Determination of Methylmercury Levels in Mercurycontaminated. Soils from Oak Ridge TN by Cold Vapor Generation

Similar documents
Using FIMS to Determine Mercury Content in Sewage Sludge, Sediment and Soil Samples

State of the art of mercury speciation analysis

Test Method: CPSC-CH-E

atomic absorption spectroscopy general can be portable and used in-situ preserves sample simpler and less expensive

Prof. Dr. Biljana Škrbić, Jelena Živančev

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB5009.

GRADUATE UNIVERSITY SCIENCE AND TECHNOLOGY TRINH THI THUY. Major: Analytical Chemistry Code: SUMARY OF DOCTORAL THESIS IN CHEMISTRY

DISCLAIMER: This method:

A Comparison of Three Methods for Arsenic Speciation in Biological Tissues. May Nguyen Brooks Rand Labs Seattle, WA

ICP-OES Application Note Number 35

Enhancing the productivity of food sample analysis with the Agilent 7700x ICP-MS

Mercury, total-in-sediment, atomic absorption spectrophotometry, nameless, direct

A Comparison of Arsenic Speciation

Rapid Analytical Methods for Determination of Actinides

J. Serb. Chem. Soc. 78 (10) S117 S126 (2013) Supplementary material. SUPPLEMENTARY MATERIAL TO Analytical methods for arsenic speciation analysis

Innovative. Intuitive. Concentration (ppb) R = Versatile. Hydra II C Mercury Analyzer

Dartmouth Trace Element Analysis Core: Lab methods

METHOD SCOPE AND APPLICATION

UNIVERSITI SAINS MALAYSIA. Second Semester Examination Academic Session 2004/2005. March KAA 502 Atomic Spectroscopy.

Accurate elemental speciation by isotope dilution mass spectrometry with hyphenated techniques

Application of Selenium Speciation Analysis to Elucidate Limitations with Accepted Total Selenium Methods

Today s Agilent Solutions for Determining Heavy Metals in Food using Atomic Spectroscopy

Authors: C. Derrick Quarles, Jr. *, Patrick Sullivan, M. Paul Field, Hwan Kim, and Daniel R. Wiederin

PROCEDURES. Pharmacopeial Forum 2 Vol. 36(1) [Jan. Feb. 2009]

Application of a selective extraction method. for methylmercury compound specific stable. isotope analysis (MeHg CSIA) in biological.

Detection of Mercury(II) and Lead(II) with Graphene Oxide- Based Biosensors

PRINCIPLE OF ICP- AES

Handbook of Inductively Coupled Plasma Spectrometry

Basic Digestion Principles

Supplementary Materials to. Soil Chemistry Group, Institute of Biogeochemistry and Pollutant Dynamics, CHN, ETH Zurich, 8092 Zurich, Switzerland 2

á233ñ ELEMENTAL IMPURITIES PROCEDURES

Biogeochemical controls on Hg transformations at a contaminated site: The role of dissolved organic matter and redox gradients

Rapid determination of five arsenic species in polished rice using HPLC-ICP-MS

Key Analytical Issues: Sample Preparation, Interferences and Variability. Tim Shelbourn, Eli Lilly and Company

Examples of Method Validation Studies Conducted in Different Economies

BATTERY INDUSTRY STANDARD ANALYTICAL METHOD

Title Revision No date DETERMINATION OF HEAVY METALS (ARSENIC, CADMIUM, LEAD AND MERCURY) IN COSMETIC PRODUCTS

Pharmacopeial Forum Vol. 36(1) [Jan. Feb. 2010] 1

Simple, reliable analysis of high matrix samples according to US EPA Method 6020A using the Agilent 7700x/7800 ICP-MS

Microwave-assisted determination of total mercury and methylmercury in sediment and porewater

Hydride Generation for the Determination of As, Sb, Se and Bi Using the Teledyne Leeman Lab s Prodigy 7 ICP-OES

Fundamentals of the ICP-MS Technique and How to Resolve Issues for Pharmaceutical Materials (In 20 Minutes) Tim Shelbourn, Eli Lilly and Company

TECHNICAL PROGRESS REPORT. Date submitted: January 18, Principal Investigators: Leonel E. Lagos, Ph.D., PMP David Roelant, Ph.D.

