Computational Fluid Dynamics Based Analysis of Angled Rib Roughened Solar Air Heater Duct

Similar documents
INTERNATIONAL JOURNAL OF SCIENTIFIC & TECHNOLOGY RESEARCH VOLUME 5, ISSUE 09, SEPTEMBER 2016 ISSN

IJSRD - International Journal for Scientific Research & Development Vol. 3, Issue 06, 2015 ISSN (online):

COMPUTATIONAL FLUID DYNAMICS ANALYSIS OF A V-RIB WITH GAP ROUGHENED SOLAR AIR HEATER

A Computational Fluid Dynamics Investigation of Solar Air Heater Duct Provided with Inclined Circular Ribs as Artificial Roughness

EFFECT OF STAGGERED RIB LENGTH ON PERFORMANCE OF SOLAR AIR HEATER USING V-RIB WITH SYMMETRICAL GAP AND STAGGERED RIB

Thermo-Hydraulic Performance of a Roughened Square Duct Having Inclined Ribs with a Gap on Two Opposite Walls

Augmented Heat Transfer in Square ducts with Transverse and Inclined Ribs with and without a gap

International Journal of Scientific & Engineering Research, Volume 6, Issue 5, May ISSN

International Journal of Advanced Engineering Technology E-ISSN

CFD analysis of solar air heater having absorber plate roughened with compound turbulators

Effect of roughness shape on heat transfer and flow friction characteristics of solar air heater with roughened absorber plate

Thermo Hydraulic Performance of Solar Air Heater by Using Double Inclined Discrete Rib Roughened Absorber Plate

Exergy Analysis of Solar Air Collector Having W Shaped Artificial Roughness

ARTICLE IN PRESS. K.R. Aharwal a,, B.K. Gandhi b, J.S. Saini b

W-Discrete Rib for Enhancing the Thermal Performance of Solar Air Heater

A CFD Analysis Of A Solar Air Heater Having Triangular Rib Roughness On The Absorber Plate

Heat transfer and fluid flow analysis of roughness ribin solar air heater duct by computational fluid dynamics (CFD)

CFD Analysis of Heat Transfer through Artificially Roughened Solar Duct

Numerical Investigation of Heat Transfer and Fluid Flow Characteristics of Roughened Solar Air Heater Duct

Performance Investigation of Artificially Roughened Duct used in Solar Air Heaters

CFD Analysis for Thermal Behavior of Turbulent Channel Flow of Different Geometry of Bottom Plate

Comparative study of Different Geometry of Ribs for roughness on absorber plate of Solar Air Heater -A Review

Numerical and Experimental Investigation of Heat Transfer Using Discrete Ribs

Numerical Investigation of Heat Transfer and Fluid Flow Characteristics of Square Type Tabulator Roughness Solar Air Heater

CFD based flow and heat transfer analysis of various ribs in solar air heater duct by continuous ribs on absorber plate

Performance Of Solar Air Heaters With Corrugated Absorber Plate- A CFD Approach

Experimental Heat transfer study of Turbulent Square duct flow through V type turbulators

HEAT TRANSFER AND FRICTION FACTOR CHARACTERISTICS OF COMPOUND TURBULATORS IN RECTANGULAR DUCTS OF SOLAR AIR HEATER

Department of Mechanical Engineering, M.A.C.T. (R.E.C.), Bhopal , India b. Received 15 December 2000; accepted 15 January 2001

Numerical Investigation on Turbulent Forced Convection in Heating Channel Inserted with Discrete V-Shaped Baffles

UNCORRECTED PROOF ARTICLE IN PRESS

Correlations for Double Flow Double Pass SAH with Smooth Absorber Plate

Performance evaluations of two pass solar air heater using 60⁰ inclinedvshaped ribs on absorber plate

