Standard Test Methods for Precoat Capacity of Powdered Ion-Exchange Resins 1

Similar documents
Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate 1

Standard Test Method for Thermal Conductivity of Refractories 1

Standard Test Methods for Glass-Bonded Mica Used as Electrical Insulation 1

Standard Test Method for Rapid Determination of Carbonate Content of Soils 1

Standard Guide for Determination of the Thermal Resistance of Low-Density Blanket-Type Mineral Fiber Insulation 1

Standard Test Method for Coefficient of Linear Thermal Expansion of Plastics Between 30 C and 30 C with a Vitreous Silica Dilatometer 1

Standard Practice for Calculating Formulation Physical Constants of Paints and Coatings 1

Standard Practice for Heat Aging of Plastics Without Load 1

Standard Test Method for Determination of Trace Thiophene in Refined Benzene by Gas Chromatography 1

Standard Test Method for Temperature-Resistance Constants of Alloy Wires for Precision Resistors 1

Standard Test Method for Measuring Apparent Viscosity at High-Temperature and High-Shear Rate by Multicell Capillary Viscometer 1

Standard Test Method for Salts in Crude Oil (Electrometric Method) 1

Standard Test Methods for Water in Crude Oils by Coulometric Karl Fischer Titration 1

Standard Test Method for Field Measurement of Sound Power Level by the Two- Surface Method 1

Standard Test Method for Salts in Crude Oil (Electrometric Method) 1

Standard Test Methods for Fluoride Ion in Water 1

Standard Test Method for D-C Resistance or Conductance of Moderately Conductive Materials 1

Standard Test Method for Determination of the Thermal Conductivity of Anode Carbons by the Guarded Heat Flow Meter Technique 1

Standard Test Methods for Physical and Chemical Properties of Particulate Ion- Exchange Resins 1

Designation: D (Reapproved 2009)

Standard Test Method for Thermal Flow, Cure, and Behavior Properties of Pourable Thermosetting Materials by Torque Rheometer 1

Standard Test Method for Determination of Free Formaldehyde in Emulsion Polymers by Liquid Chromatography 1

Standard Test Methods for Measurement of Thermal Expansion of Rock Using a Dilatometer 1

SOUTH AFRICAN NATIONAL STANDARD. Standard test methods for lead in water

Standard Test Methods for Density and Specific Gravity (Relative Density) of Plastics by Displacement 1

Standard Test Methods for Density and Specific Gravity (Relative Density) of Plastics by Displacement 1

Standard Test Method for Mean Specific Heat of Thermal Insulation 1

Standard Test Method for Determination of the Point Load Strength Index of Rock 1

Standard Test Method for Total Energy Impact of Plastic Films By Dart Drop 1

SOUTH AFRICAN NATIONAL STANDARD

Standard Test Method for Thermal Endurance of Film-Insulated Round Magnet Wire 1

Standard Test Method for Open Hole Tensile Strength of Polymer Matrix Composite Laminates 1

DRAFT UGANDA STANDARD. Standard Test Methods for Specific Gravity, Apparent, of Liquid Industrial Chemicals

Standard Test Method for Base Number of Petroleum Products by Potentiometric Perchloric Acid Titration 1

3.2.2 principal material coordinate system, n a coordinate system with axes that are normal to the planes of symmetry inherent to a material

Standard Test Method for Chemical Resistance of Fiberglass (Glass Fiber Reinforced Thermosetting-Resin) Pipe in a Deflected Condition 1

ASTM Designation: D Standard Test Method for Determination of Iodine Number of Activated Carbon

Standard Test Method for In Situ Determination of Direct Shear Strength of Rock Discontinuities 1

Standard Test Method for Anions in Water by Chemically Suppressed Ion Chromatography 1

METHOD 9040B. ph ELECTROMETRIC MEASUREMENT

Standard Test Method for Chlorine in Aromatics by Monochromatic Wavelength Dispersive X-ray Fluorescence Spectrometry 1

