Certificate of Analysis

Similar documents
Certificate of Analysis

Certificate of Analysis

Certificate of Analysis

Certificate of Analysis

Certificate of Analysis

Certificate of Analysis

Certificate of Analysis

Certificate of Analysis

Certificate of Analysis

Certificate of Analysis

Certificate of Analysis

(RS)-2-(4-isobutyrylphenyl)propanoic acid Ibuprofen Impurity J

Annex to the Accreditation Certificate D-RM according to ISO Guide 34:2009 and DIN EN ISO/IEC 17025:2005

Period of validity: to date of issue:

Certified Reference Material - Certificate of Analysis Methylone, Primary Standard

Certified Reference Material - Certificate of Analysis

Certificate of Analysis

Certified Reference Material - Certificate of Analysis

Certificate of Analysis

ASPIRIN (ACETYLSALICYLIC ACID) CERTIFIED REFERENCE MATERIAL

Certificate of Analysis

PHENYLEPHRINE HYDROCHLORIDE CERTIFIED REFERENCE MATERIAL

Certificate of analysis Certified reference material code: CRM-00-GTX1&4

Certificate of Analysis

Quality? Who Decides? Mitzi M. Rettinger Vice President, Sales & Marketing Cerilliant Corporation Round Rock, TX

Final Report. Characterisation of Sample Report. Job No 2016/11/12-34 AS No. 1234A. Client Example Contact Sample. Signed Date 2017.

A61-02 CALA Guidance on Traceability Revision 1.2 October 15, 2012

The Uncertainty of Reference Standards

Certificate of analysis Certified reference material code: CRM-00-NEO

ANALYSIS CERTIFICATE OF

Tri-n-propyltin Chloride Mixture

Metolachlor ESA Sodium Salt Standard

7. Stability indicating analytical method development and validation of Ramipril and Amlodipine in capsule dosage form by HPLC.

Multi Analyte Custom Grade Solution. Aluminum, Potassium, Magnesium, ANALYTE CERTIFIED VALUE ANALYTE CERTIFIED VALUE

HPLC Reverse Phase Test Mix #1

BRIEFING. (EXC: K. Moore.) RTS C Propylparaben C 10 H 12 O Benzoic acid, 4 hydroxy, propyl ester; Propyl p hydroxybenzoate [ ].

Technical Procedure for Concentration Determination of Methamphetamine in Liquids via HPLC

Flk = Acy + Cy z. Discover the perfect formula Fluka Reagents. Fluka TM Accuracy Consistency AUTHENTIC

การใช REFERENCE STANDARDS ในการควบค มค ณภาพยา

USP Method Transfer and Routine Use Analysis of Irbesartan Tablets from HPLC to UPLC

Delta-9-THC Standard. Catalog # Lot # A082745

USP Class 1 Residual Solvent Mixture

International Atomic Energy Agency. Department of Nuclear Sciences and Applications. IAEA Environment Laboratories

TEMPLATE FOR AN EXAMPLE STANDARD TEST METHOD

VOC TEST REPORT CDPH

MEDROXYPROGESTERONE INJECTION

Appendix II- Bioanalytical Method Development and Validation

BUFOTENINE Latest Revision: August 16, 2005

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION

High Performance Liquid Chromatography. Table 1: Allowed HPLC Adjustment of USP <621> and EP <2.2.46>

Additionally, minor editorial changes have been made to update the monograph to current USP style.

Multi Analyte Custom Grade Solution. Calcium, Iron, Potassium,

IDENTIFICATION OF STEROIDS IN COSMETIC PRODUCTS BY TLC AND HPLC 1 02/12/2005 ACM 007 A. THIN LAYER CHROMATOGRAPHY (TLC)

H 3 CO H 3 CO S CH 3

ADVANTAME. Not less than 97.0% and not more than 102.0% on the anhydrous basis. Sweetener, flavour enhancer

1-(2-METHOXYPHENYL)PIPERAZINE Latest revision: June 27, 2005

2,5-DIMETHOXY-4-IODOPHENETHYLAMINE Latest Revision: August 22, 2005

Technical Procedure for Blood Cannabinoid Liquid-Liquid Extraction (BCLLE) for Analysis by LC-MS/MS

