Thermo Scientific Dionex IonPac AS25 Anion-Exchange Column. Minutes

Similar documents
Thermo Scientific. Anion-Exchange Column

Thermo Scientific Dionex IonPac AS23 Anion-Exchange Column

columns IonPac AS22 Anion-Exchange Column

columns IonPac AS17-C Anion Exchange Column

Dionex IonPac AS28-Fast-4µm column

columns IonPac AS18 Anion-Exchange Columns

Thermo Scientific. Anion-Exchange Column. Determination of Inorganic Anions in Diverse Sample Matrices. Superior Chromatographic Performance

Thermo Scientific Dionex IonPac AS24A Anion-Exchange Column

anion-exchange column

Thermo Scientific Dionex IonPac AS26 Anion-Exchange Column

Thermo Scientific Dionex IonPac AS11-HC-4µm Anion-Exchange Column

Superior Chromatographic Performance Recommended anion-exchange column for separation of haloacetic acids prior to MS or MS/MS detection

New On-Line High-Pressure Electrolytic Eluent Generators for Ion Chromatography

Thermo Scientific Dionex IonPac AS11 and AS11-HC Anion-Exchange Column

Thermo Scientific Dionex Ion Chromatography Solutions. Global water safety. bromate analysis in drinking water

High-Pressure Electrolytic Carbonate Eluent Generation Devices and Their Applications in Ion Chromatography Systems

columns I o n P a c AS11 and AS11-H C Anion-E x c h a n g e C o l u m n s

Determination of Tetrafluoroborate, Perchlorate, and Hexafluorophosphate in a Simulated Electrolyte Sample from Lithium Ion Battery Production

Separation of heat stable amine salts in methyldiethanolamine (MDEA) solutions using high-pressure IC

columns IonPac SCS 1 Silica Cation Separator

Thermo Scientific Dionex IonPac CS17 Cation-Exchange Column

Efficient Separations Obtained by Using Smaller Particle Size Analytical Columns with a High-Pressure Ion Chromatography System

Determination of trace anions in concentrated hydrofluoric acid

New Developments in Capillary Ion Chromatography using 4 μm Columns and Charge Detection

Keywords Haloacetic acids, Water analysis, 2-D ion chromatography, ICS-3000

Concentrator and Trap Columns. Column: IonPac AG15, AS15, 2 mm. Eluent Source: EG40 Concentrator. Temperature: 30 C Column: IonPac AC15 (2 50 mm)

Determination of Cations and Amines in Hydrogen Peroxide by Ion Chromatography Using a RFIC (Reagent-Free) System

Determinations of Inorganic Anions and Organic Acids in Beverages Using Suppressed Conductivity and Charge Detection

Quantification of Trace and Major Anions in Water by Ion Chromatography in a High-Throughput Laboratory

Time Savings and Improved Reproducibility of Nitrate and Nitrite Ion Chromatography Determination in Milk Samples

Determination of Tartaric Acid in Tolterodine Tartrate Drug Products by IC with Suppressed Conductivity Detection

Using a Reagent-Free ion chromatography system to monitor trace anion contamination in the extracts of electronic components

For new orders of the following parts discussed in this manual, please use the updated part numbers listed below.

For new orders of the following parts discussed in this manual, please use the updated part numbers listed below.

Utility of the Charge Detector in Ion Chromatography Applications

Accurate and Reproducible Determination of Organic Halogens Using Combustion Ion Chromatography

for IonPac AG11-HC IonPac AS11-HC

Inline sample preparation for the determination of anions in sodium hydroxide

Determination of Bromate in Bottled Mineral Water Using the CRD 300 Carbonate Removal Device

Determination of Trace Cations in Power Plant Waters Containing Morpholine

suppressors Eluent Suppressors for Ion Chromatography

Determination of Adsorbable Organic Halogen in Wastewater

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules

Thermo Scientific Dionex eluent suppressors for ion chromatography

High-Performance Chromatography Superior isocratic separation of

Overcoming Challenging Matrices in Ion Chromatography

Direct Determination of Small Organic Acids in Sea Water by IC-MS

Determination of Inorganic Anions in Drinking Water by Ion Chromatography

Determination of Trace Anions in Concentrated Bases Using AutoNeutralization Pretreatment and Ion Chromatography

