Development of miniaturized, spectroscopically assisted Penning gauges for fractional helium and hydrogen neutral pressure measurements

Similar documents
Magnetic Flux Surface Measurements at Wendelstein 7-X

Temporal Evolution of Temperature and Argon Impurity Density Profiles Observed by X-ray Imaging Spectrometer Measurements at Wendelstein 7-X

In situ wavelength calibration of the edge CXS spectrometers on JET

Power Balance Analysis of Wendelstein 7-X Plasmas Using Profile Diagnostics

The emissivity of W coatings deposited on carbon materials for fusion applications

Modelling and Analysis of the JET EP2 Neutral Beam Full Energy Ion Dump Curved End Plate

Electron energy distribution function in the divertor region of the COMPASS tokamak during neutral beam injection heating

Integrated equilibrium reconstruction and MHD stability analysis of tokamak plasmas in the EU-IM platform

Central Solenoid Winding Pack Design

EUROFUSION WPJET1-PR(16) CG Albert et al.

Turbulent Transport Analysis of JET H-mode and Hybrid Plasmas using QuaLiKiz, TGLF and GLF23

Comparative Transport Analysis of JET and JT-60U Discharges

Multiscale modelling of sheath physics in edge transport codes

Measurements of Deuterium Retention and Surface Elemental Composition with Double Pulse Laser Induced Breakdown Spectroscopy

Modelling of prompt deposition of tungsten under fusion relevant conditions

Multi-Machine Experiments to Study the Parametric Dependences of Momentum Transport

Neutron Emission Spectroscopy Measurements with a Single Crystal Diamond Detector at JET

Simulation of PHA Soft X-Ray Spectra Expected from W7-X

CFD simulation of the magnetohydrodynamic flow inside the WCLL breeding blanket module

Thermo-mechanical analyses and ways of optimization of the helium cooled DEMO First Wall under RCC-MRx rules

Application of the ECRH radiation for plasma diagnostics in Wendelstein 7-X

Concept of C/O Monitor diagnostic for stellaratorw7-x

Cesium Dynamics and H - Density in the Extended Boundary Layer of Negative Hydrogen Ion Sources for Fusion

Towards powerful negative ion beams at the test facility ELISE for the ITER and DEMO NBI systems

Modelling of Carbon Erosion and Deposition in the Divertor of JET

Deuterium Balmer/Stark spectroscopy and impurity profiles: first results from mirror-link divertor spectroscopy system on the JET ITER-like wall

Power Deposition Measurements in Deuterium and Helium Discharges in JET MKIIGB Divertor by IR-Thermography

Preliminary system modeling for the EUROfusion Water Cooled Lithium Lead blanket

STEADY-STATE EXHAUST OF HELIUM ASH IN THE W-SHAPED DIVERTOR OF JT-60U

L-mode filament characteristics on MAST as a function of plasma current measured using visible imaging

Divertor configuration with two nearby poloidal field nulls: modelling and experiments for EAST and JET tokamaks

First Observation of ELM Suppression by Magnetic Perturbations in ASDEX Upgrade and Comparison to DIII-D Matched-Shape Plasmas

L-Mode and Inter-ELM Divertor Particle and Heat Flux Width Scaling on MAST

Divertor Heat Flux Reduction and Detachment in NSTX

On the Design Aspects Affecting Performance of GEM based Detector Development for Plasma Diagnostics

Development of MPPC-based detectors for high count rate DT campaigns at JET

Tandem Collimators System

D- Charge Exchange Ionizer for the JINR Polarized Ion Source POLARIS

Observation of modes at frequencies above the Alfvén frequency in JET

and expectations for the future

A Faster Way to Fusion

The role of statistical noise in edge plasma transport codes based on kinetic Monte Carlo solvers for neutrals: an analogy with turbulent fluctuations

Simulation of Double-Null Divertor Plasmas with the UEDGE Code

POLARIZED DEUTERONS AT THE NUCLOTRON 1

The physics of the heat flux narrow decay length in the TCV scrape-off layer: experiments and simulations

MHD limits and plasma response in high beta hybrid operations in ASDEX Upgrade

Plasma Spectroscopy in ISTTOK

Study of DC Cylindrical Magnetron by Langmuir Probe

Evaluation of First Wall Heat Fluxes Due to Magnetic Perturbations for a Range of ITER Scenarios

Thomson Scattering with laser intra-cavity multipass system to study fast changing structures in fusion plasma

