BubXe: a liquid xenon bubble chamber for Dark Matter detection!

Similar documents
Technical Specifications and Requirements on Direct detection for Dark Matter Searches

Status of DM Direct Detection. Ranny Budnik Weizmann Institute of Science

The XENON1T experiment

COUPP: Bubble Chambers for Dark Matter Detection

DARWIN. Marc Schumann. U Freiburg LAUNCH 17 Heidelberg, September 15,

The Direct Search for Dark Matter

LUX: A Large Underground Xenon detector. WIMP Search. Mani Tripathi, INPAC Meeting. Berkeley, May 5, 2007

Measurements of liquid xenon s response to low-energy particle interactions

DARWIN. Marc Schumann. U Freiburg PATRAS 2017 Thessaloniki, May 19,

Recent results from PandaX- II and status of PandaX-4T

Direct Detection of! sub-gev Dark Matter

SuperCDMS SNOLAB: A G2 Dark Matter Search. Ben Loer, Fermilab Center for Particle Astrophysics On behalf of the SuperCDMS Collaboration

Light Dark Matter and XENON100. For the XENON100 Collaboration Rafael F. Lang Columbia University

Low Energy Particles in Noble Liquids

DarkSide. Bianca Bottino Università di Genova and INFN Sezione di Genova on behalf of the DarkSide collaboration 1

Outline. Dark Matter Physics at SNOLAB: And Future Prospects. Overview of SNOLAB DarkMatter Program. Status of Current Experiments

Status of Dark Matter Detection Experiments

Background and sensitivity predictions for XENON1T

Dark Matter. and TPC Technologies

Background Characterization and Rejection in the LZ Detector. David Malling Brown University IDM 2012 July 25, 2012

Down-to-earth searches for cosmological dark matter

DarkSide new results and prospects

Direct Detection Lecture 2: Current Results

Backgrounds in PICO. Eric Vázquez Jáuregui SNOLAB. AARM Meeting Fermilab; Batavia IL, USA; March 19, 2014

Bubble Chambers for Direct Dark Matter Searches in COUPP

The Search for Dark Matter with the XENON Experiment

Looking for WIMPs A Review

Background Studies for the XENON100 Experiment. Alexander Kish Physics Institute, University of Zürich Doktorandenseminar August 30, 2010 UZH

TWO-PHASE DETECTORS USING THE NOBLE LIQUID XENON. Henrique Araújo Imperial College London

DARWIN: dark matter WIMP search with noble liquids

Direct Dark Matter Search with Noble Liquids

Direct WIMP Detection in Double-Phase Xenon TPCs

Darkside and the future Liquid Argon Dark Matter program

Results from 730 kg days of the CRESST-II Dark Matter Search

arxiv:astro-ph/ v1 15 Feb 2005

SuperCDMS: Recent Results for low-mass WIMPS

Direct dark matter search using liquid noble gases

Nuclear Recoil Scintillation and Ionization Yields in Liquid Xenon

XMASS: a large single-phase liquid-xenon detector

Ge and Dark Matter Searches: CDEX, present and future

PoS(idm2008)010. The PICASSO Dark Matter Search Project. A. Davour for the PICASSO collaboration Queen s University

The next generation dark matter hunter: XENON1T status and perspective

Cryodetectors, CRESST and Background

LZ and Direct Dark Matter Detection

Measurement of the transverse diffusion coefficient of charge in liquid xenon

XENON100. Marc Schumann. Physik Institut, Universität Zürich. IDM 2010, Montpellier, July 26 th,

Dark Matter Search Results from the Silicon Detectors of the Cryogenic Dark Matter Search Experiment

Search for Low Energy Events with CUORE-0 and CUORE

The LZ Experiment Tom Shutt SLAC. SURF South Dakota

Background Neutron Studies for Coherent Elastic Neutrino-Nucleus Scattering Measurements at the SNS

New directions in direct dark matter searches

LZ and Direct Dark Matter Detection. Kimberly J. Palladino May 1, 2018

SIGN: A Pressurized Noble Gas Approach to WIMP Detection

Whither WIMP Dark Matter Search? Pijushpani Bhattacharjee AstroParticle Physics & Cosmology Division Saha Institute of Nuclear Physics Kolkata

XENONNT AND BEYOND. Hardy Simgen. WIN 2015 MPIK Heidelberg. Max-Planck-Institut für Kernphysik Heidelberg

The XENON100 Dark Matter Experiment at LNGS: Status and Sensitivity

DARK MATTER SEARCH AT BOULBY MINE

Searches for Low-Mass WIMPs with CDMS II and SuperCDMS

Current status of LUX Dark Matter Experiment

A survey of recent dark matter direct detection results

Status of the XENON100 Dark Matter Search

Direct Search for Dark Matter

Future DM Direct Detection Experiments

Direct dark matter search using liquid noble gases

The COSINUS project. development of new NaI- based detectors for dark ma6er search. STATUS report Karoline Schäffner

