STRUCTURAL STRAIN ESTIMATION OF SEGMENTED SHIELD TUNNEL FOR SEVERE EARTHQUAKES

Similar documents
AMPLIFICATION OF GROUND STRAIN IN IRREGULAR SURFACE LAYERS DURING STRONG GROUND MOTION

ASIAN JOURNAL OF CIVIL ENGINEERING (BUILDING AND HOUSING) VOL. 10, NO. 5 (2009) PAGES **-**

Technical Note 16 Equivalent Static Method

PLASTIC DEFORMATION CAPACITY OF H-SHAPED STEEL BEAM CONNECTED TO CONCRETE FILLED STEEL TUBULAR COLUMN

Numerical Modelling of Dynamic Earth Force Transmission to Underground Structures

D : SOLID MECHANICS. Q. 1 Q. 9 carry one mark each. Q.1 Find the force (in kn) in the member BH of the truss shown.

Centrifuge Shaking Table Tests and FEM Analyses of RC Pile Foundation and Underground Structure

Multi Linear Elastic and Plastic Link in SAP2000

Limit analysis of brick masonry shear walls with openings under later loads by rigid block modeling

THE STRUCTURAL DESIGN OF PILE FOUNDATIONS BASED ON LRFD FOR JAPANESE HIGHWAYS

A Modified Response Spectrum Analysis Procedure (MRSA) to Determine the Nonlinear Seismic Demands of Tall Buildings

Evaluation of dynamic behavior of culverts and embankments through centrifuge model tests and a numerical analysis

Mechanical Engineering Ph.D. Preliminary Qualifying Examination Solid Mechanics February 25, 2002

NORMAL STRESS. The simplest form of stress is normal stress/direct stress, which is the stress perpendicular to the surface on which it acts.

Dynamic analysis of a reinforced concrete shear wall with strain rate effect. Synopsis. Introduction

ME Final Exam. PROBLEM NO. 4 Part A (2 points max.) M (x) y. z (neutral axis) beam cross-sec+on. 20 kip ft. 0.2 ft. 10 ft. 0.1 ft.

Dynamic Analysis of a Reinforced Concrete Structure Using Plasticity and Interface Damage Models

Chapter Two: Mechanical Properties of materials

Mechanics of Materials Primer

2. Rigid bar ABC supports a weight of W = 50 kn. Bar ABC is pinned at A and supported at B by rod (1). What is the axial force in rod (1)?

ENG1001 Engineering Design 1

3. Stability of built-up members in compression

PES Institute of Technology

Sabah Shawkat Cabinet of Structural Engineering Walls carrying vertical loads should be designed as columns. Basically walls are designed in

Seismic Response Analysis of Structure Supported by Piles Subjected to Very Large Earthquake Based on 3D-FEM

Evaluation of Water Distribution Jointed Pipe Networks under Transient Ground Motions

Junya Yazawa 1 Seiya Shimada 2 and Takumi Ito 3 ABSTRACT 1. INTRODUCTION

Visit Abqconsultants.com. This program Designs and Optimises RCC Chimney and Foundation. Written and programmed

QUESTION BANK SEMESTER: III SUBJECT NAME: MECHANICS OF SOLIDS

Effect of embedment depth and stress anisotropy on expansion and contraction of cylindrical cavities

Seismic design of bridges

The Preliminary Study of the Impact of Liquefaction on Water Pipes

UNIVERSITY OF SASKATCHEWAN ME MECHANICS OF MATERIALS I FINAL EXAM DECEMBER 13, 2008 Professor A. Dolovich

Seismic Assessment of Stone Arched Bridges

Cone-shaped socket connections for cylindrical members

VORONOI APPLIED ELEMENT METHOD FOR STRUCTURAL ANALYSIS: THEORY AND APPLICATION FOR LINEAR AND NON-LINEAR MATERIALS

[5] Stress and Strain

Entrance exam Master Course

Special edition paper

ME 243. Mechanics of Solids

CHAPTER 4: BENDING OF BEAMS

SERVICEABILITY OF BEAMS AND ONE-WAY SLABS

Doctoral Dissertation 3-D Analytical Simulation of Ground Shock Wave Action on Cylindrical Underground Structures