Determination of Sulfate and Chloride in Ethanol by Ion Chromatography

IonPac Trace Cation Concentrator

Determination of Verapamil Hydrochloride Purity Using the Acclaim PA Column

Determination of Silicate in High Purity Water Using Ion Chromatography and AutoPrep

The Determination of Trace Anions in Concentrated Phosphoric Acid

Determination of Trace Anions in Organic Solvents

Expanded capabilities in ammonium and amine detection

The determination of trace anions in concentrated phosphoric acid

Determination of Organic Acids in Beer Samples Using a High-Pressure Ion Chromatography System

Sample Preparation for Ion Chromatography

Application of Eluent Generation for Trace Anion Analysis of Borated Waters

Determinations of Heat Stable Amine Salts and Amines in Amine Scrubbing Solutions Using Suppressed Conductivity and Charge Detection

Trace Level Determination of Bromate in Ozonated Drinking Water Using Ion Chromatography

Determination of Inorganic Anions in Wastewater by Ion Chromatography

Application Note 187. Brian DeBorba and Jeff Rohrer Thermo Scientific, Sunnyvale, CA, USA

suppressors SRS -ULTRA Self-Regenerating Suppressor

Development of the Thermo Scientific Dionex IonPac AS26 Column for Haloacetic Acid Analysis

4. Ion chromatography (IC) 4.1. Educational aims and objectives

Anion and Cation analysis with Professional IC - automatic dilution and sample preparation with SPM

PRODUCT MANUAL. OMNIPAC PAX-100 GUARD COLUMN (4 x 50 mm, P/N ) OMNIPAC PAX-500 GUARD COLUMN (4 x 50 mm, P/N )

Determination of Common Inorganic Anions in Environmental Waters Using a Hydroxide Selective Column

Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry

Determination of Organic Acids and Inorganic Anions in Lithium-Containing Boric Acid-Treated Nuclear Power Plant Waters

Determination of Methylamine in Drug Products

Determination of the Composition of Natural Products by HPLC with Charged Aerosol Detection. Introduction. Black Cohosh. Corona Detector Parameters

The power to increase productivity. Thermo Scientific Dionex Reagent-Free Ion Chromatography (RFIC) System Capabilities

Determination of trace anions in high-purity waters by high volume/direct injection ion chromatography

Determination of trace anions in basic solutions by single pass AutoNeutralization and ion chromatography

Accurate and Precise Automated Dilution and In-line Conductivity Measurement Using the AS-AP Autosampler Prior to Analysis by Ion Chromatography

Ion Chromatography: Green Chemistry for a Green Environment. Ken Kirkbride Somerset, New Jersey October 12, 2011

Determination of trace anions in high-nitrate matrices by ion chromatography

Cation Exchange HPLC Columns

Determination of Trace Anions in Concentrated Hydrofluoric Acid

Determination of trace anions in organic solvents using matrix elimination and preconcentration

User Manual. IonPac NS2 Columns Revision 02 October For Research Use Only. Not for use in diagnostic procedures.

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography

ION CHROMATOGRAPHY SYSTEM S 150

PRODUCT MANUAL OMNIPAC PCX-500 GUARD COLUMN (PCX-500 GUARD, P/N ) OMNIPAC PCX-500 ANALYTICAL COLUMN (PCX-500 ANALYTICAL, P/N )

Determination of Monochloroacetic Acid in Carbocisteine

Automating Method Development with an HPLC System Optimized for Scouting of Columns and Eluents

Determination of an anionic fluorochemical surfactant in a semiconductor etch bath

[ Care and Use Manual ]

ProPac WCX-10 Columns

INSTALLATION INSTRUCTIONS and TROUBLESHOOTING GUIDE. for the OnGuard- CARTRIDGE

groups I and II cations, amines, divalent transition metals

Determination of trace anions in concentrated glycolic acid

Determination of trace concentrations of oxyhalides and bromide in municipal and bottled waters