EFFECT OF DIFFERENT PARAMETERS ON THE PERFORMANCE OF RIB ROUGHNESS SOLAR DUCT

EFFECT OF BAFFLES GEOMETRY ON HEAT TRANSFER ENHANCEMENT INSIDE CORRUGATED DUCT

Heat Transfer Enhancement of Solar Air Heater By Using Artificial Roughness double inclined ribs

Review of Roughness Enhancement of Solar Air Heaters having Different Rib Roughness Geometries on Absorber Plate

"Experimental investigation of heat transfer enhancement by u-shaped Turbulator"

Experimental Validation of Heat Transfer Enhancement in plate Heat Exchanger with Non Conventional Shapes of Rib

Exergetic Performance Evaluation and Comparative Study of A Roughened Solar Air Heater using MATLAB

NUMERICAL SIMULATION ON RECTANGULAR CONVERGENT AND DIVERGENT RIBBED CHANNELS

Theoretical prediction of performance of Single and Double pass solar air heaters with artificial roughened absorber plates

Effect of rib height on heat transfer and friction factor in a square channel roughened by inclined ribs with a gap

Laminar Forced Convection and Heat Transfer Characteristics in a Square Channel Equipped with V-Wavy Surface

Numerical Study of the Three-dimensional Flow in a Flat Plate Solar Collector with Baffles

WALL ROUGHNESS EFFECTS ON SHOCK BOUNDARY LAYER INTERACTION FLOWS

Comparative Analysis of Heat Transfer and Friction Characteristics in a Corrugated Tube

Numerical Heat Transfer Study of Turbulent Square Duct Flow through W-Type Turbulators

International Journal of Engineering, Business and Enterprise Applications (IJEBEA)

TURBULENCE AND PRESSURE DROP BEHAVIORS AROUND SEMICIRCULAR RIBS IN A RECTANGULAR CHANNEL

Global Journal of Engineering Science and Research Management

Experimental investigation of heat transfer augmentation in triangular duct with rectangular wing

FLOW AND HEAT TRANSFER ANALYSIS OF VARIOUS RIBS FOR FORCED CONVECTION HEAT TRANSFER

ENHANCEMENT OF HEAT TRANSFER FOR AIR FLOW THROUGH A DUCT WITH VARIOUS RIBS

3D Numerical Study on Laminar Forced Convection in V-Baffled Square Channel

Empirical study of heat transfer at input area of turbojet blades

NUMERICAL HEAT TRANSFER ENHANCEMENT IN SQUARE DUCT WITH INTERNAL RIB

Numerical Study on Heat Transfer Enhancement in a Rectangular Duct with V-Shaped Ribs

EXPERIMENTAL STUDY OF HEAT TRANSFER AND PRESSURE LOSS IN CHANNELS WITH MINIATURE V RIB-DIMPLE HYBRID STRUCTURE

CFD Analysis of Forced Convection Flow and Heat Transfer in Semi-Circular Cross-Sectioned Micro-Channel

Numerical Investigation of Multijet Air Impingement on Pin Fin Heat Sink with Effusion Slots

Cfd Simulation and Experimentalverification of Air Flow through Heated Pipe

CFD Analysis & Experimental Investigation to improve Heat Transfer Enhancement in flat plate with W Ribs

Outlines. simple relations of fluid dynamics Boundary layer analysis. Important for basic understanding of convection heat transfer

COMPUTATIONAL FLUID DYNAMICS ANALYSIS ON HEAT TRANSFER AND FRICTION FACTOR CHARACTERISTICS OF A TURBULENT FLOW FOR INTERNALLY GROOVED TUBES

Chapter 3 NATURAL CONVECTION

Empirical assessment of heat transmission and pressure loss in turbojet blades

INTERNATIONAL JOURNAL OF ENGINEERING SCIENCES & RESEARCH TECHNOLOGY

Convective Heat Transfer and Thermal Performance in a Circular Tube Heat Exchanger Inserted with U-Shaped Baffle

Heat Transfer Enhancement in Turbines using Dimples- A CFD Study Nitish Kumar Jain 1 Dr.U.S. Mallikarjun 2