Behaviour of Blast-Induced Damaged Zone Around Underground Excavations in Hard Rock Mass Problem statement Objectives

INTRODUCTION TO STRAIN

Section Forces Within Earth. 8 th Grade Earth & Space Science - Class Notes

Chapter 5 Elastic Strain, Deflection, and Stability 1. Elastic Stress-Strain Relationship

REPRODUCTION OF A LARGE-SCALE 1G TEST ON UNSATURATED SAND DEPOSITS AND PILE FOUNDATIONS USING CENTRIFUGE MODELING

December 10, PROBLEM NO points max.

Author(s) Sawamura, Yasuo; Kishida, Kiyoshi;

PURE BENDING. If a simply supported beam carries two point loads of 10 kn as shown in the following figure, pure bending occurs at segment BC.

Bracing for Earthquake Resistant Design

Dynamic Analysis of Burried Pipelines under Linear Viscoelastic Soil Condition

DYNAMIC ANALYSIS OF PILES IN SAND BASED ON SOIL-PILE INTERACTION

N = Shear stress / Shear strain

IZMIT BAY BRIDGE SOUTH APPROACH VIADUCT: SEISMIC DESIGN NEXT TO THE NORTH ANATOLIAN FAULT

Mechanics of Solids. Mechanics Of Solids. Suraj kr. Ray Department of Civil Engineering

SIMPLE MODEL FOR PRYING FORCES IN T-HANGER CONNECTIONS WITH SNUG TIGHTENED BOLTS

EDEXCEL NATIONAL CERTIFICATE/DIPLOMA MECHANICAL PRINCIPLES AND APPLICATIONS NQF LEVEL 3 OUTCOME 1 - LOADING SYSTEMS TUTORIAL 3 LOADED COMPONENTS

Seismic Pushover Analysis Using AASHTO Guide Specifications for LRFD Seismic Bridge Design

Mechanics of Earthquakes and Faulting

MODELING OF NONLINEAR BEHAVIOR OF RC SHEAR WALLS UNDER COMBINED AXIAL, SHEAR AND FLEXURAL LOADING

EDEXCEL NATIONAL CERTIFICATE/DIPLOMA SCIENCE FOR TECHNICIANS OUTCOME 1 - STATIC AND DYNAMIC FORCES TUTORIAL 3 STRESS AND STRAIN

CHAPTER 6: ULTIMATE LIMIT STATE

Effective stress analysis of pile foundations in liquefiable soil

The University of Melbourne Engineering Mechanics

Members Subjected to Torsional Loads

FRICTION SLIPPING BEHAVIOR BETWEEN CONCRETE AND STEEL -AIMING THE DEVELOPMENT OF BOLTED FRICTION- SLIPPING JOINT -

PDDC 1 st Semester Civil Engineering Department Assignments of Mechanics of Solids [ ] Introduction, Fundamentals of Statics

A METHOD OF LOAD INCREMENTS FOR THE DETERMINATION OF SECOND-ORDER LIMIT LOAD AND COLLAPSE SAFETY OF REINFORCED CONCRETE FRAMED STRUCTURES

SHAKING TABLE TEST OF STEEL FRAME STRUCTURES SUBJECTED TO NEAR-FAULT GROUND MOTIONS

Seismic analysis of horseshoe tunnels under dynamic loads due to earthquakes

Model tests and FE-modelling of dynamic soil-structure interaction

Basic Energy Principles in Stiffness Analysis

Name :. Roll No. :... Invigilator s Signature :.. CS/B.TECH (CE-NEW)/SEM-3/CE-301/ SOLID MECHANICS

five Mechanics of Materials 1 ARCHITECTURAL STRUCTURES: FORM, BEHAVIOR, AND DESIGN DR. ANNE NICHOLS SUMMER 2017 lecture

1 Introduction. Abstract

Discrete Element Modelling of a Reinforced Concrete Structure

QUESTION BANK DEPARTMENT: CIVIL SEMESTER: III SUBJECT CODE: CE2201 SUBJECT NAME: MECHANICS OF SOLIDS UNIT 1- STRESS AND STRAIN PART A

