Obstruction of trabecular orifices in primary open-angle glaucoma

Similar documents
ENDOTHELIAL CELL VACUOLATION IN THE CORNEA*

Human Trabecular Meshwork Phagocytosis

The Integration of the Corneal and Limbal Fibrils in the Human Eye

Human trabecular cells. I. Establishment in tissue culture and growth characteristics

Human Trabecular Meshwork Cell Survival Is Dependent on Perfusion Rate

Numerical solution of ocular fluid dynamics

Short-Pulsed Neodymium-YAG Laser Trabeculotomy

ANTERIOR SEGMENT OPTICAL

NUMERICAL SIMULATION OF AQUEOUS HUMOR FLOW: FROM HEALTHY TO PATHOLOGIC SITUATIONS J.A. FERREIRA, P. DE OLIVEIRA, P. M. DA SILVA AND J.N.

MODELING THE FLOW OF AQUEOUS HUMOR IN POSTERIOR CHAMBER. Ram Avtar, Swati Srivastava 1

Morphology of the Trobeculor Meshwork and Inner- Wall Endothelium After Cationized Ferritin Perfusion in the Monkey Eye

Functional and electron microscopic changes in the trabecular meshwork remaining after trabeculectomy in cynomolgus monkeys

Numerical Solution of Ocular Fluid Dynamics in a Rabbit Eye: Parametric Effects

Distributions of 35 S-sulfote and 3 H-glucosomine in the Angular Region of the Hamster: Light and Electron Microscopic Autoradiography

Ultrastructural changes in moist chamber corneas. E. M. Schaeffer"

Mechanical Analysis of Rat Trabecular Meshwork

Influence of Mercurial Sulfhydryl Agents on Aqueous Outflow Pathways in Enucleated Eyes

COMMUNICATIONS. OPEN-ANGLE GLAUCOMA*t PATHOLOGY OF TRABECULAR NERVES IN. (Wolter, 1959). As long as not even the normal functions of the trabecular

The Cytoskeleton of the Cultured Human Trabecular Cell

Quantitative Analysis of the Effect of Optical Probe Positioning on the Measurements of Flattened Diameter of Ocular Cornea for Applanation Tonometry

2 Roles of Corneal Epithelial Ion Transport Mechanisms in Mediating Responses to Cytokines and Osmotic Stress

Iris Biomechanics in Health and Disease

Ulfrasfrucfural Changes of Human Trabecular Meshwork After Phofocoagulation With a Diode Laser

3D FEM temperature distribution analysis of the human eye exposed to laser radiation

Microfilaments in the cells of the human trabecular meshwork

Descemet stripping endothelial keratoplasty (DSEK) 1 3

Thermal modelling of the human eye exposed to infrared radiation of 1064 nm Nd:YAG and 2090 nm Ho:YAG lasers

Flow in the anterior chamber of the eye with an implanted iris-fixated artificial lens

Multiple patterns of angle closure mechanisms in primary angle closure glaucoma in Chinese

University of Southampton Research Repository eprints Soton

Fluid Mechanics of the Descemet Membrane Detachment with Spontaneous Reattachment

Characterization of /?-Adrenergic Receptors in Cultured Human Trabecular Cells and in Human Trabecular Meshwork

An electrical model of the human eye

THE USE OF ULTRASOUND IN OCULAR BIOMETRY

Implant Design for Ophthalmic Delivery: The place of materials and fabrication methods

Human Anatomy & Physiology

Numerical Simulations of Fluid Pressure in the Human Eye

Reports 677 REFERENCES. Origin of ghost cell in Coats' disease.

Comparison of ocular response analyzer, dynamic contour tonometer and Goldmann applanation tonometer

Phakic iris-fixated intraocular lens placement in the anterior chamber: effects on aqueous flow

Estimating human trabecular meshwork stiffness by numerical modeling and advanced OCT imaging

A comparative study of Bowman s layer in some mammals: Relationships with other constituent corneal structures

The Cytoskeleton of the Cynomolgus Monkey Trabecular Cell

Fluid Mechanics of the Eye

Experimental research on intraocular aqueous flow by PIV method

Steady State Heat Analysis of the Eye Using Finite Element Method

Reports. Table I. Identification of specimen studied. Ultrastructural description of a "cylinder organelle" in the outer plexiform layer

X-ray Photoelectron Spectroscopy/ Electron spectroscopy for chemical analysis (ESCA), By Francis Chindeka

Dynamic secondary electron emission in dielectric/conductor mixed

I n previous communications 1 ' 2 a model

An Introduction to Anatomy

CLINICAL SCIENCES. reported significant differences between thickness estimates from healthy and glaucomatous eyes Although promising as