Standard Test Method for Aluminum in Water 1

Standard Test Methods for Acidity or Alkalinity of Water 1

标准分享网 免费下载 The standard is downloaded from Designation: D An American National Standard Standard Test Method for Linea

Standard Test Method for Unconfined Compressive Strength of Cohesive Soil 1

SOUTH AFRICAN NATIONAL STANDARD

Standard Test Method for Determination of the Point Load Strength Index of Rock and Application to Rock Strength Classifications 1

Chloramine (Mono) and Nitrogen, Free Ammonia

Tetraphenylborate Method Method to 7.0 mg/l K Powder Pillows

INTERNATIONAL STANDARD

Standard Test Methods for Sodium Carboxymethylcellulose 1

Standard Practice for Calculating Yellowness and Whiteness Indices from Instrumentally Measured Color Coordinates 1

Standard Test Methods for Conductivity Type of Extrinsic Semiconducting Materials 1

Standard Test Method for Evaluating the Resistance to Thermal Transmission of Materials by the Guarded Heat Flow Meter Technique 1

Scope and application: For water, wastewater and seawater. Distillation is required for wastewater and seawater.

Standard Test Method for Sulfur in Gasoline and Diesel Fuel by Monochromatic Wavelength Dispersive X-ray Fluorescence Spectrometry 1

Standard Test Method for Unconfined Compressive Strength of Cohesive Soil 1

Cadmium Reduction Method Method to 10.0 mg/l NO 3 N (MR, spectrophotometers) 0.2 to 5.0 mg/l NO 3 N (MR, colorimeters)

The Use of Expanded Shale, Clay and Slate Lightweight Aggregates in Granular Geotechnical Fills

Standard Test Methods for Plane-Strain Fracture Toughness and Strain Energy Release Rate of Plastic Materials 1

Cadmium Reduction Method Method to 0.50 mg/l NO 3 N (LR) Powder Pillows

This document is a preview generated by EVS

Chromium, Total. Alkaline Hypobromite Oxidation Method 1 Method to 0.70 mg/l Cr (spectrophotometers) 0.01 to 0.60 mg/l Cr (colorimeters)

SOIL ORGANIC CONTENT USING UV-VIS METHOD

METHOD 13B - DETERMINATION OF TOTAL FLUORIDE EMISSIONS FROM STATIONARY SOURCES (SPECIFIC ION ELECTRODE METHOD)

STATE OF COLORADO DESIGN CRITERIA FOR POTABLE WATER SYSTEMS WATER QUALITY CONTROL DIVISION. Price: $5.00. Revised March 31, 1997

Cadmium Reduction Method Method to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls

Alpha-, beta- and gamma-cellulose in pulp. 1. Scope

ISO 1871 INTERNATIONAL STANDARD. Food and feed products General guidelines for the determination of nitrogen by the Kjeldahl method

Standard Test Method for Determination of the In-Situ Stress in Rock Using the Hydraulic Fracturing Method 1

Tex-620-J, Determining Chloride and Sulfate Contents in Soil

Rubber compounding ingredients Sulfenamide accelerators Test methods

SAFETY NOTE: Before beginning this procedure, read all of the Material Safety Data Sheets for the chemicals listed in Section 5 of this procedure.

Mercuric Thiocyanate Method Method to 25.0 mg/l Cl Reagent Solution

PRETREATMENT TECHNICAL DATA SHEET A CHROME-FREE FINAL RINSE PRODUCT DESCRIPTION

NICKEL-63/59 IN WATER

Nitrogen, Total Inorganic

Standard Test Methods for Plane-Strain Fracture Toughness and Strain Energy Release Rate of Plastic Materials 1

STANDARD OPERATING PROCEDURE No. 52 STATIC ACID GENERATION (NAG) TEST

ProPac WCX-10 Columns

NANOSTONE Cleaning Guidelines for Spiral E-Coat Elements

NOTES INTRODUCTION EXPERIMENTAL

Standard Test Method for Young s Modulus, Tangent Modulus, and Chord Modulus 1

Instrument Sample cell orientation Sample cell DR 6000 DR 3800 DR 2800 DR 2700 DR 5000 DR The fill line is to the right.

