Signal Level Considerations For Remote Diffuse Reflectance Analysis

Similar documents
Introduction to Fourier Transform Infrared Spectroscopy

Introduction to Fourier Transform Infrared Spectroscopy

Detection of trace contamination on metal surfaces using the handheld Agilent 4100 ExoScan FTIR

Section 22. Radiative Transfer

Section 10. Radiative Transfer

Chemistry Instrumental Analysis Lecture 15. Chem 4631

Solar irradiance measurement up to 2500nm with the Arcoptix FT-NIR

Application of Raman Spectroscopy for Noninvasive Detection of Target Compounds. Kyung-Min Lee

Absorbance Linearity and Repeatability in Cylindrical Internal Reflectance FT-IR Spectroscopy of Liquids

Measuring Laser Diode Optical Power with an Integrating Sphere

HYDROBETA: A NEW INSTRUMENT FOR MEASURING IN-SITU PROFILES OF THE VOLUME SCATTERING FUNCTION FROM 10 TO 170 DEGREES

Fundamentals of nanoscience

Introduction to FT-IR Spectroscopy

Integrating Spheres in Molecular Spectrophotometry

Modern Techniques in Applied Molecular Spectroscopy

Let us consider a typical Michelson interferometer, where a broadband source is used for illumination (Fig. 1a).

Advanced Spectroscopy Laboratory

Fourier Transform Infrared. Spectrometry

DOWNLOAD OR READ : INFRARED AND RAMAN SPECTROSCOPY CONCEPTS AND APPLICATIONS PDF EBOOK EPUB MOBI

Which Optistat is right for you?

EE/Ge 157 a SYSTEMS FOR REMOTE SENSING FROM SPACE Week 3: Visible and Near IR 3-1

Whole Tablet Measurements Using the Frontier Tablet Autosampler System

Making Accurate Field Spectral Reflectance Measurements By Dr. Alexander F. H. Goetz, Co-founder ASD Inc., Boulder, Colorado, 80301, USA October 2012

IR SPECTROSCOPY FOR BONDING SURFACE CONTAMINATION CHARACTERIZATION

10. OPTICAL COHERENCE TOMOGRAPHY

FTIR Spectrometer. Basic Theory of Infrared Spectrometer. FTIR Spectrometer. FTIR Accessories

TECHNICAL GUIDE. Integrating Sphere Radiometry and Photometry

EXPERIMENTAL DETERMINATION OF SPECTRAL AND ANGULAR DEPENDENT OPTICAL PROPERTIES OF INSULATING GLASSES

Vibrational Spectroscopies. C-874 University of Delaware

Influence of sun radiation on results of non-contact temperature measurements in far infrared range

INTRODUCTION TO MICROWAVE REMOTE SENSING. Dr. A. Bhattacharya

What happens when light falls on a material? Transmission Reflection Absorption Luminescence. Elastic Scattering Inelastic Scattering

Near-Infrared Spectroscopy of Nitride Heterostructures EMILY FINAN ADVISOR: DR. OANA MALIS PURDUE UNIVERSITY REU PROGRAM AUGUST 2, 2012

Chemistry 524--Final Exam--Keiderling Dec. 12, pm SES

PAPER No. 12: ORGANIC SPECTROSCOPY MODULE No. 7: Instrumentation for IR spectroscopy

AS 101: Day Lab #2 Summer Spectroscopy

Lecture 20 Optical Characterization 2

Quantitative determination of common types of asbestos by diffuse reflectance FTIR using the Agilent Cary 630 Spectrometer

Chemical Composition Monitoring Using An In-Situ Infrared Probe

CHAPTER-VI DISCUSSION. CONCLUSION AND FUTURE SCOPE OF THE PRESENT WORK

BETTER DESIGN AND NEW TECHNOLOGIES IMPROVE LASER POWER MEASUREMENT INSTRUMENTATION

Application of Raman Spectroscopy for Detection of Aflatoxins and Fumonisins in Ground Maize Samples

