Robust ICP-MS with ease of use and high productivity for routine laboratories

Similar documents
Redefining triple quadrupole technology with unique ease of use

Determination of ultratrace elements in photoresist solvents using the Thermo Scientific icap TQs ICP-MS

Thermo Scientific icap RQ ICP-MS: Typical limits of detection

Thermo Scientific icap TQ ICP-MS: Typical limits of detection

Simplified workflows for the Thermo Scientific icap TQ ICP-MS

Analysis of high matrix samples using argon gas dilution with the Thermo Scientific icap RQ ICP-MS

Agilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS)

Total Elemental Analysis of Food Samples for Routine and Research Laboratories, using the Thermo Scientific icap RQ ICP-MS

Thermo Scientific ICP-MS solutions for the semiconductor industry. Maximize wafer yields with ultralow elemental detection in chemicals and materials

Automated, intelligent sample preparation: Integration of the ESI prepfast Auto-dilution System with the Thermo Scientific icap 7400 ICP-OES

Total elemental analysis of food samples for routine and research laboratories using the Thermo Scientific icap RQ ICP-MS

Basic and Application Inductively coupled plasma mass spectrometry (ICPMS)

Defining quality standards for the analysis of solid samples

Accurate measurement of elemental impurities in metals and metal alloys using the Thermo Scientific icap TQ ICP-MS

Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry

ICP-MS. High Resolution ICP-MS.

Key Words Nanoparticles, spicp-ms, ICP-MS, Qtegra ISDS Software, AF4-ICP-MS

Thermo VG PQ EXCELL INDUCTIVELY COUPLED PLASMA MASS SPECTROMETER

Handling Interferences in the Modern Laboratory with Advanced Triple Quadrupole ICP-MS Technology

Determination of Impurities in Silica Wafers with the NexION 300S/350S ICP-MS

Fergus Keenan Shona McSheehy Julian Wills

Direct Analysis of Trace Metal Impurities in High Purity Nitric Acid Using ICP-QQQ

Advanced ICP-MS techniques for overcoming interferences in LA-ICP-MS bioimaging

ELEMENT2 High Resolution- ICP-MS INSTRUMENT OVERVIEW

Enhancing the productivity of food sample analysis with the Agilent 7700x ICP-MS

- A spark is passed through the Argon in the presence of the RF field of the coil to initiate the plasma

Determination of trace elements in ultrapure semiconductor grade sulfuric acid using the Agilent 8900 ICP-QQQ in MS/MS mode

Agilent s New 8800 ICP-QQQ. Transforming ICP-MS Technology

TOXICOLOGY & FORENSIC APPLICATIONS

High-Speed Environmental Analysis Using the Agilent 7500cx with Integrated Sample Introduction System Discrete Sampling (ISIS DS)

Following documents shall be used for reference on quantities, units, prefixes and other technical vocabulary in this document:

Insights Into the Nanoworld Analysis of Nanoparticles with ICP-MS

Ultra-fast determination of base metals in geochemical samples using the 5100 SVDV ICP-OES

Thermo Scientific ELEMENT GD PLUS Glow Discharge Mass Spectrometer. Defining quality standards for the analysis of solid samples

Rapid Analysis of High-Matrix Environmental Samples Using the Agilent 7500cx ICP-MS. Application. Author. Abstract. Introduction.

IRMS. perspective. Isotope Ratio Mass Spectrometry.