Investigation of Jet Impingement on Flat Plate Using Triangular and Trapezoid Vortex Generators

Second law optimization of a solar air heater having chamfered rib groove roughness on absorber plate

ENERGY PERFORMANCE IMPROVEMENT, FLOW BEHAVIOR AND HEAT TRANSFER INVESTIGATION IN A CIRCULAR TUBE WITH V-DOWNSTREAM DISCRETE BAFFLES

CFD Analysis on Flow Through Plate Fin Heat Exchangers with Perforations

Numerical and Experimental Study on the Effect of Guide Vane Insertion on the Flow Characteristics in a 90º Rectangular Elbow

Fluid Flow and Heat Transfer Characteristics in Helical Tubes Cooperating with Spiral Corrugation

Conjugate heat transfer from an electronic module package cooled by air in a rectangular duct

Numerical Analysis of Tube-Fin Heat Exchanger using Fluent

Numerical Analysis of a Helical Coiled Heat Exchanger using CFD

Analysis of Heat Transfer in Pipe with Twisted Tape Inserts

Experimental Study of Fluid Flow and Heat Transfer Characteristics of Rough Surface, Impinged by a Confined Laminar Slot Air Jet

Heat Augmentation Using Non-metallic Flow Divider Type Inserts in Forced Convection

Flow and Heat Transfer Profiles in a Square Channel with 45 V-Downstream Orifices

Numerical analysis of fluid flow and heat transfer in 2D sinusoidal wavy channel

Comparative study of the e ects of two types of ribs on thermal performance of solar air heaters

DESIGN & COMPUTATIONAL FLUID DYNAMICS ANALYSES OF AN AXISYMMETRIC NOZZLE AT TRANSONIC FREE STREAM CONDITIONS

HEAT TRANSFER AND FLOW CHARACTERISTICS OF A BACKWARD-FACING STEP FLOW WITH MIST

IJTRD Mar Apr 2019 Available 1

EXPERIMENTAL AND CFD ANALYSIS OF TURBULENT FLOW HEAT TRANSFER IN TUBULAR HEAT EXCHANGER

EXPERIMENTAL AND CFD ANALYSIS OF TURBULENT FLOW HEAT TRANSFER IN TUBULAR EXCHANGER

Investigation of Heat Transfer on Smooth and Enhanced Tube in Heat Exchanger

CHAPTER 7 NUMERICAL MODELLING OF A SPIRAL HEAT EXCHANGER USING CFD TECHNIQUE

Numerical simulation of fluid flow in a monolithic exchanger related to high temperature and high pressure operating conditions

Experimental Analysis of Heat Transfer Enhancement over Dimpled Surface on One Side of Plate

Heat transfer characteristics in forced convection through a rectangular channel with 60 tilted staggered ribs

Effect of radius ratio on pressure drop across a 90 bend for high concentration coal ash slurries

Keywords: Spiral plate heat exchanger, Heat transfer, Nusselt number

HEAT TRANSFER ENHANCEMENT WITH ELLIPTICAL TUBE UNDER TURBULENT FLOW TiO 2 -WATER NANOFLUID

Comparison Of Square-hole And Round-hole Film Cooling: A Computational Study

DESIGN AND CFD ANALYSIS OF A CENTRIFUGAL PUMP

Transcription:

Research Article International Journal of Thermal Technologies ISSN 2277-4114 2013 INPRESSCO. All Rights Reserved. Available at http://inpressco.com/category/ijtt Computational Fluid Dynamics Based Analysis of Angled Rib Roughened Solar Air Heater Duct Anil Kumar a, Muneesh Sethi a, Khushmeet Kumar a*, Sourabh Khurana a and Abhilash Pathania a a Mechanical Engineering Department, Shoolini University, Solan, (India)-173212 Accepted 24 April 2013, Available online 15June 2013, Vol.3, No.2 (June 2013) Abstract An artificial roughness on the heat transfer surface in the form of projections mainly creates turbulence near the wall or breaks the laminar sub-layer and thus enhances the heat transfer coefficient. In the present work the performance of a solar air heater duct provided with artificial roughness in the form of thin circular wire in discrete angled rib geometries has been analyzed using Computational Fluid Dynamics (CFD). The effect of this geometry on heat transfer and friction factor and performance enhancement was investigated covering the range of roughness parameters, P/e=8, e/d=0.043, d/w=0.25, g/e=1.0, α=60 and working parameters (Reynolds number, Re from 2,000 to 20,000). Different turbulent models have been used for the analysis heat transfer and friction factor and their results are compared with Dittus - Boelter Empirical relationship for smooth surface. Renormalization k-epsilon model based results have been found in good agreement and accordingly this model is used to predict heat transfer and friction factor in the duct. Keywords: CFD, Solar Air Heater Duct 1. Introduction 1 Thermal efficiency of solar air heater is significantly low because of low convective heat transfer coefficient between the absorber plate and air, leading to high absorber plate temperature and greater amount of heat losses to the ambient. It has been found that the main thermal resistance to the convective heat transfer is due to the formation of boundary layer on the heat transferring surface. Efforts for enhancing heat transfer have been directed towards artificially destroying or disturbing this boundary layer. The application of artificial roughness in the form of repeated ribs on the heat transfer surface has been recommended to enhance the heat transfer coefficient by several investigators. Early studies on transverse rib roughness by Prasad and Saini discussed the effect of relative roughness height (e/d) and relative roughness pitch (P/e) on Nusselt number and friction factor. The maximum enhancement in Nusselt number and friction factor were found to be 2.38 and 4.25 times respectively in comparison to that for smooth duct. Gupta et al investigated the effect of relative roughness height, angle of attack and Reynolds number on Nusselt number and friction factor in rectangular duct having inclined circular wire ribs on the absorber plate. Cho et al investigated the characteristics of square duct roughened on two opposite sides with inclined rib having small gap equal to rib height. The heat transfer coefficient is reported * Corresponding author: Khushmeet Kumar to be higher due to gap in the inclined rib which is thought to accelerate and energize the retarded boundary layer flow. The gap provided on the downstream side of inclined rib resulted in higher enhancement in heat transfer than that on the upstream side of the inclined rib. Aharwal et al experimentally studied the effect of width and position of gap in an inclined ribs having square crosssection on heat transfer and friction characteristics of a rectangular duct and reported that the inclined rib with gap arrangement shows higher enhancement in heat transfer compared to that of the continuous inclined rib arrangement. The literature review shows that the use of artificial roughness in different forms and shapes is an effective means of improving the performance of rectangular ducts. Numbers of experimental investigations involving roughness elements of different shapes, sizes and orientations with respect to flow direction have been carried out in order to obtain an optimum arrangement of roughness element geometry. It was found that a transverse rib roughness enhances the heat transfer coefficient by flow separation and generation of vortices on the upstream and downstream of rib and reattachment of flow in the inter-rib spaces. Angling of transverse rib further enhances the heat transfer on account of the movement of vortices along the rib and formation of a secondary flow cell which results in high heat flow region near the leading end. In the present work, CFD based study on the performance of rectangular duct, having the absorber plate 43