Determination of Pb, Cd, Cr and Ni in Grains Based on Four Chinese National Methods via Zeeman GFAAS

Laboratory 101: A Guide to Understanding your Testing Laboratory

Intercomparison of Extraction and Analytical Techniques for Inorganic Arsenic in Seaweed

The. Family of Mercury Analyzers. Hydra II AA Atomic Absorption Detection Liquid Samples

Elemental analysis of river sediment using the Agilent 4200 MP-AES

110 Lowell Rd Hudson, NH USA Tel:

Schedule. Draft Section of Lab Report Monday 6pm (Jan 27) Summary of Paper 2 Monday 2pm (Feb 3)

RAPID AND LOW-COST DETERMINATION OF HEAVY METALS IN SOIL USING AN X-RAY PORTABLE INSTRUMENT

Nitric Oxide Assay Kit

Not Just for Paint Chips Anymore. High Throughput, Open Vessel Microwave Digestion of Matrices Requiring Moderate Conditions

Product Descriptions and Offerings

Determination of major, minor and trace elements in rice fl our using the 4200 Microwave Plasma- Atomic Emission Spectrometer (MP-AES) Authors

DRAFT EAST AFRICAN STANDARD

The ultratrace determination of iodine 129 in aqueous samples using the 7700x ICP-MS with oxygen reaction mode

Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry

Analysis of domestic sludge using the Agilent 4200 MP-AES

U.S. EPA SW-846 Method 6010C using the Prodigy High Dispersion ICP

Annex B: Monitoring methods, accuracy, detection limits and precision

ICP-MS-based characterization of inorganic nanoparticles sample

9/13/10. Each spectral line is characteristic of an individual energy transition

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Appendix II- Bioanalytical Method Development and Validation

METHOD 7060A ARSENIC (ATOMIC ABSORPTION, FURNACE TECHNIQUE)

METHOD 9210 POTENTIOMETRIC DETERMINATION OF NITRATE IN AQUEOUS SAMPLES WITH ION-SELECTIVE ELECTRODE

LAMBTON SCIENTIFIC (A Division of Technical Chemical Services Inc.)

Analysis of high matrix samples using argon gas dilution with the Thermo Scientific icap RQ ICP-MS

Determination of Nutrients. Determination of total phosphorus. Extraktion with aqua regia, reflux method. Introduction

Detection of engineered cerium oxide nanoparticles in soils

Structural effects on catalytic activity of carbon-supported magnetite. nanocomposites in heterogeneous Fenton-like reactions

Low Level Detection of Priority Inorganic Pollutants in Water. Anthony Neumann, MSc Darren Crichton, BSc

LEAD(II) AND COBALT(III) HEPTHYLDITHIOCARBAMATES AS NEW COFLOTATION REAGENTS FOR PRECONCENTRATION OF CADMIUM BEFORE ITS ETAAS DETERMINATION

Trace Analysis of Hexavalent Chromium using IC-ICP-DRC-MS

Supporting Information Late Permian Extinction (LPE) samples from Meishan (China) and Buchanan Lake (Canada)

The Agilent 7700x ICP-MS Advantage for Drinking Water Analysis

METHOD 7196A CHROMIUM, HEXAVALENT (COLORIMETRIC)

International Journal of Applied Science and Technology Vol. 7, No. 4, December 2017

Sodium Chloride - Analytical Standard

Atomic Absorption & Atomic Fluorescence Spectrometry

Atomic Absorption Spectroscopy

Multi-Element Analysis of Petroleum Crude Oils using an Agilent 7900 ICP-MS

Sample Analysis Design. Solution Mode

Analytical Approaches to Arsenic

Jo Marie Cook Bureau of Chemical Residue Laboratories

S.K. Sahoo 1 *, Z.S. Zunic 2, R. Kritsananuwat 1, H. Arae 1 and S. Mishra 1

Effect of Oxygenation on Speciation, Behavior, and Fate of Chromium in Estuarine Sediments

7. Stability indicating analytical method development and validation of Ramipril and Amlodipine in capsule dosage form by HPLC.