Evidence for enhanced main chamber wall plasma loads in JET ITER-like Wall at high radiated fraction

PoS(ECPD2015)109. Planned Active Spectroscopy in the Neutral Beam Injectors of W7-X

Excitation of Alfvén eigenmodes with sub-alfvénic neutral beam ions in JET and DIII-D plasmas

Recent progress towards a functional model for filamentary SOL transport

Tailoring the charged particle fluxes across the target surface of Magnum-PSI

Introduction to Fusion Physics

TARGET PLATE CONDITIONS DURING STOCHASTIC BOUNDARY OPERATION ON DIII D

D.J. Schlossberg, D.J. Battaglia, M.W. Bongard, R.J. Fonck, A.J. Redd. University of Wisconsin - Madison 1500 Engineering Drive Madison, WI 53706

Scaling of divertor heat flux profile widths in DIII-D

Non-inductive plasma startup and current profile modification in Pegasus spherical torus discharges

Nuclear Analysis of the HCLL Blanket Concept for the European DEMO Using the TRIPOLI-4 Monte Carlo Code

Study of Impacts on Tritium Breeding Ratio of a Fusion DEMO Reactor

Flux-driven multi-channel simulations with the quasilinear gyrokinetic tokamak transport model QuaLiKiz

Driving Mechanism of SOL Plasma Flow and Effects on the Divertor Performance in JT-60U

purposes is highly encouraged.

Estimating the plasma flow in a recombining plasma from

Neutron emission spectroscopy of DT plasmas at enhanced energy resolution with diamond detectors

INTRODUCTION TO MAGNETIC NUCLEAR FUSION

High Temperature Superconductors for Fusion at the Swiss Plasma Center

Plasma response of magnetic perturbation at the edge: Comparisons between measurements and 3D MHD models

Power loads to misaligned edges in COMPASS

Figure 1, Schematic Illustrating the Physics of Operation of a Single-Stage Hall 4

Full Wave Propagation Modelling in View to Integrated ICRH Wave Coupling/RF Sheaths Modelling

Effect of non-axisymmetric magnetic perturbations on divertor heat and particle flux profiles

Confinement of toroidal non-neutral plasma in Proto-RT

Enhancement of an IEC Device with a Helicon Ion Source for Helium-3 Fusion

A novel helicon plasma source for negative ion beams for fusion

Introduction to Nuclear Fusion. Prof. Dr. Yong-Su Na

D.J. Schlossberg, D.J. Battaglia, M.W. Bongard, R.J. Fonck, A.J. Redd. University of Wisconsin - Madison 1500 Engineering Drive Madison, WI 53706

Dust collected in MAST and in Tore Supra. Nanoparticle growth in laboratory plasmas

1 AT/P5-05. Institute of Applied Physics, National Academy of Sciences of Ukraine, Sumy, Ukraine

Simulation of Electron Behavior in PIG Ion Source for 9 MeV Cyclotron X. J. Mu 1, M. Ghergherehchi 1a, Y.H. Yeon 1, J.S. Chai 1

Improved EDGE2D-EIRENE Simulations of JET ITER-like Wall L-mode Discharges Utilising Poloidal VUV/visible Spectral Emission Profiles

Bolometry. H. Kroegler Assciazione Euratom-ENEA sulla Fusione, Frascati (Italy)

FAR SCRAPE-OFF LAYER AND NEAR WALL PLASMA STUDIES IN DIII D

(Tandem Collimators for the Tangential GammaRay Spectrometer - KM6T-TC)

Ion Cyclotron Emission from JET D-T Plasmas

Influence of Impurity Seeding on ELM Behaviour and Edge Pedestal in ELMy H-Mode Discharges

Physics of the detached radiative divertor regime in DIII-D

Modelling of the ICRF induced ExB convection in the scrape off layer of ASDEX Upgrade

Confinement of toroidal non-neutral plasma in Proto-RT

JET JET JET EFDA THE JOINT EUROPEAN TORUS A EUROPEAN SUCCESS STORY

L-to-H power threshold comparisons between NBI and RF heated plasmas in NSTX

Improved Plasma Confinement by Ion Bernstein Waves (IBWs) Interacting with Ions in JET

Chapter 23 Electric Potential. Copyright 2009 Pearson Education, Inc.