PERIYAR CENTENARY POLYTECHNIC COLLEGE PERIYAR NAGAR - VALLAM THANJAVUR. DEPARTMENT OF MECHANICAL ENGINEERING QUESTION BANK

Using the Timoshenko Beam Bond Model: Example Problem

COMPARISON BETWEEN 2D AND 3D ANALYSES OF SEISMIC STABILITY OF DETACHED BLOCKS IN AN ARCH DAM

BE Semester- I ( ) Question Bank (MECHANICS OF SOLIDS)

Determine the resultant internal loadings acting on the cross section at C of the beam shown in Fig. 1 4a.

Solution: T, A1, A2, A3, L1, L2, L3, E1, E2, E3, P are known Five equations in five unknowns, F1, F2, F3, ua and va

Vertical acceleration and torsional effects on the dynamic stability and design of C-bent columns

PLATE GIRDERS II. Load. Web plate Welds A Longitudinal elevation. Fig. 1 A typical Plate Girder

STATICALLY INDETERMINATE STRUCTURES

Dynamic Response of EPS Blocks /soil Sandwiched Wall/embankment

Lecture 15 Strain and stress in beams

DETERMINING THE STRESS PATTERN IN THE HH RAILROAD TIES DUE TO DYNAMIC LOADS 1

Materials: engineering, science, processing and design, 2nd edition Copyright (c)2010 Michael Ashby, Hugh Shercliff, David Cebon.

STRESS. Bar. ! Stress. ! Average Normal Stress in an Axially Loaded. ! Average Shear Stress. ! Allowable Stress. ! Design of Simple Connections

Study of Pile Interval of Landslide Restraint Piles by Centrifuge Test and FEM Analysis

Hyperbolic Soil Bearing Capacity

Downloaded from Downloaded from / 1

CHAPTER 3 THE EFFECTS OF FORCES ON MATERIALS

Samantha Ramirez, MSE. Stress. The intensity of the internal force acting on a specific plane (area) passing through a point. F 2

A CONNECTION ELEMENT FOR MODELLING END-PLATE CONNECTIONS IN FIRE

CHAPTER 5. Beam Theory

Transcription:

STRUCTURA STRAIN ESTIMATION OF SEGMENTED SHIED TUNNE FOR SEVERE EARTHQUAKES 09 T KOIKE SUMMARY In order to realistically assess the seismic risk of a shield tunnel, the accurate estimate of the structural strains which depends upon the structural details, segment materials, properties of the surrounding soil, the nature of the propagating wave and so on is critical. Emphasis in this study, therefore, has been placed on the analysis of structural strains for segmented shield tunnel under severe earthquake ground motions. The purpose of this study is () to define the slippage factor in order to estimate the decrease in tunnel strain resulting from the slippage effect, () to furnish the calculation formula for the structural strains of the shield tunnel, and (3) to describe the most effective use of seismic isolation layer for the shield tunnel which is comparable to slippage effect. INTRODUCTION Segmented shield tunnels were cracked at the concrete lining wall, but were not damaged at the joints in the axial direction in the 995 Hyogoken-Nanbu Earthquake. Based on the current design method which was established on the basis of allowable stress criterion, however, all the joints of the shield tunnel in the axial direction could not be designed without the expansion joints for severe ground motion which is given as the level ground motion to be established in Japan since 995. This great discrepancy between the non-damage observations of actual joints and the design requirement of expansion joints for stress release result from the stress based design, although the underground structure should be designed and thus based on the structural strains against externally forced ground displacements. In order to realistically assess the seismic risk of a shield tunnel, the accurate estimate of the structural strains which depends upon the structural details, segment materials, properties of the surrounding soil, the nature of the propagating wave and so on is critical. Emphasis in this study, therefore, has been placed on the analysis of structural strains for segmented shield tunnel under severe earthquake ground motions. Noting that the shear stress at the interface between the tunnel and the soil makes a large elongation of the tunnel enough to cause the joint failure, the most effective approach is to find some methods how to reduce the shear stress. One approach is to take into consideration the slippage mechanism between the tunnel and the soil, while the other is to introduce the seismic isolation layer between them. The purpose of this study is () to define the slippage factor in order to estimate the decrease in tunnel strain resulting from the slippage effect, () to furnish the calculation formula for the structural strains of the shield tunnel, and (3) to describe the most effective use of seismic isolation layer for the shield tunnel which is comparable to slippage effect. Kawasaki Steel Co.,35 Naganuma-cho,Inage-ku, Chiba, Japan, koike@kawasaki-steel.co.jp