New Stationary Phases for Solid-Phase Extraction. Pranathi R. Perati, Rosanne Slingsby, and Carl Fisher Thermo Fisher Scientific, Sunnyvale, CA, USA

Determination of Trace Anions in Concentrated Glycolic Acid

Easy Method Transfer from HPLC to RSLC with the Dionex Method Speed-Up Calculator

Advances in Sample Preparation for Accelerated Solvent Extraction

Transcription:

columns Thermo Scientific Dionex IonPac AS Anion-Exchange Column Isocratic Separation of Sulfur Species and Inorganic Anions Using the Dionex IonPac AS Column. Fluoride. Bromate. Chloride. Nitrite. Bromide. Nitrate. Carbonate. Sulfite. Sulfate. Iodide. Thiocyanate. Perchlorate. Thiosulfate The Thermo Scientific Dionex IonPac AS is a high-capacity, hydroxide-selective, anion-exchange column optimized for the separation of multivalent anions and polarizable anions (perchlorate), including sulfur speciation (sulfite, sulfate, thiocyanate and thiosulfate). Using an isocratic hydroxide eluent, these analytes can be determined in approximately minutes without the use of solvent. The Dionex IonPac AS is ideal for the determination of sulfur species in wastewater effluents from industrial, chemical and petrochemical industries as well as food and beverage samples. The Dionex IonPac AS column is available in., mm, and mm formats, supporting flow rates from. to ml/min. Recommended for Multivalent Anions in Diverse Sample Matrices Municipal wastewater Food processing samples Paper and pulp effluents Refinery waste products Industrial wastewaters Industrial scrubber solutions Geothermal power plant samples Superior Chromatographic Performance Optimized hydrophilic resin for the gradient separation of multivalent anions and polarizable anions. Recommended for sulfur speciation in process effluents, wastewater and scrubber solutions. Use with an eluent generator for simplified Thermo Scientific Dionex Reagent-Free Ion Chromatography (RFIC ) system operation. Requires only a deionized water source to produce hydroxide eluent. Eluent suppression using the Thermo Scientific Dionex ASRS Anion Self-Regenerating Suppressor or the Thermo Scientific Dionex ACES Anion Capillary Electrolytic Suppressor, provides RFIC system operation with low backgrounds and enhanced analyte sensitivity. High capacity: µeq per column ( mm column). Compatible with organic solvents to enhance analyte solubility, modify column selectivity, and effectively clean the column. The capillary and microbore formats require less eluent consumption, thereby reducing operating costs.

High-Efficiency Particle Structure The Dionex IonPac AS column was developed using a unique polymer bonding technology. The stationary phase consists of a novel, hyperbranched, anion-exchange condensation polymer electrostatically attached to the surface of a wide-pore polymeric substrate. The substrate is surface-sulfonated in exactly the same manner as Dionex latex-coated, anion-exchange materials. However, in this anion-exchange resin, alternating treatments of epoxy monomer and amines produce a coating that grows directly off the substrate surface, as illustrated in Figure. Resin capacity is controlled through the number of alternating coating cycles. The resulting polymer is extremely hydrophilic and, therefore, has excellent selectivity for hydroxide eluents, allowing the use of lower eluent concentrations. The Dionex IonPac AS column uses a high-capacity resin with optimized selectivity for sulfur speciation in complex matrices. Isocratic Separation of Multivalent and Polarizable Anions Sulfur-containing inorganic anions are commonly encountered in soil sediments, hot springs, and lake waters. They are also frequently encountered in many industrial settings, such as the monitoring of process liquors and wastewaters from paper mills, mining sites, off-shore oil drilling operations, and alkaline scrubber solutions, and in the analysis of foods and beverages. Due to their redox chemistry, many sulfur-containing species can readily react with each other, decompose over time, or be oxidized in the presence of air. They are also very sensitive to the solution ph, which would affect the distribution of the species over time. All these make the determination of the sulfur-containing species a very challenging task. Figure. Structure of a Dionex IonPac AS packing particle. Conceptual illustration of surface modification Column: Dionex IonPac AS, mm Eluent: mm KOH Flow Rate: ml/min Inj. Volume: µl Temperature: C Dionex ASRS, mm, AutoSuppression, recycle mode Figure. Isocratic separation of sulfur species and inorganic anions using a hydroxide eluent on the mm Dionex IonPac AS column. The Dionex IonPac AS column has been optimized for the fast, isocratic determination of multivalent and polarizable anions such as thiosulfate, iodide, thiocyanate, and perchlorate in less than minutes without the use of solvent, as shown in Figure.. Fluoride. Bromate. Chloride. Nitrite. Bromide. Nitrate. Carbonate. Sulfite. Sulfate. Iodide. Thiocyanate. Perchlorate. Thiosulfate For the best peak shape of polarizable anions, including perchlorate, the Dionex IonPac AS or the Dionex IonPac AS columns are recommended.

