Reagents - Install/Replace. Select method/sequence. KF Reagent calibration Running KF titration methods. Running SAC sequences

Similar documents
Electrodes - Connect/Replace. Reagents - Install/Replace. Select method ph electrode calibration. Reagent calibration.

TitraLab 580 and 585. KF Titration Workstations. Reference Manual D21T083

Karl Fischer Volumetric Titration Theory and Practice

Automatic titrators, TitroMatic

Karl-Fischer Titration the method for determining water

From 1 ppm to 100% Karl Fischer water content determination

Easy and reliable KF titrations From 1 ppm to 100%

Chloride, HR, Direct Measurement ISE Method Method g/l to 35 g/l Cl Powder Pillow ISA

Compact Titration Compact Titrator G20. One Click Titration Simple & Dependable

Compact Titration. Compact Titrator G20. One Click Titration Simple & Dependable

Volumetric Measurement Techniques. Technique #1 Use of a Burette. Technique #2 Use of a Pipette. Technique #3 Use of a Volumetric Flask

TitraLab 870. Reference Manual. ph/ep/ip/ec/ise Titration Workstation D21T060

Direct Measurement ISE Method Method to 4.00 mg/l NO 3 N TISAB Solution

Operating Instructions for Ammonium ISE Specifications

USER MANUAL. Aquamax TAN

Semi-automatic titrators PH-Burette. A great ph-meter with integrated burette. Incredible price! Infinite possibilities

NO 500 DIN, NO 500 BNC NO 800 DIN, NO 800 BNC

TitraLab 854 and 856. ph-stat Titration Workstations. Reference Manual D21T054

ION570. Reference Manual. Ion Analyser D21M073

ION570. Reference Manual. Ion Analyser D21M073

Determination of the Equivalent Weight and the K a or K b for a Weak Acid or Base

KEM SET. for FOOD. Salinity. Brix Density Concentration. Acid Value POV. Water Content

Citric Acid Analysis L-6-1. MOISTURE (Karl Fischer)

Acid-Base Titration. Evaluation copy

KEM SET. for Beverage. Gas volume Internal gas pressure Air content Oxygen concentration Inside pressure Density Brix

Titration Workstations

BIOGAS Titration Manager

рн PRO Controller The device is used to control and regulate ph level in hydroponic systems and water preparing units automatically USER MANUAL

Operating Instructions. EasyPlus Titration Easy KFV

INSTRUCTION MANUAL. Type: ORP500 C, ORP500 CD, ORP222 CD, ORP223 CD EN Introduction Helpful Operating Tips. 2

User Manual. Compact Titrator G10S/G20S

ph Probe ReallyEasyData com

Acid-Base Titration. Sample

Karl Fischer Titrator

Our Drop Counter sensor now features housing for two electrode sensors, an anti-twist mechanism, an indicator LED and two cable guides.

Titrex ACT titrators have been designed to simply and precisely satisfy and perform the widest range of potentiometric titrations: acid-base, redox,

Corn Sugar (crude & refined) Analysis F MOISTURE (Karl Fischer)

Advanced Sensor Technologies, Inc. TEL: TOLL FREE: WOW-ASTI ( ) FAX:

Conductometric Titration & Gravimetric Determination of a Precipitate

Waters GPC User Guide and Tutorial for Using the GPC in the Reynolds Research Group 2 nd Edition: April 2012

symphony Reference Electrodes

ph electrode Instruction Manual For use with the RAH-210 & RPH-250

Potentiometric measurement of ph

6 Acid Base Titration

Automatic Potentiometric Titrator

KAM LKF and PKF Karl Fischer Moisture Analyzer. User Manual KFMANUAL An ISO 9001 certified company

Titration Catalog. Systems and Autosampler

QAM-I-111 Operation and Calibration of the Conductivity Meter

Standardizing a Solution of Sodium Hydroxide. Evaluation copy

CHEM Practice to be done before the lab. Experiment 9 Introduction to Volumetric Techniques II. Objectives

425 Jordan Road SOP. No. 10 Rev. No. 1.3 Troy, NY Date: 03/14/2012 Page 1 of 7

Titration of a strong acid with a strong base with Cobra4

Concise laboratory catalogue

TitroLine alpha plus From precise programmable piston burette to fully automatic titration system

Operating Instructions. Titration Excellence Terminal

C = concentration as ppm sulfide V t = volume of titrant at endpoint V s = volume of standard used (10 ml)

Chemistry 3202 Lab 6 Hess s Law 1

Electricity. Electrolysis. Current and the transport of charge DETERMINATION OF THE FARADAY CONSTANT BASIC PRINCIPLES

STANDARD OPERATING PROCEDURE (SOP) FOR ESTIMATION OF DIETARY INTAKE OF SODIUM (DIS) IN 24 HOUR URINE USING ELECTROLYTE ANALYZER

Electrochemistry LEC Potentiometric ph titration (phosphoric acid in a soft drink) What you need: What you can learn about

12.01 Determination of the isoelectric point of an amino acid (glycine)

INTRODUCTION TO ACIDS, BASES AND TITRATION

Experiment C-10 Titration of a Strong Acid and a Strong Base

Easier Titration at any level of complexity: TitroLine alpha plus

Supernatant: The liquid layer lying above the solid layer after a precipitation reaction occurs.