. STRUCTURA MODES OF SHIED TUNNE. Structural Model Shield tunnel is composed of many segments which are fasten with bolts. Some segments are made of concrete and the others are of steel elements as shown in Fig. enforcing plate rib pouring hole lift hole air release Kawashima ) describes the characteristics of structural behaviours of shield tunnel, where the tunnel deformations are different in compression mode and tensile mode as shown in Fig.. This difference also makes the neutral axis deviate to the compression side in bending mode. Segment joint plate Ring joint Fig. Segment of shield tunnel. main plate N N N N M M ()compression mode ()tension mode (3)bending mode Fig. Displacement modes of shield tunnel ) Based on this consideration, the cross-sectional area and bending rigidity of shield tunnel are estimated in the equivalent form with Young s modulus. Two different cross-sectional areas are defined in the following way 4) for compression and tension modes, respectively. C = EsA s, T = + EsA s lskj in which A s : cross-sectional area of a segment ring E s : Young s modulus of a segment l s : width of a segment K J : spring modulus of one ring joint K J = k J n k J : spring modulus of a joint n : number of joints per one ring joint EsA s EI eq = cos 3 φ cosφ + π + φ sinφ E si s I s : cross-sectional moment of a segment ring r: radius of a tunnel with φ = sin - d r d: length from the tunnel center to the cross-sectional center Consider a seismic wave horizontally travelling and incident to the tunnel with an angle φ. The apparent ground strain at the tunnel location is given by ε G = π Uhχ ν φ a where a is the apparent wave length along the tunnel axis, while χ ν φ is the directional parameter given for Rayleigh type surface wave (ν=r) and ove type surface wave (ν=). Both parameters are given as follows. a = cosφ, χ R φ = cosφ, χ φ = - sinφ () () (3) 09

The seismic deformation method 4) provides the structural strains of the tunnel which can be calculated with the apparent ground strain and the conversion factors to be defined hereunder for tension and compression modes, respectively. ε SA = α A ε G, ε SB = α B ε G π D a in which (4) α A = + π λ A a, α B = + π λ B a 4 with 4 λ A = K A, λ B = K B EI eq (5) where K A and K B are spring modulus for axial and transverse directions. 3. Shear Stress Acting on the Tunnel Surface 3.STRUCTURA STRAIN IN SIPPAGE When the earthquake intensity is severe and the free field strain reaches the order of magnitude of 0-3 to 0 -, the chance of a slip taking place between the tunnel and the surrounding soil significantly increases causing large strain concentrations at various joints and connections in the shield tunnel system. The simplified mechanism of slip assumed in this study is that the slip initiate when the shear stress exceeds the critical value of cr = c + σ tanφ where c= cohesion stress, σ = normal stress at the interface between the tunnel and the soil and φ = angle of friction between the tunnel and the soil. Therefore, the critical shear stress increases as the depth of soil cover increases. The possible upper limit of normal stress is controlled by the shadow zone in Fig.3, the normal soil stress of which is effectively acting to the tunnel surface as shown in Fig.4. The above discussion suggests that the critical shear stress behaves not linearly but at least bi-linearly as expressed in Fig.5. If the ground condition installing the shield tunnel can expect a sufficient lateral force, the height of the effective soil pressure zone in Fig.3 is less than several times of the tunnel diameter, so that the possible height of soil cover to the tunnel is approximately 5 ~ 0 meters. According to the Japan Gas Association (JGA), the critical shear stress is recommended to use the value of 0.0N/mm for the gas pipeline which is often installed under the soil cover of. ~.5 m. Based on these data, the critical shear stress of the shield tunnel installed in several 0 m depth should increase up to 0.05 ~ 0. N/mm in proportional to the effective soil depth of 5 ~ 0 m. The value of 0.05 ~ 0. N/mm is assumed for numerical purposes as the critical shear stress in this study. Ground Surface U h Effective soil pressure zone Shield Tunnel Fig.3 Vertical soil pressure acting on the tunnel. cr Fig.4 Shear stress acting on the tunnel surface caused by free field motion. Fig.5 Shear stress and strain relationship of the soil. γ 3 09