Appendix: Laboratory Testing Methods

ab83360 Ammonia Assay Kit

ENVIRONMENTAL FACTORS IMPACTING THE FORMATION AND KINETICS OF FE(II) LAYERED HYDROXIDES ON MINERALS AND SOILS. Autumn Nichole Starcher

STANDARD OPERATING PROCEDURE AQ-1 SEQUENTIAL EXTRACTION OF METALS

China Soil Pollution Survey: Elemental Analysis of Soil and Sediment Digests by ICP-MS

About OMICS Group Conferences

INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY

The Determination of Toxic, Trace, and Essential Elements in Food Matrices using THGA Coupled with Longitudinal Zeeman Background Correction

AUTOMATED ONLINE IDENTIFICATION AND MONITORING OF IMPURITIES IN GASES

Basic and Application Inductively coupled plasma mass spectrometry (ICPMS)

Determination of Iron by Dispersive Liquid-Liquid Microextraction Procedure in Environmental Samples

Transcription:

Determination of Methylmercury Levels in Mercurycontaminated Soils from Oak Ridge TN by Cold Vapor Generation Zikri Arslan Department of Chemistry, Physics & Atmospheric Sciences Jackson State University NEMC 2018 August 5 10, 2018 New Orleans, LA

Mercury Released into the atmosphere from natural sources, such as volcanic eruptions and ocean emissions, as well as from anthropogenic sources Distributed throughout the environment in various inorganic and organic forms, including elemental (Hg 0 ), mercurous (Hg 2+ ), mercuric (Hg 2+ ) and alkylated compounds (methylmercury and ethylmercury). Strong neurotoxin impacting the central and peripheral nervous system. Organomercury species bioaccumulate in many different environments. Mineral cinnabar (HgS) is the most insoluble (4.65 10-25 g/l at 25 C) form. HgO and HgCl 2 are relatively soluble Hg species in water, with solubilities of 0.051 g/l at 25 C and 69 g/l at 20 C, respectively.

o Methylmercury (CH 3 Hg) is the most toxic form of mercury that bioaccumulates compared to other forms of mercury. o Impairs the central nervous system, as well as genetic and enzymatic information. o CH 3 Hg represents the predominant form of mercury in the aquatic food chain. Methylmercury

Methods for Mercury Determination Gas Chromatography (GC) Volatilization of analyte and detection via GC. Westoo s method is popular for sample prep to determine organic mercury species. HPLC Preferred over GC because of no volatilization step. Column preconcentration is still necessary. Reversed-phase HPLC is preferred for organomercury detection due to hydrophobic stationary phase, ideal for organic compound detection. Cold vapor generation (CVG) Ideal for trace Hg analysis Allows speciation of Hg. Popular for determination of Hg in blood, hair and urine. ICP-MS Favored for isotopic Hg determinations Low LOD and multi-sample analysis in short amount of time.

Coupled Methods for Mercury Determination Cold Vapor Generation Atomic Fluorescence Spectroscopy (CVG-AFS) Cold Vapor Generation Atomic Absorption Spectroscopy (CVG-AAS) Gas Chromatography -Atomic Fluorescence Spectroscopy (GC-AFS) HPLC-Cold vapor generation Atomic Absorption Spectroscopy (HPLC-CVG- AAS) Cold Vapor Generation Electrothermal Atomic Absorption Spectroscopy CV- ETAAS Cold Vapor generation - Optical Emission Spectrometry (CVG-ICP-OES) Microwave Induced Plasma Atomic Emission Spectroscopy (MIP-AES) HPLC Inductively Coupled Plasma Mass Spectrometry (HPLC-ICP-MS) Gac chromatography Inductively Coupled Plasma Mass Spectrometry (GC- ICP-IDMS)

Legacy Hg Contamination in Oak Ridge, TN In 1960 s, elemental Hg was used at Y-12 National Security Facility for manufacturing components of nuclear weapons. It is estimated that 350 tons of Hg was released to environment. Hg distributed through run-off by the East Fork Poplar Creek (EFPC) which ran through the Y-12 complex, flowing into the surrounding community and terminating at the Clinch River. Mercury contaminated soil from the Y-12 National Security Complex. Adopted from the Knoxville News Sentinel.

