DIGITAL THERMOMETER WITH TRICOLOR LCD INSTRUCTION MANUAL

Similar documents
Infrared / K Thermometer Remote Temperature Measurement ( Non-Contact ) 1327K INSTRUCTION MANUAL

IR F ( C) ENGLISH INSTRUCTION MANUAL. Thermometer

HL-800K Infrared Laser Thermometer. -50 C to +800 C (13:1 ratio) User Manual

Stick-Style Water-Resistant Infrared Thermometer for Foodservice Applications with 4:1 Distance-to-Sight Ratio Model

User Manual. Stick-Style Water-Resistant Infrared Thermometer with 8:1 Distance-to-Sight Ratio. Model with NIST-Traceable Calibration

INFRARED THERMOMETER TM0819

566/568. Infrared Thermometers. Getting Started

Model ST-616CT. Instruction Manual. Infrared Thermo-Hygrometer. reedinstruments. www. com

Instruction Manual SEFRAM Thermal Camera

INFRARED THERMOMETER Model : TM-959

GS-IR 8816 Series Infrared Thermometer

INSTRUCTION MANUAL DTH Fax: (503)

InfraRed Thermometer with Laser Pointer

Introduction Cautions

WE RE HERE TO HELP: 1 (844) LIGHTCLOUD

Model: WT-3181PL Instruction Manual DC: Indoor/Outdoor Atomic Wall Clock. Get Started

Today s Weather 24 Hour Forecaster

INSTRUCTION MANUAL Fax: (503)

Infrared Thermometer Model: and

6 + WARNING: CHOKING HAZARD - Small parts/small ball(s). Not for children under 3 years.

INSTRUCTION MANUAL INF Fax: (503)

63/66/68. Infrared Thermometers. Users Manual

Non - Contact Forehead Infrared Thermometer. Care Q7 USER MANUAL - 1 -

IR 80-H. Non-Contact Infrared Temperature Sensor/Transmitter. Temperature Range: 500~1700

IR/Thermistor Pen. Instruction Manual

INSTRUCTION MANUAL. Laser Diode Sarcomere Length. Aurora Scientific Inc. 360 Industrial Parkway South, Unit 4 Aurora, Ontario, Canada L4G 3V7

WT-3131A Radio-controlled Analog Clock With Weather Forecast. Instruction Manual

Gun-Type Professional Infrared Thermometer MODEL: ST 653. Instruction Manual

DHS1900 DHS3000 High Temperature Hand Held Infrareds User Manual

IMPORTANT. Questions? Contact Customer Support at (877) or visit Display for 5-in-1 Weather Sensor model 06016RM

WS-7047TWC Wireless 433 MHz Weather Station With Rainfall and Temperature. Instruction Manual

IR-712 IR-712-EUR 12:1 Infrared Thermometer. IR-720 IR-720-EUR 20:1 Infrared Thermometer. IR-730 IR-730-EUR 30:1 Infrared Thermometer.

CAUTION: BEFORE YOU BEGIN, ALWAYS MAKE SURE THE WEAPON IS UNLOADED AND SAFE TO HANDLE.

WS-7213U Wireless 433 MHz Weather Station Instruction Manual TABLE OF CONTENTS. Figure 2. Figure 1

IR 40. Non-Contact Infrared Temperature Sensor/Transmitter. Temperature Range: 0~1000

WS-7211U Wireless 433 MHz Weather Station. Instruction Manual

CONTENTS. Batteries. La Crosse Technology, Ltd Page 1

SKELESCOPE REFLECTOR TELESCOPE WITH TABLE TOP TRIPOD SK-100 INSTRUCTION MANUAL

Dual laser + type K thermometer INFRARED THERMOMETER

ABB temperature measurement Radiation thermometry. Measurement made easy. Process temperature measurement practice--non-contacting

WS-7038U Wireless 433 MHz Miniature Rain Monitor. Instruction Manual

Instruction Manual HI Refractometer for Invert Sugar Measurements

Kingspan Smart-Lite Kite Luminaire

Instruction Manual HI Refractometer for Sodium Chloride Measurements

FIELD GUIDE FOR HORUS SCOPES

Infrared Thermosensor ES1C

DIAGNOSTICS NO TOUCH FOREHEAD THERMOMETER

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000

Ground Penetrating Radar & By Mike Kelty Western Technologies Inc.