Analysis of Trace Metal Impurities in High Purity Hydrochloric Acid Using ICP-QQQ

Ultra trace measurement of potassium and other elements in ultrapure water using the Agilent 8800 ICP-QQQ in cool plasma reaction cell mode

Multi-Element Analysis of Petroleum Crude Oils using an Agilent 7900 ICP-MS

Direct Measurement of Metallic Impurities in 20% Ammonium Hydroxide by 7700s/7900 ICP-MS

Applications of ICP-MS for Trace Elemental Analysis in the Hydrocarbon Processing Industry

Overcoming Interferences with the Thermo Scientific icap 7000 Plus Series ICP-OES

PERSPECTIVE STABLE ISOTOPE RATIO MS

Agilent 8800 ICP-QQQ

Determination of challenging elements in ultrapure semiconductor grade sulfuric acid by Triple Quadrupole ICP-MS

Thermo Scientific LTQ Orbitrap Velos Hybrid FT Mass Spectrometer

novaa 800 D Atomic Absorption Spectrometer

Thermo Finnigan LTQ. Specifications

Agilent 8900 Triple Quadrupole ICP-MS

Analysis of noble metals at low levels in geological reference materials and ores

PERSPECTIVE STABLE ISOTOPE RATIO MS

The ultratrace determination of iodine 129 in aqueous samples using the 7700x ICP-MS with oxygen reaction mode

Extrel is widely respected for the quality of mass spectrometer systems that are

Today s Agilent Solutions for Determining Heavy Metals in Food using Atomic Spectroscopy

Introducing the Agilent 7000A QQQ-MS for GC Sunil Kulkarni Product Specialist Agilent Technologies

OES - Optical Emission Spectrometer 2000

The 30-Minute Guide to ICP-MS

Finnigan LCQ Advantage MAX

Atomic Spectroscopy AA/ICP/ICPMS:

HELIX MC Plus. Static Vacuum. ARGUS VI Thermo Scientific HELIX MC Plus Static Vacuum Mass Spectrometer Static Vacuum Mass Spectrometer

HELIX SFT. Static Vacuum ARGUS VI HELIX SFT. Static Vacuum Mass Spectrometer Static Vacuum Mass Spectrometer

of mass spectrometry

High Throughput Water Analysis using Agilent 7900 ICP-MS coupled with ESI prepfast

Simple, reliable analysis of high matrix samples according to US EPA Method 6020A using the Agilent 7700x/7800 ICP-MS

Agilent 7500 Series ICP-MS

881 Compact IC pro / 882 Compact IC plus for ion chromatography. Intelligent. Reliable. Precise.

Atomic Absorption Spectrometer ZEEnit P series

Achieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer

The Agilent 7700x ICP-MS Advantage for Drinking Water Analysis

BECKMAN COULTER QbD1200 Total Organic Carbon Analyzer Critical Measurements Made Simple

Determination of Carbon d13c isotopic composition from DIC samples

Analysis of trace elements in polymer samples to ensure compliance with WEEE-RoHS standards using the Thermo Scientific icap 7200 ICP-OES

Determination of Nanoparticle Sizeand Number Concentration using the npquant Evaluation Module for Qtegra ISDS. The world leader in serving science

ARGUS VI. Static Vacuum Mass Spectrometer. Static Vacuum ARGUS VI. Multicollection Low Volume Precision

881 Compact IC pro 882 Compact IC plus. Compact ion chromatography for intelligent, reliable and precise analysis

Trace elemental analysis of distilled alcoholic beverages using the Agilent 7700x ICP-MS with octopole collision/ reaction cell

Ideal and powerful solution

Comparing Collision/Reaction Cell Modes for the Measurement of Interfered Analytes in Complex Matrices using the Agilent 7700 Series ICP-MS

Techniques for the Analysis of Organic Chemicals by Inductively Coupled Plasma Mass Spectrometry (ICP-MS)

Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma

Hydride Generation for the Determination of As, Sb, Se and Bi Using the Teledyne Leeman Lab s Prodigy 7 ICP-OES

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

883 Basic IC plus. The smallest Metrohm ion chromatograph

Introduction to Fourier Transform Infrared Spectroscopy

Quadrupole Time-of-Flight Liquid Chromatograph Mass Spectrometer LCMS-9030 C146-E365

Agilent ICP-MS. Fundamentals of ICP-MS Analysis and Its Applications for Low Level Elemental Determination in Cannabis