Statement of Problem Through remedial actions over the last 25 years, Hg concentrations and fluxes have been reduced, but Hg levels in water at the Y-12 Complex boundary continue to exceed both the regulatory limit (51 ng/l) and the remediation goal (200 µg/l) (Brooks and Southworth 2011). Commensurate reductions in the fish tissue concentrations (to achieve the EPA criteria of 0.3 µg/g) have not been observed (Peterson et al. 2011).

Hypothesis Mercury contaminated soil from the Y- 12 Complex. Adopted from the Knoxville News Sentinel. Methylmercury is water-soluble and thus could directly affect contamination in water and wildlife. It is hypothesized that Hg-contaminated soils in Oak Ridge TN contain significant levels of methylmercury that is responsible for elevated Hg contamination in soil and water.

Objectives To develop a procedure for selective separation and determination of trace amounts of methylmercury in Hg-contaminated soils. (1) Selective extraction of methylmercury from top soil samples. (2) Eliminate inorganic mercury from soil extracts. (3) Quantify trace methylmercury in soils using cold vapor generation.

Results: Total Mercury Levels Total Hg analysis were made by acid digestion of the soils. About 0.1 g soil samples (n=3) was digested on a Graphite Digestion Block at 140 o C in 5 ml HNO 3 and then treated with H 2 O 2 to oxidize organic material. Montana soil (SRM 2710) and 20 Domestic Sludge (SRM 2781) from 0 National Institute of Standards and S 1 S 2 S 3 S 4 S 5 S 6 S 7 S 8 S 9 S 10 Technology (NIST, Gaithersburg, MD) Floodplain soils were used for verification of total mercury analysis. ICP-MS analysis showed that contaminated top soil contained about 57 to 95 mg/kg Hg. Total Hg concentration (µg/g) 100 80 60 40

Selective extraction: Sample Preparation Extraction of CH 3 Hg from soil matrix is carried with template soils collected from Biloxi, MS. They were ground and sieved through 0.25 mm apertures. Samples were analyzed by ICP-MS for Hg content before utilizing in any experimental work. Samples of template soils (0.5 g) were contaminated with 0.2 ml of 100 µg/ml Hg(II) or CH 3 HgCl. Dried at room temperature for at least 48h to simulate the soil matrix from Oak Ridge, TN. 20 µg Hg or CH 3 HgCl spiked into 0.5 g soil (40 mg/kg)

Extraction Extraction with HCl and HNO 3 was attempted for selective extraction of MeHg from the soils. Extractions were performed via shaking of soil suspensions up to 24 h in HCl or HNO 3. Similar suspensions were subjected to ultrasounds using a sonic dismembrator equipped with Titanium probe for time intervals up to 6 minutes.

Effect of shaking HCl extraction In-Hg was extracted substantially in dilute HCl with shaking. However, it was not extracted fully within 24-h of shaking in HNO 3. MeHg was extracted from soils in 5% HCl within 3-h shaking. HNO 3 extraction Spiked MeHg was extracted in HNO 3 in 1 h of shaking into solution. In-Hg extraction was minimal in HNO 3.

Effect of ultrasounds HCl extraction Ultrasound sonication in HCl and HNO 3 yielded similar results with shaking. HNO 3 extraction Extraction was much faster. In 3 min sonication, all MeHg extracted into solution with 5% HNO 3.