One-Year Limited Warranty

SK Series BOX PLOW INSTALLATION & OWNER S MANUAL TABLE OF CONTENTS

Avery Dennison LV-0700 Series Retroreflective Validation Decal Film Issued: July 2013

INSTRUCTION MANUAL Milwaukee Refractometer MA881 Refractometer for Invert Sugar Measurements

Hadrons Desktop U.S. Atomic Clock & Weather Station

EM90 INFRA-RED THERMOMETER & THERMOCOUPLE METER

WeatherHub2 Quick Start Guide

HI Refractometer for Sodium Chloride Measurements INSTRUCTION MANUAL

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL. Milwaukee Refractometer

Operating instructions Infrared temperature sensor TW20xx TW21xx

MAGMA NOTE! 21+ USER MANUAL

New! 2010 Model. Model No

Medium Pressure Sensor Analog Output

Fischer Instruments Chrome and Black Wood Base Weather Station with Barometer, Hygrometer, Thermometer and Quartz Clock User Manual

HS515G-M. PARALOW Circle Dot Sight. User's Manual. Holosun Technologies Inc. Phone: (909) Fax: (909)

XR Analog Clock - Manual Setting Model Troubleshooting Guide

6.Ebz!boe!8.Ebz!!! Gpsfdbtufst!!! G U I D E n catio Lo

Device Specifications

Coating Thickness Gauge TW-8. art. nr Thoma Tel./Fax: Operation Manual

Fischer 1508BTH-45 5" Brass Barometer with Temperature & Humidity User Manual

User s Guide. Waterproof Palm ph Meter Model PH220. Introduction

Professional Wind Station

SMD B EASV1003WA1. Applications Telecommunication: indicator and backlighting in telephone and fax. Flat backlight for LCD, switch and symbol.

Wireless Weather Station. Instruction Manual

WHEN BRIGHTNESS COUNTS

MN-ISO-2000FN-E. ISO-2000FN COATING THICKNESS GAGE OPERATION MANUAL

Avery Dennison LW Series Retroreflective Window Sticker Film Issued: July 2013

Low Pressure Sensor Amplified Analog Output SM6295-BCM-S

Instruction Manual HI Refractometer for Sucrose in Wine and Grape Products Measurements

3mm Phototransistor PT204-6C

Owner's Manual NSL100B BUILDERS LEVEL NSL500B TRANSIT LEVEL

WS-9018U Wireless Weather Station. Instruction Manual

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual

IR-712 IR-720 IR-730

SkyScan EWS-PRO - Manual -

High Resolution High Sensitivity SDR Super Wide Dynamic Camera

HI Propylene Glycol Refractometer INSTRUCTION MANUAL

User s Guide. Shown with Built-in Laser Sighting. OS531, OS532, OS533, OS534 OMEGASCOPE Handheld Infrared Thermometer

M2 SERIES THERMOSTATS 0 F to 240 F, Narrow Differential, Hermetically Sealed ½

Ultra-Small Footprint N-Channel FemtoFET MOSFET Test EVM

Wireless Color Forecast Station Model: K86319

IRTS-P PRECISION INFRARED TEMPERATURE SENSOR INSTRUCTION MANUAL

IT Series Infrared thermometer Using manual

SUNLIKE DISPLAY. Model No: SC2004C GENERAL SPECIFICATION

Quick Reference. Daily Cleaning Procedures Pages 3-8 Stopping Conditions & Recovery Steps Pages 9-20

Every object with a temperature above 0 Kelvin= -273,15 C emits

RADIATION-METER TM-91/TM-92

INSTRUCTION MANUAL Milwaukee Refractometer MA888 Refractometer for Ethylene Glycol Measurements

Explanation: The factory restart returns the atomic clock to an out-of-the-box state and often resolves an issue.