Translational Biomarker Core

Rapid and precise calcium isotope ratio determinations using the Apex-ACM desolvating inlet system with sector-field ICP-MS in low resolution

Agilent 8900 Triple Quadrupole ICP-MS LEAVE INTERFERENCES BEHIND WITH MS/MS

Automated Determination of PPQ Levels of Thorium in High Purity Copper

DI 3500 Discrete Aoalvzer

Application note. Trace level analysis of sulfur, phosphorus, silicon and chlorine in NMP using the Agilent 8800 Triple Quadrupole ICP-MS

Elemental Analysis: NCS characterization of paper

Trace Analyses in Metal Matrices Using the ELAN DRC II

Spectrometric Methods of Analysis. OCN 633 Fall 2013

Implementing EPA Method 6020 with the Agilent ICP-MS Portfolio

Expanded capabilities in ammonium and amine detection

Nanoparticle Analysis: An Upcoming Challenge for Environmental Analysis

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment LCQ Deca XP Plus

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer

Transcription:

PRODUCTION SPECIFICATIONS Thermo Scientific icap RQ ICP-MS with XS Robust ICP-MS with ease of use and high productivity for routine laboratories Benefits User-friendly operation. Simple method development with comprehensive interference removal. Reduced user maintenance with improved matrix tolerance. Accelerated productivity with fully integrated sample handling solutions. Keywords Ease of use, elemental analysis, comprehensive interference removal, productivity The Thermo Scientific icap RQ ICP-MS is built for total reliability, advanced performance and assured accuracy. A design inspired by real laboratory needs, simplifies the user experience and dramatically improves productivity and efficiency. This innovative single quadrupole (SQ) ICP-MS analyzer is the ideal solution for a wide range of sample types and industries; from demanding 24/7 routine analysis to advanced applications in research. User-friendly Thermo Scientific Qtegra ISDS Software manages entire workflows from Get Ready to data reporting. This intuitive software platform is common to other Thermo Scientific trace elemental techniques, so operators can seamlessly switch between instruments. Assure your applications with the reliability, robustness and analytical performance demanded by high-throughput, routine laboratories.

icap RQ ICP-MS with XS hardware summary Sample introduction The bench height sample introduction system is positioned to optimize user accessibility to all parts. Spraychamber Peltier cooled high purity quartz or PFA, low-volume, baffled cyclonic spraychamber, efficiently filters out larger aerosol droplets for improved plasma stability. Reduced surface area improves sample washout. Compatible with all 6 mm OD nebulizers. Nebulizer High performance, concentric nebulizers with ~0.4 ml min -1 sample consumption. Optional nebulizers in a range of flow rate sizes, total dissolved solids tolerance and suitability for organics or HF. Torch Push-in, demountable single piece quartz torch. All connectivity (argon gas supplies and plasma ignition) designed into the holder, reducing torch complexity and improving usability. Proprietary, screw-in, self-aligning injector for ease of use and reliability. Peristaltic pump Compact, low pulsation, 12 roller, four channel mini-pump with inert rollers for improved reliability. Additional gas kits Two additional mass flow controllers (0-250 or 0-1000 ml min -1 ) available as options. Coupled closely to the sample introduction system with quick fit connectivity. Fully software controlled allowing for introduction of gases into the spraychamber (e.g. O 2 for the analysis of organic solvents or Ar for Gas Dilution) or to supply gases for coupled accessories (for example He during Laser Ablation). Inductively coupled plasma The icap RQ ICP-MS plasma is designed to rapidly adapt to changing matrices and provide unparalleled robustness even for challenging samples such as highly volatile organic solvents. RF generator Digital, solid state RF generator operating with dynamic frequency impedance matching the plasma at ~27 MHz. Low ion energy spread for optimum ion focusing and transmission, without the need of a grounded shield between torch and load coil. Highly stable and robust cold plasma operation. Load coil Water cooled load coil for improved lifetime and reliable plasma ignition. Accessible at bench height for ease of maintenance. Plasma TV Remote monitoring of plasma status via integrated HD camera. Interface Unique front opening interface provides rapid, simultaneous access to cones and extraction lens, to facilitate routine maintenance and minimize downtime. Cones Optimized sample (1.1 mm diameter orifice) and skimmer (0.5 mm diameter orifice) cone geometries for reduced matrix deposition and maintenance. Ni cones as standard; Pt tipped as option for specialized applications. Cones are rapidly removed by a single (magnetic) tool. Proprietary skimmer insert design reduces memory effects and a range of inserts allows the user to balance the needs of matrix resistance against absolute sensitivity. Robust Interface specifically designed for minimal drift during long-term analysis of high matrix samples. High Matrix Interface for typical sample types provides the optimal balance between sensitivity and tolerance. High Sensitivity Interface provides excellent signal to noise ratio for ultratrace analysis and advanced applications. 2