EFFECTS OF SCLERAL STIFFNESS ON BIOMECHANICS OF THE OPTIC NERVE HEAD IN GLAUCOMA

ENERGY DISPERSIVE X-RAY ANALYSIS OF HUMAN HAIR Mohd Abdul Mujeeb 1 and Kahlid M Zafar 2

This article appeared in a journal published by Elsevier. The attached copy is furnished to the author for internal non-commercial research and

Effect of tear additives on the shear stress and normal stress acting on the ocular surface

Tokuhiro JSHIHARA, Chotatsu TSUKAYAMA, Fumiya UCHINO

The Excimer Laser and Applications to Corneal Ablative Surgery

DISTENSIBI:LITY OF THE HUMAN EYE*

Thermal Modelling of the Human Eye Exposed to Laser Radiation

MSE 321 Structural Characterization

Biology 1, Philippine Science High School-Main Campus Laboratory Activity # 2: PLANT AND ANIMAL TISSUES

Electron Beam Curable Varnishes. Rapid Processing of Planarization Layers on Polymer Webs

Formulation and Ocular Bioavailability of Certain Drugs from Ophthalmic Preparations

Anterior eye development and ocular mesenchyme: new insights from mouse models and human diseases

University of Pécs Institute of Pharmaceutical Technology and Biopharmacy

Thin-Film Coupled Fluid-Solid Analysis of Flow Through the Ahmed Glaucoma Drainage Device

Modern Optical Spectroscopy

The Accuracy of Tower' Maps to Display Curvature Data in Corneal Topography Systems

Mathematical Modeling of the Biomechanics of the Lamina Cribrosa Under Elevated Intraocular Pressures

Fluid and structure coupling analysis of the interaction between aqueous humor and iris

Cells to Tissues. Peter Takizawa Department of Cell Biology

A New Photogrammetric Method for Quantifying Corneal Topography

Chemical Incidents. How to manage them before they become an accident?

Relation Between Superficial Capillaries and Foveal Structures in the Human Retina

University of Genoa. PhD program in Civil, Chemical and Environmental Engineering Fluid Dynamics and Environmental Engineering. Cycle XXX.

Imaging Methods: Scanning Force Microscopy (SFM / AFM)

Partial Contact Indentation Tonometry for Measurement of Corneal Properties-Independent Intraocular Pressure

A recyclable supramolecular membrane for size-selective separation of nanoparticles

Computer-based analysis of rhegmatogenous retinal detachment

Jaemin Kim, Xi Yin, Kai-Chieh Tsao, Shaohua Fang and Hong Yang *

Gaetano L Episcopo. Scanning Electron Microscopy Focus Ion Beam and. Pulsed Plasma Deposition

LECTURE 1: ELECTROMAGNETIC RADIATION

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

Basic Principles Brief history of EM

Structure and Function of Plant and Animal Cells

Developmental Zoology. Ectodermal derivatives (ZOO ) Developmental Stages. Developmental Stages

Predicting Primary Implant Stability Using the Trabecular Bone Score

Morphology and Ultrastructure of Staphylococcal L Colonies: Light, Scanning,

Theory vs Conspiracy Theory

2014 ASCRS Course Phaco Prechop Takayuki Akahoshi, MD

International Journal of Computing and Business Research (IJCBR) ISSN (Online) : APPLICATION OF GIS IN HEALTHCARE MANAGEMENT

MEDLINE Clinical Laboratory Sciences Journals

Supplementary Information

Supporting Information. Controlled mineralization by extracellular matrix: monodisperse, colloidal stable calcium phosphate-hyaluronan

BATHING WITH SOLUTIONS OF DIFFERING

(From The Rockefeller Institute for Medical Research)

Electrochemically-assisted self-assembly of mesoporous silica thin films SUPPLEMENTARY INFORMATION A. WALCARIUS, E. SIBOTTIER, M. ETIENNE, J.