MEASURE MASTER PRO. Pocket Reference Guide. Model FEET-INCH-FRACTION and METRIC CALCULATOR

INSTRUCTION MANUAL Milwaukee Refractometer MA886 Refractometer for Sodium Chloride Measurements

Transcription:

Model no 240022 Component No. 692650 DIGITAL THERMOMETER WITH TRICOLOR LCD INSTRUCTION MANUAL THIS MANUAL CONTAINS IMPORTANT INFORMATION REGARDING SAFETY, OPERATION, MAINTENANCE AND STORAGE OF THIS PRODUCT. BEFORE USE, READ CAREFULLY AND UNDERSTAND ALL CAUTIONS, WARNINGS, INSTRUCTIONS AND PRODUCT LABELS. FAILURE TO DO SO COULD RESULT IN SERIOUS PERSONAL INJURY AND/OR PROPERTY DAMAGE. IF YOU SHOULD HAVE ANY QUESTIONS OR EXPERIENCE A PROBLEM WITH YOUR ALLTRADE PRODUCT, DO NOT RETURN THIS PRODUCT TO THE STORE. PLEASE CALL OUR CUSTOMER SERVICE DEPARTMENT AT 1-800-423-3598. BEFORE YOU CALL, HAVE THE FOLLOWING INFORMATION AVAILABLE: MODEL No., DATE PURCHASED AND STORE LOCATION. AN ALLTRADE REPRESENTATIVE CAN RESOLVE YOUR PROBLEM OVER THE PHONE. IF YOU WOULD LIKE TO MAKE A SUGGESTION OR COMMENT, GIVE US A CALL OR EMAIL US AT: INFO@ALLTRADETOOLS.COM. YOUR FEEDBACK IS VITAL TO US.

TABLE OF CONTENTS INTENDED USE.... 1 GENERAL SAFETY RULES.... 1-3 RECOGNIZE SAFETY SYMBOLS, WORDS AND LABELS.... 1 LASER SAFETY.... 2 TOOL USE AND CARE... 2-3 FUNCTIONAL DESCRIPTION.... 3-4 LCD INDICATIONS AND SYMBOLS.... 4 BUTTON FUNCTIONS.... 4 BATTERY INSTALLATION/REPLACEMENT... 4-5 OPERATING INSTRUCTIONS.... 5-8 C / F TEMPERATURE UNIT SETTING.... 6 REFERENCE TEMPERATURE SETTING & MEASUREMENT.... 6 EMISSIVITY ADJUSTMENT... 7-8 CLEANING AND STORAGE.... 9 SPECIFICATIONS.... 9 1 YEAR LIMITED WARRANTY... 10 FCC INFORMATION.... 10 INTENDED USE This product is intended for consumer use only. It is designed to be used for non-contact temperature measurement by measuring the amount of infrared energy radiated from the object s surface. GENERAL SAFETY RULES READ AND UNDERSTAND ALL INSTRUCTIONS. Failure to follow all instructions in this manual may result in severe personal injury or death. Keep this manual and refer to it for Safety Instructions, Operating Procedures and Warranty. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. RECOGNIZE SAFETY SYMBOLS, WORDS AND LABELS WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. This product contains chemicals known to the State of California to cause cancer, birth defects and other reproductive harm. For more information go to www.p65warnings.ca.gov. 1

LASER SAFETY Pointing a laser and interfering with the operation of an aircraft is a felony punishable by fine and imprisonment. The laser guide used in the tool is Class II. The laser shall be used and maintained in accordance with the manufacturer s instructions. The use of optical instruments with this product will increase eye hazard. Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure. Do not stare into the laser beam. Never aim the beam at any person or an object other than the work piece. Avoid indirect exposure via reflective surfaces, such as glass and mirrors. Store out of reach of children. Equipment should be in a high location or locked up to keep out of reach of children. It is not a toy. Do not tamper with the laser output. Changing the performance of the laser to increase its output is prohibited. Any claim for damages or injuries resulting from not following these instructions will be refused. Never operate laser if the unit is defective or the cover or seal is damaged. There are no user-serviceable parts in the laser device. The laser unit must be returned to the factory for any service or repair. Service or repair must be handled by authorized factory trained technicians. Be careful with this tool. Striking or jarring it, especially on the laser housing can affect its accuracy. TOOL USE AND CARE AVOID EXPOSURE Laser Radiation is emitted from this aperture CAUTION DIODE LASER LASER RADIATION 1 MW MAX OUTPUT AT 630-670 NM CLASS II LASER PRODUCT DO NOT STARE INTO BEAM OR VIEW DIRECTLY WITH OPTICAL INSTRUMENTS Serial No: XXXXXXXXX 0601000040 Complies with FDA 21CFR, 1040.10 & 1040.11 Alltrade Tools LLC Made in China IR Thermometer Label Use the product only as specified in this manual. Avoid exposing this device to EMF (electro-magnetic fields) from arc welders, induction heaters, etc. OR exposing to static electricity. To prevent sensor damage, do not point the sensor lens directly at the sun or any other source of strong infrared light. 2