Test Report. Tremco-Illbruck GmbH & Co KG. Product Emissions Test (AgBB/DIBt Test Protocol) Butyl und Bitumenprimer. June 2011

Selective Formation of Benzo[c]cinnoline by Photocatalytic Reduction of 2,2 Dinitrobiphenyl with TiO 2 and UV light irradiation

Test Report in accordance CDPH-IAQ

Traceability, validation and measurement uncertainty 3 pillars for quality of measurement results. David MILDE

Streamlining the Analysis of Oral Contraceptives Using the ACQUITY UPLC H-Class System

ADVANTAME (TENTATIVE)

VOC TEST REPORT M1. 6 April Regulation or protocol Conclusion Version of regulation or protocol

Test Report. Muovihaka Oy. Product Emissions in accordance with the Swedish Building Material Assessment Ultima graphite.

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

VOC EMISSION TEST REPORT ISO 16000

VOC TEST REPORT CDPH

637. Thiamethoxam. HPLC method

2017 Reaction of cinnamic acid chloride with ammonia to cinnamic acid amide

Basic Principles for Purification Using Supercritical Fluid Chromatography

The Uncertainty of Reference Standards A Guide to Understanding Factors Impacting Uncertainty, Uncertainty Calculations, and Vendor Certifications

VOC EMISSION TEST REPORT BREEAM NOR

Chapter 4: Verification of compendial methods

ETD Verification Kit

Test Report. Glava AS. Emission test of Ecophon Venus according to M1 classification. October / November Smedeskovvej 38, DK-8464 Galten

Ondansetron Hydrochloride Tablets

Technical Note A Quantification and NIST Traceability of Micromatter Thin Film Standards for XRF Analysis. Version March 16, 2017

Certified BTEX in Unleaded Gas Composite

Routine MS Detection for USP Chromatographic Methods

Simultaneous, Fast Analysis of Melamine and Analogues in Pharmaceutical Components Using Q Exactive - Benchtop Orbitrap LC-MS/MS

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity

VOC TEST REPORT CDPH

Analysis of Illegal Dyes in Food Matrices using Automated Online Sample Preparation with LC/MS

Single Analyte Custom Grade Solution. CGWH2O1 M2-W H2O µg/ml ea: Tungsten Ammonium Metatungstate

Sulfotepp impurities in Chlorpyrifos EC formulations

Prep 150 LC System: Considerations for Analytical to Preparative Scaling

VOC TEST REPORT M1. 23 October Regulation or protocol Conclusion Version of regulation or protocol

GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY

Perfluorinated Alkyl Acids (PFAA) in Water by LC/MS/MS - PBM

1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

serve the goal of analytical lmethod Its data reveals the quality, reliability and consistency of

EMICODE Test Report. 1 Sample Information. 2 Evaluation of the Results. Report No. G12871B_02

VOC TEST REPORT EMICODE

Aldehydes/Ketones DNPH Standard

VOC TEST REPORT M1. 16 August Regulation or protocol Conclusion Version of regulation or protocol

CIPAC. CIPAC Free relevant impurities methods:

Achieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer

TECHNICAL BRODIFACOUM

Transcription:

Certificate of Analysis Reference Material - Primary Standard Product Name: Metoprolol Tartrate 1.0 mg/ml in Methanol (as free base) Catalogue Number: LGCAMP0027.00-01 Lot Number: 8525 CAS Number: 56392-17-7 O OH H N Molecular Formula: (C 15 H 25 NO 3 ) 2 C 4 H 6 O 6 Molecular Weight: 684.81 Solvent: Methanol Volume per Ampoule: Not less than 1 ml 1 O x HO O OH OH O OH 2 Long-term Storage: 2 to 8 C, dark Expiry Date: Intended Use: October-2020 The primary aim of this material is for identification, calibration and quantification. Component Concentration ( free base ) Uncertainty see product name 1.000 mg/ml 2 U = 0.006 mg/ml 3 Uncertainty of the concentration is expressed as an expanded uncertainty in accordance with ISO 17025 and Guide 34 at the about 95 % level of confidence using a coverage factor of k = 2 and has been calculated by statistical analysis of our production system and incorporates uncertainty of the purity, material density and balance and weighing technique. Concentration based on material weighings and material purity factor (assay of the neat material). The solution s concentration and homogeneity are verified by independent method. LGC certifies that this standard meets the specification stated in this certificate and warrants this product to meet the stated acceptance criteria through the retest date when stored unopened as recommended. Product should be used shortly after opening to avoid concentration changes due to evaporation. Warranty does not apply to ampoules stored after opening. Release Date: Luckenwalde, April 2012 Signed: Dr. Sabine Schröder Unit for Reference Materials 1 Ampoules are overfilled to ensure a minimum 1 ml volume fill. We advise laboratories to use measured volumes of this standard solution before diluting to the desired concentration. 2 The value is based on the results of analytical techniques, which calibration and verification was carried out with standards traceable to SI-units. The value is expressed on a "free base" basis. The concentration with its uncertainty is valid in the range between 19 C and 25 C. The identity is verified by data from international scientific literature. Gravimetrically prepared using qualified balances calibrated annually by accredited calibration service. Calibration verification performed daily prior to use utilizing weights traceable to SI via other mass standards. 3 The uncertainty U is the expanded uncertainty estimated in accordance with the Guide to the Expression of Uncertainty in Measurement (GUM). It is corresponding to a level of confidence of about 95 %. Standard uncertainties are indicated with u. LGC GmbH, Im Biotechnologiepark, TGZ II, D-14943 Luckenwalde, Germany 2012 LGC limited. All rights reserved. LGC Standards is part of the LGC Group. LoGiCal is a registered trademark of LGC Standards GmbH 8 pages

Additional information Concentration ( as is ) 1.281 mg/ml Verification of Concentration and Homogeneity Lot Number Verified Concentration (mg/ml) Result Acceptance Criteria % RSD - Homogeneity Result Acceptance Criteria 8525 1.006 ± 3 % 0.856 3 % Concentration verified by HPLC Solution Standard Assay Parameters Analysis Method HPLC External Calibration (100 % amount) Column: 60 RP Select B, 5 µm, 125 x 4 mm Number of Measurements: 6 Injector: Auto; 3 µl; 1.0001 mg/ml in Methanol Flow: 1.0 ml/min, 40 C Detector: 220 nm Conditions: mob. Phase A: Water + 0.1 % H 3 PO 4, mob. Phase B: Acetonitrile + 0.1 % H 3 PO 4 0-6 min A/B 80/20, 6-9 min A/B to 30/70, 9-11 min A/B to 80/20, 11-18 min A/B 80/20 (v/v) Neat Material Data Product Name: Metoprolol Tartrate CAS Number: 56392-17-7 Molecular Formula: (C 15 H 25 NO 3 ) 2 C 4 H 6 O 6 Molecular Weight: 684.81 Compound Lot: 7092 Test Method Result Melting Point ( C)* SOP 06-010 122 C 1 H-NMR Spectrum* SOP 06-053 conform / complies to structure IR Spectrum* SOP 06-036 conform / complies to structure Mass Spectrum (ESI)* SOP 06-022 conform / complies to structure Assay by carbon titration (free base)* Elementary Analysis 78.05 % The expanded uncertainty according to the assay is U = 0.46 % (about 95 % level of confidence using a coverage factor of k = 2). Assay by carbon titration ( as is )* 99.96 % *: Validated method performed by ISO/IEC 17025 accredited testing lab The assay of the neat material is verified by the 100 % method using HPLC, corrected with water (KFT) and residual solvents. LGC GmbH, Im Biotechnologiepark, TGZ II, D-14943 Luckenwalde, Germany page 2/8

I. Identity The identity of the reference substance (neat material) was established by the following analyses. Ia. 1 H-NMR Spectrum Conditions: 400 MHz, DMSO-d 6 The structure is confirmed with the signals of the spectrum and their interpretation. LGC GmbH, Im Biotechnologiepark, TGZ II, D-14943 Luckenwalde, Germany page 3/8