Extraction lens Single extraction lens operated at low voltages for optimum ion extraction and focusing into the ion optics bayonet mounted for easy handling. Slide valve Software controlled: defaults to closed position when plasma is off or in the event of a power failure, maintaining vacuum in the analyzer housing. Ion optics Unique 90 cylindrical ion lens the RAPID lens: Right Angular Positive Ion Deflection, providing high ion transmission across the entire mass range. RAPID lens dimensions significantly larger than ion beam and neutrals, eliminates lens cleaning maintenance. Off-axis design delivers class-leading background noise. Electrical connections with gold spring contacts from the analyzer housing to ions optics improve reliability. QCell collision/reaction cell (CRC) Zero maintenance, small volume collision/reaction cell with proprietary flatapole rods. Turbo pump Single split flow turbo molecular pump. Interface pump External, high performance pump to provide backing to the turbo pump and evacuation of the expansion region for improved sampling from the plasma. Supplied with synthetic, chemically stable, temperature resistant rotary pump oil as standard. Detector Long lifetime detector designed for ICP-MS requirements. Dwell times of 100 μs in both analog and counting detection modes. Linear dynamic detection range: > 10 orders of magnitude. Automated optimization of operating voltages and cross-calibration. Cradle design for ease of detector exchange. High transmission, even in He KED mode, enabling complete single measurement mode analysis of all analytes including Li and Be. Low mass cut off for improved interference reduction than KED alone. Choice of 1 or 2 gas specific mass flow controllers for He and flexibility to work with reactive gases such as H 2, O 2, or a mixture of NH 3 /He. Quadrupole Quadrupole mass analyzer driven by a solid state, 2 MHz supply ensure low abundance sensitivity and class leading mass stability. User definable mass resolution in the mass range 2-225 u. Fixed mass resolution and Extended Sensitivity (XS) in the mass rnage 225-290 u. Mass calibration assessed and automatically updated. Vacuum system High vacuum is maintained in the event of a power failure: the rotary and turbo pumps automatically restart as soon as power is restored. A stable vacuum, obtained in less than 15 minutes pumping time, enables fast return to service after routine maintenance. 3

icap RQ ICP-MS with XS configuration and performance specifications Configuration Nebulizer Spraychamber Torch Injector Cones/Interface Digitally Controlled Plasma Gas Flows Additional Mass Flow Controllers (e.g. O 2 for organics, He for laser) Glass, concentric Quartz, cyclonic Quartz, demountable, no shield Quartz, 2.5 mm ID Ni, high matrix interface Three Optional (Two) icap RQ Configurations C1 C2 He Cell Gas MFC Yes Yes Additional Cell MFC e.g. H 2, O 2 etc. *FUO Yes STD Mode 7 Li 55 Sensitivity (kcps/ppb) b 59 Co 100 115 In 2 238 U c 0 9 Be < 0.5 Detection Limits (ppt) a 115 In < 0.1 209 Bi < 0.1 Oxides (%) b CeO/Ce < 2 Doubly Charged (%) b Ba ++ /Ba + < 3 Background (cps) b m/z 4.5 < 1 Stability (%RSD) Short Term b < 2 (10 min) Long Term < 3 (2 h) Isotope Ratio Precision (%RSD) 107 Ag/ 109 Ag < 0.1 He KED Mode Sensitivity (kcps/ppb) b Co 30 Background (cps) b m/z 4.5 < 0.5 * FUO - Field upgrade option. a Typical values, dependent on cleanliness of chemicals. b Demonstrated on installation; Uranium sensitivity of 330 kcps/ppb is demonstrated on installation. c Uranium XS sensitivity specification is not qualified in the performance report criteria during installation. Note that installation specifications are only conducted with the default sample introduction components listed in the Table above. 4