3. Formulation The free body diagram of a tunnel segment x shown in Fig.6 is subjected to an acceleration u/. Applying D Alembert s principle to the surface, internal and inertia forces acting on this segment, one obtains σ u A σ + x πd x G x σ ρa x UVW + = + (6) RST Using this formulae, the average shear stress acting on the tunnel surface can be deduced as σ u ρa x D σ + σ G = (7) π D π αa εg a Slippage along the interface between the tunnel and the surrounding soil can only take place when the earthquake intensity is large enough that the shear stress produced in the interface reaches the critical value. Noting that G is the maximum shear stress in the soil at the interface, the following criteria can be used to determine whether the slippage will or will not take place at least in some portion along the interface. If If G cr G cr, slippage will not take place., slippage will take place. t x Fig.6 Equilibrium of tunnel element. G cr γ γ cr This situation can be expressed with the equation for equilibrium in the partial slippage given by a f u u ρa EA = π eq D x where u s is the tunnel displacement and πd (8) ;for nonslippage area (9) ;for slippage area Fig.8 Shear stress distribution along the tunnel axis. in which u cr is the critical relative displacement initiating the slippage defined by u cr =πd cr /K A. Fig.7 shows the schematic profile of the shear strain distribution along the tunnel axis. When the sinusoidal wave form is assumed for the free field motion as u G (η)=u h sinη, the solution of eq.(8) for the non-slippage region in the partial slippage provides the tunnel displacement as a f = R S T b K u u K u A G s R S T A cr g a f F b crghg κ sinh κη us η = Uh sinh + + κ sinh κη sinh κη + κ and that of eq.(8) for the slippage region furnishes the tunnel displacement as b cr g cr u U cr h IU KJ V W Fig.7 Shear stress-strain relationship of the soil. G with κ = a (0) π λ A x u S η = κ u cr - η + ηπ + C () Eliminating C at the location of η=η cr, one can obtain the critical relative displacement ratio S expressed with a parameter η cr to be identical to the location of slippage initiation. S = ucr Uh = + κ κ cosη cr tanh κη cr + sinη cr κ π - η cr tanh κη cr + () 4 09

The maximum tunnel strain when the partial slippage is taking place can be calculated by ε s us = x π us = cos φ η η= 0 a η= 0 (3) Substituting eqs.(0) and () into eq.(3), the maximum tunnel strain in the partial slippage is expressed by ε S = qsα A ε G with q s = - S + κ - sinη cr κ sinh κη cr (4) and the relative displacement between the soil and the tunnel motion is provided by = - with qs * α A ug qs * = + κ sinηcr - S - π 8 + ηcr - π ηcr κ (5) in which G * = - α Aq s (6) cr S The slippage factors, q s and q * s, are dependent on the conversion factor a. Those results suggest that the pipe A strain distribution in slippage deviates from the sinusoidal wave form. The simplified approximate formula for q s and q * s is also developed by the author who assumed the shape of structural strain distribution under slippage to be sinusoidal in the following way. G cr, q = - cosξ + π - ξ sinξ, ξ = arcsin cr G ; G cr q = G cr, q * = + π 8 - ξ sinξ - ξ cosξ ; G cr q * = Fig.9 shows the slippage factors for the shear stress normalized by the critical shear stress, in which the simplified approximate formula (broken line) expresses an average value around the numerical results of rigorous analyses. These trends are applicable for both slippage factors. Once the tunnel strains are obtained, various forces acting on a tunnel segment are given in Table. Slippage factor q s 0. 0.0 0 00 G / cr Conversion factor α A 0. 0. 0.4 0.6 0.8 0.9 0.99 0.999 Appro. (7) (8) Table Formula to obtain forces from tunnel strains. Slippage factor q*s Forces Tensile force Comprssive force 0. Bending moment Shear force Formula P T = T T ε SA P C = C C ε SA M = F H I K a f ε D EI eq SB Q = π a D EI eqε SB 0.0 0 00 / G cr ()Slippage factor for tunnel strain ()Slippage factor for relative displacement Fig.9 Slippage factors 5 09