Background Modeling and Materials Screening for the LUX and LZ Detectors. David Malling Brown University LUX Collaboration AARM Meeting February 2011

PoS(TIPP2014)033. Upgrade of MEG Liquid Xenon Calorimeter. Ryu SAWADA. ICEPP, the University of Tokyo

Search for Inelastic Dark Matter with the CDMS experiment. Sebastian Arrenberg Universität Zürich Doktorierendenseminar 2010 Zürich,

Detectors for astroparticle physics

Understanding Ionization, Scintillation Light, and the Energy Scale

The Search for Dark Matter, and Xenon1TP

Dark Matter Search * in China

Direct Dark Matter Searches

June 10 morning session 9:00-

DarkSide-20k and the future Liquid Argon Dark Matter program. Giuliana Fiorillo Università degli Studi di Napoli Federico II & INFN Napoli

Paolo Agnes Laboratoire APC, Université Paris 7 on behalf of the DarkSide Collaboration. Dark Matter 2016 UCLA 17th - 19th February 2016

PoS(EPS-HEP2017)074. Darkside Status and Prospects. Charles Jeff Martoff Temple University

Dark anti-atoms. Quentin Wallemacq IFPA, AGO Dept., University of Liège. CosPa Meeting 19 th of November 2014

Toward a next-generation dark matter search with the PICO-40L bubble chamber. Scott Fallows TAUP2017 Laurentian University 24 July 2017

Darkside-50, DarkSide-20k and the Global Collaboration to reach the Neutrino Floor with liquid argon

Enectalí Figueroa-Feliciano

New Physics Results from DarkSide-50. Masayuki Wada Princeton University on behalf of the DarkSide-50 Collaboration Feb

Esperimenti bolometrici al Gran Sasso: CUORE e CRESST

Direct Detection of Dark Matter. Lauren Hsu Fermilab Center for Particle Astrophysics TRISEP Summer School, June 10, 2014

Recent results from the second CDMSlite run and overview of SuperCDMS SNOLAB project

Shedding Light on Dark Matter from Deep Underground with XENON. Kaixuan Ni (Columbia)

Sensitivity of sodium iodide cryogenic scintillation-phonon detectors to WIMP signals

The XENON Project. M. Selvi The XENON project

Prospects for WIMP Dark Matter Direct Searches with XENON1T and DARWIN

DarkSide-20k and the Darkside Program for Dark Matter Searches

Scintillation efficiency measurement of Na recoils in NaI(Tl) below the DAMA/LIBRA energy threshold

LARGE UNDERGROUND XENON

Do WIMPs Rule? The LUX & LZ Experiments and the Search for Cosmic Dark Matter

Direct Detection in the next five years: Experimental challenges and Phonon Mediated Detectors

Search for low-mass WIMPs with Spherical Detectors : NEWS-LSM and NEWS-SNO

After LUX: The LZ Program. David Malling, Simon Fiorucci Brown University APS DPF Conference August 10, 2011

Dark Matter Searches. Marijke Haffke University of Zürich

The XENON1T Experiment

Measurement of nuclear recoil responses of NaI(Tl) crystal for dark matter search

ω γ Neutral Current Single Photon Production (NCγ) Outline 1. Oscillation physics 2. NOMAD 3. T2K/MINERvA 4. MicroBooNE 5. MiniBooNE+ 6.

Transcription:

BubXe: a liquid xenon bubble chamber for Dark Matter detection Jeremy Mock, on behalf of Cecilia Levy and Matthew Szydagis SUNY Albany

Direct DM Search Today 3 detection channels (light, charge, heat): 2 used at most 3 main experimental techniques (cryogenic crystals, liquid nobles, superheated bubble chambers) LXe TPCs lead the field All experiments lose some information in one way or another. 2

What if you could build a DM detector that has zero loss of information? active on all 3 detections channels LUX/LZ, XENON100/1T/nT, PandaX IONIZATION or CHARGE CoGeNT, DAMIC??? CDMS/SuperCDMS, Edelweiss SCINTILLATION or LIGHT SABRE, DM-Ice CRESST PHONONS or HEAT PICO, SIMPLE Challenge questions: What adaptions can we make to current detectors/technology? Meaning, can we do anything new/interesting without having to start from scratch? Are there ideas from competing experiments that could be merged together to make a better one? 3

The Making Of a New DM Detector LXe detectors: DM detection relies on distinguishing between ER and NR low misidentification probability energy information ERs NRs good energy information 2-18% energy resolution not that good misidentification probability (2 in 10 3 ) ~50% NR efficiency especially bad since NRs lose most of their energy to heat not useable Is there a way to combine LXe technology with something else to make it better? needs to gain heat information needs to gain lower misidentification probability 4

Scintillating Xenon Bubble Chamber A bubble chamber: has heat information has great misidentification probability has no energy information } the perfect complement to a LXe detector <10-10 chance of misidentification plot from PICO NR threshold LXe detector + bubble chamber = LXe bubble chamber has energy information has great misidentification probability active on all 3 channels at a time 5