Potentiometric measurement of ph

Standard Practice for Calculating Thermal Transmission Properties Under Steady- State Conditions 1

METHOD 3010A ACID DIGESTION OF AQUEOUS SAMPLES AND EXTRACTS FOR TOTAL METALS FOR ANALYSIS BY FLAA OR ICP SPECTROSCOPY

Standard Guide for Sampling and Testing Volatile Solvents and Chemical Intermediates for Use in Paint and Related Coatings and Material 1

Total Carboxylic Acid Group Content Applicable Products: Carbopol * Polymers and Pemulen * Polymeric Emulsifiers

Sodium Chloride - Analytical Standard

METHOD 9210 POTENTIOMETRIC DETERMINATION OF NITRATE IN AQUEOUS SAMPLES WITH ION-SELECTIVE ELECTRODE

Working in the Chemistry Laboratory

Persulfate Digestion Method Method to 150 mg/l N (HR) Test N Tube Vials

Persulfate Digestion Method Method to 25.0 mg/l N (LR) Test N Tube Vials

Colorimetric Method Method to 0.70 mg/l Ag Powder Pillows

Method NumberUSTUR 150

The analysis of organic acid content of additives, premix, feed, and water.

Phosphorus, Total. USEPA 1 PhosVer 3 with Acid Persulfate Digestion Method Method to 3.50 mg/l PO. Test preparation

Standard Test Method for Thermal Endurance of Rigid Electrical Insulating Materials 1

METHOD 9252A CHLORIDE (TITRIMETRIC, MERCURIC NITRATE)

Transcription:

Designation: D 4266 96 (Reapproved 2001) An American National Standard Standard Test Methods for Precoat Capacity of Powdered Ion-Exchange Resins 1 This standard is issued under the fixed designation D 4266; the number immediately following the designation indicates the year of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A superscript epsilon (e) indicates an editorial change since the last revision or reapproval. 1. Scope 1.1 These test methods cover the determination of the operating ion-exchange capacity of both powdered cationexchange resins (hydrogen form) and powdered anionexchange resins (hydroxide form). These test methods are intended for use in testing new powdered ion-exchange resins when used for the treatment of water. The following two test methods are included: Test Method A Operating Capacity, Anion-Exchange Resin, Hydroxide Form Test Method B Operating Capacity, Cation-Exchange Resin, Hydrogen Form Sections 7-15 16-24 1.2 The values stated in SI units are to be regarded as the standard. The inch-pound units given in parentheses are for information only. 1. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. 2. Referenced Documents 2.1 ASTM Standards: D 1125 Test Methods for Electrical Conductivity and Resistivity of Water 2 D 1129 Terminology Relating to Water 2 D 119 Specification for Reagent Water 2 D 2687 Practices for Sampling Particulate Ion-Exchange Materials D 4456 Test Methods for Physical and Chemical Properties of Powdered Ion-Exchange Resins E 200 Practice for Preparation, Standardization, and Storage of Standard and Reagent Solutions for Chemical Analysis 4. Terminology.1 Definitions of Terms Specific to This Standard:.1.1 powdered ion-exchange material,, n an ionexchange resin that has undergone post-manufacturing size reduction to less than 00 µm..1.2 resin dosage, n the weight of mixed resin applied per unit area of precoatable filter surface. This is expressed as dry pounds per square foot..1. resin floc, n that voluminous aggregate formed when powdered anion-exchange resin and powdered cationexchange resin are slurried together in an aqueous suspension..1.4 resin ratio, n the ratio of the weights of powdered cation-exchange resin to powdered anion-exchange resin used to prepare a resin slurry. If not otherwise indicated, it is understood to be the ratio of the dry resin weights..2 Definitions For definitions of other terms used in these test methods, refer to Terminology D 1129. 4. Significance and Use 4.1 The salt removal capacity of a powdered resin precoat is limited by the capacity of either the anion-exchange resin or the cation-exchange resin contained in it. Applications include condensate polishing in fossil-fueled electric generating plants, as well as condensate polishing, spent fuel pool water treatment, reactor water treatment, and low-level radioactive liquid waste treatment in nuclear-powered electric generating plants. 4.2 By determining the ion-exchange capacity profile of either a cation exchange resin or an anion-exchange resin (capacity expended per unit of time under specific conditions), it is possible to estimate runlength and remaining capacity when treating a liquid of the same makeup. Although they cannot accurately predict performance during condenser leaks, these test methods are useful for determining operating capacities as measured under the test conditions used. 4. These test methods may be used to monitor the performance of either powdered anion-exchange resin or powdered cation-exchange resin. The total capacity of either resin depends primarily upon the number density of ion-exchange sites 1 These test methods are under the jurisdiction of ASTM Committee D19 on Water and are the direct responsibility of Subcommittee D19.08 on Membranes and Ion-Exchange Materials. Current edition approved July 10, 1996. Published November 1996. Originally published as D 4266 8. Last previous edition D 4266 8 (1990)e 1. 2 Annual Book of ASTM Standards, Vol 11.01. Annual Book of ASTM Standards, Vol 11.02. 4 Annual Book of ASTM Standards, Vol 15.05. Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States. 1