Do not leave the thermometer on or near objects of high temperature exceeding 158 F. Be certain there is no condensation on the lens prior to taking measurements. Allow 10 minutes for condensation to dissipate as needed. Shiny surfaces result in lower than actual temperature measurements. For the most accurate temperature measurements, aim the infrared thermometer perpendicular to the target. The IR thermometer cannot measure through transparent surfaces such as glass and plastic. It will measure the surface temperature instead. Steam, dust, smoke and/or vapours can prevent accurate measurement by obstructing the unit s optics. For better accuracy, keep the sensor perfectly clean. Refer to the spot size information on the instrument (and in the manual) for the target spot size being measured at a given distance. FUNCTIONAL DESCRIPTION Shift Left Button LCD Shift Right Button Laser pointer Infrared (Fresnel) lens & Sensor Trigger Battery housing cover Set Button 2 AA batteries 3

LCD INDICATIONS AND SYMBOLS 1. Low Battery Indication 2. Measurement Icon 3. Current Reading 4. Switch Off REF function 5. Threshold Value Selection 6. Temperature Unit ( C/ F) 7. Reference Temperature 8. REF Icon BUTTON FUNCTIONS SET button: Sets Reference Temperature, C or F unit and Emissivity adjustment mode. Shift Left/Right Buttons: Sets Threshold values {0.5 C (1 F), 3 C (5 F), 5 C(10 F), OFF} and Emissivity (0.1 to 1.0). BATTERY INSTALLATION/REPLACEMENT To maintain reading accuracy, when the low battery icon appears, replace thermometer s battery. 1. Place fingers behind the battery housing cover tabs and gently pull open the cover. 2. Pull the plastic ribbon under the batteries to pull the batteries out. 3. Insert two fresh AA Alkaline batteries (with correct polarity as shown by the marking on the side of battery housing) over the plastic ribbon inside the housing. Close the cover. Always purchase the correct size and grade of battery most suitable for the intended use. Always replace both batteries and install with correct polarity inside thermometer. BATTERY POLARITY MARKING 4 HOUSING COVER PLASTIC RIBBON BATTERY COVER TAB

Clean the battery contacts and also those of the device prior to battery installation. Remove batteries from equipment which is not to be used for an extended period of time. Remove batteries if consumed or if product is to be left unused for a long time. OPERATING INSTRUCTIONS Never aim the laser beam pointer at the eyes of a person or animal or an object other than the work piece. Follow these steps to measure surface temperature of an object in most applications. See next section for additional measurement features. 1. Aim the thermometer at the object and squeeze the trigger for at least 3 seconds, SCAN icon will appear on the display during measurement. Use the laser pointer to aim at the object more accurately. 2. Release the trigger to display the Most Recent temperature reading. The display will Remain and automatically will shut off after Approximately 1 minute. 3. For accurate temperature measurement ALWAYS follow the D:S (11:1) ratio rule. For example, if the diameter of the surface (S) is 1 ft., the distance (D) between the IR thermometer and surface should be LESS than 11 ft. For the most accurate readings, the distance between the thermometer and the target should be 1/2 of D or 1/2 x D:S x target diameter. For our example: Optimum Distance = 1/2 x 11 x 1ft = 5.5ft for the target diameter of 1ft. NOTE: Temperature measurement will not be accurate off shiny objects (such as stainless steel, gold, aluminum wrapping) or through glass or windows. LEAST ACCURATE (TARGET < S) ACCURATE (TARGET = S) MOST ACCURATE (TARGET > S) D (DISTANCE) 1/2 D LASER POINTER S (SPOT) TARGET 5