Sample Preparation LCW 909. Total Kjeldahl Nitrogen, TKN NB: NEW! LCW 909 GB

Mobile coulometer for water determination anywhere you want

Acid-Base Titration. Volume NaOH (ml) Figure 1

Tetraphenylborate Method Method to 7.0 mg/l K Powder Pillows

Determination of the K a of a Weak Acid and the K b of a Weak Base from ph Measurements

Basic Equipments and Instruments used in Chemistry laboratory: Balance: It is an instrument for measuring mass.

ph Probe Silver / silver chloride Reads Range / Resolution 95% in 1s Response time 100 PSI Max pressure 60m (197 ft) Max depth 1 99 C

Karl Fischer Titration Of Food : Towards Complete Automation

Chemistry MultiMeasure Sensor PS-2170

Agilent G3212 GC-APCI Source

Related concepts Electrolyte, electrical conductance, specific conductance, ion mobility, ion conductivity, conductometry, volumetry.

ACID-BASE TITRATION (MICROSCALE)

Lab 5 Enthalpy of Solution Formation

Application Determination of isocyanate (NCO-) content

CHEM 334 Quantitative Analysis Laboratory

Supernatant: The liquid layer lying above the solid layer after a precipitation reaction occurs.

Tex-620-J, Determining Chloride and Sulfate Contents in Soil

Simple Operation Manual

Electrodes for ph measurements. - when you need to be sure...

Operating Instructions. EasyPlus Titration Easy ph / Easy Ox / Easy Cl / Easy Pro

Kjeltec 2300 Analyzer Unit

MEASUREMENT: PART II

Conductimetric Titration and Gravimetric Determination of a Precipitate

ph Probe Spear Tip Silver / silver chloride Reads Range / Resolution 95% in 1s Response time 100 PSI Max pressure 60m (197 ft) Max depth

The Synthesis and Analysis of Aspirin

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS International General Certifi cate of Secondary Education

To measure ph s in a variety of solutions and mixtures and to account for the results obtained.

Acid-Base Titration. Computer OBJECTIVES

S ENTEK Unit 6 & 7 Crittall Court, Crittall Drive, Springwood Industrial Estate, Braintree, Essex, CM7 2SE Tel: +44 (0) Fax: +44 (0)

POTENTIOMETRIC TITRATIONS & SOLUBILITY EQUILIBRIA. Background

iworx Sample Lab Experiment GB-2: Membrane Permeability

Common Acids and Bases

GENERAL INSTRUCTIONS GENERAL PREPARATION

Mixtures of Acids and Bases

STANDARD OPERATING PROCEDURE No. 52 STATIC ACID GENERATION (NAG) TEST

Transcription:

Short-For t-form Reminders Reagents - Install/Replace Select method/sequence KF Reagent calibration Running KF titration methods Running SAC sequences Maintenance recommendations Storage recommendations Spare parts & accessories Electrodes and solutions DT080 Printed by Radiometer Analytical SAS 008-09B Short-Form Reminders

Short-Form Reminders

To replace empty reagent bottles, use the bottle exchange procedure Reagents - Install/Replace Form no. Select method or sequence and For a and 3 method XYZ For a sequence Install reagent system. Enter Reagent window. then 3. Press to enter batch no., expiry date then confirm 4. If required, rinse burette Remove a reagent 5. Install reagent bottle and press to flush Run the Rinse procedure in the Burette functions screen. This procedure is required when you no longer wish to use the reagent or replace it by another one.. Enter Reagent window. 3 XYZ then 4 JKL

Bottle exchange: with one of same type and ID. Enter Reagent window 4. Confirm. then 5. Enter batch no. and expiry date of new reagent and confirm 6. Remove bottle 3. Press to select reagent 7. Install new bottle and press to flush and fill Replace reagent: with different type and ID. Enter Reagent window 4. Confirm replace. then 5. 3. Enter batch no. and expiry date 6. Remove old, install new reagent bottle, press to flush DT080 Printed by Radiometer Analytical SAS France 008-09B

Straightforward method selection Select method/sequence Form no. Select method. Enter main menu. Select method from list 3. Confirm

Select sequence. Enter main menu. 3 XYZ then 3. Enter sequence name and confirm 4. Esc Check icons You can run the method You can run the method. However a calibration and/or a reagent bottle exchange must be performed soon Check the reagents for installation or calibration purposes Programming error due to missing parameters DT080 Printed by Radiometer Analytical SAS France 008-09B