within the resin. The operating capacity is a function of the total capacity, degree of conversion to the desired ionic form when received, and properties of the resin and the system that affect ion exchange kinetics. 5. Purity of Reagents 5.1 Reagent grade chemicals shall be used in all tests. Unless otherwise indicated, it is intended that all reagents shall conform to the specifications of the Committee on Analytical Reagents of the American Chemical Society, where such specifications are available. 5 5.2 Purity of Water Unless otherwise indicated, references to water shall be understood to mean Type II reagent water, Specification D 119. 6. Sampling 6.1 Obtain a representative sample of the powdered ionexchange resin in accordance with Practices D 2687 but substituting a 12.5-mm ( 1 2-in.) inside diameter tube. TEST METHOD A OPERATING CAPACITY, ANIONEXCHANGE RESIN, HYDROXIDE FORM 7. Scope 7.1 This test method covers the determination of ionexchange capacity, on a dry weight basis, of new powdered anion-exchange resins in the hydroxide form. 7.2 The ion-exchange capacity obtainable in commercial installations depends not only upon the initial state of the powdered resin, but also on how the resin floc is prepared and applied, on the condition of the equipment on which it is to be used, and the ph and general chemistry of the water system being treated. Thus, this test method has comparative rather than predictive value and provides an upper limit on exchange capacity that may be expected. 8. Summary of Test Method 8.1 The powdered anion-exchange resin to be tested is slurried with an appropriate amount of powdered cationexchange resin in the hydrogen form, and the resulting floc is precoated onto a filter disk. Then a dilute standardized solution of a strong acid is fed to the precoat while monitoring the effluent stream conductometrically. 9. Apparatus 9.1 Test apparatus, as shown in Fig. 1, with the following components: 9.1.1 Water Pump adjustable between 0 to 7.57 L/min (0 to 2 gal/min) at 2.76 10 5 Pa (40 psig) pressure. 6 9.1.2 Pressure Gages (2), 0 to 4.17 10 5 Pa (0 to 60 psig) with appropriate snubbers. 9.1. Disk Filter Holder, 142-mm diameter with sufficient clearance above the filter disk to allow for uniform application of resin precoat. 7 9.1.4 Filter-Disk, 142-mm diameter, with nominal retention rating of 25 to 0 µm and absolute retention rating of 40 to 60µm. 8 9.1.5 Flow Metre, 0 to 1.89 L/min (0 to 0 gal/h) with regulating valve. 9.1.6 Beaker, stainless steel, 4 L to volume with bulkhead fittings installed at tubing penetrations. 9.1.7 Chemical Pump, with pumping rate between 8. 10 6 and 8. 10 5 L/s (0 to 00 ml/h) at.45 10 6 Pa (500 psig) pressure. Suction tubing should be.2-mm ( 1 8-in.) outside diameter stainless steel and discharge tubing should be 1.6-mm ( 1 16-in.) outside diameter stainless steel. 9 9.2 Electrical Conductivity Measurement Apparatus, conforming to the requirements given in Test Methods D 1125, Method B. 10. Reagents 10.1 Hydrochloric Acid Solution, Standard (0.10 N) Prepare and standardize as described in Practice E 200. 10.2 Polyacrylic Acid Solution, Standard (1 + 99) Pipet 1 ml of polyacrylic acid 10 (25 weight % solids, MW < 50 000) into a 100 ml volumetric flask and dilute to 100 ml with water. Mix well. Prepare this solution fresh daily. 11. Sample Preparation 11.1 Selection of Proper Sample Weight Use a resin dosage of 1 kg/m 2 (0.2 lb/ft 2 ) and a resin ratio of 2:1. 11.1.1 If the purpose of the capacity test is to eliminate the resin as a consideration in a situation involving a performance problem in a commercial plant, then the capacity test may be performed using the same wet resin ratio and the same resin dosage as is used in the commercial equipment. 11.1.2 Using a resin dosage of 1 kg/m 2 (0.2 lb/ft 2 ), the correct dry weight of resin to be used on a 142-mm diameter filter is 15.5 g. At a resin ratio of 2:1, the dry weights to use are 10. g of cation and 5.2 g of anion exchange resins. The solids contents should be determined by Method B of Test Methods D 4456. 11.1. From the known solids content of the resins, and the dry weight of resin desired for the test, calculate the weight of wet resin to be taken for analysis as follows: W 5 ~B/S! 100 5 Reagent Chemicals, American Chemical Society Specifications, American Chemical Society, Washington, DC. For suggestions on the testing of reagents not listed by the American Chemical Society, see Analar Standards for Laboratory Chemicals, BDH Ltd., Poole, Dorset, U.K., and the United States Pharmacopeia and National Formulary, U.S. Pharmacopeial Convention, Inc. (USPC), Rockville, MD. 6 Millipore pump ZPN100400, or equivalent, has been found satisfactory for this use. 7 Millipore filter holder YY22 1420 with acrylic cylinder XX42 14201 and accessories, or an equivalent, has been found satisfactory for this use. 8 BG or DG filters, available from Pall Corporation, 0 Sea Cove, NY, 11542, or equivalent, have been found satisfactory for this use. 9 Milton Roy pump 1960066002, or an equivalent, has been found satisfactory for this use. 10 Accumer 1510 obtainable from Rohm and Haas Co., Philadelphia, Pa., or an equivalent, is suitable. 2