C / F TEMPERATURE UNIT SETTING 1. Briefly press the trigger to turn on the display. 2. Briefly press the SET button to toggle between C or F. The selected unit is saved in the thermometer memory. REFERENCE TEMPERATURE SETTING & MEASUREMENT Use this feature to compare the surface temperature of an object with a saved reference temperature in thermometer memory. The comparison is visually indicated by 3 backlight colors (Blue, Green, Red) on the LCD display. If the scanned surface temperature is hotter than the reference temperature by more than the threshold value, the LCD color will turn from green to red along with the fast repeating beeper sound to warn users. If the scanned surface temperature is colder than the reference temperature by more than the threshold value, the LCD color will turn from green to blue along with the slow beeper sound to warn users. If the scanned surface temperature is within the threshold value, the LCD color will be in green, If Reference Temperature mode is turned off, the default LCD color is yellow. Reference Temp. Threshold Threshold Blue (Colder) Green (Within) Red (Hotter) Scanned Surface Temperatures and Corresponding Display Colors 1. Aim the thermometer at the surface spot to be used as reference temperature and press the trigger. 2. While pressing the trigger, briefly press the SET button. After appearance of the reference temperature value at the top right corner of the LCD display and a short beep, the reference value is saved in thermometer memory. 3. Set temperature Threshold Value by pressing the shift left button or shift right button to select the suitable threshold value from choices of 0.5 C (1 F), 3 C (5 F), 5 C (10 F) or OFF to turn off the Reference Temperature function. 4. While pressing the trigger, aim and scan various surfaces and observe the change in color of LCD display. 5. To change the reference temperature, aim at a new reference spot, press the SET button to save the new reference temperature. If you allow the thermometer to turn off, the saved threshold value in the memory will be erased. Repeat steps 1-4. 6

EMISSIVITY ADJUSTMENT Emissivity is the measure of an object s ability to emit infrared energy. Emitted energy indicates the temperature of the object. Emissivity can have a value from 0 (shiny mirror) to 1.0 (blackbody). An emissivity of 1.0 implies that the material is 100% efficient at radiating energy. An emissivity of 0.1 implies that the material radiates only 10% of that which it is capable of radiating. To compensate for deficiency of radiated energy and improve the accuracy of temperature readings, use the Emissivity chart below to set the Emissivity of the surface which is to be scanned. To set the desired emissivity: 1. Briefly press the trigger to turn on the display. 2. Press and hold the SET button for around 3 seconds to enter into the emissivity adjustment mode. 3. Select the emissivity value of the scanned material from the chart below. 4. Set the emissivity value by repeatedly pressing button to increase the value, or by repeatedly pressing button to decrease the value of emissivity. 5. After setting the emissivity value, press the SET button for a few seconds to save the value in the thermometer memory and exit the emissivity adjustment mode. Notes: Most organic, painted, or oxidized surfaces have emissivity values close to 0.95. The default emissivity value of the thermometer is set at 0.95 which is suitable for most applications. Since the thermometer retains the emissivity setting in its memory, always check for emissivity to ensure that it is either set to default (0.95) or an emissivity value corresponding to the surface to be scanned (from Emissivity chart). Surface Material Emissivity Surface Material Emissivity Of Some Common Materials Emissivity Surface Material Aluminum Foil 0.04 Gold not polished 0.47 Paint 0.96 Aluminum Sheet 0.09 Gold polished 0.025 Paper 0.93 Aluminum Oxidized 0.2-0.31 Granite 0.45 Plaster, rough 0.91 Emissivity Aluminum Polished 0.039-0.057 Gravel 0.28 Plastics 0.90-0.97 Aluminum Anodized 0.77 Gypsum 0.85 Polypropylene 0.97 Aluminum Rough 0.07 Ice smooth 0.966 Porcelain glazed 0.93 Asbestos board 0.96 Ice rough 0.985 PVC 0.91-0.93 Asbestos paper 0.93-0.945 Iron polished 0.14-0.38 Quartz glass 0.93 Asphalt 0.93 Iron, rusted red 0.61 Roofing paper 0.91 Black Body Matt 1 Iron, dark gray 0.31 Rubber, foam 0.9 7