Plans for a laboratory electron-positron plasma experiment

A novel helicon plasma source for negative ion beams for fusion

Electrical Discharges Characterization of Planar Sputtering System

Scaling of divertor heat flux profile widths in DIII-D

EXD/P3-13. Dependences of the divertor and midplane heat flux widths in NSTX

Transcription:

EUROFUSION WPS1-PR(16) 16145 T Kremeyer et al. Development of miniaturized, spectroscopically assisted Penning gauges for fractional helium and hydrogen neutral pressure measurements Preprint of Paper to be submitted for publication in 21st Topical Conference on High Temperature Plasma Diagnostics 2016 This work has been carried out within the framework of the EUROfusion Consortium and has received funding from the Euratom research and training programme 2014-2018 under grant agreement No 633053. The views and opinions expressed herein do not necessarily reflect those of the European Commission.

This document is intended for publication in the open literature. It is made available on the clear understanding that it may not be further circulated and extracts or references may not be published prior to publication of the original when applicable, or without the consent of the Publications Officer, EUROfusion Programme Management Unit, Culham Science Centre, Abingdon, Oxon, OX14 3DB, UK or e-mail Publications.Officer@euro-fusion.org Enquiries about Copyright and reproduction should be addressed to the Publications Officer, EUROfusion Programme Management Unit, Culham Science Centre, Abingdon, Oxon, OX14 3DB, UK or e-mail Publications.Officer@euro-fusion.org The contents of this preprint and all other EUROfusion Preprints, Reports and Conference Papers are available to view online free at http://www.euro-fusionscipub.org. This site has full search facilities and e-mail alert options. In the JET specific papers the diagrams contained within the PDFs on this site are hyperlinked

Development of miniaturized, spectroscopically assisted Penning gauges for fractional helium and hydrogen neutral pressure measurements K. Flesch 1 and T. Kremeyer 1, O. Schmitz 1, V. Soukhanovskii 3, U. Wenzel 2, the W7- X Team, and NSTX-U Team 1 University of Wisconsin - Madison, Department of Engineering Physics, Madison, WI 53706, USA 2 Max Planck Inst. for Plasma Physics, 17491 Greifswald, Germany 3 Lawrence Livermore National Laboratory, Livermore, CA, USA (Presented XXXXX; received XXXXX; accepted XXXXX; published online XXXXX) Direct measurements of the helium (He) fractional neutral pressure in the neutral gas around fusion devices is challenging because of the small mass difference between the abundant D 2 molecules and the He ash which will be produced by D-T fusion. To study He exhaust, an in-situ Penning gauge system is being developed at UW-Madison that is optimized for good pressure and high spectroscopic sensitivity. Three different anode geometries have been studied regarding their vacuum electrostatic fields, light output, and ion current. The light output of the two new anode configurations are at least one order of magnitude above currently available designs, hence improving the spectroscopic sensitivity at similar total neutral pressure resolution. I. INTRODUCTION In fusion reactors, deuterium-tritium (D-T) plasmas will be heated to ignition and release large amounts of energy. The D-T fusion reaction has a by-product of helium ash, which if not exhausted efficiently enough, can begin to dilute the D-T plasma. To study He exhaust in current plasma devices, vacuum gauges utilizing the Penning trap principle [1] have been used for measurement of total neutral pressure assisted by spectroscopy [1] to resolve D and He. This approach was shown to be a very versatile method for partial pressure measurement of neutral He and molecular D 2, which is challenging because they have almost identical masses. It has been used on plasma devices including TEXTOR, JET and DIII-D [2,3,4]. The measurements on these devices have all been done with large commercial Penning gauges, the Alcatel CF2P, that use permanent magnets to sustain the Penning discharge. This has been shown to be a reliable approach but is limited in time resolution by moderate light output. In addition, these gauges can only be mounted on the outer periphery of the device, so the vacuum time scale defines the measurement quality and interpretation. It is necessary, therefore, to develop a vacuum gauge using the Penning trap principle which can be inserted deep into the vacuum volume for instance directly into the divertor housing in order to obtain full in-situ measurements. To accomplish this, the in-situ gauge must be small enough to be mounted near the divertor and edge regions, which will necessitate it use the inherent external field. The National Spherical Tokamak Experiment-Upgrade (NSTX- U) already has a custom gauge that can make fast total neutral pressure measurements located at various points around the torus [5], which was the starting point for this study. At the same time, we aim on preparing an in-situ fractional neutral pressure measurement inside the island divertor housing of the recently started stellarator Wendelstein 7-X (W7-X) to study the properties of the island divertor. II. INITIAL TEST AT W7-X For W7-X, a commercial Penning gauge, Alcatel CF2P, has been installed on an outboard vacuum flange in the device midplane in order to conduct a generic feasibility test. Helium emission lines were measured down to a base pressure of 10-5 mbar and H α emission lines down to 10-6 mbar with an integration time of 10s. Successful measurement of the total as well as the fractional neutral pressures of He and H was demonstrated with the system at W7-X. The Thorlabs CS175 compact CCD spectrometer that was used features a dispersion range of 500 to 1000 nm with FWHM accuracy < 0.6 nm at 633 nm and a possible integration time between 10 μs to 60 s. The initial test has shown that it is mandatory to improve the time resolution. III. NSTX-U PENNING GAUGE Currently several custom-built Penning gauges are installed on NSTX-U [5]. The design of these gauges is depicted in Fig. 1. It was modified from the Penning gauges used on the Princeton Divertor Experiment (PDX) [6] and has the unique ability to use either a magnetic field from permanent magnets mounted on the cathode plates or the external field generated from the field coils of NSTX-U itself. This allows for the gauge to be located either farther out on the pumping ducts or very close to the divertor and edge regions of the tokamak while still giving accurate neutral pressure measurements. With a bias voltage of 3.12kV, this gauge can operate in a limited range from 1.3x10-4 - 2x10-3 mbar [5]. IV. VACUUM TEST STAND FIG.1. CAD drawing of the modified-pdx gauge in use on NSTX-U