Gradient Separations as Simple as Isocratic Runs with Eluent Generation An eluent generator produces high purity potassium hydroxide eluent electrolytically from water, eliminating the need for eluent preparation. The hydroxide eluent produced is free of carbonate contamination. The use of carbonate-free hydroxide eluents results in minimal baseline shifts during hydroxide gradients yielding lower background conductivities and lower detection limits for target analytes. Figure shows the separation of common anions and polarizable anions using the Dionex IonPac AS mm column and gradient elution. No solvent is required to achieve the separation of these highly polarizable anions in less than minutes. Column: Dionex IonPac AG, AS, mm Eluent: Potassium Hydroxide: mm from to min, mm from to min, mm from to min Flow Rate: ml/min Inj. Volume: µl Temperature: C Dionex ASRS, mm,. Fluoride. Bromide. Acetate. Iodide. Formate. Sulfate. Chloride. Thiocyanate. Nitrite. Thiosulfate. Chlorate. Chromate. Nitrate. Phosphate Figure. Separation of common anions and polarizable anions using the Dionex IonPac AS column with gradient elution. Fast Analysis Using the Dionex IonPac AS The Dionex IonPac AS column is a high capacity column, µeq/column for the mm column, which allows for the analysis of complex sample matrices and generally produces longer run times. However, by increasing the flow rate, polarizable anions can be resolved isocratically in less than minutes as shown in Figure...... Flow rate:. ml/min Flow rate:. ml/min Flow rate:. ml/min Column: Dionex IonPac AG, AS, mm Eluent: mm KOH Flow Rate: See chromatogram Inj. Volume: µl Temperature: C Dionex ASRS, mm,. Fluoride mg/l. Chloride. Sulfate. Thiosulfate. Iodide. Thiocyanate. Figure. Fast analysis using the Dionex IonPac AS column with increased flow rates.

Dionex IonPac AS Capillary Format The Dionex IonPac AS capillary column (. mm) is packed with the same material as the equivalent analytical scale version, thus producing the same performance as a mm column, but requires only / th the eluent flow rate. The capillary format offers the advantages of less eluent consumption, providing reduced eluent costs and the ability to operate your system in the Always On, Always Ready mode. Figure illustrates the separation of anions using the Dionex IonPac AS capillary column. Excellent retention time reproducibility can be achieved using the capillary format.. Column: Dionex IonPac AS,. mm Eluent: mm KOH Eluent Source: Dionex EGC-KOH Capillary Flow Rate: µl/min Inj. Volume:. µl Temperature: C Dionex ACES, Figure. Analysis of polarizable anions using the Dionex IonPac AS capillary column.. Fluoride. Chloride. Carbonate. Sulfate. Iodide. Thiocyanate. Thiosulfate Determination of Sulfur Species in Wastewater Samples The high capacity of the Dionex IonPac AS column makes it ideal for the analysis of sulfur species in wastewater samples. Figure shows the analysis of a wastewater sample containing common anions, including phosphate, with a run time of less than minutes. The column produces excellent resolution of carbonate from sulfate. The Sample B chromatogram in Figure shows the wastewater spiked with sulfite and thiosulfate. With an optimized hydroxide gradient, these species can easily be determined in less than minutes. Sample A Sample B Column: Dionex IonPac AG, AS, mm Eluent: Potassium hydroxide: mm from to. min, mm from. to min, mm from to min, mm from to min Flow Rate: ml/min Inj. Volume: µl Temperature: C Dionex ASRS, mm, AutoSuppression, recycle mode Sample A: Wastewater Sample B: Wastewater spiked with sulfite and thiosulfate. Fluoride. Chloride. Nitrate. Carbonate. Sulfite. Sulfate. Thiosulfate. Phosphate Figure. Determination of inorganic anions and sulfur species in wastewater samples using the Dionex IonPac AS column.