ABC s of Electrochemistry series Materials Characterization techniques: SEM and EDS Ana María Valenzuela-Muñiz November 3, 2011

16. Why are many anatomical terms based on Greek and Latin roots? A. because they are easy to spell B. because many terms are based on the names of

Transcription:

Obstruction of trabecular orifices in primary open-angle glaucoma Eur J Anat, 6 (2): 75-81 (2002) J.M. Potau, M. Canals, J. Costa, M.D. Merindano and D. Ruano Ocular Morphology Unit, Department of Human Anatomy, Faculty of Medicine, University of Barcelona, 08036 Barcelona, Spain SUMMARY The morphologic and structural changes undergone by the trabecular meshwork have frequently been related to the development of primary open-angle glaucoma, which consists of a sustained increase in intraocular pressure due to the accumulation of aqueous humour in the anterior chamber of the eye. The aqueous humour leaves the anterior chamber of the eye, passing through the trabecular orifices to Schlemm's canal. Accordingly, the anatomic integrity of the trabecular meshwork is necessary to guarantee correct aqueous drainage and the maintenence of adequate intraocular pressure. In the present study, the three-dimensional morphology of glaucomatous trabecular meshworks was studied with a view to observing morphological changes possibly related to the development of primary open angle-glaucoma. Key Words : Trabecular meshwork Ultrastructure Scanning electron microscopy Primary open-angle glaucoma INTRODUCTION The drainage of aqueous humour from the anterior chamber of the eye mainly occurs through Schlemm s canal. Before entering this structure, the aqueous humour must first pass through the trabecular meshwork. The trabecular meshwork is an important anatomic structure located at the iridosclerocorneal angle of the eye. It consists of several layers of trabecular beams that delimit a complex system of orifices through which the aqueous humour drains from the anterior chamber of the eye to Schlemm s canal. The trabecular meshwork has classically been divided into two parts: an internal, lax uveal meshwork and an external, compact corneoscleral meshwork. The uveal meshwork consist of 3 or 4 layers of 5 to 12 µm-thick uveal beams, which have a characteristic cylindrical morphology and a rough surface. They are arranged perpendicular to the peripheral limit of the cornea and delimit polygonal uveal orifices that are 20 to 30 µm in diameter. The corneoscleral meshwork is located closer to Schlemm's canal. It consists of 15 to 20 layers of corneoscleral beams, each of them 5 µm-thick. The corneoscleral beams have a smooth and flat shape and are oriented in parallel to the periphery of the cornea. Oval-shaped orifices with a 10 µm-wide maximum axis and a 5 µm-wide minimum axis are delimited by the corneoscleral beams. The location and morphological features of the trabecular meshwork have led many authors to believe that alterations in their shape and size may alter normal drainage of the aqueous humour. This would lead to an accumulation of the aqueous humour in the anterior chamber of the eye, with a subsequent increase in intraocular pressure. Thus, anomalous trabecular meshworks have consistently been related to different types of glaucoma, the most frequent being the primary open-angle type. In the present study we compared the morphology of non-glaucomatous and glaucomatous trabecular meshworks in order to observe morphological and structural changes possibly related to the development of primary open-angle glaucoma. Submitted: March 5, 2002 Accepted: June 10, 2002 Correspondence to: Dr. J.M. Potau. Ocular Morphology Unit, Department of Human Anatomy, Faculty of Medicine, University of Barcelona, Casanova 143, 08036 Barcelona, Spain. Phone: +34-93- 4021906; Fax: +34-93-4035260. E-mail: jpotau@med.ub.es 75

J. M. Potau,M. Canals,J. Costa,M. D. Merindano and D. Ruano MATERIALS AND METHODS Thirty glaucomatous trabecular meshworks and 10 trabecular meshworks with no known disease w e re used. Non-glaucomatous trabecular meshworks were obtained from sclero c o rneal rings remaining after extraction of central corneal buttons for transplantation that were pro c u red by the Hospital Clinic Eye Bank in Barcelona. Donor age ranged from 30 to 60 years. Glaucomatous trabecular meshworks were obtained from surgical trabeculectomy pieces taken by the same surgeon from patients with a previous diagnosis of primary open-angle glaucoma. All patients selected had an intraocular pressure greater than 21 mmhg and characteristic visual field changes after 1 year under medical treatment. Patient age ranged from 40 to 65. All surgical interventions were performed at the Ophthalmology Service of Hospital Clínic i Provincial in Barcelona. All specimens were fixed in Karnovsky s solution for a period of time not longer than 24 hours immediately after collection. The specimens were then processed for scanning electronic microscopy using standard preocedures. Observations were made using a Hitachi S2300 scanning electron microscope at the Electron Microscopy Service of our University. The atomic composition of determined areas of the intracameral surface of some of the specimens included in the study was analyzed using back-dispersed electrons and X-ray energy dispersion microanalysis with a Cambridge Stereoscan 120 microscope. RESULTS Scanning electron microscopic observation of non-glaucomatous trabecular meshworks allowed us to observe the cylindricaly-shaped uveal beams running from the iris root to the c o rneal periphery, and the corneoscleral beams running from the scleral spur to Schwalbe s ring. Both types of beams delimited a larg e number of trabecular orifices with a highly permeable aspect (Fig. 1). Study of glaucoamatous trabecular meshworks revealed that in many cases (50%) there was partial or total obstruction of the trabecular orifices. In these specimens, a layer of dense, homogeneous and continuous material covered the intracameral s u rface, causing the above-mentioned obstruction (Fig. 2). In some cases, this material only covere d the anterior portion of the trabecular meshwork while the posterior portion remained perm e a b l e (Fig. 3). Fig. 1.- Scanning electron microscopy (SEM) (x 200). Intracameral surface of a non-glaucomatous trabecular meshwork. Note the permeability of the trabecular orifices. 76