To test different anode designs, an ultra-high vacuum test stand has been set up at UW-Madison. The attainable final pressure of the system is < 3x10-9 mbar with a turbopump volume flow rate of 1050 l/s for H and 1320 l/s for He. The test stand is equipped with a 400 W high voltage power supply ranging from 0 5000 V, a Varian FRG-700 gauge measuring pressure from 1x10-9 mbar up to atmosphere, and a gas inlet system which can supply He and H. The optimized candidate anodes were tested with a magnetic field of 70 mt from a pair of permanent magnets. V. ANODE DESIGNS Three anode designs were tested and are shown conceptually in the left column of Fig. 2 with an actual photograph of the discharge obtained on the right side. Since the optimized gauge must be able to use the external fields of the devices which it is mounted on, the starting point for the optimization process was the modified-pdx gauge design on NSTX-U. This was built and tested on the vacuum test. A discharge was achieved with this design from 1500-2750 V at a pressure of 5.0x10-5 mbar but at higher voltage did not ignite a discharge until above 1.0x10-2 mbar. This anode design has achieved the desired sensitivity to total pressure, but as can be seen in Fig. 2.a, it has very low light output, which limits the time resolution of the spectral analysis. Based on this, two new anodes were designed aiming for better optical access to the Penning discharge and enhanced discharge light altogether. The original NSTX-U configuration was changed to more open designs that allowed for viewing into the cylindrical portion of the gauge where the electrons are trapped and the neutrals are ionized. The first of the new designs attempted to look into middle of the cylinder by taking out a cut and leaving two thin rings 1/8 wide located the same distance away from plates as the cylinder. The schematic for this is in Fig. 2.b with a picture of the discharge. The second design was a thin ring 1/8 wide in the middle in order to see into the discharge from the sides. The schematic for this anode is in Fig. 2.c also with a picture from the discharge. All pictures in Fig. 2 were taken with comparable camera exposure and aperture settings and hence the light emissivity can be compared between the three designs. This visual inspection shows that the two new anode designs are far superior in terms of light emission. The next step is to qualify stable discharge conditions for the ion current measurement which represents the neutral density in the gauge volume. A monotonic increase of the ion current with pressure in the reference chamber must be found to enable calibration and eventual extraction of absolute neutral pressure values. VI. ANODE CURRENT Pressure sweeps in both directions were taken for all three anodes and the ion current at the cathodes was measured. The I(p n ) measurements are shown in Fig. 3. The tube anode generates about a factor of two stronger ion current compared to the ring and double ring anodes. In all three anodes, there are voltages in which the measured current does not increase monotonically with pressure. This could be due to the plasma switching to different discharge regimes or points at which instabilities form [7]. The most significant one was seen with the tube anode at 1500 V in the high 10-3 mbar pressure range. Despite this, it was still possible to find at least one operating voltage where current increased monotonically through the entire pressure sweep and could be feasible for total neutral pressure measurements. Because of the steep ion current curve, the tube anode seems to be the most sensitive design. VII. LIGHT INTENSITY To quantitatively compare the light output of the three anodes, the CCD spectrometer was used. The brightness of four helium lines was compared at the same pressure and integration time. The comparison of the light intensities is shown in Fig. 4. The ring anode as well as the double ring anode are an order of magnitude brighter than the NSTX-U Penning gauge. The double ring anode creates the brightest discharge which can be, depending on the operating anode voltage, about 2.5 times brighter than the discharge of the ring anode. Note that the light output of the NSTX-U gauge is so small, it is not visible on the FIG. 2. Anode design schematics and pictures taken with a 20 MP camera of the NSTX-U anode, double ring anode, and single ring anode. Magnetic field is horizontal for this view. FIG. 3. Measured ion current at the cathode for the NSTX-U anode, double ring anode, and single ring anode.