More optimization needed for removal of extracted Hg(II) Coprecipitation was attempted to remove residual Hg(II) from soil extracts Coprecipitating agents: bismuth (III), lanthanum (III), iron (III) and ammonium sulfide Complexing agents: L-cysteine and thiourea Precipitation of 100 ppb Hg(II) or CH 3 HgCl was made in 1000 ppm La(III), Bi(III) or Fe(III) with or without L-cysteine and thiourea. Metal hydroxides were precipitated with triethylamine (TEA) 100 µl TEA 100 ppb Hg(II) or CH 3 HgCl + 1000 ppm La(III), Bi(III) or Fe(III) Separate coprecipitations were made with ammonium sulfide, (NH 4 ) 2 S. Hg or MeHg by ICP-MS

Coprecipitation trials without ligands 35 Matrix/Precipitant Recovery (%) MeHg Hg(II) 1000 µg/ml La(III) 2.7 ± 1.2 7.6 ± 0.4 1000 µg/ml Bi(III) 6.3 ± 1.9 5.8 ± 2.0 1000 µg/m Fe(III) 8.8 ± 1.0 22.8 ± 5.2 Fe(III) removed the most Hg(II) from solution without impacting CH 3 HgCl concentration. Coprecipitation of Hg(II) with Bi(OH) 3 and La(OH) 3 provided very little Hg(II) recovery. Coprecipitation rate (%) 30 25 20 15 10 5 0 1000 µg/ml La(III) 1000 µg/ml Bi(III) 1000 µg/m Fe(III) MeHg Hg(II)

Coprecipitations with Ligands Thiourea and L-cysteine were made to 0.1% (m/v) in 2 ml solution of 100 μg/l CH 3 HgCl or Hg(II) and 1000 μg/ml La(III), Bi(III) or Fe(III). The contents were precipitated with 0.2 ml TEA. Matrix/precipitant Recovery (%) MeHg Hg 0.1% L-cysteine 2.5 ± 0.7 3.1 ± 0.6 1000 μg/ml La(III) + 0.1% L- cysteine 11.6 ± 3.8 97.5 ± 14 1000 μg/ml Bi(III) + 0.1% L-cysteine 1.8 ± 0.7 5.4 ± 0.8 1000 μg/ml Fe(III) + 0.1% L- cysteine 7.6 ± 3.5 56.3 ± 7.2 0.1% Thiourea 12.8 ± 1.8 3.2 ± 2.2 1000 μg/ml La(III) + 0.1% Thiourea 41.1 ± 2.8 23.1 ± 1.7 1000 μg/ml Bi(III) + 0.1% Thiourea 67.2 ± 1.0 26.1 ± 4.2 1000 μg/ml Fe(III) + 0.1% Thiourea 24.8 ± 9.1 64.4 ± 4.2 0.005 M Ammonium sulfide* 102 ± 3 3.3 ± 1.9

Coprecipitations with Ligands 120 0.1% L-cysteine 100 0.1% Thiourea Coprecipitation rate (%) 100 80 60 40 La(III) + 0.1% L-cysteine Bi(III) + 0.1% L-cysteine Fe(III) + 0.1% L-cysteine Coprecipitation rate (%) 80 60 40 La(III) + 0.1% Thiourea Bi(III) + 0.1% Thiourea Fe(III) + 0.1% Thiourea 20 20 0 MeHg Hg(II) 0 MeHg Hg (II) La(III) + L-cysteine yielded the most effective for separation of CH 3 Hg from Hg(II). However, CH 3 Hg concentration in solution was reduced by about 12%. Thiourea gave very sporadic recoveries with Fe(III), Bi(III) and La(III). Highest and most selective precipitation enhancement being with that of Bi(III).

Coprecipitation with Ammonium Sulfide Attempts were made to selectively remove Hg(II) from soil with ammonium sulfide, (NH 4 ) 2 S. 25 to 30 μl of 0.35 M (NH 4 ) 2 S was added to 2 ml test solutions that contained 100 μg/l CH 3 Hg or Hg(II). After centrifugation, supernatant was analyzed by ICP-MS because HgS is very insoluble, even in concentrated acids. Recovery of MeHg was quantitative. Hg(II) was effectively eliminated. Remained Hg conc. in solution (%) 100 80 60 40 20 0 MeHg Hg(II) Hg or MeHg by ICP-MS 25 µl (NH 4 ) 2 S 100 ppb Hg(II) or CH 3 HgCl

Optimization of cold vapor generation Cold vapor generation manifold and ICP-MS instrument for determination of CH 3 Hg

Examining Acid Concentration in CVG System For both CH 3 HgCl and Hg(II), CVG signals increased with HNO 3 concentration, and gained consistency at around 4% HNO 3. This is an indication that no modifications need to be done to mercury suspensions prior to determination with CVG-ICP-MS. SnCl 2 did not affect CH 3 Hg at all, but performed similarly to NaBH 4 for vapor generation from Hg(II).