Ib. Mass Spectrum Method: 4.5 kv ESI; vaporization temperature: 200 C, direct inlet m/z fragments (M = free base) 268.05 [ MH ] 249.96 [ MH H 2 O ] 218.05 [ M H 2 O CH 3 O ] 190.99 [ MH H 2 O C 3 H 7 O ] 116.03 [ C 6 H 14 NO ] The signals of the mass spectrum and their interpretation are consistent with the structural formula. LGC GmbH, Im Biotechnologiepark, TGZ II, D-14943 Luckenwalde, Germany page 4/8

Ic. IR Spectrum Method: attenuated total reflection fourier transform infrared (ATR-FTIR) spectroscopy The signals of the IR spectrum and their interpretation are consistent with the structural formula. Id. Melting Point 122 C Ie. UV Spectrum Method: HPLC (DAD-detection) LGC GmbH, Im Biotechnologiepark, TGZ II, D-14943 Luckenwalde, Germany page 5/8

II. Assay by Elementary Analysis (Carbon Titration neat material) Method: percentage carbon found in relation to percentage carbon as calculated for molecular formula Results: Arithmetic mean (n=3) 99.96 % (mass fraction) Uncertainty U 0.59 % III. Purity IIIa. High Performance Liquid Chromatography (HPLC) The purity of the reference substance (neat material) was analysed by high performance liquid chromatography (HPLC). 300 Surveyor_5 PDA-220nm Retention Time 300 250 250 200 200 mau 150 150 mau 100 100 50 50 1,85 2,30 3,80 0 2,72 0 0 2 4 6 8 10 12 14 16 18 20 Minutes Area Percent Report - Sorted by Signal Pk # Retention Time Area Area % 0.97 Tartrate Peak 1 1.85 589 0.03 2 2.30 1667 0.07 3 2.72 2282652 99.89 4 3.80 245 0.01 Totals 2285153 100.00 LGC GmbH, Im Biotechnologiepark, TGZ II, D-14943 Luckenwalde, Germany page 6/8

For the calculation the tartrate peak and the system peaks were ignored. The content of the analyte was determined as ratio of the peak area of the analyte and the cumulative areas of the purities, added up to 100 %. HPLC Conditions: Column: Conditions: Detector: Injector: RP 60 Select B 1.0 ml/min, 40 C DAD Auto 5 µm, 125 x 4 mm Water/Acetonitrile 75/25 (v/v); 0.1 % H 3PO 4 220 nm 5 µl; 0.0636 mg/ml in Water/Acetonitrile 50/50 (v/v) Results: Arithmetic mean (n=6) 99.89 % IIIb. Water Content Method: coulometric Karl Fischer titration Results: Arithmetic mean (n=3) 0.08 % (mass fraction) IIIc. Residual Solvents Method: 1 H-NMR No significant amounts of residual solvents were detected (< 0.05 %). IV. Stability and Homogeneity Accelerated stability studies indicate no significant instability. The given validity period is based on this data. This is backed up by historical data over the range of several years for the neat substance. Homogeneity assured by validated process of preparation (incl. ampoulation), verified by homogeneity testing (HPLC). LGC GmbH, Im Biotechnologiepark, TGZ II, D-14943 Luckenwalde, Germany page 7/8

V. Further Information General For laboratory use only. Not suitable for human or animal consumption. This material conforms to the characteristics of a primary standard as described within ISO Guide 30 (Terms and definitions used in connection with reference materials). The certified values quoted in this certificate are LGC s best estimate of the true values within the stated uncertainties and based on the techniques described in this certificate. Handling of the RM Before usage of the RM, it should be allowed to warm to room temperature. The concentration with its uncertainty is guaranteed in the range between 19 C and 25 C. The uncertainty accounts for the temperature-dependent density in this range. Quality Control Assessment The product quality is controlled by regularly performed quality control tests (retests). Revision Date Reason for Revision 00 April 2012 Release of the Lot initial version 01 October 2012 Copyright added 02 November 2014 Expiry Date adaption from February 2013 added 03 November 2015 Expiry Date adapted 04 November 2016 Expiry Date adapted LGC GmbH, Im Biotechnologiepark, TGZ II, D-14943 Luckenwalde, Germany page 8/8