Dual readout with tiles for calorimetry.

Similar documents
Dual-Readout Calorimetry with a Mo-Doped PbWO4 Electromagnetic Section

New Results from the DREAM project

G. Gaudio, M. Livan The Art of Calorimetry Lecture V. The state of art Towards ILC calorimetry

On the limits of the hadronic energy resolution of calorimeters. CALOR 2018, Eugene, May

Thin Calorimetry for Cosmic-Ray Studies Outside the Earth s Atmosphere. 1 Introduction

Measurement of the neutron fraction event-byevent

Fig. 11. Signal distributions for 20 GeV * particles. Shown are the measured Éerenkov (a) and scintillation (b) signal distributions as well as the

Time Structure in Dual Readout Calorimeters. Michele Cascella (UCL) for the RD52 Collaboration 1

CALICE scintillator HCAL

Assessment of the Čerenkov light produced in a PbWO 4 crystal by means of the study of the time structure of the signal

Upgrade of the CMS Forward Calorimetry

Dual-Readout Calorimetry Simulations

OPTIMIZATION OF CRYSTALS FOR APPLICATIONS IN DUAL-READOUT CALORIMETRY. Gabriella Gaudio INFN Pavia on behalf of the Dream Collaboration

Studies of Hadron Calorimeter

Digital Imaging Calorimetry for Precision Electromagnetic and Hadronic Interaction Measurements

Equalisation of the PMT response to charge particles for the Lucid detector of the ATLAS experiment

Nuclear Instruments and Methods in Physics Research A

Adam Para, Fermilab CALOR2010, IHEP, Beijing May 14, 2010 TOTAL ABSORPTION HOMOGENEOUS CALORIMETER WITH DUAL READOUT

Dual-readout calorimetry with lead tungstate crystals

STATUS OF ATLAS TILE CALORIMETER AND STUDY OF MUON INTERACTIONS. 1 Brief Description of the ATLAS Tile Calorimeter

Commissioning and Calibration of the Zero Degree Calorimeters for the ALICE experiment

CALICE Test Beam Data and Hadronic Shower Models

ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A

Dario Barberis Evaluation of GEANT4 Electromagnetic and Hadronic Physics in ATLAS

Granularity of ATLAS Tile Calorimeter studied through simulations

Dario Barberis Evaluation of GEANT4 electromagnetic physics in ATLAS

Nuclear Instruments and Methods in Physics Research A

Interaction of particles in matter

Last Lecture 1) Silicon tracking detectors 2) Reconstructing track momenta

ATLAS Hadronic Calorimeters 101

First Stage Analysis of the Energy Response and Resolution of the Scintillator ECAL in the Beam Test at FNAL, 2008

ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A

ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A

PERFORMANCE OF THE ATLAS LIQUID ARGON FORWARD CALORIMETER IN BEAM TESTS

Electromagnetic and hadronic showers development. G. Gaudio, M. Livan The Art of Calorimetry Lecture II

Calorimetry I Electromagnetic Calorimeters

Calorimetry in. in Nuclear and Particle Physics Experiments

This article appeared in a journal published by Elsevier. The attached copy is furnished to the author for internal non-commercial research and

arxiv:hep-ex/ v1 7 Oct 1999

AIRFLY: Measurement of the Air Fluorescence induced by electrons

2nd-Meeting. Ionization energy loss. Multiple Coulomb scattering (plural and single scattering, too) Tracking chambers

Calorimeter test-beam results with APDs

Test setup, APDs,, preamps Calibration procedure Gain monitoring with LED Beam test results Future R&D options

The ATLAS Liquid Argon Calorimeter: Construction, Integration, Commissioning Ph. Schwemling on behalf of the ATLAS LAr Group

Nuclear Instruments and Methods in Physics Research A

Development of a High Precision Axial 3-D PET for Brain Imaging

Hadronic Calorimetry

Hadronic Calorimetry

A gas-filled calorimeter for high intensity beam environments

Calorimetry From basic principles to particle flow an overview. Burkhard Schmidt, CERN PH-DT

Reconstruction in Collider Experiments (Part IV)

Calorimetry in particle physics experiments

First Stage Analysis of the Energy response and resolution of the Scintillator ECAL in the Beam Test at FNAL, 2008

9/27 JUNE 2003 SUMMER STAGE PARTICLES REVELATION THROUGH CERENKOV AND SCINTILLATION COUNTER AND THE CEBAF EXPERIMENT

arxiv: v1 [physics.ins-det] 15 Dec 2017

7 Particle Identification. Detectors for Particle Physics Manfred Krammer Institute of High Energy Physics, Vienna, Austria

HIGH RESOLUTION HADRON CALORIMETRY

arxiv: v1 [physics.ins-det] 23 Oct 2017

Tests of the BURLE 64-anode MCP PMT as the detector of Cherenkov photons

ATLAS Tile Calorimeter performance for single particles in beam tests

Simulation and validation of the ATLAS Tile Calorimeter response

CALICE Si-W EM Calorimeter: Preliminary Results of the Testbeams 2006

Calorimetry at LHC Davide Pinci INFN Sezione di Roma. Calorimetry at LHC 4th Summer School on THE PHYSICS OF LHC

