Automating Wet Chemical Analysis

Similar documents
Automating Wet Chemical Analysis. William Lipps Market Specialist for Water Analyzer Products December 11, 2008

Automation of Wet Chemical Analysis Methods

Cyanide Analysis with the CNSolution 3100

University Wet Chemistry Analyzer Packages

Speed and flexibility

DI 3500 Discrete Aoalvzer

Automated Photometry. Presented by Scott Tucker. Instruments

A New On-line Cyanide Analyzer for Measurement of Cyanide in Hydrometallurgical Processing of Precious Metal Ores

Continuous Flow Analysis Methods David Davey University of South Australia. 21 February

SKALAR. your partner in chemistry automation. The San ++ continuous flow analyzer

By Mohsin Al-Saleh Clinical Biochemistry Department (SQUH)

Cyanide Methods for Lachat Automated Ion Analyzers. Flow Injection Analysis

Flow Solution FS 3700 Automated Chemistry Analyzer

Flow Solution FS 3700 Automated Chemistry Analyzer

EPA Office of Water Method Update Rule Final August 28, 2017 William Lipps October 2017

Method for Nitrite determination on Low-Range Samples

SMARTCHEM 300 STATE-OF-THE-ART DIRECT READ DISCRETE ANALYZER FOR AUTOMATED CHEMISTRIES

ASTORIA PACIFIC. Automated Wet-Chemistry Analyzers and Diagnostic Reagents. rapid-t

SKALAR. your partner in chemistry automation. The San ++ continuous flow analyzer

SMARTCHEM 200 STATE-OF-THE-ART DIRECT READ DISCRETE ANALYZER FOR AUTOMATED CHEMISTRIES

Fertilizer Methods List for Automated Ion Analyzers. Flow Injection Analysis

Application Note No. 310/2018

SMARTCHEM 140 DIRECT READ DISCRETE ANALYZER FOR SIMPLE AND AUTOMATED CHEMISTRIES

Nitrate plus Nitrite and Nitrite in Seawater by Segmented Flow Analysis (SFA)

APPRENTICESHIP AT SKALAR S LABORATORY. The organization Skalar Analytical BV. The product lines of Skalar Analytical BV

Ground Water & UST Samples: Containers, Preservation and Hold Times Table

SMARTCHEM 140. DIRECt READ DISCREtE ANAlyZER FOR SIMPlE AND AUtOMAtED CHEMIStRIES

SECTION D.2 AMMONIA NITROGEN

Cyanide Analysis of Wastewater Samples from FCC and Hydrocracking Operations

METHOD 9012 TOTAL AND AMENABLE CYANIDE (COLORIMETRIC, AUTOMATED UV)

Astoria-Pacific proudly offers our rapid-t software for the ChemWell-T an easy-to-use, compact automated chemistry analyzer:

3. Chemical industry. Because of their modular design, the instruments in the TOC-L series can be equipped for any possible measurement

O Sodium Bicarbonate, NaHCO 3 Ammonium Molybdate Tetrahydrate, (NH 4. O 4 Sodium Chloride, NaCl Ascorbic Acid, C 6 H 8 O 6

2035 Process Analyzer. Customized online monitoring of industrial processes and wastewater

Total Kjeldahl Nitrogen by Gas Diffusion and Flow Injection Analysis (FIA)

DETERMINATION OF NITRATE AND NITRITE BY ZONE FLUIDICS

Nitrogen, ammonia, colorimetry, salicylate-hypochlorite, automated-segmented flow

Kjeltec 2300 Analyzer Unit

Total Phosphorus, USEPA by Flow Injection Analysis (FIA)

Glossary of Common Laboratory Terms

Ideal and powerful solution

Analysis of domestic sludge using the Agilent 4200 MP-AES

EnAlgae SOP sheet: Silicate - SFA. 1. Purpose This procedure is to analyse seawater and freshwater for silicate, SiO2.

Flow Injection Analysis for the Determination of Ammonia in Exhaust Gas of Thermal Power Plant

Thermo Scientific Orion Fluoride Ion Selective Electrodes The standard in fluoride ion analysis EPA compliant

METHOD 9012B TOTAL AND AMENABLE CYANIDE (AUTOMATED COLORIMETRIC, WITH OFF-LINE DISTILLATION)

columns IonPac AS22 Anion-Exchange Column

IC5000 Ion Chromatography System

High-Pressure Electrolytic Carbonate Eluent Generation Devices and Their Applications in Ion Chromatography Systems

Analytical Method Name Preservative Container Water and Wastewater. Inorganics SM203 Corrosivity <4C 1L Plastic 1

Total Kjeldahl Nitrogen (TKN), USEPA by Flow Injection Analysis (FIA)