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

Investigation of H 2 :CH 4 Plasma Composition by Means of Spatially Resolved Optical Spectroscopy

Regular Reflectance and Transmittance Measurements of Transmissive Materials Using a STAR GEM Optical Accessory

Presentation of a solar reflectometer coupled with a solar concentrator

Optical Gain and Multi-Quantum Excitation in Optically Pumped Alkali Atom Rare Gas Mixtures

Lecture 2 Overview of Light in Water

Milk Analysis with the TIDAS P Milk Inspector

Transvision: a Light Transmission Measurement System for Greenhouse Covering Materials

Fresnel Equations cont.

Ultra-narrow-band tunable laserline notch filter

Radiometry. Basics Extended Sources Blackbody Radiation Cos4 th power Lasers and lamps Throughput. ECE 5616 Curtis

Fourier Transform Infrared Spectrometry

Ms. Monika Srivastava Doctoral Scholar, AMR Group of Dr. Anurag Srivastava ABV-IIITM, Gwalior

Simplified Collector Performance Model

University of Cyprus. Reflectance and Diffuse Spectroscopy

Richard Miles and Arthur Dogariu. Mechanical and Aerospace Engineering Princeton University, Princeton, NJ 08540, USA

Reflection = EM strikes a boundary between two media differing in η and bounces back

Whole Tablet Measurements Using the Spectrum One NTS Tablet Autosampler System

Lecture 2: principles of electromagnetic radiation

Mid-IR Methods. Matti Hotokka

High-Resolution Imagers

Analysis of Thermal Diffusivity of Metals using Lock-in Thermography

Spectroscopic techniques: why, when, where,and how Dr. Roberto GIANGIACOMO

CHIRON efficiency. A. Tokovinin. Version 2. March 28, 2011 file: prj/bme/chiron/commissioning/efficiency.tex

exp ( κh/ cos θ) whereas as that of the diffuse source is never zero (expect as h ).

Infrared Spectroscopy: Identification of Unknown Substances

Lecture 19 Optical MEMS (1)

Spectroscopy tools for PAT applications in the Pharmaceutical Industry

Chapter 24 Photonics Question 1 Question 2 Question 3 Question 4 Question 5

Plastic Coated Silica/Silica (Low OH) FIBER CROSS SECTION Polyimide and Acrylate Coated. Nylon and Tefzel Coated

Dr. Linlin Ge The University of New South Wales

PTG-NIR Powder Characterisation System (not yet released for selling to end users)

Supporting Information s for

On the possibility to create a prototype of laser system for space debris movement control on the basis of the 3-meter telescope.

Lecture 7: Optical Spectroscopy. Astrophysical Spectroscopy. Broadband Filters. Fabry-Perot Filters. Interference Filters. Prism Spectrograph

Vector diffraction theory of refraction of light by a spherical surface

Analysis of the signal fall-off in spectral domain optical coherence tomography systems

Imagent for fnirs and EROS measurements

BIO & PHARMA ANALYTICAL TECHNIQUES. Chapter 5 Particle Size Analysis

Department of Electrical and Computer Engineering, Cornell University. ECE 5330: Semiconductor Optoelectronics. Fall 2014

Multiphysics Simulation of Polymer-Based Filters for Sub-Millimetre Space Optics

Polarization. Polarization. Physics Waves & Oscillations 4/3/2016. Spring 2016 Semester Matthew Jones. Two problems to be considered today:

Temperature-dependent spectroscopic analysis of F 2 + ** and F 2 + **-like color centers in LiF

Blackbody radiation. Main Laws. Brightness temperature. 1. Concepts of a blackbody and thermodynamical equilibrium.

Determining how uncertainties in optical properties affect light dose calculations

Glossary. Analyte - the molecule of interest when performing a quantitative analysis.