Calibrate your reagent KF Reagent calibration Form no. 3 Select reagent. Enter Reagent window. then to select reagent from list 3. Confirm Run. To run the calibration. Enter User ID, if required, and confirm

3. Enter Standard batch number then confirm 4. Rinse electrode(s) and dip in beaker. Check solvent level. Confirm 5. After cell equilibration, inject Standard advised amount into the cell. Confirm 6. Enter Standard amount. Confirm Automatic result display Press to save result View statistics Stop then More tests/end of analysis Resume analysis Emergency stop DT080 Printed by Radiometer Analytical SAS France 008-09B

Run your analyses Running KF titration methods Form no. 4 Run. To run your selected method (*). Enter User ID, if required, and confirm 3(*). Enter Sample ID and confirm 4(*). Rinse electrode(s) and dip in beaker. Check solvent level and confirm 5. After drift determination, inject Sample advised amount into the cell. Confirm 6. Enter Sample amount. Confirm (*) In Run sample start = Shortcut mode, steps, 3 and 4 and are chained automatically:. Rinse and dip electrodes in beaker.. To start drift determination.

Automatic result display (*) Press to save results (*) In Run sample end = Shortcut mode, this window does not appear and the results are displayed. View statistics (*) then (*) In Run sample end = Shortcut mode, this window does not appear. More tests/end of analysis (*) Running new tests/samples in Run Sample start = Shortcut mode: Rinse and dip electrode in beaker then or (*) In Run sample end = Shortcut mode, this window only appears if several sample replicates have been edited for the method. Stop Del Emergency stop Resume analysis. To resume analysis. Calculations are not performed To end an analysis before the maximum titration time or the maximum volume have been reached. Calculations are performed, if result found DT080 Printed by Radiometer Analytical SAS France 008-09B

Use your Sample stack for daily analyses Running SAC sequences Form no. 5 Preparing the sample stack. 3 XYZ + 5. Locate beaker no. and place it on the sample changer turntable/tray. 6. Enter a new sample ID and confirm Repeat steps to 5 for each beaker in the sequence 3. 4. Check the sample test quantity or enter the sample test quantity to place in beaker no. Confirm + 7. Esc then Esc

Run. (*). Enter User ID, if required, Enter drift and confirm (*) In Run sample start = Shortcut mode, step is skipped. Emergency stop Stop Resume analysis. To repeat titration in the same beaker. Stop Next analysis. To start sequence in the next beaker. Stop Del End of analysis. To stop the sequence. To end an analysis before the maximum titration time or the maximum volume have been reached. Calculations are performed, if result found. DT080 Printed by Radiometer Analytical SAS France 008-09B

For burette air bubble removal, run the Flush procedure Maintenance recommendations Form no. 6 Daily Check and maintain electrodes according to manufacturer recommendations. Check that there is no crystallisation at piston level, if so rinse the burette using appropriate solvent to remove crystals. If not sufficient, dismount burette to remove crystals. Check that there is no crystallisation at addition tip end that may block the reagent to pour freely, if so use appropriate solvent to remove crystals. Check the level of reagent in the reagent bottle Empty waste bottle if installed. Remove air bubbles from the burette and tubing by running a Flush procedure from the burette menu. Weekly Reagent glass cylinder piston Reagent Flush the burette with appropriate solvent to ensure complete cleaning of burette and stopcock. Change burette stand Check the piston for leakages. The burette stand must be changed when at least mm of liquid can be seen between the two sealing lips. Refer to diagram. Having mm or less liquid between the two sealing lips does not require to change the burette stand.

Annualy Replace burette stand,, 5, 0, 5, 50 ml and the anti-diffusion tip, part. no.956-309. Frequent use or use with aggressive or concentrated reagents occurring crystallisation risks may severely reduce the burette and anti-diffusion tip lifetime and may consequently require to replace them more frequently. Replace burette stand set of 3 tubing, (stands 5, 0, 5, 50 ml, part number X3T5 and stand ml, part number X3T6). Replace damaged burette accessories: bottle stopper, desiccant tubing. Contact your Radiometer Analytical representative for instrument revision and cleaning. Recommendations of use After installing new burette and/or tubing, before use, check that all tubing fittings are sufficiently tightened to prevent leakage, and that no tubings are crimped (do not over tight fittings) The reagent should be at room temperature before use in the burette. If you do not use your titration system during several days, always rinse the burette with a suitable solvent (example: ethanol for a KF titrant burette). This makes it possible to lengthen the lifetime of the stopcock and the burette. Organic solvents: the organic solvents given as reacting with and/or destroying the VITON (Fluorinated polymer) should not be used with our burette stands (example: TetraHydroFurane). The solvents given as simply making inflate the VITON are allowed. Please contact us if you wish to work with solvents destroying the VITON. DT080 Printed by Radiometer Analytical SAS France 008-09B