SpeedDigester K-436, K-439 / KjelFlex K-360 Nitrogen Determination in Nitrate-Free Fertilizer according to the micro-kjeldahl Method 074/2011

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

UDK. Distillation Units Series. A Full Range of Solutions for Kjeldahl Distillation LABSOLUTIONS

Update on ASTM and Standard Methods method development activities

Nitrate Reductase (NR) Colorimetric Assay Kit

Chloride by Flow Injection Analysis (FIA)

Low Level Phosphorus: A Method Comparison Study

Introduction. Terminology

Method Abstract. Flow Solution Fluoride, USGS by ISE and FIA

Automation of Routine Microplate Pipetting and Dispensing

New On-Line High-Pressure Electrolytic Eluent Generators for Ion Chromatography

Removal of suspended and dissolved organic solids

1) Alkaline Persulfate Digestion for TN, TDN and TDPTotal Dissolved Nitrogen. a) Scope and Application

Determinations by Atomic Absorption Spectroscopy and Inductively Coupled Plasma-Atomic Emission

Standard Operating Procedure for: Conductivity Using Cole-Parmer Traceable Portable Conductivity Meter. Missouri State University.

Anion and Cation analysis with Professional IC - automatic dilution and sample preparation with SPM

METHOD 9210 POTENTIOMETRIC DETERMINATION OF NITRATE IN AQUEOUS SAMPLES WITH ION-SELECTIVE ELECTRODE

DATES: LAB: Liquid Chromatography Separation of Grape Kool-Aid

cobas c 111 analyzer Big analyzer performance in a small package

6-24 hours e. Coliform, Fecal and Total W, DW P,G Cool, 4 C, 0.008% Na 2 S 2 O 3. Fecal Streptococci W P,G Cool, 4 C, 0.

Single Method On-line Analyzers. ADI 2016 Titrolyzer ADI 2018 Ion-Analyzer ADI 2019 Process Colorimeter

TaKaRa BCA Protein Assay Kit

Cyanide, Total or Weak Acid Dissociable, by Manual Distillation - PBM

Time Savings and Improved Reproducibility of Nitrate and Nitrite Ion Chromatography Determination in Milk Samples

EXP. 9 EVALUATION OF METHODS FOR DETECTING AMMONIUM: ION SELECTIVE ELECTRODES AND SPECTROSCOPY

TOUR OF SOIL CHEMISTRY LABS (09/22/07)

Method to 0.50 mg/l NH 3 N Powder Pillows

columns IonPac AS18 Anion-Exchange Columns

110 Lowell Rd Hudson, NH USA Tel:

Fusion UV/Persulfate TOC Analyzer

Scope and application: For wastewater, seawater, drinking water, surface water and process water.

Hach Company TNTplus TM Phosphorus Spectrophotometric Measurement of Phosphorus in Water and Wastewater

APPENDIX II REQUIRED CONTAINERS, PRESERVATION TECHNIQUES, AND HOLDING TIMES FOR SOLID WASTE AND WASTEWATER

ION CHROMATOGRAPHY SYSTEM S 150

Method to 0.50 mg/l NH 3 N Powder Pillows

Manganese III Digestion Method * (with chloride removal)

Not Just for Paint Chips Anymore. High Throughput, Open Vessel Microwave Digestion of Matrices Requiring Moderate Conditions

Standard Operating Procedure for the Analysis of Nitrate/Nitrite and Nitrite in Fresh Waters CCAL 31B.1

Theory of Ion Chromatography

IDENTIFYING UNKNOWN CHEMICALS IN SCIENCE LABS

Single Method On-line Analyzers

HPLC Winter Webinars Part 2: Sample Preparation for HPLC

Analysis of Cyanide (Total, Weak Acid Dissociable, and Free) - PBM

PRELIMINARY ACTIVITY FOR

Supernatant: The liquid layer lying above the solid layer after a precipitation reaction occurs.

F- Cl- Br- I- CN- S2- NO3-

columns IonPac AS17-C Anion Exchange Column

High-Speed Environmental Analysis Using the Agilent 7500cx with Integrated Sample Introduction System Discrete Sampling (ISIS DS)

CP3000. Automated Coagulation System POWE R F U L LY CO M PAC T STREAM LI NED EF F I CI ENCY SI M PLE AND INTUITIVE CH OO SE T RA NS FO R MATIO N

Transcription:

Automating Wet Chemical Analysis

Who Should Automate? Anyone looking to improve laboratory efficiency Environmental Agricultural Food and beverage Pharmaceutical Mining Etc.