Examining reducing agent in CVG System NaBH 4 and SnCl 2 were examined on Hg(II) and CH 3 HgCl in 5% (v/v) HNO 3, There was no notable vapor generation of CH 3 HgCl, and none at all proceeding 3% of SnCl 2, whereas Hg(II) signals showed a steady pattern at 0.5% (m/v) SnCl 2. 0.5 and 1% (m/v) NaBH 4 gave max readings for both CH 3 HgCl and Hg(II). Signals decreased with increasing NaBH 4 levels which generates excessive H 2 that changed sampling position in the plasma.

Interference studies for (NH 4 ) 2 S and La(III) + L-cysteine When compared to CH 3 HgCl in 5% HNO 3 with 1% NaBH 4 : La(III) + L-cysteine showed no significnat interference on MeHg CVG system. Ammonium sulfide showed some signal depression, but it was not significant.

Calibration curves Calibration curves constructed with CH 3 HgCl solutions prepared in 5% HNO 3 with La(III) + L- cysteine and 0.005 M (NH 4 ) 2 S additives. La(III) + L-cysteine and (NH 4 ) 2 S media showed similar calibration slopes to that of MeHg solutions in 5% HNO 3. 1000000 450000 1000000 900000 800000 y = 86326x + 9040.9 R² = 0.9997 400000 350000 y = 42282x + 1758.6 R² = 0.9995 900000 800000 y = 86326x + 9040.9 R² = 0.9997 202 Hg signal (cps) 700000 600000 500000 400000 300000 200000 100000 MeHg in 5%HNO3 y = 81226x + 2398.6 R² = 0.9957 y = 83971x + 3082.9 R² = 0.9992 MeHg + La(III) + 0.1% L-cysteine MeHg + 0.005M (NH4)2S 201 Hg signal (cps) 300000 250000 200000 150000 100000 50000 y = 38496x + 2468.5 R² = 0.9997 y = 39791x - 2981.8 R² = 0.9993 MeHg in 5%HNO3 MeHg + La(III) + 0.1% L-cysteine MeHg + 0.005M (NH4)2S 202 Hg signal (cps) 700000 600000 500000 400000 300000 200000 100000 MeHg in 5%HNO3 y = 81226x + 2398.6 R² = 0.9957 y = 83971x + 3082.9 R² = 0.9992 MeHg + La(III) + 0.1% L-cysteine MeHg + 0.005M (NH4)2S 0 0 2 4 6 8 10 12 MeHg concentration (µg/l) 0 0 2 4 6 8 10 12 MeHg concentration (µg/l) 0 0 2 4 6 8 10 12 MeHg concentration (µg/l)

The highest LODs were from La(III) + L-cysteine system due to the high background blanks. LODs for ammonium sulfide were similar to those with 5% HNO 3. Limits of detection Medium LOD (µg/l) 200 Hg 201 Hg 202 Hg 5% HNO 3 0.082 0.09 0.085 La (III) + L-cysteine 0.41 0.38 0.42 Ammonium sulfide 0.12 0.1 0.1 1000000 450000 1000000 900000 800000 y = 86326x + 9040.9 R² = 0.9997 400000 350000 y = 42282x + 1758.6 R² = 0.9995 900000 800000 y = 86326x + 9040.9 R² = 0.9997 202 Hg signal (cps) 700000 600000 500000 400000 300000 200000 100000 MeHg in 5%HNO3 y = 81226x + 2398.6 R² = 0.9957 y = 83971x + 3082.9 R² = 0.9992 MeHg + La(III) + 0.1% L-cysteine MeHg + 0.005M (NH4)2S 201 Hg signal (cps) 300000 250000 200000 150000 100000 50000 y = 38496x + 2468.5 R² = 0.9997 y = 39791x - 2981.8 R² = 0.9993 MeHg in 5%HNO3 MeHg + La(III) + 0.1% L-cysteine MeHg + 0.005M (NH4)2S 202 Hg signal (cps) 700000 600000 500000 400000 300000 200000 100000 MeHg in 5%HNO3 y = 81226x + 2398.6 R² = 0.9957 y = 83971x + 3082.9 R² = 0.9992 MeHg + La(III) + 0.1% L-cysteine MeHg + 0.005M (NH4)2S 0 0 2 4 6 8 10 12 MeHg concentration (µg/l) 0 0 2 4 6 8 10 12 MeHg concentration (µg/l) 0 0 2 4 6 8 10 12 MeHg concentration (µg/l)