icap RQ ICP-MS with XS hardware specifications Sample Introduction Access Peristaltic Pump Nebulizer Spraychamber Bench height, torch axis parallel to bench, minimized distances Software controlled 12 roller, 4 channel mini-pump, inert rollers, low pulsation Three stop flared PVC pump tubing as standard Concentric borosilicate glass with 0 μl min -1 flow rate; PFA and high TDS optional Baffled cyclonic, high purity quartz; PFA optional Compatibility with all 6 mm OD nebulizers Peltier Cooler Software control in range 10 C to +20 C Injector Plasma Ion Source Torch RF Generator Load Coil Ar Gas Flow Controllers Additional Gas Flow Controllers Plasma TV Vacuum System Configuration Vacuum Pumps Pump Down Time Screw-in, self-aligning No O-rings required Wide 2.5 mm internal diameter quartz as standard Optional internal diameters and injector materials are available Push-in, single piece, quartz Automatic gas connectivity Horizontal and vertical position: +/- 2 mm, 0.02 mm step width Sampling depth: 0-15 mm, 0.025 mm step width Digital, solid state RF generator, ~27 MHz Dynamic frequency matching RF power range: 0 W to 1600 W (default hot plasma power 1550 W) No plasma shield required Automated in-sample switching between hot and cold plasma Water-cooled, PFA/silver-coated, copper load coil Three channels: coolant, auxiliary, nebulizer Capacity for two further MFCs for gas dilution, oxygen addition, laser ablation etc. HD camera for remote monitoring of plasma status Three stage, differential pumping Split-flow turbo molecular pump External backing rotary pump (common to interface) < 15 min after maintenance (< 1 10-6 mbar) Interface Access Sample Cone Skimmer Cone Skimmer Inserts Interface Pump Extraction Lens Slide Valve Ion Optics RAPID Lens Electrical Connections Collision/Reaction Cell QCell Standard MFC Optional MFC Quadrupole Mass Analyzer Frequency Mass Range Scan Speed Mass Stability Abundance Sensitivity Resolution Ion Detection System Detector Minimum Dwell Time Bench height, easy access from drop down door Solid Ni, 1.1 mm diameter orifice; Pt tipped optional Ni, 0.5 mm diameter orifice; Pt tipped optional High matrix insert as standard; Robust interface option supplied; High sensitivity option available External, high performance rotary pump Single, low voltage, conical PC controlled 90 ion lens operating at a single, fixed voltage Cable free, fixed position, spring mounted gold contacts Non-consumable, zero maintenance Automatic low mass cut off Pure He collision gas Reaction gas mixtures: H 2, O 2, NH 3 /He 2 MHz 2-290 u > 3700 amu s -1 Li to U with interval masses < ± 0.025 u per day < 0.5 ppm at m-1 (m= 133 Cs) in the mass range 2-225 u User definable in the mass range 2-225 u Fixed resolution and Extended Sensitivity in the mass range 225-290 u Dual mode discrete dynode electron multiplier Simultaneous pulse/analog over four orders of magnitude for reliable cross calibration Cradle design for simplified exchange 100 μs in pulse and analog Dynamic Range > 10 orders of magnitude (<1 - > 5 10 9 cps) 5