Smart Sensing Embedded Spectroscopy Platform Botlek studiegroep 06-april-2017

HYPERSPECTRAL IMAGING

CONFOCHECK. Innovation with Integrity. Infrared Protein Analysis FT-IR

2 Experimental section. 1 Introduction MEASUREMENT OF SOLAR ABSORPTANCE OF MAP THERMAL-CONTROL COATINGS

The Effects of Hydrazine Monohydrate Surface Doping on Graphene

Radiation and the atmosphere

Light Scattering in Inhomogeneous Atmospheres

A Guide to Integrating Sphere Theory and Applications

IR Spectrography - Absorption. Raman Spectrography - Scattering. n 0 n M - Raman n 0 - Rayleigh

Applied Spectroscopy Spectroscopic Nomenclature

Resonantly Pumped Er:YAG and Er:YAP Lasers

Small Signal Gain in DPAL Systems

Transcription:

TECHNICAL NOTE: AN-916 (Rev. B) (Feb. 28, 2012) Signal Level Considerations For Remote Diffuse Reflectance Analysis W. M. Doyle Axiom Analytical, Inc INTRODUCTION: Near infrared (NIR) spectroscopy has a long history as a quality control technique for the analysis of granular scattering substances such as agricultural products. The instruments used have generally been designed to maximize collection efficiency and hence have used either internal sample compartments or optical coupling by means of large diameter fiber-optic bundles. As a result, such instruments must be located close to the sampling point. Chemical process applications present a new combination of requirements. In particular, the sample streams are often fluids containing scattering centers rather than granular solids. In addition, the process stream is often remote from the instrument, making it necessary to transmit the near-ir radiation to and from the measurement point by means of single optical fibers or economical small-diameter fiber bundles. The present paper reviews the theoretical information needed to maximize the received signal level in the application of diffuse reflectance to remote on-line process analysis. A second paper (now in production) will consider the behavior of the diffusely reflecting systems involving the inhomogeneous mixtures common to many process applications. Both of these papers are extensions of work previously published (Ref. 1). BASIC RADIATION TRANSFER CONSIDERATIONS: For this discussion, we will make a few simplifying assumptions. While these may reduce the accuracy of calculated signal levels, they should not effect our overall goal, which is to provide a framework for optimizing system performance. Our primary assumptions are first that all optical elements are axially symmetric and, second, that a given signal level is constant across a specified area of illumination. The signal level obtained in a remote diffuse reflectance installation is limited by the fact that a diffusely reflecting sample scatters light into a full hemisphere, while the fiber-optic coupled probe necessarily has a limited collecting aperture and field of view. In general, the total optical power collected by an optical probe viewing a diffuse source of radiation is equal to P c = N t cos d da (Eq. 1) Here, N t is the radiance of the target. Radiance is defined as the power radiated by the source, in a specific direction, per unit area and solid angle (Ref. 2). For an ideal diffuse (Lambertian) radiator, N is independent of angle, and we can write 1

P c = cos d N t da = sin 2 c N t da (Eq. 2) Where c is the half angle field of view of the collecting optics, centered on the normal to the target surface. (See Figure 1.) Using our assumption that the radiance is spatially uniform across the area being viewed, we perform the integral in Equation 2 and write passing through the aperture. (See Figure 2.) Using this definition, we can now rewrite Equation 3 as P c = c N t (Eq. 5) Where c is the throughput of the collection Max Beam Divergence ( a ) P c = sin 2 c N t c Where c = viewed area (Eq. 3) Note that most diffusely reflecting samples will approximate a Lambertian radiator for illumination within typically 40 o of normal incidence (Ref.3). da Figure 1. Signal Collection Geometry GEOMETRIC THROUGHPUT CONSIDERATIONS Radiation transfer calculations can often be simplified by introducing the concept of Throughput (Ref. 4). The Throughput of any circular aperture in an optical system is given by: a asin 2 a (Eq. 4) where A a is the area of the aperture, and a is the maximum divergence angle of radiation d optics. Figure 2: Throughput Definitions Aperture (Area = A a ) Throughput is often confused with transmission. However, throughput is strictly a geometric quantity whereas transmission is concerned with the various losses of a system caused by such factors as absorption and reflection. Much of the value of throughput is embodied in the Conservation of Throughput Principle. This states that the throughput of an optical system can be no greater than the lowest throughput of any aperture in the system. Thus, once we have determined the minimum (or limiting ) throughput of a system, we can use to estimate performance under various conditions. By invoking the conservation of throughput principle, we can now replace Equation 5 by P c = LN t (Eq. 6) where L is the limiting throughput of the system. In the case where the limiting 2