Advantages of Automating Save time Decrease cost Improve quality Reduce waste Proven methods

Benefits of Automation Improve efficiency Release staff from mundane chores More samples per day Increase capacity

Economic Advantage Increased capacity = higher profit Silent hours 3x throughput

Simplest Form of Automation Making a mundane task easy

Automated Chemistries Alkalinity Ammonia Chloride Nitrate Nitrite Nitrogen, Total Kjeldahl (TKN) Phenolics ortho-phosphate Total Phosphorus Silica Sulfide Sulfate

Sample Types Brackish waters Drinking water Groundwater Wastewaters Surface water Industrial waste Process water Plating baths Seawater Soil and plant extracts Tobacco extracts

Sample Preparation Digestion Distillation Solvent extraction Gas diffusion Dialysis

Sample Preparation Examples Total Cyanide Total Phenolics Total Nitrogen Total Phosphorus Surfactants

Manual Method Process Detector Boring and Mundane

Criteria for Automation Cost divided by 3-5 years should be less than annual cost of the manual method (labor + reagents) easy-to-use, and not complicated Better results than manual method

Answer These Questions How many samples do I have? How many different tests will I do? How many different tests per sample? How many samples per same test?

More Questions Will I have a lot of samples for the same tests? Or, will I have a lot of tests for a few samples?

Answers to Questions It is economical to automate both a lot of tests for few samples a lot of samples for a few tests The automation technique is what varies

Technology Automated Wet Chemistry Continuous Flow Robotic SFA FIA Discrete

Continuous Flow Continuous flowing stream Mixing coils Detector

Segmented Flow Analysis (SFA) Original Automated Analyzer Approved in regulatory test methods

SFA Sample Segment After segmentation within chemistry cartridge. Sample gas Sample gas Sample

SFA Sample Segment Gas bubble must occlude the tubing Sample Segment Gas

SFA Peak Shape Steady-State Gas

SFA Peaks: Ammonium

Advantages of SFA Low MDL Excellent Precision Steady state reactions Limited dispersion High throughput Easily expandable

Flow Injection Analysis (FIA) The No Bubble Alternative

FIA Sample Segment Carrier Carrier Sample segment

FIA Peak Shape Not normally at steady-state

FIA Peaks: Cyanide

Advantages of FIA High throughput Excellent Precision Ease of use No de-bubbling Rapid startup and shutdown

SFA vs. FIA

Comparing SFA & FIA* SFA Sample intro aspiration FIA injection Volume 200 ul 200 ul Max delay time 10 minutes 2 minutes Sample/hour 40-90 30-120 RSD < 2% < 2% Reagent (ml) 2-3 2-4 * OI Analytical FS3100

When to Use CFA Choose CFA when automating a lot of samples for a few tests! Exception CNSolution - no distillation makes CN analysis economical regardless of sample load

Discrete Chemical Analysis an alternative approach to automated chemical analysis

What is a Discrete Analyzer? Reactions in individual cuvettes Mixing within the cuvette Measurement within the cuvette

Multi-chemistry Analyzer True Random Access Automatic Method Interchange Hands off operation

Chemical Analysis Made Simple

Discrete Analyzer - Operation Sample dispensed into cuvette Reagents added to sample Sample incubates in cuvette Instrument measures absorbance Result calculated

Discrete Analyzer - Operation No peaks single absorbance reading No interaction between samples Equilibrium reactions (maximum color)

Discrete Analyzer Benefits Reduces Turn Around Time Unattended Operation Only runs requested tests Standards Prepared Automatically Automatically Dilutes over-range samples No pump tubes

When to Use Discrete Choose discrete when automating a few samples for a lot of tests. Choose a discrete analyzer when running a variety of matrices, or parameters.

ACA Applications Water utilities, Environmental contract labs, Government agencies, Manufacturing, Academia, Mining

EPA Methods Drinking Water Wastewater Storm water Biosolids Groundwater Hazardous Waste

Soil & Plant Extracts Potassium Chloride Bray Olson Mehlich Morgan Acetic Acid

Industrial Analysis Seawater Process water Electroplating Precipitation Impinger Solutions

Comparing CFA & Discrete Discrete CFA Reagents per test Continuously flowing Carryover None Need wash solution Throughput Function of # reagents Determined by peak width

Comparing CFA & Discrete Sensitivity # Tests per run Fluid System Discrete Standard Detector Limited by programming Disposable cuvettes CFA ER Detector Limited by # detectors Pump tubes

Comparing CFA & Discrete Operator maintenance Discrete Limited CFA Change pump tubes Initial setup per test Final teardown per test none 5 10 minutes none 5 10 minutes

Choosing an ACA Technique The technique to use depends on: Sample load Tests per sample Analytical Requirements (MDL, etc) Make educated choice on what is best for your application

Examples Automated Analyzers FS 3100 FS IV CN Solution 3100 DA 3500

For Additional Information Please visit our website at: www.oico.com Questions and Comments?