How do we know it will work? First xenon bubble chamber (Glaser, 1956): bubbles due to gammas in LXe after adding additive to quench scintillation First simulation results: " 1 in a million misidentification probability " a factor 4000 better than LXe detectors bubble formation fraction 10-1 10-2 10 10-4 -5 10 10 1-3 -6 P = 50 psia P = 100 psia P = 130 psia P = 145 psia P = 160 psia 1 MeV e- 1 kev e- 2 kev e- 5 kev e- 10 kev e- 50 kev e- 100 kev e- 1 MeV gamma 1 kev gamma 2 kev gamma 5 kev gamma 10 kev gamma 50 kev gamma 100 kev gamma 0 2 4 6 8 10 12 14 Ec (kev) Looks very promising T=-40 Levy et al arxiv:1601.05131 (JINST 2016) 6

Other Advantages of a LXe Bubble Chamber Challenge questions: What are the limiting backgrounds? How much can shielding help? What about (internal) radioactive backgrounds? Surface events? Comptons? Which technologies suffer from which backgrounds? How can we broaden the kinds of physics these experiments are sensitive to? Sub-keV threshold detector : 100% NR efficiency above threshold no more need for 40-50% fiducialization probe parameter space above neutrino floor at low masses sensitive to coherent neutrino scattering at -40.C and low pressures ~0.5 kevnr the only background left is NR can be shielded against careful choice of material to be fair, (α,n) reactions still a problem 7

How it works: LXe TPC Double phase time projection chamber (TPC) GXe Layer LXe Layer Use 2 detection channels: ionization + scintillation 8

How it works: Bubble Chamber buffer incoming particle heat piezos P v P l = 2 r c camera bubble target piezos Chamber filled with a superheated fluid (above boiling temperature but in a liquid state) Bubble formation if heat deposition > Eth within rc (recoil path length) muon neutron WIMP candidate event Challenge questions: What technologies are needed to probe below the 100 s of kev scale? Are there particularly challenging regions of parameter space? How do we start reaching them? Visible tracks in bubble chamber = possibility to use directionality for ultra-light (relativistic) WIMPs and/or dark photon / dark sector mediators 9

How it works: LXe Bubble Chamber Energy resolution from LXe + discrimination power from BC To prevent nucleation sites Needed to create superheat alternating electric field No loss of information 10

Introducing BubXe A prototype LXe Bubble Chamber at SUNY Albany Thick quartz vessel will contain ~50g of LXe Operated at -40, 220-300 psia Compression valve Decompression valve Pressure Transducer Quartz tube GXe Variable temperature/pressure operation Fine tuning may increase energy resolution Started small Successful leak and compression cycles tests 11

Introducing BubXe Moving to bigger chamber for real tests, first water then LXe Test signal from piezo Camera is good to go VUV MPPC test from Hamamatsu Rough DAQ in place PnID in place Water Cerenkov Bubble chamber should be operational this summer 12

Conclusion 1 Liquid xenon bubble chamber is being developed at UAlbany Many advantages: energy information + amazing discrimination in 1 detector 3 detection channels active including heat no loss of information especially useful at low energies ability to manage operating conditions (temperature and pressure) very easily tunable to different target material useful to have now for feedback on current experiments useful in case of discovery, more information will be needed useful in case of no discovery, a new more sensitive dark matter detector? Status: basic setup in place equipment tested to extreme conditions everything checks out 1st water Cerenkov test expected this summer 1st xenon test expected by the end of the year 13

Conclusion 2 : Final Challenge Question What would constitute a game-changing experiment even if you re not at all sure how to do it? 14

Conclusion 2 : Final Challenge Question What would constitute a game-changing experiment even if you re not at all sure how to do it? A liquid xenon bubble chamber of course 15

Challenge questions Are there particularly well motivated parts of parameter space? What does it take to reach these targets? Are there particularly challenging regions of parameter space? How do we start reaching them? What does it take to make a convincing discovery? Are there brick walls to sensitivity that don t just plague one experiment but are inherent to a common approach? How can we broaden the kinds of physics these experiments are sensitive to? Are there ideas from competing experiments that could be merged together to make a better one? What would constitute a game-changing experiment even if you re not at all sure how to do it? Which models can be probed by direct detect ion that cannot be probed by beam dumps, colliders, and indirect detection? What are the limiting backgrounds? How much can shielding help? What about (internal) radioactive backgrounds? Surface events? Comptons? Which technologies suffer from which backgrounds? Current generation DM-nuclear recoil searches usually rely on two signals to reject signal from backgrounds (e.g. scintillation + ionization in XENON100/LUX, phonons+ionization in SuperCDMS). Can we think of two distinguishing signals for DM-electron recoils? The annual modulation signal is larger for DM-electron scattering that for typical WIMP scattering. If one were to see a signal, what would it take to convince oneself that it is real? How can one verify it? What technologies are needed to probe below the 100 s of kev scale? What adaptions can we make to current detectors/technology? Meaning, can we do anything new/interesting without having to start from scratch? 16