throughput is determined by the collection optics we have L = c. To obtain an expression for the radiance, N t, we can take advantage of the fact that the total reflected power is scattered into 180 o. For a Lambertian reflector, we can thus write P t = N t, where = A I, (Eq. 7) Here, P t is the total reflected power, i.e. the incident power, P I, times the reflectance of the target (assumed to be constant), A I is the illuminated area and can be thought of as the Lambertian equivalent throughput. Thus, if A c < A I, P c = ( L/ )P t L A I P t (Eq. 8) By a similar development, we can show that, if A c > A I, Equation 8 will still be valid if we change A I to A c. We thus can generalize this equation to P c L A e P t, (Eq. 9) Where A e is the greater of A I or A c. Thus (NA) fr = sin fr. (Eq. 11) fr = fr(na) fr 2. (Eq. 12) Substituting Equation 12 into Equation 10 yields a simple expression for the collected power in terms of known quantities, i.e: where, P c = ( fr/ e) (NA) fr 2 P t (Eq. 13) fr = optical area of the receiving fiber or fiber bundle e = the larger of the illuminated or viewed area (NA) fr = numeric aperture of the fiber P t total power scattered by the Lambertian target. So far we have only considered the geometrical aspects of signal collection. We now generalize Equations 9 and 13 to take into consideration the various losses in the system. APPLICATION TO A FIBER-OPTIC COUPLED PROBE For most fiber-optic coupled systems, the fiber cable will present the limiting throughput, i.e. L = fr and P c fr A e P t, (Eq. 10) where fr = frsin 2 fr, and A fr is the optical area of the fiber. Fiber throughput can be expressed in terms of the numeric aperture (NA) fr of the fiber. This is defined as Here, P r = d r R t T r ( L/ A e )P (Eq. 14) P r = d r R t T r ( fr/ e)(na) fr 2 P I. (Eq. 15) P r = received power at the detector P I = incident power at the target d r = core packing density of the receiving fiber bundle R t = target reflectance 3

T r = overall receiving system transmission on axis L = the limiting throughput of the system. TARGET ILLUMINATION To estimate the power transmitted from the source of radiation to the surface of the target, we can again invoke the conservation of throughput principle. The considerations are similar to those considered above. Assuming that the source is larger than the field of view of the collecting optics, the total power collected will be given by P s = s N s (Eq. 16) Where s is the throughput of the source collecting optics and N s is source radiance. Just as in the case of the receiving system, the transmitted power will be dependent on the limiting throughput of the system. If the transmission system employs fiber optics, its throughput will generally be the determining factor. In this case s will be replaced by ft the throughput of the transmitting fiber bundle. The total power delivered to the target will then be Where, P I = d t T t Lt N s (Eq. 17) d t = core packing density of the transmitting fiber bundle T t = overall transmitting system transmission on axis Lt = the limiting through put of the transmitting system N s = source radiance or, P I = d t T t A ft (NA) ft 2 N s (Eq. 18) where, A ft = optical area of the transmitting fiber or fiber bundle (NA) ft = numerical aperture of the transmitting fiber. Combining Equations 15 and 18 gives an overall expression for the signal obtained in a diffuse reflectance system employing optical fibers for both transmission and reception: P r = d r d t R t T r T t ( fra ft / e)(na) fr 2 (NA) ft 2 N s. (Eq. 19) THEORETICAL MAXIMUM SIGNAL FOR AN OPTIMUM PROBE DESIGN As a specific example, we will consider an idealized probe system employing a bifurcated fiber bundle with equal numbers of randomized illuminating and receiving fibers. For a typical bundle, we can expect (NA) = 0.22 and a packing density for all fibers of d = 0.55. Thus, for the bifurcated case, we have d r = 0.275. In addition, we will assume the ideal case in which R t = T r = 1. Substituting these values in Equation 15 yields Where, again P r = 0.0133 ( fr/ e)p I (Eq. 20) P r = received power P I = incident power at the target. Using the same set of assumptions for the transmitting portion of the system, we have 4