4. SEISMIC ISOATION AYER FOR SHIED TUNNE 4. Formulation When a seismic isolation layer is installed between the tunnel and the surrounding soil, the ground displacement has two components of shear deformation which are contributed from surrounding soil and seismic isolation layer shown in Fig.0. The combined soil stiffness K * A is evaluated as the series system of the stiffness K A of surrounding soil and the stiffness K B of seismic isolation layer in the following way. KA * = KAKB KA + KB (9) Since the equation for equilibrium discussed in Section 3. is valid for the tunnel element in this section, the following equation is applied for the tunnel element having a seismic isolation layer. K A K * A x x Sourrounding soil Seismic isolation layer Seismic isolation layer W Surface ground Fig.0 Ground displacement combined with surrounding soil and seismic isolation layer. u ρa π D = aeaf s eq R S T s u x = πd K A u G - u S ; 0 x a 4 - W K * A u G - u S ; a 4 - W x a (0) ξ W A W Fig. Structural model of shield tunnel and seismic isolation layer. () Fig. Shear stress distribution. x in which W is the length of a seismic isolation layer. Fig. shows the schematic profile of the tunnel and seismic isolation layer installed at the interface between the tunnel and the surrounding soil. Solving the eq.(0), one obtains the following general solutions. us ξ = α A ugsinξ + Ssinh λ A ξ kcosφ + Tcosh λ A ξ kcosφ in which φ is incident angle to the tunnel, and * us ξ = α * A ugsinξ + S * sinh λ A * ξ kcosφ + T * cosh λ A * ξ kcosφ () αa = / + kcosφ λa, αa * = / + kcosφ λa *, λa = KA, λa * = KA *, k = π (3) The boundary condition requires the continuity of displacement and bending angle at the point A in Fig., while the seismic wave given by a sinusoidal wave form must satisfy the wave conditions at x=0 and x=π/. O N O Q us us a W us u s bξwg= usbξwg = at ξ W and u saf NM ξqp * * *, ξ ξ ξ ξ M = 0 = 0, P ξ ξ M = 0 4 Pξ π = W = W = Then the maximum axial strain of the shield tunnel can be obtained as the summation of ground shaking part and strain reduction part due to seismic isolation layer in the following way. N O Q (4) 6 09