Figure.1 Schematic diagram of experimental set up with artificial roughness in the form of discrete angled ribs has been carried out. 2. Details of Experimental set-up A schematic diagram of experimental setup is shown in Fig.1. It consists of an entry section, test section, exit section, transition section, a flow measuring orifice-meter and a centrifugal blower with a control valve. The wooden rectangular duct having a size of 2400 mm 300mm 25mm and is provided with an entrance section, a test section and an exit section of lengths 525mm, 1000mm and 875mm, respectively, including the length of plenum on the exit side in order to minimize the end effects on the test section as per the recommendations of ASHRAE Standard 93-97. 3. Details of roughness parameters for CFD analysis The relative gap position (d/w) and relative gap width (g/e) values are selected as 0.25 and 1.0 based on the optimum value of these parameter reported in the literature. Selected other parameters such as, relative roughness pitch (P/e) values is selected as 8, relative roughness height (e/d) values is selected as 0.043 and angle of attack (α) value is selected as 60, based on the optimum values of theses parameters reported in the literature. Table.1 shows in the values of flow and roughness parameters for this study. Table.1: Range of parameters Sr. No. 1 Parameters Relative roughness gap postion (d/w) Values 2 Relative roughness pitch(p/e) 8 3 Relative roughness height (e/d) 0.043 4 Angle of attack(α) 60 5 Duct aspect ratio (W/H) 12 6 Reynolds number(re) 2000-20000 7 Relative gap width (g/e) 1 4. Computational fluid dynamics (CFD) Computational fluid dynamics is analysis of the system involving fluid flow heat transfer and associated phenomena such as chemical reaction by means computer based simulation. In this investigation a three dimensional numerical simulation of the conjugate heat transfer and fluid flow was conducted using the CFD code FLUENT 6.3.26. The modeling was carried out in order to predict and explain the experimental observations. 6 44

Nusselt number,nu Anil Kumar et al International Journal of Thermal Technologies, Vol.3, No.2 (June 2013) 4.1 Modeling in GAMBIT 4.1.1 Geometry and grid arrangement The solution domains used for CFD analysis has been generated as shown Fig.2. The arrangement of domain solution in the form of discrete angled rib. The duct used for CFD analysis having the height (H) of 25 mm and width (W) of 300 mm. A uniform heat flux of 1000 W/m 2 was considered for analysis. Roughness was considered at the underside of the top of the duct to have roughened surface while other three sides were considered as smooth surface. 4.2.2 Selection and validation of the model The selection of model is carried out by comparing the predictions by different turbulent models with experimental results available in the literature. The different models namely 80 70 60 50 40 Dittus-Boelter Empirical Relationship Realizable k-epsilon model Renormalization k-epsilon model Standard k-epsilon model SST k-omega model 30 20 10 Figure.2 Discrete angled rib roughness geometry. The 3D solution domain and grid were selected as shown in Fig.3. For the present work, meshing has been done using commercially available software GAMBIT 2.3.16. The size and number of control volumes (mesh density) are user determined and will strongly influence the accuracy of the solutions. After boundary conditions have been implemented the flow and energy balances are solved by an iteration process the decreases the error in the solution until a satisfactory results has been reached. Figure.3 Meshing of the solar air heater duct 4.2 Analysis in FLUENT 4.2.1 Boundary conditions The boundary conditions as shown in Fig.4 as inlet, outlet, heat flux (absorber plate), insulated wall and the fluid zones are defined as per experimental set up. 0 0 2000 4000 6000 8000 10000 12000 14000 16000 18000 20000 22000 Reynolds number,re Figure.5 Comparison between Nusselt number with different models with Dittus-Boelter empirical relationship for smooth surface Renormalization (RNG) group k-epsilon model, Standard k-epsilon model, Realizable k-epsilon model, and Shear Stress Transport (SST) k-omega model have been tested for smooth duct to find out the validity of the models. Nu=0.024Re 0.8 Pr 0.4 (1) Fig.5 shows the variation of Nusselt number with Reynolds number for different models and the results are compared with results computed from the Dittus-Boelter empirical relationship for a smooth duct. It has been observed that the results obtained by Renormalization (RNG) group k-epsilon model are in good agreement with Dittus-Boelter empirical results. It is therefore, for the present numerical study Renormalization (RNG) group k- epsilon model has been employed to simulate the flow and heat transfer. 5. Results and discussion The major objectives of this investigation is to see the effects of discrete angled rib roughened solar air heater duct with the help of Computational fluid dynamics (CFD) software on heat transfer and friction factor. 5.1Temperature Profile (Heat Transfer) Figure.4 Boundary conditions Most of the flow which occurs in practical applications is in general turbulent in nature. In the turbulent region, the velocity of the particles very near to surface becomes almost zero. In this region the particle have very low kinetic energy. This region is called laminar sub-layer. These laminar sub-layer acts as a barrier of heat transfer from heated surface to fluid medium. As shown in the 45