P I = 0.0418 A ft N s. (Eq. 21) And finally, since fr = ft f, P r = 5.56x10-4 ( f 2 / e)n s. (Eq. 22) This example illustrates two important points: First, the total signal power available is proportional to the area of the receiving fiber times the area of the transmitting fiber. This is a consequence of the fact that the diffuse reflectance process destroys the spatial coherence of the signal. Thus, the target must be considered as a new Lambertian source having a total power determined by the signal transmitted from the original source. Second, the available power is inversely proportional to the effective area of the target (i.e the greater of the illuminated or viewed areas). CONCLUSIONS AND IMPLICATIONS FOR SYSTEM DESIGN This paper has provided a simple framework for estimating the signal levels to be expected in the design of fiber-optic coupled diffuse reflectance sampling systems. It illustrates the fact that the performance obtained is ultimately limited by the area and numeric aperture of the fiber cables used for both illumination and detection. In addition, there is an inherent trade-off between signal level and illuminated area. In practice, the problem of limited fiber throughput is mitigated to a certain extent by the extremely high sensitivities of the InGaAs detectors now available for us in the near-ir spectral region. However, for many applications, there is marked trade-off between cost and performance. This is particularly true when long fiber runs are required or when granularity of the samples necessitates a large illuminated area. From Equations 15 and 18, it is clear that for a given illuminated and view area, the signal level in the ideal case can only be increased by increasing the areas of the receiving and/or transmitting fibers or by increasing the source power. However, for many spectroscopic analyzers, other limitations will soon come into play even if the economics allows an increase in fiber area. For example, rapid scanning systems such as FTIR spectrometers require high speed detectors, which are generally not available in large areas. In addition, the throughput of the spectrometer optics can be a significant limitation. One possibility for increasing performance is to include both of the elements with inherently limited throughput (i.e. the spectrometer optical system and detector subsystem) in the same leg of the analysis system. This enables the signal level in the illuminating portion of the system to be increased by maximizing fiber-optic throughput and possibly source intensity. In the extreme case, the source can be located close to the measurement point. In this case it may be practical and economical to use a large fiber bundle or to eliminate the transmitting fibers completely. However, for many process applications this would require an intrinsically safe, and hence expensive, source subsystem. Despite the limitations of remote fiberoptic coupled diffuse reflectance analysis, there are many situations in which the benefits greatly outweigh the difficulties. This field is still at an early stage of implementation. However, it offers promise for a number of different areas of application, and there is yet much that can be done to match performance to the needs of the various requirements. 5

REFERENCES: 1. W. M. Doyle, Remote Diffuse Reflectance Analysis for Process Applications, in: Proceedings of the Conference on Spectroscopy in Process and Quality Control, East Brunswick NJ, June 7-8, 1999. 2. W. L. Wolf, (Ed.), Handbook of Military Infrared Technology, Office of Naval Research, Washington DC. 1965, p. 22. 3. Gustav Kortuem, Reflectance Spectroscopy, Springer-Verlag, Berlin, p. 33. 4. W. L. Wolf and G. J. Zissis (Eds.), The Infrared Handbook, prepared by the Environmental Research Institute of Michigan for the Office of Naval Research. Washington DC. 1978, p. 20-8. 6