Site requirements Environmental Range 15-35 C Temperature Rate of Change < 2 C h -1 Humidity Range 20-80% (non-condensing) Utilities Electrical Supply Power Supply temperature 200-2 V AC, 50/60 Hz single phase Apparent: 3000 VA; Effective: 2200 W 20 to 30 C, optimum at 21 C Cooling Water Argon Gas Supply Cell Gas Supply Plasma Exhaust Heat Exhaust Supply rate > 5.5 L min -1 Pressure Purity > 99.996% Typical Flow Rate 16 L min -1 Pressure Purity > 99.999% 0.25-0.6 MPa (2.5-6 bar; 36-86 psi) 0.55-0.6 MPa (5.5-6.0 bar; 82.5-90 psi) Flow rate max. 10 L min -1 Pressure Port Dimensions Flow rate (63 mm ID ducting) Port Dimensions Flow rate (63 mm ID ducting) 0.1-0.15 MPa (1-1.5 bar, 15-22.5 psi) 60.3 mm (recommended 63 mm ID ducting) 6-8 m s -1 (67-90 m 3 h-1 39.4-53.0 cfm) 60.3 mm (recommended 63 mm ID ducting) 4-6 m s -1 (45-67 m 3 h-1 26.5-39.4 cfm) Dimensions of the icap RQ ICP-MS (mm) Right View Top View Front View Left View 748 772 748 665 665 772 1020 1102 946 6

Thermo Scientific Qtegra Intelligent Scientific Data Solution (ISDS) Software With centralized control and simplified workflows, Qtegra ISDS Software delivers quality and drives productivity. The platform, common to other Thermo Scientific ICP techniques, is intuitive and easy to use for routine, highthroughput analyses, yet offers all the flexibility required for the most demanding applications. Languages supported English (default). Support for additional languages (for example Simplified Chinese and Japanese) is available through the use of specific Language Packs. Integrated control of peripherals The unique architecture in Qtegra ISDS Software allows for the control of peripheral devices via plug-ins, ensuring full implementation of all features within a single window. Regulatory compliance Qtegra ISDS Software supports Title 21 CFR Part 11 compliance. Features such as system audit trails, access control, e-signatures and secured data enable full confidence in FDA or GMP/GLP compliant environments. Supplied PC specifications Intel i5 Quad Core CPU 16 GB RAM 1 TB Hard Drive 64 bit Microsoft Windows 10 Enterprise LTSB Supported operating systems Windows 7 Professional (32 & 64 bit) Windows 10 Professional and Enterprise LTSB (32 & 64 bit) Licensing 1 instrument seat and 3 desktop seats are provided with each software license. icap RQ ICP-MS accessories Autodilution systems Automated prescriptive and intelligent dilution are the most flexible approaches for handling highly varied and complex samples. Fully inert autodilution systems provide accurate and dynamic dilution of samples and facilitate unattended operation. Qtegra ISDS Software triggers the re-analysis of high matrix or over range samples for a completely automated and hands-free workflow. Autosamplers A wide range of Teledyne CETAC Technologies and Elemental Scientific autosamplers are supported with the icap RQ ICP-MS. From small, fully-enclosed units that reduce contamination of high purity samples, to large multi-rack systems in high-throughput environmental and geochemical exploration laboratories. Argon gas dilution On-line gas dilution delivers a significant improvement in plasma robustness for the analysis of high matrix samples. Argon humidifier is included. Laser ablation Laser ablation systems are directly supported via a dedicated plug-in within the Qtegra ISDS Software. With both powerful data evaluation (trquant) and flexible data export, the icap RQ ICP-MS is a truly routine laser ablation analysis solution. Speciation Seamless integration of a range of IC, LC and GC systems for speciation analysis of elements in a variety of sample matrices and applications is delivered via the Thermo Scientific ChromControl Plug-in. The ChromControl Plug-in is powered by SII, the Thermo Scientific Chromeleon CDS Software device control interface. Comprehensive data acquisition and processing features in the tquant evaluation module simplify the identification and quantification of critical trace elemental species. Nanoparticle characterization Accurately and reliably characterize nanoparticles from single particle ICP-MS analysis utilizing the Thermo Scientific npquant Plug-in for Qtegra ISDS Software. Organics kit Organic solvents (e.g. as used in reversed phase LC applications) can be analyzed routinely with the organics kit comprising of a 1.0 mm ID quartz injector, a 50 μl min -1 PFA microflow nebulizer and organic solvent resistant waste pump tubing. Acid resistant kit For the analysis of aggressive sample matrices, for example HF or H 2 SO 4, this kit contains a PFA cyclonic spraychamber, a 2.0 mm ID sapphire injector and Pt tipped cones. 7