Obstruction of trabecular orifices in primary open-angle glaucoma Fig. 2.- SEM (x 200). Detail of the intracameral surface of a glaucomatous trabecular meshwork with trabecular orifices completely obstructed by a layer of dense and homogenous material. Fig. 3.- SEM (x 150). Glaucomatous trabecular meshwork with obstruction of the anterior-most trabecular orifices and permeable posterior orifices. 77

J. M. Potau,M. Canals,J. Costa,M. D. Merindano and D. Ruano Fig. 4.- SEM (x 3000). Detail of a flat cell located on the dense and homogeneous material obstructing a trabecular orifice of a glaucomatous trabecular meshwork. Fig. 5.- SEM (x 1500). A flat cell with an irregular contour can be identified above the homogeneous material obstructing the trabecular orifices. 78

Obstruction of trabecular orifices in primary open-angle glaucoma In some of the specimens cell-like structures were observed superficially to the material covering the intracameral surface of the glaucomatous trabecular meshwork (Fig. 4). These celllike structures had a flat morphology, with irregular contours and diameters ranging from 15 to 20 µm (Fig. 5). They also emitted cytoplasmatic expansions in varying numbers and morphology that contacted one another or contacted the endothelial cells of neighbouring trabecular beams. Three trabecular meshworks that were completely obstructed with the previously described deposit material were observed with scanning electron microscopy using back-dispersed electrons. The purpose in studying these cases was to see whether this material had originated as a contaminant from the silver adhesive used in scanning electron microscopy to fix the specimens to the stubs. The images obtained revealed the absence of silver at the intracameral surface of the obstructed areas (Fig. 6). In addition, X- ray energy dispersion microanalysis performed on the obstructed areas of these specimens revealed the existence of two peaks originating from the gold coating of the specimens. No peak corresponding to the silver used in the adhesive was observed (Fig. 7). DISCUSSION Our findings point to the existence of significant morphological and structural changes in the trabecular meshwork in primary open-angle glaucoma that may be directly related to this pathology. Obstruction of the trabecular orifices is a mechanical handicap for the correct drainage of the aqueous humour from the anterior chamber to Schlemm s canal. This may cause aqueous retention in the anterior chamber, with a subsequent increase in intraocular pressure. The observation of a dense and homogeneous deposit material obstructing the orifices of some glaucomatous trabecular meshworks has previously been reported by Chaudry et al. (1979), Dueker (1980) and Vinuesa et al. (1982). These authors reported similar changes to those observed in the present study, but failed to offer any possible explanation for the composition and origin of this material. On the other hand, the studies of Quigley and Addicks (1980), Maglio et al. (1980) and Gieser et al. (1981) rule out the obstruction of trabecular orifices as a possible mechanism in the development of primary open-angle glaucoma since the permeability of these orifices was complete in all the trabecular meshworks observed by Fig. 6.- SEM with back-dispersed electrons (x 129). The image shows that the material obstructing the trabecular orifices does not consist of silver from the adhesive, which is concentrated at the base of the sample. 79