Surface Material Emissivity Surface Material 8 Emissivity Surface Material Black lacquer on iron 0.875 Iron, rough ingot 0.87-0.95 Rubber, glossy 0.94 Black Silicone Paint 0.93 Lead un-oxidized 0.057-0.075 Rubber, natural hard Black Epoxy Paint 0.89 Lead Oxidized 0.43 Salt 0.34 Black Enamel Paint 0.8 Limestone 0.90-0.93 Sand 0.76 Brass Dull Plate 0.22 Magnesite 0.38 Sandstone 0.59 Brass Polished 0.03 Magnesium Polished Emissivity 0.91 0.07-0.13 Silica 0.79 Brick, red rough 0.93 Marble White 0.95 Silicon Carbide 0.83-0.96 Brick, fireclay 0.75 Masonry Plastered 0.93 Silver Polished 0.02-0.03 Carbon, not oxidized 0.81 Mercury liquid 0.1 Soil 0.90-0.95 Cast Iron 0.44 Mild Steel 0.20-0.32 Steel Oxidized 0.79 Cement 0.54 Mortar 0.87 Steel Polished 0.07 Clay 0.91 Nickel, electroplated 0.03 Stainless Steel(SS) Coal 0.8 Nickel, polished 0.072 SS, polished 0.075 Concrete 0.85 Nickel, oxidized 0.59-0.86 Steel Galvanized old Concrete, rough 0.94 Oak, planed 0.89 Steel Galvanized New Concrete tiles 0.63 Oil paints, all colors 0.85 0.88 0.23 0.92-0.96 Tile 0.97 Cotton cloth 0.77 Paper offset 0.55 Tin un-oxidized 0.04 Copper Polished 0.023-0.052 Plaster 0.98 Water 0.95-0.963 Copper Nickel Alloy 0.059 Pine 0.84 Wood Beech, planned Glass smooth 0.92-0.94 Plaster board 0.91 Wood Oak, planned 0.935 0.885 Glass, Pyrex 0.85-0.95 Porcelain, glazed 0.92 Wood, Pine 0.95

CLEANING AND STORAGE Clean the thermometer housing and the lens using only a soft cloth or cotton swab with water or medical alcohol. Do not let any liquid enter the case or sensor area. Allow the lens to fully dry before using the thermometer. Avoid storing the unit in extreme temperature conditions. Do not store below -4 F, or where the radiant temperature may exceed 140 F. SPECIFICATIONS Range -28 C~482 C/-20 F~900 F Accuracy 0~482 C : ± 2 C AND -28 ~0 C: ± 4 C 32~900 F : ± 4 F AND -20~32 F : ± 7 F Resolution 0.1 C (0.1 F) Response Time Time 500ms Emissivity Adjustable 0.1~1.0 Distance To Spot(D:S) 11:1 Spectral Response 8~14um Diode Laser Class II,Power<1mW, Wavelength 630~670nm Auto Power Off After 60 seconds of inactivity Operating Temp. 0 C to 50 C / 32 F to 122 F Storage Temp. -20 C to 60 C / -4 F to 140 F Relative Humidity(RH) 10~95%(Operating),<80%(Storage) Power Supply 2 pc. AA battery Battery Life Typical 65 hours continuous use Dimensions (L*W*H) 155.5*98.8*27.5mm Weight 185g ± 0.2g (with battery) * IMPORTANT: Under adverse conditions (such as bright solar light outdoors or in the surrounding environment, weak reflection of the surface to be measured, and rough surface) measurement error can occur. 9

1 YEAR LIMITED WARRANTY Express and Exclusive Limited Warranty to Original Retail Buyer Every ALLTRADE product is inspected before leaving the factory. This product is warranted to be free of defects in material and workmanship for a period of one year from the date of original purchase. If a defect appears within one year after the date of purchase, the purchaser may return the item, together with a purchase receipt or other appropriate proof of purchase to the place of purchase. Upon receipt of the item(s), the place of purchase will, at its option, replace the defective item or refund your money. This warranty shall not apply when the product has been used for commercial or rental purposes, has been tampered with, when repairs or attempted repairs have been made by unauthorized persons, or where the item has been subjected to misuse, abuse, accident or damage in transit. No charges will be accepted for unauthorized parts, repairs or services. IN NO EVENT SHALL ALLTRADE BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES. Some provinces do not allow limitations on how long an implied warranty lasts and some states do not allow the exclusion or limitation of the incidental or consequential damages, so part or all of the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from province to province. FCC INFORMATION Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and the receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/tv technician for help. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. 10

Official Licensed Product. Vaughan is a registered trademark of Vaughan & Bushnell Mfg. Co. All rights reserved. FOR CUSTOMER SERVICE 1-800-423-3598 Printed in China Distribution & Returns 2017, Alltrade Tools, LLC Reno, NV 89508 www.vaughangear.com MADE IN CHINA