How does comprehensive interference removal work? With proprietary QCell technology, comprehensive single mode interference removal is achieved using pure He as a collision gas with Kinetic Energy Discrimination (KED). He KED filters out unwanted polyatomic interferences, based on difference in cross-sectional diameter of the analyte and polyatomic. Quadrupole set to filter out exact mass of target analyte. Target analyte 75 As + Save time and simplify method development by using He KED mode for the entire mass range. High transmission ensures the sensitivity and LODs needed, even on low mass analytes such as Li and Be. Rely upon predictable, reproducible interference reduction in all sample types from unique low mass cut off (LMCO). The icap RQ is the only ICP-MS that specifies elemental sensitivity in the He KED mode used in modern ICP-MS analysis. When matrix complexity demands more targeted interference removal, easily switch to reactive mode for efficient, accurate analysis. QCell flatapole dynamically applies LMCO relative to target analyte and suppresses interferences with He KED. ArCI +, Ca(OH) 2 H + Ar +, Ca +, 35 CI +, 16 O +, 1 H + Low mass cut off filters out unwanted precursor ions which are then unable to recombine later in the QCell; further reducing backgrounds than He KED alone. Complex sample matrix Mass LMCO Interferences Precursors 51 V 35 35 Cl 16 O, 37 Cl 14 N, 34 S 16 OH H, N, O, S, Cl 56 Fe 39 Ar 16 O, Ca 16 O O, Ar, Ca 63 Cu 45 Ar 23 Na, 12 C 16 O 35 Cl, 31 P 32 S C, N, O, Na, P, S, Cl, Ar 75 As 47 Ar 35 Cl, Ca 35 Cl, Ar 34 SH, 37 Cl 2 H H, S, Cl, Ca, Ar Apply low mass cut off Mass LMCO Interferences Precursors 51 V 35 35 Cl 16 O, 37 Cl 14 N, 34 S 16 OH H, N, O, S, Cl 56 Fe 39 Ar 16 O, Ca 16 O O, Ar, Ca 63 Cu 45 Ar 23 Na, 12 C 16 O 35 Cl, 31 P 32 S C, N, O, Na, P, S, Cl, Ar 75 As 47 Ar 35 Cl, Ca 35 Cl, Ar 34 SH, 37 Cl 2 H H, S, Cl, Ca, Ar Find out more at thermofisher.com/sq-icp-ms 2017 Thermo Fisher Scientific Inc. All rights reserved. ESI prepfast is used in trade by Elemental Scientific Inc. CETAC are trademarks of Teledyne Instruments Inc. Teledyne is a trademark of Teledyne Technologies Incorporated. Intel is a trademark of Intel Corporation. Microsoft, Microsoft Office and Windows are trademarks of Microsoft Corporation. All other trademarks are the property of Thermo Fisher Scientific and its subsidiaries. This information is presented as an example of the capabilities of Thermo Fisher Scientific products. It is not intended to encourage use of these products in any manner that might infringe the intellectual property rights of others. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. PS44360-EN 1217