5 Hadronic calorimetry

REVIEW OF CRYSTAL CALORIMETERS

PHY492: Nuclear & Particle Physics. Lecture 25. Particle Detectors

THE CERN NA62 experiment [1] aims to measure the

Scintillation Detectors

Tracker material study with the energy flow through the CMS electromagnetic calorimeter. Riccardo Paramatti, Ambra Provenza

Muon detection with a dual-readout calorimeter

PoS(DIS 2010)058. ATLAS Forward Detectors. Andrew Brandt University of Texas, Arlington

LHCb Calorimetry Impact

Comparison of high-energy hadronic shower profiles measured with scintillation and Cherenkov light

RICH detectors for LHCb

Nuclear Instruments and Methods in Physics Research A

AIM AIM. Study of Rare Interactions. Discovery of New High Mass Particles. Energy 500GeV High precision Lots of events (high luminosity) Requirements

Scintillators for photon detection at at medium energies

Calibration of the BABAR CsI (Tl) calorimeter

Particle Identification: Computer reconstruction of a UA1 event with an identified electron as a candidate for a W >eν event

Temperature Dependence Calibration and Correction of the DAMPE BGO Electromagnetic Calorimeter

Case study: The Lead Tungstate Calorimeter for CMS

Lecture 16 Light transmission and optical detectors

BSO Crystals for the HHCAL Detector Concept

SIDIS Gas CherenkovS. S. Malace, H. Gao et al.

Calibration and Performance of the ATLAS Tile Calorimeter During the LHC Run 2

Pulse height non-linearity in LaBr 3 :Ce crystal for gamma ray spectrometry and imaging

Particle Energy Loss in Matter

The Compact Muon Solenoid Experiment. Conference Report. Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

Lecture 2 & 3. Particles going through matter. Collider Detectors. PDG chapter 27 Kleinknecht chapters: PDG chapter 28 Kleinknecht chapters:

Future prospects for the measurement of direct photons at the LHC

Comparison of high-energy electromagnetic shower profiles measured with scintillation and Cherenkov light

Precision Crystal Calorimeters in High Energy Physics: Past, Present and Future

PoS(TIPP2014)093. Performance study of the TOP counter with the 2 GeV/c positron beam at LEPS. K. Matsuoka, For the Belle II PID group

Experimental Particle Physics

Measurement of the contribution of neutrons to hadron calorimeter signals

ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A

Contributions of Cherenkov light to the signals from lead tungstate crystals

The art of calorimetry part III

Electromagnetic calorimetry for the ILC

Il Calorimetro Elettromagnetico di CMS

Transcription:

Dual readout with tiles for calorimetry. F.Lacava on behalf of the RD52 / DREAM Collaboration Cagliari Cosenza Iowa State Pavia Pisa Roma 1 Texas Tech. 13th Topical Seminar on Innovative Particle and Radiation Detectors (IPRD13) 7-10 October 2013 Siena, Italy 1

Contents - Dual readout in calorimetry. - The DREAM calorimeter. - Dual readout with crystals. - Dual readout with tiles. - Analysis of the muon signals and pm calibration. - Analysis of the electron signals. - Conclusions. 2

The dual readout method. In the calorimeters the energy resolution for hadrons and jets is limited by the large fluctuations of the e.m. energy fraction fem in the shower. In non-compensating calorimeters (where e/h 1) it is possible to eliminate the effects of these fluctuations by measuring event by event the fem. This was done in 2003 in the DREAM calorimeter with two active media: - scintillating fibers for the signal S from the de/dx of all the charged particles. - quartz or plastic fibers for the signal Q of Cherenkov light mostly from the e.m. component of the shower. 3

In DREAM fem was measured from the ratio of the signals Q and S: where 0.21 and 0.77 are the ratios h/e for the Q and S signals. From the measured fem the energy of the shower was corrected. In DREAM the resolution was limited by the small Cherenkov photon yield (8-18 ph.e. per deposited GeV ). Jets 200 GeV (pions interacting in a target). Energy resolution (%). 4

Dual readout in crystals. In the last years extensive studies were performed to extend the dual readout method to homogeneous calorimeters with crystals. In the crystals a fraction of the light yield is given by Cherenkov emission (1% in BGO, up to 15% in PWO). The peculiar features of the Cherenkov light were exploited to separate the two types of light: directionality, timing, spectral properties and polarization of the light. Cherenkov yield was up to 60 ph.e./gev in PBO doped with molybdenum. Two e.m. calorimeters (BGO and PBO crystals) were also tested. A new large fiber dual readout calorimeter tested in 2012 by the RD52 Collaboration. It is composed of 11 modules. Each module is 2.5 m long (10 λint) and 9.2 x 9.2 cm² lateral dimensions, with scintillating and clear fibers for the readout and lead or copper used as absorber. Two papers have been accepted for publication on NIM. 5