J. M. Potau,M. Canals,J. Costa,M. D. Merindano and D. Ruano Fig. 7.- X-ray energy dispersion microanalysis of the homogeneous material obstructing the trabecular orifices. No silver is detected in its atomic composition. Both gold peaks are generated by the coating of the sample. them. Maglio et al. (1980) suggested that the deposits obstructing the trabecular orifices observed by Chaudry et al. (1979) may have been due to contamination of the specimen s surface with the silver adhesive used to fix the sample to the stub. We discarded this possibility by observing obstructed trabecular meshworks under scanning electron microscopy with backdispersed electrons and by performing X-ray energy dispersion microanalysis on the obstructed areas. Both techniques ruled out the presence of silver in the material analyzed. The observation of cell-like structures in the layer of deposit material may explain how this latter originates. In our opinion, these cells may be endothelial cells from trabecular beams undergoing a process of migration. For different reasons, such as increased phagocytosis of pigment granules and other deposit materials, trabecular endothelial cells may become activated and start a migration process that leads them to leave the trabecular beam on which they lie. As these cells move, they use the underlying layers of beams as a substrate on which they deposit an extracellular matrix that forms the homogeneous and dense material that finally obstructs the trabecular orifices. The migration stops when an endothelial cell contacts another endothelial cell of a neighbouring beam through its cytoplasmic expansions and the two cells finally fuse together. Through this mechanism, the layer of material extends and progressively obstructs the more superficial trabecular orifices. The theory relating endothelial cell activation to the obstruction of trabecular orifices is supported by the work of diff e rent authors such as Sherwood and Richardson (1988) or Johnson et al. (1989), who demonstrated that trabecular endothelial cells can become activated and migrate after the phagocytosis of diff e rent types of particles, among them pigment granules. On the other hand, authors such as Buller et al. (1990) and Zagórski et al. (1990) have reported that postphagocytic migration of human trabecular endothelial cells is either very limited or does not occur. The observation in some specimens of more p ronounced changes in the anterior portion of the trabecular meshwork can be explained in terms of the participation of Descemet s membrane and c o rneal endothelial cells in a process similar to that previously described, which covers the trabecular meshwork backwards from the front. This observation is based on the fact that both endothelial cell types, trabecular and corn e a l, have a common embryonic origin and can theref o re become activated in response to similar stimuli and behave similarly, as reported by Tr i p a t h i and Tripathi (1989) and Foets et al. (1992). ACKNOWLEDGEMENTS This project was funded by the Fondo de Investigaciones Sanitarias de la Seguridad Social (The Social Security Health Research Fund) (FISS 97/0177). 80

Obstruction of trabecular orifices in primary open-angle glaucoma REFERENCES BULLER C, JOHNSON DH and TSCHUMPER RC (1980). Human trabecular meshwork phagocytosis. Observations in an organ culture system. Invest Ophthalmol Vis Sci, 31: 2156-2163. CHAUDRY HA, DUEKER DK, SIMMONS RJ, BELLOWS AR and GRANT WM (1979). Scanning electron microscopy of trabeculectomy specimens in open-angle glaucoma. Am J Ophthalmol, 88: 78-92. DUEKER DK (1980). Surgical specimens in open-angle glaucoma. Ann Ophthalmol, 12: 1070-1075. FOETS B, VAN DER OORD J, ENGELMANN K and MISSOTTEN L (1992). A comparative immunohistochemical study of human corneoscleral tissue. Graefe s Arch Clin Exp Ophthalmol, 230: 269-274. GIESER DK, TANENBAUM M, SMITH ME, KASS MA, CHRISTY EN, FRIESEN H, OTTERLEI O and BECKER B (1981). Amorphous coating in open-angle glaucoma. Am J Ophthalmol, 92: 130-132. JOHNSON DH, RICHARDSON TM and EPSTEIN DL (1989). Trabecular meshwork recovery after phagocytic challenge. Curr Eye Res, 8: 1121-1130. MAGLIO M, MCMAHON C, HOSKINS D and ALVARADO J (1980). Potential artifacts in scanning electron microscopy of the trabecular meshwork in glaucoma. Am J Ophthal - mol, 90: 645-653. QUIGLEY HA and ADDICKS EM (1980). Scanning electron microscopy of trabeculectomy specimens from eyes with open-angle glaucoma. Am J Ophthalmol, 90: 854-857. SHERWOOD ME and RICHARDSON TM (1988). Phagocytosis by trabecular meshwork cells: sequence of events in cats and monkeys. Exp Eye Res, 46: 881-895. TRIPATHI BJ and TRIPATHI RC (1989). Neural crest origin of human trabecular meshwork and its implications for the pathogenesis of glaucoma. Am J Ophthalmol, 107: 583-590. VINUESA JM, RODRÍGUEZ ML, VÁZQUEZ R, BARAHONA JM and MARCOS M (1982). Estudio de la malla trabecular con microscopía electrónica de barrido en el ojo normal y en el glaucoma crónico simple. Arch Soc Esp Oftal, 42: 105-115. ZA G Ó R S K I Z, HO L B A C H L, RU M M E LT C, GO S S L E R B and NA U M A N N GO (1990). Proliferation of corneal epithelial and endothelial cells in the trabecular region of human donor c o rneas in organ culture. Ophthalmic Res, 22: 51-56. 81