Method validation Sample CH 3 Hg concentration (ng/g) 200 Hg 201 Hg 202 Hg SQC1238 13.0 ± 3 13.2 ± 3 12.8 ± 4 ERM CC580 81 ± 7 79 ± 8 80 ± 4 Certified value (ng/g) 10.00 ± 3 75 ± 4 Reference materials SQC1238 (methylmercury sediment) CH 3 Hg = 0.01 ± 0.00291 µg/g ERM CC580 (estuarine sediment) Total Hg = 132 ± 4 µg/g and CH 3 Hg = 0.075 ± 0.004 µg/g Samples (0.2 g for SQC1238 and 0.1 g for ERM-C580) were agitated via ultrasound for 3 min in 5% HNO 3 (5 ml). 2 ml of the extract was then taken and treated with 30 µl of 0.35 M (NH 4 ) 2 S for removal of Hg(II). Contents were centrifuged at 12,000 rpm for 20 min, then transferred to 2-mL microcentrifuge tubes and analyzed by CVG-ICP-MS.

Analysis of soils for MeHg Soils from Oak Ridge TN were processed with optimized method, and analyzed along with SRMs. CH 3 Hg levels ranged from 0.030 to 0.051 µg/g. CH 3 Hg distribution in the floodplain soils were much lower compared with Hg(II) or total Hg levels. CH 3 Hg concentrations are within the proximity of regulatory limit (0.051 µg/g). Sample CH 3 Hg concentration (µg/g) 200 Hg 201 Hg 202 Hg Soil 1 0.043 ± 0.006 0.043 ± 0.006 0.045 ± 0.006 Soil 2 0.040 ±0.008 0.040 ± 0.008 0.041 ± 0.008 Soil 3 0.040 ± 0.012 0.041 ± 0.013 0.040 ± 0.013 Soil 4 0.032 ± 0.003 0.032 ± 0.004 0.033 ± 0.04 Soil 5 0.032 ± 0.009 0.032 ±0.009 0.033 ± 0.009 Soil 6 0.050 ± 0.01 0.051 ± 0.012 0.051 ± 0.015 Soil 7 0.046 ± 0.005 0.047 ± 0.006 0.047 ± 0.005 Soil 8 0.029 ± 0.002 0.030 ± 0.002 0.031 ±0.0013 Soil 9 0.033 ± 0.009 0.032 ± 0.008 0.033 ± 0.008 Soil 10 0.042 ± 0.011 0.043 ± 0.012 0.042 ± 0.012

Conclusions The method developed for selective extraction of MeHg from contaminated sediments provides rapid extraction and high selectivity with effective removal of Hg(II) prior to determination. Ultrasounds extraction in HNO 3 and further sample treatment with ammonium sulfide precipitation allowed the highest selectivity for accurate determination of CH 3 Hg with cold vapor generation. Results show that there is MeHg in the contaminated soil from the Y-12 National security complex. The distribution of MeHg in the topsoil in the contaminated regions are at the threshold of regulatory limits of 0.051 µg/g.

Acknowledgements Louis-Stokes Mississippi Alliance for Minority Participation for funding my research at Jackson State University. Grant # NSF HRD-1500317 DOE-EM-MSIPP Program at JSU through Savannah River Nuclear Solutions (SRNS) Contract # 000029143 NIH-RCMI-CEH at JSU Grant # NIMHDG12MD00758