative mixture setpoint If we are safe for the worst chemical we will be safe for all chemicals Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 67 PID Alarms: Varying Mixtures Slide 68 Chemical Name 10.6eV CF Ethanol appears to be the safest compound Turpentine appears to be the most toxic NIOSH REL Exposure Limit (8-hr. TWA) Ethanol 10.0 1000 Turpentine 0.45 100 Acetone 1.2 250 This table only provides half of the decision making equation Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 68 PID Alarms: Varying Mixtures Slide 69 Set the PID for the compound with the lowest Exposure Limit (EL) in equivalent units and you are safe for all of the chemicals in the mixture Divide the EL in chemical units by CF to get the EL in isobutylene EL Isobutylene = EL chemical CF chemical PID Alarms: Varying Mixtures Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 69

Slide 70 Chemical name CF iso (10.6eV) NIOSH REL (8 hr. TWA) EL ISO (PEL) TLV IF you are following the NIOSH REL then ethanol is the controlling compound when the exposure limits are expressed in equivalent Isobutylene Units The equivalent ELiso is a calculation that involves a manufacturer specific Correction Factor (CF) Similar calculations can be done for any PID brand that has a published CF list PID Alarms: Varying Mixtures (8hr. TWA) BE CAREFUL: If you are following the TLV the controlling chemical would be turpentine! Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 70 EL ISO (TLV) Ethanol 10.0 1000 100.0 1000 100.0 Turpentine 0.45 100 222.3 20 44.5 Acetone 1.2 250 208.4 500 416.7 Slide 71 Choosing the best sensor configuration GfG multi-sensor instruments can include up to seven channels of realtime measurement Available sensors for combustible gas and VOC measurement: CC %LEL IR %LEL IR %Vol Electrochemical toxic PID Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 71 Slide 72 Selection matrix for Sensors for measurement of combustible gas and VOCs Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 72

Slide 73 Questions? Aug 5, 2015 Best Sensor Technologies for Marine Chemistry Applications Slide 73