Analysis of Gas Scrubber Solutions Acid gases such as hydrochloric acid (HCl), hydrofluoric acid (HF), phosgene (COCl ), chlorine (Cl ), and hydrogen sulfide (H S) are removed from caustic scrubbers in industrial processes. The purpose of the caustic scrubber is to prevent exposure of the acid gases to the environment. Effectiveness of these scrubbers are established by frequent analysis. Figure shows the application of the analysis of a simulated acid-gas scrubber sample consisting of % base. The sample was diluted -fold in the above application. For higher concentration of scrubber solutions, a Thermo Scientific Dionex ASRN neutralizer can be used to neutralize the alkaline samples. Analysis of Volcanic Gas Samples Gases that are released from volcanic vents are collected and analyzed for sulfur-containing species and polarizable anions. The gases are collected in a concentrated sodium hydroxide solution having high levels of carbonate and sulfate present. Figure shows the analysis of a simulated sample of volcanic gas condensate on the Dionex IonPac AS column. The sample was spiked with fluoride, chloride, bromide, sulfite, iodide, thiocyanate, thiosulfate and phosphate, which are eluted isocratically in approximately minutes. Column: Dionex IonPac AG, AS, mm Eluent: Potassium Hydroxide: mm from to min, mm from to min, mm from to min Flow Rate:. ml/min Inj. Volume: µl Temperature: C Dionex ASRS, mm, Sample: % base diluted -fold Figure. Sulfur species analysis of a simulated acid-gas scrubber solution using the Dionex IonPac AS column.. Chloride. Carbonate. Sulfate Column: Dionex IonPac AG, AS, mm Eluent: mm KOH Cartridge Flow Rate:. ml/min Inj. Volume: µl Temperature: C Dionex ASRS, mm,. Unknown. Sulfite. Fluoride. Sulfate. Unknown. Iodide. Chloride. Thiocyanate. Bromide. Thiosulfate. Carbonate. Phosphate Figure. Simulated sample of volcanic gas condensate separated using the Dionex IonPac AS column.

System Recommendations The Dionex IonPac AS column is recommended for use with the Thermo Scientific Dionex ICS- or ICS- RFIC systems equipped with an eluent generator. The Dionex Ion- Pac AS can also be used with older Dionex IC systems equipped with an eluent generator or an RFC- Reagent- Free Controller. The eluent generator is used to automatically produce potassium hydroxide gradients from deionized water. Suppressor Recommendations For optimum ease-of-use and performance, the Dionex IonPac AS column should be used with the Dionex ASRS or Dionex ACES supressors. Operate the Dionex IonPac AS column at an elevated temperature ( C) to ensure reproducible retention times. Anion Trap Columns When using an eluent generator for eluent delivery, a Thermo Scientific Dionex CR-ATC Continuously Regenerated Anion Trap Column should be installed between the eluent generator cartridge and the degas module. As an alternative for mm and mm systems, a Thermo Scientific Dionex ATC-HC column can be installed between the pump outlet and inlet of the eluent generator cartridge. Alternatively, when using a manually prepared sodium hydroxide gradient with the Dionex IonPac AS, the Thermo Scientific Dionex ATC- Anion Trap Column should be installed between the gradient pump and the injection valve to remove anionic contaminants from the eluent. Concentrator Columns For concentrator work with a mm or mm Dionex IonPac AS column, use the: Dionex IonPac AG guard column; Thermo Scientific Dionex Ultra Trace Anion Concentrator Column (UTAC-ULP, UTAC XLP, UTAC-ULP, or UTAC-XLP); or Thermo Scientific Dionex Trace Anion Concentrator Column (TAC-ULP) when a single-piston pump, e.g., the Thermo Scientific Dionex AXP pump (pulse damper required), is used for sample delivery. In addition to the concentrator columns listed above, use the Thermo Scientific Dionex UTAC- LP, UTAC-LP or TAC-LP when the sample is delivered with a syringe or with a low-pressure autosampler, e.g., the Thermo Scientific Dionex AS-DV. For concentrator work with a. mm capillary column, use the Dionex IonPac AG capillary guard column or the Thermo Scientific Dionex IonSwift MAC- concentrator column.