ε m = α A ε G + λ A S (5) in which the parameters S and S * can be evaluated from the following equations. sinhζ ζ ξ W coshζ,, - sinhζ * + coshζ * tanh ζ * π ξ W - ζ * coshζ * - sinhζ * ξ W tanh ζ * π ξ W S S * = αa * - αa ugsinξw αa * - αa ugcosξw (6) where ζ = λa kcosφ ξw, ζ * * λa = kcosφ ξw, ξw = k 4 - W cosφ - ω t (7) 4.Numerical Study The shield tunnel is composed of steel segments with.75m in diameter and.8 cm in thickness (which is equal to the equivalent cross-sectional stiffness (EA) eq =3.36x0 7 KN). The values of 0.0, 0.05 and 0. N/mm is used as the parameter for critical shear stress in slippage, while the values, ζ W, of 0. and 0. is adopted as the ratio of the width of seismic isolation layer per seismic wave length. The values, ζ G, of 0.00, 0.0 and 0. are also selected as the ratio of reduced soil stiffness of seismic isolation layer per original soil stiffness. Basic parameters of seismic wave length, soil stiffness and response spectrum at baserock are assumed only for the numerical purposes in this study to be identical to those of the guideline of seismic design method of Japan Water Works Association (JWWA) 5). For instance, the level ground motion in JWWA is estimated with the response spectrum of seismic velocity at the baserock as shown in Fig.3. Fig.4 (), () and (3) show the relationship between the structural strains and typical period of the ground for various stiffness and width of seismic isolation layer and for various critical shear stresses in slippage. The symbols, ε G, ε ns, ε s, ε m, are apparent ground strain given by eq.(), structural strains given by eq.(4) in nonslippage (q=) and in slippage, and axial strain in seismic isolation layer given by eq.(5), respectively. The following results can be summarised. Fig.4 () shows that the extremely degraded soil stiffness used for seismic isolation layer is not always effective for the reduction of shear stress acting between the tunnel and the surrounding soil. Fig.4 () shows that for the surrounding soil of the critical shear stress less than 0.N/mm, slippage effect is more remarkable in longer typical period than the reduction effect due to seismic isolation layer; and Fig.4(3) shows that the reduction effect due to seismic isolation layer is comparatively effective in shorter typical period for the width of layer longer than 0% of the seismic wave length. These results suggest that the seismic isolation layer method is effective for the ground with comparatively short period, while the method taking the slippage effect is more activated in the longer period of the ground. Response spectrum of seismic velocity (kine) 000 00 0 0. 0 Typical period (sec) Fig.3 Response spectrum of seismic velocity given by JWWA. 7 09

.0E-0.0E- 0.0E-03.0E- 03 Axial strain.0e-04.0e-05.0e-06 0. 0 Typical Period of Ground ()Various soil stiffness ε G ε ns ε s, cr =0.05N/ mm ƒã m CƒÄ G =0.00 ƒã m CƒÄ G =0.0 ƒã m CƒÄ G =0. (sec) Axial strain.0e- 04.0E- 05.0E- 06 0. 0 Typical Period of Ground ()Various critical shear stress ƒã G ƒã ns ƒã m ƒã s,ƒñ cr =0. 0N/ mm ƒã s,ƒñ cr =0. 05N/ mm ƒã s,ƒñ cr =0.N/ mm (sec).0e- 0.0E- 03 Axial strain.0e- 04.0E- 05 ƒã m CƒÄ W =0..0E- 06 0. 0 (3)Various width Fig.4 Comparison between slippage effect and stress reduction effect of seismic isolation layer. 5.CONCUSIONS In order to estimate the axial strains of shield tunnel, both slippage and seismic isolation mechanism are taken into consideration for severe earthquake (which is called evel ground motion in Japan). Based on he simplified design formula developed herein, several numerical results are furnished and summarised as follows. ) for the surrounding soil of the critical shear stress less than 0.N/mm, slippage effect is more remarkable in longer typical period than the reduction effect due to seismic isolation layer; )the reduction effect due to seismic isolation layer is comparatively effective in shorter typical period for the width of layer longer than 0% of the seismic wave length; and 3)the extremely degraded soil stiffness used for seismic isolation layer is not always effective for the reduction of shear stress acting between the tunnel and the surrounding soil. REFERENCES )Kawashima, K.[994]:Seismic Design of Underground Structures, Kashima Publishing Inc. )Koike, T. and T.Imai[998]: Structural displacement analysis of buried pipelines against strong earthquake ground motions, Structure and Earthquake Engineering, JSCE, pp.647-658. 3)Koike, T.[983]: Estimation of buried pipe strains under seismic risk, JSCE, Vol.33, No.3, pp.3-4. 4)Kawashima, K.[985]: Seismic resistant design procedure of shield tunnels (Part ) Application of seismic deformation method based on equivalent stiffness of shield segments, Report of Public Works Research Institute, Ministry of Construction,No.6. 5)JWWA[997]: Guideline of Seismic Design Method of Water Works Facilities, Japan Water Works Association. ƒã G Typical Period of Ground ƒã ns ƒã s CƒÑ cr =0.05N/ mm ƒã m CƒÄ W =0. (sec) 8 09