Keep your system in tiptop condition! Storage recommendations Form no. 7 Daily Rinse electrodes and delivery tip throughly with distilled water after use. Store the electrode(s) following the instructions given in the respective operating instructions. Overnight and up to week In case of spillages, clean the exterior surface of the instrument with a soft cloth and tepid water. Avoid the accumulation of excess water around the keyboard area. Long-term week or more Run the Rinse procedure from the Burette menu to remove reagent from burette and tubings. If the system is to be left in the same location, store electrode(s) following the long-term storage instructions given in the respective operating instructions. If the system is to be transported, dismount the burette stand, metal rod, and cell accessories before packing. For transportation, always use the packaging supplied by the manufacturer. DT080 Printed by Radiometer Analytical SAS France 008-09B

Ordering information at a glance Spare parts & accessories Form no. 8 Part no. Type Description X5T05 X5T06 X5T07 X5T07 X5T08 Burette stands B50 Burette Stand, ml, UV protected with connection tubing B505 Burette Stand, 5 ml, UV protected with connection tubing B50 Burette Stand, 0 ml, UV protected with connection tubing B55 Burette Stand, 5 ml, UV protected with connection tubing B550 Burette Stand, 50 ml, UV protected with connection tubing Burette maintenance parts 956-309 Anti-diffusion tip PTFE X3T5 Maintenance Kit of 3 tubes for B5xx & B6xx (excl, ml burette) X3T6 Maintenance Kit of 3 tubes for B50 & B60only X5T00 Delivery tip, glass, burette >5 ml X5T0 Delivery tip, glass, burette <5 ml X3T070 Titrant bottle stopper GL45 assembly with desiccant & suction tubing X3T0 Titrant bottle stopper GL45 assembly with desiccant & suction tubing for B50 Polypropylene titration vessels 904-490 Titration Vessel, PP, 40-00 ml (pack of 50 pcs) 904-489 Titration Vessel, PP, -45 ml (pack of 50 pcs) 904-488 Titration Vessel, PP, 8-5 ml (pack of 50 pcs) 904-487 Titration Vessel, PP, -9 ml (pack of 50 pcs)

Part no. Type Description Notebook keyboard X3T08 X6T005 X6T006 Notebook Keyboard Mask Notebook Keyboard 83-keys, PS/ port, US version Notebook Keyboard 83-keys, PS/ port, French Balance connecting cables A95Z0 C0Z 9pf/m/5pm (Mettler PE+option 06; Mettler AE+option 0 or 0) A95Z05 C05Z 9pf/m/5pm (Mettler PE+option 06; Mettler AE+option 0 or 0) A95Z06 C06Z m serial cable for Mettler AM, PM, SM, AT, MT, UMT, PJ, AJ A95Z0 C0Z 9bf/m/5bm (Sartorius MasterPro, QC, MP8-4) A95Z04 C04Z 9bf/m/5bm (Sartorius MasterPro, QC, MP8-4) A95Z07 C07Z 9pf/.0m/5pm (Precisa, old models) A95Z08 C08Z 9pf/m/RJ45 (Precisa, XB series) For other balances, please consult. KF consumables X3T048 KF Pump Tubing assembly, cell - bottle solvent X3T06 KF Pump Tubing assembly, cell - bottle waste X3T Desiccant Tube with tubing, Bottle - KF pump for bottle stopper GL45 & S40 X3T05 Syringe, plastic, 5 ml (0 pcs) X4T006 Needle, 0 mm, KF cell (0 pcs) X3T038 Silicone Septa for X3T036, set of 0 X3T65 Sample Container with funnel, 5pcs S7T004 Molecular Sieve, 50 g DT080 Printed by Radiometer Analytical SAS France 008-09B

Ordering information at a glance Electrodes and solutions Form no. 9 Part no. Type Description Pt-Pt Metal electrodes Karl Fischer titrations E3M00 M3Pt Double platinum wire, banana plugs *** E3M00 M4Pt-8 Double platinum staples, short cable *** For use with adapter, type BNC-f/ Banana, part no. A94P80 Single Metal electrodes E34M003 M95Ag Silver Rod, ø = 7.5 mm, PTFE body, banana plug ** E3M00 M4Pt Platinum Plate, ø = 7.5 mm, glass body, banana plug ** ** For use with adapter, type BNC-m/Banana-f, part no. A94P807 Temperature Sensor E5M00 T0 Temperature Sensor, glass Electrode Maintenance Solutions S6M00 RENOVO N Normal Cleaning Solution, 50 ml S6M00 RENOVO X Xtra Strong Cleaning Solution, 50 ml DT080 Printed by Radiometer Analytical SAS France 008-09B