(A) Pump, adjustable between 0 to 2 gal/min at 40 psig (0.27 MPa) pressure. Millipore pump ZPN1 004 00 or equivalent has been found satisfactory for this use. (B) Gages, 0 to 60 psig (0.41 Pa) pressure with appropriate snubbers. (C) Disk filter holder, 142-mm diameter with sufficient clearance above the filter disk to allow for a 1 / 2 in. (12.5 mm) powdered resin precoat. Millipore filter holder YY22 142 0 with XX42 142 01 acrylic cylinder and accessories has been found satisfactory for this use. (D) Flow metre, 0 to 0 gal/h with regulating valve. (E) Stainless steel beaker, 4-L volume with bulkhead fittings installed at the tubing penetrations. (F) Magnetic stirrer and hotplate. (G) Instrument Pump, with pumping rate between 0 00 ml/h at 100-psig pressure. Provide external pressure relief protection set for 100 psig. Milton Roy pump model 1960066002 has been found satisfactory for this use. (H) Tubing, / 8 in. (9.5 mm), precoat circuit (I) Tubing, 1 / 4 in. (6.4 mm) Including regulating valve (J) Tubing, 1 / 8 in. (.2 mm) (K) Tubing, 1 / 16 in (1.6 mm) Including three-way ball valve and flushing line. (L) Graduated Cylinder, 250 ml. Disk Filters, 142 mm either polypropylene or cellulose Nominal rating 25 0 µm Absolute rating 40 60 µm The Pall Corp has disk filters that have been found satisfactory for this use. (M) Electrical conductivity cell and measurement apparatus, including temperature measurement. FIG. 1 Equipment Layout for Precoat Capacity Determination where: W = weight of wet resin, g, B = weight of dry resin, g, and S = solids content of resin, %. 11.2 Resin Slurry Preparation: 11.2.1 Measure 00 ml of water into each of three 500-mL beakers and place each beaker on a magnetic stirrer. Adjust the stirring speed to as high as possible without appreciable vortex formation. 11.2.2 Accurately weigh three portions each of the cation resin and the anion resin, using the wet weights as determined in 11.1. Place the proper amount of cation resin and anion resin in each of the three beakers and stir gently for 5 min. 11.2. For each beaker, after mixing for 5 min, turn off the magnetic stirrer and allow the floc to settle for 5 min. The desired floc density is obtained if the top surface of the settled floc appears flat and uniform.