Dual readout with tiles. The possibility to use the dual readout technique also in a calorimeter with tiles has been studied. We have tested a small detector with 9 x 9 cm² tiles. The detector is divided in two sections. Each section is: 4 x ( 4mm Lead + 4 mm Quartz + 7 mm Scint. tiles). Its total lenght is 6 R.L. and the Molière radius is 3.7 cm. In each section the signals from the quartz tiles and from the scintillator tiles were separately readout by light guides grouped on the photocathodes. S1 S2 Scintillator pms: Photonis XP 2970 4 mm Lead 4 mm Quartz 7 mm Scint. C1 C2 Cherenkov pms: Hamamatsu R8900 pm 6

Test beam. The small detector was tested in the H8 beam at CERN-SPS. It was positioned on a rotating platform upstream of the DREAM calorimeter. Data were taken with the detector oriented for normal impinging beams (θ=0⁰) and tilted at θ=12⁰ with the beam direction. This last orientation slightly improves the collection of Cherenkov photons. The signals were recorded with the 4 channels of a Tektronix digital oscilloscope (0.8 ns / sample). Data were collected at the two angles for: - 180 GeV muons and - 80 GeV electrons. θ S1 S2 DREAM Calorimeter TC beam C2 C1 7

Analysis of the muon signals. Muons were selected in a 180 GeV electron beam with a cut on the energy measured in the DREAM calorimeter. The average Cherenkov signals were 8 mv at θ=0⁰ and 10 mv at θ=12⁰. θ=12⁰ S1 S2 unit 10⁵ x e C1 C2 unit 10⁵x e Charge distributions for the scintillator signals (S1 and S2) with a 48 ns gate and for Cherenkov signals (C1 and C2) with a 32 ns gate. 8

The large fraction of events with no signal in the Cherenkov distributions suggests a small average number of the collected photoelectrons. We have fitted the q charge distributions for C1 and C2 with a Poisson function for the photoelectron statistics convoluted with a Gaussian function to account for the noise fluctuations: where: k is the number of photoelectrons, m the average number of photoelectrons, qe the charge collected for 1 photoelectron from which the gain of the pm, σq the noise at the anode of the pm, q0 a negligible offset in the distribution. The noise term consists of two contributions: a shot noise from the number of photoelectrons, an electronic noise (dark current, background, white noise..). 9

Fit of the muon signals and pm calibration: C1 θ=0⁰ C1 θ=12⁰ 1 ph.e. 2 ph.e. 3 ph.e. 1 ph.e. 2 ph.e. 3 ph.e. Average signals: < Nph.e. > θ=0⁰ θ=12⁰ pm C1 1.30 1.63 pm C2 1.38 1.68 Gain of the pm tubes: pm C1 = 4.5 10⁶ pm C2 = 3.9 10⁶ 10

Analysis of 80 GeV electrons. The electrons were selected with a cut on the correlations in the Cherenkov signals measured in the two sections of the detector. The HV was too high in S2 and caused a saturation for large signals. In the rest of the analysis we consider only the Cherenkov signals. θ=12⁰ μ π e S1 S2 Saturation from a too high voltage in the S2 pm. C1 C2 11

Cherenkov light yield for electrons. - From the charge spectra we measure the average charge in C1 ad C2. - We had measured the pm gains in the analysis of muon signals. We find the average number of Cerenkov photoelectrons: θ=0⁰ θ=12⁰ pm C1 101 109 pm C2 540 612 - From a GEANT simulation the deposited energies for θ=0⁰ and θ=12⁰ are: - Then the Cherenkov light yield is: 1.42 / 1.55 GeV in Section 1 11.35 / 12.15 GeV in Section 2 70 ph.e. / GeV in Section 1 50 ph.e. / GeV in Section 2 - The fraction (energy only in the quartz tiles) / (energy in the Section) from GEANT is 0.18 in Section 1 and 0.14 in Section 2. The ratio 1.3 of these numbers justifies the ratio 1.4 in the measured light yields in C1 and C2. 12

Conclusions (1) We have studied a small (only 6 R.L.) detector with lead, quartz and scintillator tiles. The measured Cherenkov light yield 50 ph.e./gev is very interesting and comparable with that already measured in other dual readout detectors (crystals, new fiber calorimeters). With this light yield in a full containement e.m. calorimeter with the same sampling the contributions to the resolution from: - the sampling fluctuations : - and the fluctuations from Cherenkov light yield: are comparable. 13

Conclusions (2) A test of a similar tile detector with full longitudinal and lateral containment of the shower should be interesting. In a new prototype the quartz tiles could be replaced by UV transparent plastic tiles with similar refractive index, or by wave shifter tiles. This solution would avoid reflections inside the tiles due to the directionality of the Cherenkov light and could improve the collection of the Cherenkov signal. Of course one should consider to use tiles also for dual readout in hadronic calorimeters. 14

A GEANT simulation of the detector for 80 GeV electrons was performed to calculate the energy deposited in the two sections. Lead Quartz Scintillator 15