graph. VIII. VACUUM ELECTRIC FIELD MODELS A simple model of the vacuum electrostatic field for each anode was computed in order to add insight into the experimental results and aid in further optimization. The modelling was done in MATLAB using the finite difference method, and the electric field maps are shown in Fig 5 for all three cases. The model assumes axisymmetry, and the electric field is analyzed in one horizontal plane at the mid-plane of the gauge. Electrons become trapped in the areas where the electric field lines are perpendicular to the magnetic field, which is vertical in that view, due to ExB drifts. The ions, which are much more massive, practically follow the field lines directly to the cathode plates at the top and bottom. It can be seen that the only areas where the electric and magnetic fields are perpendicular for the tube (Fig. 5.a) and single ring (Fig 5.c) anodes are directly inside the anode and at the plane across the exact middle. The electric field strength for the ring anode, though, is much weaker than the tube anode, which leads to the ions moving slower towards the plates and the possibility for more collisions as well as recombination events. This could potentially be the reason for the large increase of light intensity from this anode. The double ring anode shows the interesting feature of having large regions between the rings with perpendicular electric and magnetic fields. This increases the volume where electrons are trapped, which further increases the chances for ionization events. The electric field strength in this center region is weaker than the tube anode, which again means slower ions and the chance for more recombination events and additional enhancement of light emission. This analysis suggests that the new anode designs increase the trapping volume and at the same time reduce the electrical field strength. This can increase the ion dwell time in the trap and enhance the interactions with the neutral gas, which increases the light emission level. pressure measurement. Based on these tests and the models, a new anode will be designed as a double ring anode with wider rings and a thinner gap. This shall maintain the good optical properties of the new anode designs but at the same time make the Penning trap plasma more resilient against the development of plasma modes and instabilities, which prevent a monotonic calibration of current with pressure. Future work also includes testing in different magnetic field strengths, especially above the transition field strength for developing these modes, as well as sensitivity to alignment with the magnetic field. XI. ACKNOWLEDGMENTS This work was funded in part by the Department of Energy under grants DE-SC0012315 and DE-SC0014210 and DE-AC5207NA27344. This work has been carried out within the framework of the EUROfusion Consortium and has received funding from the Euratom research and training programme 2014-2018 under grant agreement No 633053. The views and opinions expressed herein do not necessarily reflect those of the European Commission. 1 F.M. Penning, Physica III, no. 9 (1936). T. Denner, K. H. Finken and G. Mank. Rev. Sci. Instr. 67, 3515 (1996). D. L. Hillis, C. C. Klepper, M. Von Hellermann, J. Ehrenberg, K. H. Finken, G. Mank. Fus. Eng. Des. 34-35 (1997) 347-351 4 M. Wade et al. Phys. Rev. Lett. 74, 2702 (1995). 5 R. Raman, H. W. Kugel, T. Provost, R. Gernhardt, T. R. Jarboe, and M. G. Bell. Rev. Sci. Instr 74, 1900 (2003). 6 H. F. Dylla. Jour. Vacu. Sci & Tech. 20, 119 (1982). 7 P.A. Redhead, Vacuum 38, 8-10 (1988) 2 3 IX. SUMMARY Two different anode designs have been developed that have at least an order of magnitude brighter discharge than the presently available Penning gauges. The existing NSTX-U gauge served as reference, and it was seen that this gauge is the most sensitive to neutral pressure. However the ion current sensitivities of the ring and double ring anode seem feasible for accurate total FIG. 4. Spectral line intensities for specified He emission lines for the three anode designs at various voltages FIG. 5. Vacuum electrostatic field lines and equipotential surfaces for the cylindrical anode, double ring anode, and single ring anode at 2000V. Magnetic field is vertical for this view