11.2.4 If the desired settled floc density is not obtained after the initial 5 min settling time, turn the magnetic stirrer on and add 1 ml of the polyacrylic acid solution. Mix for 5 min, allow the floc to settle an additional 5 min, and check the settled floc density again. Continue with 1 ml incremental additions of the polyacrylic acid solution until the desired floc density is obtained. Use the minimum required amount of polyacrylic acid solution. The function of the polyacrylic acid is to partially declump the floc to ensure optimum precoatability of the slurry. The addition of an insufficient amount of polyacrylic acid will result in a floc that is too voluminous and precoating difficulties and too porous a precoat will result. Conversely, an excess of polyacrylic acid solution will declump the floc excessively, and may result in the release of resin fines, observed as turbidity, that tend to foul the precoat filter. 12. Procedure 12.1 Install a 142-mm diameter disk filter (C) into the filter holder and arrange the apparatus as shown in Fig. 1. 8 12.2 Add water to the beaker (E) as required to maintain a 4-full level. 12. Open the filter inlet sample valve, the flowmeter regulating valve, and the filter holder vent valve. 12.4 Start the water pump (A) and fill and vent the filter disk holder and tubing from the beaker. Close the filter vent valve and the filter inlet valve when full. Further additions of water to the beaker may be required during the filling and venting procedures. 12.5 Add 0.10 N HCl to approximately 5 ml above the 250-mL mark in a graduated cylinder (L). 12.6 Adjust the chemical pump (G) to 1 2-full stroke, open the three-way valve to the vent position and operate the pump to vent the pump and tubing. Shut off the pump when vented and adjust the volume of 0.10 N HCl to exactly 250 ml in the graduated cylinder, if required. Adjust the three-way valve to feed into the filter circulation pump suction. 12.7 Maintain the filter circulation flow rate at 1.406 0.05 L/min (22 6 0.5 gal/h) and maintain the filter inlet pressure at 2.07 Pa (0 psig) by adjusting the water pump output and the flowmeter regulating valve (D). 12.8 Turn on the magnetic stirrer (F) under the stainless steel beaker and adjust the speed so that minimal vortex formation occurs. 12.9 Transfer the contents of one of the resin slurry beakers into the stainless steel beaker and allow the resin to precoat onto the disk filter. Continue circulation until the water above the filter appears clear. 12.10 Open and adjust the inlet valve. Start the chemical pump and adjust the pump rate to maintain a 25 C conductivity of 50 6 2µ S/cm at the inlet sample point. 12.11 Monitor and record the filter inlet and outlet conductivities (M), the stream temperature, and volume of 0.10 N HCl consumed as a function of time. When the filter outlet conductivity rises to 0.2µ S/cm (25 C), or other desired conductivity endpoint, record the volume of 0.10 N HCl consumed, and shut down the chemical pump. 12.12 Turn off the water pump and vent, drain, and clean the filter holder and tubing. 12.1 Repeat 12.1 through 12.12 on each of the remaining two resin slurry samples. 1. Calculation and Interpretation of Results 1.1 For each of the three test runs, calculate the capacity as follows: C 5 ~N V!/B where: C = anion resin capacity, milliequivalents HCl/dry gram anion resin, N = concentration of HCl used, eq/l, V = volume of HCl consumed at endpoint, ml, and B = dry weight of anion resin, g. 14. Report 14.1 Report the average of the capacities for the three tests and the effluent conductivity endpoint used. 15. Precision and Bias 15.1 Precision No statement of precision for this test method can be made since the material is of unknown composition and is prepared, tested, and destroyed in one process. Preparation of this material in sufficient quantity to be subdivided is similarily not possible since the preparation and testing is one procedure. 15.2 Bias Ion exchange resins are the products of a complex, multiple step synthesis involving a polymerization reaction followed by one or more additional reactions to put functional groups on the polymeric structure. Consequently, the true value for any property of the finished product is unknown and a bias statement cannot be given. TEST METHOD B OPERATING CAPACITY, CATION-EXCHANGE RESIN, HYDROGEN FORM 16. Scope 16.1 This test method covers the determination of ionexchange capacity, on a dry weight basis, of new powdered cation-exchange resin in the hydrogen form. 16.2 The ion-exchange capacity obtainable in commercial installations depends not only upon the initial state of the powdered resin, but also on how the resin floc is prepared and applied, on the condition of the equipment on which it is used, and the ph and general chemistry of the water system being treated. Thus, this test method has comparative, rather than predictive, value and gives an upper limit on exchange capacity that may be expected. 17. Summary of Test Method 17.1 The powdered cation exchange resin to be tested is slurried with an appropriate amount of powdered anionexchange resin in the hydroxide form, and the resulting floc is precoated onto a filter disk. Then a dilute standardized solution of a strong base is fed to the precoat while monitoring the effluent stream conductometrically. 18. Apparatus 18.1 Test apparatus, as described in Section 9 and shown in Fig. 1. 4