Specifications Dimensions: Dionex IonPac AS Analytical Column: mm and mm Dionex IonPac AG Guard Column: mm and mm Dionex IonPac AS Capillary Column:. mm Dionex IonPac AG Capillary Guard Column:. mm Maximum Operating Pressure: psi (Standard and Microbore) psi (Capillary) Mobile Phase Compatibility: ph ; % HPLC solvents Substrate Characteristics: Analytical Column: Supermacroporous Resin Bead Diameter (µm):. Pore Size: Å Cross-Linking (%DVB): % Guard Column: Microporous Resin Bead Diameter (µm):. Pore Size: < Å Cross-Linking (%DVB): % Ion Exchange Group: Functional Group: Alkanol quaternary ammonium ion Hydrophobicity: Ultralow Capacity:. µeq ( mm). µeq* ( mm) µeq ( mm). µeq* ( mm). µeq (. mm). µeq* (. mm) *Guards are packed with a lowcapacity microporous resin. Column Construction: PEEK with threaded ferrule-style end fittings. All components are nonmetallic. Ordering Information To order in the U.S., call () - or contact the Dionex Products Regional Office nearest you. Outside the U.S., order through your local Dionex Products office or distributor. Refer to the following part numbers. Analytical and Guard Columns.Part Number Dionex IonPac AS Capillary Column (. mm)... Dionex IonPac AG Capillary Guard Column (. mm)... Dionex IonPac AS Analytical Column ( mm)... Dionex IonPac AG Guard Column ( mm)... Dionex IonPac AS Analytical Column ( mm)... Dionex IonPac AG Guard Column ( mm)... Trap Columns. Dionex CR-ATC Continuously Regenerated Anion Trap Column... (for use with systems equipped with an eluent generator or the Dionex RFC- Reagent-Free Controller) Dionex CR-ATC Continuously Regenerated Anion Trap... Column (Capillary) (for use with Capillary Anion Columns) Dionex ATC- Anion Trap Column ( mm)... (for use with mm columns) Dionex ATC- Anion Trap Column ( mm)... (for use with mm columns) Dionex ATC-HC Anion Trap Column...... (for use with an eluent generator) Trace Anion Concentrator Columns. Dionex MAC- Monolith Anion Concentrator Column (. mm). Dionex TAC-LP Trace Anion Concentrator ( mm)... Dionex TAC-ULP Trace Anion Concentrator ( mm)... Dionex UTAC-LP Ultra Trace Anion Concentrator... Low Pressure ( mm) Dionex UTAC-ULP Ultra Trace Anion Concentrator... Ultra Low Pressure ( mm) Dionex UTAC-XLP Ultra Trace Anion Concentrator... Extremely Low Pressure ( mm) Dionex UTAC-LP Ultra Trace Anion Concentrator... Low Pressure ( mm) Dionex UTAC-ULP Ultra Trace Anion Concentrator Ultra Low Pressure ( mm)... Dionex UTAC-XLP Ultra Trace Anion Concentrator Extremely Low Pressure ( mm)... PEEK is a trademark of Victrex, PLC. All other trademarks are the property of Thermo Fisher Scientific Inc and its subsidiaries. Speed Simplicity Solutions Dionex Products Titan Way P.O. Box north America U.S./ Canada () - Europe Austria () Benelux () ; () Denmark () France () Germany () Asia Pacific Australia () China () India () Japan () Korea () Singapore () Sunnyvale, CA Ireland () Italy () Sweden () Taiwan () South America - Switzerland () United Kingdom () Brazil () www.thermoscientific.com/dionex () - LPN - PDF / Thermo Fisher Scientific Inc.