Fig.6 discrete angled ribs are attached underside of the absorber plate these ribs breaking and disturbing the laminar sub layer and flow is wavy flow. drop) very close to each other. It has been observed from fig.8 that Nusselt number ratio (Nu/Nus) increases monotonically with increase in Reynolds number snd the maximum value of Nusselt number ratio corresponding to Reynolds number value of 12000. The secondary flow exerts a measurable effect in disturbing the axial flow profile, which increases the friction coefficient in non-circular duct. The experimental results and CFD results of the friction factor ratio (f/f s ) as a function of discrete angled rib roughness geometry for different values of Reynolds number as shown in the Fig.9. It is observer that the CFD values and experimental values of friction factor (pressure drop) very close to each other. Figure.6. Temperature profile in the roughened solar air heater duct 5.2 Velocity Profile As shown in the Fig.7 velocity profile on the roughened surface and increase the fluid temperature along the length of the duct and outlet of the duct a fluid temperature is maximum. As shown in Fig.7 in the present Computational fluid dynamics (CFD) based analysis angled rib with gap considered underside of the absorber plate. The atmospheric air enters at the rectangular duct and flows under absorber plate which is uniform distribution of heat flux. Creating gap in the inclined ribs allow release of the secondary flow along the rib joins the main flow to accelerate it, which energizes the retarded boundary layer flow along surface resulting in enhancement of heat transfer as shown in Fig.7 the air temperature increase (indicate red color is maximum temperature) along the length of the duct. Figure.8 Variation of Nusselt number ratio with Reynolds number for discrete angled rib geometry Figure.9 Variation of friction factor ratio with Reynolds number Reynolds number for discrete angled rib geometry Conclusions Figure 7. Velocity profile on the smooth surface solar air heater duct The experimental results and CFD results of the Nusselt number ratios (Nu/Nu s ) as a function of discrete angled rib roughness geometry for different values of Reynolds number as shown in the Fig.8. It is observer that the CFD values and experimental values of friction factor (pressure On the basis Computational fluid dynamics (CFD) analysis of heat transfer and friction factor characteristics of the solar air heater duct with discrete angled rib roughness geometry on the absorber plate. The enhancement in heat transfer is found to be increased to 1.45 times that of the heat transfer with that of the heat transfer of smooth surface for discrete angled rib roughened solar air heater. CFD results have been also validated the smooth duct and different CFD model results 46

were compared with Dittus-Boelter empirical relationship for smooth surface. Among all the models used, Renormalization k-epsilon model results have been found to have good agreement. References Prasad, B.N., Saini, J.S., 1988. Effect of artificial roughness on heat transfer and friction factor in a solar air heater. Solar Energy 41, 555 560. Gupta, D., Solanki, S.C., Saini, J.S., 1993. Heat and fluid flow in rectangular solar air heater ducts having transverse rib roughness on absorber plates. Solar Energy 51, 31 37 Cho, H.H., Kim, Y.Y., Rhee, D.H., Lee, S.Y., Wu, S.J., 2003. The effect of gap position in discrete ribs on local heat/mass transfer in a square duct. Journal Enhanced Heat Transfer Aharwal, K.R., Gandhi, B.K.,Saini, J.S., 2008. Experimental investigation on heat-transfer enhancement due to a gap in an inclined continuous rib arrangement in a rectangular duct of solar air heater. Renewable Energy 33,585 96. ASHRAE, Standard, 93 97, 1977. Method of Testing to determine the thermal performance of solar air heater. American Society for Heating, Refrigeration and Air Conditioning Engineering, New York, 1-34. Kumar S, Saini RP. 2009, CFD based performance analysis of a solar air heater duct provided with artificial roughness. Renewable energy ; 34:1285-1291. 47