19. Reagents 19.1 Sodium Hydroxide Solution (0.10 N) Prepare and standardize as described in Practice E 200. 20. Sample Preparation 20.1 Selection of Proper Sample Weight, as described in 11.1. 20.2 Resin Slurry Preparation, as described in 11.2. 21. Procedure 21.1 The procedure is the same as described in Section 12, except wherever HCl appears, it should be substituted by NaOH and a 750 ml graduated cylinder should be subtituted for the 250 ml cylinder in 12.5 and 12.6. 22. Calculation and Interpretation of Results 22.1 For each of the three test runs, calculate the capacity: C 5 ~N V!/B C = cation resin capacity, milliequivalents NaOH/dry gram cation resin, N = concentration of NaOH used, eq/l, V = volume of NaOH consumed at endpoint, ml, and B = dry weight of anion resin, g. 2. Report 2.1 Report the average of the capacities for the three tests and the effluent conductivity endpoint used. 24. Precision and Bias 24.1 Precision See 15.1. 24.2 Bias See 15.2. 25. Keywords 25.1 floc; ion exchange; powdered resin ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentioned in this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the risk of infringement of such rights, are entirely their own responsibility. This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years and if not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standards and should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of the responsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you should make your views known to the ASTM Committee on Standards, at the address shown below. This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the above address or at 610-82-9585 (phone), 610-82-9555 (fax), or service@astm.org (e-mail); or through the ASTM website (www.astm.org). 5